Loading...
HomeMy WebLinkAboutWQ0021934_Inspection_20220630DocuSign Envelope ID: D92E0F34-DEE1-491D-8A5F-0F94346A6F43 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Shannon V Becker - President Aqua North Carolina, Inc 202 MacKenan Court Cary, NC 27511 NORTH CAROLINA Environmental Quality June 30, 2022 Subject: Compliance Evaluation Inspection Aqua - Hasentree WWTF and Reclaimed Water Generation and Non -conjunctive reclaimed water utilization Nondischarge Permit WQ0021934 Wake Forest, NC Wake County Dear Ms. Parrish: On June 8 and 24, 2022, Dorothy Robson from the Raleigh Regional Office visited your facility to evaluate compliance with the Nondischarge Permit WQ0021934. Division records indicate the facility operates a reclaim facility, non -conjunctive utilization, and distribution of reclaimed water. During the inspection, the following was observed: Schedule (Section I of permit): 1. The flow rate and gallons per day has not exceeded the approved flow rate. 2. Appropriate education was observed and appeared to be sufficient to inform users and employees of the reclaimed water irrigation. Performance (Section II): 3. The facility maintains and operates the reclaimed water facilities as described in the permit. 4. All reclaimed water components are labeled or colored purple as described in the permit as well as signage located throughout the reclaimed water distribution area. 5. Irrigation application rates are applied to the fields as permitted. 6. No drinking water wells are located on or within the compliance boundaries. Operation and Maintenance (O&M) (Section III): 7. The permittee operates and maintains the reclaim water system and the distribution system as a non - discharge system. An O&M Plan, Spill control prevention plan (SPCP), and safety measures are readily available and observed. 8. Vegetative cover on the irrigation areas were well maintained and no ponding or runoff was observed. 9. Public access is restricted at the wastewater treatment and storage ponds. 10. Continuous monitoring and recording are utilized for turbidity. 11. Flow meters are maintained and calibrated yearly. 12. Standby power is maintained as described in the permit. 13. Freeboard in both the storage pond and upset ponds were below two feet. 14. The facility has established an education program to inform golfers and other guests of the reclaimed water irrigation system. DocuSign Envelope ID: D92E0F34-DEE1-491D-8A5F-0F94346A6F43 Page 12 Monitoring and Reporting (Section IV): 15. Reclaimed water is sampled and monitored for compliance in accordance with the permit. 16. Record tracking documents were well maintained and readily available for review. 17. Irrigation rates and flow is documented daily. 18. Reclaimed water effluent is monitored and sampled in accordance with Attachment A of the permit. 19. Reclaimed water utilization is tracked in accordance with Attachment B of the permit. 20. Maintenance Togs were observed to be complete. 21. Monitoring wells are sampled at the frequency in accordance with the permit. Inspections (Section V): 22. The facility performs maintenance and inspects the facility daily and maintains written and digital logs. General Conditions 23. The permittee is in compliance with the permit conditions. This report is a notification of the results of the compliance inspection. No violations were observed at the time of the inspection. If you have questions or comments about this inspection, then please contact via email at dorothy.robson@ncdenr.gov or 919-791-4241. Sincerely, ,-DocuSigned by: Vaan,t,sSa f . M.atn,ual `— B2916 E6AB32144 F... Vanessa E. Manuel, Assistant Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Attachment(s): NCDEQ Compliance Inspection Form Cc: Laserfiche Roger B Tupps <RBTupps@aquaamerica.com>