Loading...
HomeMy WebLinkAboutNCC213685_NOT Closeout Documents (2)_20220622Sand Filter On Record of Construction Engineer's Certification of Completion GREENSBORO Project: AutoZone - 4626 Hicone Rd Water Resources Department Stormwater Management Division 2602 S. Elm -Eugene St. Greensboro, NC 27406 (336) 373-2055 Date: 5/3/2021 Description Design As -built I Sand Filter Type Open -Bottom Open -Bottom 2 Sediment Chamber Specifications: a Sediment Chamber bottom elevation 823.50 823.0 b Sediment Chamber depth 1.5' (WQv) 2.0' (WQv) c Sediment Chamber surface area (ft) 1,000 sf 1,100 sf d Sediment Chamber volume (ft) 1,665 cf WQv 2,300 cf WQv 3 Sand Filter Chamber Specifications: a Elevation at top of filter media 823.50 823.2 b Depth of filter media 1.25' 1.3' c Filter bed area 1,250 sf 1,200 sf d Volume 2,035 cf (WQv) 2,200 cf (WQv) e Type & size of filter media 3" Depth River Stone 12" Depth Washed Sand 3" Depth River Stone 12" Depth Washed Sand 4 Percent of water quality volume stored in sediment chamber & facility 45% 55% 51 % 49% 5 Underdrain System Specifications: a Size & type of perforated pipe 4" PVC 4" PVC b Type (of stone) and thickness of filters around perforated pipe 9" #57 Stone 9" #57 Stone c Number of branch lines 2 2 d Invert elevation of underdrain 821.50 821.3 e Invert elevation of outflow pipe at outlet 821.00 (Storm Pump) 824.00 (OCS, 18" Out) 820.9 (Storm Pump) 824.1 (OCS, 18" Out) f Invert elevation of receiving storm sewer / receiving stream water surface 823.50 (M.H. #10) 823.5 (M.H. #10) g Depth of gravel jacket 6" 6" 6 Invert elevation of overflow / bypass structure 826.50 & 827.50 826.2 & 827.2 7 Dissipator pad length & width 70' Level spreader; 824.00 70' level spreader; 823.5 8 Maintenance access provided (Yes / No) Yes Yes Sand Filter Record of Construction L%0& Engineer's Certification of Completion GREENSBORO Water Resources Department Stormwater Management Division 2602 S. Elm -Eugene St. Greensboro, NC 27406 (336) 373-2055 ENGINEER'S CERTIFICATION OF STORMWATER CONTROL COMPLETION I certify that, pursuant to generally accepted engineering standards in the community, it is my professional opinion that the stormwater control(s) labeled as Sand Filter on this plat (or on name of plat) as recorded in PB 203 , PG 76 in the Office of the Guilford County Register of Deeds has been completed in conformance with the plans and specifications approved on 06/04/2020 , has its full design volume available, and is functioning as designed. P.E. SEAL: SIGNATURE: DATE: