Loading...
HomeMy WebLinkAboutNC0028711_Compliance Evaluation Inspection_20220627 (2)ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director George M. Jones Charlotte Mecklenburg Board of Education 3301 Stafford Drive Charlotte, NC 28208 SUBJECT: Compliance Evaluation Inspection Berryhill Elementary WWTP NPDES Permit No. NC0028711 Mecklenburg County Dear Mr. Jones: NORTH CAROLINA Environmental Quality June 27, 2022 Enclosed is a copy of the Compliance Evaluation Inspection (CEI) Report for the inspection conducted at the subject facility on June 20, 2022, by Mr. Wes Bell of this Office. Please advise the facility's Operator -in -Responsible Charge (ORC) of our findings by forwarding the enclosed report. As discussed in the inspection report, a new ORC was identified on the October 2021 monitoring report but has not been officially designated by the School System as required by 15A North Carolina Administrative Code (NCAC) 08G .0201 and subject NPDES Permit. This Office requests that the new ORC and any new Backup ORCs be designated on the approved documentation and submitted to the Division within fourteen (14) days of letter receipt. Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192 or at wes.bell@ncdenr.gov. Enclosure: Inspection Report Cc: NPDES Program Files - Laserfiche DE Sincerely, 1-DocuSigned by: '-A14CC681AF27425... W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ North Carolina Department of Environmental Quality I Division of Water Resources Mooresville Regional Office 1610 East Center Avenue. Suite 301 1 Mooresville. North Carolina 28115 704.663.1699 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 IL I 21 1 1 1 1 1 NPDES yr/mo/day Inspection 3 I NC0028711 111 121 22/06/20 117 Type 18 i i I I 1 1 1 Inspector Fac Type 191 S I 201 1 1 1 1 11 1 1 1 I I I 1 1 1 1 1 1 I I I I I 1 11 1 1 1 I 1 P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67I2.0 I 70I4 I 71IN I 72 I N I 73I I 74 751 I I 1 I I I I I I 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES Dermit Number) Berryhill Elementary School WWTP 10501 Walkers Ferry Rd Charlotte NC 28208 Entry Time/Date 09:15AM 22/06/20 Permit Effective Date 20/08/01 Exit Time/Date 11:15AM 22/06/20 Permit Expiration Date 25/06/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Dustin Kyle Metreyeon/ORC/704-506-4255/ Jeffery G Mitchell//980-343-8632 / Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted George M Jones,3301 Stafford Dr Charlotte NC 28208/Director of Maintenance/704-343-6040/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signatu Wes Bell e(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date ,-DocuSigned by: 1,0 , 3det DWR/MRO WQ/704-663-1699 Ext.2192/ 6/27/2022 -A61696D9OCC3437... Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger DWR/Division of Water Quality/704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. DocuSigned by: 6/27/2022 Page# 1 "-A14CC681AF27425... 3I NPDES yr/mo/day N C0028711 111 121 22/06/20 17 Inspection Type 18 [j 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) RECORD KEEPING SECTION cont'd: The "new ORC box" was checked on the October 2021 eDMR; however, the ORC has not been officially designated by the Permittee. Please be advised that the Permittee must properly designate the ORC and any new Backup ORCs as required by 15A NCAC 08G .0201 and NPDES Permit. Page# 2 Permit: NC0028711 Inspection Date: 06/20/2022 Owner - Facility: Berryhill Elementary School WWTP Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new El El • ❑ application? Is the facility as described in the permit? • El El El # Are there any special conditions for the permit? El El • El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • El El El Comment: The last compliance evaluation inspection at this facility was performed by DWR staff on 9/27/2019. Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ ❑ ❑ • ❑ Page# 3 Permit: NC0028711 Inspection Date: 06/20/2022 Owner - Facility: Berryhill Elementary School WWTP Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Comment: The records reviewed during the inspection were organized and well maintained. Discharge Monitoring Reports (eDMRs) were reviewed for the of May 2021 through April 2022. A daily maximum effluent fecal coliform violation was reported in March 2022. The December 2021 and January through March 2022 eDMRs were submitted late. The Division has previously addressed these violations through the issuances of a Notice of Deficiency (NOD), Notice of Violation (NOV) and NOV/civil penalty assessments. The March 2022 eDMR did have the ORC/Backup ORC visitations documented after 3/19/22. In addition, the downstream temperatures and times were the same on the January 2022 eDMR. Both eDMR will be revised and resubmitted. Several transcription errors regarding sampling times (either not listed or on wrong day) were noted during the eDMR review. The ORC and staff must ensure to thoroughly review all eDMRs to ensure all sampling times are properly transcribed prior to future submittals. Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Comment: On -site field analyses (dissolved oxygen, pH, temperature, total residual chlorine) are performed either under Metwater's field lab certification #5615 or Charlotte Board of Education/Berryhill Elementary's field lab certification #5512. K& W Laboratories has been contracted to perform effluent analyses (all permit -required parameters except field). Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ • ❑ Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? ❑ ❑ • ❑ Is the tubing clean? El El • El # Is proper temperature set for sample storage (kept at less than or equal to 6.0 El El • El degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • El El ❑ representative)? Comment: The subject permit requires effluent grab samples. Upstream / Downstream Sampling Yes No NA NE Page# 4 Permit: NC0028711 Inspection Date: 06/20/2022 Owner - Facility: Berryhill Elementary School WWTP Inspection Type: Compliance Evaluation Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, • ❑ ❑ ❑ and sampling location)? Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ME ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The wastewater treatment facility appeared to be properly operated and well maintained at the time of the inspection. Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Equalization Basins Is the basin aerated? Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Are audible and visual alarms operable? # Is basin size/volume adequate? Yes No NA NE • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ Comment: The equalization basin is equipped with a bypass pipe into the aeration basin. The equalization basin is also equipped with a telemetry type alarm system (high water) that operated properly during the on -site test. Aeration Basins Yes No NA NE Page# 5 Permit: NC0028711 Inspection Date: 06/20/2022 Owner - Facility: Berryhill Elementary School WWTP Inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? • ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ • ❑ Are the diffusers operational? • ❑ ❑ ❑ Is the foam the proper color for the treatment process? • ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? • ❑ ❑ ❑ Is the DO level acceptable? • ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/I) • ❑ ❑ ❑ Comment: Soda ash is added to the aeration basin on an as -needed basis to maintain appropriate alkalinity/pH levels. Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ • ❑ • ❑ ❑ ❑ Comment: The wastewater staff have been periodically removing algae accumulations/mats in the clarifiers. Disinfection -Tablet Yes No NA NE Are tablet chlorinators operational? • ❑ ❑ ❑ Are the tablets the proper size and type? • ❑ ❑ ❑ Number of tubes in use? 1 Is the level of chlorine residual acceptable? • ❑ El El Is the contact chamber free of growth, or sludge buildup? • El El El Is there chlorine residual prior to de -chlorination? • El ❑ ❑ Page# 6 Permit: NC0028711 Inspection Date: 06/20/2022 Owner - Facility: Berryhill Elementary School WWTP Inspection Type: Compliance Evaluation Disinfection -Tablet Yes No NA NE Comment: De -chlorination Type of system ? Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de -chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de -chlorinators operational? Number of tubes in use? Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: The flow meter is calibrated annually and was last calibrated on 10/11/21 by Clearwater, Inc. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: The effluent appeared clear with no floatable solids or foam. The effluent is discharged into the receiving stream via submerged outfall. Yes No NA NE Tablet • ❑ ❑ ❑ ■ ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ • ❑ ❑ ❑ • Aerobic Digester Yes No NA NE Is the capacity adequate? • ❑ El El Is the mixing adequate? ■ ❑ ❑ ❑ Is the site free of excessive foaming in the tank? • ❑ ❑ ❑ # Is the odor acceptable? • ❑ ❑ ❑ # Is tankage available for properly waste sludge? • ❑ ❑ ❑ Page# 7 Permit: NC0028711 Inspection Date: 06/20/2022 Owner - Facility: Berryhill Elementary School WWTP Inspection Type: Compliance Evaluation Aerobic Digester Yes No NA NE Comment: Greenway Waste Solutions is currently contracted to remove wastewater solids. Page# 8