Loading...
HomeMy WebLinkAboutNCC213685_NOT Closeout Documents (3)_20220622\ -- - - - - - - !-I I - - - - - - - - - - - - - - - - - •� HICONE RD JUNCTION BOX (#3) TOP=831.42 INV. IN=826.32 INV. OUT=826.26 (PRIVATE) 75' 18"0 HDPE CURB INLET (#4) THROAT=829.76 INV. IN=825.19 . - - INV. OUT=825.13 - 83: (PRIVATE) _ _ Y SLOPE=0.80% 00 � � I 832 / / 48' 18"0 HDPE I/ SLOPE=0.92% DROP INLET (#1) THROAT=830.93 / I INV. OUT=827.43 (PRIVATE) I i i 47' 18"0 HDPE SLOPE=2.28% . . / 142' 18"0 HDPE _ SLOPE=0.82% bi E) 56' 18"0 HDPE SLOPE=0.36% CURB INLET (#5) THROAT=830.71 INV. IN=823.96 INV. OUT=823.89 (PRIVATE) 831 / / 832 \ / ENDWALL (#7) k INV.=823.67 (PRIVATE) 828 824 CURB INLET (#6) I l THROAT=830.65 831 INV. IN=823.69 / / INV. OUT=823.62 (PRIVATE) - 26' 18"0 HDPE AUTOZOfVE / SLOPE=0.00% Lc.I 824 CATCH BASIN (j2) F.F.E.=832.00 _ TOP-830.52 o / N 826 INV. IN=826.99 i / i INV. OUT=826.92 / 828 (PRIVATE) 1 i / ` 828 / C.O. iC.O. 832 _ i �� i _ 830 826 - - 824 826 _ 150' 8"0 PVC / --� SLOPE=1.0% STORM PLAN (ONSITE) 838 836 834 832 830 828 826 824 822 820 818 816 814 812 8104, SCALE: 1 " = 30' HORIZONTAL Z m ZQ>� m M N .N Z O0 � IIOWH OQ 2 > U Q ?� U N cn cnto c0 00 m 00 11 � W O� Z ZOQ H II - > U jj� Z ??� � W MN O m� ZOQ II - > m »� j -- U �N 00 00 11 � 11� ?OQ > m >j0=jj� zza U En to 00O �mvi M 00 m II�W Z � Q?OQ > m 0=jj0_ ??� U N cn to (flN n M 00 qh 00 11 m II W� JO OW Q?OQ Q Q 0> 3 II > Zj0_ CL ??� uj F NISHED GRAD FINISHED GRADE _ TAIL ATER=827.30 48 18"0 H PE - SLOPE=0,8 7' 1800 HDPE 8"0 ROOF DRAIN = •28% INV.=828.0 18 "0 00011WIV-Off PONE) _92.3.50 ° LOPE=0.00 Q10=3.5 CFS 10=5.1 CFS Q10 6.3 CFS Q10 7.3 CFS 10=7.6 CFS 1+00 0+00 1_00 3+00 2+00 STORM PROFILE (ONSITE) SCALE: 1 " = 30' HORIZONTAL 1 " = 6' VERTICAL (5x) DRAINAGE AREA COMPUTATIONS - PROPOSED DRAINAGE AREA RUNOFF COEFFICIENT (C) AREA (ACRES) TIME OF CONCENTRATION (MIN) INTENSITY 10 YEAR (IN/HR) DISCHARGE 10 YEAR (CFS) COMMENTS Al 0.8 0.79 10 5.5 3.5 To Area Drain (#1) (Lot 1 Drainage) A2 0.8 0.17 10 5.5 0.8 Roof Drains A3 0.8 0.19 10 5.5 0.8 To Catch Basin (#2) A4 0.8 0.26 10 5.5 1.2 To Curb Inlet (#3) A5 1 0.8 0.23 10 1 5.5 1.0 To Curb Inlet (#4) A6 0.8 0.06 10 5.5 0.3 To Curb Inlet (#5) A7 0.8 0.24 10 5.5 1.1 Detention / Sand Filter Area TOTAL BMP AREA = 1.9 DISCHARGE TO BMP = 8.6 B1 0.6 1.20 15 4.6 3.3 Off -Site Drainage (Cross -Drain) B2 0.8 0.32 10 5.5 1.4 To Proposed Road Inlet B3 0.8 0.18 10 5.5 0.8 To Existing Road Inlet TOTAL ROAD AREA = 1.7 OFF -SITE DISCHARGE = 5.6 Cl 1 0.3 0.51 10 1 5.5 0.8 On -Site Buffers, Sheet Flow, Bypasses BMP TOTAL BYPASS AREA = 0.5 SHEET FLOW / BYPASS = 0.8 111 I I � I / II EX. INLET I I / STORM MANHOLE (#9) / COG #400 STORM MANHOLE (#10) 1 - - ( I I TOP=833.17 COG #400- / I 15" INV. IN=827.87 _ - - - - - - - - TOP=828.65 \I I I I I I 24" INV. OUT=827.91 INV. IN=823.47 - STORM MANHOLE (#11)fill - - 1 (PUBLIC) INV. OUT=823.52 COG #400 (PRIVATE) _ TOP=827.58 INV. IN=822.93 / INV. OUT=822.88 / (PRIVATE) / 0 / I / 3024"0 RCP I I I EX. ENDWALL 107' 24"0 RCP / I SLOPE=0.00% SLOPE=4.15% ark C 46' 24"0 RCP I I SLOPE=1.28% Q I / O In 0 ENDWALL / INV.=822.86 CDco 3 - 4 / co co I (PRIVATE) 1 11I I I I ---- -� I I LEVEL SPREADER TOP ELEV.=823.5 0 ( (I II I / / (PRIVATE) I I I I UGoI I J 1 � \ \ I I 1 15' 15' 0 RCP U I I I SLOPE=0.70% 00 P/III I LLJ II �, U CURB INLET (#8) I w COG #402 ] � THROAT=833.49 I �p 15" INV.=828.67 r I \ \ \ \ \ I (PUBLIC)03 - �` 838 838 836 836 834 834 832 832 830 830 828 828 826 826 824 824 822 822 820 820 818 818 816 816 814 814 812 812 810 810 AS -BUILT \\\ \ 00 i1111 1,1iI I\ ,oK N \ I I I c(lI II 111 I \ STORM PLAN (OFF -SITE) SCALE: 1 " = 30' HORIZONTAL 00 J 0_C90_: n0= UUH�� rl °) 00 N W O M O Z mO zh�OEOM m 00a: m (~/1U��N� ^ rn co I,� W 00 II O r- II O Z �0QmII M Z Zp : m 0UajjQ �U�ZZv N W �M O ulM� Z O� � co II � q60Z0 g�a0Z0m 00ajjY �U0ZZv CIO _ OMiN N OON0 to ��CO 00II II�� �� J N N� QQ00aQ 05W wZa FINISHED 7GTZADlE­ HGL10 HGL - ° 10 , SLOP 0 RC - (P(/ $ 24 RCP 11 24"0 RC SLOPE_1.287. LOPE=0.007. 10=1.4 CFS Q10 5.5 CFS Q10 8.9 CFS Q10=8.9 CH 3+00 2+00 1+00 STORM PROFILE (OFF -SITE SCALE: 1 " = 30' HORIZONTAL 1 " = 6' VERTICAL (5x) HYDRAULIC COMPUTATION FOR STORM DRAINS FROM TO DISTANCEz W 0 Ln a J ui Wuj L 0� O = ( W ¢ a "' W W a W C- o , Q n W , F ILL `z ,0 J_ HYDRAULIC GRADIENT VELOCITY MINOR LOSSES N PAaRIS�>O UPSTREAM ELEVATION DOWNSTREAM0 ELEVATION z > D o a o= Z W Ja o= uw 0 ,, ow am uj 0 v to o� Z Q< aJ 0HPGLCOzQ>M I - zo a O V) cr w kD w zs au O wz w> (FT) CFS CFS CFS INCHES S.F. FT/FT FT/FT FT FT/S FT/S FT FT #1 #2 48 3.5 0.0 3.5 18 1.77 0.009 0.0012 0.06 829.09 829.03 0.0 2.0 0.00 0.06 1.25 0.06 0.12 830.93 1.84 #2 #3 75 0.8 4.3 5.1 18 1.77 0.008 0.0022 0.17 828.95 828.78 2.4 2.9 0.09 0.13 0.50 0.08 0.25 830.52 1.57 #3 #4 47 0.0 5.1 5.1 18 1.77 0.023 0.0022 0.10 828.72 828.61 2.9 2.9 0.13 0.13 0.50 0.06 0.17 831.40 1 2.68 #4 #5 132 1.2 5.1 6.3 18 1.77 0.008 0.0035 0.46 828.48 828.02 2.9 3.6 0.13 0.20 0.50 0.13 0.59 829.76 1.28 #5 #6 56 1.0 6.3 7.3 18 1.77 0.004 0.0048 0.27 827.85 827.58 3.6 4.1 0.20 0.26 0.50 0.17 0.44 830.71 2.86 #6 1 #7 1 26 1 0.3 1 7.3 1 7.6 18 1 1.77 1 0.000 0.0050 1 0.13 1 827.43 1 827.30 1 4.1 4.3 0.26 1 0.29 0.50 0.15 0.28 830.65 3.22 #8 #9 115 1.4 0.0 1.4 15 1.23 0.007 0.0010 0.12 829.09 828.97 0.0 1.1 0.00 0.02 0.50 0.02 0.14 833.49 4.40 #9 #10 107 0.0 5.6 5.6 24 3.14 0.042 0.0010 0.11 828.95 824.81 1.8 1.8 0.05 0.05 0.50 0.02 0.13 833.17 4.22 #10 #11 46 0.0 10.0 10.0 24 3.14 0.013 0.0020 0.09 824.73 824.64 3.2 3.2 0.16 0.16 0.50 0.08 0.17 828.65 3.92 #11 #12 30 0.0 10.0 10.0 24 3.14 0.000 0.0020 0.06 824.56 824.50 3.2 3.2 0.16 0.16 0.50 0.08 0.14 827.58 3.02 0+00 ENCROACHMENT PERMITS REQUIRED THROUGH NCDOT FOR SIDEWALK, STORM SEWER, WATER, AND SANITARY SEWER. CALL 336-487-0100 FOR PERMIT. 838 836 834 832 830 828 826 824 822 820 818 816 814 812 810 STORM SEWER INSPECTION: PRIOR TO PUBLIC STORM SEWER INSTALLATION, CONTACT ANDY VINCENT AT 363-373-2336 TO SCHEDULE INSPECTOR. AFTER FINAL TRC APPROVAL, SUBMIT ONE SET OF PLANS TO THE ENGINEERING DEPT FOR RECORD PURPOSES. PLEASE CALL 336-373-2052 WITH ANY QUESTIONS. NOTE: ALL CONSTRUCTION TO MEET CITY OF GREENSBORO AND NCDENR STANDARDS. ALL PUBLIC STORM SEWERS MUST BE INSTALLED PER NCDOT SPECIFICATIONS. GRATE I NLET CAPACITY CHECK INLETTYPE: NEENAH R-1878-A9G (30"X30") INLETOPEN AREA: 2.5SQ. FEET MAXIMUM ALLOWABLE PONDING: 0.5' ASSUME 50% CAPACITY DUE TO CLOGGING USING WEIR FLOW FOR DEPTHS OF 0.5' OR LESS [Q=3.0*P*d^0.5] 10-YEAR INLET FLOW INLET CAPACITY CATCH BASIN, A2 0.8 CFS 5.2 CFS CURB INLET, A3 0.3 CFS 4.0 CFS CURB INLET, A4 1.2 CFS 4.0 CFS CURB INLET, A5 1.0 CFS 4.0 CFS DI u 0 0c a 0c 0c i W un H w rA v♦ U a �iW W w �� �j a zm �MEMO z w W z W z C7 w Wa Ln> W W m U W � W U Q O w � 0 Q 00 M Z w Z � M w �a, O a > w � r� I4 I4 ('� v J 'c) O O V J N wwQ v) Z .�' CA FEss SEAL 39998 ®ip FNG I !SS9� . • Z", REVISIONS 1 2 3 4 5 6 7 8 9 10 SHEET NAME: DRAINAGE PROFILE DATE: 05/04/2021 DRAWN BY: CMB CHECKED BY: BMB PROJECT NO.: 19066 SHEET NUMBER: C2.2 1/IATCrf T. IT -Al PERFORATED PVC PIPE E AND AreliI2 SAND FILTER UNDERDRAIN CLEANOUT DETAIL N.T.S. NOTE: IF SEDIMENT PRETREATMENT CHAMBER ACCUMULATES TO ELEVATION 824.50, THEN THE FOREBAY SHALL BE CLEANED OUT AND RETURNED TO ITS DESIGN STATE. WATER QUALITY VOLUME REQUIRED=3,658 CF WATER QUALITY VOLUME PROVIDED=4,500 CF RIP RAP BERM 5' RIP RAP SPLASH AREA _WQV ELEV=829.00 I 0 LTER BED OUTFLOW SAND FILTER CROSS SECTION 1 o' OVERFLOW SPILLWAY 77f7� SEE DETAIL THIS SHEET FOR REQUIRED KEY TRENCH & FILTER DIAPHRAGM SEE PLAN VIEW FOR CONTINUATION. WATER QUALITY UNDERDRAIN FLOWS TO PUMP BASIN FOR DISCHARGE. W, 36"x36" GRATE IN TOP SLAB 6" OVERFLOW WEIR OPENING CORNER SUPPORTS (TYP. 4 SIDES) (TYP. ALL CORNERS) 4. d. d ' d d. d� .e d Q. d d p d r d O a ELEV.=827.2 ELEV.=827.2 ° 61, d ELEV.=826.5 d a 4' SQ. d. 9" 0 ORIFICE 9" 0 ORIFICE----_ INV.=825.0 INV.=825.0 e a a.' d VWQV=3,700 C.F. / _ e \ 18" HDPE d. = d 1 d• INV.=824.1 -q d d a a BOTTOM OF POND d .e d ° •e e'e < ELEV=823.0 A. A a e 4• d' id u d • e a' a 8" SIDE VIEW FRONT VIEW OUTLET CONTROL STRUCTURE N.T.S. E RII 7 r.e Nw/ \��l IT��TTI.ITJ PROFILE VIEW SECTION VIEW ELEV.=827.0 O II-IILY\ I.VI umr-IG CONCRETE EMERGENCY SPILLWAY N.T.S. AS —BUILT ENGINEER'S CERTIFICATION: THE STORMWATER CONTROL STRUCTURE(S) SHOWN ON THIS PLAN ARE DESIGNED TO REDUCE THE PEAK FLOW RATES IN THE POST -DEVELOPMENT 1-YEAR, 2-YEAR, AND 10-YEAR, 24-HOUR STORM EVENTS TO PRE -DEVELOPMENT PEAK FLOW RATES. CHRISTOPHER M. BERRY NC PE #39998 ENGINEER'S CERTIFICATION OF STORMWATER QUALITY CONTROL: I CERTIFY THAT, PURSUANT TO GENERALLY ACCEPTED ENGINEERING STANDARDS IN THE COMMUNITY, IT IS MY PROFESSIONAL OPINION THAT RUNOFF FROM THE FIRST INCH OF RAINFALL FROM AREAS THAT ARE REQUIRED TO BE CONTROLLED PER 30-12-3.12 OF THE GREENSBORO LAND DEVELOPMENT ORDINANCE IS CONTROLLED BY A PERMANENT ENGINEERED STORMWATER QUALITY CONTROL THAT HAS BEEN DESIGNED TO MEET OR EXCEED THE REQUIREMENTS IN THE GREENSBORO STORMWATER MANAGEMENT MANUAL. CHRISTOPHER M. BERRY NC PE #39998 ENGINEER'S STATEMENT OF POND AND DAM SAFETY NOTE: IN ACCORDANCE WITH THE REQUIREMENTS IN ARTICLES G5 143-215.25A AND 143-215.26 OF THE NC DAM SAFETY LAW AND NC ADMINISTRATIVE CODE 15A NCAC 2K.0200, THE REGIONAL ENGINEER IN THE WINSTON-SALEM REGIONAL OFFICE WILL BE CONTACTED FOR THE DETERMINATION OF WHETHER THE PROPOSED DAM IS GOVERNED BY OR EXEMPT FROM THE DAM SAFETY LAW. CITY OF GREENSBORO REQUIREMENTS FOR 'FINAL C.O.' #1 - SUBMIT COPY OF RECORDED OPERATION & MAINTENANCE AGREEMENT AGREEMENT MUST REFERENCE OPERATION & MAINTENANCE PLAN FOR SCM #2 - SUBMIT COPY OF RECORDED EASEMENT PLAT PLAT MUST REFERENCE OPERATION & MAINTENANCE PLAN FOR SCM #3 - SUBMIT SIGNED & SEALED ENGINEERS CERTIFICATION #4 - SUBMIT SURVEYED 'AS -BUILT' OF SCM #5 - FINAL INSPECTION TO BE PERFORMED BY CITY WATER RESOURCES DEPARTMENT 2 4 S TOTAL LAND AREA 2.35 ACRES BUILT UPON AREA TO BMP 1.38 ACRES 59% LOT 1 TOTAL AREA - BOJANGLES 1.10 ACRES BUILT -UPON AREA (TO BMP) 0.72 AC 31% LANDSCAPE AREA (TO BMP) 0.23 AC 10% LANDSCAPE AREA (BYPASS) 0.15 AC 6% LOT 2 TOTAL AREA - AUTOZONE 1.25 ACRES BUILT -UPON AREA (TO BMP) 0.66 AC 28% LANDSCAPE AREA (TO BMP) 0.49 AC 21 % LANDSCAPE AREA (BYPASS) 0.10 AC 4% .1" ".... PRO ILL VIEW PIPE TRENCH SECTION VIEW 18"0 HDPE 4"0 SCH 40 PVC OUTLET FILTER DIAPHRAGM N.T.S. 0 0 0c 0c 0 C�0c � CA W un H w HI r o a Lu w �iW r W �� a m ICI r z z H Q w Z W z �z Z w �W W m U W � a U Q C w O Q p� OHO M � Z w Z O � p O T--a M w � a o � a > w � Q u z �C�) ^^ll wwc N wwQ C�� Qwo �C/) o� .�' CA FESS SEAL 39998 ® 2®Z-•�,= NS REVISIONS 1 BULLETIN #1 06/08/20 2 3 4 5 6 7 8 9 10 SHEET NAME: DETAILS DATE: 05/04/2021 DRAWN BY: CMB CHECKED BY: BMB PROJECT NO.: 19066 SHEET NUMBER: C2.3 12'- 2 v v v�s, v L, I�II�IjI�I • : 1 " DIA. WEEPHOLE (4 REQ'D.) PRE -CAST STRUCTURE PER DOT HEAVY DUTY TRAFFIC RATING. ROUND PRECAST Cf BE SUBSTITUTED FOR SQUAI CATCH BASIN N.T.S. SITE GRADING/STORM CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE OF ALL CATCH BASINS DURING CONSTRUCTION. ELEVATION M I RAFI 140N NON -WOVEN FILTER FABRIC OR EQUAL (TYPICAL) CAST -IN -PLACE CONCRETE INVERT 6" THICK WASHED STONE (TYP) 3 NOTE: VERIFY ALL INLET/OUTLET ORIENTATIONS PRIOR TO FABRICATION NOTE: VERIFY ALL ELEVATIONS PRIOR TO FABRICATION 6" OPENING ON ALL 18" APRON MIN SIDES OF STRUCTURE 36" CAST IRON GRATE (TYPICAL) WITH POSTS AT EACH CORNER MIN 6" THICK CONCRETE APRON WITH 6x6 10/10 ❑❑❑❑❑❑❑❑❑❑❑ WWF SLOPE 1/2" THROAT ELEV. III=III=1 X .. — a II- N -I 1= o rl 4' MIN. WASHED STONE g" ALL AROUND ^ ^� 1" DIA. WEEPHOLE (4 REQ'D.) PRE -CAST STRUCTURE PER DOT HEAVY DUTY TRAFFIC RATING. ROUND PRECAST CI BE SUBSTITUTED FOR SQUAI (APRON STILL REQUIRED ON ROUND STRUCTURE, TOP RISER SHALL BE RAISED TO ACCOMMODATE APRON THICKNESS) =M DESIGNED TO RUN 1 PUMP TIME (ALTERNATING STARTS) .S: NTROLS SHALL BE MOUNTED INSIDE A UL LISTED ENCLOSURE AND INCLUDE CIRCUIT BREAKERS, RCUIT FUSE, IEC RATED MOTOR STARTER, PUMP 1 ALTERNATOR RELAY. PANEL SHALL HAVE A LARM BEACON. PANEL IS DESIGNED FOR REMOTE i. M HATCH: RATED, 1/4" ALUMINIUM SKID -RESISTANT ATE, STAINLESS STEEL TAMPERPROOF & HINGES do SLAMLOCK. (H-20 RATING PUMP No. TYPE GPM TDH RPM ELECTRICAL HP V PH Hz P-1 CARRY 30 20' .5 120 1 50 P-2 CARRY 30 20' .5 1 120 1 1 1 50 STORM PUMP DETAIL N.T.S. IT; , N.T.S. SITE GRADING/STORM CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE OF ALL CATCH BASINS DURING CONSTRUCTION. NO. 4 BARS M I RAFI 140N NON -WOVEN FILTER FABRIC OR EQUAL (TYPICAL) CAST -IN -PLACE CONCRETE INVERT 6" THICK WASHED STONE (TYP) KEYED NOTES MARK OTY DESCRIPTION 1 2 30 GPM, 1/2 HP SUBMERSIBLE PUMP 2 2 STAINLESS STEEL CHAINS 3 1 DUPLEX CONTROL PANEL NEMA 4X FRP w/ GENERATOR RECEPTACLE (MOUNTED & WIRED BY CONTRACTOR) 5 2 3" ELECTRICAL COUPLING 6 1 SS CABLE BRACKET 7 1 36" INSIDE DIAMETER WET HELL - "CONCRETE OR FIBERGLASS ACCEPTABLE 9 1 36"x60" DOUBLE LEAF ALUMINUM HATCHWAY 10 1 SAFETY NET 12 2 1.W SCH 80 PVC DISCHARGE PIPE 13 2 1.25" SCH 80 PVC 90' ELL 14 2 1.2V CHECK VALVE 15 3 FLOAT SWITCH 45' OF 1.5" FM _ JT II FLOW �_u 0 NEENAH R-3246 VULCAN V-4060-1 EAST JORDAN 703OM2 US FOUNDRY 5130-6168 N o�\ PIPES MIRAFI 140N -III-I I II I �I I I� NON -WOVEN FILTER Pip'l I FABRIC OR EQUAL WASHED STONE DIA. WEEPHOLE R EQ' D. T-IN-PLACE CRETE INVERT 6" THICK WASHED STONE (TYP.) CURB INLET WITH GRATE N.T.S. PRE -CAST CATCH BASIN, TRAFFIC RATING. SITE GRADING/STORM CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE OF ALL CATCH BASINS DURING CONSTRUCTION. 6"0 RIPRAP 12" THICK I GEOTEXTILE ' I: FABRIC ELEV.=822.9 ELEV.=823.5 6"0 GROUTED RIPRAP 4a° a a a a a I� 36" �l LEVEL SPREADER DETAIL N.T.S. - GEOTEXTILE FABRIC 7 0 CONSTRUCTION AS —BUILT RIP -RAP CONCRETE ENDWALL DETAIL N.T.S. RIP -RAP O oc oc 0 C�oc � r- CA oc W un H w lun r a ww O �i r W �� a z � m m � ICI r z z H Q w Z W z �� Z z w W �W �. W m U W � a U Q w C) Q 00 M C� w 0 r--a M w � a O a w Q ^^ll '0) O VJ � O N w wwQ w ow C�� (�� Qwo �C/) r0r l f, U ~ xj W ti O a FESS SEAL 39998 ® 20 Z• 4k . ®� �'FNGINE��'•• , . REVISIONS 1 2 3 4 5 6 7 8 9 10 SHEET NAME: DETAILS DATE: 05/04/2021 DRAWN BY: CMB CHECKED BY: BMB PROJECT NO.: 19066 SHEET NUMBER: C2.4