HomeMy WebLinkAboutWQ0018992_Compliance Evaluation Inspection_20220715DocuSign Envelope ID: 13AE2E14-E6D5-4B1A-BB1 F-DA11 DA73EBA4 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director NORTH CAROLINA Environmental Quality July 19, 2022 Terry Barbour A Place at the Beach - Atlantic Beach Inc DBA Southwinds Condo Assoc PO Box 818 Atlantic Beach, NC 28512-0818 SUBJECT: Compliance Inspection Report Southwinds WWTP Non -discharge Permit No. WQ0018992 Carteret County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Southwinds WWTP on 7/15/2022. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0018992. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Helen Perez with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at helen.perez@ncdenr.gov. ATTACHMENTS Cc: Don O'Mara — electronic copy Upload to laserfiche ODE D.D.nmem m Emimnm.nm INaZ Sincerely, �DocuSigned by: 'TOM- 'Tin...erl oA, fo r "-7F141E73B6F3456... Morella Sanchez -King, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington. North Carolina 28405 910.796.7215 DocuSign Envelope ID: 13AE2E14-E6D5-4B1A-BB1 F-DA11 DA73EBA4 ODE neoenmemmEmimnmenui 0.71\ North Carolina Department of Environmental Quality I Division of Water Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington, North Carolina 28405 910.796.7215 DocuSign Envelope ID: 13AE2E14-E6D5-4B1A-BB1 F-DA11 DA73EBA4 Compliance Inspection Report Permit: WQ0018992 SOC: County: Carteret Region: Wilmington Effective: 10/01/20 Expiration: 11/30/26 Owner : A Place at the Beach - Atlantic Beach Inc DBA Southwinds Condo Assoc Effective: Expiration: Facility: Southwinds WWTP 2008 E Fort Macon Rd Contact Person: Terry Barbour Title: Property Manager Atlantic Beach NC 28512 Phone: 252-247-2318 Directions to Facility: Highway 70 E (Arendell Street) in Morehead City, R onto Atlantic Beach Bridge/Causeway SR1182, L onto East Fort Macon Road System Classifications: SI, WW2, Primary ORC: Donald P Omara Certification: 22801 Phone: 252-247-9167 Secondary ORC(s): On -Site Representative(s): On -site representative Related Permits: Inspection Date: 07/15/2022 Primary Inspector: Helen I Perez Secondary Inspector(s): Donald P Omara Entry Time 11:30AM �DocuSigned by: 4611en, \ene,e5 1D645B4A39694B E... Reason for Inspection: Routine Permit Inspection Type: High Rate Infiltration Facility Status: Compliant Question Areas: ❑ Not Compliant ▪ Treatment Flow Measurement -Effluent ▪ Treatment Flow Measurement -Water Use Records ▪ Treatment Filters ▪ Treatment Influent Pump Station ▪ End Use -Infiltration ▪ Standby Power (See attachment summary) Exit Time: 12:20PM 252-247-9167 Phone: 910-796-7387 Inspection Type: Compliance Evaluation ▪ Treatment Flow Measurement -Influent ▪ Treatment ▪ Record Keeping ▪ Treatment Clarifiers ▪ Treatment Flow Measurement • • Miscellaneous Questions Treatment Barscreen ▪ Treatment Activated Sludge ▪ Treatment Disinfection ▪ Treatment Return pumps Page 1 of 7 DocuSign Envelope ID: 13AE2E14-E6D5-4B1A-BB1 F-DA11 DA73EBA4 Permit: WQ0018992 Owner - Facility:A Place at the Beach - Atlantic Beach Inc DBA Southwinds Condo Assoc Inspection Date: 07/15/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection of the Southwinds WWTF was conducted on July 15, 2022. The purpose of the evaluation was to verify that the facility is operating in compliance with the conditions and limitations specified in Permit WQ0018992. Don and Karrie O'Mara were present during the inspection. This extended aeration treatment plant with a high -rate infiltration, drip irrigation system is permitted for 43,200 gpd. The 2021-2022 flow averaged —7000 gpd during the winter season and—20,000 gpd in the summer. Repairs to the hurricane damaged condo buildings are almost completed. There are plans to replace the EQ tank along with the splitter box and electrical panel in the near future. The plant does not have a chlorine contact chamber and disinfection contact time has to take place in the dosing tank before it discharges to the drip irrigation fields. Staff has been able to adequately disinfect in spite of the challenges. A file review since the last inspection in July of 2020 shows no effluent violations and 3 incidences of slight elevation of TDS levels in MW #1 and MW #3. The facility is compliant with Non -Discharge Permit WQ0018992. Please review the comment sections of the inspection report for more details. Page 2 of 7 DocuSign Envelope ID: 13AE2E14-E6D5-4B1A-BB1 F-DA11 DA73EBA4 Permit: WQ0018992 Owner - Facility:A Place at the Beach - Atlantic Beach Inc DBA Southwinds Condo Assoc Inspection Date: 07/15/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Reuse (Quality) Lagoon Spray, LR Single Family Spray, LR Activated Sludge Spray, LR Activated Sludge Spray, HR Recycle/Reuse Activated Sludge Drip, LR Single Family Drip Infiltration System Treatment Are Treatment facilities consistent with those outlined in the current permit? Do all treatment units appear to be operational? (if no, note below.) Comment: No comment. Treatment Influent Pump Station Is the pump station free of bypass lines or structures? Is the general housekeeping acceptable? Are all pumps present? Are all pumps operable? Are floats/controls operable? Are audio and visual alarms available? Are audio and visual alarms operational? # Are SCADA/Telemetry alarms required? Are SCADA/Telemetry available? Are SCADA/Telemetry operational? Yes No NA NE • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • 000 ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ • ❑ ❑ ❑ • ❑ Comment: The influent pump station is located at the entrance of the condo development. The high level alarm is connected to a telemetry system and notifies ORC by cell phone. Treatment Flow Measurement -Influent Is flowmeter calibrated annually? Is flowmeter operating properly? Does flowmeter monitor continuously? Does flowmeter record flow? Does flowmeter appear to monitor accurately? Comment: Yes No NA NE ❑ ❑•❑ Page 3 of 7 DocuSign Envelope ID: 13AE2E14-E6D5-4B1A-BB1 F-DA11 DA73EBA4 Permit: WQ0018992 Owner - Facility:A Place at the Beach - Atlantic Beach Inc DBA Southwinds Condo Assoc Inspection Date: 07/15/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Treatment Flow Measurement -Water Use Records Is water use metered? Are the daily average values properly calculated? Comment: Yes No NA NE ❑ ❑ • ❑ ❑ ❑ • ❑ Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? • ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ • Does flowmeter monitor continuously? • ❑ ❑ ❑ Does flowmeter record flow? • ❑ ❑ ❑ Does flowmeter appear to monitor accurately? • ❑ ❑ ❑ Comment: The flowmeter was calibrated in April 2022 by Delta Systems Environmental. Standby Power Is automatically activated standby power available? Is generator tested weekly by interrupting primary power source? Is generator operable? Does generator have adequate fuel? Comment: No comment. Treatment Barscreen Is it free of excessive debris? Is disposal of screenings in compliance? Are the bars spaced properly? Is the unit in good condition? Comment: No comment. Treatment Activated Sludge Is the aeration mechanism operable? Is the aeration basin thoroughly mixed? Is the aeration equipment easily accessed? Is Dissolved Oxygen adequate? Are Settleometer results acceptable? Is activated sludge an acceptable color? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • Yes No NA NE ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ Comment: A settleometer test is done weekly along with monitoring pH, DO and chlorine for process control. Treatment Clarifiers Are the weirs level? Are the weirs free of solids and algae? Yes No NA NE ❑ ❑ ❑ • • ❑ ❑ ❑ Page4of7 DocuSign Envelope ID: 13AE2E14-E6D5-4B1A-BB1 F-DA11 DA73EBA4 Permit: WQ0018992 Owner - Facility:A Place at the Beach - Atlantic Beach Inc DBA Southwinds Condo Assoc Inspection Date: 07/15/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the scum removal system operational? Is the scum removal system accessible? Is the sludge blanket at an acceptable level? Is the effluent from the clarifier free of excessive solids? Comment: No comment. • ❑ ❑ ❑ • ❑ ❑ ❑ Treatment Return pumps Yes No NA NE Are they in place? • ❑ ❑ ❑ Are they operational? ❑ ❑ ❑ • Comment: No comment. Treatment Filters Is the filter media present? Is the filter media the correct size and type? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids? Is the mud well free of excessive solids and filter media? Does backwashing frequency appear adequate? Yes No NA NE ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: The dual tertiary filters consists of a course screen. Staff backwashes units manually about once a week when accumulation of solids reaches -1 inch. Treatment Disinfection Is the system working? Do the fecal coliform results indicate proper disinfection? Is there adequate detention time (>=30 minutes)? Is the system properly maintained? If gas, does the cylinder storage appear safe? Is the fan in the chlorine feed room and storage area operable? Is the chlorinator accessible? If tablets, are tablets present? Are the tablets the proper size and type? Is contact chamber free of sludge, solids, and growth? If UV, are extra UV bulbs available? If UV, is the UV intensity adequate? # Is it a dual feed system? Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? If yes, then is there a Risk Management Plan on site? If yes, then what is the EPA twelve digit ID Number? (1000- - ) Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ Page5of7 DocuSign Envelope ID: 13AE2E14-E6D5-4B1A-BB1 F-DA11 DA73EBA4 Permit: WQ0018992 Owner - Facility:A Place at the Beach - Atlantic Beach Inc DBA Southwinds Condo Assoc Inspection Date: 07/15/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine If yes, then when was the RMP last updated? Comment: The plant does not have a chlorine contact chamber. Effluent from the chlorinator flows directly into the dosing tank. This design is challenging for staff to allow enough contact time before discharging to the infiltration fields. A review of fecal results shows that the disinfection process is adequate. Record Keeping Is a copy of current permit available? Are monitoring reports present: NDMR? NDAR? Are flow rates less than of permitted flow? Are flow rates less than of permitted flow? Are application rates adhered to? Is GW monitoring being conducted, if required (GW-59s submitted)? Are all samples analyzed for all required parameters? Are there any 2L GW quality violations? Is GW-59A certification form completed for facility? Is effluent sampled for same parameters as GW? Do effluent concentrations exceed GW standards? Are annual soil reports available? # Are PAN records required? # Did last soil report indicate a need for lime? If so, has it been applied? Are operational logs present? Are lab sheets available for review? Do lab sheets support data reported on NDMR? Do lab sheets support data reported on GW-59s? Are Operational and Maintenance records present? Were Operational and Maintenance records complete? Has permittee been free of public complaints in last 12 months? Is a copy of the SOC readily available? No treatment units bypassed since last inspection? Yes No NA NE • ❑ ❑ ❑ ❑ ❑ ❑• ❑ ❑ ❑• • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑• • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑•❑ ❑ ❑•❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ ❑ ❑ ❑• ❑ ❑ ❑• ❑ ❑ ❑• • ❑ ❑ ❑ ❑ ❑ ❑• ❑ ❑ • ❑ ❑ ❑•❑ • ❑ ❑ ❑ Comment: A review of records since the last inspection in 2020 show a slight elevation in TDS for MW#1 and MW#3 but facility is in a barrier island environment. There have been no effluent violations. End Use -Infiltration # Is the application High Rate or Low Rate? Are buffers maintained? Are any supply wells within the CB? Yes No NA NE High Rate ❑ ❑ ❑ • Page6of7 DocuSign Envelope ID: 13AE2E14-E6D5-4B1A-BB1 F-DA11 DA73EBA4 Permit: WQ0018992 Owner - Facility:A Place at the Beach - Atlantic Beach Inc DBA Southwinds Condo Assoc Inspection Date: 07/15/2022 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are any supply wells within 250' of the CB? Is municipal water available in the area? Are GW monitoring wells required? Are GW monitoring wells located properly w/ respect to RB and CB? Are GW monitoring wells properly constructed, including screened interval? Is a usable green area maintained? Is the disposal site acceptable? Is the distribution equipment acceptable? Is the disposal site free of ponding? Is the disposal site free of breakout? Are the disposal sites free of solids, algae, etc.? Do the records show that the fields are properly maintained? Are the disposal sites free of vegetation? Do any surface water features appear to be adversely impacted by GW discharge? No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ Comment: Drip fields are well maintained. Public access is restricted by a rope security fence and posted signs. The drip fields are covered in a landscaping cloth with rubber tire mulch to prevent vegetation growth. Page 7 of 7