HomeMy WebLinkAboutWQ0041329_Revised App_20220714State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 06-21 & SUPPORTING DOCUMENTATION Application Number. W 0 U 0 �{ + A A010 be completed by Dwtt) A11 items must be completed or the application wjll be returned I. APPLICANT INFORMATION: 1. AppIicarifs name: Town of Fuquay-Varina (company, municipality, HOA, utility, etc.) 2. Applicant type. ❑ individual ❑ Corporation ❑ General Partnership ❑ Privately -owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: per j,�_ N(:At. 0 1' -Q1 M6(b} Michael Wagner Title: Public Utilities Director l�TC Dept of Environmental Quality 4. Applicant's mailing address: 401 Old Honeycutt Road City:1~uquay-Varina State: NC Zip: 27526 MAY ) 8 2V2 5. Applicant's contact information: Phone number: (U9} 5677-3911 Email Address: mm= guav-varina.ore Raleigh Regional Office If. PROJECT INFORMATION: 1. Project name: Arlington Meadows 2. ApplicationlProject status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ0041329 and issued date: 12/20/19, For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new constriction, but part of a roaster plan, provide the existing permit number. WQ00 3. County where project is located: Wake 4. Approximate Coordinates (Decimal Degrees): Latitude: 35,560908° Longitude:—78.7859$5° 5. Parcel ID (if applicable): 0665299258, 0665395480. (or, Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer. Kir y�;�gI, LicenseNumber14,Q23 NOTE: Truehomes USA has assigned Firm: Bass, Nixon a Kennedy, Inc. BNK. Inc as the new Engineer of Recor Mailing address: 6310 Chapel Hill Road, Suite 250 for Arlington Meadows. Spaulding -Norris, PA, original Engineei City: Raleigh State: NC Zip: 27607 of Record has also given BNK, Inc. Phone ntmnber:1919_851-4422 Email Addtesss&►bie.Bell(r�bnlrinc.com permission to use their Arlington Meadows approved plans for this IV. WASTEWATER TREATMENT FACII.ITY (WWTF) INFORMATION: submittal 1. Facility Name: Harnett Co. WWTP Permit Number: NC 0021636 Owner Name: Harnett County V. RECEIVING DOWNSTREAM SEWER INFORMATION: l . Permit Number(s). WQ0040793 2. Downstream (Receiving) Sewer InformationL$ inch ® Gravity 0 Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00193 Owner Name(s): Town of Fuquay-Varina FORM: FTA 06-21 Page I of 5 NIL GENERAL RF:QVIREMENTS 1. ]f the Applicant is a Privately -Owned Public Utility. has a Certlfieatc of Public Con entence and Necessity been attached? ❑ Yer ❑ No ®NA 2. II'the Applicant is a Dc+eloper of lots to be sold. has a IJl ;'ell=pc r t)l rr;t: nrn �l :� >n. n7c rir e i [ �It:b3: I)IL? been attached" ❑ Yeti ❑ No ® N/A 3. If the Applicant is a Home. Property Owners' Association, has an I lQA I OA 4.111cr;OMILd a�!rr<•inerit (I ( fl :NJ. t it , - and supplementary documentation as, required by 15A NCAC 02T,01 15(c) been attached? ❑ Yes [:)No ® N- A 4. Origin ofwastewater: (check all that apply); ® Residential (Individually Owned) ❑ Retail (store;, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation+service ❑ Ilotei and:or Motels ❑ School preschool : day care ❑ Medicdi - dental +eterinary facilities ❑ Swimming PooF'Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming PoolTilter Backwash ❑ Businesses oflices ; factories ❑ Nursine, Ilonic El Other (I xplain in Attachment) 5. Nalure of wastewater ' 100°o Domestic _0, Commercial _',%) Industrial ('' : I ' v ' . .. . ) ll'Industrial, is there a Pretreatment Program rn effect? ❑ Yes❑ No 6. Has a Ilow reduction been approt cd under I .. .. , 1 ' : 1 , , ' 0 ® Yes ❑ No If Wes, provide a copy of flo" reduction approval letter with this application 7. Summarize wastewater generated by prt>icct. Establishment Type (see 02T.0114(I)) Daily Design Flolr '''' -No. of Units Flo►+ Sinr,le Family Units (Phases 7- of 10 300 gal:unit 2U C,.itOU GPD 225 gal'untl 62 13.950 GPD Single Family Units (Phases 1-6) 300 gal. unit 90 27,000 GPD ('al,, Gill) gal' {iPD gal: GPI) Torul 4 6,9 50 Ml1) a See • '�'. 1. . . :I . . for caveats to wastew ater design flow rate. (i_e.. minirnunl now per dwelling. proposed unknown non. -residential development uses; public access facilities localed near Ingh public use area;_ and residential property located south or east of tlic llilaillic liltracclastal Water+ay to be used as,,acation rental.,, as defined b Per I SA NCAC" 021 .01 14(c). design flornn- rater• for "lablishment> nol identified [in table i NcAC 02 1.01 1 ] shall be detennined using available flow data. water using fixture,, occupancy or operation pallenls, and other mea,ured data. 8. Wastewater generated by project- 19.950 GPD {per ' .A N('A(. (!2 t .11114) Do not include future tlo++s or preWtously permitted allocation: [1' pcnilittcd f1onis zero, please itidlcatc �+liy: ❑ Punnp Station. Force Main air Gra+ity Sewer where flow will he pernimed in whsequent permits that connect to this line. Please provide supplementary infonnation indicating. the approximate timel-rame for perinunng upstream sewers Willi flow, ❑ IFlow has already been allocated in Pennit Number. Issuance Late: ❑ Rehabrinanon or replacement of'existing sewers with no new flow expected ❑ Other (Explain). FOR11: 1=1 A 06-21 Page 2 01' 5 N 11. GRAN! I-1 , Sls vp.R DE.SICN CRITERIA (If Applicable) - 021 .0.10� &III)( (Gr711 i11 firs%t'rst; I Summarize gill ity sewer to be pennitted: Size (inches) Length (feet) Material R (I'll. 7-to)1937 PVC 801h.7-10 2379 PVC-C900 R(Ph. 7-10 231) 8011.1-6) 7313 i Section 11 & III of, the MI)C for Penuitting of'Gravity Sewers contains mforinatio n related to design criteria Section III contains inibmiation related to minimum .~lopes for gravity sewer(s) Oversizing Iines to meet minimum slope requirements is not allo,*ied and a violation of file NIDC %'Ill. PUMP STATION DESIGN CRITERIA (if Applicable) — 021 .1015 & NIl)t (Pumt� titaliun, I n�rt 1laiu� PROVIDE A SI-I'ARA] h COPY 01: THIS PAGE FOR EACII PUMP STATION INCLUDED IN THIS PROJECT' I . Pump station number or name: N A 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Total number of pump~ at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) r I his should reflect the total GPM for the pump station A till the largest pump out of' sera ice. 4. Operational point(s) per pump(s): gallon, per minute (GPM) at __ ficl total dynalmc head (7 DI1) 5. 5titlinuirize till' lilrce plain to be permitted (for this Pump Station): Size (inches) Length (feet) Material i Wally portion of the force main is less than 4-inches in diameter, please identify (he method of solid, reduction per st-1DCI'SE�M Section 2.01 C:.I.b. ❑Grinder Pump ❑ (\Icchanlcal Hap Soren ❑ C)thcr (please sperlfj } _ 6. 1'rn\ er reiiabilita in accordance with . , ❑ Standby power source or ❑ Standby pump Mu.t have autonnalic activation and telemetry - 15A 1-CAC' o2'l' 0105(h)(1)([i) % Required for all pump stations with an average daily flop- greater Than or equal io 15-000 gallon; per day Must be permanent to facility and may not be portable Or if -tie pump station has an average daily flow leas than 15,000 gallons per day 15A NCACO2"1.0Y15(h)(I )(C)- ❑ Portable power source with manual actnelion. quick-coneneciion receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telenlorv: include documentation that the portable source is owned or contracted by the applicant and is compatible Nl nth the .lation. If the portable power source or pump is dedicated to multiple punnp station.-,. :111 e%alualion of till the pump stations storage capaciliv,; kind the rotation schedule of the portable power source or pump, imluding travel timc6ame,. shall be prm ided a, part of illic pemut application in the ca:c of a muhiple station power outage - FORM: F I'A 06-21 Page ; C,I,; IX. SETBACKS & SEPARATIONS — (029.0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations/alternatives found in .1 1y(_ AQ2 ® Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be nrovided for sewer systems - Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 2Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 2Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches If noncompliance with 2, 7.03o5(Q or (" see Section XI of this application * l S A N ±[ _021.gRXj ] contains alternatives where separations in 0ZI .03W cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's H.L. urlate Woter 9-1# sitic, ,.s webr5y 2. Does this project comply with the minimum separation requirements for water mains? ❑ Yes ❑ No ® NIA ➢ if no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ❑ Yes [--]No ® N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ Seethe Division's dni ft separation Muircnwms for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Cape Fear ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC=.. 02 B -0200 ® Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 28.0202 5. Does the project require coveragelauthorization under a 404 Nationwide/individual permits ® Yes ❑ No or 401 Water Quality Certifications? ➢ Please provide the permit numberlpernitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15 A l CM, 021, 0105(c)(6 (additional permits/certifications)? ® Yes ❑ No Per 15A W'AQ 02T.0105(c)(6 ), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?' ❑ Yes ® No Per 15A NCAC 02]J[-0.4(] "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to shmnbanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through intert'erence/conilict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I SA IVCAL 02T the M--i kn-Y1g fXM- ao Criteria for the Per �� io aotl FcrrgL. N1pi , !2tc 4i version), and the Gravity Sewer Minimum D sign Qjlaria rlalcse_ vet Jc as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10.14) and supporting documents for review to the Central Office. Agplroval of the request„a be issued concurregay with Q1 approval of thS perinit, and Proieca-muiring a v v a be SUWILt to to revigff MMes. For ro reguiting two or MM variances or where the variance Is deWmIned by the DWAgn to be a ShMilicanl porch of the nrolect. the full tthWcgl review is_rcoulred. 2. Professional Engineer's Certification: 1, KidY L Bell, dr. attest that this application for Arlington Meadows Phases ?-10 (Professional Engineer's name from Applications Item Ill. 1,) (Project Name from Application Item 11.1) has been reviewed by me and Is accurate, complete and consistent with the Information supplied In the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Mlinirnuflt Vrsistn i:ritcs}a.& Gravity Seven; •t ► qpj, and the imurrs V i jta C'rit_e_ria for the Fast-'i`rack Fcmti0ir� 9f NMV StatiUrin andand Firrce Main$_(iatest vcttliyn}. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (2) NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: 0-11 3. Applicant's Certification per 15A NCAC 02T .0106(b): 1, Michael Wagner, attest that this application for Adinaton Meadows Phases 7-10 (Signature Authority Name from Application Item 1.3.) (Project Name from Application Item 11.1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes I143_2I5.6A and .I43 715.6b, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature• Date: 04/27/2022 FORM: FTA 06-21 Page 5 of 5 &11cPl orEnviranmental Quality State of North Carolina VV Ralcigh Regional Department of Environmental Quality D. off, -Ca Division of Water Resources [ OSIon of Wasel Resources Flow TrackingtAcceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Town of Fuquay-Varina Project Name for which flow is being requested: Arlin on Meadows Subdivision More than one ME may be required for a single project if the owner of the WNITP is not responsible for all pump stations along the route of the proposed waste+vater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett Regional WWTP b. WWTP Facility Permit #: NCO021636 Al! flows are its MGD c. WWTP facility's permitted flow 7.5 MGD Fuquay-Varina Allocated Flow 2.60 MGD Lillington Allocated Flow 1.20 MGD Angier Allocated Flow 1.008 MGD d. Estimated obligated flow not yet tributary to the WWTP 2.504 MGD FV Obligated Flow NYT 0.655 MGD Lillington Obligated Flow NYT 0.237 MGD HC Obligated Flow NYT 0.965 MGD Angier Obligated Flow NYT 0.647 MGD e. WWTP facility's actual avg. flow 5.087 MGD FV Actual Flow 1.231 MGD Lillington Actual Flow 0.642 MGD HC Actual Flow 2.568 MOD Angier Actual Flow 0.646 MGD f Total flow for this specific request g. Total actual and obligated flows to the facility FV Actual Avg. + Obligated Flow Lillington Actual Avg. + Obligated Flow HC Actual Avg. + Obligated Flow Angier Actual + Obligated Flow h. Percent of permitted flow used 0.020 MGD 7.611 MGD 1.906 MGD 0.879 MGD 3.533 MGD 1.293 MGD 101.48%* *A PER to expand the NHRWTTP treatment capacity has been completed and design of the expansion is currently underway. Page 1 of 4 FTSE 06-13 1I. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)-(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm 1 pf), Daily Flow, Daily Plow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** SLS 120 14.4 5.76 2.819 2.382 5.201 0.559 _ * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): North Harnett Regional WWTP Downstream Permit Number: NC0021636 Ill. Certification Statement: 1 .� r certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates accept ce of this wastewater flow. Signing 4jTicial Signature Date Page 2 of 4 FTS E 06-13 r Dept n I' E n viran mental Quality State of North Carolina MAY � ?� Department of Environmental Quality DWRDivision of Water Resources Division of Water Resources Ralcigh Rcgion i j' . eking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Town of Fuguay Varina Project Name for which flow is being requested: Arlington Meadows Phase 7-10 More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater,Jlow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett Regional WWTP b. WWTP Facility Permit #: NCO021636 � c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility It. Percent of permitted flow used All flows are in MGD 2.6 .655 1.231 .019 1.886 72.5% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow" Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Gravity * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pi) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): ToFV to KennethCreek/NeilsCreek Inter Downstream Permit Number: WQCS00193 to WQ0028647 Page l of 6 FTSE 10-18 I11. Certification Statement: I Michael Wagner certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing OjJIcial Public Utilities Director Title of Signing Official Date Page 2 of 6 FTSE 10-18 BASS, NIXON & KENNEDY, INC., CONSULTING ENGINEERS 6310 CHAPEL HILL ROAD, SUITE 250, RALEIGH, NC 27607 919/851-4422 FAX 9191851-8968 www.bnkinc.com Arlington Meadows Phases 7-10 Project Narrative: The proposed Arlington Meadows Development is located at 1401 Angier Road, Fuquay-Varina, NC 27526. The site is approximately 3,200 LF south of the intersection of S. Judd Parkway SE and Angier Road. The ultimate project includes infrastructure construction for 172 Single Family Residential Units. The enclosed permits are for infrastructure construction associated with Phases 7-10 (81 units). The homes in Phases 7-10 will be served by 1,937 LF of 8" PVC, 2379 LF of 8" PVC-C900, and 239 LF of DIP sewer mains with a proposed flow of 19,950 GDP. A sanitary sewer outfali will be constructed within acquired easements through the Niels Crossing Subdivision and connect to a proposed sewer outfall currently under construction by the adjacent Geneva Subdivision. Please see enclosed Utility Plans. Attached Information: This package includes the following: 1. This Cover sheet with Narrative, Maps 2. FTA 06-21 (Instructions) 3. FTA 06-21 (Fast Track) 4. FSTE 10-18 5. FSTE 06-13 6. Existing Permit 7. $480.00 Check (#3291) Project Schedule: Construction of Arlington Meadows Phases 1-6 are complete and were previously permitted under WQ 0041329 dated December 20, 2019. Infrastructure construction for phases 7-10 is estimated to be complete by April 2023. Complete build -out of phases 7-10 and issuance of certificates of occupancy is expected to be complete by April 2024. Change of Engineer of Record: Please note that Arlington Meadows (Phases 1-10) was designed by Thomas Spaulding, PE with Spaulding & Norris, PA. The developer of record, True Homes USA decided to change project engineer for the remaining Phases 7-10 to Kirby R. Bell, Jr. PE with Bass, Nixon & Kennedy, Inc. Permission was granted by Thomas Spaulding to allow Bass, Nixon and Kennedy, Inc. to use plans designed by him. v ' 1 -:W r PHASE, PROPOSED SFWER r EWER (P)(r Y waits RD SCALE 1.24 Oa0 FUQUAY-VARINA, NC 1 0.5 0 KILa+lUM 1 -- _ I 2016 1 loon SOD 1 O.S 0 METERS O Iwo 7A0D 1 1ILM low 0 1000 2OW 30D0 1000 6000 7D00 woo 9000 10000 - . ,. - .... GTON S PREPARED R: TRUE HOMES � L7�V111 \ �.�1J17iJO � � 2849 BRIXOhRIDGE CENTRE DR FUQUAY-VARAYA. wace COunnv, nra�rN c ouerA SEWER PERMIT SUITE 104 DATE : 11/21/2019 USGS QUAD 'FUQUAY-VARINA S&N FIRM CERT. /: C-1875 PROJECT ENGINEER: �+ THOMAS J. SPAULDING PROJECT CARD DESIGNER: THE SPAULDIN_G GROUP, PA BD Fr`"""`a tows/ tna,ararrna 16u! R.r�bNC 7m PROJECT SURVEYOR: � ROBINSON k PLAN E, PLC FUTURE SEWER (PHASE 7-10) �— EXISTING SE1 (BY OTHERS) ARUNGTON MEADOWS FUOUAY-VARINA WAKE COUNV7Y, NORTM CARMNA SEWER PERMIT STREET LEVEL MAP s THE SPAULDING GROUP, PA AMB RE FOREST DRIVE i PWF4 )PH AS8.E 2 i I PKW 5 00 Irv.. � PHASE 8� PROPOSED SEWER (PHASE 1-6) RUE HOMES ,849 BREKONRIDGE CENTRE 01 PUITE 104 IDNROE. w 28110 DATE : 11/21/2019 S&N FIRM CERT, J. C-1875 PROJECT ENGINEER: THOMAS J. SPAULDING PROJECT CADD DESIGNER: BD PROJECT SURVEYOR: ROBINSON do PLANTE. PLC PROPOSEDI SITE FAST TRACK SEWER REPORT ARLINGTON MEADOWS PHASES 7 - 10 FUQUAY-VARINA, NC Wake Co. Prepared by: Bass, Nixon & Kennedy, Inc. 6310 Chapel Hill Rd., Suite 250 Raleigh, NC 27607 May, 2022 NC Dept of Environmental Quality MAY 18 2M Raleigh Regional Office '+„rv711trltrpr, .��``� CAR '''• CC `�,oFSSlp�iti 3 .GIN .R�.• l . 8Ev •�• �� `31