Loading...
HomeMy WebLinkAboutMecklenburg_Well Abandonment_20220708 WELL ABANDONMENT RECORD For Internal Use ONLY: 1.Well Contractor Information: WELL ABANDONMENT DETAILS Billy Payne 7a.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same Well Contractor Name(or well owner personally abandoning well on his/her property) well construction/depth,only 1 GW-30 is needed. Indicate TOTAL NUMBER of 4532-B wells abandoned: NC Well Contractor Certification Number 7b.Approximate volume of water remaining in well(s): 1'1 (gal.) Excel-SRP Environmental FOR WATER SUPPLY WELLS ONLY: Company Name Chlorination-Ca(OCI)2 2.Well Construction Permit#: 70002992 7c.Type of disinfectant used: List all applicable well construction permits(i.e.UIC,County,State,Variance,etc.)if known 3-0 u n ces 7d.Amount of disinfectant used: 3.Well use(check well use): Water Supply Well: 7e.Seating materials used(check all that apply): ❑Agricultural ❑Municipal/Public a Neat Cement Grout a Bentonite Chips or Pellets ❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ❑ Sand Cement Grout ❑ Dry Clay ❑lndustrial/Commercial ❑Residential Water Supply(shared) a Concrete Grout ❑ Drill Cuttings ❑Irri ation ❑ Specialty Grout ❑Gravel Non-Water Supply Well: ❑ Bentonite Slurry ❑Other(explain under 7g) eMonitoring ❑Recovery Injection Well: 7f.For each material selected above,provide amount of materials used: ❑Aquifer Recharge ❑GroundwaterRemediation Benton ite-20-Ibs Neat Cement-5-Ibs ❑Aquifer Storage and Recovery ❑Salinity Barrier Concrete-5-Ibs El Aquifer Test ❑Stormwater Drainage ❑Experimental Technology ❑Subsidence Control 7g.Provide a brief description of the abandonment procedure: ❑Geothermal(Closed Loop) ❑Tracer ❑Geothermal(Heating/CoolingReturn) ❑Other(explain under 7 Disinfected well, sealed well with Bentonite & neat cement, capped well wit rete to the lid. 4.Date well(s)abandoned: 6-17-2022 /JZ 5a.Well location: l Q,OP/,''�`` Sams Mart 37 C7 Facility/Owner Name Facility 1D#(ifapplicable) 8.('ert' ation: trrt4 3' 2700 N Tryon St Charlotte NC '10.11t W22 Physical Address,City,and Zip S' of Certifi W I Con ctor or Well Owner Date Mecklenburg 08302202 By signing this form, I hereby certify that the well(s) was (were)abandoned in Count, Parcel Identification No.(PIN) accordance with ISA NCAC 02C.0100 or 2C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. Sb.Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field one lavlong is sufficient) 9.Site diagram or additional well details: 35014' 56.21" N -80048' 54.28" W You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. CONSTRUCTION DETAILS OF WELL(S)BEING ABANDONED SUBMITTAL INSTRUCTIONS Attach well construction record(s)ifavailable.For multiple injection or non-water supply wells ONLY with the same constructionlabandonment,you can submit one form. 10a. For All Wells: Submit this form within 30 days of completion of well 6a.Well ID#• MW-1 abandonment to the following: Division of Water Resources,Information Processing Unit, 6b.Total well depth: 18.00 (ft) 1617 Mail Service Center,Raleigh,NC 27699-1617 10b.For Iniection Wetis: In addition to sending the form to the address in 10a 6c.Borehole diameter- 4.25 (in) above, also submit one copy of this form within 30 days of completion of well abandonment to the following: 6d.Water level below ground surface: 11 (ft.) Division of Water Resources,Underground Injection Control Program, 1636 Mail Service Center,Raleigh,NC 27699-1636 6e.Outer casing length(if known): 0-8 (ft,) 10c.For Water Supply&Iniection Wells: In addition to sending the form to the address(es)above,also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the county where 6E Inner casing/tubing length(if known): (ft,) abandoned. 6g.Screen length(if known): 8-18 (ft.) Form GW-30 North Carolina Department of Environmental Quality-Division of Water Resources Revised 2-22-2016