Loading...
HomeMy WebLinkAboutNCG030394_Monitoring Report_20211108*ftw ,`/ ations xcellence ' inc. October 2021 Mr. James Moore NCDEQ Division of Energy, Mineral, and Land Resources Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 Subject: Report of Stormwater Sampling — 3Q 2021 Commercial Fabricators, Inc. 2045 Industrial Drive Newton, Catawba County, North Carolina NCDEQ Certificate of Coverage #NCG030394 Dear Mr. Moore: Attached is a stormwater sampling report for the subject facility. If you have any questions regarding this submittal, please contact the undersigned at 336-382-6849. Sincerely, Jeff Gerlock, L.G. NC Licensed Geologist #1141 Attachments — SW Discharge Monitoring Report Form Cc: Mr. John R. Tucker, Jr, Commercial Fabricators Operations Excellence, Inc., 2235-E Lewisville-Clemmons Road Clemmons, North Carolina 27012— 336-766-2913 ..k NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0394 Person Collecting Samples: Jeff Garlock Facility Name: Commercial Fabricators Laboratory Name: Meritech Facility County: Catawba Laboratory Cert. No.: 165 Discharge during this period: Ej Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances?Yes +❑ No If so, which Tier (I, 11, or III)? A copy of this DMR has been uploaded electronically via https://edocs.dec].nc.gov/Forms/SW-DMR []yes No Date Uploaded: October 2021 '`/ Analytical Monitoring Requirements for Outfalls with Industrial Activities— Benchmarks in (Red) Parameter Parameter Outfall OF-1 Outfall OF-2 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date Sample Collected MM/DD/YYYY 9-21-2021 9-21-2021 46529 24-Hour Rainfall in inches 0.12 0.12 C0530 TSSin mg/L (100or50") 12 17 PH in standard units (6.0-9.0 FW, 00400 7.63 7.69 6.8-8.5 SW Copper, total recoverable in mg/L 01119 0.010 FW, 0.0058 SW 0.010 0.007 Lead, total recoverable in mg/ L OSO51 0.075 FW, 0.22 SW) <0.010 <0.010 Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 0.647 0.143 Chemical Oxygen Demand (COD) in 00340 mg/L(120) 25 77 00552 1 Non -Polar Oil & Grease in mg/L (15) <5 <5 ' Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary NurseryAreas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, orthose persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of rmfttee or Delegated Aut orized Individual jtucker@commfab.com Email Address 3 zi Date 828-465-1010 Phone Number