Loading...
HomeMy WebLinkAboutSW6140201_APPROVED PLANS_20140214STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS . :PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT APPROVED PLANS (❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD B180111111111111IMedical Applications of North Carolina, Inc. d/b/a FMC Anderson Creek Harnett County, North Carolina SITE DATA SHEET' INDEX OWNER: HM'S KIDS, INC. DUSTIN BLACKWELL 3035 NC 87 SOUTH CAMERON, NC 29326 PHONE: 919-6064M ENGINEER: CHANDLER ENGINEERING PA JIM CHANDLER, PE 309 S. FUQUAY AVENUE FUQUAY-VARINA, NC 27526 PHONE: 919-552-4845 FAX: 919-552-6962 EMAIL: liicremgfiveringpa com DEVELOPER: DAVID E. LOOPER & COMPANY, INC. CLARK ROWE PO BOX 3224, 32015TH STREET, SE HICKORY, NC 28602 PHONE: 828-324-1284 PROPERTY LOCATION. H.M. CAGLE DRIVE PARCEL NUMBER 9585-704666.000 REFERENCE: MAP 2-202 S 87 P c Q' �h� 5 o pout Springs 2a 87 � STTE cw a za e� cr 9 VICINITY MAP - 1"=1000' C1.01- EXISTING CONDITIONS AND DEMOLITION PLAN C2.01 - SITE STAKING PLAN C3.01- SITE GRADING PLAN C4.01 - SEDIMENTATION AND EROSION CONTROL PLAN C 5.01 - SITE UTILITY PLAN C5.02 - SANITARY SEWER PLAN/PROFILE C6.01 - SITE PLANTING PLAN C7.01 - SITE DETAILS C7.02 - EROSION DETAILS C7.03 - EROSION & STORM DETAILS C7.04 - UT [ ITY NOTES C7.05 - SEWER DETAILS C7.06 - WATER DETAILS PROPOSED USE: COMMERCIAL (DIALYSIS CLINIC) EXISTING TRACT AREA: 10.75 ACRES (TOTAL) chandler engineering ��'1„rCi4gr/�� pa ,,.��� Rod''• ZONING COMM 309 S. Fuquay Avenue, Fuquay-Varina, NC 27526 QQ`� 1r -+ COUNTY: HARNETT Phone: 919-552-4845 Fax: 919-552-6962 = D SEAL c TOWNSHIP: BARBEQUE 026UWW CALL 48 HOURS BEFORE YOU DIG 1-800 632-4949 NORTH CAROLINA ONE -CALL CENTER ky GENERAL NOTES PIN/ H58 KIDS INC 95-6 S, INC .000 MAP i 2-202 ZONING. COMM � 1. ALL UTILITIES OR STRUCTURES NOT INDICATED FOR REMOVAL OR T MODIFICATION ARE TO REMAIN AND BE PROTECTED FROM DAMAGE. 2. ALL WASTE MATERIAL GENERATED FROM CLEARING AND DEMOLITION ACTIVITIES SHALL BE DISPOSED OF OFF -SITE IN ACCORDANCE WITH WITH ALL APPLICABLE RULES AND REGULATIONS_v - 3. REMOVE TOPSOIL AND STOCKPILE APPROPRIAETLY ON -SITE. ON -SITE TEMP. STOCKPILES SHALL LOCATED WITHIN CONSTRUCTION LIMITS. \ SPOUT SPRINGS CHURCH INC. 4. ALL PAVEMENT OR CONCRETE TO BE REMOVED SHALL BE SAW CUT \\ \� PINT 9585-71-93]]000 TO PROVIDE A STRAIGHT AND UNIFORM JOINT WITH NEW \ r— \ D8 2371, PG 820 CONSTRUCTION. ANY EXISTING PAVEMENT, SIDEWALK, CURB & GUTTER, \V v I A\ MAP/ 2010-116 ZONING: COMM ETC. THAT MUST BE REMOVED TO ALLOW NEW CONSTRUCTION SHALL BE REMOVED AND REPAIRED PER THE SPECIFICATIONS AND DETAILS OR TO MATCH EXISTING CONDITIONS (WHETHER OR NOT SHOWN ON r \ V A \\\ \\\ THE DRAWINGS TO BE REMOVED). UTILITY INSTALLATIONS MAY UTILIZE OPEN CUT OF PAVEMENTS UNLESS INDICATED OTHERWISE. TRENCH \\ \\ EXISTING ASPHALT SHALL BE PATCHED PER PAVEMENT REPAIR COMBINATIOSILT/TREE DETAIL. / "'�\ ice\ \ \ \\ \ \ PROTECTION FENCING (TYP) D� ��"�� \ \ 5. PROTECT ALL ADJACENT PROPERTIES, THE GENERAL PUBLIC ANDA� / \\ \\ \\V A \\ \V A\ \\\ ALL OF THE OWNER'S FACILITIES. SHOULD DAMAGES OCCUR, NOTIFY" ARCHITECT IMMEDIATELY. \ \ \ \ \\ \\ \\ \\ 6. THE CONTRACTOR SHALL EMPLOY A QUALIFIED UTILITY LOCATOR SERVICE TO LOCATE ALL UNDERGROUND UTILITIES (INCLUDING BUT NOT LIMITED TO ELECTRICAL, TELEPHONE, GAS, CABLE, FIBER OPTIC) WITHIN THE LIMITS OF CONSTRUCTION.v 7. VERIFY ALL ILLUSTRATED KNOWN UNDERGROUND ELEMENTS. EXERCISE REASONABLE EFFORTS TO PROTECT ANY UNKNOWN UNDERGROUND ELEMENTS. NOTIFY THE ARCHITECT IMMEDIATELY IF UNKNOWN ELEMENTS ARE DISCOVERED THAT WOULD NECESSITATE MODIFICATION TO THE PROPOSED DESIGN. 8. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND OSHA REGULATIONS. 9. EXISTING MANHOLES, VALVE BOXES, VAULTS, CLEANOUTS, UTILITY POLES ETC. TO REMAIN WITHIN THE GRADING LIMITS SHALL BE ADJUSTED AS NEEDED TO FUNCTION PROPERTY WITH THE PROPOSED FINISHED GRADES (WHETHER OR NOT INDICATED TO BE MODIFIED)_ 10. GENERAL CONTRACTOR TO COORDINATE ALL PEDESTRIAN ACCESS PATHS, LOCATIONS, LIGHTING ETC. W/OWNER. '\V / EXISTw�.�ICHr POLE TO BE NEW vR\v�vEv\LV vOC\vVAT� I EADA\\v0 A\MW1 IKOIvOIRA \ Av\IK v3AV6AW� Y, LOCATION A 2 v I\TV \ v H COORDINATEWORK WITH LOCAL POWER COMPA�Y (C\ � LEI I I ( IAI I RII II \ALIII1III LI 1II 1 I IIVIIEI I1 GIIIIII I E�Ii I I1 IIAI I I I T1 1 OIIII NI 1 1I 1 /I A1I itNo D STRIP ITOPN sI&I l IIiII II 2 TOCKPIL OISOAININ 90 FEET 0}STING THE( DISTUR/C ARIN LIMIT CURB AND BE CUT AND REMOVEv 360 HD DP 'PARCEL 66 12 CpMBdVATI N S#_T/T /I /Ejl /EAN958570-6,00� ' 71 �/ 2-202 I I 1 1 PROTECTIONFEN)CING (TYl IPIIIIII 1 I)-----__— 10n CRESMNACOMZONI — — — — — — — — — — — — — — � 365 � EI I l /1 I I I / ilI I I 1I I I / I lI i , --TAR ALL vEc� AnoN TOPSOI AND V A \ I I I I I COM INATI N SI T/TREE I 1 I I I \ \\ I I I 1 1 \ V A V A \ \ STOCKPILE ON Si E WITHIN I A V A 1 A I F lDTE�770N ENCLI�JG (1jYP) I I I I I I I I \ V A V A \ \ ,. T F_�i. THE DISTURBED/CLEA�ING LIMI \I \ \\ \\ II 11 II I I 1 I I I I 11 II A I\ \\ II II II I I \ \ V A V A\ \V A E I O4ITiON L 1 G N 1 11 II vv vI vv � � I I I 3 ` I \ I I I I I I I \ \ I I / i HMS q05, INC \ OR 76ZPG.747 PARCEL ID. 039568 W94 04 _ PIN �V � CO BINATI SILT REE I O PROCTION �FENCIN(]�(TYP) I I I I I I I I I I O � API 2WO-74.000 MAP / \ \\\ 132000-Z4] AC ZONING. COMM \ I STRUCT. / UTILITY TO REMAIN TO BE REMOVED STRUCT / UTILITY TO REMAIN TO BE REMOVED ELECTRICAL _ - - --- -- E LIGHT POLE LI' # LP (OVERHEAD) - PPpp ELECTRICAL _ UTILITY POLE 'o' (UNDERGROUND) "- - --`-UE----- GNJ GW GUY WIRE � O FIRE PROTECTION -- - -----FP----- MANHOLE `v>Mhl OMH FORCE MAIN -_ --- -----FM----- c0 CO CLEAN OUT J O NATURAL GAS -- _ --- ---- G ---- DROP INLET OR BLS CE? SDI, CB SANITARY SEWER -- _ _ - ---- SS --- CATCH BASIN TELE / COMM. -- - ---- T ----- FIRE HYDRANT �} FH FH TELE. / COMM. -----UT----- WV WV (UNDERGROUND) WATER VALVE WATER -- -----W-- -- y�X, INDIVIDUAL TREE STORM DRAIN -__ _ _ _ _ _ `-c/ TELEPHONE PEDISTAL fT O TP UTILITY POLE - -0'PP EXISTING CONCRETE, ASPHALT OR - WP GRAVEL TO BE REMOVED WOOD POLE - D WATER WELL OWH SOIL BORING LOCATION SB-1 NOTE: DEMOLITION AND PATCHING OF PAVEMENT AND DISTURBED/CLEARING LIMITS SILT/TREE PROTECTION FENCE c OTHER EXISTING IMPROVEMENTS IN ADDITION TO THAT SEE DETAIL SHEET INDICATED ON THIS PLAN SHALL BE PERFORMED AS NECESSARY TO CONSTRUCT AND/OR INSTALL NEW WORK. I I I I II I I I II I I I I I I I I I I I i I III III III 1\\ I II I I VICINITY MAP (NOT TO SCALE) GRAPHIC SCALE 30 0 15 30 60 120 ( IN FEET ) 1 inch = 30 ft. 7. Laj l I'I', REVISIONS SEE TMSSHM / If L/OMBINAA TION IL E l I P40TEChON F NCING TYP) N pill R. CA i MAP III WO-Z4V I I h ZONINI COMMI \{ I I I I V/ / /�� � I I � I I I I � I 1 i I •� U cd 0 // // /// // // // // • V o 0 Cd CO08tNATION STET/TREE'") Q P� TECTION FElaCING (T/') /// j j /// //////// /• /// /// j / // / // // / W 4-4 " 0 / / / / / // / / / / • rl h�l tiIv-o RRvmWEDsr: JPc DATIL 1=14 PROIHCTNUU330: 1340 / COiID71Y HARNSIT Z Cohn& LOG110N: U8 HWY 678 TOWNWHP. BAaeBQus \ �` % % j / / // / / SITE EXISTING CONDITIONS AND DEMOLITION PLAN C1 O1 IANUARY 2014 PVC END CAP \ PVC TEE PVC ELBOW 1 WATER r- PVC END CAP PVC PIPE FLEXIBLE 112- HOLES IN HOSE UNDERSIDE END VIEW ARM ASSEMBLY SCHEDULE 40 PVC VENT PVC PIPE PIPE \ / SCHEDULE 40 PVC PIPE\ ORIFICE PLATE PVC TEE BOTTOM SURFACE FRONT VIEW _.C' ENCLOSURE PERSPECTIVE VIEW WATERUNENTRY IT SKIMMER DETAIL NOT TO SCALE TYPICAL POROUS BAFFLE PLACEMENT SUPPORT WIRE OR ROPE BASIN # SKIMMER ='RIFICE NUMBER DAM BOTTOM MINIMUM MINIMUM SPILLWAY SPILLWAY SIZE SIZE OF ELEVATION ELEVATION VOLUME SURFACE AREA ELEVATION WIDTH (IN) (IN) SKIMMERS (FT) (FT) (CF) (SF) (FT) (FT) 1 2 1. 5 1 339.00 335. 00 5,400 3,851 33& 00 15. 0 Pond Elevation Pond Area (ft) (W) 335,00 1,270,000 336.00 2,120.000 337,00 3,005,000 338.00 3,930.000 339.00 4,995r00D --------------PROPOSED TOP OF EMBANKMENT ELEV. 339.00----------- 100-YEAR WSE: 338.37' -------------EMERGENCY SPILLWAY ELEV. 338.00' 10-YEARWS_E: 337.96' ___ _ ____ - - - ---I-YEAR WSE_ 336_OS ---------------------- 11 1�__ =V: 335.00 4" CLEAN SAND MIN LBOTTOM WIDTH 1 � 8' MIN. SHWT ELEV. 327C) ------------------------------------------------------------ INFILTRATION BASIN SECTION NOT TO SCALE 16.4. Construction Care should be used during installation to minimize compaction of soil on the bottom and walls of infiltration devices since this will reduce the permeability at the soil interface. To avoid compacting the drainage media, light equipment and construction techniques that minimize compaction should be used. f Runoff shall not be directed into an infiltration device until the drainage area is stabilized. A construction sequence must be followed that reflects the need to stabilize the infiltration device. The longevity of infiltration devices is strongly influenced by the care taken during construction. Infiltration trenches should not be covered by an impermeable surface unless there is suitable maintenance access, the design specifies a H-20 loading capacity, and the application includes a cross-section of the H-20 design. Direct access must be provided to all infiltration devices for maintenance and rehabilitation. OSHA safety standards should be consulted for trench excavation. A minimum of one observation well shall be included in the design of an infiltration system to periodically verify that the drainage media is fully draining. The mmitoring well shall consist of a 4- to 6-inch-diameter, perforated polyvinyl chloride (PVC) pipe with a locking cap. The well should be placed near the center of the facility or in the general location of the lowest point within the facility, with the invert at the excavated bottom of the facility. - s 1A>f m t1Pnv'!!Jr Sr_n h Mode Summary Label F- ag Oz Q ITS Lu ww DOWNSTREAM SIDE w QO ma OO z CL STEEL POST 4' MAX. Rr=- VARIABLE AS DIRECTED BY THE ENGINEER Scenario Return Hyd"Vmrlh Time to Peak Peak Flow Evert Volume (min) RPM (vem) (ft3) Out -Pre t-year 1 443.000 805,750 0.01 Out -Pre to -)year 10 4,952.000 721.000 1.7S Out -pre t00-year too 14,079.000 716.000 5,72 Out -Pact 1-year t 0,000 0.000 0100 Out -Past 10-year 10 0.000 0.000 0.00 Out -Post 100-year 100 9,480,000 720.25D 10,73 Pond Summary Label Scenario ReWm Hydregroph Time to Peak Doak Mar Maximum Maximum Event Voktme (min) (tt3/5) waty Pond Storage (rears) (ft3} Sur�n (it3j (ft) Infiltration 1-year 1 5,SO6.000 716.0001 2.26 (NIA) (N/A) Basil (IN) Infiltration Basin (d0T) 1-year 1 1000 0.0o0 0.00 336.08 1,841.000 Infiltration 10-y®r 10 16,SDO.000 71S.S00 7.28 (NIA) (WA) Basin (IN) Infiltration Basin (OUT) 10-Mr 10 0.000 0,000 0.00 337.96 7,530.000 Infiltration 100-year 100 31,769,000 715.250 13.90 (NIA) (N/A) Basin (IN) Infiltration BdSln (O1JT} 100-year too 9,480.000 720.250 10.73 338.37 9,219,000 0 t PLYWOOD PAINTED WHITE 0 FT TYP. ANCHOR PLASTIC LINER WITH #57 STONE 10 MIL PLASTIC LINING IMPERMEABLE A SHEETING 3 F' 7 TYP 1 STANDARD BAFFLE NOT TO SCALE 48" CONCRETE WASHOUT 6-INCH BLACK LETTERS ANCHOR PLASTIC LINER WITH #57 STONE WIDTH: 2 FOOT MIN. � >� �I: I OR FLATTER SIDE SLOFE SECTION A -A PLAN EXCAVATED WASHOUT STRUCTURE CONSTRUCTION SPECIFICATIONS 1. LOCATE WASHOUT STRUCTURE A MINIMUM OF 50 FEET AWAY FROM OPEN CHANNELS, STORM DRAIN INLETS, SENSITIVE AREAS, WETLANDS, BUFFERS AND WATER COURSES AND AWAY FROM CONSTRUCTION TRAFFIC. 2. SIZE WASHOUT STRUCTURE FOR VOLUME NECESSARY TO CONTAIN WASH WATER AND SOLIDS AND MAINTAIN AT LEAST 4 INCHES OF FREEBOARD. TYPICAL DIMENSIONS ARE 10 FEET X 10 FEET X 3 FEET DEEP. MINIMUM CAPACITY IS 6 CF PER 10 CY OF CONCRETE. 3. PREPARE SOIL BASE FREE OF ROCKS OR OTHER DEBRIS THAT MAY GADS TEARS OR HOLES IN THE LINER. FOR LINER, USE 10 MIL OR THICKER UV RESISTANT, IMPERMEABLE SHEETING, FREE OF HOLES AND TEARS OR OTHER DEFECTS THAT COMPROMISE IMPERMEAB' ITY OF THE MATERIAL. 4, PROVIDE AND MOUNT A SIGN FOR THE WASHOUT WITHIN 30 FEET OF THE FACILITY 5, KEEP CONCRETE WASHOUT STRUCTURE WATER TIGHT. REPLACE IMPERMEABLE LINER IF DAMAGED (FIG., RIPPED OR PUNCTURED). EMPTY OR REPLACE WASHOUT STRUCTURE THAT IS 75 PERCENT FULL, AND DISPOSE OF ACCUMULATED MATERIAL PROPERLY. DO NOT REUSE PLASTIC LINER. WET -VACUUM STORED LIQUIDS THAT HAVE NOT EVAPORATED AND DISPOSE OF IN AN APPROVED MANNER. PRIOR TO FORECASTED RAINSTORMS, REMOVE LIQUIDS OR COVES STRUCTURE TO PREVENT OVERFLOWS. REMOVE HARDENED SOLIDS, WHOLE OR BROKEN UP, FOR DISPOSAL OR RECYCLING. MAINTAIN RUNOFF DIVERSION AROUND EXCAVATED WASHOUT STRUCTURE UNTIL STRUCTURE IS REMOVED. CONCRETE WASHOUT PIT DETAIL NOT TO SCALE GRADE - STEEL POST CONSTRUCTION SPECIFICATIONS 1. GRADE THE BASIN SO THAT THE BOTTOM IS LEVEL FRONT TO BACK AND SIDE TO SIDE. SUPPORT WIRE OR ROPE 2. INSTALL POSTS ACROSS THE WIDTH OF THE SEDIMENT TRAP/BASIN. -POROUS BAFFLE MATERIAL DRAPPED 3. STEEL POSTS SHOULD BE DRIVEN TO A DEPTH OF 24 INCHES, SPACED A MAXIMUM OF OVER SUPPORT WIRE H ROPE TOP OF FABRIC 6' HIGHER 4 FEET APART, AND INSTALLED UP THE SIDES OF THE BASIN AS WELL. THE TOP OF THAN INVERT OF SPILLWAY THE FABRIC SHOULD BE 6 INCHES HIGHER THAN THE INVERT OF THE SPILLWAY. TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERMS. ANCHOR BAFFLE IN TRENCH OR WITH 8" /-EROSION CONTROL MATTING STAPLES 4. INSTALL AT LEAST THREE ROWS OF BAFFLES BETWEEN THE INLET AND OUTLET DISCHARGE POINT. BASINS LESS THAN 20 FEET IN LENGTH MAY USE 2 BAFFLES. GRADE 5. WHEN USING POSTS, ADD A SUPPORT WIRE OR ROPE ACROSS THE TOP OF THE MEASURE TO PREVENT SAGGING. i 6. WRAP POROUS MATERIAL, LIKE JUTE BACKED BY COIR MATERIAL, OVER THE TOP WIRE, THE FABRIC SHOULD HAVE FIVE TO TEN PERCENT OPENINGS IN THE WEAVE. ATTACH SIDE VIEW FABRIC TO A ROPE AND A SUPPORT STRUCTURE WITH ZIP TIES, WIRE, OR STAPLES. 7. THE BOTTOM AND SIDES OF THE FABRIC SHOULD BE ANCHORED IN A TRENCH OR PINNED WITH 8-INCH EROSION CONTROL MATTING STAPLES. & DO NOT SPLICE THE FABRIC, BUT USE A CONTINUOUS PIECE ACROSS THE TRAP/BASIN. MAINTENANCE 1. INSPECT THE BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. 2. BE SURE TO MAINTAIN ACCESS TO THE BAFFLES. SHOULD THE FABRIC OF A BAFFLE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. 3. REMOVE SEDIMENT DEPOSITS WHEN IT REACHES 113 FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE BAFFLES. TAKE CARE TO AVOID DAMAGING THE BAFFLES DURING CLEANOUT SEDIMENT DEPTH SHOULD NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. 4. AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED, REMOVE ALL BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS, BRING THE AREA TO GRADE, AND STABILIZE IT. SEAL GE 026466 1 REVISIONS 1 GENERAL NOTES: Y 1. CLASS "'B" CONCRETE TO BE USED THROUGHOUT 3" i'-9" 1'-9" 3" 2. OPTIONAL CONSTRUCTION - MONOLITHIC POUR, X X 2" KEYWAY, OR #4 BAR DOWELS AT 12" CENTER, AS DIRECTED BY THE DESIGNER. (10)-3/8" DIA. 3. TWO 2" PIPE WEEP HOLES TO BE PLACED AS WELDED STUD DIRECTED BY ARCHITECT. `O ANCHORS 8" LG. 4. FORMS ARE TO BE USED FOR THE CONSTRUCTION w F Ej PIGCY" ANCHORS IF THE BOTTOM SLAB. z PIGGYBACK =8") 5. IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, ADO TO BASE AS SHOWN ON N.C.D.O.T. p STANDARD 840.00. Y HOLES E A STONE DRAIN CONSISTING OF i CUBIC FOOT OF 3 NO. 78M STONE CONTAINED IN A BAG OF POROUS o PLAN PLAN FABRIC SHALL BE PLACED AT EACH WEEP HOLE. H W/GRATE & FRAME REMOVED SHOWING POSITION OF BOLTS 7. ALL DROP INLETS OVER 3'-6" IN DEPTH TO BE w W w FRAME &GRATE PROVIDED WITH STEPS 1'-2" ON CENTERS. 5 5 3/8'"DIA.x 8"LG. STEPS SHALL BE IN ACCORDANCE WITH N.C.D.O.T. C) �840.1O.T. STANDARD o N.C.D. WELDED PIGGYBACK STANDARD 840.66. 4'-O' 3'-0'• STUD ANCHORS a < i 3,� 3., 3r. I-- �I 3,. v a Q N Err A 6" 6rr co-r Q N N '� _ CONSTRUCTION DOCUMENT N #4 BAR DIMENSIONS FOR CHANNELS TOTAL N0. SIZE LENGTH LIN. FL 2 3"x4.1rr 4'-D" 8'-0" io SEE NOTE #2 DOWEL 6 2 3"x4.1 " 2'-6" 5'-0" SECTION-XX SECTION-YY DOWEL . r..4 DIMENSIONS AND GJANPTIES FOR DROP INLET DIMENSIONS OF BOX & PIPE ::URIC YARDS TOTAL DEDUCTIONS O PIPE SPAN WIDTH HEIGHT IN BOX QUANTITIES FOR ONE PIPE BOX & CU. YDS. COVER D A B H FLOOR & WALL / CU. YDS. C.M. R.C. COPING FT H MIN. H rt 12" 3'-0" 2'-0" 2'-8" 0.262 0,222 0.855 0.015 0.024 �1 15" 3'-0" Y 0.929 0.023 0.036 O 18" 3'-5" 1.021 0.033 0.049 24" 4'-0" I L151 0.059 0.085 30" 3'-0" 2'-0" 4'-3" 0,262 0.222 1.207 0.092 O. 127 O (� 1'-7 5/8rr O -7 5/8 V / i is/32'" C i/8" 1/8" • O \/ r l O 3" 6'" i,r 1,r `J O D D S 3"-3 3 4" 1181r rl A A 3/4r. 3, 2" 3/4" N O N 0 co 1 15132" rn C 2 i/8- 3'-1 314" 2 1/8" i 5183' 6-+-) 1 s/8" " 3 ,r ^� 1'-4 1/2" 1'-4 112" C PLAN OF GRATING PLAf• OF FRAME SECTION -AA r..4 Q CAST IRON (AST IRON fit` 1/811 rT 4- 1 1/8r. 7/8„ 1 •_7 5/8•• 3/4" 314" N •� 1 7 5/8 � I x 3 1 /4 N N T 2 1 2 1/8" N REVIEWED BY: 1FC 1 1 3/16- DATE: 1/28/14 1" DEPRESSION 2" 2'-6" PROJECTNUMBER. 13-005 COUNTY HARNETT SECTION-DD SE--TION-CC SECTION -BB ZONING: Comm LOCATION: US HWY 87 S TOWNSHIP: BARBEQUE STANDARD CONCRETE DROP INLET NOl TO SCALE 314-/W1V Z,/ z8/24/4 EROSION & STORM DETAILS C7603 JANUARY 2014 GENERAL NOTES '/ HM"S KIDS, INC /S, / PINX MAP # 2-879a.000 MAP # 1-202 1. TOTAL DISTURBED AREA = 4.0 ACRES. 2. ALL EXISTING VAULTS, MANHOLES, STORM DRAIN STRUCTURES, VALVE BOXES, CLEANOUTS, ETC. SHALL BE ADJUSTED AS NEEDED TO MATCH FINISHED GRADES. 3. ALL BACKFILL, COMPACTION, SOILS TESTING, ETC. SHALL BE PERFORMED BY THE OWNER'S INDEPENDENT TESTING LABORATORY. 4. ALL SPOT ELEVATIONS INDICATED ARE AT BACK OF CURB, UNLESS OTHERWISE INDICATED. 5. SITE IS NOT WITHIN 100 YEAR FLOOD PLAIN. 6. ALL ELEVATIONS ARE BASED ON NC GRID NORTH (NAD 83). 7. A PRECONSTRUCTION MEETING MUST BE SCHEDULED PRIOR TO WORK, GRADING AND INSTALLATION OF EROSION CONTROL. B. UTILITY LOCATIONS ARE TO BE FOUND BY CALLING NC ONE CALL. 9. ALL HANDICAP PARKING SPACES AND STRIPED ACCESSIBILTY AISLES ARE TO HAVE NO MORE THAN A 1:50 SLOPE IN ALL DIRECTIONS. 10, ALL SIDEWALKS ARE TO HAVE NO MORE THAN A 1:20 SLOPE FOR THE LENGTH OF THE SIDEWALK AND NO MORE THAN A 1: 50 SLOPE FOR THE WIDTH OF THE SIDEWALK. 11, IF CONTRACTOR NOTICES ANY DISCREPANCIES IN ANY OF THESE SLOPE REQUIREMENTS, IT IS THE CONTRACTOR'S RESPONSIBILTY TO CONTACT THE OWNER PRIOR TO POURING ANY CONCRETE SO THAT A SOLUTION CAN BE FOUND, 12. SPOT ELEVATIONS ARE GIVEN AT A MAJORITY OF THE MAJOR BREAK POINTS, BUT IT SHOULD NOT BE ASSUMED THAT ALL NECESSARY SPOT ELEVATIONS ARE SHOWN. DUE TO SPACE LIMITATIONS, THERE MAY BE OTHER CRITICAL SPOTS NOT LABELED THAT SHOULD BE TAKEN INTO CONSIDERATION. THE CONTRACTOR SHALL REVIEW THE GRADING PLAN IN DETAIL AND SHALL ENSURE THAT ALL CRITICAL GRADE POINTS ARE STAKED AND FOLLOWED TO PROVIDE POSITIVE DRAINAGE. ZONING` COMM / 352 \� r 411 \ 351.41 1 w 354 \ h 3si r / SPOUT SPRINGS CHURCH INC. PIN# 9585-71-9377 WO DO 2311, PG 820 MAP# 2010-116 ZONING. COMM \ TEMPORARY GRADING EASEMENT \ 3 W.22 T 0 Cd LEGEND N � N EXISTING CONTOURS v � Z m E? PROPOSED CONTOURS e EXISTING STORM DRAIN PIPE m PROPOSED STORM DRAIN PIPE ��/)�j��/�� � _( tic 2 LL 'p SITE MORCgS,I, Li- DISTURBED/CLEARING LIMIT LINE �- d "VTQJ4 i�l Q u] ---------- DRAINAGE AREA LINE �!i` ryP� m - ,- a \\ 0000.00 T PROPOSED TOP OF CURB ELEVATIONCIS LL 0- \ 0000.00 P PROPOSED GROUND/PAVEMENT ELEVATION \\ P SEALS 0 BMP MAINTENANCE AND ACCESS EASEMENT OS2 T ORARY/GRADING EASEMENT 41, 355 35A10 r \ EXISTING CI / / 354.63 T / 35541 T TOP-356 02' 354.67 P �INv OUT=352.63 / .%s S �� 355..A 7 V / V i � v � � ,us.a r IT °/Ex�lapc r� V A\ ss4s / ssx49 r I 7 7v ,us.49 T e6 P 3S2 7 V/ / ///// TOINV IN( / IN, INV L OUT--352�1' - IMPERVIOUS AREA „ 354 EXISTING IMPERVIOUS AREA: 0.00 ACRES DIAIYSIS CENTER 3 PROPOSED IMPERVIOUS AREA: 1.01 ACRES (56.1% OF LEASE AREA) 353s3 / / 97 r 20 (� {� ow(��/j CE 4 i � i 9 i0lrt i i/r OI"€hh WAIoF C1UAL vTl 46z r / s Jypllacl,�f lL �,r !rA Elil�h so ��55 / � 35p �♦ I ..�'� � I` / � � I I /ii 355 I 47 /] p// l ice/ A PARCEL ID'03986830 9 12 94' _ PIN 9585-] -4666. 00 1. o 7,89 \ "PA� # 2-202 f07 AORES \\ ZONINs, 54 365 / - - s8 6N, TOP=36fl96' / - � � 1 I � I /� i =36,9Y INV OUT=362/%�/''✓�^i -vim A I� o INV IN=362 2 TOP �I / / 'r'r j I I �-IT HMS KIDS" INC A DR:. 03956: 797 l I I I I I I I I I I I I I PARCEL ID: 039568 0094 04 I I I PIN 9585-]0-0210.000 \ MAP # 2000-747 2D2NG: AC V I I l l I I i �► �' i i i I I I TC RM RAII�IA'G C�HARl' I I I \v I I I I � I I I I I I I *4� �l 41I I III I II II I MATCHLIN / / / l / �v .I i �� ■ SEE THIS SHEET MAJOR DRAINAGE STRUCTURE SCHEDULE (DESIGN) STRUCTURE NO. PIPE I SLOPE PIPE DIA. PIPE LENGTH PIPE MATRL UPPER W. LOWER INV. I UPSTREAM STRUCTURE DATA UP STRM DN STRM OP ELEV. DEPTH TYPE (IN) (FT) (FT) (FT) (FT) (FT) 1 2 1.49% 15 145 HDPE WITH SOIL TIGHT JOINTS 349.48 347.32 353.48 4.00 DI 2 3 1.08% 15 192 HDPE WITH SOIL TIGHT JOINTS 347.32 345.24 353.32 6.00 DI 3 4 16.00% 18 64 HDPE WITH SOIL TIGHT JOINTS 345.24 335.00 353.24 8.00 DI 5 3 3,54% 15 98 HDPE WITH SOIL TIGHT JOINTS 348.71 345.24 352.71 4.00 DI LEGEND NOTES N DI DROP INLET, SEE DETAIL SHEET TOP ELEV. OF DROP INLET (DI) IS TOP OF GRATF. O STRUCTURE IDENTIFICATION VICINITY MAP (NOT TO SCALE) GRAPHIC SCALE ( IN FEET ) 1 inch = 30 ft. MATCHLINE 120 REVISIONS SEE THISSHEETIT CONSTRUCTION DOCUMENT I I � U PIryXA9 85iI70-021 .000 II MAP ZONINt�:�COMM 74 V I I I I �j)CIS It4-4 4-4 CIS REVIEWED BY JFC DATE: I/28114 PROJECT NUMBER: 13-005 / / / / / / / / COUNTY HARNETT ZONEQG: COMM V/ / / / LOCATION: US HWY 87 S TOWNSHIP: BARBEQUE V/ SITE GRADING PLAN sw61¢0 Zo, C3,01 JANUARY 2014