Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW6140804_APPROVED PLANS_20140825
STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT (� APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATEL7 r/r5 YYYYMMDD u c w 0 0 N N Q a a `o z I T v Y T a ° r a 0 t N U C N N O V O N N Q a C O C O I d E Y 0 0 n 0 a 0 0 0 0 N O r 0 d a r n 's J a v E 0 0 Y n it N Q � c � o T v � u c n � E � v o r o J `a Y E w v v o s n o C N _O y Y � K J Z ti v 0 a o °1 n N I r _~ L v 3 7 O c U n J o � v 0 � a J U I ° J v Q a Y n Y .. _o T E 0 n ° c � n v N '- D N ti U N v u ° A ° E � E N n ° J (2) 4" DIA. PVC UNDERDRAIN PIPES ELEV.=236.90 SODDED SIDE SLOPES AND BOTTOM CLASS "C" GEOTEXTILE FABRIC ALONG SIDE OF BIORETENTION ALONG COMPACTED SUBGRADE NATIVE SOIL, NO BIORETENTION SOIL MIXTURE (VARIES) BIORETENTION SOIL I I MIXTURE PER SPECIFICATION II CLEAN OUT, TYP. SECTION A' -A': UNDERDRAIN NOT TO SCALE ITEM PERCENT BY WEIGHT MATERIAL SAND 85-881 CONSTRUCTION SAND FINES 8-12% SILT AND CLAY ORGANIC MATTER 3-5% PEAT MOSS SODDED SIDE SLOPES AND BOTTOM 4" SCHEDULE 40 PVC, SDR-35, OR SMOOTH WALL CORRUGATED PLASTIC PIPE SLOPED AT 0.10% CAPPED CLEAN OUT, TYP. TOP 6" ABOVE GROUND ELEV. INV. = 239.90 I 1 BIORETENTION SOIL MIXTURE PER SPECIFICATION I . - ._Zdn_ CS-10 (SEE DETAIL THIS SHEET) L STANDARD PVC WYE FITTINGS SOLVENT WELDED CONNECTION SECTION B'-B': UNDERDRAIN NOT TO SCALE 11310-RETENTION CELL #1 THICK )NCRETE \LLS ;ATE RCP OUTLET 00.507 INV=236.33 SECTION A -A (2) 4" DIA. PVC UNDERDRAIN PIPES ELEV.=236.90 W�r -adi CLASS "C" GEOTEXTILE FABRIC ALONG SIDE OF BIORETENTION ALONG COMPACTED SUBGRADE CLASS "C" GEOTEXTILE FABRIC AROUND WASHED STONE #57 STONE (WASHED) 4" SCHEDULE 40 PVC, SDR-35, OR SMOOTH WALL CORRUGATED PLASTIC PIPE SLOPED AT 0.10% MIN. WITH 3/8" PERFERATIONS 6" ON CENTER (4 HOLES PER ROW) NOTES: PONDING DEPTH: 12" UNDERDRAIN TO BE 3/8" PERE 0 6" O.C., 4 HOLES PER ROW, SLOPED AT 0.10% MINIMUM; GRAVEL NOT NECESSARY UNDER PIPES. UNDERDRAIN PIPES AND CLEANOUTS SHOULD BE LOCATED IN THE QUANTITY AND ELEVATION FOUND ON THE GRADING AND DRAINAGE PLAN. SANDY LOAM/LOAMY SAND; FINES SHOULD BE LIMITED TO TWENTY PERCENT OR LESS PASSING THROUGH A #200 SIEVE. MINIMUM INFILTRATION RATE = 2"/HR N SOIL, NO COMPACTION 100—YR WSEL=240.52 2 —YR WSEL=240.46 TOP OF RISER in_va wcr•I —o)dn An ELEV.=240.40 15" RCP OUTLET 0 0.50% INV=236.33 A 1310-RETENTION CELL #1 CONTROL STRUCTURE CS-10 NOT TO SCALE 15" RCP TE \_(2) 4" DIA. PVC UNDERDRAIN PIPES ELEV.=236.90 SECTION B-B EXTEND TO EXISTING STORM STRUCTURE Total Bioretention Storage Volume (Water Quality): GRAPHIC SCALE IN FEET 0 10 20 40 Elevation Contour Area Incremental Volume Accumulated Volume Stage, Z sq ft cu ft cu It It 239.40 2,191 0 0 0.00 240.40 2,828 2,510 2,510 1.00 240.90 3,168 1,499 4,009 1.50 Bioretention Soil Mixture (BSM): shall be placed and graded using low ground —contact pressure equipment or by excavators and/or backhoes operating on the ground adjacent to the bioretention facility. No heavy equipment shall be used within the perimeter of the bioretention facility before, during, or after the placement of the BSM. The BSM shall be placed in horizontal layers not to exceed 12 inches for the entire area of the bioretention facility. The BSM shall be compacted by saturating the entire area of the bioretention facility after each lift of BSM is placed until water flows from the underdrain. Water for saturation shall be applied by spraying or sprinkling. An appropriate sediment control device shall be used to treat any sediment —laden water discharged from the underdrain. If the BSM becomes contaminated during the construction of the facility, the contaminated material shall be removed and replaced with uncontaminated material at no additional cost to the Owner. Final grading of the BSM shall be performed after a 24—hour settling period. Final elevations shall be within 2 inches of elevations shown on the Contract Plans. The Bioretention Soil Mixture (BSM) shall be a uniform mix, free of stones, stumps, roots or other similar objects larger than two inches excluding mulch. No other materials or substances shall be mixed or dumped within the bioretention area that may be harmful to plant growth, or prove a hindrance to the planting or maintenance operations. Prior to placing the underdrain and the BSM, the bottom of the excavation shall be roto—tilled to D minimum depth of 6 inches to alleviate any compaction of the facility bottom. Any substitute method for roto—tilling must be cpproved by the Engineer prior to use. Any ponded water shall be removed from the bottom of the facility and the soil shall be friable before roto—tilling. Grass sod shall be used in bioretention area. Grassed sod must not be grown in soil with an impermeable (clay) layer. BSM must have a P—index of 10 to 30. BIORETENTION MAINTENANCE NOTES, 1. BIORETENTION AREA SHOULD DRAIN DOWN IN 12 HOURS AFTER A t" STORM. IF WATER PONDS LONGER, MAINTENANCE IS REQUIRED. 2. REMOVE SEDIMENT FROM UPSTREAM DRAINAGE AREAS SO BIORETENTION DOES NOT CLOG. 3.REMOVE TRASH REGULARLY. Approved Stormwater Permit Documents Construction in accordance with these documents is required by the stormwater permit. North Carolina rules require that the stormwater system designer Inspect during construction; certify conformity with the plans and specs; and certify compliance with the stormwater rules. (15A NCAC 2H .1008 Ill) Permitk574/619oB04 Oate 8.22 /Nf by %22z. jP..,tLf NC Division of Water Quality Sheet # G //. oG Revision Date.B/ . KHA PROJECT ■ �anuuun 011737212 ��� ��, SHEET NUMBER lmley)))Horn FT. BRAGG, NORTH n 5 REVISED PER 12" WATERMAIN LOCATION 8/18/14 DAW DATE 5/14/ CARO L I NA SCALE AS SHOWN - , = STORMWATER DETAILS °o 02014 KIMLEY-HORN AND ASSOCIATES, INC. C 11 00 2 REVISED PER DPW COMMENTS - LEE WARD (6/12/14) 6/18/14 BJC 333 FAYETTEVILLE STREET, SUITE 600, RALEIGH, NC 27601 DESIGNED BY PAB Q D PREPARED FOR 'ro'Fiy�IN�FQ• O PHONE: 919-835-1494 FAX: 919-653-5847 DRAWN BY DAW '%�� u 1 REVISED DRIVE—THRU WIDTHS PER OWNER REQUEST 6/4/14 DAW /;/// A ��WWW.KIMLEY-HORN.COM FIRST CITIZENS BANK ,114, o No. REVISIONS DATE BY NC LICENSE #F-0102 CHECKED BY PAB CONTACTS OWNER, FIRST CITIZENS BANK 100 EAST TRYON ROAD RALEIGH, NC 27603 PHONE: (919) 716-8497 FAX: 919-716-8840 ATTN: ROB TESSAR CIVIL ENGINEER KIMLEY-HORN AND ASSOCIATES, INC. 333 FAYETTEVILLE STREET SUITE 600 RALEIGH, NC 27601 PHONE: (919) 677-2164 ATTN: PETER BISHOP, P.E. ARCHITECT- WINSTEAD WILKINSON ARCHITECTS 600 WADE AVENUE RALEIGH, NC 27605 PHONE: (919) 832-2878 FAX: (919) 832-7901 ATTN: CARL WINSTEAD, AIA LANDSCAPE ARCHITECT- KIMLEY-HORN AND ASSOCIATES, INC. 333 FAYETTEVILLE STREET SUITE 600 RALEIGH, NC 27601 PHONE: (919) 653-2928 ATTN: BRANDON WHITE, RLA, ASLA SITE LIGHTING CRENSHAW CONSULTING ENGINEERS 3516 BUSH STREET RALEIGH, NC 27609 PHONE: (919) 871-1070 FAX: (919) 871-5620 ATTN: JIM CRENSHAW, P.E. PERMIT DOCUMENT SUBMITTAL FOR FT. BRAGG -FIRST CITIZENS BANK 2569 REILLY ROAD FORT BRAGG, NC PREPARED IN THE OFFICE OF: K 01 m I %e rtyo) H o r n © 2014 KIMLEY—HORN AND ASSOCIATES, INC. P.O. BOX 33068 - RALEIGH, NORTH CAROLINA 27636-3068 PHONE: (919) 677-2000 FAX. (919) 677-2050 NC LICENSE # F-0102 SHEET INDEX 1 Sheet Number Sheet Title CO.00 COVER SHEET CO.10 GENERAL NOTES CO.20 GENERAL NOTES C1.00 EXISTING CONDITIONS AND DEMOLITION PLAN C2.00 SITE PLAN C3.00 UTILITY PLAN C4.00 GRADING AND DRAINAGE PLAN C5.00 EROSION CONTROL PLAN C6.00 SITE DETAILS C7.00 SITE DETAILS C8.00 UTILITY DETAILS C9.00 UTILITY DETAILS C10.00 STORMWATER DETAILS C11.00 STORMWATER DETAILS C12.00 EROSION CONTROL DETAILS C13.00 EROSION CONTROL DETAILS L1.00 LANDSCAPE PLAN L2.00 LANDSCAPE DETAILS L3.00 LANDSCAPE SPECIFICATIONS X1 PRE —DEVELOPMENT DRAINAGE AREA X2 POST DEVELOPMENT DRAINAGE AREA 5 8/18/14 REVISED PER 12" WATERMAIN LOCATION 4 8/5/14 REVISED PER FT. BRAGG COMMENTS — RAY BARBEAU (8/5/2014) 3 7/7/14 REVISED PER FT. BRAGG COMMENTS — RAY BARBEAU (7/1/2014) 2 6/18/14 REVISED PER DPW COMMENTS — LEE WARD (6/12/14) 1 6/4/14 REVISED DRIVE—THRU WIDTHS PER OWNER REQUEST NO. DATE DESCRIPTION This document, together with the concepts and designs presented herein, as an instrum nt of services is intended only for the specific pi°oCW'e,'enfsiwas prepared. Reuse of andre'q"oogeesmNeate�eomt.lh'li,�cdorament without written outhoriz th nr on imi V ;thHeorn and Associates, Inc. shaHatRan4MW it ` I '� �orr and Associates, Inc. stommater rules. S1. NCAC2H.1008(j) Permit#.'S20W 0 Obi Date �,ZZ-_y by%�1�Q� NC Division of Water Quality Sheet # A61 Revision Date • Z8 - Copyright Kimley—Horn and Associates, Inc., 2014 DATE: MAY 14, 2014 HWj JOB NUMBER: '010 BJC BJC BJC DAW BY ► 1,14- 011737212 m w m ' c v n s=lT E DRAINAGE: STORM PIPE SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED: A MINIMUM GRADE OF 0.50% SHALL BE MAINTAINED ON ALL PIPES, UNLESS OTHERWISE NOTED. ALL PIPE LENGTHS AND SLOPES ARE APPROXIMATE. PRECAST STRUCTURES MAY BE USED AT CONTRACTORS OPTION. TYPE is RCP, CLASS III PER ASIM C-76,07H FLEXIBLE PLASTIC BITUMEN GASKETS AT JOINTS. TYPE 2: HIGH DENSITY POLYETHYLENE PIPE (HOPE) - AASHTO DESIGNATION M252 TYPE S. M294 TYPE S AND MP7-97 TYPE S. SMOOTH INTERIOR/ANNULAR EXTERIOR. ONLY PERMITTED WHEN SPECIFICALLY INDICATED ON THE CONSTRUCTION DRAWINGS. PIPE SHALL BE INSTALLED IN ACCORDANCE WITH PIPE MANUFACTURER'S INSTALLATION GUIDELINES. PIPE JOINTS AND FITTINGS SHALL CONFORM TO AASHTO M252 AND M294. ALL STORM DRAINAGE WITHIN THE PUBLIC ROADS SHALL BE CLASS III REINFORCED CONCRETE PIPE UNLESS SPECIFIED AS CLASS IV. ALL PIPES MALL BE LAID ON STRAIGHT ALIGNMENTS AND EVEN GRADES USING A PIPE LASER OR OTHER ACCURATE METHOD. EXISTING DRAINAGE STRUCTURES TO BE INSPECTED AND REPAIRED AS NEEDED, AND EXISTING PIPES TO BE CLEANED OUT TO REMOVE ALL SILT AND DEBRIS. UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A. NO MORE THAN 500 LF OF TRENCH MAY BE OPENED AT ONE TIME. B. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF -SITE PROPERTY. D. MATERIAL USED FOR BACK -FILLING TRENCHED SHALL BE PROPERLY COMPACTED IN ORDER TO MINIMIZE EROSION AND PROMOTE STABILIZATION. E. DESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE EROSION AND SEDIMENT CONTROL REGULATIONS. F. APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR BETTER. ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS WATERTIGHT. ALL STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT OUT. CATCH BASINS, MANHOLES, FRAMES, GRATES, ETC. SHALL MEET THE REQUIREMENTS OF THE LATEST EDITION OF THE NORTH CAROINA DEPARTMENT OF TRANSPORTATION (NCDOT) STANDARD DETAILS AND SPECIFICATIONS. ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH OATH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING & COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISH GRADE. LIDS SHALL BE LABELED 'STORM SEWER'. STRUCTURE TOP ELEVATIONS SHOWN HERE ARE APPROXIMATE. CONTRACTOR SHALL ADJUST AS NECESSARY. RIM ELEVATIONS AS SHOWN ON THE CONSTRUCTION DRAWINGS ARE TO THE GUTTER FLOW LINE. STORM SEWER OUTLETS ARE TO BE CUT OFF AND DIVERTED TO SEDIMENT BASINS UNTIL SITE IS STABILIZED. THEN FES AND RIP -RAP APRON MAY BE INSTALLED. ONUS WATER SERVICE NOTES: 1. ALL MATERIAL SHALL BE APPROVED BY ONUS. 2. SERVICE LATERAL SIZE 2" AND SMALLER SHALL BE CTS PE DR 9 OR PVC SDR 21 PIPE, UNLESS OTHERWISE SPECIFIED. 3. SERVICE LATER INSTALLATION SHALL BE APPROVED BY ONUS. 4. WATER SERVICE LOCK VALVE TO BE LOCATED 18" FROM SANITARY SEWER CLEAN OUT STACK WHEN INSTALLED IN SAME DITCH. 5. WHEN INSTALLED IN A PAVED AREA, METER BOX TO BE SET 1/4" ABOVE FINISHED PAVEMENT GRADES AND PAVEMENT FEATHERED TO TOP OF BOX TO PROVIDE DRAIN AWAY FROM BOX. 6. C.I. METER BOXES SHALL BE USED IN TRAFFIC AREAS (SEE STANDARD DETAIL). 7. PERIMETER SOLID CONCRETE BRICK BASE WITH NO GAPS, DO NOT LAY BRICK ON PIPE. 8. WHERE ASPHALT CURB OR STRIP PAVEMENT EXIST, THE LOCATION OF BOX SHALL BE AS DIRECTED BY ONUS REPRESENTATIVE. 9. DISTANCE FROM TOP OF LOCK VALVE OPERATING STEM TO TOP OF BOX SHALL BE 8" MIN. TO 10" MAX. 10. NON-RESIDENTIAL METER BOX SHALL BE SET 5' BACK FROM BACK OF CURB TO CENTERLINE OF METER BOX PERPENDICULAR TO THE CURBLINE. 11. COMMERCIAL METER BOX LOCATION SHALL BE AS APPROVED (PREFER NO METER BE INSTALLED LESS THAN 5' FROM BLDG. TO EDGE OF BOX). 12. LATERAL SHALL BE CENTERED ON LOT UNLESS OTHERWISE NOTED. 13. LATERAL SHALL NOT BE BACK FILLED UNTIL INSPECTED BY ONUS. 14. WATER MAIN AND LATERAL SHALL PASS HYDROSTATIC, LEAKAGE, AND STERILIZATION TESTS (200 PSI). 15. SHOULD IT BE NECESSARY TO CRIMP THE WATER SERVICE LATERAL, A FULL CIRCLE REPAIR CLAMP SHALL BE PLACED ON THE CRIMPED AREA. ONUS SEWER LATERAL NOTES: 1. CONTRACTOR SHALL SUBMIT TAPPING SADDLE SHOP DRAWING, IF USED, TO ENGINEER FOR APPROVAL. 2. HOLE IN SANITARY SEWER MAIN MUST BE CUT OATH SHELL CUTTER. NO HAMMER TAPS ALLOWED. 3. LATERAL SHALL CONFORM TO ASTM SPECS. D-3034 SDR-26 UNLESS OTHERWISE INDICATED AS DUCTILE IRON. 4. ALL PIPE AND FITTINGS SHALL BE 4' OR 6" UNLESS OTHERWISE SPECIFIED. 5. ALL D.I. PIPE SHALL HAVE AN INTERIOR LINING OF CERAMIC EPDXY OR FUSED CALCIUM ALUMINATE CEMENT WITH FUSED CALCIUM ALLUMINATE AGGREGATES. THE ENTIRE D.I. LATERAL SHALL BE COMPRISED OF D.I. PIPE AND MECHANICAL JOINT FITTINGS. 6. ALL CONNECTIONS SHALL HAVE RUBBER GASKET SEALS INSTALLED. 7. SANITARY SEWER SERVICE C/O STACK SHALL BE LOCATED 18" FROM WATER SERVICE LOCK VALVE WHEN IN SAME DITCH. 8. THE CONTRACTOR MAY USE A TAPPING SADDLE WITH STRAPS & ALIGNMENT FLANGE FOR CONNECTION TO PIPE. TAPPING SADDLES WITHOUT AN ALIGNMENT FLANGE VALE NOT BE ACCEPTABLE. 9. THE CONTRACTOR SHALL USE SDR 26 P.V.C. TEE FOR CONNECTION TO SDR 26 P.V.C. PIPE OR DI TEE FOR CONNECTION TO DUCTILE IRON PIPE. PVC TEE SHALL BE ONE PIECE MOLDED OR FABRICATED. TEE WYES AND TWO PIECE TEES ARE NOT ACCEPTABLE. 10. TAPPING PROCESS SHOWN SHALL BE USED FOR ALL SANITARY SEWER MAINS 11. SLOPE AND DEPTH OF THE SERVICE LATERAL SHALL BE DETERMINED BY THE TOPOGRAPHY OF THE LOT AS APPROVED BY THE ONUS ENGINEER OR AS INDICATED ON THE DRAWINGS. 12. LATERAL SHALL CONFORM TO THE 1/8" PER FOOT MINIMUM SLOPE. MAXIMUM CLEAN OUT SPACING FOR 4" PIPE 7V. 6" PIPE 100' 13. SEE INTERIOR DROP STRUCTURE OR SLIDE, MORTAR SLIDE & SHELF DETAIL FOR VERTICAL DROPS OF MAINS AND LATERALS. 14. LATERALS GREATER THAN 20' DEPTH SHALL UTILIZE DUCTILE IRON PIPE AND FITTINGS WITH CERAMIC EPDXY OR FUSED CALCIUM ALUMINATE CEMENT WITH FUSED CALCIUM ALUMINATE AGGREGATES 15. ENTIRE SEWER LATERAL ASSEMBLY SHALL BE AIR TESTED CONCURRENTLY WITH SEWER MAIN. 16. INDIVIDUAL LATERALS SHALL BE CLEANED AND FLUSHED PRIOR TO FLUSHING SANITARY SEWER MAINS. 17. LATERAL SHALL NOT BE BACK -FILLED UNTIL INSPECTED BY THE ONUS CONSTRUCTION COORDINATOR/ONUS INSPECTOR. 18. WYE CONNECTIONS SHALL NOT BE USED TO TIE LATERALS INTO A MANHOLE, UNLESS OTHERWISE APPROVED BY ONUS. 19. IF BENDS ARE APPROVED BY THE ENGINEER, NO BENDS GREATER THAN 45' ARE ALLOWED UNLESS APPROVED BY THE ENGINEER. STONE BEDDING IS REQUIRED TO BE INSTALLED FROM UNDISTURBED SOIL TO BOTTOM OF BEND. 20. PVC COMBINATION SHALL BE 2 PIECE TEE-WYE. GASKETED, SDR26, AS MANUFACTURED BY HARCO, GPK OR APPROVED EQUAL UTILITY NOTES: CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH FORT BRAGG PWBC, ONUS, AND NCDENR STANDARDS AND SPECIFICATIONS. ALL SEWER LATERALS SHALL BE PVC (SDR 26). ALL SEWER MAINS SHALL BE PVC (SDR 26). UNLESS OTHERWISE NOTED. WATER MAINS LARGER THAN 2" MALL BE CONSTRUCTED OF PVC 1120 (AWWA C-900) OR DUCTILE IRON PIPE. WATER MAINS 2" AND SMALLER SHALL BE POLYETHYLENE TUBING (SDR-9, AWWA C-901), PVC (C-900, SDR 14, PRESSURE CLASS 200) GALVANIZED STEEL PIPE (SCHEDULE 80) OR COPPER TUBING (TYPE K. ASTM B-88). LOCAT10N OF SEWER AND WATER SERVICES TO BUILDING IS SCHEMATIC. REFER TO ARCHITECTURAL PLANS FOR EXACT PLACEMENT OF SERVICES. SITE CONTRACTOR IS TO COORDINATE FINAL LOCATION AND ELEVATION OF UTILITY SERVICES WITH THE BUILDING CONTRACTOR. DUCTILE IRON PIPE IS REQUIRED FOR WATER MAINS IF A 12" MINIMUM CLEARANCE IS NOT MET BETWEEN WATER MAIN AND GAS MAINS, TELEPHONE DUCT BANKS, OR UNDERGROUND CABLES. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A WATER SERVICE LINE TO EACH UNIT. WATER SERVICE UNE SIZE AND ENTRY POINT IS AS SPECIFIED ON THE PLUMBING DRAWINGS (MINIMUM 1 INCH DIAMETER). CONNECTION POINTS FOR WATER SERVICE LINES ALONG THE MAIN SHALL BE FIELD LOCATED BY THE CONTRACTOR AND APPROVED BY PICERNE CONSTRUCTION. WATER SERVICE LINES SHALL EXTEND TO WITHIN 5 FEET OF EACH UNIT AND SHALL BE CAPPED AND STAKED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. WATER SERVICES SHALL ORDINARILY BE PLACED NO LESS THAN FIVE FEET HORIZONTALLY FROM SEWER SERVICES AND A MINIMUM OF 18 INCHES CLEAR ABOVE THE SEWER SERVICE. IF DUCTILE IRON OR PVC RUBBER GASKETED JOINT PIPE IS USED FOR THE SEWER SERVICE, THE WATER SERVICE MAY BE PLACED NOT LESS THAN 1.5 FEET CLEAR HORIZONTALLY AND ONE FOOT CLEAR ABOVE THE SEWER SERVICE. FLUSHING AND PRESSURE TESTING OF ALL NEW MAINS IN ACCORDANCE WITH AWWA STANDARD C600 IS REQUIRED. DISINFECTION AND BACTERIA SAMPLING OF ALL NEW WATER MAINS IN ACCORDANCE WITH AWWA STANDARD C651 IS REQUIRED. NEW MAINS SHALL NOT BE PLACED IN SERVICE UNTIL WRITTEN ACCEPTANCE FROM NCDENR IS RECEIVED BY ONUS. PRESSURE REDUCING VALVES WILL BE REWIRED ON THE DOMESTIC WATER MAINS IF THE STATIC PRESSURE AT THE BUILDING EXCEEDS 8OPS. SANITARY SEWER SLOPES SHOWN WITHIN THESE PLANS ARE FOR CONTRACTOR REFERENCE ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING THE SEWER TO THE INVERTS SHOWN ON THIS PLAN. THE MINIMUM SLOPE FOR AN 8" SANITARY SEWER IS 0.40X THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A SANITARY SEWER SERVICE LINE TO EACH UNIT. SANITARY SEWER SERVICE LINE SIZE AND ENTRY POINT IS AS SPECIFIED ON THE PLUMBING DRAWINGS (MINIMUM 4 INCH DIAMETER). CLEANOUTS SHALL BE PROVIDED FOR ALL BUILDING SERVICE CONNECTIONS AT THE BUILDING IN AN ACCESSIBLE LOCATION. CLEANOUTS SHALL NOT BE LOCATED IN DRIVEWAYS, SIDEWALKS OR WALKWAYS. A CLEANOUT SHALL BE PLACED AT EACH HORIZONTAL OR VERTICAL DEFLECTION. CLEANOUTS FOR SERVICE CONNECTIONS SHALL BE A MINIMUM OF 4FT BELOW FLOOR FFE. SANITARY SEWER SERVICE LINES SHALL EXTEND TO CLEAN OUT FOR EACH UNIT AND SHALL BE CAPPED AND STAKED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. THE TOP ELEVATION OF ALL MANHOLES IN PAVED AREAS SHALL MATCH FINISH GRADE. THE TOP ELEVATION OF ALL MANHOLES IN GRASSED AREAS SHALL BE MINIMUM 1-FOOT ABOVE ALL FINISH GRADE UNLESS DIRECTED OTHERWISE BY OWNER. THE SITE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL UNDERGROUND UTLITES WITH SITE WORK SUCH THAT UNDERGROUND UTILITIES ARE IN PLACE PRIOR TO PLACEMENT OF GRAVEL BASE COURSE MATERIAL COORDINATE WITH PICERNE FOR LOCATIONS OF ELECTRIC AND GAS SERVICE CONNECTIONS. UGE/T/C/G CORRIDOR LOCATIONS ARE APPROXIMATE. COORDINATE WITH UTILITY PROVIDER AND OWNER PRIOR TO UTILITY INSTALLATION. CONTRACTOR SHALL VERIFY THE LOCATION AND THE SIZE OF ANY DRAINAGE STRUCTURES PRIOR TO CONSTRUCTION. ALL DUCTILE IRON PIPE AND FITTINGS MEET THE FOLLOWING STANDARDS: 1. MANUFACTURED IN STRICT ACCORDANCE WITH ANSI A21.51 AND AWWA C151 2. CLASS 50 OR CLASS 51. AS APPLICABLE 3. THE WORKING PRESSURE SHALL BE A MINIMUM OF 200 PSI 4. PUPE SHALL BE FURNISHED IN 18' OR 20' LENGTHS 5. DUCTILE IRON PIPE DESIGNATED AS 'PRESSURE CLASS' SHALL BE SUBJECT TO THE ENGINEER'S APPROVAL 6. ALL PIPE JOINTS USED IN OPEN TRENCH CONSTRUCTION SHALL BE FURNISHED WITH "PUSH -ON" JOINTS. UNLESS OTHERWISE INDICATED ON THE DRAWINGS OR SPECIFIED 7. ALL JOINTS AND FITTINGS SHALL BE IN ACCORDANCE WITH ANSI A21.11 AND AWWA C111 B. ALL DUCTILE IRON INTERIOR SURFACES SHALL BE LINED WITH TWO COATS OF CERAMIC EPDXY TO PRODUCE A TOTAL MINIMUM DRY FILM THICKNESS OF 40 MILS 9. THE EXTERIOR PIPE SURFACES SHALL BE PROTECTED WITH ASPHALTIC COATING AS SPECIFIED IN AWWA C151 AND 1C110 CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND ASSURING THAT EXISTING UTILITIES ARE LOCATED PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL 811 AND PWBC 48 HOURS PRIOR TO THE COMMENCEMENT OF WORK FOR UTILITY LOCATING SERVICES. THE CONTRACTOR SHALL PROVIDE A SURVEY AS -BUILT RECORD DRAWING OF THE SANITARY SEWER SYSTEM AND THE WATER DISTRIBUTION SYSTEM IN ACCORDANCE WITH FORT BRAGG PWBC, ONUS, AND NCDENR REQUIREMENTS. IN AREAS WHERE UTILITY LINES OR SERVICES CROSS UNDER THE CURB THE CONTRACTOR SHALL CUT/STAMP INTO THE CURB THE FOLLOWING LETTERS TO RECORD THE LOCATION OF THE UTILITY CROSSING: W - WATER DISTRIBUTION V - WATER DISTRIBUTION VALVE S - SANITARY SEWER X - UTILITY CROSSING ONUS FIRE HYDRANT NOTES: 1. PROPOSED FIRE HYDRANTS SHALL BE INSTALLED IN ADVANCE OF SEWER MAIN CONSTRUCTION. THE CONTRACTOR SHALL SEQUENCE THE HYDRANT INSTALLATION TO PROVIDE AND/OR SUPPLEMENT WATER MAIN FLUSHING IF BREAKS OCCUR. 2. FIRE HYDRANT CONNECTIONS TO EXISTING WATER MAINS SHALL BE MADE USING A TAPPING SLEEVE AND VALVE BY WET TAP CONNECTION. THE TAPPING SLEEVE AND VALVE SHALL BE PRESSURE TESTED PRIOR TO AND AFTER THE COMPLETION OF THE TAP IN THE PRESENCE OF THE ENGINEER OR ONUS CONSTRUCTION COORDINATOR. TAPPING SLEEVE SHALL BE FILLED WITH WATER PRIOR TO PRESSURIZATION FOR SAFETY PURPOSES. 3. THE CONTRACTOR SHALL HAVE THE EXISTING UTILITIES LOCATED IN THE VICINITY OF THE PROPOSED FIRE HYDRANT PRIOR TO REQUESTING CONSTRUCTION STAKES. THE PROPOSED LOCATION MAY BE SHIFTED OR RELOCATED BY THE ENGINEER IF CONFLICTS EXIST (I.E. GAS SERVICES, UGE TELEPHONE, ETC.). 4. THE CONTRACTOR SHALL VERIFY (BY DIGGING), IN ADVANCE OF INSTALLATION AND MATERIAL PROCUREMENT, THE EXISTNG WATER MAIN MATERIAL, SIZE, CLASS, DEPTH, AND LOCATION FOR EACH INDIVIDUAL FIRE HYDRANT LOCATION IN ORDER TO SUPPLY PROPER SLEEVE TYPES, BARREL LENGTHS, AND OTHER REQUIRED MATERIALS TO ACCOMMODATE EXISTING MATERIALS ENCOUNTERED AND SITE CONDITIONS. 5. THE CONTRACTOR WALL BE REWIRED TO SUPPLY VARIOUS LENGTHS OF BARRELS AND HYDRANT EXTENSIONS TO ADJUST FOR WATER MAIN DEPTHS IN RELATION TO TOP OF EXISTING CURB GRADE, TOP OF PAVEMENT, EXISTING DITCH GRADE, AND/OR RIGHT-OF-WAY GROUND ELEVATIONS AS NECESSARY. ADDITIONAL FITTINGS AND/OR HYDRANT EXTENSIONS OR OFFSET CONNECTORS MAY BE REQUIRED TO MAINTAIN PROPER COVER. (NO SEPARATE PAY). 6. FIRE HYDRANT SHALL BE INSTALLED IN ACCORDANCE WITH THE FIRE HYDRANT AND VALVE INSTALLATION DETAIL 7. THE CONTRACTOR SHALL SUBSTITUTE VARIOUS BARREL DEPTHS WITHIN THE PROJECT (I.E. FIRE HYDRANT NO. 1 INDICATES A 5'-0" DEPTH OF BURY, ACTUAL CONDITIONS CALL FOR A 6'-0" DEPTH OF BURY, FIRE HYDRANT NO. 2 INDICATES A 6' DEPTH OF BURY ACTUAL CONDITIONS REWIRE A 5' DEPTH OF BURY, THEN A SUBSTITUTION WALL BE REQUIRED). ALL EXTENSIONS SHALL BE APPROVED BY THE ONUS CONSTRUCTON COORDINATOR. PRIOR TO INSTALLATON AND ONLY AFTER ALL EFFORTS OF SUBSTITUTION ARE EXHAUSTED. B. WHERE INDICATED TO TIE EXISTING FIRE HYDRANT TO NEW MAIN, CONTRACTOR SHALL PROVIDE ALL LABOR, TOOLS, EQUIPMENT, MATERIALS, ETC. NECESSARY TO PROVIDE A COMPLETE INSTALLATION. FIRE HYDRANT SHALL BE TRANSFERRED TO NEW MAIN BRANCH LINE AFTER MAIN IS ACCEPTED. HYDRANTS SHALL NOT BE OUT OF SERVICE FOR GREATER THAN 24 HOURS. CONTRACTOR SHALL NOTIFY FORT BRAGG FIRE DEPARTMENT OF OUT OF SERVICE FIRE HYDRANTS PRIOR TO CONSTRUCTION. 9. SOD OR SEEDING SHALL BE REPLACED WHERE APPLICABLE. DAMAGE TO LANDSCAPING, FENCES, ETC. SHALL BE REPAIRED OR REPLACED TO THE PROPERTY OWNER'S SATISFACTION, TO INCLUDE WITHIN RIGHT-OF-WAY. (NO SEPARATE PAYMENT). 10. THE UNIT PRICE BID SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, TESTING, FIELD INVESTIGATION, UTILITY LOCATIONS, AND ANY AND ALL OTHER INCIDENTALS REQUIRED FOR PROPER FIRE HYDRANT INSTALLATION INCLUDING BUT NOT LIMITED TO FIRE HYDRANT MATERIALS AND LABOR, VARIOUS BARREL DEPTHS, EXTENSIONS. OFFSET CONNECTORS, TAPPING SLEEVE, TESTING, TAPPING VALVE, TAPPING OF EXISTING MAIN, FITTINGS, TRAFFIC CONTROL AND SIGNAGE, SOD, SEEDING, PAVEMENT REPAIR, REMOVING AND REPLACING PAVEMENT, PAINTING IN ACCORDANCE WITH ONUS STANDARDS, REMOVING AND REPLACING LANDSCAPING AND EXISTNG FEATURES, ADJUSTMENTS REWIRED DUE TO EXISTING UTILITY CONFLICTS, EROSION AND SEDIMENT CONTROL MEASURES, REPAIRING AND/OR REPLACING ALL DAMAGES, FIELD INVESTIGATIONS AND ALL ELSE REQUIRED FOR COMPLETE INSTALLATION. 11. CONTRACTOR SHALL INSTALL CAPIVATOR LOCKING NOZZEL AND STEAMER CAPS ON ALL NEW INSTALLATIONS AND NOTIFY ONUS OF THE NEW FIRE HYDRANT LOCATION. 12. HYDRANTS SHALL BE PAINTED CHROME YELLOW IN COLOR NTH MATCHING CHROME YELLOW CAPTIVATOR CAPS. n n n51 K'mlevio)iHorn N 0 © 2014 KIMLEY-HORN AND ASSOCIATES, INC. 333 FAYETTEVILLE STREET, SUITE 600, RALEIGH, NC 27601 PHONE: 919-835-1494 FAX: 919-653-5847 INo. REVISIONS DATE BY WWW.KIMLEY-HORN.COM NC LICENSE #F-0102 i KHA PROJECT 011737212 DATE 5/14/14 SCALE AS SHOWN DESIGNED BY PAB DRAWN BY DAW CHECKED BY PAB ONUS WATER AND SEWER NOTES: 1. ALL MATERIALS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH ONUS STANDARDS, DETAILS, & SPECIFICATIONS. 2. UTILITY SEPARATION REQUIREMENTS: A. WHEN INSTALLING WATER AND/OR SEWER MAINS, THE HORIZONTAL SEPARATION BETWEEN UTILITIES SHALL BE 10'. IF THIS SEPARATION CANNOT BE MAINTAINED DUE TO EXISTING CONDITIONS, THE WATER MAIN SHALL BE IN A SEPARATE TRENCH WITH THE ELEVATION OF THE WATER MAIN AT LEAST 18' ABOVE THE TOP OF THE SEWER. ALL DISTANCES ARE MEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER. B. WHERE IT IS IMPOSSIBLE TO OBTAIN PROPER SEPARATION, OR ANY TIME A SANITARY SEWER CROSSES OVER A WATER MAIN, DIP MATERIALS OR STEEL ENCASEMENT EXTENDED 10' ON EACH SIDE OF CROSSING MUST BE SPECIFIED AND INSTALLED TO WATERLINE SPECIFICATIONS. C. MAINTAIN 18' MIN. VERTICAL SEPARATION AT ALL WATER MAIN AND STORM DRAIN CROSSINGS, WHERE ADEQUATE SEPARATION CANNOT BE ACHIEVED, SPECIFY DIP MATERIALS AND A STONE CRADLE. D. ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER AND SEWER FACILITIES WITH 18" MIN. VERTICAL SEPARATION. 3. ANY NECESSARY FIELD REVISIONS SHALL BE REVIEWED AND APPROVED PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL MAINTAIN CONTINUOUS WATER AND SEWER SERVICE TO EXISTING RESIDENCES & BUSINESSES THROUGHOUT CONSTRUCTION OF PROJECT. ANY NECESSARY SERVICE INTERRUPTIONS SHALL BE PRECEDED BY A 2-WEEK ADVANCE NOTICE. 5. 3.0' MINIMUM COVER ISREQUIREDABOVE ALL WATER MAINS AND SEWER FORCE MAINS IF THIS COVER CANNOT BE MET THEN THE SANITARY SEWER LINE SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE. IN TRAFFIC AREAS THESE PIPES SHALL BE DESIGNED FOR TRAFFIC LOADS. 6. ALL ENVIRONMENTAL PERMITS APPLICABLE TO THE PROJECT MUST BE OBTAINED FROM NCDENR, USACE, FT. BRAGG, AND/OR FEMA FOR ANY RIPARIAN BUFFER, WETLAND, AND/OR FLOODPLAIN IMPACTS (RESPECTIVELY) PRIOR TO CONSTRUCTION. 7. NCDOT ENCROACHMENT AGREEMENTS ARE REQUIRED FOR ANY UTILITY WORK (INCLUDING MAIN EXTENTIONS AND/OR SERVICE TAPS) WITHIN STATE RIGHT-OF-WAY PRIOR TO CONSTRUCTION. 8. REDUCED PRESSURE BACKFLOW PREVENTION ASSEMBLIES ARE REQUIRED ON ALL COMMERCIAL SERVICES AND FIRE SERVICES. THE DEVISES SHALL MEET AMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE) STANDARDS. THE ASSEMBLIES SHALL BE INSTALLED AND TESTED (BOTH INITIAL AND PERIODIC TESTING THEREAFTER) IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR THE LOCAL CROSS -CONNECTION CONTROL PROGRAM, WHICHEVER IS MORE STRINGENT. 9. CONTRACTOR SHALL REPAIR ALL WATER LATERALS, AND MAINS DAMAGED DURING CONSTRUCTION (NO SEPARATE PAYMENT). THE CONTRACTOR SHALL REPORT IMMEDIATELY ALL WATER MAIN AND LATERAL BREAKS TO DPW SERVICE DESK AT (910) 396-0324 AND TO ONUSS REPRESENTATIVE AND SHALL INITIATE IMMEDIATE REPAIRS TO ONUS STANDARDS. CONTRACTOR SHALL NOT OPERATE ONUS WATER MAIN VALVES OR HYDRANTS WITHOUT ONUS APPROVAL AND SHALL COORDINATE ALL VALVE CLOSINGS WITH ONUS. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE WATER SYSTEM IN THE AREA SO AS TO LESSEN THE CHANCE OF SERVICE INTERRUPTION. 10. THE CONTRACTOR SHALL NOT USE HOUSE HOSE BIBS OR ANY OTHER METHOD OF BLOW OFF WHICH ALLOWS DOMESTIC WATER CONTAINING SEDIMENTS OR HIGH LEVELS OF CHLORINE TO PASS THRU RESIDENTS' SERVICES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES RESULTING FROM ALLOWING 'DIRTY WATER TO ENTER RESIDENT'S PLUMBING SYSTEM, SUCH AS WATER HEATERS, STAINED CLOTHING, CLOGGED SCREENS, ETC. 11. WHERE PLANS INDICATE EXISTING WATER VALVE TOP/RIM AND INVERT, THE INVERT IS THE ELEVATION OF THE TOP OF THE VALVE OPERATING NUT. 12. DUE TO THE QUESTIONABLE INTEGRITY OF THE EXISTING WATER SYSTEM AS RELATING TO NEW CONSTRUCTION, CONTRACTOR SHALL INSTALL NEW WATER AND TRANSFER ALL SERVICES PRIOR TO BEGINNING SANITARY SEWER CONSTRUCTION. THIS MAY BE ACCOMPLISHED STREET BY STREET TO ALLOW SIMULTANEOUS WATER AND SEWER CONSTRUCTION. WATER SHALL BE INSTALLED UTILIZING AN ONUS APPROVED CUT -SHEET INDICATING WATER MAIN INSTALLATION DEPTH BELOW ENGINEER SUPPLIED REFERENCE POINTS. 13. CLEANOUT ELEVATIONS AND/OR LOCATIONS MAY BE ADJUSTED IN THE FIELD AS DIRECTED BY THE ENGINEER WHEN NECESSARY. CLEANOUT STACK TOP ELEVATION IS DETERMINED BY INTERPOLATING FIELD DATA AND MAY NOT BE EXACT. CLEANOUT ELEVATION TOP SHALL BE SET IN ACCORDANCE WITH THE TYPICAL DETAIL FOR ONUS. (NO SEPARATE PAYMENT). 14. WHERE SANITARY SEWER MAINS ARE TO BE CONSTRUCTED WITHIN 20' OF EXISTING RESIDENCES, SPECIAL CONSIDERATION SHALL BE GIVEN TO MINIMIZE UNDERMINING OR OTHERWISE DISTURBING EXISTING RESIDENCES ADJACENT TO THE SEWER MAIN. THE CONTRACTOR SHALL USE A RUBBER TIRED BACK HOE AND NO MECHANICAL COMPACTION EQUIPMENT IN THESE AREAS. THE TRENCH SHALL BE SHORED ADEQUATELY TO PREVENT ANY IMPACT FROM THE SIDE SLOPES. SUITABLE BACK FILL SHALL BE PLACED IN THE TRENCH. CONTRACTOR SHALL REFER TO THE GEOTECHNICAL REPORT AND FOLLOW RECOMMENDATONS. CONSTRUCTION METHODS AND MEASURES SHALL BE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT AND RECOMMENDATIONS. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR REPAIR OF STRUCTURES, FOUNDATIONS, FOOTINGS, ETC. DAMAGED DUE TO CONSTRUCTION. 15. CONTRACTOR SHALL COORDINATE WITH ONUS ANY SCHEDULED CONSTRUCTION OR DISTURBANCES WHICH WOULD IMPACT EXISTING STRUCTURES OR FUNCTIONAL USE OF UTILITY SEWERS TO THOSE STRUCTURES. 16. MANHOLE COVERS ALONG STREETS AND HEAVILY TRAVELED AREAS SHALL BE VENTED AND UNLOCKED. MANHOLE COVERS ON OUTFALLS AND IN NON -TRAVEL AREAS SHALL BE VENTED AND BOLTED CLOSED. VENT PIPES SHALL BE INSTALLED ON OUTFALLS WHERE NON -VENTED MANHOLE COVERS ARE USED. 17. DUE TO THE QUESTIONABLE INTEGRITY OF THE EXISTING WATER SYSTEM AS RELATING TO NEW CONSTRUCTION, CONTRACTOR SHALL INSTALL NEW WATER AND TRANSFER ALL SERVICES PRIOR TO BEGINNING SANITARY SEWER CONSTRUCTION. THIS MAY BE ACCOMPLISHED STREET BY STREET TO ALLOW SIMULTANEOUS WATER AND SEWER CONSTRUCTION. WATER SHALL BE INSTALLED UTILIZING A ONUS APPROVED CUT -SHEET INDICATING WATER MAIN INSTALLATION DEPTH BELOW ENGINEER SUPPLIED REFERENCE POINTS. 18. TRANSFER OF WATER SERVICES SHALL BE ACCOMPLISHED AS FOLLOWS: A. INSTALL, TEST AND STERILIZE NEW MAIN AND LATERALS. LATERALS SHALL BE INSTALLED ADJACENT TO EXISTING SERVICE (EXISTING SERVICE IS ACTIVE). B. TRANSFER EXISTING METER TO NEW METER BOX AND TIE NEW WATER LATERAL TO EXISTING DOMESTIC SERVICE. BLOW -OFF SERVICE AT HOSE BIB ON HOUSE ONLY IF EXISTING METER HAS NO LOCK VALVE OR IS INOPERABLE. WHEN MAIN IS NOT TO BE ABANDONED, CONTRACTOR SHALL UNCOVER OLD CORPORATION AT MAIN AND CLOSE CORPORATION TO ABANDON OLD SERVICE. (NO SEPARATE PAYMENT). C. AFTER ALL SERVICES ARE TRANSFERRED TO THE NEW SYSTEM IN A STREET OR VALVE TO VALVE, CUT OFF VALVE ON EXISTING SYSTEM AND ABANDON EXISTING MAINS AS INDICATED IN THE PLANS. D. CONTRACTOR SHALL SUPPLY NEW METER BOXES AND DISPOSE OF UNSUITABLE EXISTING METER BOXES. SALVAGEABLE METER BOXES SHALL BE DELIVERED TO ONUS. E. CONTRACTOR SHALL CHANGE OVER OLD METER TO NEW SERVICES OR INSTALL NEW METER APPROVED BY ONUS. METER NUMBER SHALL BE INSTALLED ON SAME ADDRESS AND/OR CUSTOMER. PROVIDE METER NUMBER AND ADDRESS TO ONUS. ONUS BACKFLOW PREVENTION NOTES: 1. THE BACKFLOW PREVENTER SHALL BE INSTALLED 5' FROM THE WATER METER. THE BACKFLOW PREVENTER SHALL NOT BE INSTALLED CLOSER THAN 5' FROM ANY BUILDING FOUNDATON. 2. REDUCED PRESSURE PRINCIPLE ASSEMBLIES MUST BE INSTALLED IN A HORIZONTAL POSITION AND IN A LOCATON IN WHICH NO PORTION OF THE ASSEMBLY CAN BECOME SUBMERGED UNDER ANY CIRCUMSTANCES. 3. REDUCED PRESSURE PRINCIPLE AND DOUBLE CHECK VALVE BACKFLOW PREVENTERS MUST BE INSTALLED ABOVE GROUND. 4. BACKFLOW PREVENTION ASSEMBLIES OUTSIDE AND ABOVE GROUND MUST BE PROTECTED FROM FREEZING WITH AN APPROVED FIBERGLASS OR ALUMINUM ENCLOSURE THAT RESTS UPON A MINIMUM 4 INCH CONCRETE PAD. THE BACKFLOW PREVENTION ASSEMBLY MUST BE INSTALLED BETWEEN MINIMUM AND MAXIMUM DISTANCES ABOVE THE CONCRETE PAD OF 12 INCHES AND 36 INCHES RESPECTIVELY WITH A MINIMUM CLEARANCE OF 24 INCHES ON 4 SIDES. LANDSCAPING IS ALLOWED AROUND THE BACKFLOW PREVENTOR BUT MUST NOT INTERFERE WITH THE REQUIRED ANNUAL TESTING, AND/OR REPAIR OF THE BACKFLOW PREVENTION ASSEMBLY. ROOT STRUCTURES OF PLANTINGS MUST BE GREATER THAN 18 INCHES BELOW THE SURFACE. 5. BACKFLOW PREVENTION ASSEMBLIES 2.5" AND LARGER MUST BE SUPPORTED TO ALLOW FOR THE WEIGHT OF THE BACKFLOW PREVENTION ASSEMBLY. SUPPORT AND FOOTING CONSTRUCTION MUST BE OF TYPE AND MATERIAL SUFFICIENT TO SUPPORT THE ASSEMBLY. SUPPORTS MUST HAVE A PROPER FOOTING (4 INCHES OF CONCRETE) FOR SUPPORTS TO REST UPON. BACKFLOW PREVENTION ASSEMBLY SUPPORTS MUST NOT INTERFERE WITH THE OPERATION OF VALVES, TEST COCKS, TESTING, AND/OR REPAIR OF THE BACKFLOW PREVENTION ASSEMBLY. 6. ALL PIPING LARGER THAN 2.5" IN DIAMETER MUST BE OF DUCTILE IRON OR STEEL 7. BEFORE STARTING INSTALLATION OF A BACKFLOW PREVENTER, CONTACT OLD NORTH UTILITY SERVICES TO ENSURE THE PROPER INSTALLATION OF THE BACKFLOW PREVENTION ASSEMBLY AND ENSURE THAT THE BACKFLOW PREVENTER MEETS THE CURRENT ONUS APPROVAL UST, AS SPECIFIED. 8. ALL ASSEMBLIES FOR USE IN THE ONUS SYSTEM SHALL MEET MANUFACTURER QUALITY ASSURANCES, AS STATED IN THE SPECIFICATIONS. TO BE AN APPROVED ASSEMBLY, THE BACKFLOW ASSEMBLY MUST BE SHIPPED FROM THE MANUFACTURER AS ONE UNIT. 9. BACKFLOW PREVENTION ASSEMBLIES TWO INCHES AND SMALLER SHALL HAVE 1/4 TURN, FULL PORT, RESILIENT SEATED. BRONZE BALL VALVE SHUT-OFF. 10. ASSEMBLIES TWO AND ONE HALF INCH (2-1/2)INCHES AND LARGER SHALL HAVE RESILIENT WEDGE SHUT-OFF VALVES: THE BACKFLOW PREVENTER AND RESILIENT WEDGE SHUT-OFF VALVES MUST BE FUSE BONDED EPDXY COATED. 11. HEATING EQUIPMENT SHALL BE FURNISHED AND DESIGNED BY THE MANUFACTURER OF THE ENCLOSURE, TO MAINTAIN AN INTERIOR TEMPERATURE OF +40' F WITH AN EXTERIOR/OUTSIDE TEMPERATURE OF -307 AND A WIND VELOCITY OF 15 MPH. HEATING EQUIPMENT SHALL BE U.L CERTIFIED. 12. ELECTRIC POWER SOURCE FOR HEAT AND ACCESSORIES SHALL BE GFI U.L APPROVED WITH MIN. 18" CLEARANCE TOP OF SLAB TO RECEPTACLE. 13. TEST COCKS MUST BE RESILIENT SEATED, FULLY PORTED, OPERATING STEM MUST INDICATE IF TEST COCK IS OPEN/CLOSED, OPERATING STEM ON A BALL VALVE TYPE OF TEST COCK MUST BE 'BLOWOUT PROOF' AND BODY MATERIALS MUST BE SPECIFIED AS BRONZE, STAINLESS STEEL OR ENGINEERED PLASTIC. 14. ALL NEW INSTALLATIONS SHALL CONFORM TO THE ONUS STANDARDS AND SELECTION OF ASSEMBLY TYPE SHALL BE BASED UPON DEGREE OF HAZARD AND TYPE OF FACILITY. FT. BRAGG, NORTH CAROLINA PREPARED FOR FIRST CITIZENS BANK DEMOLITION NOTES: THE CONTRACTOR SHALL COORDINATE ALL REMOVAL EFFORTS WITH THE OWNER. COORDINATION ITEMS ARE ANTICIPATED TO INCLUDE SITE ACCESS, TRAFFIC CONTROL, MAINTENANCE OF ACCESS AND UTILITIES FOR EXISTING BUILDINGS TO REMAIN, AND EROSION CONTROL ALL DEMOLITION AND REMOVAL EFFORTS SHALL BE PERFORMED IN ACCORDANCE WITH THE DEMOLITION SPECIFICATIONS FOR THIS PROJECT. ALL FEATURES MARKED TO BE ABANDONED IN PLACE SHALL REMAIN IN EXISTING CONDITION UNLESS REMOVED THROUGH EFFORTS FOR OTHER FEATURES. SPECIAL CARE SHALL BE TAKEN TO PROTECT AND MAINTAIN ALL EXISTING FEATURES NOT MARKED FOR REMOVAL IN THE EVENT OF ANY IMPACT TO SUCH FEATURES, THE CONTRACTOR SHALL PERFORM REPAIR AND/OR RESTORATION TO ORIGINAL CONDITION AS OF START OF WORK. WHERE PAVEMENT REMOVAL AREAS ABUT OTHER PAVEMENT AREAS TO REMAIN, THE EXISTING PAVEMENT SHALL BE SAW CUT TO PROVIDE A BOUNDARY WHICH IS STRAIGHT AND CLEAN IN APPEARANCE. ALL SANITARY SEWER MAIN FEATURES WILL GENERALLY BE PROTECTED IN PLACE UNLESS SPECIFICALLY MARKED FOR REMOVAL THE CONTRACTOR SHALL PROPERLY AND LEGALLY DISPOSE OF ALL DEMOLITION DEBRIS OFF OF THE CONSTRUCTION SITE. TREE PROTECTION NOTES: THE CONTRACTOR SHALL PROTECT ALL TREES AND SHRUBS OUTSIDE OF CUT/FILL LINES, IN ADDITION TO THOSE THAT RECEIVE TREE/SHRUB PROTECTION BARRIERS. THE CONTRACTOR IS ALSO REQUESTED TO SAVE ALL OTHER EXISTING TREES AND SHRUBS WHERE POSSIBLE. WHEN ROOT PRUNING IS NECESSARY, CUT ROOTS CLEANLY USING A DISC TRENCHER AND IMMEDIATELY COVER ALL ROOT CUT SURFACES LARGER THAN TWO INCHES IN DIAMETER WITH TREE WOUND DRESSING. USE PLYWOOD FORMS WHEN TREE ROOTS ARE ADJACENT TO PROPOSED CURB & GUTTER OR SIDEWALK. NO SOIL DISTURBANCE OR COMPACTION, CONSTRUCTION MATERIALS, TRAFFIC, BURIAL PITS, TRENCHING OR OTHER LAND DISTURBING ACTIVITY ALLOWED IN THE TREE PROTECTION ZONE. TREE BARRICADES MUST BE INSTALLED BEFORE ANY DEMOLITION, GRADING OR CONSTRUCTION BEGINS, AND NOT REMOVED UNTIL FINAL INSPECTION. NO GRUBBING WITHIN TREE PROTECTION ZONE. LEAVE SOIL AND LEAF UTTER UNDISTURBED. SUPPLEMENT WITH 1-2 INCHES OF MULCH. RE -SEED WITH GRASS ONLY IN DISTURBED/GRADED AREAS. TREE BARRICADES MUST BE INSTALLED BEFORE ANY DEMOLITION, CLEARING, GRADING OR CONSTRUCTION BEGINS AND IS NOT TO BE REMOVED UNTIL AFTER CONSTRUCTION. TREE PROTECTION FENCE IS TO BE LOCATED 1 FOOT PER TREE DIAMETER INCH AWAY FROM THE TREE. SEEDBED PREPARATION: GRADED SLOPES AND FILL - THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE WHICH CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED SHALL, WITHIN 21 WORKING DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. GROUND COVER - WHENEVER LAND DISTURBING ACTIVITY IS UNDERTAKEN, A GROUND COVER SUFFICIENT TO RESTRAIN EROSION MUST BE PLANTED OR OTHERWISE PROVIDED WITHIN 21 CALENDER DAYS OF COMPLETION OF ANY PHASE OF GRADING. SURFACE WATER CONTROL MEASURES TO BE INSTALLED ACCORDING TO THE PLANS. AREAS TO BE SEEDED SHALL BE RIPPED AND SPREAD WITH AVAILABLE TOPSOIL 4" DEEP. TOTAL SEEDBED PREPARED DEPTH SHALL BE 4" TO 8" DEEP. LOOSE ROCKS, ROOTS, AND OTHER OBSTRUCTIONS SHALL BE REMOVED FROM THE SURFACE SO THAT THEY WILL NOT INTERFERE MATH ESTABLISHMENT AND MAINTENANCE OF VEGETATION. SURFACE FOR FINAL SEEDBED PREPARATION, AT FINISH GRADES SHOWN, SHALL BE REASONABLY SMOOTH AND UNIFORM. IF NO SOIL TEST IS TAKEN, FERTILIZER AND LIME SHALL BE ACCORDING TO SEEDING SPECIFICATIONS. IF SOIL TEST IS TAKEN, PROVIDE UME AND FERTILIZER ACCORDING TO THE SOIL TEST REPORT. UME AND FERTILIZER SHALL BE APPLIED UNIFORMLY AND MIXED WITH THE SOIL DURING SEEDBED PREPARATION. FT. BRAGG SEEDING SPECIFICATIONS: 1. AREA WILL BE TILLED TO 4" DEPTH 2. APPLY UME AT 50 LBS PER 1000 SQUARE FT OR 1 TON PER ACRE 3. APPLY 10-20-20 FERTILIZER AT A RATE OF 850 LBS PER ACRE OR 20 LBS PER 1000 SQUARE FT. THE FERTILIZER SHOULD EITHER BE SLOW TIME RELEASE OR APPLIED IN TWO APPLICATIONS, 1/2 AT TIME OF PLANTING AND THE SECOND 1/2 AFTER PERMANENT SEED GERMINATES. 4. THE UME AND FERTILIZER WALL BE WORKED INTO THE TOP 2 INCHES OF SOIL PRIOR TO SEEDING. 5. SEED MIX AND RATE; "COOL SEASON": PLANTED BETWEEN 1 SEPTEMBER AND FEBRUARY 28 50 LBS PER ACRE SOFT RED WINTER WHEAT. "NO RYE GRASS' 25 LBS PER ACRE COMMON BERMUDA (CYNODON DACTYLON), HULLED 15 LBS PER ACRE COMMON BERMUDA (CYNODON DACTYLON), UNHULLED 'WARM SEASON': PLANTED BETWEEN 1 MARCH AND 31 AUGUST 50 LBS PER ACRE GERMAN (SETARIA ITAUCA), BROWN TOP (SETARIA ITAUCA), OR FOX TAIL MILLET (BRACHARIA RAMOSUM) 50 LBS PER ACRE COMMON BERMUDA (CYNODON DACTYLON), HULLED 'COOL SEASON': PLANTED BETWEEN 1 SEPTEMBER AND FEBRUARY 28 120 LBS PER ACRE SOFT RED WINTER WHEAT. "WARM SEASON': PLANTED BETWEEN 1 MARCH AND 31 AUGUST 65 LBS PER ACRE GERMAN (SETARIA ITALICA), BROWN TOP (SETARIA ITAUCA), OR FOX TAIL MILLET (BRACHARIA RAMOSUM) STRAW MULCH: 4,000 LBS PER ACRE. THE GROUND SHOULD BE COMPLETELY COVERED WITH NO BARE SPOTS LARGER THAN A QUARTER, THEN TACKED WITH EMULSIFIED ASPHALT. EMULSIFIED ASPHALT APPLIED AT A RATE HEAVY ENOUGH THAT THE ENTRE AREA APPEARS BLACK IN COLOR. THIS METHOD TO BE UTILIZED IN BOTH TEMPORARY AND PERMANENT CONDITIONS. APPLIED IN TWO APPLICATIONS. THE FIRST APPLICATION WILL CONSIST OF 1/3 OF THE MULCH AND 2/3 OF THE SEED AND THE SECOND APPLICATION WALL CONSIST OF 2/3 OF THE MULCH AND 1/3 OF THE SEED. THE MULCH WILL INCLUDE A TACKIFIER AND WALL BE APPLIED AT A RATE OF A MINIMUM OF 2,000 LBS PER ACRE OR THE MANUFACTURER'S RECOMMENDATION, WHICHEVER IS HIGHER. 6. UPON COMPLETION OF THE PROJECT, PRIOR TO LEAVING THE SITE, THE WATER MANAGEMENT BRANCH SHALL BE NOTIFIED TO INSPECT THE PROJECT. POC MR. JACK WILSON 0 910-396-2301, EXTENSION 224. UTILITY CONSTRUCTION NOTE OLD NORTH UTILITY SERVICES, INC. SHALL CONSTRUCT THE WATER AND SEWER UTILITY SERVICES TO WITHIN 5' OF BUILDING. SPECIFICATION NOTE SPECIFICATIONS AND STANDARDS NOT REFERENCED HEREIN MUST CONFORM TO THE MOST CURRENT VERSION OF OLD NORTH UTIUTY SERVICES. INC. STANDARDS AND SPECIFICATIONS. Approved 8tormWtalter Permit Documents Construction ill accordance with these documents Is required by the stormwater Permit. North Carolina rubs require that the stormwaler system designer Inspect during construction; certify conformity with the plans and specs; and certify compliance with the stormwater rules. (15A NCAC 2H .1008 (j) ) PermN#3-4W419060y Date EL?E /y_ by�� NC Division of Water Duality Sheet # C O• /0 Revision Date B •� I GENERAL NOTES SHEET NUMBER C0.10 EROSION CONTROL: GENERAL NOTES: GRADING: 01 -1 �I o No. i TOTAL AREA WITHIN SITE LIMITS = 1.14 AC. TOTAL AREA DISTURBED = 1.45 AC. UNLESS OTHERWISE INDICATED, ALL VEGETATIVE AND STRUCTURAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE NORTH CAROLINA EROSION AND SEDIMENT CONTROL HANDBOOK. THE CONTRACTOR SHALL INSTALL AND MAINTAIN THROUGHOUT THE PROJECT CONSTRUCTION ALL EROSION CONTROL MEASURES SHOWN WITHIN THESE PLANS IN ACCORDANCE WITH APPLICABLE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES (NCDENR) EROSION AND SEDIMENT CONTROL REGULATIONS. , ALL CONSTRUCTION WORK SHALL BE IN COMPLIANCE WITH REGULATIONS OF THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) STORM WATER GENERAL PERMIT. ALL EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO CLEARING AND/OR LAND DISTURBANCE. A COPY OF THE APPROVED EROSION AND SEDIMENT CONTROL PLAN AND PERMIT SHALL BE MAINTAINED ON THE SITE AT ALL TIMES. THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES TO MINIMIZE EROSION. THE CONTRACTOR SHALL MAINTAIN CLOSE CONTACT WITH THE NCDENR EROSION CONTROL INSPECTOR SO THAT PERIODIC INSPECTIONS CAN BE PERFORMED AT APPROPRIATE STAGES OF CONSTRUCTION. APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS. CONTACT PROJECT ENGINEER AND PROJECT EROSION CONTROL INSPECTOR TO ENSURE ADDITIONAL EROSION CONTROL MEASURES ARE INSTALLED PRIOR TO OFF -SITE GRADING. PRIOR TO COMMENCING LAND DISTURBING ACTIVITIES IN AREAS OTHER THAN INDICATED ON THESE PLANS (INCLUDING, BUT NOT LIMITED TO OFF -SITE BORROW OR WASTE AREAS, STAGING OR STORAGE AREAS), THE CONTRACTOR SHALL PREPARE AND SUBMIT A SUPPLEMENTARY EROSION CONTROL PLAN TO THE OWNER FOR REVIEW AND TO NCDENR REGIONAL OFFICE FOR APPROVAL. CONTRACTOR SHALL PAY ALL FEES REQUIRED AND SHALL INSTALL NECESSARY MEASURES AT NO SEPARATE PAYMENT. THE CONTRACTOR SHALL PROVIDE THE OWNER AND THE ENGINEER A COPY OF THE AMENDED PERMIT. EROSION AND SEDIMENT CONTROL MEASURES SHALL BE MAINTAINED CONTINUOUSLY, RELOCATED WHEN AND AS NECESSARY, AND SHALL BE CHECKED AFTER EVERY RAINFALL. SEEDED AREAS SHALL BE CHECKED REGULARLY AND SHALL BE WATERED, FERTILIZED, RESEEDED AND MULCHED AS NECESSARY TO OBTAIN A DENSE STAND OF GRASS. STABILIZATION IS THE BEST FORM OF EROSION CONTROL. ALL DISTURBED AREAS WHICH ARE NOT OTHERWISE STABILIZED SHALL BE TOP SOILED AND SEEDED, TEMPORARILY OR PERMANENTLY IN ACCORDANCE WITH THE NORTH CAROLINA SEDIMENT CONTROL REGULATIONS. PERMANENT SEEDING AND GRASS ESTABLISHMENT IS REQUIRED PRIOR TO PROJECT COMPLETION AND ACCEPTANCE. CONTRACTOR TO ENSURE THAT SEDIMENT LADEN RUNOFF DOES NOT LEAVE SITE LIMITS OR ENTER PROTECTED AREAS. ANY SEDIMENT DEPOSITED BEYOND DISTURBED AREA WITHIN SITE LIMITS SHALL BE REMOVED. THE CONTRACTOR SHALL PROVIDE GROUND COVER ON DESIGNATED AREAS AND SLOPES GREATER THAN 3:1 WITHIN 7 DAYS FOLLOWING COMPLETION OF ANY PHASE OF GRADING. CONTRACTOR SHALL PROVIDE GROUND COVER IN 14 DAYS ON ALL OTHER AREAS FOLLOWING COMPLETION OF ANY PHASE OF GRADING. PERMANENT GROUND COVER FOR ALL DISTURBED AREAS SHALL BE PROVIDED WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION. ROLLED EROSION CONTROL PRODUCTS (RECP'S) SHOULD BE USED TO AID PERMANENT VEGETATED STABILIZATION OF SLOPES 2:1 OR GREATER AND WITH MORE THAN 10' OF VERTICAL RELIEF. RECP'S SHOULD ALSO BE USED WHEN MULCH CANNOT BE ADEQUATELY TACKED AND WHERE IMMEDIATE GROUND COVER IS REQUIRED TO PREVENT EROSION DAMAGE. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 21 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED. TRAPPED SEDIMENT AND THE DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. WHERE SEDIMENT IS TRANSPORTED ONTO A PAVED OR PUBLIC ROAD SURFACE, THE ROAD SURFACE SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. WHEN A CRUSHED STONE CONSTRUCTION ENTRANCE HAS BEEN COVERED WITH SOIL OR HAS BEEN PUSHED INTO THE SOIL BY CONSTRUCTION TRAFFIC, IT SHALL BE REPLACED WITH A DEPTH OF STONE EQUAL TO THAT OF THE ORIGINAL APPLICATION. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE SHALL BE REQUIRED AT ALL CONSTRUCTION STAGING AREA ENTRANCES AND ALL CONSTRUCTION ACCESS LOCATIONS INTO NON -PAVED AREA. TWO TO THREE INCH STONE SHALL BE USED FOR THE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE. ALL DRAINAGE INLETS SHALL BE PROTECTED FROM SILTATION. INEFFECTIVE PROTECTION DEVICES SHALL BE IMMEDIATELY REPLACED AND THE INLET CLEANED. FLUSHING IS NOT AN ACCEPTABLE METHOD OF CLEANING. DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. SEDIMENT BASINS AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND -DISTURBING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UPSLOPE LAND DISTURBANCE TAKES PLACE. ALL DISTURBED AREAS ARE TO DRAIN TO APPROVED SEDIMENT CONTROL MEASURES AT ALL TIMES DURING LAND DISTURBING ACTIVITIES AND DURING SITE DEVELOPMENT UNTIL FINAL STABILIZATION IS ACHIEVED. DURING DEWATERING OPERATIONS, WATER SHALL BE PUMPED INTO AN APPROVED FILTERING DEVICE PRIOR TO DISCHARGE TO RECEIVING OUTLET. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES PERIODICALLY AND AFTER EACH RUNOFF -PRODUCING EVENT. ANY NECESSARY REPAIRS OR CLEANUP TO MAINTAIN THE EFFECTIVENESS OF THE EROSION CONTROL DEVICES SHALL BE MADE IMMEDIATELY. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED BY CONTRACTOR ONCE STABILIZATION OR A SUFFICIENT GROUND COVER HAS BEEN ESTABLISHED OR AS DIRECTED BY THE ENGINEER. NCDENR'S FINAL APPROVAL IS REQUIRED. STABILIZATION MEASURES SHALL BE APPLIED TO STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED DEPENDING UPON FIELD CONDITIONS LIMITS OF GRADING SHOWN ON THE PLAN ARE MAXIMUM LIMITS FOR EROSION CONTROL PURPOSES ONLY. SURVEYOR TO DETERMINE ACTUAL LIMIT. ANY GRADING BEYOND THE DENUDED LIMITS SHOWN ON THE PLAN IS A VIOLATION OF THE NCDENR EROSION CONTROL ORDINANCE, AND IS SUBJECT TO A FINE. GRADING MORE THAN ONE ACRE WITHOUT AN APPROVED EROSION CONTROL PLAN IS A VIOLATION OF THE NCDENR EROSION CONTROL ORDINANCE AND IS SUBJECT TO A FINE. REVISIONS DATE I BY 1. ALL WORK SHALL CONFORM TO THE APPLICABLE CODES AND ORDINANCES. 2. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIM OR HERSELF WITH ALL CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS AS TO THE COST THEREOF. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIM OR HERSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 3. CONTRACTOR SHALL NOTIFY ENGINEER OF ALL PRODUCTS OR ITEMS NOTED AS "EXISTING" WHICH ARE NOT FOUND IN THE FIELD. 4. CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND OWNER'S REQUIREMENTS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND ERECTION OF ANY MATERIAL. ANY UNUSUAL CONDITIONS SHALL BE REPORTED TO THE ATTENTION OF ENGINEER. 6. CONTRACTOR SHALL CLEAN AND REMOVE DEBRIS AND SEDIMENT DEPOSITED ON PUBLIC STREETS, SIDEWALKS, ADJACENT AREAS, OR OTHER PUBLIC WAYS DUE TO CONSTRUCTION. 7. CONTRACTOR SHALL INCORPORATE PROVISIONS AS NECESSARY IN CONSTRUCTION TO PROTECT EXISTING STRUCTURES, PHYSICAL FEATURES, AND MAINTAIN SITE STABILITY DURING CONSTRUCTION. CONTRACTOR SHALL RESTORE ALL AREAS TO ORIGINAL CONDITION AND AS DIRECTED BY CONTRACT DRAWINGS. 8. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO START OF CONSTRUCTION. 9. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES (NCDENR). IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO POSSESS A COPY OF THE EROSION CONTROL PLAN AT ALL TIMES. 10. THE CONTRACTOR IS HEREBY CAUTIONED THAT ALL SITE FEATURES SHOWN HEREON ARE BASED ON FIELD OBSERVATIONS BY THE SURVEYOR AND BY INFORMATION PROVIDED BY OTHERS. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR SHALL CONTACT "NC ONE -CALL" AT 811 AND FT. BRAGG PWBC OFFICE AT LEAST 48 HOURS PRIOR TO COMMENCEMENT OF EXCAVATION OR DEMOLITION. 11. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH BASE TO OBTAIN AUTHORIZATION FROM THE POST PRIOR TO RELOCATION OF ANY EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. IF A UTILITY CONFLICT ARISES, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY ENGINEER, AND THE APPROPRIATE UTILITY COMPANY PRIOR TO PROCEEDING WITH ANY RELOCATION. 12. ALL PAVEMENT MARKINGS AND DIRECTIONAL SIGNAGE SHOWN ON THE PLAN SHALL CONFORM TO THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) STANDARDS. 13. ALL PAVEMENT JOINTS SHALL BE SAWCUT PRIOR TO PAVING TO PROVIDE A DURABLE AND UNIFORM JOINT. 14. REFER TO GEOTECHNICAL REPORT ENTITLED "REPORT OF SUBSURFACE INVESTIGATION" PROVIDED BY GEOTECHNOLOGIES, INC., DATED APRIL 15, 2014 FOR PAVING SUBGRADE INFORMATION. 14. NO HOLES, TRENCHES OR STRUCTURES SHALL BE LEFT OPEN OVERNIGHT IN ANY EXCAVATION ACCESSIBLE TO THE PUBLIC OR IN PUBLIC RIGHTS -OF -WAY. 15. IMMEDIATELY UPON COMPLETION OF CUTS/FILLS, THE CONTRACTOR SHALL STABILIZE DISTURBED AREAS IN ACCORDANCE WITH EROSION CONTROL NOTES AND AS SPECIFIED ON PLANS. 16. THE CONTRACTOR SHALL BE FULLY AND SOLELY RESPONSIBLE FOR THE REMOVAL, REPLACEMENT AND RECTIFICATION OF ALL DAMAGED AND DEFECTIVE MATERIAL AND WORKMANSHIP IN CONNECTION WITH THE CONTRACT WORK. THE CONTRACTOR SHALL REPLACE OR REPAIR ALL SUCH DAMAGED OR DEFECTIVE MATERIALS WHICH APPEAR WITHIN THE CONTRACT PERIOD. 17. ALL WORK PERFORMED BY THE CONTRACTOR AND/OR TRADE SUBCONTRACTOR SHALL CONFORM TO THE REQUIREMENTS OF LOCAL, STATE AND FEDERAL LAWS, AS WELL AS ANY OTHER GOVERNING REQUIREMENTS, WHETHER OR NOT SPECIFIED ON THE DRAWINGS. 18. WHERE THE TERMS "APPROVED EQUAL", "OTHER APPROVED", "EQUAL TO", "ACCEPTABLE", OR OTHER GENERAL QUALIFYING TERMS ARE USED IN THESE NOTES, IT SHALL BE UNDERSTOOD THAT REFERENCE IS MADE TO THE RULING AND JUDGMENT OF KIMLEY-HORN AND ASSOCIATES, INC. 19. THE GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION FOR THE WORK UNTIL TURNED OVER TO OWNER. 20. THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS ON SITE DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES. 21. THE CONTRACTOR SHALL TAKE FULL RESPONSIBILITY FOR ANY CHANGES AND DEVIATION OF APPROVED PLANS NOT AUTHORIZED BY THE ARCHITECT/ENGINEER AND/OR CLIENT/OWNER. 22. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. ANY MODIFICATION TO SUIT FIELD DIMENSION AND CONDITION SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO ANY WORK. 23. BEFORE THE FINAL ACCEPTANCE OF THE PROJECT, THE CONTRACTOR SHALL REMOVE ALL EQUIPMENT AND MATERIALS, REPAIR OR REPLACE PRIVATE OR PUBLIC PROPERTY WHICH MAY HAVE BEEN DAMAGED OR DESTROYED DURING CONSTRUCTION, CLEAN THE AREAS WITHIN AND ADJACENT TO THE PROJECT WHICH HAVE BEEN OBSTRUCTED BY HIS/HER OPERATIONS, AND LEAVE THE PROJECT AREA NEAT AND PRESENTABLE. 24. CONTRACTOR SHALL VERIFY EXISTING GROUND ELEVATIONS AT LOCATIONS OF ALL PROPOSED STORM DRAIN OUTLETS PRIOR TO CONSTRUCTION TO CONFIRM POSITIVE DRAINAGE AWAY FROM PIPE OUTLETS. CONTACT ENGINEER BEFORE CONSTRUCTION TO CONFIRM ANY ADJUSTMENTS TO PIPE LOCATION OR ELEVATION. GRADING NOTES 1. GRADE GRASSED AND LANDSCAPED SURFACES TO SLOPE AWAY FROM EXTERIOR OF PROPOSED BUILDINGS AT MINIMUM 5% FOR 10 FEET UNLESS OTHERWISE NOTED AND MINIMUM 2% BEYOND 10 FEET UNLESS OTHERWISE NOTED. 2. GRADE PAVED SURFACES TO SLOPE AWAY FROM EXTERIOR OF PROPOSED BUILDINGS AT MINIMUM 2% FOR 10 FEET. 3. SIDEWALK GRADES SHALL CONFORM TO THE FOLLOWING GUIDELINES: MINIMUM 0.5% AND MAXIMUM 8% PROFILE GRADE; AND 2% CROSS SLOPE. 4. GRADE DRAINAGE SWALES AND DITCHES AT MINIMUM 1% PROFILE GRADE UNLESS NOTED OTHERWISE. 5. CONTRACTOR SHALL NOTIFY ENGINEER IF SITE CONDITIONS OR OTHER FACTORS DISCOVERED DURING CONSTRUCTION WOULD PREVENT CONFORMANCE WITH THESE GUIDELINES. 6. RESTORE ALL DISTURBED AREAS NOT RECEIVING PAVEMENT OR OTHER SURFACE TREATMENTS WITH 4" TOPSOIL AND SEED. 7. FINE GRADING WILL BE AT THE DIRECTION OF THE LANDSCAPE ARCHITECT. B. SPOT ELEVATIONS AT CURB ARE MEASURED TO GUTTER FLOW LINE UNLESS OTHERWISE NOTED. Kimley)))Horn © 2014 KIMLEY-HORN AND ASSOCIATES, INC. 333 FAYETTEVILLE STREET, SUITE 600, RALEIGH, NC 27601 PHONE: 919-835-1494 FAX: 919-653-5847 WWW.KIMLEY-HORN.COM NC LICENSE #F-0102 KHA PROJECT 011737212 DATE 5/14/14 SCALE AS SHOWN DESIGNED BY PAB DRAWN BY DAW CHECKED BY PAB ALL WORK AND MATERIALS SHALL COMPLY WITH ALL FT. BRAGG REGULATIONS AND CODES AND O.S.H.A. STANDARDS. ALL CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES. ALL FILL TO BE COMPACTED PER THE RECOMMENDATIONS OF A GEOTECHNICAL ENGINEER. EXISTING AND PROPOSED GRADE CONTOUR INTERVALS ARE SHOWN AT 1 FOOT. THE CONTRACTOR SHALL IMMEDIATELY REPORT TO OWNER ANY DISCREPANCIES FOUND BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTION PRIOR TO PROCEEDING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING EXISTING UTILITIES, AND SHALL REPAIR ALL DAMAGE TO EXISTING UTILITIES THAT OCCUR DURING CONSTRUCTION. CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. LIMITS OF CLEARING SHOWN ON GRADING PLAN ARE BASED UPON THE APPROXIMATE CUT AND FILL SLOPE LIMITS, OR OTHER GRADING REQUIREMENTS. THE PROPOSED CONTOURS SHOWN IN DRIVES AND PARKING LOTS AND SIDEWALKS ARE FINISHED ELEVATIONS INCLUDING ASPHALT. REFER TO PAVEMENT CROSS SECTION DATA TO ESTABLISH CORRECT SUBBASE OR AGGREGATE BASE COURSE ELEVATIONS TO BE COMPLETED UNDER THIS CONTRACT. CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE SO THAT RUNOFF WILL DRAIN BY GRAVITY FLOW ACROSS NEW PAVEMENT AREAS TO NEW OR EXISTING DRAINAGE INLETS OR SHEET OVERLAND. TOPOGRAPHIC INFORMATION TAKEN FROM A TOPOGRAPHIC SURVEY BY CHANDLER LAND SURVEYING, PA. THE CONTRACTOR SHALL ADHERE TO ALL TERMS & CONDITIONS AS OUTLINED IN THE GENERAL N.P.D.E.S. PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES. ALL UNSURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 4 INCHES OF TOPSOIL. CONTRACTOR SHALL GRASS DISTURBED AREAS UNTIL A HEALTHY STAND OF GRASS IS OBTAINED. CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO SAME. THE CONTRACTOR SHALL INCLUDE IN THE CONTRACT PRICE ANY DEWATERING NECESSARY TO CONSTRUCT THE PROJECT AS SHOWN ON THE PLANS. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, BRACING AND SPECIAL EXCAVATION MEASURES REQUIRED TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OF THE WORK INDICATED ON THESE DRAWINGS. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE DESIGN(S) TO INSTALL SAID ITEMS. THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATION, ELEVATION, AND DIMENSIONS OF EXIT DOORS, RAMPS, BUILDING DIMENSIONS, AND EXACT BUILDING UTILITY ENTRANCE LOCATIONS. ALL FILL MATERIALS, EXISTING BUILDING FOUNDATIONS, PAVEMENT AND UTILITY STRUCTURES, TOPSOIL AND ANY OTHER DELETERIOUS MATERIALS SHALL BE COMPLETELY REMOVED FROM WITHIN THE BEARING ZONE BELOW THE STRUCTURE. ALL FOUNDATION EXCAVA11ON SHALL BE INSPECTED BY A QUALIFIED GEOTECHNICAL REPRESENTATIVE TO DETERMINE WHETHER UNSUITABLE MATERIAL MUST BE REMOVED. ALL UNDESIRABLE MATTER SHALL BE REMOVED, BACKFILLED AND COMPACTED AS REQUIRED BY THE GEOTECHNICAL REPRESENTATIVE. GRADES, ELEVATIONS AND LOCATIONS SHOWN ARE APPROXIMATE. AS DIRECTED BY THE ENGINEER, THEY MAY BE ADJUSTED TO ACCOMMODATE UNFORESEEN CONDITIONS. STATIONS, OFFSETS AND ELEVATIONS. REFER TO THE CENTER OF DROP INLETS, MANHOLES AND JUNCTION BOXES, AND THE MIDPOINT OF THE LIP FOR CATCH BASINS. ALL PIPES SHALL BE RCP CLASS III, UNLESS OTHERWISE NOTED. ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED. ALL AREAS WITH 2:1 SLOPE OR ERODABLE SLOPES SHALL BE COVERED WITH EXCELSIOR MATTING OR APPROVED EQUAL. INSTALL PER MANUFACTURER'S INSTRUCTIONS. CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND CONTINUOUS GRADE. CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. FT. BRAGG, NORTH CAROLINA PREPARED FOR FIRST CITIZENS BANK no Approved stormwater Permit Documents Construction in accordance with these documents is required by the stormwater permR. North Carolina rules require that the stormwater system designer Inspect during construction; certify conformity with the plans and specs; and certify compliance With the stormwater rules. (15A NCAC 2H .1008 Q ) ) Permit# 5w i4f0._Date 8• Zf ,5 by "'7 r� .yn_ . _ ✓4 NC Division of water Quallly Sheet # nyC _ZD--Revislon Date F•/f ' /u GENERAL NOTES SHEET NUMBER C0.20 a I ' •h / I�I v v o N o I x / E ioitly ' / o � / n I/ 0 a ° I I o I I `0 1 o rr y I n o I � \• 0 I t I rn v I 3 I V O I� N I J C I Is I I PAVEMENT RESTRIPING I ~ THISI AREA II I \ I \ I I I I I I I a I , ( I I I I/ /I fP / I \ I \�J j a - S6 d 00I P , d �' � B� � SIGN TO BE REMOVED / r \\\ - - 242 -- _ � / \`�A2. + i V 4------- %/ - i 1/ � 7 / cot, �a./L20.1g 8 -24"TRP-HWn \\` 241- _ _- CURB TO BE REMOVED \ (TYP.) 24}/ \ -240- ~STORM DRAIN -AND \ ; / P 777���yyy��� REMOVE INLET TOP,.AND J ! / REPLACE WITH MANHOLE LID. / \ II TREE PROTECTION FENCE \ UPSTREAM I (TYP.) 24" W STRUCTURE TO BE / { _ REMOVED \ \ TREE TO REMAIN (TYP.) �� B & 240{1 i " J \ - - --- -- \ I ` P EXISTING 12" I SOIL BORING (TYP.) r- _ -241 '- \ WATER LINE PER { \ - -242- - - - - -UTILITY LOCATOR { \ B 4 I o \ I , 20.2 t ) TREE TO BE REMOVED rn r { CLEARING LIMITS i x6"P �' + �q / (TYP.) SIGNS TO BE I` z L - { (TYP.)NS2028'1 \ 4 / { REMOVED __, ---�- m v - -_ �w�L cp _ram P r- Q"-r �J LEASE LIMITS (T)P.) i Nrp �I �12"WATER LINE �/N� \ SIGN TO REMAIN (TYP.) oa to Lr I + 242'- / a� v ' �A o� _- O q yy I °"W 373.97' 1 p 3,..... -'-' -0 r i 4- M = = ��� � � �._.....� M M �-SY'�� r• � �r'H -� W 4 s4 a �' ti - m- m a a m a i C a d--a a a f ¢ j z40� / o SIDEWALK (0 BE f70 39 4 � UFO REMOVED TYP. UFOP / -A - -- ----- -- �`------- - ---- _ h -err - --°-- t - .._F .. _- - _7 - -E-. - - ' ��-E--�- �X- -- f ,Z�}f,� � . � -ti Y�� �5 �' ••I t SgMH#2 ! -- -- ----p`DIP --- - -- - ;-.__-.- ss--- -. ---- s,,.-- ._ ss---�'- ss#- H §s-- ti, - - - _R•--. _ ' .?-_-C w. ..•'.... '.. •..: ry :•T�.;• a--s"E�- .1.t "" �`T.a.e+-.'� .k, 4'<.:r.+':. f: •� h.•'a�. .np-s'-�-T. •-•,-'jc. _ m �' • � ... �. ,- tit •`Y ... ._ - _.may....._ .. cJ. H i I PAVEMENT RESI THIS AREA MENT TO LOVED IN IIS AREA Ij STORM STRUCTURE TO BE REMOVED -JS4--I g7 I fis(RAPrr -r rrI-�4trn-rtrn-r r &1 / LEASE UMITS (TYP.) 1 / rCCURB TO BE ' OVED/REP 1 2-4t'' / CURB TO BE REMOVED i I 39\ / I [OUFOP ° 16 I / --- i - - - - - �240 i i I ?39_ CURB TO BE / s j 1 h > REMOVED l 1 -� I h - - EXISTING FIREN - - HYD �� '� // �� I REILLY ROAD -'_� -- ANT 238---- -- r- --2 N _..cam---.-.-r--.-^•_: ___._- -._ _. __- - _- ._ ......-. � ___. _. _.-.-.- _ T,-�,•iTr-`-T. _'_.^..^_ : i_-, _P \ . Wit'.' - �� -- 239 '-- - - - ..,..._-��r--�- _ - - b7--:;-s-.`e r4-• _�_,._,_.: a`"�°;v..�....�.•.�,,,. .,,,., ' .-.c, �a.-� - - = �'r` - - .,� - .�"�_'?".�"-' . �._..:.-..:_ -.:'4 _ _.._ ._. /� �•-- 1._� � - w--- - - - -. - yr� d -�- FY--- - .- - - •YYF���-._ 6 Cam. - - - - -,ry- _._. - - - - ry_ _._.. - e..-. - �{:--.._... - .- - .-... `rY-- �- - .2 ye_ _ .- �- � 1` TT-_. - � � n� ° SSMH#3 INV=229.02' FH-TBM r 'BOLT OVER 6 FLANGE" \ ELEV=240,71' - STORM DRAIN INVERTS - - SEWER DRAIN INVERTS - SDMH,41 SSMHdtl RIM= 242.01' RIM= 238.98' INV IN(NW)= 238.21' INV IN(NW)= 231.98' INV OUT(SE)= 237.91' INV OUT( W)= 231.78' SOMH,ff2 SSMH12 RIM= 241.99' RIM= 239.70' INV IN(NW = 238.49' INV IN(NE)= 230.20' INV OUT( E)= 238.49' INV OUT(SE)= 230.00' SDMHIfr3 SSMH f3 RIM= 242.51' RIM= 236.99' INV OUT(SE)= 238.81' INV IN(NE)= 224.99' INV OUT(NE)= 224.99' DI#!1 TOP= 241.27' INV OUT(SW)= 239.37' - SIGN LEGEND - S1 ONE WAY DIA2 S2 NO RIGHT TURN TOP= 241.15' S3 DO NOT ENTER INV IN(15"RCP)= 236.75' S4 NO PARKING INV IN(Sw)= 236.55' S5 EXCHANGE INV OUT( 4"RCP)= 236.45 S6 STOP S7 YIELD TOP= 241.54' TOP INV OUT(NE)= 239.44' - LEGEND - ® CONCRETE DI¢4 T6OP= 239,21' ® BRICK INV IN(SW))= 235.61' SOMH STORM DRAIN MANHOLE INV OUT(SE)= 235.21' SSMH SANITARY SEWER MANHOLE RCP REINFORCED CONCRETE PIPE D115 YI YARD INLET TOP= 238.78' DI DRAIN INLET INV IN(NW)= 234.68: HW HARDWOOD INV IN(SK9= 234.78 7RPL TRIPLE INV 0 T( E)= 234.58' P PINE TREE UFOP UNDERGROUND FIBER OP77C POST YI#I TOP= 240.85' DIP DUCTILE IRON PIPE INV IN NW = 238.25' 7MH TELEPHONE MANHOLE INV IN((SWj= 238.35' TSMH TRAFFIC SIGNAL MANHOLE INV OUT(NE)= 237.75' EMH ELECTRIC MANHOLE FH FIRE HYDRANT 7BM TEMPORARY BENCHMARK © FIBER OP71C BOX Rf U71UTY POLE ❑r TELEPHONE PEDESTAL ® TRAFFIC SIGNAL BOX U71LITY POLE W17H LIGHT WATER VALVE m GUY WIRE DEMOLITION LEGEND CURB TO BE REMOVED CURB TO BE REMOVED/REPLACED UTILITY TO BE REMOVED SIDEWALK TO BE REMOVED PAVEMENT TO BE REMOVED TREE TO BE REMOVED DISTURBED AREA: 1.40 AC SURVEY NOTE: 1. PER FEMA MAP 372005000J PANEL 0500 WITH AN EFFECTIVE DATE OF 010507, THE SITE IS LOCATED IN ZONE X. 2. GRID COORDINATES BASED ON NC GRID NAD83. 3. ALL EXISTING TOPOGRAPHICAL INFORMATION SHOWN WITHIN THIS DOCUMENT IS BASED ON A SURVEY PROVIDED BY CHANDLER LAND SURVEYING, PA., 309 SOUTH FUQUAY AVENUE, FUQUAY-VARINA, NC 27526 PROVIDED ON 2/20/2013. CURVE RADIUS LENGTH BEARING CHORD C2 160.50 40.88 S77°09'29"E 40.76 65 30.00 9.97 S11°011'24'W 9.92 C6 19.50 5.40 N77-00-41-W 5.38 LEASE LIMIT AREA: 1.14 AC IMPERVIOUS AREA: 0.34 AC PERVIOUS AREA: 0.80 AC Approved Storm water Permit Docum ents Construction in accordance with these documents is required by the stormwater permit. North Carolina rules require that the stormwater system designer Inspect during construction, certify conformity with the plans and specs; and certify compliance with the stormwater rules. (15A NCAC 2H .1008 (j) ) Permit #,�tJGl4G$D!f Date 8�u• by � NC Division of Water Quality Sheet # /• OD Revision Date 8 '76 '7f1 GRAPHIC SCALE IN FEET Lm1 0 40 KHA PROJECT 011 • 737212 v �,,, SHEET NUMBER au„DATE FT. BRAGG, NORTH5 REVISED PER 12" WATERMAIN LOCATLON 8/18/14 DAWKIMIveity,* Horn 5/14/14 - °E = EXISTING CONDITIONS AND © 2014 KIMLEY-HORN AND ASSOCIATES, INC. SCALE AS SHOWN CAROLINA = 333 FAYETTEVILLE STREET, SUITE 600, RALEIGH, NC 27601 DESIGNED BY PAB PREPARED FOR ', �''FNg{N�F`� hoc DEMOLITION PLAN C �� PHONE: 919-835-1494 FAX: 919-653-5847 DRAWN BY DAW FIRST CITIZENS BANK A WWW.KIMLEY-HORN.COM Hilltrtr� No. REVISIONS DATE BY NC LICENSE #F-0102 CHECKED BY PAB V f I o I I o � 0 Ed 0 OO $ MATCH EXISTING CURB 30J00' 1 o I.s. v a �o I ! 1 r �ryp� 00 16" CONCRETE PAVEMENT ro ( 18" CONCRETE 1 RESTRIPING ONLY ? A CURB AND GUTTER TYP. AREAS OUTSIDE o I CURB AND GUTTER No ( o PROPOSED LEASE o I OF LEASE LIMITS) LIMIT LINE (TYP.) ���\\\ I Op �� 18" CONCRETE I 5.00' p0 I I 1 CURB AND GUTTER N20.3T25E 159.24' a ( I 15Op I �SOp I R ! o o I R3 00 I I P 17S 00• RZOpp /�� E I 3�.00' Op O I 1• 100HHW n 4 D p 1 •' t4 60 O T L I I o N 4� SPILL CURB (TYP.) •O i 1 MATCH EXISTING p0 p O OO. o g• rn 0 FLAG POLES PAVEME T ALONG fOI z w ye� RS O• ku I it o I EXISTING DRI AISLES — AND VV a I AND PAR NG BAYS i / I 8.00' j n (TYP-) ALL HANDICAP PAVEMENTMARKINGS, SIGN AND 8.00, RAMPS TO MEETAGE LOCAL, m I "DO NOT ENTER" SIGN STATE AND FEDERAL ADA O REQUIREMENTS o AND "NO LEFT TURN" SIGN �y0 TEMPORARY 3 I 0 5' CONCRETE I CONSTRUCTION 24" STOP BAR (TYP.) SIDEWALK 6' CONCRETE TRAILER 0 1 MATCH EXISTING CURB a 0O $ID WALK 1 CLOSE OFF CR SS R5.00' a �� 96• O 1 ACCI SS MATCH EXISTING RSp� , a R150.00' 1 CURB a� '. .. . , .. c.. .. � ' , .. o D1#3 1 2 4.00' 4.00' YI CS —----------:!m- — -- -9: 9.50' 6.64' pS— — — �0'SZ9-� Tb 7tir — CP \ : 4 e, � I 4'x6' CONCRETE 4 •ql } PAD WITH BIKE 00 1 m dS3 RACK o Rg0.00 a "STOP" SIGN v 1 i o E`yppp?SO STORMWATER \\\\a I �:; =;. i ATM o $ 1 S7 O• BASIN CANOPY 30'HW 20.00' 1 I "7RP-HW F-F \ i • " — - ' ^mac J m . PROPOSED I i \ FIRST CITIZENS BANK I PROPOSED LEASE CURB FLUMEt 4, 610RY SF I .I 18" CONCRETE o 1 LIMIT LINE (TYP.) CURB AND GUTTER DI / ti� 2569 REILLY ROAD o SDMH#3 I �yp� / // BLDG 4-1673 I \ ���\�pyT y +` R40.0m °a //p l� 0� 36.03' v /pQ ( o eMATCH V I �i-- �,-- i_�® ' ' o PAVEMENT I SONG s // �V' pp — —� d jy `= F____ / / /\ 5'x5''• y ... c. EXISTING DRI AISLES a N Q� o o �� + CONCRETE p' AND PARKIN? BAYS DMH2 I 20.00' 22"HW n I__U \ o I c d u. o!� t. - PAD y=_tt Z 5' CONCRETE 1 SIDEWALK FCB SIGN 12'WATER LINE 5' CONCRET Iq \ SIDEWALK III PROPOSED LEASE i g I I I IM1 SPILL CURB (TYP.) LIMIT LINE (TYP.) a I I II I S20`2613"VV 373.97' I 1 I M rvim I w I= I I S4 11 TMI I a I C SDMHEI o�S ^° t I I < I TI ° FOP MAT3CH o' I I UFOP -_-_ 2� W D C F 238.67' 15"RCP L ro — — _ _ 1 s'RCP ' iRP H r= U EX CURB AND A --------- ---"------------_...---------------------------- D1#5 �� GUTTER 1 ``;+ --- —------------ c ��__� ❑O .-._- - --_�.- _ _ __g-__..-.--F_=0 E___-F__----E--_-__E E_-----E.__-_-_..-_� VF_-. ___-_ F v —3— YI 1 -- — E----I---E--- --E — c------E------E-------r------- 17 HW—c�---- S- 1 1 S (Y„HW ----- MATCH EXISTING i— ( -. O'tiW v I SSMH#'2 I g 8"D!P SIDEWALK « ----- --- — -- -- -----------s — n1H -- ----- — — — — — SS— — SS. --- S9\ C TSMH .. ..• .:e _.w. s.. 4v _ :l... u. ,'�:� d:.* 's: .w :.,••° f+r' S.•it :G••i.ii �cL'^' is. ?s:' •, \\ SS S SS S SS SS .,a F �.. o I I I STOP SIGN AND I 1 STOP BAR II CURB AND GUTTER BY OTHERS 10' TRANSITION I I w ACCESSIBLE RAMP (TYP.) - I ( DRIVE IMPROVEMENTS _ � I REILLY ROAD BY OTHERS GRAPHIC SCALE IN FEET i I II .N ..: • ,: • �__ _-_---__ _ _ .v:, � ., ,:. '',= �.:_'.._'_ •'.:+-�. •-:•+wr " • M +.+::i.:-i. W :: - _ .- --.-. r..^ "_..i:'f^�'_.r 'k!•i�•=n - `•'V--- - , w.:-..-. � - -__ . SSMH¢3 J� w "80 GE DRIVE IMPROVEMENTS \ _ PROPOSED TRAFFIC 2 SURVEY NOS: o BY OTHERS r, \ SIGNAL POLE BY \ OTHERS (TYP) ALL EXISTING TOPOGRAPHICAL INFORMATION i ` -:__ _ _- / SHOWN WITHIN THIS DOCUMENT IS BASED ON \ ' \ % AREA WITHIN PROPOSED LEASE LIMITS = 1.14 ACRES SURVEYING, PA. 309 SOUTH FUQUAY A SURVEY PROVIDED BY CHANDLER LAND PROPOSED SIGN AVENUE, FUQUAY-VARINA, NC 27526 \ 49,520 SQUARE FEET BY OTHERS PROVIDED ON 2/20/2013. 3- I c � i E I nstruction in accordance with these documents is A proved Stomtwater Permit Documents uired by the stormwater permit. North Carolina s rules require that the stormwater system designer a as is KHA PROJECT plans and specs; and certify compliance with the M 011737212 �� ttttttu tulq�� stormwater rules. (14 NCACd,6 (1Date- SHEET NUMBER 5 REVISED PER 12" WATERMAIN LOCATION 8/18/14 DAW DATE F T . B RAG G , NORTH ;\��`��\� CAR�Ii ��% by rJ+it# ��67 O Date i m e > o r n 5 /14/14 / #_� NC Division of Water Quality 4 REVISED PER FT. BRAGG COMMENTS - RAY BARBEAU (8/5/2014) 8/6/14 BJC CARD L I NA = = Sheet #�_�.�_2.0000 Revision Date / / SCALE AS SHOWN - SITE PLAN ^ 3 REVISED PER FT. BRAGG COMMENTS -RAY BARBEAU (7/1/2014) 7/7/14 BJC ©2014 KIMLEY-HORN AND ASSOCIATES, INC. : C'.00 DESIGNED BY PAB PREPARED FOR - N 2 REVISED PER DPW COMMENTS -LEE WARD (6/t2/t4) 6/t8/ta BJC 333 FAYETTEVILLE STREET, SUITE 600, RALEIGH, NC 27601 '�A�'; GINF 1 REVISED DRIVE-THRU WIDTHS PER OWNER REQUEST 6/4/14 DAW PHONE: 919-835-1494 FAX: 919-653-5847 DRAWN BY DAW FIRST CITIZENS BANK lhR WWW.KIMLEY-HORN.COM �rrnniutt" No. REVISIONS DATE BY NC LICENSE #F-0102 CHECKED BY PAB SITE LEGEND PROPOSED CONCRETE PAVEMENT MARKING DIRECTIONAL ARROWS PROPOSED HANDICAPPED PARKING PAVEMENT MARKINGS k SIGNAGE -0 NEW SIGN AS NOTED (M.U.T.C.D.) R20.00' FACE OF CURB RADIUS (TYP. ALL) --� F HANDICAP RAMP (DEPRESSED WALK) OPARKING SPACES s SPILL CURB LEASE LIMIT AREA: 1.14 AC IMPERVIOUS AREA: 0.49 AC PERVIOUS AREA: 0.64 AC 13 ?n3- i / l it (� 0 Ph 243.03 7 r25-r- D ti M WIN 243__ - J 2 52 Z42.89 0 • �-2 .42 242.61 '(J 242.45 t42.36 242.40 r Y.R3�� 1ST -.r-( 242.87 242.76 242.74 �242.60 .36 / - STORM DRAIN INVERTS - - SEWER DRAIN INVERTS - SDMHj1 SSMH#1 RIM= 242.01' RIM= 238.98' INV IN(NW))= 238.21' INV IN(NW))= 231.98' INV OUT(SE)= 237.91' INV OUT(SW)= 231.78' SDMH/12 SSMHJ/2 RIM= 241.99, RIM= 239.70' INV IN (NW = 238.49' INV IN NE = 230.20' INV OUT( E)= 238.49' INV O T( E)= 230.00' SDMH�r3 SSMH,j13 RIM= 242.51' RIM = 236.99, INV OUT(SE)= 238.81' INV IN(NE)= 224.99' INV OUT(NE)= 224.99' l Te TOP= 241.27' INV OUT(SW)= 239.37' - SIGN LEGEND - S1 ONE WAY DIP12 S2 NO RIGHT TURN TOP= 241.15' S3 DO NOT ENTER INV IN(15"RCP)= 236.75' S4 NO PARKING INV IN SW�= 36.55' S5 EXCHANGE INV OUT( 4"RCP)= 236.45' S6 STOP S7 YIELD D13 TOP= 241.54' INV OUT(NE)= 239.44' - LEGEND - CONCRETE DI#4 ICK ®H I INV IN (T(2)2 235.61' STORM DRAIN MANHOLE INV OUT(SE)= 235.21' SSMH SANITARY SEWER MANHOLE RCP REINFORCED CONCRETE PIPE DI#5 YI YARD INLET TOP= 238.78' DI DRAIN INLET INV IN(NW)= 234.68: HW HARDWOOD �-' INV IN(SW)= 234.78 TRPL TRIPLE INV OUT($SE)= 234.58' P PINE TREE UFOP UNDERGROUND FIBER OPTIC POST Y11P T6P= 240.85' DIP DUCTILE IRON PIPE INV IN(NW)= 238.25' TMH TELEPHONE MANHOLE INV INS - 238.35' TSMH TRAFFIC SIGNAL MANHOLE INV OUT(NE)= 237.75' EMH ELECTRIC MANHOLE FH FIRE HYDRANT IBM TEMPORARY BENCHMARK ❑F FIBER OPTIC BOX j .0' UTILITY POLE pT TELEPHONE PEDESTAL ® TRAFFIC SIGNAL BOX UTILITY POLE WITH LIGHT WATER VALVE I II m GUY WIRE LT L L'242.37 41.4-ze ' RIN:�241.79 PoM: 241 42 87 LF 242.10 INV a1: Be INV WT' 23832 1 INV OUT: 237.78 242 28 88 LF OF u o I 6gi I 3 41 LF OF RAA-. ais4 HP a RCP ZA2 241.79 d 9 O 242.60 15° RCP wv .-O-ASOX --242.47_ 1Z, 2c 242.57 242.7842 28 HP 241.83 242.$6 242 HP - - - o -- ----------- - - - CO 19 a II - N20s32'30°E . 8T- - - - \ �' � 242.50 2d7.8� • _ �. � • � o a I S4 242 241.62 \ 3 o. , - Nv: 23 240.30 ; \ d 'ao AS3 242.20 241 \\\ �" �. 9 6 y 242.12 0. n E / I HP Z� . " M r 6 LF OF 42 F OF ((11 i I 4° 7P4 L PVC y,, BIORETENTION 6 •p RIM: 2 I - a_. DI_ 243.00 BASIN h INy l 2 s6 a 42.03 242.50 \ t i i O Q10A \ > INV 7.4A ? o I / i aS7 2k i QO-12 x239.40 \ �' L..64 LF 241.92 INV 236k7 i \ \�S t (N' I N Ru:�zaz�o3 ROOF DRAIN 62 241,98 30"HW 242.20 \ \ I -e _ ___� I IN IN: 239.83 (RD-00-18) DOWNSPOUT ,\ "TRP-HW CURB FLUME WITH RIP RAP 241.86 11 _ \ INV IN: 239.83 (RD-co 15) (TYP•) 1 I ' HP INV. 236.97 �" -:RD- . > `.-` INV OUT' 239.83 • �' d I 1 n m j \ CHANNEL (TYPJ. MAINTAIN 7t LF of oa \ RIM: 2 / AT LEAST MINIMUM 241.66 4" PERF PVC \ MY IN: 2 .5T . 62 LF OF -g I DIMENSIONS INDICATED ON o 01o1r-� ' 1Nu-op _ 9'S; e ri DI PROPOSED ° SHEET C12.00 2 1.62 -�'. 242 3 FIRST CITIZENS BANK----- -. �I I "1=STORY � a , � 241.39 ,- 3 SDMh#.3 I 241.75 ' Ex. DI-4 4RE� $F zz LF OF RIM; 241.64 2569 ILLY OAD (I 241.31 241.51 ,S�RCP _ ---- WV IN: 235.61 (Ex DI-oz) BLDG 4-1677 I 241.57 LP o o.60x. 4pl + -- / �, INV IN: 236.22 (CS-10) x243.00 242.50 ' '/ CONVERT -24_3.0 INV OUT' 235.21 \6 DI "�- 7 ; ! _ 241.63 % EXISTI -01-TO" '-" - -� - 12" WATER LINE _241- -._ (-._ .26 MAN�IO�LGE. 1 � c242 89 D of o o.SQx PER UTILITY REPLACE TOP. wv z4au a osmr I m / IIJJ ` -- -_ _t _.- -'- 2qI .� -- - ! 243.00 -4 L R- ` 99 DMH2 S 22"HW \ ��44.1.48 2 1.86 242.50 0 241.65 J v P O - - - q !� RD : 0-17 242. z I ?y? - - i 243.02 - U RIM: 24247 I a - - .- I - r• .k �`., INV: 240.58 -w-HP -- Iw---- -�`^'�--- I' - --- -w1-- - ----Y+'--- 6 d i--------- - - Y i �'U `� WATER LINE LEASE LIMITS 3" CONDENSATETO r6D-OD 16 242.29 Z ( 0 MV TYP.) ROOF DRAIN SYSTEM. 240.44 a _ 242 , _1- = I I \ I I ® ON -ram �' tr` AN av ® ar �Ir.or ® a�rr ®�V o 13� ..a r ' ii- ®� ai ® a■ .__ -rafi� �raar• r. �• rs w e•rrro_. >• r w r I -- TMH - A - . _. D _ Q� a. v T a a Q �tL a -I 940-_a _ 5_TR -HW UFOP 1' d ' J I ° F hi UFOP {.' - _ _ - - -... -- - - I6 o1uF0 --- ���� o" 238.6T - 15"RCP L m A \ -I _- --_ -- -- �°� - - - - - - 18_RCP--- -- ------------------- -�------- Y^FA 5 Z _..- _ _. __ 24.i; ry� ° c (_'H--- ❑❑ -. '- .t -. -- ------ -Q- --E -----E -.---E � �----E- ----_. -----------E------E-- .. --E ---_ E - .�- - " v ITT_ Y? 1 ,.. - - _E- - - �.• :.- 10"HW E - j .. �3,_ E xi -a- _ - - E- - - T - -E- - - -e---mac-- - - M1 ,- / 17 -7 P-HW / S5 "H d- ' '` v -- c `F SS }I- •0 � .dl i- -- MH - my % T--'--- r "- SSMH 2 w TSMH .. .: . ...... ... ........ ..: �. a ... ..• > �: ,,•� z r.q. .• : :«. . h" . =r.'� � e: . wV' i• • �w• • S' • R-' ) - - - - ---- CL _ - - - - - - - - ------ - - - - - - - - - - - - i - - - - - - - - - - - - - - - - - - - -_"- - I REILLY ROAD t � a c a J � 0 a v o 0 ° t � Y a Y _ r Y o+ � o n E " U N a n ° 22 LF OF FLARED END SECTION WITH 8. DI - RIP RAP APRON (TYP.). 0 0.50% SEE SIZING SHEET C12.00 FES-13 LINV: 239.40 :110 RBA: 240-40 . -- _- -- INV IN: 236.90 (CO-14) 241.-INV Z36.�-(Cb-11) 78 241.56 HP INV O.242.20 ' UT: 236.33 v v ro M 1e a LEGEND • STORM MANHOLE (MH) OL LIMITS OF CONSTRUCTION 1PF TREE PROTECTION FENCE F01 CONTROL STRUCTURE (CS) PROPOSED CONTOURS EXISTING CONTOURS CM FLARED END SECTION (FES) CO 1 RIP -RAP • - ROOF DRAIN CLEANOUT x 10.58 PROPOSED SPOT ELEV. (HP) HIGH POINT STORM PIPE -8 (LP) LOW POINT SOIL BORING STORM DRAIN MANHOLE 241.78--� ��241.15 11241.27-, .n GRAPHIC SCALE IN FEET 0 10 20 40 Approved 3tormwater Permit Documents Construction in accordance with these documents is required by the stormwater permit. North Carolina rules require that the stormwater system designer Inspect during construction; certify conformity with the plans and specs; and certify compliance with the stormwater rules. (15A NCAC 2H .1008 (j) ) Permit#.SLt%G/ UBO Date 8 L6- /S/- by'29 .../a.?/ NC Division of Water Quality Sheet # e 4=. ao Revision Date i3 ( •Tu KHA PROJECT • 011737212 �""'/�/ SHEET NUMBER DATE im a >�� Qrn FT. BRAGG, NORTH n 5 REVISED PER 12" WATERMAIN LOCATION 8/18/14 DAW 5/14/14 SCALE AS SHOWN CAROLINA = = GRADING AND DRAINAGE PLAN 00 3 REVISED PER FT. BRAGG COMMENTS - RAY BARBEAU (7/2/2014) 7/7/14 BJC © 2014 KIMLEY-HORN AND ASSOCIATES, INC. C4 00 ' 2 REVISED PER DPW COMMENTS - LEE WARD (6/12/14) 6/18/14 BJC 333 FAYETTEVILLE STREET, SUITE 600, RALEIGH, NC 27601 DESIGNED BY PAB PREPARED FOR H F :� b o F 'gyp. 1 REVISED DRIVE-THRU WIDTHS PER OWNER REQUEST 6/4/14 OAW PHONE: 919-835-1494 FAX: 919-653-5847 DRAWN BY DAW CIN� �\\ FIRST CITIZENS BANK;rFR A••g�5' WWW.KIMLEY-HORN.COM o No. REVISIONS DATE BY NC LICENSE #F-0102 CHECKED BY PAB �i11��4 i U C N W ° U O N N a a a 0 _ T d E Y O 0 o' L 3 a a L N ° V O N N a a ° E 0 T d z T a 0 0 n ° a 0 3 D � Q o y� c Y ¢ N y - r ¢ Z 'o Q Y 1 3 J > E � o 0 — a n N � 5 i V a x� a v n v C d o° �a z 0 O O v n` N v I D d 0 V o Y V a n o 3 L J 3 �o > J laJ ¢ v Y N ° a Y � a w E v a n N h m s � o N T C 0 a a E a V y ]0 N N ¢ o Y v L N ¢ c z ° ¢ N Y ° N z v � L � v 1 C J v > W � a 6 o a N o X N J m O ° c O � J N c� o L ¢ 3 K m `y s 0 0 ° y E U v O Of D N v r 311101011111111111- I � I i I i I i I 4� PIPED BYPASS DRAINAGE AREA: 0.3624 AC IMPERVIOUS AREA: 0.2633 AC I_ ..._. PERVIOUS AREA: 0.0991 AC I i I co P Q BIORETENTION 1 DRAINAGE AREA: 0.4149 AC IMPERVIOUS AREA: 0.2863 AC \ PERVIOUS AREA: 0.1286 AC gyp, - �rpa ro ro ro ro ro ro N P n�6 ---SO .42 11111101110- 7 Ds td i I ! 17 � N - STORM DRAIN INVERTS - - SEWER DRAIN INVERTS - SDMH(Ft SSMH#I RIM= 242.))01' RIM= 238..98' INV IN(NWINV �237.91' 2878- OUT(SE) INV OU (SW) 231. SDMH#2 SSMH#2 RIM= 241.99' RIM= 239.70' INV IN(NW = 238.49' INV IN(NE = 230.20' INV OUT( E)= 238.49' INV OUT( E)= 230.00' SDMH 3 SSthi3 RIM 242.51' RIM = 236.99' INV OUT(SE)= 238.81' INV IN(NE)= 224.99' INV OUT(NE)= 224.99' TN TOP= 241.27' INV OUT(SW)= 239.37' - SIGN LEGEND - S1 ONE WAY DW S2 NO RIGHT TURN TOP= 241.15' S3 DO NOT ENTER INV IN(15"RCP)= 236.75' S4 NO PARKING INV IN(SW)= 236.55' S5 EXCHANGE INV OUT( 4"RCP)= 236.45' S6 STOP S7 YIELD DIA3 T = 241.54' INV OUT(NE)= 239.44' - LEGEND - CONCRETE I 0Ig4 TOP= 239.21' ® BRICK INV IN(SW))= 235.61' SDMH STORM DRAIN MANHOLE I INV OUT(SE)= 235.21' SSMH SANITARY SEWER MANHOLE RCP REINFORCED CONCRETE PIPE DI 5 W YARD INLET Te = 238.78' DI DRAIN INLET INV IN NW = 234.68: HW HARDWOOD / INV INS = 234.78 INV OUT( E)= 234.58 TRPL TRIPLE II P PINE TREE UFOP UNDERGROUND FIBER OP71C POST YI 1 TOP= 240.85' DIP DUCTILE IRON PIPE j INV IN NW - 238.25: TMH TELEPHONE MANHOLE INV IN(SYO= 238,35 TSMH TRAFFIC SIGNAL MANHOLE INV OUT(NE)= 237.75' EMH ELECTRIC MANHOLE FH FIRE HYDRANT TBM TEMPORARY BENCHMARK El FIBER OP77C BOX ,0' U71UTY POLE ❑r TELEPHONE PEDESTAL ® TRAFFIC SIGNAL BOX UTILITY POLE K17H LIGHT WATER VALVE m GUY WIRE I, ) I ' I ! 1 �I I' r ( a� `i ! 3� 2 \ \ \S'o I ._ -�,'1 .moo I N FIRST-CtA�ENS BANK ! I a \P \ / ' .� \ l "7RP--HW ? �� \ J i PROPOSED II y �' -111 i I f j I TO S gY 4 .261 SF Y / 2569 REILLY IR*D I �, FFE. 243.00 -- e I / i ry !/ MDM�H,�z o 2� .�� _ ?A —--- ; —-- `` �1 i — I i \ i — _ — — wATER. LINE I II^ 24SzV 2 ' \ - 41. \ I I S4 .� ® --® ®` s ■aP m r `� ® J ` �...___ -. -- --._ _ _ i errrPrr .. r mr.u.e...;a .. wo . r. o m — _. - 7MH , DMtTif� y I •. POI -A _ 25"TRP-HW °n UFOP �\ - UFOP,! TOTAL DRAINAGE -AREA: 14368 AC P _ _ I ,�� I [ltiFO L F 18"RC� — —— — — — — — — — -TOTAL--IIMPE-RVMS AREA-. 6 586Y_ = 238.67' 15"RCP CI° -- _— ---�E-=-- --- — -- #5 1 (SIAC�ERVIOT/S AREA: 0.8686 A — _---E-- ��} E --—T31E-0.76 GFS 10 -- —_. —3— _ _ _.. Y1 1 — — e— — — e— — — -•'—E -vc- - — — — — _ E-- — t''`C /� 17`NP-•HW S5 Cl "HW H d J v ' -TSMH 2 Q10: 1.93 CFS I p D!� i, SSMH1 y Ap" %� ----- SiS--- -- S------ qc----- SS--T — SS ----T; .----- yg------ _.- __ TSMH � 1 i LEGEND LIMITS OF CONSTRUCTION • STORM MANHOLE (MH) a TREE PROTECTION FENCE CONTROL STRUCTURE (CS) 1PF PROPOSED CONTOURS EXISTING CONTOURS CM FLARED END SECTION (FES) . CO-1 ROOF DRAIN CLEANOUT RIP -RAP a x 10.58 PROPOSED SPOT ELEV. (HP) HIGH POINT STORM PIPE (LP) LOW POINT /l O� /'P 5. GRAPHIC SCALE IN FEET 0 10 20 40 Approved 3tormwater PermitlDocuments Construction in accordance with these documents is required by the stormwater permit. North Carolina rules require that the stormwater system designer Inspect during construction; certify conformity with the plans and specs; and certify compliance with the stormwater rules. (15A NCAC 2H .1008 (j) ) Pe-rm1it,�#-,,$lrlG/yO80y Date B LE-/V bye /�..6/i NC Division of Water Quality Sheet # y Z_ Revision Date / • / r KHA PROJECT Ln �� v SHEET NUMBER �� 011737212 �� AAtICAR,� �: ' HDATE FT. BRAGG, NORTH m 5 REVISED PER 12" WATERMAIN LOCATION 8/18/14 DAW KaiI�1 (ely, orCI 5 14 14 POST DEVELOPMENT D RA I N AG E c SCALE AS SHOWN CAROLINA J ©2014 KIMLEY-HORN AND ASSOCIATES, INC. = 5 _ �� 2 REVISED PER DPW COMMENTS -LEE WARD (6/12/14) 6/18/14 81c 333 FAYETTEVILLE STREET, SUITE 600, RALEIGH, NC 27601 DESIGNED 6Y PAB PREPARED FOR a' FH E` O AREA q •,�J .,GINF...Z. PHONE: 919-835-1494 FAX: 919-653-5847 DRAWN BY DAW oR A 1 REVISED DRIVE-THRU WIDTHS PER OWNER REQUEST 6/4/14 DAW FIRST CITIZENS BANK ��' /rUllilttt IJ o No. REVISIONS DATE BY WWW-KIMLEY-HORN.COM NC LICENSE #F-0102 CHECKED BY PAB i