Loading...
HomeMy WebLinkAboutNCC222434_Site Plan or Location Map_20220715VICINITY MAP NOT TO SCALE LEGEND: "MZ ECM -EXISTING CONCRETE MONUMENT EIP Oa EIP-EXISTING IRON PIPE EPKO EPK-EXISTING PK NAIL ERBO ERB-EXISTING REBAR ERS0 ERS-EXISTING RAILROAD SPIKE c COMPUTED POINT N/F - NOW OR FORMERLY R/W - RIGHT OF WAY PROPERTY LINE — oPL — — — OLD PROPERTY LINE ADJACENT PROPERTY LINE RIGHT-OF-WAY - — — — -SETBACK LINE ss SANITARY SEWER LINE so STORM DRAINAGE w WATER LINE —GAS UNDERGROUND GAS LINE OVERHEAD UTILITY PERMANENT EASEMENT X WIRE FENCE WOODEN FENCE TREE LINE 265 MAJOR CONTOUR 262 MINOR CONTOUR x 268.13' SPOT ELEVATION -q� BENCHMARK SIGN SIGN 9 BOLLARD * LIGHT POLE PPS UTILITY POLE C GUY WIRE ❑T TELEPHONE PEDESTAL N WATER VALVE FIRE HYDRANT ❑❑ WATER METER O WATER SPIGOT MONITORING WELL @ WELL ® CATCH BASIN ® DROP INLET n SANITARY SEWER MANHOLE oco CLEANOUT HARDWOOD TREE 0 GRAVEL ASPHALT 0 CONCRETE BUILDINGS SITE NOTES 1. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY THE GENERAL CONTRACTOR. 2. EXISTING UNDERGROUND UTILITIES ARE SHOWN ONLY WHERE EVIDENCE COULD BE FOUND TO VERIFY LOCATION. PRIOR TO CONSTRUCTION OR EXCAVATION OF THE SITE, THE GENERAL CONTRACTOR SHALL VERIFY ALL UTILITY COMPANIES TO VERIFY THE LOCATION OF THEIR RESPECTIVE UTILITIES. ALL DAMAGE INCURRED TO EXISTING UTILITIES DURING CONSTRUCTION SHALL BE REPAIRED AT THE GENERAL CONTRACTOR'S EXPENSE. 3. ASPHALT AND BASE TYPE SHALL BE PER THE DETAILS. 4. HANDICAP RAMPS, SIGNAGE AND PARKING SPACES SHALL BE PROVIDED BY THE CONTRACTOR AND INSTALLED PER FEDERAL ADA AND LOCAL REQUIREMENTS. 5. ALL DIMENSIONS ARE TO THE BACK OF CURB OR TO THE FACE OF SIDEWALK UNLESS OTHERWISE NOTED. 6. ALL RADII ARE 5' UNLESS OTHERWISE NOTED. 7. PARKING STALLS MUST BE STRIPED WITH A 4 INCH CONTRASTING STRIPE (YELLOW ON CONCRETE AND ASPHALT PARKING LOT). 8. HANDICAP PARKING SPACES ARE TO BE DESIGNATED BY BLUE STRIPING AND EITHER A BLUE SYMBOL ON A WHITE BACKGROUND OR A WHITE SYMBOL ON A BLUE BACKGROUND. ALL HANDICAP PARKING STALLS REQUIRE THE INSTALLATION OF THE PROPER SIGNAGE. 9. ALL PARKING SPACES ARE TO BE LAID OUT IN ACCORDANCE WITH THE SITE PLAN DIMENSIONS. 10. ALL WASTE MATERIAL SHALL BE DISPOSED OF OFF -SITE IN ACCORDANCE WITH STATE AND LOCAL LAWS AND REGULATIONS. 11. ALL SITE IMPROVEMENTS SHALL BE INSTALLED PER CITY OF FAYETTEVILLE AND STATE REGULATIONS. 12. ALL EXISTING UTILITIES, FENCES, AND OTHER STRUCTURES IMPEDING CONSTRUCTION SHALL BE REMOVED OR RELOCATED. N /F ELIZABETH CAIN BEATTY DB 753, PG 155 / FENCE 6' VEGETATED` SHELF / gyp. / ��4 F / O �9 / 'LO S / J'8 09A F \ 06,E 'A / c�j / \ �17 O / \ N /F \ JENNIFER V. EVANS / DB 11343, PG 65 \ PB 48, PG 55 r16\ / / \ N /F \ / / JEONG C. KI WIFE, AN SOON KIM \ DB 8828 PG 533 SITE DATA DEVELOPER RHETSON COMPANIES, INC MAILING ADRESS 2075 JUNIPER LAKE ROAD CITY, STATE WEST END, NORTH CAROLINA 27376 REID NUMBER 0409-22-2142 & 0409-21-3977 TOTAL LOT AREA 71,874 SF (1.88 AC) AREA TO BE DEVELOPED 71,874 SF (1.88 AC) EXISTING ZONING CC EXISTING USE UNDEVELOPED/VACANT PROPOSED USE RETAIL DISTURBED/DENUDED AREA 2.3 AC SETBACKS REQUIRED: FRONT 25 FT SIDE 3 FT/ 15 FT ABUTTING SINGLE FAMILY USE REAR 3 FT/ 20 FT ABUTTING SINGLE FAMILY USE OPEN SPACE: REQUIRED 3,594 SF PROPOSED (TOTAL) 6,529 SF USABLE 4,800 SF PARKING: REQUIRED (INCLUDING HANDICAP) 36 PROPOSED (INCLUDING HANDICAP) 36 PROPOSED HC SPACES 2 \, O \ \ N 492,316.243 ♦ E 2,002,274.101 NC GRID NAD 83 10' ROW _ ♦� RR (2011) SHARED ACCESS TBM 4D PK NAIL #1 N 492,294.032 E 2,002,246.771 ELEV 270.86 NC GRID NAD 83 (2011) NAVD 88 \ PB 48, PG 55 0 a \ / O 1" EIP s9, \ (PINCHED) / / \ / 1" EIP / (PINCHED)O / / / / / / / / / \ 18 \ N /F \ HILLARIE A. SAUL-ROTHMAN & DAVID JAY ROTHMAN \ DB 8955, PG 819 PB 48, PG 55 \ _1_9 N /F \ / AE CHA ROUTH \ / DB 4342, PG 747 PB 48, PG 55 \ / \ -� WHITE MINI / SKIP LINE 30" CONCRETE , \VARIABLE WIDTH \ / S SIDEWALK EASEMENT \/ RRC `gyp. 2' LAP JOINT. MILL TO A DEPTH OF 2" OF \ 15' STREET RELOCATE POWER \ BUFFER �O POLE `SA RIGHT TURN LANE \♦ 100' STORAGE \ 50' TAPER \ ®� REMOVE 257 LF moo- OF CURB & GUTTER \� WHITE EDGE \\ LINE \ / ' \ LIGHTED PYLON SIGN W/ R5' UNDERGROUND ELECTRICAL \ / �\ L9 1" EIP R5' O,� \(PINCHED) x` HC DIRECTION CURB RAMP �\ 5/ O�O / ERB 96 \ \ 6' ��p /z� \ �Q HC DIRECTION R35' CURB RAMP 1 \ R5' �! 4' CONCRETE VALLEY GUTTER \\ HC DIRECTION oxCURB RAMP \ \ \ \ \ f 2 1 \ N /F \ WAYNE R. MOORE \ DB 4589, PG 763 \ PB 29, PG 20 N /F \ / RADIANCE GROUP LLC \ DB 10434, PG 658 PB 29, PG 20 \ N 492,010.382 E 2,002,531.600 NC GRID NAD 83 (2011) 5/8" ERB N /F WAYNE R. MOORE DB 4589, PG 763 PB 29, PG 20 ♦ ♦ NCDOT R/W ECM _4 GRAPHIC SCALE 30 0 15 30 60 120 ( IN FEET ) 1 inch = 30 ft. 4 4Dsite solutions civil engineering I land surveying 409 Chicago Drive, Suite 112, Fayetteville, INC 28306 office 1910-426-6777 fax 1910-426-5777 license number I C-2354 wwwAD site solutions.com ••••• ••• • 4� SEA • 0274 CC)1 1111g���``` U6-U.2-22 REVISIONS PROJECT NAME FAYETTEVILLE YADKIN ROAD DOLLAR GENERAL SITE PLAN CLIENT RHETSON COMPANIES, INC. 2075 Juniper Lake Road West End, North Carolina 27376 Phone: (910) 944-0881 PROJECT INFORMATION DESIGNED BY: SCOTT DRAWN BY: SCOTT CHECKED BY: CHRIS PROJECT NUMBER: 1828 DRAWING SCALE HORIZONTAL: 1 "=30' DATE RELEASED J U N E 2, 2022 SHEET NUMBER C-200