Loading...
HomeMy WebLinkAbout040034_Compliance Evaluation Inspection_20220620Facility Number ic.„9 0 Division of Water Resources 0 Division of Soil and Water Conservation 0 Other Agency ns 001,bdo Type of Visit: 0 Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: 0 Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: Farm Name: (tY) Arrival Time: O Departure Time: Ite irrn wner Name: vJhlt2 RocJ< ffIlYY1S Mailing Address: Physical Address: Owner Email: Phone: County: Region: frO ENTERED 10 I ASERFICHE J U N 21 2022 �0� � DEQ/DWR WQROS Facility Contact: FL)tQ Title: FAY�tLLE REGIONAL OFFICE Onsite Representative: C (1 fli.9.' Certified Operator: Back-up Operator: Location of Farm: roily Uel Latitude: Integrator: Certification Number: 9(177Y1S Certification Number: Longitude: Design Current Capacity Pop. Wean to Finish Wean to Feeder Feeder to Finish Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Other Layer Non -Layer Dry Poultry Design Current Capacity Pop. Design Current Capacity Pop. Layers Non -Layers Pullets Turkeys Turkey Poults Other Design Current Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow Non -Dairy Beef Stocker Beef Feeder Beef Brood Cow Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the State other than from a discharge? El Yes No ❑ NA ❑ NE ❑ Yes kl No ❑ NA ❑ NE ❑ Yes No ❑ NA ❑ NE ❑ Yes ❑ Yes ❑ Yes ❑ No No ❑ NA ❑ NE No ❑ NA ❑ NE ❑ NA ❑ NE Page 1 of 3 5/12/2020 Continued Facility Number: Waste Collection & Treatment Date of Inspection: 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? a. If yes, is waste level into the structural freeboard? Structure 1 Structure 2 Structure 3 Identifier: Spillway?: Designed Freeboard (in): Observed Freeboard (in): ❑ Yes ❑ Yes Structure 4 Structure 5 5. Are there any immediate threats to the integrity of any of the structures observed? (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environ 7. Do any of the structures need maintenance or improvement? 8. Do any of the structures lack adequate markers as required by the permit? (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes ❑ Yes ❑ Yes No ❑ NA ❑ NE No ❑ NA ❑ NE Structure 6 ❑ Yes No ❑ NA ❑ NE ❑ Yes No ❑ NA ❑ NE mental threat, notify DWR No ❑ NA ❑ NE No ❑NA ❑NE ❑ NA ❑ NE ❑ Yes ` No ❑ NA ❑ NE ❑Yes �No ❑NA ❑NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12Crop P"., srn(Iu qraiN; c,ONi 13., Type(s):G 1(1 C !'e44<1 whiteCt0Ke; c ree4 rn oo{e 14. Do the receiving crops differ from those designated in the CAWMP? 15. Does the receiving crop and/or land application site need improvement? 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acres determination? 17. Does the facility lack adequate acreage for land application? 18. Is there a lack of properly operating waste application equipment? Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check the appropriate box. ❑ WUP ❑ Checklists ❑ Design ❑ Maps ❑ Lease Agreements 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Yes ❑ Other: ❑ Yes ❑ Waste Tran No ❑ NA No ❑ NA No ❑ NA No ❑ NA No ❑ NA No No ❑ NA ❑ NA ❑ NE ❑ NE ❑ NE ❑ NE ❑ NE ❑ NE ❑ NE ❑ Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes Page 2 of 3 No ❑ NA ❑ NE ers ❑ Weather Code ❑ Sludge Survey No ❑ NA ❑ NE No ❑ NA ❑ NE 5/12/2020 Continued Facility Number: Date of Inspection: 24. Did the facility fail to calibrate waste application equipment as required by the permit? 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: ❑ Yes ❑ Yes No ❑ NA ❑ NE No ❑ NA ❑ NE 26. Did the facility fail to provide documentation of an actively certified operator in charge? El Yes No ❑ NA ❑ NE 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? 0 Yes No El NA ❑ NE Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes tly No ❑ NA ❑ NE and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes No ❑ NA ❑ NE permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Yes ❑ No ❑ NA ❑ NE ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: ❑ Yes No ❑ NA ❑ NE 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? ❑ Yes ❑ Yes ❑ Yes No ❑ NA ❑ NE No ❑ NA ❑ NE No ❑ NA ❑ NE Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain situations (use additional pages as necessary). reCOM INfO1 H1- wict-g ah4w 1).49.91, 1 iT al y l'vQg e ory y. 12. 601 r1ee9o1ri ciRa°� °p march 0-(9,9 Soil anniy5ls 2 7 gg. Reviewer/Inspector Name: Reviewer/Inspector Signature: Page 3 of 3 fc1-14-eMt 14)9J2J --Mot Phone: Date: Le; ord 5/12/2020