Loading...
HomeMy WebLinkAboutNC0084425_Permit (Modification)_20101208NPDES DOCUMENT ! CANNIN`: COVER :SHEET NPDES Permit: NC0084425 Davidson Water WTP Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Staff Report Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Permit History Document Date: December 8, 2010 This documeat is printed on reuse paper - ignore Early coateat on the reszerse side ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director December 8, 2010 Mr. Gregg Stabler Davidson Water, Inc. P.O. Box 969 Welcome, N.C. 27374-0969 Dee Freeman Secretary Subject: Modification of NPDES Permit NC0084425 Minor Outfall Relocation Davidson Water WTP Davidson County Dear Mr. Stabler: ,The Division has reviewed the modification request submitted by your consultant (Brian Sexton of Marziano & McGougan). The Division has no objection to your proposal. The outfall relocation will not result in any change in discharge characteristics. The minimal distance of the relocation [ca. 600 feet] does not change the basis for any current permit limits or monitoring frequencies, which remain unchanged by this modification. This modification is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). This modified permit includes the following changes from your current permit: ➢ The permit map has been revised to show the new outfall location. Insert the map into your permit after the relocation is completed.. If any parts, measurement frequencies or sampling requirements contained in this modification are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 512 North Salisbury Street, Raleigh, North Carolina 27604 Phone: 919 807-6300 / FAX 919 807-6495 / Internet: www.ncwaterquality.org An Equal Opportunity/Affirmative Action Employer— 50% Recycledll0% Post Consumer Paper NorthCarolina Naturally This permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division or permits required by the Division of Land Resources, the Coastal Area Management Act or any other Federal or Local governmental permit that may be required. 'If you have any questions concerning this matter, please contact Charles H. Weaver at (919) 807-6391 or via e-mail [charles.weaver@ncdenr.gov]. Sincerely, r�o Coleen H. Sullins U cc: Central Files Winston-Salem Regional Office / Surface Water Protection NPDES Unit Brian Sexton / Marziano & McGougan [1300 Second Avenue, Suite 211, Conway, SC 29526] Latitude: 35°51'08" Longitude: 80°23'05" USGS Quad: Churchland, N.C. Stream Class: WS-IV CA Subbasin: 03-07-04 Receiving Stream: UT Yadkin River River basin: Yadkin -Pee Dee Hydrologic Unit: 03040101 NC0084425 Davidson Water WTP Davidson County Facility Location Map not to scale uT1 MARZIANO & MCGOUGAN, P.A. consulting engineers Marziano & McGougan, P.A. 1300 Second Avenue Suite 211 Conway, SC 29526 Phone: 843-488-0124 Fax: 843-488-0129 November 22, 2010 Mr. Charles Weaver NCDENR Division of Water Quality Surface Water Protection Section - NPDES Unit 1617 Mail Service Center Raleigh, NC 27699-1617 RE: Davidson Water, Inc. NPDES Discharge Relocation Request Dear Mr. Weaver: Davidson Water, Inc. requests to relocate the current NPDES discharge point (Yadkin River) to a more readily accessible point, approximately 600' upstream on the Yadkin River to handle the backwash water from the WTP as well as site runoff. The ongoing construction at the plant site requires this relocation. According to our conversations with your office, this project is a minor modification to the existing NPDES permit and will not require an ATC. Please see the attached design sheet for the proposed discharge relocation and pipeline. The plant water can discharge via 36" RCP inside the existing fence line. The excavated area will be approximately 6' below existing grade to the invert of the pipe. Some minor grading will be necessary to accommodate the new RCP installation, but no grading impacts to the river bank itself are expected. After the trench is excavated and the pipe installed, the downstream area will be armored with rip -rap (30' 1 x 15' w) to dissipate the flow energy as it enters the natural draw leading to the river. This fill is being coordinated with John Thomas, USACE, and necessary permit modifications are underway. If you have any questions or if we can provide additional information, please contact me at (843) 488-0124. L 2 32010 DENR-WATER QUALITY POINT SOURCE BRANCH A Bain -Foster Glass County: Vance ` ream Clas Receiving Stream: UT Martin Latitude: 36° 17' 20" Longitude: 78° 23' 35" W $ub-Basin: Grid/Ouad: C NS 03 s =02 25SW North Discharge Point (001) Weaver, Charles From: Weaver, Charles Sent: Friday, November 19, 2010 11:00 AM To: 'Brian Sexton' Cc: 'gstabler c@davidsonwater.com'; Tedder, Steve; Carter, Jenifer Subject: RE: Davidson Water Plant Site - NPDES Discharge relocation Brian —given the particulars of this relocation, we can handle it as a minor modification. Have the Permittee write a letter requesting the modification with the drawing attached. You can submit the request if the Permittee designates you an Authorized Representative. Please keep in close contact with the Winston-Salem Regional Office throughout the relocation. Consult with them regarding the potential need for an Authorization to Construct permit for the new outfall. CHW From: Brian Sexton jmailto:bsexton(@ marziano-mcaougan.comj Sent: Friday, November 19, 2010 9:46 AM To: Weaver, Charles Cc: 'Gregg Stabler'; 'Joseph McGougan' Subject: Davidson Water Plant Site - NPDES Discharge Charles, As I described in our conversation, Davidson Water, Inc. would like to relocate the current NPDES discharge point (Yadkin River) to a more readily accessible point, approximately 600' upstream on the Yadkin River to handle the backwash water from the WTP. The ongoing construction at the plant site requires this relocation. Please let me know if this is a mino(modification to the existing permit. Thanks, Brian Sexton, P.E. MARZIANO & McGOUGAN, P.A. South Carolina Office 1300 Second Avenue Suite 211 Conway, SC 29526 843 488-0124 phone 843 488-0129 fax 843 995-3303 cell G Uti Gv £// 5ez19 1 Ya'Mn000NL CINVIAVVi j Nvld 3±IS TTH83i\O -6141i+64- •! J J. euguea upoN'Aiunoa uosp nea aavaadn ddM 'ONI'a3iVM NOSOIAVO 8 o DENR SUBMITTAL Latitude: Longitude: USGS Quad #: River Basin #: Receiving Stream: Strearn Class: 36° 17' 20'. 78° 23' 35" — B2SSW 03-03-02 UT Martin Creek C NSW P 4 . . ,..—... • i . ii \ ,,A : :: a ...... • I , • ,...;,: d , „.•• : • 1 ! : ..„,_,.../. i .1 .1 Saint 620 Hen Van NCO .2 ; Pt-5077:1 • 'Rs p ,r•-) • ) nty 8- OHWM 675 YADKIN RIVER ORDINARY HIGH WATERMARK APPROX'r ELEV. = 65150' I EXIST. UNDERGROUND I ELECTRICAL LINE 1 I EXIST. FENCE LINE TO REMAIN IN PLACE 1 30'xl5' RIP -RAP ENERGY 1 PIS51PATER 1 STA 6+'15 36" INV. = 655.19' ��t EXIST. 24" 0.IP,. 42" DJ. "SUCTION LINE TO PUMP STATION! h •;,, 'A li/i 11ihi1144911 /! I1111/1/1/1111(lll 1.I rh,.4ili, lh.nllr EXIST. RAW WATER INTAKE RESERVOIR NO. 1 I. ;I ; . 1 ' Es�,�: Iljli `V 11 I j: ` R. ;, II \ I EXIST. `` { 1 1 1 h " I. GLEAWELL IiII \ _\ t STA 0+3T35 }`I (! .. \ i 6'4, MANHOLE A 6" INV- = 66322'Ito • _ �' `', 1 `i. 36" INV- = 656 y' t 1 NEW 42" RAW WATER EC7 TOE \ �� `x �� MAIN TO PLANT % 8•-D : T LINE `� ,- \� �: -- ss3 —• `•-_=� EXIST. 1 EAWELL Arma Aiidi--.4%.,, .... -•-•-.,..,.----„,—__Einr. :mit" , 4....,,,...... �� US LI d� 1f1 = i.— . I / EXIST. ISUCTI N LINE EXIST. ELECTRICAL DUCT BANK 24"x24" M.J. TEE 24" BFV EXIST. 16" EXIST. 16" DRAIN LINE SUCTION LINE I 24" ° j RESERVOIR NO. 2 A PLAN 4 PROFILE SCALE: 1"=50' HORIZONTAL I"=5' VERTICAL 670 665 YADKIN.RIVER--- NEW GRADE - EXIST- 24' NEW.36" RCP- --: =_ DECANT LINE s 52% �h45 ' St1 1J_ ,a�1NneNEr� — — 42" D.I. OVERFLOW LINE 42" D-I- BYPASS LINE �?r,• 675 NEW a* will r DECANTTLINE g: 52% . \. _ : 03 u —• 2:'M EXIST. GRADE. LST 2j= Reid WATER:t1.AN 4 ELEV.--=_:65954 EXIST 16 6 IN LINE 1 • ELEV 66 J0 660 655 Arr R07 OINWM ELEV. p= 65150 -- INV:. ELEV: 4 655.19' 2 :=ktST 24 -5U OC L1NE ELEV TO BE DETERMINED IN T1. FIELr7-.........--..__- EXIST- 16"-.SUCTION-..-: LINE i ELEV.- I.O BE': IDETE yED-1N-`IHE FIELD SLOPE = 0.49*. 670 665 663.41'- 660 1 - IV. AO Rill LIRE TO pa ABANDONED r u I 4 EL-E 6 E 0 4~ ovE6�1:ow LINE - -� EXIST i6 AC RW LINE 4`ELEV: i 65325 _. _ SO;BELABANDONE ELEV- 65515' TRANSFER LINE TO BEI, ABANDONED - 655 - T.IFintiVGROLND ELECTRICAL.'LINE" 42 D.I. SUCTION -LINE - IU Mf�u''��r' F71 A] -I U3 ELEVI 646:15 . _ a_--. 650 42 D I BYPASS-64NE . .-.. _4 ELEV 652.b0' 645 NEWl42".I2AW WATER MA TO PLANT:2 REVISIONS DESCRIPTION 640 4 e�kv. , bv'754 3+00 2+00 1+00 nilMARZIANO & MCGOUGAN, PA consulting engineers 1300 SECOND AVENUE • SUITE211 • CONWAY, SC 2952E Phone: 843.488.OL*4 Fax: 843.488.0129 NC License No C-6+4 oo+0o 635 NEW DECANT LINE PLAN & PROFILE 4f'a \ `\ - \ TO.PL-ANT 5EE PEAK.•. • \ \`. DRAWINGS FOR CON'T,'N\ \\\\\\\\\ \ \ \ \\I1\\�y1 \\N1\\\\I�\\\\ . h\\IIti\1\101\1\)4\1�1�''� —`\'\\.,1' E�SF:"fZ"-AC�WNE \Z• n` `\, \ \;;, BEQBANMONED,� f7t'�riuk1€ \"cr 4Il�)111 i, r/I iI19IIJll/�I11��;{/ � �\�, \ t;II!I � :i/Iff/l/���/%// /1N/ 41d/I1 tI'r—TO�E7-+BAN_DOIEl �'`_�'---->11\ //I'N� 1, / y/ f —i— \ ' }t h�1 .0 — hi iIIl/ Y �, f / /!/•erl^%\�L FOR BIDDING RESERVOIR 675 : ®:' 1 670 665 ■ 660 655 EXIST_ UNDEUND rC'1 BANK, EX15T. GRADE --- 66062 ± Jl. EXIST 6'• WATER-LIh ELEV = "66050' 1 1 ESERvoIR NO..2. 675 -. NEW C-RAWE _ NEW ROAD .,f\ WATER -LEVEL - 650 EXIST:24 RAW WATER MAIN -i EtEvz-'Y35eJ 670 665 EXIST ATER LiVLL 66052 s 660 W.42"_RAW WATER AIN TO_PLANT 4 ELEV 65954' 1NEW.36". RCP 1 DECANT, LINE 655 650 645 640 EXIST: Ire.AC 1U LINE TO BEms E. t ELEV6N4D9'.68`J. 645 EXIT. AC RUJ.LINE •":" tPrEC� ELE 65194` `EXIST 16- LINE csoNED 4 ELEV. =" 65Lt0' 640 635 635 SECTION A -A DAVIDSON WTP RESERVOIRS DAVIDSON COUNTY - NORTH CAROLINA Scale: AS SHOWN Date: 11-22-2010 Drawn: ALR Checked: JWM Job No.: 29019 Sheet No.: 1 Of:-1 Version: