HomeMy WebLinkAboutSW6220603_Supplement-EZ Form_20220711SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
.PROJECT INFORMATION
1 Project Name Harnett Self Storage
2
Project Area (ac)
7.5 ----`
3
Coastal Wetland Area (ac)
0
4
Surface Water Area (ac)
0
5
Is this project High or Low Density?
High
6
Does this project use an off -site SCM?
Yes
COMPLIANCE
7
8
WITH 02H .1003(4)
Width of vegetated setbacks provided (feet) � 50
Will the vegetated setback remain vegetated? Yes
9
If BUA is proposed in the setback, does it meet NCAC 02H. 1 003(4)(c-d)? N/A
10
is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs: - -
11 Infiltration System
12
Bioretention Cell
13
Wet Pond
1
14
Stormwater Wetland
15
Permeable Pavement
16
Sand Filter
17
Rainwater Harvesting (RWH)
I 18
"
Green Roof
19
Level Spreader -Filter Strip (LS-FS)
20
Disconnected Impervious Surface (DIS)
21
Treatment Swale
22
Dry Pond
23
IStormFilter
24
Silva Ce11
25
Bayfiiter
26
Fiiterra
rORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title:
I Jarrod E. Hilliard, PE, CFM, Owner
28
Organization:
Hilliard Engineering, PLLC
29
Street address:
3417 Winterwind Circle
30
City, State, Zip_
Sanford, NC 27330
31
Phone number(s):
919-362-2834
32
1 Email:
_
jhilliard@hilliardengineering-com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
Signature oh5esigner
DRAINAGE AREAS
1
Is this a high density project?
Yes__ -�
2
_
It so, number of drainage areas/SCMs
1
3
Does this project have low density areas_?
No
4
If so, number of low density drainage areas
0
5 aversions?
Is all/part of this project subject to previous rule
—_
No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site
4y
wet pond
1,169,493 k
4
5
Type of SCM
JTotal drainage area (sq ft)
6
[Onsite drainage area (sq ft) EI
1,169,493
7
Offsite drainage area (sq ft)
8
9
Total BUA in project (sq ft)
New BUA on subdivided lots (subject to permitting)
(sq ft)
—
640933 sf
85658 sf
10
New BUA not on subdivided lots (subject to
1 permitting) (sf)
555275 sf
11
Offsite BUA (sq ft)
12
Breakdown of new BUA not on subdivided lots:
- Parking sq ft)
_
299520 sf�
- Sidewalk (sq ft)
16234 sf
- Roof (sq ft)
195961 sf
- Roadwa (sq ft)
- Future (sq ft)
43530 sf
- Other, please specify in the comment box
below (sq ft)
13
New infiltrating permeable pavement on
subdivided lots (sq ft)
14
New infiltrating permeable pavement not on
subdivided lots (sq ft)
15
Existing BUA that will remain (not subject to
permitting)
16
Existing BUA that is already permitted (sq ft)
296744 sf
117
Existing BUA that will be removed (sq ft
' 18
Percent BUA
55%
19
Design storm (inches)
1.0 in
e 20
Design volume of SCM (cu ft)
67707 cf
21
[Calculation method for design volume
simple
ADDITIONAL INFORMATION
— Please use this space to provide any additional information about the
22 drainage area(s):
i
OFF -SITE SCM
r
AINAGE AREA
rainage area number for this projectaster permit number SW6100804
rainage area number from the master permit 1
4 Lot or outparcel number
5 BUA allocated by Master Permit
INFORMATION ABOUT THE OFF -SITE SCM
6 Type of off -site SCM 1
7 jAvailable treatment capacity in the off -site SCM (cu ft)
8 Have deed restrictions limiting the BUA on the site been recorded?
9 Has an Engineer's Certification for the off_ -site SCM been submitted to DEQ
10 Are there any Notices of Violation for the off -site system?
11 Has the off -site SCM been maintained in accordance with its O&M Plan?
Residential Tract
779288 sf
Wet Pond
67707 cf
No
No
No
No
12 Will the collection system be maintained in its design state and kept clean? Yes
ADDITIONAL INFORMATION loom
f'113 i Please use this space to provide any additional information about the off -site SCM(s).
WET POND
1 Drainage area number 1
2 Minimum required treatm_ ent volume (cu ft) 64981 cf
GENERA! MDC FROM 02H 10S0
3
Is the SCI sized to treat the SW from all surfaces at build -out?
Yes
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
No
7
Are the inlets, outlets, and receiving stream protected from erosion
(10-year storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
N/A
14
Is there an O&M Agreement that complies with General MDC 01)?
Yes
151
Is there an O&M Plan that complies with General MDC (12)?
Yes
6
F17IWa,
Daes the SCM follow the device specific MDC?
Yes
the SCM designed by an NC licensed rofessional?
Yes
!Wt1 PUIND MDC: FROM 07H .1nS3
18
Sizing method used
SA/DA
19
Has a stage/storage table been provided in the calculations?
Yes
20
Elevation of the excavated main pool depth (bottom of sediment
removal) (fmsl)
_
427.00
21
Elevation of the main pool bottom (top of sediment removal) (fmsl)
428.00
22
Elevation of the bottom of the vegetated shelf (fmsl)
430.50
23
Elevation of the permanent pool (fmsi)
431,00
241
Elevation of the top of the vegetated shelf (fmsl)
431.50
251
Elevation of the temporary pool (fmsl)
432.00
261
Surface area of the main permanent pool (square feet)
63277
27
1 Volume of the main permanent pool (cubic feet)
163571 cf
28
1 Average depth of the main pool (feet)
3.30 ft
29
Average depth equation used
Equation 2
301
if using equation 3, main pool perimeter (feet)
31
If using equation 3, width of submerged veg. shelf (feet)
32
Volume of the forebay (cubic feet)
33939 cf
33
Is this 15-20% of the volume in the main pool?
Yes
34
Clean -out depth for forebay (inches)
12 in
35
Design volume of SCM (cu ft)
67707 of
36
Is the outlet an orifice or a weir?
Orifice
371
If orifice, orifice diameter (inches)
4 in
381
If weir, weir height (inches)
391
If weir, weir length (inches)
40
Drawdown time for the temporary pool (days)
4.07
41
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting?
Yes
42
Are berms or baffles provided to improve the flow path?
No
43
Depth of forebay at entrance (inches)
24 in
44
Depth of forebay at exit (inches)
24 in
45
Does water flow out of the forebay in a non -erosive manner?
Yes
46
Width of the vegetated shelf (feet)
loft
47
Slope of vegetated shelf (H:V)
10:1
48
Does the orifice drawdown from below the top surface of the
permanent pool?
Yes
49
Does the pond minimize impacts to the receiving channel from the 1-
yr, 24-hr storm?
Yes
50
Are fountains proposed? (If Y, please provide documentation that
MDC(9) is met.)
No
51
Is a trash rack or other device provided to protect the outlet system?
Yes
52
Are the dam and embankment planted in non -clumping turf grass?
No
53
Species of turf that will be used on the dam and embankment
54!
Has a planfing plan been provided for the vegetated shelf? I
No
I ZONAL INFORMATION
sE Please use this space to provide any additional information about the
Wet Pond 1 2:52 PM 6/11/2022