Loading...
HomeMy WebLinkAboutSW6220603_Design Calculations_20220711HARNETT SELF STORAGE Storm Water and Erosion & Sedimentation Control Calculations 0 Owner: Land 2020, Inc 350 Wagoner Drive Sanford, NC 27330 The certification shown below applies only to the items listed on this 'Table of Contents' Harnett Self Storage 2 Table of Contents Drainage Area Map 1 Page Runoff Coefficient 1 Page NOAA Rainfall Intensity 1 Page Mannings n 1 Page Temporary Diversion Ditches 4 Pages Permanent Swale 1 Page Temporary Skimmer Sediment Basin 1 Page Curb Inlet Capacity 1 Page Asphalt Inverted Swales 1 Page Storm Pipe Capacity 1 Page HILLIARD,. ENGINEERING Author: Jarrod E. Hilliard, PE, CFM PO Box 249 Sanford, NC 27331 (919) 352-2834 NC License No. P-0836 Date: 5/16/22 DRAINAGE AREA MAP HARNETT SELF STORAGE DRAINAGE AREA MAP SCALE: 1"=60' (11"X17" PAPER SIZE) -;a TIES 67°260711 — —W —EX 11°„ WM— _ NCSK 1141 144.59' _ _ - - — — — E DRIVE SFO - _ _ _ ALPINE OF_WAY (PAVED) � 00 - _ - — — — — — — _ 60' PUBLIC RIGHT- - SFO —W— _ o �00.35' s S 674-677__, -- --- E _ m �PLAT_BO9K_2010� PAGE __-- \ \\ A®4h au� ___—__ \ TIE — -- PIPE PIB" L III RCP 0 \ 1 N 8549' 1711 W ` RED t - _ -- ---- -- PIPE 13 30" Rol .o t \'' — _ II R \ ` \ SKIMM BASyv 01 214.64' — — — _ — — —_ — A: S . {�J — — PIPE 11 3p" CID. III RCP ®MIN. 0.65 R \0" V LENGT AT BASS 72' \ — __ -I� I __� -- e _—_— ♦ ■` IN. 050 \ WIDTH SPILLWAY: 8 — — — — --- GO NTCCOL CORN LI\ ✓ toot PE 07 FF PIPS 09 CL. III RCP ® MI N. I\\ WEIR V: 438 --- e° d « -L III RCP ®MIN. 1.15 ` \ I \ EX S S,5/8" SgC�D 1 Bo oM E eASI�: 434I — 2 � 90� sGo q^ CID. III RCP ®MIN. 0.75 R ` — I ce \ E C).73 ACRES CULVERT I R OTi — \ I \\ � 5' WIDE AM \ \ HEIR LE TH: 43' \ \ I�MMER IE: 4" \ TO DRIVE NO GRID �00000 Io I I I I \ C �� \\\ I \\AITERI ETIME3.5TDtYS \ amPte< CRES MW LEANOUT ELE 436.2 000000 0 °oa tr1s24A _------� !r �Z5/,94U5' dR' 0 0 mmae<9�11N.31NLE .� a _ - --i\\ 1\\�5 ICINL D N DEd 0A ID D NAD 8320J/1 000o0° ��odP,oe ° P�VIDEDo P�`t�o9 PIPE 2 1 O.O�O o rh 61 01 oa d0:5 I 2q" L III RCP ®M Wog e I �' 1 OVID I P O I \ \ \\ \ 1.13'ACRES Aso o_Uo I 1 2P 1 W \ I \ \ .� _ WIIEBSEWAIENI�ASI14 94PI E01 ♦ DA. 7.67 Acres / 000 -xoo o I / I ES ` ♦ I ERVIOUS AREA 1.40 AC. c=0.075 / ° / o o a, 1 MP DIVERSION 2 I 50 A .T IN 1 \ I 1 \` 'IC�PERVIOUS AREA 8.27 AC. c=0.9 ����```` o-o l -� 3.BIL Ac I ES �t COMPOSRE c= 0.75 ' r 1 P 0 AREA 8.84 I EDED IN. 2T I10= 7.87 in/hr i a 1 MI Ip I 1 l \ Q10= 45.27 cfs 4.„ ae . P c 9- POSRE c= NA o PRO sEwE _ _ ce 0= 7.� in�'hr o' I I ® I \ oz9 RE \ xlsnNc uryErvPes PR OSED LWETYPES / / o o v `s 10= 2 15 cfs i YERs nNo eRs / 0.93ACRES z ce` _0 10= 1. fps o I �� �® s \ ' SWALE DA w 1 s 0.19 AC+IMP. a- I \ I I fT1 I TOTAL IMPERVIOUS = 0.4� C \\� w 1 compositec=0.46,/ e ----- 1IIIIIRTi S 1 ----- : 0 6 ACRES E ACRE S I I I / 21NLETSN ED 0. 21NLET EDE � �' I 1 I I /aaA�sy L _ / hl L4 ROVIDED 3 ROVIDED I �— _ J IN 2INLET rEEDED i I 2P SFO �♦� 1 � I I i I� '�'iil� -0-0 3 1 J'' 141 ♦ 1 I I'I o IDN0 ♦__ 1 (D DO O 7� �j 1 1 \ I DA: 1 50 ACRL D.. 600 LF 'I I (1 0- , In R . Q C 1 1 % I I I SILT FENCE NFEDE DO -3 O 00 � —�� � I~ smf ���+ AV 1 1 1�� ` i 1 I I P D N 01� ON-S \ WsILrFENCEPR�vEDD)� 61aLF -, I FLT FENCASE ONCE SRDI`EN I I DA: .49 Ac \ SIN ISREM OW ➢ ` OUS AR 2.49 c=0 75 1\ P\\\ I 0- O O Cn 1 1 \ J 1 % I =_ ' cOM c= 075 . \I Q DO 1 I \ ` . z 110= Tin r � \ - I I I I / 1 1 vs QIO= .47 c \ 1 - —II CSF O J ? \ �O O P 00 r DA:0.67 CRES ♦ v \ I �C� 68LF E NEEDED: SILT FE 284 LF I 1 \ ` 0- - CE PROVIDE \ ` SILT FE I , \ 15" C. III RCP ' II ® MIN. 0.4 R \ I II 46 Fee, 1 INL ED _ 5' SE K ■■ ` \ 1 OVIDED_--- Ai — �, sA -- \ _ + iEM�PDNERSION 01A 0 - — — , �� A----- ------ -- \ US AREA: 1.07 AC. c=.075 • � ,� R = - -- - -� o w — _ no \ J 1 "T_ , Q10= 0.63ncfsr 5 ---- ---- _ wo� Wawa �— _ - ----------- - -----_ _ \ 3017 Sq. Wo �� r wm699.81' \ :� ����avow ��� ♦♦ IS BY 4'52" W \\ \� EXISTING 5/8" Maass SOLID IRON 1--------- `\ wuo nurocnu m mcr_crrcl RUNOFF COEFFICIENT 0 Table 8.03b Value of Runoff Coefficient (C) for Rational Formula Land Use C Land Use C Business: Lawns: Downtown areas 0.70-0.95 Sandy soil, flat, 2% 0.05-0.10 Neighborhood areas 0.50-0.70 Sandy soil, ave., 0.10-0.15 2-7% Residential: Sandy soil, steep, 0.15-0.20 Single-family areas 0.30-0.50 7% Multi units, detached 0.40-0.60 Heavy soil, flat, 2% 0.13-0.17 Multi units, Attached 0.60-0.75 Heavy soil, ave., 0.18-0.22 Suburban 0.25-0.40 2-7% Industrial: Heavy soil, steep, 0.25-0.35 Light areas 0.50-0.80 7% Heavy areas 0.60-0.90 Agricultural land: Parks, cemeteries 0.10-0.25 Bare packed soil Smooth 0.30-0.60 Playgrounds 0.20-0.35 Rough 0.20-0.50 Cultivated rows Railroad yard areas 0.20-0.40 Heavy soil no crop 0.30-0.60 Heavy soil with Unimproved areas 0.10-0.30 crop 0.20-0.50 Streets: Sandy soil no crop 0.20-0.40 Asphalt 0.70-0.95 Sandy soil with Concrete 0.80-0.95 crop 0.10-0.25 Brick 0.70-0.85 Pasture Heavy soil 0.15-0.45 Drives and walks 0.75-0.85 Sandy soil 0.05-0.25 Woodlands 0.05-0.25 Roofs 0.75-0.85 NOTE: The designer must use judgement to select the appropriate C value within the range for the appropriate land use. Generally, larger areas with permeable soils, flat slopes, and dense vegetation should have lowest C values. Smaller areas with slowly permeable soils, steep slopes, and sparse vegetation should be assigned highest C values. Source: American Society of Civil Engineers 8.03.6 Rev. 6/06 N OAA DATA Precipitation Frequency Data Server https://hdsc.nws.noaa.gov/hdsc/pfds/pfds_printpage.html?lat=3 5.3108&... NOAA Atlas 14, Volume 2, Version 3 Location name: Sanford, North Carolina, USA* t'X. Latitude: 35.3108°, Longitude:-79.0361°; Elevation: 441.55 ft** *source ESRI Maps %10 **source USGS POINT PRECIPITATION FREQUENCY ESTIMATES G.M. Bonnin, D. Martin, B. Lin, T. Parzybok, M.Yekta, and D. Riley NOAA, National Weather Service, Silver Spring, Maryland PF tabular I PFgraphical I Maps_&_aerials PF tabular PDS-based point precipitation frequency estimates with 90% confidence intervals (in inches/hour)1 Average recurrence interval (years) 1 2 5 10 25 50 100 200 500 1000 5-min 725 7 .57 6.8 .47 7..93), 12-8.72 6-9.67 (9.26-141.5) (9.71-12.2) 4.15 4.90 5.71 6.29 6.96 7.43 7.87 8.25 8.77 9.04 10-min (3.76-4.61) (4.45-5.45) (5.185.35) (5.69-6.98) (6.26-7.70) (7.03-8.69)11 (7.34-9.11) 1 (7.67-9.62) 1 (7.91-9.98) 3.46 4.77 4.82 5.37 5.88 6.27 6.63 6.94 7.37 7.56 15-min (3.143.84) (3.73-4.57) (4.375.35) (4.80-5.88) (5.29-6.51) (5.645.94)1 (5.92-7.32) 11 (6.17-7.66) 1 (6.44-8.07) 1 (6.62-8.35) 2.37 2.84 3.42 3.85 4.35 4.72 5.07 5.40 5.82 6.12 30-min (2.15-2.64) (2.57-3.16) (3.103.80) (3.48-4.26) (3.92-4.82) (4.245.22) (4.53-5.61) (4.805.97) (5.12-6.42) (5.36-6.76) 1.48 1.78 2.19 2.50 2.90 3.20 3.50 3.79 4.17 4.47 60-min (1.34-1.64) (1.62-1.98) (1.99-2.44) (2.27-2.78) (2.61-3.21) 1 (2.883.54) (3.12-3.86) (3.37-4.18) (3.68-4.61) (3.91-4.93) 0.868 7.05 7.37 7.57 7.78 7.99 2.79 2.40 2.68 2.90 2-hr (0.780-0.974) (0.946-1.18) 1 (1.18-1.47) 1 (1.36-1.69) 1 (1.58-1.99) 1 (1.76-2.22) (1.93-2.45) (2.11-2.68) (2.33-2.99) (2.50-3.24) 0.615 0.744 0.934 1.08 1.29 7.45 1.62 1.80 2.04 2.24 3-hr (0.553-0.691) (0.671-0.836) (0.840-1.05) (0.973-1.22) 1 (1.15-1.44) (1.29-1.63)1 (1.43-1.81)11 (1.57-2.01) 1 (1.76-2.28) 1 (1.91-2.50) 0.367 0.445 0.559 0.649 0.775 0.877 0.983 1.09 1.25 1.37 6-hr (0.334-0.408) (0.405-0.493) (0.507-0.619) (0.588-0.719) (0.696-0.856) (0.783-0.967) (0.869-1.08) (0.958-1.20) 1 (1.08-1.37) 1 (1.18-1.51) 0.216 0.267 0.330 0.385 0.463 0.527 0.594 0.666 0.768 0.857 12-hr (0.196-0.239) (0.237-0.289) (0.299-0.365) (0.348-0.426) (0.414-0.510) (0.468-0.580) (0.523-0.653) (0.580-0.731) (0.658-0.842) (0.720-0.933) 0.128 0.154 0.195 0.227 0.270 0.306 0.342 0.379 0.437 0.472 24-hr (0.118-0.138) (0.143-0.167) (0.180-0.210) (0.209-0.245) (0.249-0.292) (0.281-0.330) (0.313-0.369) (0.347-0.409) (0.392-0.465) (0.427-0.509) 0.074 0.089 0.112 0.130 0.154 0.174 0.194 0.215 0.243 0.266 2-day (0.069-0.080) (0.083-0.096) (0.104-0.121) (0.120-0.140) (0.143-0.166) (0.160-0.187) (0.178-0.209) (0.196-0.231) (0.221-0.263) (0.241-0.287) 0.052 0.063 0.079 0.091 0.108 0.121 0.135 0.150 0.169 0.185 3-day (0.049-0.056) (0.059-0.068) (0.073-0.084) (0.084-0.097) (0.100-0.116) (0.112-0.130) (0.124-0.145) (0.137-0.160) (0.154-0.182) (0.168-0.199) 0.042 0.050 0.062 0.077 0.085 0.095 0.106 0.117 0.132 0.744 4-day (0.039-0.044) (0.047-0.053) (0.058-0.066) (0.067-0.076) (0.078-0.090) (0.088-0.101) (0.097-0.113) (0.107-0.125) (0.121-0.141) (0.131-0.154) 0. 227 0.033 0.040 0.046 0.4 05 0.060 0.067 0.074 0.083 0.090 7-day (0.026-0.029) (0.031-0.035) (0.037-0.043) (0.043-0.049) (0.050-0.058) (0.056-0.065) (0.062-0.072) (0.068-0.079) (0.076-0.089) (0.082-0.097) 0.022 F 0. 226 0.032 0.036 0.041 0.046 0.057 0.055 0.061 0.066 10-day (0.021-0.023) (0.025-0.028) (0.030-0.034) (0.033-0.038) (0.039-0.044) (0.043-0.049) (0.047-0.054) (0.051-0.059) (0.057-0.065) (0.061-0.071) 0.015 0.017 0.027 0.023 0.027 0.029 0.032 0.035 0.039 0.042 20-day (0.014-0.016) (0.016-0.019) (0.019-0.022) (0.022-0.025) (0.025-0.028) (0.027-0.031) (0.030-0.034) (0.032-0.037) (0.036-0.041) (0.038-0.044) 0.012 0.014 0.017 0.019 0.027 0.023 0.025 0.027 0.029 0.037 F30-day 30-day (0.012-0.013) (0.014-0.015) (0.016-0.018) (0.018-0.020) (0.020-0.022) (0.022-0.025) (0.023-0.027) (0.025-0.029) (0.027-0.031) (0.029-0.033) 0.010 IF 0.012 IF 0.014 IF 0.015 0.017 0.018 IF0.020 IF0.021 IF0.023 IF0.024 45-day �(0.010-0.011) (0.011-0.013) (0.013-0.015) (0.014-0.016) (0.016-0.018) (0.017-0.020) (0.019-0.021) (0.020-0.022) (0.021-0.024) (0.022-0.026) 0.009 0.017 0.012 0.014 0.015 0.016 0.017 0.018 0.020 0.027 60-day (0.009-0.010) (0.010-0.011) (0.012-0.013) (0.013-0.014) (0.014-0.016) (0.015-0.017) (0.016-0.018) (0.017-0.019) (0.018-0.021) (0.019-0.022) Precipitation frequency (PF) estimates in this table are based on frequency analysis of partial duration series (PDS). Numbers in parenthesis are PF estimates at lower and upper bounds of the 90% confidence interval. The probability that precipitation frequency estimates (for a given duration and average recurrence interval) will be greater than the upper bound (or less than the lower bound) is 5%. Estimates at upper bounds are not checked against probable maximum precipitation (PMP) estimates and may be higherthan currently valid PMP values. Please refer to NOAA Atlas 14 document for more information. Back to Top PF graphical 1 of 4 3/18/2022, 12:41 PM MANNINGS n NCDEQ Stormwater Design Manual En vironmental Quality A=By+My2 P=B+2y(1 +M2)0.5 R = A / P Where: A = Cross -sectional area of flow (sq ft) B = Bottom width of the channel (ft) M = Side slope ratio (ft horizontal/ft vertical) P = Wetted perimeter, the distance along the cross- section against which water is flowing (ft) R = Hydraulic radius (ft) y = Depth of flow (ft) Figure 7: Schematic of Channel Cross -Section (Malcom 1989) • w • t------------ -------------: ti1 11 Note: M is often determined by channel side slope requirements, typically 3:1 (M=3) The Manning roughness coefficient is an experimentally determined value that is a function of the nature of the channel lining. Table 8: Rational Runoff Coefficients (adopted from Munson et al. 1990 and Chow et al. 1988) Asphalt 0.016 Concrete, finished 0.012 Concrete, unfinished 0.014 Grass 0.035 Gravel bottom with riprap sides 0.033 Weeds 0.040 B. Stormwater Calculations 12 Revised: 3-15-2017 TEMPORARY DIVERSION DITCHES OBJECTIVE: SOLUTIONS: RUNOFF CONDITIONS MAXIMUM Slope Condition SHEAR STRESS: RECOMMENDED LINING: TERMINOLOGY: Temporary Diversion Ditches HARNETT SELF STORAGE TEMPORARY DIVERSION 01A (ON -SITE) Verify Capacity of Temp Diversion Ditch Based Upon Q10 storm event. Check that swale will non-erosively pass the Q10 storm event Mannings Flow Equation c: 0.075 010 = 0.63 A (ac): 110 (cfs): 1.07 7.87 rfs d = n = B = Z Left = Z Right = Avg. S = 0.555 ft (min. flow depth for Q10 storm) (computed) ft (min. width) :1 (Berm Slope) :1 (Berm Slope) ft/ft (ovg. slope) A = P = R = Q10 Storm = V10 Storm = W = 0.62 2.48 0.25 0.63 1.01 2.22 FTA2 FT CFS FPS FT 0.058 0 2 2 0.010000 Berm Height: 0.945 ft Total Depth From Top of Berm to Bottom of Ditch: 1.50 ft Bottom Berm Width: 6.00 ft Top of Berm Width 1 2.00 ft T= Shear Stress Y= 62.4 PCF T= 0.346 PSF d= 0.56 FT S= 0.01 FT/FT Seed and Mulch With Contractor's Blend SAY: 7" DEPTH, 2.25' WIDE AT FLOW SURFACE Q = Peak Discharge,(CFS) V = Permissible Velocity, (FPS) d = Maximum Depth of Water, (FT) Vt= Trial Velocity, (FPS) n = Manning's "n" Coefficient V*R = Product of Velocity and Hydraulic Radius B = Bottom Width of Channel, (FT) Z = Side Slope of Channel (Z:1) CHANNEL LINING: With velocities less than 2 f/s use Seed and Mulching With velocites greater than 2 f/s use Temporary Ditch Liner : if T < 1 then use Coir Wattle against silt fence : if T > 1 then use other lining A = Cross -Sectional Area of Flow, (FT^2) P = Wetted Perimeter of the Flow, (FT) R = Hydraulic Radius, (FT) S = Slope of the Channel, (FT/FT) Q = Discharge,(CFS) V = Velocity, (FPS) W = Top Width of Water in Channel, (FT) Y = Specific Weight of Water (62.4 PCF) OBJECTIVE: SOLUTIONS: RUNOFF CONDITIONS MAXIMUM Slope Condition SHEAR STRESS: RECOMMENDED LINING: TERMINOLOGY: Temporary Diversion Ditches HARNETT SELF STORAGE TEMPORARY DIVERSION 01B (ON -SITE) Verify Capacity of Temp Diversion Ditch Based Upon Q10 storm event. Check that swale will non-erosively pass the Q10 storm event Mannings Flow Equation c: 0.075 010 = 1.47 A (ac): 110 (cfs): 2.49 7.87 rfs d = n = B = Z Left = Z Right = Avg. S = 0.765 ft (min. flow depth for Q10 storm) (computed) ft (min. width) :1 (Berm Slope) :1 (Berm Slope) ft/ft (ovg. slope) A = P = R = Q10 Storm = V10 Storm = W = 1.17 3.42 0.34 1.47 1.26 3.06 FTA2 FT CFS FPS FT 0.058 0 2 2 0.010000 Berm Height: 0.735 ft Total Depth From Top of Berm to Bottom of Ditch: 1.50 ft Bottom Berm Width: 6.00 ft Top of Berm Width 1 2.00 ft T= Shear Stress Y= 62.4 PCF T= 0.477 PSF d= 0.77 FT S= 0.01 FT/FT Seed and Mulch With Contractor's Blend SAY: 12" DEPTH, 3.06' WIDE AT FLOW SURFACE Q = Peak Discharge,(CFS) V = Permissible Velocity, (FPS) d = Maximum Depth of Water, (FT) Vt= Trial Velocity, (FPS) n = Manning's "n" Coefficient V*R = Product of Velocity and Hydraulic Radius B = Bottom Width of Channel, (FT) Z = Side Slope of Channel (Z:1) CHANNEL LINING: With velocities less than 2 f/s use Seed and Mulching With velocites greater than 2 f/s use Temporary Ditch Liner : if T < 1 then use Coir Wattle against silt fence : if T > 1 then use other lining A = Cross -Sectional Area of Flow, (FT^2) P = Wetted Perimeter of the Flow, (FT) R = Hydraulic Radius, (FT) S = Slope of the Channel, (FT/FT) Q = Discharge,(CFS) V = Velocity, (FPS) W = Top Width of Water in Channel, (FT) Y = Specific Weight of Water (62.4 PCF) OBJECTIVE: SOLUTIONS: RUNOFF CONDITIONS MAXIMUM Slope Condition SHEAR STRESS: RECOMMENDED LINING: TERMINOLOGY: Temporary Diversion Ditches HARNETT SELF STORAGE TEMPORARY DIVERSION 02 (ON -SITE) Verify Capacity of Temp Diversion Ditch Based Upon Q10 storm event. Check that swale will non-erosively pass the Q10 storm event Mannings Flow Equation c: 0.075 010= 2.15 A (ac): 110 (cfs): 3.64 7.87 rfs d = n = B = Z Left = Z Right = Avg. S = 0.882 ft (min. flow depth for Q10 storm) (computed) ft (min. width) :1 (Berm Slope) :1 (Berm Slope) ft/ft (ovg. slope) A = P = R = Q10 Storm = V10 Storm = W = 1.56 3.94 0.39 2.15 1.38 3.53 FTA2 FT CFS FPS FT 0.058 0 2 2 0.010000 Berm Height: 0.618 ft Total Depth From Top of Berm to Bottom of Ditch: 1.50 ft Bottom Berm Width: 6.00 ft Top of Berm Width 1 2.00 ft T= Shear Stress Y= 62.4 PCF T= 0.550 PSF d= 0.88 FT S= 0.01 FT/FT Seed and Mulch With Contractor's Blend SAY: 12" DEPTH, 3.53' WIDE AT FLOW SURFACE Q = Peak Discharge,(CFS) V = Permissible Velocity, (FPS) d = Maximum Depth of Water, (FT) Vt= Trial Velocity, (FPS) n = Manning's "n" Coefficient V*R = Product of Velocity and Hydraulic Radius B = Bottom Width of Channel, (FT) Z = Side Slope of Channel (Z:1) CHANNEL LINING: With velocities less than 2 f/s use Seed and Mulching With velocites greater than 2 f/s use Temporary Ditch Liner : if T < 1 then use Coir Wattle against silt fence : if T > 1 then use other lining A = Cross -Sectional Area of Flow, (FT^2) P = Wetted Perimeter of the Flow, (FT) R = Hydraulic Radius, (FT) S = Slope of the Channel, (FT/FT) Q = Discharge,(CFS) V = Velocity, (FPS) W = Top Width of Water in Channel, (FT) Y = Specific Weight of Water (62.4 PCF) OBJECTIVE: SOLUTIONS: RUNOFF CONDITIONS MAXIMUM Slope Condition SHEAR STRESS: RECOMMENDED LINING: TERMINOLOGY: Temporary Diversion Ditches HARNETT SELF STORAGE TEMPORARY DIVERSION 01 (OFF -SITE) Verify Capacity of Temp Diversion Ditch Based Upon Q10 storm event. Check that swale will non-erosively pass the Q10 storm event Mannings Flow Equation c: A (ac): 110 (cfs): 0.075 1.38 7.87 010 = 0.81 CIS d = n = B = Z Left = Z Right = Avg.S=l 0.261 ft (min. flow depth for Q10 storm) (computed) ft (min. width) :1 (Berm Slope) :1 (Existing terrain) t/ft (avg. slope) A = P = R = Q10 Storm = V10 Storm = W = 1.23 9.46 0.13 0.81 0.66 9.40 FTA2 FT CFS FPS FT 0.058 0 2 34 0.010000 Berm Height: 1.239 ft Total Depth From Top of Berm to Bottom of Ditch: 1.50 ft Bottom Berm Width: 6.00 ft Top of Berm Width 1 2.00 ft T= Shear Stress Y= 62.4 PCF T= 0.163 PSF d= 0.26 FT S= 0.01 FT/FT Seed and Mulch With Contractor's Blend SAY: 4" DEPTH, 10' NATURAL FLOW SPREAD AT TERMINUS Q= Peak Discharge, (CFS) V = Permissible Velocity, (FPS) d = Maximum Depth of Water, (FT) Vt = Trial Velocity, (FPS) n = Manning's "n" Coefficient V*R = Product of Velocity and Hydraulic Radius B = Bottom Width of Channel, (FT) Z = Side Slope of Channel (Z:1) CHANNEL LINING: With velocities less than 2 f/s use Seed and Mulching With velocites greaten than 2 f/s use Temporary Ditch Linen : if T < 1 then use Coir Wattle against silt fence : if T > 1 then use other lining A = Cross -Sectional Area of Flow, (FT^2) P = Wetted Perimeter of the Flow, (FT) R = Hydraulic Radius, (FT) S = Slope of the Channel, (FT/FT) Q= Discharge, (CFS) V= Velocity, (FPS) W = Top Width of Water in Channel, (FT) Y = Specific Weight of Water (62.4 PCF) PERMANENT SWALE OBJECTIVE: SOLUTIONS: RUNOFF CONDITIONS MAXIMUM Slope Condition SHEAR STRESS: RECOMMENDED LINING: TERMINOLOGY: Permanent Swale HARNETT SELF STORAGE SWALE A Verify Capacity of Permanent Swale Based Upon Q10 storm event. Check that swale will non-erosively pass the Q10 storm event Mannings Flow Equation c: 0.46 010 = 3.37 A (ac): 110 (cfs): 0.93 7.87 rfs d = n = B = Z Left = Z Right = Avg. S = 0.4284 ft (min. flow depth for Q10 storm) (computed) ft (min. width) :1 (Side Slope) :1 (Side Slope) ft/ft (avg. slope) A = P = R = Q10 Storm = V10 Storm = W = 3.67 17.16 0.21 3.37 0.92 17.14 FT^2 FT CFS FPS FT 0.058 0 20 20 0.010000 Berm Height. 1.072 ft Total Depth From Top of Berm to Bottom of Ditch: 1.50 ft Bottom Berm Width: 6.00 ft Top of Berm Width 2.00 ft T= Shear Stress Y= 62.4 PCF T= 0.267 PSF d= 0.43 FT S= 0.01 FT/FT Seed and Mulch With Contractor's Blend SAY: 6" DEPTH, 18' WIDE AT FLOW SURFACE Q = Peak Discharge, (CFS) V = Permissible Velocity, (FPS) d = Maximum Depth of Water, (FT) Vt = Trial Velocity, (FPS) n = Manning's "n" Coefficient V*R = Product of Velocity and Hydraulic Radius B = Bottom Width of Channel, (FT) Z = Side Slope of Channel (Z:1) CIiANNEL LINING: With velocities less than 2 f/s use Seed and Mulching With velocites greater than 2 f/s use Temporary Ditch Liner : if T < 1 then use Coir Wattle against silt fence : if T > 1 then use other lining A = Cross -Sectional Area of Flow, (FT^2) P = Wetted Perimeter of the Flow, (FT) R = Hydraulic Radius, (FT) S = Slope of the Channel, (FT/FT) Q = Discharge, (CFS) V = Velocity, (FPS) W = Top Width of Water in Channel, (FT) Y = Specific Weight of Water (62.4 PCF) TEMPORARY SEDIMENT SKIMMER BASINS HARNETT SELF STORAGE TEMPORARY SKIMMER BASIN 01 Okay 7.5 Disturbed Area (Acres) 45.27 Peak Flow from 10-year Storm (cfs) 13,500 Required Volume ft3 14,713 Required Surface Area ft2 85.8 Suggested Width ft 171.5 Suggested Length ft 86 Trial Top Width at Spillway Invert (ft) 172 Trial Top Length at Spillway Invert (ft) 3 Trial Side Slope Ratio Z:1 3.5 Trial Depth(ft) (2 to 3.5 feet above grade) 65 Bottom Width (ft) 151 Bottom Length(ft) 9,815 Bottom Area ft2 42,805 Actual Volume ft3 Okay 14,792 Actual Surface Area ft2 Okay 43 Trial Weir Length (ft) 0.5 Trial Depth of Flow (ft) 45.6 Spillway Capacity (cfs) Okay 2.12 Spillway Velocity (ft/s) (Use Enka, Geotextile Fabric or Equiv.) 4 Skimmer Size (inches) 0.333 Head on Skimmer (ft) 3 Orifice Size (inches) (1/4 inch increments) 3.57 Dewatering Time (days) (dewatering Time should be 2-5 days) 5 Embankment Height for Spillway Minimum 6" Above Storage Level and 1' Freeboard (ft from bottom) 1.75 Sediment Cleanout Elevation (ft from bottom) Skimmer Size (Inches) 1.5 2 2.5 3 4 5 6 8 CURB INLET CAPACITY Curb Inlet Capacity HARNETT SELF STORAGE 25-Year Design Storm OBJECTIVE: Size Grate Inlets to intercept stormwater runoff Assume 50% Clogged For Any Sump Condition BASE DESIGN ON USE OF: Type of Grate Proposed: Grate Inlet RUNOFF: c: 0.95 I: 8.74 inches per hour *A: 0.50 acres 010: 4.15 cfs Orifice Equation: Total Post-Dev(Q10)= 4.15 cfs Post-Dev. Q(10)= 4.15 cfs (per inlet) CD= 0.67 g= 32.2 ft/sz d= 0.323 ft ( driving head for max spread) = 3.876 inches Clear Opening Area Required= 195.2 sq. in Clear Opening Area Required Sump Condition (50% Blockage)= 292.87 sq. in SOLUTION: Select Curb Inlet open area with approx.: 196.0 sq. in USE: Number of Curb Inlets: Length: Brand: Model: Open Area Obtained (sq. in.) 1 39.75" East Jordan Iron Works V4870 216.3 * Target as max drainage area to any I inlet ASPHALT INVERTED SWALES OBJECTIVE: SOLUTIONS: RUNOFF CONDITIONS MAXIMUM Slope Condition SHEAR STRESS: ASPHALT INVERTED SWALES HARNETT SELF STORAGE BASED UPON MAXIMUM ALLOWABLE DRAINAGE AREA TO ANY SINGLE INLET 5 % SIDE SLOPE Verify Capacity of Asphalt Inverted Swale Based Upon Q25 storm event. Check that swale will pass the Q25 storm event without the flow depth along the swale rising more than an average of 0.25' (Approx. 3") Mannings Flow Equation MAX c: A (ac): 125 (in/hr): 110 (cfs): 0.95 0.690 8.74 7.87 (Allowable) 010 = 5.73 cfs d = n = 8 = Z Left = Z Right = Avg. S = 0.323 ft (allowable flow depth for Q25 storm, one lane open; 1" B FIFE) (Table 8, Design Manual) ft (min. width) :1 (5% side slopes) :1 (5% side slopes) t/ft (avg. slope) A = P = R = Q25 Storm = V25 Storm = W = 2.08 12.92 0.16 5.73 2.76 12.90 FTA2 FT CFS FPS FT 0.016 0 20 20 0.010000 T= Shear Stress T= 0.201 PSF Y= d= S= 62.4 0.32 0.01 PCF FT FT/FT M AUJUJ I IIVI, IVIAAIIVIUIVI ALLUVVAtSLt UKAIIVAUt AKtA, I Fit DRAINAGE AREA TO ANY SINGLE INLET SHOULD BE NO MORE THAN 0.690 ACRES TERMINOLOGY: USING 25%SAFETY FACTOR, MAX DRAINAGE AREA TO ANY SINGLE INLET = 0.52 ACRES Q = Peak Discharge, (CFS) A = Cross -Sectional Area of Flow,(FT^2) V = Permissible Velocity, (FPS) P = Wetted Perimeter of the Flow, (FT) d = Maximum Depth of Water, (FT) R = Hydraulic Radius, (FT) Vt = Trial Velocity, (FPS) S = Slope of the Channel, (FT/FT) n = Manning's "n" Coefficient Q= Discharge, (CFS) V*R = Product of Velocity and Hydraulic Radius V = Velocity, (FPS) B = Bottom Width of Channel, (FT) W = Top Width of Water in Channel, (FT) Z = Side Slope of Channel (Z:1) Y = Specific Weight of Water (62.4 PCF) CHANNEL LINING: With velocities less than 2 f/s use Seed and Mulching With velocites greaten than 2 f/s use Temporary Ditch Linen : if T < 1 then use Coir Wattle against silt fence : if T > 1 then use other lining STORM PIPE CAPACITY PIPE ID PIPE 01 PIPE 02 PIPE 03 PIPE 04 PIPE 05 PIPE 06 PIPE 07 PIPE 08 PIPE 09 PIPE 10 PIPE 11 PIPE 12 PIPE 13 PIPE 14 PIPE 15 PIPE 16 PIPE 17 PIPE 18 PIPE 19 PIPE 20 PIPE 21 PIPE 22 PIPE 23 DRIVEWAY CULVERT HARNETT SELF -STORAGE D Pipe Dia. (Inches) S Pipe Slope Velocity (fps) Discharge (gpm) Discharge (cfs) NUMBER OF PIPES TOTAL CAPACITY (cfs) 15 0.500% 3.72 fps 2,050 4.57 1 4.57 24 0.450% 4.83 fps 6,811 15.18 1 15.18 15 0.400% 3.33 fps 1,834 4.09 1 4.09 15 0.400% 3.33 fps 1,834 4.09 1 4.09 15 0.400% 3.33 fps 1,834 4.09 1 4.09 24 0.700% 6.02 fps 8,495 18.93 1 18.93 24 0.750% 6.24 fps 8,793 19.59 1 19.59 15 0.400% 3.33 fps 1,834 4.09 1 4.09 24 1.150% 7.72 fps 10,888 24.26 1 24.26 15 0.400% 3.33 fps 1,834 4.09 1 4.09 30 0.500% 5.91 fps 13,017 29.00 1 29.00 15 0.400% 3.33 fps 1,834 4.09 1 4.09 30 0.650% 6.74 fps 14,841 33.07 1 33.07 15 0.400% 3.33 fps 1,834 4.09 1 4.09 15 1.000% 5.26 fps 2,899 6.46 1 6.46 30 1.000% 8.36 fps 18,409 41.02 1 41.02 15 0.400% 3.33 fps 1,834 4.09 1 4.09 15 0.400% 3.33 fps 1,834 4.09 1 4.09 18 0.500% 4.20 fps 3,334 7.43 1 7.43 36 0.650% 7.61 fps 24,134 53.77 1 53.77 36 0.650% 7.61 fps 24,134 53.77 1 53.77 36 0.650% 7.61 fps 24,134 53.77 1 53.77 15 0.400% 3.33 fps 1,834 4.09 1 4.09 18 0.500% 4.20 fps 3,334 7.43 1 7.43 C I (in/hr) A (ac) Q (cfs) Capacity o.k? 0.46 8.74 1.13 4.54305 Yes 0.95 8.74 1.8 14.9454 Yes 0.95 8.74 0.49 4.06847 Yes 0.95 8.74 0.45 3.73635 Yes 0.95 8.74 0.3 2.4909 Yes 0.95 8.74 2.22 18.4327 Yes 0.95 8.74 2.34 19.429 Yes 0.95 8.74 0.34 2.82302 Yes 0.95 8.74 2.92 24.2448 Yes 0.95 8.74 0.32 2.65696 Yes 0.95 8.74 3.47 28.8114 Yes 0.95 8.74 0.29 2.40787 Yes 0.95 8.74 3.97 32.9629 Yes 0.95 8.74 0.45 3.73635 Yes 0.95 8.74 0.74 6.14422 Yes 0.95 8.74 4.93 40.9338 Yes 0.95 8.74 0.29 2.40787 Yes 0.95 8.74 0.46 3.81938 Yes 0.95 8.74 0.88 7.30664 Yes 0.95 8.74 6.37 52.8901 Yes 0.95 8.74 6.37 52.8901 Yes 0.95 8.74 6.37 52.8901 Yes 0.95 8.74 0.3 2.4909 Yes 0.95 8.74 0.73 6.06119 Yes