Loading...
HomeMy WebLinkAboutNCG100110_2021 DMR_20220429CERTIFIED MAIL, RETURN RECEIPT REQUESTED Date: Ltr -- Washington Regional Office Attn: Central Files 943 Washington Square Mall Washington, NC 27889 RE: LKQ East Carolina LaGrange, NC Permit # NCG100110 2021 Fourth Quarter Discharge Monitoring Report Dear Sir/Madam: Please find attached the 2021 Fourth Quarter Stormwater Discharge Monitoring Report (DMR) for the LKQ East Carolina facility located in LaGrange, North Carolina. This submittal covers the reporting period October 1st to December 315t, 2021. No discharge occurred during this monitoring period. A copy of the DMR was also uploaded electronically as required. Please call me at (252) 566-3167 or Brandon Walsh at (615) 477-9833 if you have any comments, questions, or concerns about the information presented in this submittal. c P. Attachment NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG100000 Used hilotor Vehicles Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the a ro riate DEMLR Re Tonal Office. Certificate of Coverage No. NCG10 0110 Person Coilecting Samples: Jerry Smith Facility Name: LKQ East Carolina Laboratory Name: Eurofins TestAmerica, Savannah Facility County: Lenoir Laboratory Cert. No.: 490 Discharge during this period: i]Yes E] No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sam le Qerjgd for any benchmark exceedances?Q Yes Q No If so, which Tier (I, II, or III)? A copy of this DMR has been uploaded electronically via htt s: edocs.deg. nc. ov Forms 5W-DMR ✓ Yes 0 No Date Uploaded: Analytical Monitoring Requirements for CDutfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 001 Outfall 002 Outfall 003 Outfall Outfall Code N/A Receiving Stream Class C C C N/A Date Sample Collected MM/DD/YYYY 3/14/22 3/16/22 3/16/22 46529 24-Hour Rainfall in inches 0.75 0,75 0.75 C0530 TSS in mg/L (100 or 50*) 3.7 61 25 pH in standard units (6.0 —9.0 FW, 00400 6.8-8.5SW) 7.01 7.01 7.01 Chemical Oxygen Demand in mg/L 00340 (120) 36 Lead, total recoverable (as Pb) in 01051 mg/ L (0.075 FW, 0.22 5W) <0.010 0.020 <0.0050 Ethylene Glycol in mg/ L (any amount 77023 detected Tier One; 8,000 mg/L Tier Two and Three) <5.0 <5.0 <10 00552 Non -Polar Oil & Grease in mg/L (15) <2 5 0.83 <5.3 Estimated New Motor/Hydraulic Oil NCOIL Usage in gal/month 5-10 5-10 5-10 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): COD was missed inadvertently and will be completed on future samples. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting fal e nfbrmation,includingthepossibilityof iin4andimprisonmentforknowingviolations." Email Address igaied Authorized Individual Date Phone NIL mber