HomeMy WebLinkAboutNCC222221_Site Plan or Location Map_20220624VICINITY MAP N.T.S.
Sheet List Table
ORIGINAL
ISSUE DATE
REVISION
DATE
REVISION
NUMBER
SHEET NO.
SHEET TITLE
C1.0
COVER SHEET
1111812021
0411912022
C
C1.1
NOTES
1111812021
0411912022
C
C1.2
NCDEQ NOTES
1111812021
0411912022
C
C2.0
EXISTING CONDITIONS AND DEMOLITION PLAN
1111812021
0411912022
C
C3.0
SITE PLAN
1111812021
0411912022
C
C4.0
EROSION CONTROL PLAN STAGE 1
1111812021
0411912022
C
C5.0
EROSION CONTROL PLAN STAGE 2
1111812021
0411912022
C
C6.0
GRADING AND DRAINAGE PLAN
1111812021
0411912022
C
C7.0
UTILITY PLAN
1111812021
0411912022
C
C8.0
LANDSCAPE PLAN
1111812021
0411912022
C
C9.0
SITE DETAILS
1111812021
0411912022
C
C9.1
SITE DETAILS
1111812021
0411912022
C
C10.0
EROSION CONTROL DETAILS
1111812021
0411912022
C
C10.1
EROSION CONTROL DETAILS
1111812021
0411912022
C
C10.2
EROSION CONTROL DETAILS
1111812021
0411912022
C
C11.0
GRADING AND DRAINAGE DETAILS
1111812021
0411912022
C
C11.1
GRADING AND DRAINAGE DETAILS
1111812021
0411912022
C
C12.0
UTILITY DETAILS
1111812021
0411912022
C
C12.1
UTILITY DETAILS
1111812021
0411912022
C
C13.0
SCM DETAILS
1111812021
0411912022
C
C14.0
LANDSCAPE DETAILS
1111812021
0411912022
C
SURVEY
Detention pond and water
easement plat & deed will need to
be recorded before the issuance
of CO. As-builts and certifications
will also be required before the
issuance of CO.
All construction to conform to City of
Gastonia Standards and Specifications
BEFORE YOU DIG
STOP
CALL 1-800-632-4949
NC ONE CALL CENTER
IT'S THE LAW,
43.
Know what's below.
Call before you dig.
Water and sewer taps to be
installed by the developers
contractor.
PLANNING DEPARTMENT APPROVAL
Date: 05/13/2022
Signature: %�� �%�
This site plan is valid for a period of 6 months from
the date above.
Engineering Approval
Date: 05/17/2022
Signature: 70c4m 4, %Q avt
Assistant City Engineer
Authorization to Construct
City of Gastonia
Local Water/Sewer Approval Program
05/17/2022
Permits: 202100482-S
Approved: 74c4n,4. Ld�&w
Authorization to construct is not valid
until pre -construction meeting has
been held with City of Gastonia staff.
DELTA DRIVE
SELF -STORAGE FACILITY
PERMIT REVIEW DRAWINGS
CITY OF GASTONIA FILE #202100261
- --R/W RM --RM --R/W- RM --RM--R/W-- RM --RM--R/W-- R/W-- --RM
DEL T,4 DO/l/O — 00 ' OOOL/C R,401
V,4P 900W 59, P,4CE 110
&,90 000/< 8V, 1,0146E 6'6
now
00
Exponential
OVERALL SITE
60' 0 60' 120'
SCALE: 1 "=60' (Horiz.)
1651 DELTA DRIVE
CITY OF GASTONIA
GASTON COUNTY, NC
APRIL 2022
70(
0
AD
OWNER/DEVELOPER
NAME:
DELTA DRIVE II, LLC.
BRANDON MAXWELL
ADDRESS:
101 N. TRYON ST. #629
CHARLOTTE, NC 28246
PHONE #:
704-825-8286
EMAIL:
BRANDON@EXPONENTIAL-EQUITY.COM
SITE STATISTICS
PARCEL #:
SITE AREA:
TREE SAVE AREA:
ZONING:
WATERSHED:
EXISTING LAND USE:
PROPOSED LAND USE:
PROPOSED IMPERVIOUS AREA:
MINIMUM SETBACKS:
FRONT
SIDE
REAR
FEMA MAP NUMBER:
FEMA MAP DATE :
STORMWATER NOTES:
224357
±5.89 ACRES
0.89 ACRE
C-3 (CD) (REZONING NUMBER 202100261)
CROWDERS CREEK
VACANT
SELF -STORAGE
94,000 SF
50'
20'
30'
3710353600J
09/28/2007
- MAXIMUM INTERNAL VELOCITY IN RCP SYSTEMS SHALL BE 20 FT/SEC.
- THE FIELD INSPECTOR, WITH APPROVAL FROM THE CITY ENGINEER, SHALL HAVE THE AUTHORITY TO
REQUIRE ADDITIONAL RIP -RAP ALONG DRAINAGE AREAS WHERE WARRANTED BY POSSIBLE EROSION OR
WHERE DRAINAGE AREAS CROSS OTHER UTILITIES.
- THE FIELD INSPECTOR, WITH APPROVAL FROM THE CITY ENGINEER, SHALL HAVE THE AUTHORITY TO
REQUIRE EXTENSIONS FROM THE PROPOSED STORM DRAINAGE SYSTEMS WHERE FIELD CONDITIONS SO
WARRANT.
- STORM DRAINAGE SYSTEMS SHALL BE DESIGNED TO TERMINATE SO AS NOT TO REQUIRE TAIL DITCHES
WITHIN THE 100 YEAR FLOOD PLAIN AREA. IF EXTENUATING CIRCUMSTANCES EXIST, ANY TAIL DITCHING
WITHIN THE 100 YEAR FLOOD PLAIN SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO
CONSTRUCTION.
- OPEN DRAINAGE SYSTEMS RECEIVING GREATER THAN ONE (1) ACRE OF DRAINAGE AREA SHALL NOT BE
ALLOWED TO DISCHARGE OVER THE STREET CURB WITHOUT A STORM DRAINAGE SYSTEM DESIGNED IN
ACCORDANCE WITH CITY STANDARDS AND SPECIFICATIONS. OPEN DRAINAGE SYSTEMS OF GREATER
THAN ONE (1) ACRE OF DRAINAGE AREA SHALL BE PIPED WITH STORM DRAINAGE SYSTEMS, IN
ACCORDANCE WITH CITY STANDARDS AND SPECIFICATIONS, BEHIND THE RIGHT-OF-WAY, OR AS POLICY
MAY DICTATE AT THE REAR PROPERTY LINE.
- THE DEVELOPER'S ENGINEER SHALL BE REQUIRED TO ASSURE IN AREAS BEING DEVELOPED, THAT
ADEQUATE DRAINAGE FACILITIES WILL BE INSTALLED, AS PER CITY STANDARDS AND SPECIFICATIONS, AT
ALL STREET INTERSECTIONS SO AS TO PREVENT PONDING OF WATER IN THE STREET INTERSECTION
CURBS.
- CONSTRUCTION SHALL NOT BEGIN PRIOR TO A PRELIMINARY CONSTRUCTION INSPECTION OF THE SITE.
CONTACT THE CONSTRUCTION ENGINEER / RIGHT-OF-WAY ADMINISTRATOR AT (704) 866-6015 AT LEAST
ONE (1) WORKING DAY PRIOR TO BEGINNING CONSTRUCTION.
NOTE:
CONTRACTOR SHALL REVIEW THESE PLANS IN CONJUNCTION WITH WITH THE
CURRENT SPECIFICATIONS AND STANDARD DETAILS FOR THE CITY OF
GASTONIA, NCDEQ, NCDOT AND OTHER JURISDICTIONS HAVING AUTHORITY
OVER THE PROJECT PRIOR TO 1) BIDDING THE PROJECT, 2) COMMENCING
CONSTRUCTION OF THE PROJECT. THE CONTRACTOR SHALL NOTIFY THE
ENGINEER IMMEDIATELY IF ANY DISCREPANCIES EXIST THAT WILL RESULT IN
THE CONSTRUCTION NOT BEING IN COMPLIANCE WITH AFOREMENTIONED
SPECIFICATIONS AND DETAILS.
REVISION #
SUMMARY OF REVISION
A
ADDRESSED CITY OF GASTONIA COMMENTS
A
ADDRESSED CITY OF GASTONIA COMMENTS
2A
AD
FOR CONSTRUCTION
PLAN REVIEW
04/19/2022
C ADDRESSED CITY OF GASTONIA COMMENTS 0411912022
B ADDRESSED CITY OF GASTONIA COMMENTS 0312312022
A ADDRESSED CITY OF GASTONIA COMMENTS 0210212022
REV.NO. DESCRIPTIONS DATE
CAR0
o�oFe$s,o.�,Z
050 77
C! �yGNIE
Q G
I� NBL.
IP \\�
CIVIL ENGINEER
�1VFIQM&CREED
8020 Tower Point Drive
Charlotte, North Carolina 28227
Phone: (704) 841-2588, Fax: (704) 841-2567
NC License# F-1222
www.mckimcreed.com
J_
U
ILL.
LU
(n
V
LL
O
U)
ILLL.
I
J
''L^U
VJ
LU
I..1_
J
LU
0
U
Z
Z
Z)
O
U
Z
O
U)
Q
Q
Z
O
Q
CD
0
U