HomeMy WebLinkAboutNCC213685_NOT Closeout Documents (5)_20220622w -w _w _w -
w -w
w �W
W �w �w
w W _
W w w
W W
oN
�w �W t
w / w
Ow
NO F- y��yO W w W
]HE S SS W \\ w w
E OHE E S
OHE SS S ONE Oy `'y0 W -4
❑HE E S SS p� F
HE OHE SS SS
OHE
- OHE SS SS SS Oy �yo w
HE OHE � SS 0 SS 'S =Li
OH � SS � \ •iy �
OHE OH SS �gy SS
c1s
OHE
50
F S � RIM ELEV.: 833.99
OHE OHE SS SS INV. OUT ELEV.: 828.67
II I I OH OH n, SS -, S
I
I
I
LEVEL GLOSS SURVEYING
WWI
2912 Kanay Road
Thomasville, NC 27360
(336) 495-1713
C14
TBC ELEV.: 830.26 _
JB3 INV. IN ELEV.: 825.19
GRATE ELEV.: 831.40 INV. OUT ELEV.: 825.13
INV. IN ELEV.: 826.32
INV. OUT ELEV.: 826.26
°
OH
C15
TBC ELEV.: 831.21
INV. IN ELEV.: 823.96
INV. OUT ELEV.: 823.89
I
D11 I U I
GRATE ELEV.: 830.93 CB2
INV. OUT ELEV.: 827.43 GRATE ELEV.: 830.52
INV. IN ELEV.: 826.99
INV. OUT ELEV.: 826.92
STORM C.O. ° C/)
STORM C.O. CAP ELEV.: 831.37 U)
CAP ELEV.: 830.69
STORM C.O.
CAP ELEV.: 831.00
_ � x
STORM C.O. L� w
CAP ELEV.: 830.52
LEGEND
CATCH BASIN (CB)
CURB INLET (CI)
JUNCTION BOX (JB)
DROP INLET (DI)
O
STORM MANHOLE
O
STORM CLEANOUT (C.O.)
FLARED END STRUCTURE (FES)
STORM SEWER PIPE
TBC
TOP OF BACK OF CURB
STORM C.O.
CAP ELEV.: 830.71
SHEET NOTES:
1. PLAT BASED ON FIELD SURVEY CONDUCTED 11/19/2020 BY LEVEL CROSS
SURVEYING, UNDER THE RESPONSIBLE CHARGE OF WILLIAM S. DURHAM, JR, P.L.S.
2. UNDERGROUND WATERLINE LOCATIONS AND REMAINING FEATURES NOT
SPECIFICALLY NOTED ARE ASSUMED BASED ON SITE PLAN DRAWINGS AND
SURVEYED SURFACE FEATURES.
3. BUILDINGS, PARKING, AND OTHER UNDERLYING FEATURES SHOWN HEREON
REPRESENT THE SITE PLAN SET "AUTOZONE STORE #5992" BY BERRY ENGINEERS
LLC" DATED 05/29/2020. ACTUAL LOCATIONS MAY VARY.
4. STRUCTURE ELEVATIONS GIVEN AT SURFACE ELEVATION AT CENTERLINE OF
STRUCTURE.
S
o0
O
❑HE H SS
OHE
OHE OHE OHE O6H
EW7
INV. ELEV.: 823.67 I
I
I RISER
I TOP ELEV.: 828.42
WEIR ELEV.: 827.21 I
ORIFICE ELEV.: 825.01
- - INV. OUT ELEV.: 824.10
EW12
INV. ELEV.: 822.86
I, WILLIAM S. DURHAM, JR., AS A DULY REGISTERED PROFESSIONAL LAND SURVEYOR IN
THE STATE OF NORTH CAROLINA, HEREBY CERTIFY THAT THE DATA SHOWN ON THIS
DRAWING, OBTAINED UNDER MY SUPERVISION, IS AN ACCURATE AND COMPLETE
REPRESENTATION OF WHAT WAS CONSTRUCTED IN THE FIELD, THAT THE PHYSICAL
DIMENSIONS OR ELEVATIONS SHOWN THUS ARE AS -BUILT CONDITIONS AND THE FACILITY
WAS CONSTRUCTED ACCORDING TO THE APPROVED PLANS, EXCEPT OTHERWISE NOTED
HEREON.
�t CAROB
? : QO*Essto,q,�`
sQ t
SEAS- s `+ NAME:
.,� M S
12/10/2020
DATE:
OHE - OHE
JB9
GRATE ELEV.: 833.17
INV. IN ELEV.: 827.87
INV. OUT ELEV.: 827.91
STORM MH10
RIM ELEV.: 828.65
INV. IN ELEV.: 823.48
INV. IN ELEV.: 823.47
INV. OUT ELEV.: 823.52
STORM MH11
RIM ELEV.: 827.58
INV. IN ELEV.: 822.93
INV. OUT ELEV.: 822.88
N
l
TNC GRID
NAD 83/2011
AS -BUILT PLAT
STORM SEWERAGE SYSTEM
AUTOZON E #5992
GREENSBORO
NORTH CAROLINA
0 10 20 40 60
SCALE: 1" = 20'
DRAWING PREPARED: 12/05/2020