Loading...
HomeMy WebLinkAboutNC0083933_Compliance Evaluation Inspection_20220706 (2)United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) 1 21IIIIII 671 Transaction Code NPDES yr/mo/day Inspection IN I 2 LI 3 I NC0083933 111 121 22/05/19 117 Type 18 I O I IIIIIIIIIII Inspector Fac Type 19 I S I 201 I IIIIIIIIIII IIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved I 70 I I 711 172 I N I 73 _ I 74 71 I I I I I I I I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES oermit Number) Salem Quarters WWTP 9999 Rangecrest Rd Winston Salem NC 27103 Entry Time/Date 09:OOAM 22/05/19 Permit Effective Date 17/03/01 Exit Time/Date 09:30AM 22/05/19 Permit Expiration Date 22/02/28 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Morgan Lee Turner/ORC/336-996-2841/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Morgan Turner, /Old Beau Golf Club WQCSD0191/336-929-1288/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenar Records/Reports Facility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) /77Y6m. July 6, 2022 Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Gary Hudson DWR/Division of Water Quality/336-776-9694/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date IDocuSigned by: T. �,..i'dc.,- 7/6/2022 EPAFdi`hE%-SIWev 9-94) Previous editions are obsolete. Page# 1 sI NPDES yr/mo/day N C0083933 111 121 22/05/19 117 Inspection Type 18 [j 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) *The current permit expired 0n February 28, 2022. A renewal application was submitted on November 5, 2021. *The WWTP appeared to be well operated and maintained. No deficiencies or violations were noted during the inspection. *The ORC keeps very good records on -site. *New blower motors were installed in September 2019. A caustic feed system was installed in October 2019 for pH control. Page# 2 Permit: NC0083933 Inspection Date: 05/19/2022 Owner - Facility: Salem Quarters WWTP Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new MODE application? Is the facility as described in the permit? • ❑ ❑ ❑ # Are there any special conditions for the permit? El • El El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: The current permit expired 0n February 28, 2022. A renewal application was submitted on November 5, 2021. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable MODE Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The WWTP appeared to be well operated and maintained. No deficiencies or violations were noted during the inspection. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • El El El Is all required information readily available, complete and current? • El El El Are all records maintained for 3 years (lab. reg. required 5 years)? • ❑ El El Are analytical results consistent with data reported on DMRs? • El El El Is the chain -of -custody complete? • El El El Dates, times and location of sampling • Name of individual performing the sampling • Results of analysis and calibration • Dates of analysis ■ Name of person performing analyses • Transported COCs • Are DMRs complete: do they include all permit parameters? • El El El Has the facility submitted its annual compliance report to users and DWQ? • El El El (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified El El • El operator on each shift? Is the ORC visitation log available and current? • El El El Is the ORC certified at grade equal to or higher than the facility classification? • El El El Page# 3 Permit: NC0083933 Inspection Date: 05/19/2022 Owner - Facility: Salem Quarters WWTP Inspection Type: Compliance Evaluation Record Keeping Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: The ORC keeps very good records on -site. Yes No NA NE • ❑ ❑ ❑ Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? • ❑ ❑ ❑ Are surface aerators and mixers operational? • ❑ ❑ ❑ Are the diffusers operational? ■ ❑ ❑ ❑ Is the foam the proper color for the treatment process? • ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? • ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ • Is the DO level acceptable?(1.0 to 3.0 mg/I) ❑ ❑ ❑ • Comment: New blower motors were installed in September 2019. A caustic feed system was installed in October 2019 for pH control. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Comment: None. Yes No NA NE ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • Page# 4