Loading...
HomeMy WebLinkAboutSW4220601_Supplement-EZ Form_20220712SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name _____ Havenbrooke Subdivision 2 Project Area (ac) 74.97 3 Coastal Wetland Area (ac) 0 _ 4 Surface Water Area (acL 0.78 5 Is this project High or Low Density? Low 6 1 Does this project use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided (feet) _. _... ---- ... ....... � 30 w _8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003(4)(c-d)? NIA 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SOMA: 11 Infiltration System 12 Bioretention Cell 13 _ Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter y 17 Rainwater Harvesting (RW H) 1Green Roof _ 19 Level Spreader -Filter Strip 20 Disconnected Impervious Surface (DIS) _ 21 Treatment Swale _ 6 22 Dry Pond _ 23 StormFilter 24 Silva Cell 25 Bayfilter 26 IFIlterra FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: James L. Walters, P.E. 28 Organization: Latham -Walters Engineering, Inc. 29 Street address: 16507-A_Northcross Drive 30 City, State, Zip: Huntersville, NC 28078 31 Phone number(s): 704-807-4134 32 Email: jim@lwengineer.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. E,lor011$1#10"" ® SEAL � 18564 - S - m '��NPnitrrrrrr k '�" //G Igo zZ Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so, number of drainage areas/SCMs 3 Does this project have low density areas? Yes 4 If so, number of low density drainage areas 6 5 Is all/part of this project subject to previous rule versions? No CLICK TO LOAD FORM LOW DENSITY DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 021-11.1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per.1003(2)(c)? No 4 Side slopes of the vegetated conveyances (H:V) 3 sf 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 6 6 Are curb outlet swales proposed? Yes 7 Maximum longitudinal slope of curb outlet swale(s) (%) 5 8 Bottom width of curb outlet swale(s) (feet) 5 ft 9 Maximum side slope of curb outlet swale(s) (H:V) :1 10 Minimum length of curb outlet swale(s) (feet) 100 ft 11 Are treatment swales used instead of curb outlet swales? No 12 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule .1003 proposed? No ADDITIONAL INFORMATION 15 JlPlease use this space to provide any additional information about this low density project: A combination of curb outlets and treatment swales are proposed along with vegetated conveyance ditches. TREATMENT SWALE 1 Drainage area number Desi n flow rate of SCM cfs 1 2 3 2 3.61 cfs 1.65 cfs 1.31 cfs GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes Yes 5 What are the side slopes of the SCM (H:V)? 3:1 3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No No No 7 Are the inlets, outlets, and receiving stream protected from erosion 10- ear storm)? Yes Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? No No No 9 What is the method for dewatering the SCM for maintenance? Other Other Other 10 If applicable, will the SCM be cleaned out after construction? Yes Yes Yes 11 Does the maintenance access comply with General MDC (8)? Yes Yes Yes 12 Does the drainage easement comply with General MDC (9)? Yes Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC 10 ? Is there an O&M Agreement that complies with General MDC (11)? Yes Yes Yes 14 Yes Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes Yes 17 Was the SCM designed by an NC licensedprofessional? Yes Yes Yes TREATMENT SWALE MDC FROM 02H .1061 18 SHWT elevation (fmsl) <832 <832 <832 19 Bottom of the treatment swale (fmsl) 838.00 852.00 852.00 20 Depth of treatment swale (feet) 2' 2' 2' 21 Is the swale trapezoidal in shape? Yes Yes Yes 22 Width of bottom of swale (feet) 2 ft 2 ft 2 ft 23 Side slopes of treatment swale (H:V) 3:1 3:1 3:1 24 Length of swale (feet) 150 ft 140 ft 130 ft 25 Flow depth during the 0.75 inch/hour storm (inches) 3 in 3 in 2 in 26 Flow velocity during the 0.75 inch/hour storm (feet per second) 4 fps 3 fps 3 fps 27 Hydraulic retention time for swale (minutes) 4 min 4 min 4 min 28 Species of grass that will be used Tall Fescue Tall Fescue Tall Fescue 29 Will the grass be maintained at an average height of 6 inches? Yes Yes Yes 30 Will the grass not be cut lower than 4 inches? Yes No No 31 Velocity during the 10-year storm (feet per second) 6 ft/s 6 ft/s 5 ft/s 32 Is the swale designed to non -erosive) ass the 10- ear storm? Yes Yes Yes ADDITIONAL INFORMATION 33 Please use this space to provide any additional information about the treatment swale(s): TrSwale 4 1:57 PM 6/16/2022 TREATMENT SWALE 1 Drainage area number Desi n flow rate of SCM cfs 4 5 6 2 1.84 cfs 1.31 cfs .42 cfs GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes Yes 5 What are the side slopes of the SCM (H:V)? 3:1 3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No Yes Yes 7 Are the inlets, outlets, and receiving stream protected from erosion 10- ear storm)? Yes Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? No No No 9 What is the method for dewatering the SCM for maintenance? Other Other Other 10 If applicable, will the SCM be cleaned out after construction? Yes Yes Yes 11 Does the maintenance access comply with General MDC (8)? Yes Yes Yes 12 Does the drainage easement comply with General MDC (9)? Yes Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC 10 ? Is there an O&M Agreement that complies with General MDC (11)? Yes Yes Yes 14 Yes Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes Yes 17 Was the SCM designed by an NC licensedprofessional? Yes Yes Yes TREATMENT SWALE MDC FROM 02H .1061 18 SHWT elevation (fmsl) <828 <836 <832 19 Bottom of the treatment swale (fmsl) 868.00 858.00 874.00 20 Depth of treatment swale (feet) 2' 2' 2' 21 Is the swale trapezoidal in shape? Yes Yes Yes 22 Width of bottom of swale (feet) 2 ft 2 ft 2 ft 23 Side slopes of treatment swale (H:V) 3:1 3:1 3:1 24 Length of swale (feet) 167 ft 103 ft 125 ft 25 Flow depth during the 0.75 inch/hour storm (inches) 3 in 3 in 2 in 26 Flow velocity during the 0.75 inch/hour storm (feet per second) 3 fps 2 fps 1 fps 27 Hydraulic retention time for swale (minutes) 4 min 4 min 4 min 28 Species of grass that will be used Tall Fescue Tall Fescue Tall Fescue 29 Will the grass be maintained at an average height of 6 inches? Yes Yes Yes 30 Will the grass not be cut lower than 4 inches? No No No 31 Velocity during the 10-year storm (feet per second) 6 ft/s 3 ft/s 1 ft/s 32 Is the swale designed to non -erosive) ass the 10- ear storm? Yes Yes Yes ADDITIONAL INFORMATION 33 Please use this space to provide any additional information about the treatment swale(s): TrSwale 5 1:57 PM 6/16/2022