Loading...
HomeMy WebLinkAboutWI0400345_Staff Report for Permit Modification_20220622Permit No. WI0400345 Date: June 22, 2022 County: Randolph To: Michael Rogers Permittee/Applicant: ERM, Inc Central Office Reviewer: Michael Rogers Facility Name: Energizer Manufacturing I, GENERAL INFORMATION 1. This application is (check all that apply): ❑ New ❑ Renewal ❑ Minor Modification ® Major Modification a. Date of Inspection: June 14, 2022 b. Person contacted and contact information: Alan Martin, PG; Phone: 704-409-3444 alan.martin@erm.com c. Site visit conducted by: Jim Gonsiewski. d. Inspection Report Printed from BIMS attached: ® Yes ❑ No. e. Physical Address of Site including zip code: 419 Art Bryan Drive Asheboro NC 27203 f. Driving Directions if rural site and/or no physical address: g. Latitude: 35°46'8.25"N Longitude:79°49'4.04"W Source of Lat/Long & accuracy (i.e., Google Earth, GPS, etc.): Google Earth II. DESCRIPTION OF INJECTION WELL(S) AND FACILITY 1. Type of injection system: ❑ Geothermal Heating/Cooling Water Return ® In situ Groundwater Remediation ❑ Non -Discharge Groundwater Remediation ❑ Other (Specify: ) 2. For Geothermal Water Return Well(s) only a. For existing geothermal system only: Were samples collected from Influent/Effluent sampling ports? ❑ Yes ❑ No. Provide well construction information from well tag: b. Does existing or proposed system use same well for water source and injection? ❑ Yes ❑ No If No, please provide source/supply well construction info (i.e., depth, date drilled, well contractor, etc.) and attached map and sketch location of supply well in relation to injection well and any other features in Section IV of this Staff Report. 3. Are there any potential pollution sources that may affect injection? ® Yes ❑ No What is/are the pollution source(s)? On -Site operations/previously identified groundwater contamination What is the distance of the injection well(s) from the pollution source(s) 50 feet 4. What is the minitnum distance of proposed injection wells from the property boundary? 30 ft 5. Quality of drainage at site: ❑ Good ® Adequate ❑ Poor 6. Flooding potential of site: 0 Low ® Moderate ❑ High 7. For Groundwater Injection Remediation Systems only, is the proposed and/or existing groundwater monitoring program (number of wells, frequency of monitoring, monitoring parameters, etc.) adequate? ® Yes ❑ No. If No, attach map of existing monitoring well network if applicable and recommend any changes to the groundwater -monitoring program. 8. Does the map included in the Application reasonably represent the actual site (property lines, wells, surface drainage)? ® Yes ❑ No. If No, or no map, please attach a sketch of the site. Show property boundaries, buildings, wells, potential pollution sources, roads, approximate scale, and north arrow. 9. For Non -Discharge Groundwater Remediation systems only (i.e., permits with WQ prefix): a. Are the treatment facilities adequate for the type of waste and disposal system? n Yes ❑ No ❑ N/A. If No, please explain: b. Are the site conditions (soils, topography, depth to water table, etc.) consistent with what was reported by the soil scientist and/or Professional Engineer? ❑ Yes ❑ No ❑ N/A. If no, please explain: HI. EVALUATION AND RECOMMENDATIONS 1. Do you foresee any problems with issuance/renewal of this permit? ❑ Yes ® No. If Yes, explain. 2. List any items that you would like WQROS Central Office to obtain through an additional information request. Make sure that you provide a reason for each item: Item Reason 3. List specific special conditions or compliance schedules that you recommend to be included in the permit when issued. Make sure that you provide a reason for each special condition: Condition Reason 4. Recommendation ❑ Deny. If Deny, please state reasons: ❑ Hold pending receipt and review of additional information by Regional Office ❑ Issue upon receipt of needed additional information ® Issue 5. Signature of Report Preparer(s): Signature of WQROS Regional Supervisor: Date: 6/22/2022 FP DocuSlgned by: 619711beFiII bRIeeueloned by: 1. JMJU' `-145849E225C94EA... IV. ADDITIONAL REGIONAL STAFF REVIEW COMMENTS/ATTACHMENTS (Optional/If Needed) View looking north of the waste storage area. ��a •t View looking east of the tank farm enclosure. Note the air sparging and soil vapor extraction wells between the berm and the wall of the enclosure. View looking south along the west side of the facility. The tank farm is to the immediate left. View looking south along the east side of the tank farm. Note the air sparging well near the bottom center of the photograph. View of an observation well at the southeast corner of the tank farm. The ISCO injection pilot test was conducted in this area. View of the soil vapor extraction system in the interior of the facility. This system is currently not operating. Permit: WI0400345 SOC: County: Randolph Region: Winston-Salem Compliance Inspection Report Effective: 09/27/19 Effective: Contact Person: Scott Boyle Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Expiration: 08/30/24 Expiration: Title: Inspection Date: 06/14/2022 Entry Time 08:35AM Primary Inspector: Jim J Gonsiewski Secondary Inspector(s): Reason for Inspection: Other Certification: Owner : Energizer Manufacturing Inc Facility: Energizer Manufacturing Inc. 419 Art Bryan Dr Asheboro NC 272033089 Exit Time: 09:50AM Phone: 336-672-4546 Phone: Phone: 336-776-9704 Inspection Type: Reconnaissance Permit Inspection Type: Injection In situ Groundwater Remediation Well Facility Status: Compliant ❑ Not Compliant Question Areas: IIII Wells System Operations (See attachment summary) Page 1 of 3 Permit: WI0400345 Owner - Facility: Energizer Manufacturing Inc Inspection Date: 06/14/2022 Inspection Type : Reconnaissance Reason for Visit: Other Inspection Summary: On June 14, 2022, staff of the North Carolina Division of Water Resources Winston-Salem Regional Office (DWR) performed a reconaissance inspection of the subject facility in conjunction with a UIC permit modification application review. This inspection was conducted by DWR staff person Jim Gonsiewski. The inspection concentrated in the areas that will be part of the planned expansion of the injection system. The facility is very well maintained. No problems with the proposed modification were noted. Page 2 of 3 Permit: WI0400345 Owner - Facility: Energizer Manufacturing Inc Inspection Qate: 06/14/2022 Inspection Type : Reconnaissance Reason for Visit: Other System Operation Is same well used as source well and injection well? Is injection well capable of assimilating injected fluid? Injection flow rate at time of inspection (gpm) Has system owner/operator noticed any abnormalities (turbidity, air in system, poor heating/cooling, etc) in system operation? Comment on system operation Is system operation and construction consistent with that described in application? Describe inconsistencies between application and observed operation/construction The system was not in operation. The areas were well maintained. Do not anticipate any problems with the modifications to the system Comment: Yes No NA NE ❑ • ❑ ❑ ■ ❑❑❑ 0 ❑•❑ ❑ ■ ❑❑❑ ■ ❑❑❑ Page 3 of 3