Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
090122_Routine Inspection_20220707
Facility Number 0 Division of Water Resources 0 Division of Soil and Water Conservation 0 Other Agency Type of Visit: ( Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: 0, Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access LORA Region: I NU Date of Visit: 1,1 2 2 Arrival Time: to. oo Departure Time: Farm Name: (,J 0 A W OQ d fa rrn Owner Name: �UV en Th I V m Mailing Address: Physical Address: 0;PS Owner Email: Phone: County: ENTERED TO LASERFIcHE JUL 1 5 2fl22 DVVQRc FAYETTEVILL;= REGIONAL OFFICE Facility Contact: I �j � TitleT Lfl j Phone: F p Onsite Representative: Qrn Certified Operator: C, to F-ufr J ' -�eV �I ` Back-up Operator: Location of Farm: Latitude: Integrator: c m tth f i Certification Number: 782J /✓ I Certification Number: Longitude: Swine Design Current Capacity Pop. Wean to Finish Wean to Feeder +Y 1` Feeder to Finish isiBoD Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Other Design Current Wet Poultry Capacity Pop. Layer Non -Layer Dry Poultry Design Current Capacity Pon. Layers Non -Layers Pullets Turkeys Turkey Poults Other Cattle Design Current Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow Non -Dairy Beef Stocker Beef Feeder Beef Brood Cow Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the State other than from a discharge? ❑ Yes ❑ NA ❑ NE ❑ Yes No ❑ NA ❑ NE ❑ Yes L71 No ❑ NA ❑ NE ❑ Yes VI No ❑ NA 0 NE ❑ Yes No 0 NA ❑ NE ❑ Yes No 0 NA ❑ NE Page 1 of 3 5/12/2020 Continued Date of Inspection: 1 Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? a. If yes, is waste level into the structural freeboard? Structure 1 Structure 2 Identifier: 1 Spillway?: 0 Designed Freeboard (in): Observed Freeboard (in): Structure 3 Structure 4 5. Are there any immediate threats to the integrity of any of the structures observed? (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? ❑ Yes [ ] No ❑ NA ❑ NE ❑ Yes [ No ❑NA ❑NE Structure 5 Structure 6 ❑ Yes ® No ❑ NA ❑ NE ❑ Yes [] No ❑ NA ❑ NE If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? V1 Yes ❑ No ❑ NA ❑ NE e,; 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes / No ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ Yes No ❑ NA ❑ NE maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes No ❑ NA ❑ NE maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes t No ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12. Crop Type(s): 1 e 12,1e) Co'r > O(.P clo13. Soil Type(s): V 1 ' ' i 91,E 1() (V7)7 ('41 NDf1 14. Do the receiving crops differ from those designated in the CAWMP? 15. Does the receiving crop and/or land application site need improvement? 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acres determination? 17. Does the facility lack adequate acreage for land application? 18. Is there a lack of properly operating waste application equipment? Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes ] No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes L J No ❑ NA ❑ NE the appropriate box. ❑ WUP ❑ Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes No ❑ NA ❑ NE ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code El Rainfall El Stocking ❑ Crop Yield El 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes No ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ] No ❑ NA 0 NE BW� Page 2 of 3 5/12/2020 Continued ❑ Yes © No ❑ NA ❑ NE Yes ❑ No ❑ NA ❑ NE ❑ Yes ® No ❑ NA ❑ NE ❑ Yes No ❑ NA ❑ NE ❑ Yes No ❑ NA ❑ NE Facility Number: Date of Inspection: 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes ❑ No ❑ NA ❑ NE 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes [ No ❑ NA ❑ NE the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels Iflac ciftr1/4) ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail provide documentation of an actively certified operator in charge? 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? ❑ Yes If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the n Yes permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Yes ❑ Application Field ❑ Lagoon/Storage Pond D Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? 0 No ❑ Yes 0 No ❑ Yes 0 No ❑ Yes ] No El Yes ❑No ❑NA El NE ❑ Yes No ❑NA ❑NE ❑ NA ❑ NE El No ❑NA El NE El NA ❑NE ❑ NA ❑NE ❑ NA ❑ NE ❑ NA ❑ NE ❑ NA ❑NE Comments (referto question #): E y YES answers artdfor Use drawings of facility to better ex l ations (use additiona N�+ • ost fame prne4 on tc\tc., had citr y11-etic harv-cs+red 1z2 cai►bratton ave this jear 19\1 (2..1.0a 7 mow vvlootA banKS-e;p110i11 fhe toe; f-hv; MI; (qq- 1“-Kil rat tb f piantinq b€n, two F(Q,(4c hay.e. been planted. Reviewer/Inspector Name: ' 1-cp ot Reviewer/Inspector Signature: 16V-eil 01/4- 14t1,4) Phone: IL Il "II (51R , 19 Date: 1. Page 3 of 3 2/4/2015