Loading...
HomeMy WebLinkAbout20191302 Ver 1_NCDOT DIV 5 non-reporting NWP_2021_20220712County State Road Road Name Location (Distance and direction from closest SR) LAT LONG Existing Structure Proposed Structure Problem Proposal Nearest Stream Name DWQ Classificat ion Bank Stabilization (Linear Feet) Slope Protection w/jurisdictional impacts Stream Channel (Linear Feet)- Permanent Wetland (Acres) Stream Channel (Linear Feet)- Temporary T & E Species Present? Yes or No Historic Concerns Most Recent Site Visit Permit Requirements and Comments Additional Comments Durham NC 751 Academy Rd 170ft S of US 15-501 BUS (off ramp from US 15/501 BUS to NC 751) 35.97157 -78.94339 72" CMP at 128'- 4" 84" CASPP at 13 2ft pipe failure pipe replacement UT to Sandy Creek WS-V, NSW 40LF: 20LF inlet/20LF outlet N/A 3ft-8in longer 22ft of countersunk rip rap at outlet N/A 10LF No No 4/21/2021 Jordan Lake Watershed minor impacts DEEMED ALLOWABLE without authorization Contract- complete Franklin SR 1132 Fleming Rd 1.35mi N of SR 1100 36.04256 -78.47693 54" CMP at 60ft 14' - 8" x 9' - 8" CASPPA at 54ft pipe failure pipe replacement Brandy Creek B; NSW 40LF: 20LF inlet/20LF outlet N/A 20ft of countersunk rip rap at outlet N/A 10LF No No 5/24/2021 Tar-Pamlico River Basin: minor impacts DEEMED ALLOWABLE without authorization in-house complete Warren SR 1107 Ridgeway Warrenton Road 1.0mi E of SR 1143 36.41926 -78.20789 48" RCPat 55ft 81" x 59" CMP at 60ft pipe failure pipe replacement Owens Creek C; NSW 20LF: 15LF inlet/5LF outlet concurrent N/A 5ft longer pipe N/A 10LF No No 6/14/2021 Tar-Pamlico River Basin: minor impacts DEEMED ALLOWABLE without authorization in-house complete Warren SR 1371 Salmon Landing Road 170ft E of NC 903 36.48611 -77.94938 30" CMP at 50ft 30" CMP at 50ft pipe failure pipe replacement UT to Roanoke (Lake Gaston) WS-V, B N/A 40LF: 20LF inlet/outlet 0 N/A 10LF No No 6/14/2021 Roanoke River Basin No Buffer Impacts in-house complete Warren SR 1471 Whispering Pines Rd 0.14mi SR of SR 1477 36.52931 -78.05099 36" RCP at 60ft 73" x55" CMP at 60ft pipe failure pipe replacement UT to Roanoke (Lake Gaston) WS-V, B 10LF: 5LF inlet/outlet concurrent N/A 0 N/A 10LF No No 6/14/2021 Roanoke River Basin No Buffer Impacts in-house complete Wake SR 2224 Mitchell Mill Rd 1.67mi SW of NC 96 35.9009 -78.4064 128"x83" CMPA at 50ft 155" x 90" CASPPA at 50ft pipe failure pipe replacement UT to Fowlers Mill Creek WS-II; HQW; NSW 40LF: 20LF inlet/20LF outlet N/A 0 0.0046 10LF No No 8/16/2021 Neuse River Basin: minor impacts DEEMED ALLOWABLE without authorization 2018 storm damage Contract - complete