HomeMy WebLinkAboutSW6110707_APPROVED PLANS_20110819STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW1(I�l(2Q DOC TYPE ❑ CURRENT PERMIT FOV Lr APPROVED PLANS (❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD �L W Q M a N m EROSION CONTROL NOTES: 1. THE CONTRACTOR SHALL INSTALL TEMPORARY EROSION CONTROL DEVICES AT EACH 5. PROVIDE SILT FENCE AND/OR OTHER DEVICES AS MAY BE REQUIRED TO CONTROL SOIL STORM WATER INLET IMMEDIATELY AFTER CONSTRUCTION. ALL OTHER EROSION EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, CONTROL DEVICES SHALL BE INSTALLED PRIOR TO COMMENCING CONSTRUCTION AND GRADED, AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY SHALL REMAIN IN PLACE UNTIL AN ACCEPTABLE GROUND COVER IS ESTABLISHED. THE INSTALLATION. FILL, COVER, AND TEMPORARY SEEDING AT THE END OF EACH DAY CONTRACTOR SHALL CLEAN ANY AND ALL SEDIMENT FROM NEWLY CONSTRUCTED ARE RECOMMENDED. IF WATER IS ENCOUNTERED WHILE TRENCHING, THE WATER STRUCTURES PRIOR TO COMPLETING WORK EACH DAY. SHOULD BE FILTERED TO REMOVE ANY SEDIMENTS BEFORE BEING PUMPED BACK INTO ANY WATERS OF THE STATE. 2. SLOPES, WHICH EXCEED EIGHT (8) VERTICAL FEET OR EXCEED 3:1 SLOPE SHALL BE STABILIZED WITH SYNTHETIC OR VEGETATIVE MATS, IN ADDITION TO HYDROSEEDING. ON 6. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES SLOPES LESS THAN 3:1 STRAW MULCH SHALL BE DISTRIBUTED OVER THE DISTURBED OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL AREA AFTER APPLICATION OF SEED. THE STRAW MULCH SHALL BE SPRAYED WITH A DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE BITUMASTIC SEALER FOR ANCORAGE. SWALE AND DITCH BOTTOMS SHALL BE DOUBLE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEEDED. HYDROSEED MAY BE SUBSTITUTED FOR SEEDING AND STRAW MULCH. IT MAY SEDIMENTATION. ALL TEMPORARY CONTROL DEVICES SHALL BE REMOVED ONCE BE NECESSARY TO INSTALL TEMPORARY SLOPE DRAINS DURING CONSTRUCTION. CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED. TEMPORARY BERMS MAY BE NEEDED UNTIL THE SLOPE IS BROUGHT TO GRADE. 7. THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD 3. STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONS ONTO PAVED ROADWAYS FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL FROM PAVEMENT AS MAY BE CEASED, BUT IN NO CASE MORE THAN FOURTEEN (14) DAYS AFTER WORK HAS CEASED REQUIRED. A TEMPORARY GRAVEL CONSTRUCTION EXIT SHALL BE ESTABLISHED AT ALL EXCEPT AS FOLLOWS: POINTS USED FOR CONSTRUCTION TRAFFIC EGRESS. WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN 8. TEMPORARY DIVERSION BERMS AND/OR DITCHES WILL BE PROVIDED AS NEEDED DURING GROUND CONDITIONS, STABILIZATION MEASURES MUST BE INITIATED AS SOON AS CONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND/OR TO DIVERT PRACTICABLE. SEDIMENT LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS. WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE HAS TEMPORARILY 9, ALL WATERS OF THE STATE (WOS), INCLUDING WETLANDS, ARE TO BE FLAGGED OR CEASED, AND EARTH -DISTURBING ACTIVITIES WALL BE RESUMED WITHIN 14 DAYS, OTHERWISE CLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SILT FENCE IS TO BE TEMPORARY STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THAT INSTALLED IN ALL AREAS WHERE A 50-FOOT BUFFER CANNOT BE MAINTAINED PORTION OF THE SITE. BETWEEN THE DISTURBED AREA AND ALL WOS. A 10-FOOT BUFFER SHOULD BE 4. ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED EVERY SEVEN (7) MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL WOS. DAYS. IF SITE INSPECTIONS IDENTIFY BMPS THAT ARE DAMAGED OR ARE NOT 10. LITTER, CONSTRUCTION DEBRIS, OILS, FUELS, AND BUILDING PRODUCTS WITH OPERATING EFFECTIVELY, MAINTENANCE MUST BE PERFORMED AS SOON AS PRACTICAL SIGNIFICANT POTENTIAL FOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED OR AS REASONABLY POSSIBLE AND BEFORE THE NEXT STORM EVENT WHENEVER PRACTICABLE. LUMBER AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORM WATER MUST BE PREVENTED FROM BECOMING A POLLUTANT SOURCE IN STORM WATER DISCHARGES. CONSTRUCTION SEQUENCE 1. INSTALL SILT FENCE 2. INSTALL TEMPORARY SEDIMENT TRAPS 3. INSTALL TEMP. DIVERSION BERM 4. INSTALL PERM. DETENTION POND IN CONCURRENCE WITH PARTIAL CLEARING OF SITE (ONLY CLEAR AREAS UPSTREAM OF DIVERSION BERM AND SED. TRAPS) 5. REMAINDER OF CLEARING AND GRUBBING 6. ROUGH GRADING 7. INSTALL UTILITIES AND STORM DRAINAGE 8, BUILDING CONSTRUCTION 9. FINE GRADING 10. PAVING 11. REMOVE TRAPPED SEDIMENT FROM DET. POND AND CONVERT FROM SED. BASIN TO SAND FILTER 12. PERMANENT SEEDING AND FINAL STABILIZATION OF SITE 13. REMOVE ALL TEMPORARY EROSION CONTROL W C_ r 0 z 0 CLEANOUT DRAINAGE AREA #1 ss� INV = 174.00 (12' ;�'�'�'py ..._.•. - .q t ',, 6 m 9ao'96a '• .e 0i of 0 CA 174.93 ,.r PROPOSED CANOPY. ROOF rn 's 174A 7 YARD DRUNK GR = 175.20 r, INV = 173.58 (8' 12"HDPE INV = 173.89 (12' NCO • �(� '" ... r 0 N PROPOSED OFFICE EXPANSION o F.F.E. = 176.60 a (IMPERVIOUS AREA = 0.226 AC.) Q (DRAINAGE AREA #1 = .534 AC.) 7' LO CLEANOUT INV = 173.82 (12' I!? O 00 x o CO m ' LO in J 3 I 00 ro ' MJ I � I U 0 0 c O ` o J ' 0 O CIO rn i' M ; o ' E L� DRAINAGE AREA /2 s� (IMPERVIOUS AREA = .647 AC.) 6' (DRAINAGE AREA #2 .903 AC., J PROPOSED BUILDING STORM MIT + F.F.E. = 176.60 If TOP=172.14Js INV. IN(1)=165.69 )N(2)=165.79 PROPOSED DOWNSPOUT 65.69 (TYp,) CLEANOUi INV = 173.93 (6' + STORM PIPE EX. BUILDING FIN. FLOOR. 176.60' +'s ++ 'ems s f 4J F 2 w \ (PROVIDE INLET PROTECTION) 9 DROP INLET sgs INV. IN-169.72 1 4.93 INV. OUT=169.72 4 's CLEANOUT s 's ''s ''s CLEANOUT DRAINAGE AREA 03 (IMPERVIOUS AREA = .552 AC.) (DRAINAGE AREA #3 = .830 AC.) �� 8J aJ s'JC PROPOSED BUILDING a j SAW -CUT SLOT AT INV. IA50 F.F.E. = 176.60 +1� ON NORTH -FACE OF EX. INMT 'g 's I (PROVIDE INLET PROTECTION) s DROP INLET C OUT TOP=174.81 INV. IN=170.44 INV = 17. 17i A r- INV. OUT=170.36 rV74 ,13 III 12"HDPE :9s C0 12"HDPE STORM PIPE ------- ------- _ STORM PIPE (6' I11 M + s �D POSEDI I '•.' .9 IDROP �i SSS60l,�i i S CLEANOIIT '0 INV = 173.93 (6' ' ' s INV = 173.18 12' s s s s s o CLEANOUTATCH PAVEMENT �INV = 173.43 (12' PROPOSED SAND FILTER SYSTEM #2 CLEANOUT PROPOSED SAND FILTER SYSTEM /3 DROP INLET INV = 173.58 (12' TOP=174.56 INLETRADES (TYP•) INV - 173.38 (12' INV. OUT=170.65 INLET PROPOSED SILT FENCE (1YP.) (PROVIDE INLET PROTECTION) m t 74.7!i� 1 �..��-- 6" IN IN=173 22 + 's �� �s �s "Sx.7 �"s, ��s '� INV. OUT=169.82 s + os J ' LIMITS DISTURBANCE (PROVIDE INLET PROTECTION) I STORMWATER ACCESS EASEMENT STORMWATER ACCESS EASEMENT (2.84 ACRES) c' I 'SSa, I I� I I� I STORM INLET STORM STORM PIPE _ INLET / STORM I d} INLET A / m / STORM / INLET1,\ / LIMITS OF DISTURBANCE / I ( (2.84 ACRES) - 0 15 30 60 SCALE 1" = 30' c 0 V Z 0 F-- Q 0 W Z J IL Z Z8d0 0 Q J 0 0 0 z O O IL z 0 LIJ Z Z m LLJ III 0 Z 0 E-- GRADING & DRAINAGE PLAN G The Stellar Architectural and ngineering Group, Inc. 2010. All rights reseryed. No part of this work may be used, reproduced, distributed, displayed or otherwise communicated in any form or by any means without the prior, written consent of The Stellar Architectural and Engineering Group. Inc. W N Z Z 0 0 V Q � U W 1 7 �F N Q 1 doB NO. 710 03986 DRAWN: RAF CHECKED: JRH SCALE: 111 = 30' C103 DRAWING NO. STEEL POSTS 6' E (MAX.) 60X6" VENT HOLE CAST IN SLAB WITH ALUMINUM GRATING, LOCATE I T(1=r11=1 I1=1 I� L= I yI OPPOSITE MOTOR CONTROL CABINET 1 DOUBLE DOOR ALUMINUM CHECKER PLATE I I I I=11� FILL OVER TOE jjT =nl III= HATCH COVER CAST IN TOP SLAB WITH COMPACTED I CAST ALUMINUM DROP HANDLE, 316 S.S. OF FABRIC BURIED 8" DEE II- HARDWARE, & RECESSED LOCKING AND 4" FORWARD ALONG TRENCH T�- - - DEVICES. DOORS TO PIVOT AS SHOWN AND BE H-20 TRAFFIC LOADKING BY NOTES: U.S. FOUNDRY, BILCO, OR APPROVED EQUAL 1. POSTS TO BE STEEL (1.33 LB/LF) WITH A MINIMUM LENGTH OF 5 FEET; LOCATE POSTS ON DOWNSLOPE SIDE OF FILTER FABRIC, POSTS MUST EXTEND 24" BENEATH SURFACE. CONCRETE TOP SLAB TO BE 2. BURY TOE OF FENCE APPROXIMATELY 8" DEEP TO PREVENT UNDERCUTTING. DESIGNED FOR H-20 TRAFFIC LOADING 3. WHEN JOINTS ARE NECESSARY, SECURLY FASTEN THE FABRIC AT A SUPPORT POST A WITH MINIMUM 4' OVERLAP TO THE NEXT POST. INFLUENT LINE - SEE 4. FILTER FABRIC TO BE NYLON, POLYESTER, PROPYLENE OR ETHYLENE YARN WITH EXTRA SITE PLAN FOR LOCATION STRENGTH - 50LB/LIN. IN. (MINIMUM) - AND WITH A FLOW RATE OF AT LEAST 0.3 GAL./ SQ. FT./MINUTE. FABRIC SHOULD CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS. FABRIC MUST CONFORM WITH ASTM D 6461. NO MORE THAN 24" OF FABRIC IS ALLOWED. LINED PRECAST CONCRETE TOP SLAB ABOVE GROUND LEVEL. TO BE 4,000 PSI CONCRETE WITH HATCH OPENING CENTERED IN WETWELL SEDIMENT FENCE 0 UNLESS OTHERWISE NOTED. CONCRETE & REINFORCING TO BE CERTIFIED BY THE ENGINEER OF RECORD, SUBMERSIBLE SEWAGE PUMPS TO BE LOCATED ALONG C.L. OF WETWELL UNLESS OTHERWISE NOTED un r� ao 0 0 o N N 00 m o r 1.5" TYPE S-1 ASPHALT a LO EXISTING In SMOOTH 0o SAWCUT 12" 12 ASPHALT PAVEMENT (NP) 1 MIN. I MIN. 0 N N d d O°o d O 'o o° d G O .0:: ° o O°a d d a° °d O°n ° oT .,� 0 %O ° °.: R) . EXISTING BASE 8" MIN. LIMEROCK BASE (LBR 75) 100% MAX. DRY DENSITY ASTM D-1557 COMPACTED BACKFILL 98% MAX. DRY DENSITY ASTM D-1557 LUG VALVES TO BE NON -LUBRICATED ECCENTRIC PLUG TYPE CLASS 175, SHUT-OFF REQUIRED AT 150 PSI IN BOTH DIRECTIONS. NOTE: THIS MAY REQUIRE A WORM GEAR OPERATOR IN 4" OR 6" VALVE. ALL PLUG VALVES 8" AND LARGER TO BE EQUIPPED WITH SEAT END WORMGEAR ACTUATORS. NON -BURIED VALVES WITH WORMGEAR ACTUATORS OF PLUG VALVE SHALL BE FURNISHED WITH SUITABLE SIZED HANDWHEEL OPERATORS. PLUG VALVE SEAT END TOWARDS WEI'WELL FOR 4" AND 6" VALVES, PROVIDE 1 VALVE WRENCH. VALVES SHALL ALLOW PASSAGE OF A SPHERICAL SOLID NOT LESS THAN PUMP CAPABILITY. .I. FLANGED 9o*BEND OPTION #1 _L I. FLANGED TEE P.V.C. DR18 PIPE PUMP MANUFACTURER ZOELLER "SHARK" MODEL 6840 GRIDER IMPELLER DISCHARGE 1T MOTOR RPM 3,450 �Q HP 460 VOLTS •1 PHASE HZ DESIGN POINT 2�..� GPM AT 70.0 FT.TDH RUNOUT POINT =GPM AT 5,.Q FT.TDH CHECK VALVE TO BE SWING TYPE WITH OUTSIDE 316 STAINLESS STEEL SPRING AND LEVER, CLASS 150 AS MANUFACTURED BY MUELLER OR APPROVED EQUAL WETWELL PLAN VIEW N.T.S. PUMP STATION INFORMATION SCHEDULE OF ELEVATIONS: TOP do LAG LEAD BOTH WET DISCHARGE DISCHARGE BOT. SLAB SOT. SLAB DROP SITE INFLUENT ALARM PUMP PUMP PUMP BOTTOM WELL PIPE F.M. OVERHANG THICKNESS INVERT GRADE ON ON OFF DIA. DIA. DIAL A B C D E F G H I J K L M 175.75 172.00 174.00 173.50 171.50 169.00 167.00 72 2" 2" 6" 6" MIN. 173.00 FLANGED SPOOL PIECE OR FLANGED FILLER AS NEEDED• GENERAL NOTES: 1. REFER TO SPECIFICATIONS, SECTION 02440, "SUBMERSIBLE WASTEWATER DOUBLE DOOR ALUMINUM CHECKER PLATE PUMPING STATION," HATCH COVER CAST IN TOP SLAB WITH CAST ALUM. DROP HANDLE, 316 S.S. DOORS TO S. HARDWARE, do RECESSED LOCKING DE2, ALL DUCTILE IRON FITTINGS AND PIPE SHALL BE HOLIDAY TESTED PRIOR PIVOT. AS SHOWN AND BE H-20 TRAFFIC TO INSTALLATION. LOADING BY U.S. FOUNDRY, BILCO, OR APPROVED EQUAL 3. DUCTILE IRON PIPE, FITTINGS AND BOLTS SHALL RECEIVE A THOROUGH EXTERIOR COATING OF BITUMINOUS COATING AS SPECIFIED IN A.N.S.I. SPECIFICATIONS A21.51. TRANSDUCER BRACKET 316 S.S. CABLE HOLDER 316 S.S. CABLE HOLDER LOCATED ON OPPOSITE LOCATED ON OPPOSITE SIDE AS DISCHARGE PIPES SIDE AS DISCHARGE PIPES 6'X6' VENT HOLE WITH RECESSED 1'X1'Xt" LINED CONCRETE ON TOP SLAB ALUMINUM GRATING. LOCATE OPPOSITE 24" MIN. ENTIRE AND INTO ALL OPENINGS IN TO CONTROL PANEL TOP OF GRATING TO BE CIRCUMFERENCE FLUSH WITH TOP OF CONCRETE.OF WETWELL FIELD LINE TOP SLAB AND WALL SECTION JOINTS. MAX. ANGLE FRAME ALUMINUM ANGLE FRAMEzzzl A A •• :. .. • . 1/Y SCHAD P.V.C. CONDUIT FOR TRANSDUCER TO 1/2' SCHAD P.V.C. CONDUIT FOR TRANSDUCER TO � MOTOR CONTROL CABINET. ATTACH WITH 316 S.S. MOTOR CONTROL CABINET. ATTACH WITH 318 S.S. BRACKETS. NO BENDS IN CONDUIT ALLOWED BETWEEN BRACKETS, NO BENDS IN CONDUIT ALLOWED BETWEEN • ° WEIWELL AND BEND AT MOTOR CONTROL CABINET. WEPMELL. AND SEND AT MOTOR CONTROL CABINET. ;. ; OF TRANSDUCER TO BE AT CENTERLINE OF BOTTOMOF TRANSDUCER TO BE AT CENTERLINE OF SEE NOTE NO. 5 PUMP VOLUTE PUMP VOLUTE. � o HIGH LEVEL INDICATOR MERCOID IN 1/2" SCH 40 PVC °: CONDUIT (TO MOTOR CONTROL CABINET). ATTACH WITH 316 S.S. BRACKETS. NO BENDS IN CONDUIT ALLOWED HIGH LEVEL INDICATOR MERCOID IN 1/2" SCH 40 PVC BETWEEN WETWELL AND SEND AT MOTOR CONTROL CONDUIT (TO MOTOR CONTROL CABINEr)ATTACH WITH]IFCABINET BASE LOCATION TO BE SO THAT MERCOID 316 S.S. BRACKETS. NO BENDS IN CONDUIT ALLOWED EXPERIENCES UNIMPEDED OPERATION. BETWEEN WETWELL AND BEND AT MOTOR CONTROL CABINEr BASE. LOCATION TO BE SO THAT MERCOID ;•• 6 •' , SEE NOTES NO. 5 FIELD EXPERIENCES UNIMPEDED OPERATION. FIBERGLASS OVER GRDUT .. ,•.... .. �.' AS SPECIFIED 316 STAINLESS STEEL GUIDE •• + 316 STAINLESS STEEL. GUIDE RAILS FOR PUMP REMOVAL RAILS FOR PUMP REMOVAL 316 STAINLESS STEEL UFTING CHAINS AND 316 STAINLESS STEEL LIFTING CHWNS AND APPROPRIATELY SIZED SHACKLES. PROVIDE 3'-0' APPROPRIATELY SIZED SHACKII PROVIDE Y-O" MIN. EXCESS LIFTING CHAIN. MIN. EXCESS UFTING CHWN._ SEE NOTES NO.4 LINER TO BE EITHER APPROVED COATING R ' VALVE BOX DRAIN WITH PVC TRAP MONOLITHIC FIBERGLASS INSERT. FIBERGLASS REINFORCED LINER TO BE EITHER APPROVED COATING R ;. PLASTIC (FRP) WETWELL LINER SHALL BE ONE PIECE PIPE BRACE REQUIRED. SEE PIPE ATTACHMENT WITH NO VERTICAL R HORIZONTAL SEAMS ALLOWED. MONOLITHIC FIBERGLASS INSERT. FIBERGLASS REINFORCED TO WALL DETAIL THIS SHEET. WAIL THICKNESS SHALL BE A MINIMUM OF 1/2' THICK PLASTIC (FRP) WETWELL LINER SHALL BE ONE PIECE H AND SHALL BE INSTALLED VERTICALLY IN AN EXISTING WITH NO VERTICAL OR HORIZONTAL SEAMS ALLOWED. PVC DR18 PIPE PIPE MUST ONE PIECE WHERE PRECAST CONCRETE WETWELL THE ANNULAR SPACE WALL THICKNESS SHALL BE A MINIMUM OF 1/2' THICK C POSSIBLE OTHERWISE, ONE JOINT WITH BELL JOINT BETWEEN THE CONCRETE WETWELL AND THE FIBERGLASS AND SHALL BE INSTALLED VERTICALLY IN AN EXISTING D ° ' RETAINER WILL BE ALLOWED WITH EPDXY COATED, D.I. LINER SHAD_ BE NO WIDER THAN 3' AND SHALL BE PRECAST CONCRETE WETWELL THE ANNULAR SPACE BODY AND STAINLESS STEEL FASTENERS k TIE BOLTS. FILLED WITH CONCRETE GROUT. BETWEEN THE CONCRETE WETWELL AND THE FIBERGLASS ,• LINER SHALL BE NO WIDER THAN 3' AND SHALL BE F FILLED WITH CONCRETE GROUT. °• FIELD FIBERGLASS JOINTS 4 FOR PIPE AS SPECIFIED PRECAST CONCRETE WETWELL SHALL MEET A S.T.M. C-478 AS RECOMMENDED BY PUMP STANDARD, ENTIRE INSIDE SURFACE OF WETWELL AI TOP AS RECOMMENDED BY PUMP MANUFACTURER. SEE NOTES No. 6 .° SLAB SHALL BE LINED WITH APPROVED LINER. LINER MANUFACTURER. SEE NOTES No. 6 INSTALLER MUST BE CERTIFIED BY LINER MANUFACTURER. SUBMIT CERTIFICATION WITH SHOP DRAWING SUBMITTAL DROP CONNECTION REQUIRED DROP CONNECTION REQUIRED SEE DETAIL ON THIS SHEET B SEE DETAIL ON THIS SHEET B 2 D.I. FLG. 45' BENDS BUTTED FACE TO FACE (IF REQUIRED) 2' MINIMUM AROUND WETWELL SEE NOTE N0. 5 -FIELD TO BE FILLED WITH A-3 SAND. FIBERGLASS OR APPLY LINER D.I. FLANGED ECCENTRIC INCREASER (IF REQUIRED) UNDISTURBED SOIL REQUIRED OVER INTERIOR GROUT AS SPECIFIED G TYP K ; . ' . BEYOND 2' SAND BUFFER . • a BASE ELL TO BE FABRICATED BY PUMP I • :a '• ' n i., �TO BE � ' . II L SIZEDFORMANUFACTURER. BASE F APPLICABLE • RAMNEK TYPE SEALANT OR OWNER APPROVED EQUAL 6" MIN. LEVELING °s •. ALL AROUND WHERE FIBER- - COURSE CONCRETE '• : 4 e : ME ' %•'+ :. ,'' GROUT FROM BASE PLATE TO A HQGHT OF 2' ABOVE GLASS AND CONCRETE TOGETHER _ ° 4'. ' �' BOTTOM AIl AROUND WITH CLASS C" CONCRETE ROUGHEN FIBERGLASS LINER WITH SAND PAPER CONCRETE AND FIBERGLASS I I l l lil I- III I- I I I- I TO INC�RE�ADHESIIOEN OR INSTALL FIELD APPLIED DESIGN TO BE SIGNED LINBY A FLORIDA REGISTERED CONCRETE AND REINFORCING ENGINEER. SUBMIT WITH 1' MINIMUM LEVELING SHOP DRAWINGS. STEEL DESIGN TO BE SIGNED COURSE PRECAST BOTTOM SLAB BY A REGISTERED ENGINEER. SUBMIT WITH SHOP / J DRAWINGS. UNDISTURBED EARTH DUPLEX SUBMERSIBLE SEWAGE PUMPS WITH UNDISTURBED EARTH INTEGRAL MOTORS AND SCREW IMPELLERS UNLESS OTHERWISE APPROVED. SEE NOTE 6 3 )1 LIFT STATION in FROM MAY 1 - AUGUST 31 FROM SEPTEMBER 1 - APRIL 30 U Z 1 POUND BROWNTOP MILLET 2 POUNDS ANNUAL RYE GRASS 2 POUNDS HULLED BERMUDA 0.5 POUNDS HULLED BERMUDA �I '0 25 POUNDS 10-10•-10 FERTILIZER 1.5 POUNDS UNHULLED BERMUDA 75 POUNDS LIMESTONE 25 POUNDS 10-10-10 FERTILIZER 75 POUNDS LIMESTONE OR OR 0 1 POUND BROWNTOP MILLET 1 POUND HULLED BERMUDA 2 POUNDS ANNUAL RYE GRASS *2 POUNDS BAHIA GRASS 0.5 POUNDS HULLED BERMUDA 0 25 POUNDS 10-10-10 FERTILIZER 1.5 POUNDS UNHULLED BERMUDA l� 75 POUNDS LIMESTONE 2 POUNDSBAHIA RA 25 OO FERTILIZER OR 75 POUNDS LIMESTONE -� DEEP SANDY SOILS OR 2 POUNDS BROWNTOP MILLET o *3 POUNDS BAHIA GRASS 1 POUND ANNUAL RYE GRASS 0 25 POUNDS 10-10-10 FERTILIZER 3 POUNDS FESCUE GRASS 75 POUNDS LIMESTONE 25 POUNDS 10-10-10 FERTILIZER �0 75 POUNDS LIMESTONE 00 0) OR DEEP SANDY SOILS 1 POUND UNHULLED BERMUDA rn 2 POUNDS RYE GRASS OR 2 LBS. GRAIN RYE *2 POUNDS BAHIA GRASS p 25 POUNDS 10-10-10 FERTILIZER 75 POUNDS LIMESTONE * BAHIA GRASS IS A GOOD EROSION CONTROL GRASS; HOWEVER, IT PRODUCES MANY raj SEED HEADS WHICH SCATTER TO ANOTHER AREA. BAHIA GRASS IS HARD TO MOW, BUT IT o DOES NOT REQUIRE THE CARE THAT OTHER GRASSES REQUIRE. AROUND OFFICE BUILDINGS AND WITHIN SUBDIVISIONS, USE 4 TO 6 OUNCES OF CENTIPEDE GRASS IN LIEU 0 a; 0 ** FOR SOILS WITH CLAY SUBSOIL. DO NOT PLANT IN SANDY SOILS. l SEEDING SCHEDULE LINED CONCRETE WETWELL ELEVATION SECTION A -A N.T.S. NOTES: ON ALL VEGETATED SWALES OR DITCHES WITH SIDE SLOPES (CUT OR FILL) ADD 4 TO 6 OUNCES PER 1 000 SQUARE FEET OF STEEPER THAN 2.1 D Q WEEPING LOVEGRASS SEED TO ANY OF THE ABOVE MIXTURES. SWALE AND DITCH BOTTOMS SHOULD BE DOUBLE SEEDED. ALL SLOPES STEEPER THAN 2:1 SHALL BE HYDROSEEDED. GROWTH OF RYE GRASS IN EARLY SPRING MUST BE SUPPRESSED TO PREVENT RYE FROM CHOKING OUT PERMANENT GRASS SUCH AS BERMUDA, BAHIA OR FESCUE. SCHEDULE REFLECTS REQUIREMENTS PER 1000 SO. FT. 1. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION THAT WALL PREVENT TRACKING R FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS - OF -WAY. THIS MAY REQUIRE TOP DRESSING. REPAIR AND/OR CLEAN OUT OF ANY MEASURES USED TO TRAP SEDIMENT. 2. WHEN NECESSARY WHEELS SHALL BE CLEANED PRIOR TO ENTRANCE ONTO PUBLIC RIGHT-OF-WAY. 3. WHEN WASHING IS REQUIRE. IT SHALL BE DONE ON AN AREA STABILIZED WITH RUSHED STONE THAT DRAINS INTO AN APPROVED SEDIMENT TRAP OR SEDIMENT BASIN. 5) 1 TEMPORARY CONSTRUCTION ENTRANCE RIDGE -50' MIN. ITI TRANSDUCER BRACKET 6"X6' VENT HOLE WITH RECESSED 1"X1"X1" ALUMINUM GRATING. LOCATE OPPOSITE CONTROL PANEL TOP OF GRATING TO BE FLUSH WITH TOP OF CONCRETE. X. 1/2"X1"X1' ALUMINUM ANGLE FRAME SEE NOTE NO. 5 4. ALL EXTERIOR JOINTS OF PRECAST CONCRETE WETWELLS SHALL BE SEALED WITH A RUBBERIZED ASPHALT MEMBRANE TAPE. TAPE SHALL BE PERM -A -BARRIER BY W.R. GRACE, ELASTOPLY BY KARNAK OR EQUAL 5. ALL ANNULAR OPENINGS IN CONCRETE SHALL BE SEALED WITH NON -SHRINK GROUT AND WATERSTOPS. 6. IF PUMPS TO BE INSTALLED ARE NOT SCREW IMPELLER PUMPS, MOUNTING BASE TO BE RAISED AS RECOMMENDED BY MANUFACTU- RER TO ACCOMMODATE FUTURE SCREW IMPELLER PUMPS. STP PIPE TO ANGLE WITH ; 3 8 318 STAINLESS STEEL UU BOLT, NUTS /WD WASHERS CONCRETE OR • FIBERGLASS WETWELL PVC PIPE % A A INSTALL 3'X3'X1/4" 316 STAINLESS STEEL ANGLE • 3/8' HILTI-TYPE ANCHOR BOLTS ° (318 SS BOLTS FOR FIBERGLASS WETWELL) a SECTION 'A -A' VALVE BOX DRAIN WITH PVC TRAP PIPE BRACE REQUIRED. SEE PIPE ATTACHMENT TO WALL DETAIL THIS SHEET. PVC DR18 PIPE. PIPE MUST BE ONE PIECE WHERE POSSIBLE OTHERWISE, ONE JOINT WITH BELL JOINT RETAINER WILL BE ALLOWED WITH EPDXY COATED, D.I. BODY AND STAINLESS STEEL FASTENERS & TIE BOLTS. 1/4" STAINLESS STEEL PLATE PIPE ATTACHMENT TO WALL DETAIL N.T.S. -REQUIRED FOR ALL PUMPING STATIONS - FIBERGLASS WETWELL SHALL BE AS SPECIFIED. PVC DR26 SANITARY SEWER 2 D.I. FLG. 45' BENDS BUTTED FACE TO FACE (IF REQUIRED) D.I. FLANGED ECCENTRIC INCREASER (IF REQUIRED) M BASE ELL TO BE FABRICATED BY PUMP MANUFACTURER. BASE ELBOW TO BE G SIZED FOR FUTURE PUMPS IF APPLICABLE ., • •...... �.. ..a . ', 12"MIN. v. ; 4 ...• . :' .�.. .• :.a .'' .i.�'.� .12"MIN. L I I III III -III III I I-1 I I -III -III -I 11-1 11- I =III=II I I I I I I -III I I I I I I=I I I=I I I=I I I -I COMPACT BOTTOM OF EXCAVATION TO 95% STANDARD PROCTOR DENSITY. POUR REINFORCED CONCRETE BASE 12' THICK AND 24" BEYOND WETWELL OUTSIDE WALLS. AS SOON AS THE CONCRETE HAS SET UP ENOUGH TO POURED IN PLACE SUPPORT THE WETWELL LOWER THE WETWELL INTO CONCRETE BOTTOM SLAB R 12' MINIMUM PLACE. POUR A MINIMUM OF 12 CONC ON THE INSIDE, ALSO A MINIMUM OF 12 DEEP AND 24" CONCRETE FROM THE FIBERGLASS WAIL ON THE OUTSIDE OF THE FIBERGLASS WETWELL FIBERGLASS SECTION A -A N.T.S. HARDWARE CLOTH PVC DR18 SANITARY SEWER D.I. M.J. 4F BEND OR PVC DR18 4T BEND (UP TO 8' (RESTRAINED JOINT) -� WETWELL WALL SECTION D.I. M.J. 45' BEND OR PVC DR18 4,7 BEND ° a R FIBERGLASS APPROVED (UP TO 8' WETWELL (RESTRAINED JOINT) 1' a .A CUT PIPE FLUSH WITH FILLET 0 . I °. ` GRAVITY DROP CONNECTION DETAIL N.T.S. -REQUIRED FOR ALL PUMPING STATIONS- BM 1. ALL ANNULAR OPENINGS IN CONCRETE SHALL BE SEALED WITH NON -SHRINK GROUT AND WATERSTOPS. FIELD LINE OVER INTERIOR GROUT AS SPECIFIED. SEDIMENT REMOVAL REQUIREMENTS SEDIMENT MUST BE REMOVED WHEN ACCUMULATIONS REACH A DEPTH OF ONE (1) FOOT (1/2 THE HEIGHT OF THE STONE.) GRAVEL - SUPPORTED BY HARDWARE CLOTH TO ALLOW DRAINAGE AND RESTRICT SEDIMENT MOVEMENT • . !l�I!i•I!i�0!x ri ,, _,, 11 1, _�I ,1 • ,• ••• • • 9 0§ --• • GROUND SUBGRADE EXCAVATED AREA (AS REQUIRED) 2 1 ggg R V P V) Z O a 0 W Z J 0- Z Z 04d. O O Z Q J O c) Z � O Q z CL O0 X Z W z Z) � Q 0 J D m I W Qf 0 Q Z O SITE DETAILS RThe Stellar Architectural and gineering Group, Inc. 2010. All rights reserved. No part of this work May be used, reproduced, distributed, displayed or otherwise communicated in any form or by any means without the prior, written consent of The Stellar Architectural and Engineering Group, Inc. W 4 cn z 0 U a7 Z U Ix MRj N Q m JOB NO. 710 03986 DRAWN: JCL CHECKED: JRH SCALE: N.T.S. C501 2 DRAWING NO. 0 0 c 0 J 0 0 0 to 0) rn M O rn rn rn C> 0 i 0 O O tM O u, 0 0 a; E 0 c M 1/4"x2"x2" A36 d STEEL ANGLE 45 PVC ELBOW SCRIBE THE SHAPE & SIZE OF THE DOWNSPOUTS (1/8 BEND) ONTO THE PVC CAP AND TRIM TO FIT, NOTES: CONNECTION NOTES: EXTEND DOWNSPOUT FACE OF g A MINIMUM OF 1" : ' BUILDING PVCROOF DRAIN HEADER 1. THIS INLET IS hX TRAFFIC RATED, AND SHOULD NOT BE USED IN AREAS Y3 1. INLET SHALL COMPLY WITH THE LATEST VERSIONS OF ASTM C 913-79, •' THAT RECEIVE ANY TYPE OF VEHICULAR TRAFFIC. PRECAST CONCRETE WATER AND WASTEWATER STRUCTURES, AND ASTM BELOW TOP OF THE • PIPE -SEE GRADING 4ki io C 890-913, MINIMUM DESIGN LOADING FOR MONOLITHIC OR SECTIONAL PVC CAP. MAINTAIN '''::' AND DRAINAGE PLAN PRECAST CONCRETE WATER AND WASTEWATER STRUCTURES. THE INTEGRITY OF EXTERIOR DOWNSPOUT FOR SIZE AND SLOPE 2. INLET SHALL COMPLY WITH THE LATEST VERSIONS OF ASTM C 913-79, THE DOWNSPOUT (SEE ARCH. FOR SIZE) PRECAST CONCRETE WATER AND WASTEWATER STRUCTURES, AND ASTM 2. CONCRETE SHALL BE 4000 PSI AT 28 DAYS, TYPE II CEMENT. a'. PLAN VIEW PLAN C 890-913, MINIMUM DESIGN LOADING FOR MONOLITHIC OR SECTIONAL CAST IRON GRATE CROSS-SECTION AT 10' PRECAST CONCRETE WATER AND WASTEWATER STRUCTURES. PLAN (SEE NOTES) 3. REINFORCEMENT FOR WALLS AND BASE SLAB SHALL BE #4 BARS AT THE POINT OF • ,• wow 12" EACH WAY, FOR STRUCTURES UP TO 24' DEEP. DESIGN IS FOR CONNECTION. 3. CONCRETE SHALL BE 4000 PSI AT 28 DAYS, TYPE It CEMENT. AASHTO H-20 TRUCK LOADING. M PVC CAP » �� .•• y 4. USE NO LARGER PIPE THAN 12" RCP OR 15" CMP TO ENTER THE t.. 4. USE NO LARGER PIPE THAN 18" RCP OR 21" CMP TO ENTER THE _ : FINISHED GRADE SIDES OF THE STRUCTURE. � SD •. 2'-0" SIDES OF THE STRUCTURE. USE NO LARGER THAN 24" RCP _. - CAST IRON GRATE ey 4 N I +« OR 30" CMP TO ENTER THE 3'-1" SIDES OF THE STRUCTURE. �' ~ 5. GRATE IS TO BE A US FOUNDRY NO. 6230, OR APPROVED EQUAL, :� H cn d ,•:• 2' (SEE NOTES) 2._0" .� o g • + ' ♦ 5. GRATE FOR NON -TRAFFIC AREAS IS TO BE A US FOUNDRY NO. 6210, ' • ; . •' • 6. INSIDE BOTTOM OF STRUCTURE IS TO BE A MINIMUM OF 12" BELOW THE •. , OR APPROVED EQUAL GRATE FOR ALL TRAFFIC AREAS EITHER LIGHT BUILDING FOUNDATION • ' LOWEST PIPE INVERT. ' DUTY OR HEAVY DUTY IS TO BEAUS FOUNDRY N0. 6212, OR APPROVED •'•• 1/2" DIA. ANCHOR EQUAL •':.w ^: ,•:: (2 PER SIDE) 24"MIN PVC PIPE 4e, 1'-10" 4" Q . a . S. SET INLET GRATE AT 0.05' BELOW GRADE IN ASPHALT PAVED AREAS, AND i i • ' . �. •• + •�- .• Q AT GRADE IN CONCRETE PAVED AND NON -PAVED AREAS. d WITH WATER -TIGHT a w y ' JOINTS (TYP.) .• :• .; ROOF DRAIN SERVICE LATERAL - SEE ROOF DRAIN HEADER z w PAVING &DRAINAGE PLAN FOR SIZE APIPE - ND DRASNAGE PLAN ¢ • : + +• REINFORCING + r'. Ji (SEE NOTES) /8 BEND�TYP.) FOR SIZE AND SLOPE r••; O a LAY PIPE AT tJi o !a 6" 1/8" PER FOOT • (TYP) MINIMUM SLOPE w PROFILE V. a0-4.SOIL MINIMUM BEARING +'` •d CAPACITY 2000 PSF :"'� `' SOIL MINIMUM BEARING Z ...: ::. I I � CAPACITY 2000 PSF F1 11-1 I I-J 11 111=1 I I 1 11=1 I I 1 I 1=1 I I_L-1 I 1=i i 1=1 I I-1 i I I I ICI i 1=1 i i=1 i I_I i I_ITi-I i 1=� =111 1111I I 11 1 1 I 11 1 I I I I 1 1 I I 11 1111 1 1 1� 1111L I 11 1 I 11 i 1 I 11 i 1I 11 i -I I i--Tl-1 11-1 I I -I 11-1 11-1 I I -I I IE 1 I 1=11 I-1 I I- i I I I _III -I i I-Ti-1 i 1-1 i 1-I i 1-1TI-1T1 SECTION SECTION Z Q STORM INLET 1 ROOF DRAIN CONNECTION 2 YARD DRAIN 7 C Q z Z �S o EXISTING STORM INLET W 20' O Z U 10' J O 2 VEGETATIVE SIDE SLOPES (TYP.) N � OVERFLOW Q Z (FOREBAY) (SAND FILTER CHAMBER) 3 3----------- O Q Z INFLOW (FROM ROOF DRAINS) X Z OUTFLOW PIPE GRAVEL/STONE SURFACE VEGETATIVE SIDEW n :...:... _ ... ,.. ........... .. ...: SLOPES S (TYP.) ,. .. SAND MEDIA 3 Q 0 1 OUTFLOW (UNDERDRAIN PERF. PIPE) _I m p SHWT I.N1..1 � r SAND FILTER CROSS SECTION 3 DETAIL * DETAIL * 0 T.O.B. = 174.50 T.O.B. = 175.00 B.O.P. = 173.00 Z B.O.P. = 173.50 8" HDPE PIPE O NV - 173.50 6" DOWNSPOUT 12" HEADER PIPE '/- INV = 173.50 �/- 6" DOWNSPOUT 8" DOWNSPOUT fINV = 173.66 INV = 173.50 INV = 173,50 (FOREBAY) INV = 173.50 (FOREBAY) INV = 173.00 I INV HEADER PIPE 12" HEADER PIPE J CONNECT UNDER - NV = 173.06 TOP OF BERM 174.00 INV = 173.06 DRAIN TO EX. INLET TOP OF BERM = 174.50 INV = 170.17 o PROVIDE OVERFLOW O N _ N SWALE TO EXISTING 4" UNDERDRAIN SYSTEM STORM INLET SITE INV = 170.17 8" HDPE OUTFLOW PIPE INV = 174.25 DETAILS 8„ HDPE OUTFLOW PIPE------------------------------------------------------------------------------------------------------------r------- ti -------------------------- -----I - - - - - - - - - ---- - - - - - - - - - -7--- 4" UNDERDRAIN SYSTEM- - --- ------------------------------------------------- ------------------------------------------------------------ INV -------------------- ---- = 170.67 -- - (SAND FILTER) INV = 172,96 ___ I C The Stellar Architectural and N (SAND FILTER) INV = 173.46 CONNECT UNDER- ------------------------------- ------- ---------' ----------------------------------------------------------------------- g part of this ngineering Group, Inc 2010. All rights may be used. work may di used, r otherwise I DRAIN TO EX. INLET T.O.B. = 174.50 distributed, displayed or otherwise communicated in any form or by T.O.B. = 175.00 I INV 170.67 B.O.P. = 172.50 any means without the prior, B.O.P. = 173.00 PROVIDE OVERFLOW written consent of The Stellar SWALE TO EXISTING 65' Architectural and Engineering Group, Inc. v STORM INLET 1 29 INV = 174.75 SAND FILTER SYSTEM #1 (1 "=5') 4 SAND FILTER SYSTEM #2 »_ (1 -5) 5 DETAIL * DETAIL * M Vl Z O O T.O.B. = 174.75 cr B.O.P. = 173.25 V) W n chi 6" DOWNSPOUT INV = 173.25 6" DOWNSPOUT INV = 173.25 (FOREBAY) INV = 173.25 / 12" HEADER PIPE 12" HEADER PIPE J INV = 173.25 TOP OF BERM = 174.25 INV 173.25 NI Q O �O PROVIDE OVERFLOW SWALE TO EXISTING 4' UNDERDRAIN SYSTEM r- STORM INLET INV = 170.42 8"- HDPE -OUTFLOW PIPE INV= 174.50 r---------------------- ----------------------- -------------------- -------------- I JOB NO. 710 03986 CONNECT UNDER- � I _ (SAND FILTER) ------------ -- DRAIN TO EX. INLET Jm INV = 170.42 INV 173.21 ENJCL -.-------L----------------------------------------------`---------------------------------------------- ---_ JRFi T.O. . = 174.75 B.O.P. = 172.75 59' N.T.S. 2 SAND FILTER SYSTEM #3 0"=5') 6 * DETAIL * DETAIL *0.