Loading...
HomeMy WebLinkAboutWQ0041329_Application (FTSE)_20220518Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION Application Number. ifq Q U 0 t i 391 0, be completed by DWR) All items must be comnleted or the application will be returned I. APPLICANT INFORMATION: I. Applicant's name: Town of Fuquay-Varina (company, municipality, HOA, utility, etc.) 2. Applicant type: D Individual ❑ Corporation 0 Federal ❑ State/County ❑ General Partnership ❑ Privately -Owned Public Utility Municipal ❑ Other 3. Signature authority's name: per 1.SA NI AC 02T 0106 hh Michael Wagner Title: Public Utilities Director 4. Applicant's mailing address: 401 Old Honeycutt Road City: Fuquay-Varina State: NC Zip: 27526 5. Applicant's contact information: Phone number: (919) al-3911 Email Address: mwaener®.fuquav-varina.org Raleigh Regional Office 7C Dept of Environmental Quality MAY 1 8 1822 II. PROJECT INFORMATION: 1. Project name: Arlington Meadows 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ0041329 and issued date: 12/20/19, For modifications, also attach a detailed narrative description as described in Item G of the checkitat. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Wake 4. Approximate Coordinates (Decimal Degrees): Latitude: 35,560908° Longitude:--78,785985° 5. Parcel ID (if applicable): 0665299258, 0665395486_ (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Kirbv R. Bell. Jr License Number; 14023 Firm: Bass, Nixon & Kennedy, Inc. Mailing address: 6310 Chapel Hill Road, Suite 250 City: Raleigh State: NC Zip: 27607 Phone number: (919) 851-4422 Email Address: Robbie.Bell(abnkinc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Harnett Co. WWTP Permit Number: NC 0021636 Owner Name: Harnett County V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ0040793 2. Downstream (Receiving) Sewer Informations$ inch NOTE: Truehomes USA has assigned BNK.Inc as the new Engineer of Recor for Arlington Meadows. Spaulding -Norris, PA, original Engineei of Record has also given BNK, Inc. permission to use their Arlington Meadows approved plans for this submittal 0 Gravity 0 Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00193 Owner Name(s): Town of Fuquay-Varina FORM: FTA 06-21 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ® N/A 2. If the Applicant is a Developer of lots to be sold, has a figtiow s Operational Ajeernent (FORD: M been attached? ❑ Yes ❑ No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an j-10A/ A_(hErai a! A .rrcn nt (F QljMJ OA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑Yes ❑No ®N/A 4. Origin of wastewater. (check all that apply): ® Residential (Individually Owned) ❑ Residential (Leased) ❑ School / preschool / day care ❑ Food and drink facilities ❑ Businesses / offices / factories ❑ Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool/Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 1 S A isicAC Q T 0103 0j) If Industrial, is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under Imo. N (,A i 21 . [� 1 k 4t fj? ® Yes ❑ No 9 If ves. provide a cony of flow reduction approval letter with this annlicatlon 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(0) Daily Design Flow''" No. of Units Flow Single Family Units 300 gal/unit 20 6,000 GPD 225 gal/unit 62 13,950 GPD gall GPD gal/ GPD gal/ GPD gal/ GPD Total 19,950 GPD a See t 5 A NL.AL Q2T ,.q 114(b). (y , Mr j (e k.21 for caveats to wastewater design flow rates (Le., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to housed as vacation rentals as defined in i42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table ISA NC'A( 0 1%0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: }.9.95,4 GPD (per O5A NL C 021:1 ) > Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T AMC & h3 (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 1937 PVC 8 2379 PVC-C900 8 239 DIP ➢ Section 1I & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section in contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing Iines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) _t T .030 & h3AC._(PntonJlat 9rce Main* EgOVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: N/A 2. Approximate Coordinates (Decimal Degrees): Latitude: ° Longitude: - ° 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic bead (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01 C.1.b. 0 Grinder Pump ❑ Mechanical Bar Screen 0 Other (please specify) b. Power reliability in accordance with 1)A 7NCAC. L121 .0:i05 3i11): ❑ Standby power source or 0 Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B)_ > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0): 1. Does the project comply with all separations/alternatives found in 15A hy NCAC 02 f 2)51.t j? ® Yes 0 No 15A NCAC 02T.0305(fj contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 2Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 2Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches _ Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class 11 impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet •*Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches > If noncompliance with 07T :105(1) or (r;l, see Section X.1 ofthis application * i,5f p tr flC T0 contains alteratives where separations in O A30-7,(f k cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's RC Sur#acc Water (.ias Ili .#IQn . web gr 2. Does this project comply with the minimum separation requirements for water mains? 0 Yes 0 No ® NIA If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? > Please provide supplementary information identifying the areas of non-confonnance. • See the Division's draft r uir rnerrts for situations where separation cannot be met. > No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Cape Fear If yes, does the project comply with setbacks found in the river basin tiles per ! 5 A NC AC 0213.O2 012 > This includes Trout Buffered Screams per 1 S,_ NCAC 2B4O02 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits or 401 Water Quality Certifications? > Please provide the permit number/permitting status in the cover letter if coverage/authorization is req ❑ Yes ❑ No ® N/A ❑ No ® Yes ❑ No ® Yes ❑ No uired. 6. Does project comply with 15A NCAC 027.0I05(c d) (additional penmits/certifieations)? ® Yes ❑ No Per L = ' 13:,..11 t1 (c}i5 ), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance ofthis permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority? 0 Yes ® No Per t 5A NCAC 02T.0+02, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 1SA NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15,1 (; 02T, the MinimunrEkcAgoCriteria for shc_iaermiuing of Pimp Starr � gait (1.11M versionl, and the Gravity Scwt Minimum Design irjusri „ hgest versiorti) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. /4poroval of the request will be issued concurrently with the approval of the permit. and protects requiring a variance approval may be subiect to longer review times. For protects requiring two or more variances or where the variance is delermined by the Division to be a significant portion of the protect. the bit technical review is rennired. 2. Professional Engineer's Certification: I, Kirby R. Bel Jr, attest that this application for Arlington Meadows Phases 7-10 (Professional Engineer's name from Application Item 111.1.) (Project Name from Application Item 11.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and ati other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Olivia jam, .(ravily Sewers (lows! vers'roti), and the Minimum Drsrgn Criteria for Ilk Fast -Track I'tnnii i� of Pump Stationsi4 force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A statement, representation, or certification in any application include a fine not to exceed $10,000, as well as civil penalties information, including failure to disclose any design non the North Carolina -licensed Professional Engineer to referral and 143-215.6B, any person who knowingly makes any false package shall be guilty of a Class 2 misdemeanor, which may up to $25,000 per violation. Misrepresentation of the application -compliance with the applicable Rules and design criteria, may subject to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Michael Wagner , attest that this application for Arlington Meadows Phases 7-10 (Signature Authority Name from Application Item I.3.) (Project Name from Application Item 11.1) attest that this application has been reviewed by me and is accurate and complete to the beat of my knowledge. I understand that if all required parts of this application arc not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all requited parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143 2 r 5.13A and 141-2 i 5,6I3., any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: FORM: FTA 06-21 Date: 04/27/2022 Page 5 of 5 Itt.CDept of Environmental Quality Division of Wat••- AY Iit222 • Raleigh Regional office State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Town of Fuquay-Varina _ Project Name for which flow is being requested: Arlington Meadows Subdivision More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow, I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett Regional WWTP b. WWTP Facility Permit #: NC0021636 c. WWTP facility's permitted flow Fuquay-Varina Allocated Flow Lillington Allocated Flow Angier Allocated Flow d. Estimated obligated flow not yet tributary to the WWTP FV Obligated Flow NYT Lillington Obligated Flow NYT HC Obligated Flow NYT Angier Obligated Flow NYT e. WWTP facility's actual avg. flow FV Actual Flow Lillington Actual Flow HC Actual Flow Angier Actual Flow f. g• Total flow for this specific request Total actual and obligated flows to the facility FV Actual Avg. + Obligated Flow Lillington Actual Avg. + Obligated Flow HC Actual Avg. + Obligated Flow Angier Actual + Obligated Flow h. Percent of permitted flow used All flows are in MGD 7.5 MGD 2.60 MGD 1.20 MGD 1.008 MGD 2.504 MGD 0.655 MGD 0.237 MGD 0.965 MGD 0.647 MGD 5.087 MGD 1.231 MGD 0.642 MGD 2.568 MGD 0.646 MGD 0.020 MGD 7.611 MGD 1.906 MGD 0.879 MGD 3.533 MGD 1.293 MGD 101.48%* *A PER to expand the NHRWTTP treatment capacity has been completed and design of the expansion is currently underway. Page 1 of 4 FTSE 06-13 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)-(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm 1 pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** SLS 120 14.4 5.76 2.819 2.382 5.201 0.559 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < Q. Downstream Facility Name (Sewer): North Harnett Regional WWTP Downstream Permit Number: NC0021636 III. Certification Statement: I J T -c,i7L -bt)1.1'd certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and Il plus all attached planning assessment addendums for which l am the responsible party. Signature of this form indicates accept ce of this wastewater flow. 1 - )-3- Signing Official Signature Date Page 2 of 4 FTSE 06-13 DWR Division of Water Resources v ip lit Dept o1' linvironmental Quality rear I 1 2022 State of North Carolina Department of Environmental Quality Division of Water Resources Raleigh Region l p f cking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Town of Fuquay Varina Project Name for which flow is being requested: Arlington Meadows Phase 7-10 More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett Regional WWTP b. WWTP Facility Permit #: NC0021636 All flows are in MGD c. WWTP facility's permitted flow 2.6 d. Estimated obligated flow not yet tributary to the WWTP .655 e. WWTP facility's actual avg. flow 1.231 f. Total flow for this specific request .019 g. Total actual and obligated flows to the facility h. Percent of permitted flow used 1.886 72.5% 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station (Name or Permit Number) No. Gravity Firm Capacity, * MGD (A) Design Average Daily Flow** (Firm / pf), MGD (B) (C) (D)= (B+C) (E)=(A-D) Obligated, Approx. Not Yet Current Tributary Avg. Daily Daily Flow, Flow, MGD MGD Total Current Flow Plus Obligated Available Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): ToFV to KennethCreek/NeilsCreek Inter Downstream Permit Number: WQCS00193 to WQ0028647 Page 1 of 6 FTSE 10-18 Signing Official Signature III. Certification Statement: I Michael Wagner certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. /V /f/rt, Public Utilities Director Title of Signing Official Page 2 of 6 04/27/2022 Date FTSE 10-18 B N K Project Narrative: BASS, NIXON & KENNEDY, INC., CONSULTING ENGINEERS 6310 CHAPEL HILL ROAD, SUITE 250, RALEIGH, NC 27607 919/851-4422 FAX 919/851-8968 WWW.bnkinc.com Arlington Meadows Phases 7-10 The proposed Arlington Meadows Development is located at 1401 Angier Road, Fuquay-Varina, NC 27526. The site is approximately 3,200 LF south of the intersection of S. Judd Parkway SE and Angier Road. The ultimate project includes infrastructure construction for 172 Single Family Residential Units. The enclosed permits are for infrastructure construction associated with Phases 7-10 (81 units). The homes in Phases 7-10 will be served by 1,937 LF of 8" PVC, 2379 LF of 8" PVC-C900, and 239 LF of DIP sewer mains with a proposed flow of 19,950 GDP. A sanitary sewer outfall will be constructed within acquired easements through the Niels Crossing Subdivision and connect to a proposed sewer outfall currently under construction by the adjacent Geneva Subdivision. Please see enclosed Utility Plans. Attached Information: This package includes the following: 1. This Cover sheet with Narrative, Maps 2. FTA 06-21 (Instructions) 3. FTA 06-21 (Fast Track) 4. FSTE 10-18 5. FSTE 06-13 6. Existing Permit 7. $480.00 Check (#3291) Project Schedule: Construction of Arlington Meadows Phases 1-6 are complete and were previously permitted under WQ 0041329 dated December 20, 2019. Infrastructure construction for phases 7-10 is E s T 0 I n T Ids PROJ BND SCALE 1:24 000 0.5 0 KILOMETERS 1 1000 1{. 500 0 METERS 1 ;ppp MLES 1 _ , _ __go? - -- �-T 7000 SOW 9000 100p0 0.5 4P Auk FUQUAY-VARINA, NC ARLINGTON MEADOWS FUQUAY-VARNVA, WAKE COUNTY. NORTH CAROLINA SEWER PERMIT USGS QUAD 'FUQUAY-VARINA' THE SPAULDING GROUP, PA plaNnHnr rrc.ilengeneerina 16111 se &taigaR m a+ifrWIRAkgb NC27606 Ph as(919jSSI 7990 F rryt91854 7y1S 1000 2000 2016 REP T•y. •R: TRUE HOMES 2849 BREKONRIDGE CENTRE DR SUITE 104 MONROE. NC 28110 DATE : 11/21/2019 S&N FIRM CERT. j: C-1875 PROJECT ENGINEER: THOMAS J. SPAULDING PROJECT CADD DESIGNER: BD PROJECT SURVEYOR: ROBINSON & PLANTE, PLC co FUTURE SEWER (PHASE 7-10) �--- EXISTING SEWE (BY OTHERS) ARLING'PON MEADOWS FUGUAY-VARINA, WAKE COUNTY, NORTH CAROUNA SEWER PERMIT STREET LEVEL MAP AMBER FOREST DRIVE PROPOSED SEWER (PHASE 1-6) PREPARED FOR: TRUE HOMES 2649 BREKONRIDGE CENTRE OR SURE 104 MQNROE. NC 28110 DATE : 11/21/2019 PROJECT ENGINEER: THOMAS J. SPAULDING PROJECT CARD DESIGNER: BD PROPOSED SITE estimated to be complete by April 2023. Complete build -out of phases 7-10 and issuance of certificates of occupancy is expected to be complete by April 2024. Change of Engineer of Record: Please note that Arlington Meadows (Phases 1-10) was designed by Thomas Spaulding, PE with Spaulding & Norris, PA. The developer of record, True Homes USA decided to change project engineer for the remaining Phases 7-10 to Kirby R. Bell, Jr. PE with Bass, Nixon & Kennedy, Inc. Permission was granted by Thomas Spaulding to allow Bass, Nixon and Kennedy, Inc. to use plans designed by him. NC Dept of Environmental Quality MAY I 8 2a22 Raleigh Regional Office FAST TRACK SEWER REPORT ARLINGTON MEADOWS PHASES 7 - 10 FUQUAY-VARINA, NC Wake Co. Prepared by: Bass, Nixon & Kennedy, Inc. 6310 Chapel Hill Rd., Suite 250 Raleigh, NC 27607 May, 2022