Loading...
HomeMy WebLinkAboutNC0086169_Permit (Modification)_20011031 (2)NPDES DOCUHENT SCANNIN` COVER SHEET NC0086169 Corning / Midland facility NPDES Permit: Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Correspondence Speculative Limits Instream Assessment (67b) Environmental Assessment (EA) Permit History Document Date: October 31, 2001 This document is printed on reuse paper - ignore any content on the reYerse side Scate of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Gregory J. Thorpe, Ph.D., Acting Director Ms. Christy L. Hannan Corning Incorporated P.O. Box 1700 Concord, North Carolina Dear Ms. Hannon: 28026-1700 A7A NCDENR October 31, 2001 Subject: Modification of NPDES Permit NC0086169 Midland Plant Cabarrus County Division personnel have reviewed and approved your request for modification of the subject permit. Accordingly, we are forwarding this revised NPDES permit. This permit modification is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated May 9,1994 (or as subsequently amended). Changes to the permit include: ➢ As stated in your previous correspondence, a priority pollutant analysis is required once per permit cycle. The current permit cycle began on May 1, 2000 and ends on October 31, 2003. Any pollutant analysis conducted within this time frame is considered within the permit cycle. > The flow limit for flush water in Special Condition A. (9.) has been increased to 250,000 gallons per day. Corning's Annual Shutdown Procedures should include the provision that both cooling towers should not be flushed at the same time. > Special condition A. (7.) has been modified. Biological monitoring may be conducted after completion of the expansion but must be completed prior to submitting the application for renewal of the NPDES permit in 2003. If any parts, measurement frequencies or sampling requirements contained in this permit modification are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final.and binding. Please note that this permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does -not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, the Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Michael Myers at telephone number (919) 733-5083, extension 508. Sincerely Original Signed By David A. Goodrich Gregory J. Thorpe, Ph.D. Acting Director cc: Mooresville Regional Office/Water Quality Section Point Source Compliance Enforcement Unit Technical Assistance & Certification Unit Aquatic Toxicology Unit Central Files NPDES Files f 1617 MAIL SERVICE CENTER, RALEIGH, NORTH CAROLINA 27699-1617 - TELEPHONE 919-733-5083/FAX 919-733-0719 AN EQUAL OPPORTUNITY AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/ 1 0% POST -CONSUMER PAPER VISIT US ON THE INTERNET @ http://h2o.enr.state.nc.us/NPDES Permit NC0086169 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Corning Incorporated is hereby authorized to discharge wastewater from a facility located at the Midland Plant U.S. Highway 601 near Midland Cabarrus County to receiving waters designated as an unnamed tributary of Muddy Creek (outfall 001), an unnamed tributary of Clear Creek (outfall 002) and the Rocky River (outfall 003) in the Yadkin -Pee Dee River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective December 1, 2001. This permit and authorization to discharge shall expire at midnight on October 31, 2003. Signed this day October 31, 2001. Original Signed By David A. Goodrich Gregory J. Thorpe, Ph.D., Acting Director Division of Water Quality By Authority of the Environmental Management Commission Permit NC00861t9 • SUPPLEMENT TO PERMIT COVER SHEET Corning Incorporated is hereby authorized to: 1. Continue operation of a 0.107 MGD wastewater treatment facility (outfall 003) located at the Corning Incorporated Midland Plant off U.S. Highway 601 near Midland in Cabarrus County. The wastewater treatment facility consists of the following treatment units: • Equalization tank • Off -spec tank • Two Lamella clarifier • Two neutralization tanks • Neutralization transfer tank • Chloride stabilization tank • Surge blend tank 2. After receiving Authorization to Construct from the Division of Water Quality, construct and operate facilities for the discharge of up to 0.142 MGD through outfall 003; and 3. Discharge stormwater and boiler blowdown from a wet detention pond into an unnamed tributary of Clear Creek (outfall 002); discharge stormwater from a wet retention pond into an unnamed tributary of Muddy Creek (Outfall 001— See A. (8.) Stormwater Monitoring, Controls and Limitations for Permitted Discharges, for monitoring requirements); and discharge process wastewater, cooling tower blowdown, and carbon filter backwash from the above referenced treatment works at the location specified on the attached map into the Rocky River (Outfall 003). All receiving streams are classified C waters in the Yadkin -Pee Dee River basin. —I County Boundary • NPDES discharger Hydrography Highway • Coalition Monitoring Site * Benthic Site Municipal boundary ( J N • Corning Incorporated NC0086169 Cabarrus County 2 0 2 Miles Facility Information State Grid: G 16 NE and G 17 NW USGS Quad: Midland and Stanfield Subbasin: 03-07-12 • r '--(`c`, �)�' Coming Incorporated A Permit NC0086169 A. (1.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS (002) During the period beginning on the effective date of this permit and lasting until permit expiration, the Permittee is authorized to discharge from outfall serial number 002 — Stormwater and Humidification Boiler Blowdown. Such discharges shall be limited and monitored by the Permittee as specified below: M ►th�lY Average Daily Average Monitoring _Reauiremients easuxe�aaent Ere uency Flow Semi-annually Estimate Effluent Temperaturee Semi-annually Grab Effluent Total residual chlorine Semi-annually Grab Effluent Footnotes: 1. The effluent for this outfall shall mean a point upstream of the mixing point with stormwater. 2. The temperature of the effluent will be regulated so that the temperature of the receiving stream does not increase more than 2.8°C above the natural water temperature. Receiving water temperature will not exceed a maximum of 32°C. There shall be no chromium, zinc or copper added to the treatment system except as pre -approved additives to biocidal compounds. See Special Condition A. (9.) Annual Shutdown Procedures Condition. The permittee shall obtain authorization from the Division prior to the use of biocide in the cooling water. The permittee shall notify the Director in writing at least ninety (90) days prior to instituting use of any additional biocide in the treatment system which may be toxic to aquatic life (other than biocides previously reported to the Division). Such notification shall include completion of Biocide Worksheet 101 and a map indicating the discharge point and receiving stream. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. There shall be no discharge of floating solids or visible foam in other than trace amounts. Conditions related to the stormwater portion of this outfall can be found in A. (8.) Stormwater Monitoring, Controls and Limitations for Permitted Discharges. Permit NC0086169 A. (2.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS (003 at 0.107) During the period beginning on the effective date of the permit and lasting until expansion beyond 0.107 MGD, the Permittee is authorized to discharge from outfall serial number 003 — Industrial Process Wastewater, Non -contact Cooling Water, and Carbon Filter Backwash. Such discharges shall be limited and monitored by the Permittee as specified below: Effluent. Characteristics Limits Monitorin�r:Requirements: Mo ithly Avera e g Daily Average , - Measurement j , Frequency ' Sam: le _e ' ::_: ; Sant le Location`, Flow 0.107 MGD Continuous Estimate Effluent' Total Residual Chlorine 28 µg/L 2/Week Grab Effluent Chloride 2/Week Composite Effluent Total Suspended Solids 30.0 mg/L 45.0 mg/L Weekly Composite Effluent Temperature2 Weekly Grab Effluent pH3 Weekly Grab Effluent Cadmium4 Monthly Grab Effluent Copper4 Monthly Grab Effluent Zinc' Monthly Grab Effluent Total Phosphorus Quarterly Composite Effluent Chronic Toxicity5 Quarterly Composite Effluent Pollutant Analysis6 6 Effluent Footnotes: 1. The compliance point for flow shall be upstream of the non -contact cooling water and boiler blowdown internal outfall. The compliance point for all other parameters shall be at the Rocky River discharge location. 2. The temperature of the effluent will be regulated so that the temperature of the receiving stream does not increase more than 2.8°C above the natural water temperature. Receiving water temperature will not exceed a maximum of 32°C. 3. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. 4. After seven sampling events the permittee, may request (in writing) that the Division evaluate this parameter and modify the permit accordingly. 5. Chronic Toxicity (Ceriodaphnia) at 1.0%; January, April, July and October (see A. (4.)). 6. See A. (6.) Pollutant Analysis Condition. See Special Condition A. (9.) Annual Shutdown Procedures Condition There shall be no discharge of floating solids or visible foam in other than trace amounts. Defintions: MGD — Million gallons per day µg/L — Micrograms per liter mg/L — Milligram per liter Permit NC0086169 A. (3.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS (003 at 0.142) During the period beginning upon expansion beyond 0.107 MGD and lasting until expiration, the Permittee is authorized to discharge from outfall serial number 003 — Industrial Process Wastewater, Non -contact Cooling Water, and Carbon Filter Backwash. Such discharges shall be limited and monitored by the Permittee as specified below: Flow Monthly Average 0.142 MGD e- :Monitoring, Requirements Continuous Estimate Effluent' Total Residual Chlorine Chloride 28 µg/L 2/Week 2/Week Grab Composite Effluent Effluent Total Suspended Solids Temperature2 pH3 Cadmium4 Copper4 Zinc 30.0 mg/L 45.0 mg/L Weekly Composite Effluent Weekly Weekly Monthly Grab Grab Grab Effluent Effluent Effluent Monthly Monthly Grab Grab Effluent Effluent Total Phosphorus Chronic Toxicity5 Pollutant Analysis6 Quarterly Quarterly 6 Composite Composite Effluent Effluent Effluent Footnotes: 1 • The compliance point for flow shall be upstream of the non -contact cooling water and boiler blowdown internal outfall. The compliance point for all other parameters shall be at the Rocky River discharge location. 2. The temperature of the effluent will be regulated so that the temperature of the receiving stream does not increase more than 2.8°C above the natural water temperature. Receiving water temperature will not exceed a maximum. of 32°C. 3. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. 4. After seven sampling events the permittee, may request (in writing) that the Division evaluate this parameter and modify the permit accordingly. 5. Chronic Toxicity (Ceriodaphnia) at 1.7%; January, April, July and October (see A. (5.)). 6. See A. (6.) Pollutant Analysis Condition. See Special Condition A. (9.) Annual Shutdown Procedures Condition There shall be no discharge of floating solids or visible foam in other than trace amounts. Definitions: MGD — Million gallons per day µg/L — Micrograms per liter mg/L - Milligram per liter Permit NC0086169 A. (4.) CHRONIC TOXICITY PERMIT LIMIT (Quarterly test at 0.107 MGD) The effluent discharge shall at no time exhibit observable inhibition of reproduction or significant mortality to Ceriodaphnia dubia at an effluent concentration of 1.0%. The permit holder shall perform at a minimum, quarterly monitoring using test procedures outlined in the "North Carolina Ceriodaphnia Chronic Effluent Bioassay Procedure," Revised February 1998, or subsequent versions or "North Carolina Phase II Chronic Whole Effluent Toxicity Test Procedure" (Revised -February 1998) or subsequent versions. The tests will be performed during the months of January, April, July, October. Effluent sampling for this testing shall be performed at the NPDES permitted final effluent discharge below all treatment processes. If the test procedure performed as the first test of any single quarter results in a failure or ChV below the permit limit, then multiple -concentration testing shall be performed at a minimum, in each of the two following months as described in "North Carolina Phase II Chronic Whole Effluent Toxicity Test Procedure" (Revised -February 1998) or subsequent versions. The chronic value for multiple concentration tests will be determined using the geometric mean of the highest concentration having no detectable impairment of reproduction or survival and the lowest concentration that does have a detectable impairment of reproduction or survival. The definition of "detectable impairment," collection methods, exposure regimes, and further statistical methods are specified in the "North Carolina Phase II Chronic Whole Effluent Toxicity Test Procedure" (Revised - February 1998) or subsequent versions. All toxicity testing results required as part.of this permit condition will be entered on the Effluent Discharge Monitoring Form (MR-1) for the months in which tests were performed, using the parameter code TGP3B for the pass/fail results and THP3B for the Chronic Value. Additionally, DWQ Form AT-3 (original) is to be sent to the following address: Attention: NC DENR / DWQ / Environmental Sciences Branch 1621 Mail Service Center Raleigh, North Carolina 27699-1621 Completed Aquatic Toxicity Test Forms shall be filed with the Environmental Sciences Branch no later than 30 days after the end of the reporting period for which the report is made. Test data shall be complete, accurate, include all supporting chemical/physical measurements and all concentration/response data, and be certified by laboratory supervisor and ORC or approved designate signature. Total residual chlorine of the effluent toxicity sample must be measured and reported if chlorine is employed for disinfection of the waste stream. Should there be no discharge of flow from the facility during a month in which toxicity monitoring is required, the permittee will complete the information located at the top of the aquatic toxicity (AT) test form indicating the facility name, permit number, pipe number, county, and the month/year of the report with the notation of "No Flow" in the comment area of the form. The report shall be submitted to the Environmental Sciences Branch at the address cited above. Should the permittee fail to monitor during a month in which toxicity monitoring is required, monitoring will be required during the following month. Should any test data from this monitoring requirement or tests performed by the North Carolina Division of Water Quality indicate potential impacts to the receiving stream, this permit may be re -opened and modified to include alternate monitoring requirements or limits. NOTE: Failure to achieve test conditions as specified in the cited document, such as minimum control organism survival, minimum control organism reproduction, and appropriate environmental controls, shall constitute an invalid test and will require immediate follow-up testing to be completed no later than the last day of the month following the month of the initial monitoring. Permit NC0086169 A. (5.) CHRONIC TOXICITY PERMIT LIMIT (Quarterly test at 0.142 MGD) The effluent discharge shall at no time exhibit observable inhibition of reproduction or significant mortality to Ceriodapbnia dubia at an effluent concentration of 1.7%. The permit holder shall perform at a minimum, quarterly monitoring using test procedures outlined in the "North Carolina Ceriodapbnia Chronic Effluent Bioassay Procedure," Revised February 1998, or subsequent versions or "North Carolina Phase II Chronic Whole Effluent Toxicity Test Procedure" (Revised -February 1998) or subsequent versions. The tests will be performed during the months of January, April, July, October. Effluent sampling for this testing shall be performed at the NPDES permitted final effluent discharge below all treatment processes. If the test procedure performed as the first test of any single quarter results in a failure or ChV below the permit limit, then multiple -concentration testing shall be performed at a minimum, in each of the two following months as described in "North Carolina Phase II Chronic Whole Effluent Toxicity Test Procedure" (Revised -February 1998) or subsequent versions. The chronic value for multiple concentration tests will be determined using the geometric mean of the highest concentration having no detectable impairment of reproduction or survival and the lowest concentration that does have a detectable impairment of reproduction or survival. The definition of "detectable impairment," collection methods, exposure regimes, and further statistical methods are specified in the "North Carolina Phase II Chronic Whole Effluent Toxicity Test Procedure" (Revised - February 1998) or subsequent versions. All toxicity testing results required as part of this permit condition will be entered on the Effluent Discharge Monitoring Form (MR-1) for the months in which tests were performed, using the parameter code TGP3B for the pass/fail results and THP3B for the Chronic Value. Additionally, DWQ Form AT-3 (original) is to be sent to the following address: Attention: NC DENR / DWQ / Environmental Sciences Branch 1621 Mail Service Center Raleigh, North Carolina 27699-1621 Completed Aquatic Toxicity Test Forms shall be filed with the Environmental Sciences Branch no later than 30 days after the end of the reporting period for which the report is made. Test data shall be complete, accurate, include all supporting chemical/physical measurements and all concentration/response data, and be certified by laboratory supervisor and ORC or approved designate signature. Total residual chlorine of the effluent toxicity sample must be measured and reported if chlorine is employed for disinfection of the waste stream. Should there be no discharge of flow from the facility during a month in which toxicity monitoring is required, the permittee will complete the information located at the top of the aquatic toxicity (AT) test form indicating the facility name, permit number, pipe number, county, and the month/year of the report with the notation of "No Flow" in the comment area of the form. The report shall be submitted to the Environmental Sciences Branch at the address cited above. Should the permittee fail to monitor during a month in which toxicity monitoring is required, monitoring will be required during the following month. Should any test data from this monitoring requirement or tests performed by the North Carolina Division of Water Quality indicate potential impacts to the receiving stream, this permit may be re -opened and modified to include alternate monitoring requirements or limits. NOTE: Failure to achieve test conditions as specified in the cited document, such as minimum control organism survival, minimum control organism reproduction, and appropriate environmental controls, shall constitute an invalid test and will require immediate follow-up testing to be completed no later than the last day of the month following the month of the initial monitoring. Permit NC0086169 i A. (6.) POLLUTANT ANALYSIS CONDITION The Permittee shall conduct a test for pollutants once per permit cycle at the effluent from the treatment plant. The discharge shall be evaluated as follows: 1) A pollutant analysis of the effluent must be completed using EPA approved methods for the following analytic fractions: (a) purgeables (i.e., volatile organic compounds); (b) acid extractables; (c) base/neutral extractables; (d) organochlorine pesticides and PCBs; (e) herbicides; and (f) metals and other inorganics. The Annual Pollutant Analysis Monitoring (APAM) Requirement Reporting Form A and accompanying memo describes the sampling and analysis requirements and lists chemicals to be included in the pollutant analysis. This monitoring requirement is to be referred to as the "Pollutant Analysis Monitoring Requirement" (PAM). 2) Other significant levels of organic chemicals must be identified and approximately quantified. For the purpose of implementing this requirement, the largest 10 GC/MS peaks in the purgeable, base/neutral extractable, and acid exractable fractions (or fewer than 10 if less than 10 unidentified peaks occur) for chemicals other than those specified on the APA Requirement Reporting Form A should be identified and approximately quantified as stated in the APAM Reporting Form A instructions. This part (item 2) of the APAM requirement is to be referred to as the "10 significant peaks rule"). A. (7.) Biological Monitoring Condition After completion of the expansion to 0.142 MGD, the Permittee shall conduct an upstream and downstream benthic macroinvertebrate survey. This survey should be conducted between the months of June and September. A report of the findings of this survey shall be completed and included with the permit application package at the time of permit renewal. For technical assistance regarding this permit requirement, please contact the Division's Biological Assessment Unit at (919) 733-6946. A. (8.) STORMWATER MONITORING, CONTROLS AND LIMITATIONS FOR PERMITTED DISCHARGES FINAL LIMITATIONS AND CONTROLS FOR STORMWATER DISCHARGES During the period beginning on the effective date of the permit and lasting until expiration, the permittee is authorized to discharge stormwater associated with industrial activity from outfalls 001 and 002. Such discharges shall be controlled, limited and monitored as specified below. 1. Stormwater Pollution Prevention Plans The permittee shall develop and continue to update a Stormwater Pollution Prevention Plan, herein after referred to as the Plan. The Plan shall be considered public information in accordance with Part III, Standard Conditions, Section E.10. of this permit. The Plan shall include, at a minimum, the following items: a. Site Plan: The site plan shall provide a description of the physical facility and the potential pollutant sources which may be expected to contribute to contamination of regulated stormwater discharges. The site plan shall contain the following: Permit NC0086169 (1) A general location map (USGS quadrangle map, or appropriately drafted equivalent map), showing the facility's location in relation to transportation routes and surface waters, and the name of the receiving water(s) to which the stormwater outfall(s) discharges. If the discharge is to a municipal separate storm sewer system, the name of the municipality and the ultimate receiving waters, and accurate latitude and longitude of the point(s) of discharge must be shown. (2) A narrative description of storage practices, loading and unloading activities, outdoor process areas, dust or particulate generating or control processes, and waste disposal practices. (3) A site map (or series of maps) drawn to scale with the distance legend indicating location of industrial activities (including storage of materials, disposal areas, process areas, and loading and unloading areas), drainage structures, drainage areas for each outfall and activities occurring in the drainage area, building locations and impervious surfaces, the percentage of each drainage area that is impervious. For each outfall, a narrative description of the potential pollutants which could be expected to be present in the regulated stormwater discharge. (4) A list of significant spills or leaks of pollutants that have occurred at the facility during the 3 previous years and any corrective actions taken to mitigate spill impacts. (5) Certification that the stormwater outfalls have been evaluated for the presence of non-stormwater discharges. The certification statement will be signed in accordance with the requirements found in Part III, Standard Conditions, Section B.11. b. Stormwater Management Plan: The stormwater management plan shall contain a narrative description of the materials management practices employed which control or minimize the exposure of significant materials to stormwater, including structural and non-structural measures. The stormwater management plan, at a minimum, shall incorporate the following: (1) A study addressing the technical and economic feasibility of changing the methods of operations and/or storage practices to eliminate or reduce exposure of materials and processes to stormwater. Wherever practicable the permittee should consider covering storage areas, material handling operations, manufacturing or fueling operations to prevent materials exposure to stormwater. In areas where elimination of exposure is not practicable, the stormwater management plan shall document the feasibility of diverting the stormwater runoff away from areas of potential contamination. (2) A schedule to provide secondary containment for bulk storage of liquid materials, storage of Section 313 of Title III of the Superfund Amendments and Reauthorization Act (SARA) water priority chemicals, or storage of hazardous materials to prevent leaks and spills from contaminating stormwater runoff. If the secondary containment devices are connected directly to stormwater conveyance systems, the connection shall be controlled by manually activated valves or other similar devices [which shall be secured with a locking mechanism] and any stormwater that accumulates in the containment area shall be at a minimum visually observed prior to release of the accumulated stormwater. Accumulated stormwater shall be released if found to be uncontaminated. Records documenting the individual making the observation, the description of the accumulated stormwater and the date and time of the release shall be kept for a period of five years. (3) A narrative description of Best Management Practices (BMPs) to be considered such as, but not limited to, oil and grease separation, debris control, vegetative filter strips, infiltration and stormwater detention or retention, where necessary. The need for structural BMPs shall be based on the assessment of potential of sources contributing significant quantities of pollutants to stormwater discharges and data collected through monitoring of stormwater discharges. (4) Inspection schedules of stormwater conveyances and controls and measures to be taken to limit or prevent erosion associated with the stormwater systems. Permit NC0086169 c. Spill Prevention and Response Plan: The Spill Prevention and Response Plan shall incorporate a risk assessment of potential pollutant sources based on a materials inventory of the facility. Facility personnel (or team) responsible for implementing the plan shall be identified in the plan. A responsible person shall be on -site at all times during facility operations that have the potential to contaminate stormwater runoff through spills or exposure of materials associated with the facility operations. d. Preventative Maintenance and Good Housekeeping Program: A preventative maintenance program shall be developed. The program shall document schedules of inspections and maintenance activities of stormwater control systems, plant equipment and systems. Inspection of material handling areas and regular cleaning schedules of these areas shall be incorporated into the program. e. Training schedules shall be developed and training provided at a minimum on an annual basis on proper spill response and cleanup procedures and preventative maintenance activities for all personnel involved in any of the facility's operations that have the potential to contaminate stormwater runoff. Facility personnel (or team) responsible for implementing the training shall be identified in the plan. f. The Stormwater Pollution Prevention Plan shall identify a specific position(s) responsible for the overall coordination, development, implementation, and revision to the Plan. Responsibilities for all components of the Plan shall be documented and position(s) assignments provided. g• Plan Amendment: The permittee shall amend the Plan whenever there is a change in design, construction, operation, or maintenance which has a significant effect on the potential for the discharge of pollutants via a point source to surface waters. The Stormwater Pollution Prevention Plan shall be reviewed and updated on an annual basis. The Director may notify the permittee when the Plan does not meet one or more of the minimum requirements of the permit. Within 30 days of such notice, the permittee shall submit a time schedule to the Director for modifying the Plan to meet minimum requirements. The permittee shall provide certification in writing (in accordance with Part III, Standard Conditions, Section B.11.) to the Director that the changes have been made. h. Facility Inspections: Inspections of the facility and all stormwater systems shall occur at a minimum on a semiannual schedule, once in the fall (September - November) and once during the spring (April - June). The inspection and any subsequent maintenance activities performed shall be documented, recording date and time of inspection, individual(s) making the inspection and a narrative description of the facility's stormwater control systems, plant equipment and systems. Records of these inspections shall be incorporated into the Stormwater Pollution Prevention Plan. Visual monitoring as required in Part II, Section A.2. shall be performed in addition to facility inspections. Implementation: Implementation of the Plan shall include documentation of all monitoring, measurements, inspections, maintenance activities and training provided to employees, including the log of the sampling data. Activities taken to implement BMPs associated with the industrial activities, including vehicle maintenance activities, must also be recorded. All required documentation shall be kept on -site for a period of five years and made available to the Director or his authorized representative immediately upon request. 2. Visual Monitoring Visual monitoring requires a qualitative visual inspection of each stormwater outfall, regardless of representative outfall status, for the purpose of evaluating the effectiveness of the Stormwater Pollution Prevention Plan and assessing new sources of stormwater pollution. No analytical tests are required. Visual monitoring of stormwater outfalls does not need to be performed during a representative storm event. Permit NC0086169 Stormwater Discharge Characteristics Frequency ; Monitoring 'Ty_pe2 Monitbring Location3 Color Semi-annual Visual SDO Odor Semi-annual Observation SDO Clarity Semi-annual Visual SDO Floating Solids Semi-annual Visual SDO Suspended Solids Semi-annual Visual SDO Foam Semi-annual Visual SDO Oil Sheen Semi-annual Visual SDO Other obvious indicators of stormwater pollution Semi-annual Visual SDO 1 Frequency: The first visual monitoring event during the term of the permit must be performed during the initial analytical monitoring event. All subsequent visual monitoring will be performed twice per year, once in the spring and once in the fall. 2 Monitoring Type: Monitoring requires a qualitative observation of each stormwater outfall. No analytical testing or sampling is required. 3 Sample Location: Stormwater Discharge Outfall (SDO — effluent at outfalls 001 and 002). STORMWATER DEFINITIONS 1. Best Management Practices (BMPs) Schedules of activities, prohibitions of practices, maintenance procedures, and other management practices to prevent or reduce the pollution of waters of the United States. BMPs also include treatment requirements, operation procedures, and practices to control plant site runoff, spillage or leaks, sludge or waste disposal, or drainage from raw material storage. 2. Bulk Storage of Liquid Products Liquid raw materials, manufactured products, waste materials or by-products with a single above ground storage container having a capacity of greater than 660 gallons or with multiple above ground storage containers having a total storage capacity of greater than 1,320 gallons. 3. Point Source Discharge Any discernible, confined and discrete conveyance, including but specifically not limited to, any pipe, ditch, channel, tunnel, conduit, well, discrete fissure, container, rolling stock, or concentrated animal feeding operation from which pollutants are or may be discharged to waters of the state. 4. Runoff Coefficient The fraction of total rainfall that is not infiltrated into or otherwise retained by the soil, concrete, asphalt or other surface upon which it falls that will appear at the conveyance as runoff. 5. Secondary Containment Spill containment for the contents of the single largest tank within the containment structure plus sufficient freeboard to allow for the 25-year, 24-hour storm event. Permit NC0086169 6. Section 313 Water Priority Chemical A chemical or chemical category which: a. Is listed in 40 CFR 372.65 pursuant to Section 313 of Title III of the Superfund Amendments and Reauthorization Act (SARA) of 1986, also titled the Emergency Planning and Community Right -to -Know Act of 1986; b. Is present at or above threshold levels at a facility subject to SARA title III, Section 313 reporting requirements; and c. That meet at least one of the following criteria: (1) Is listed in appendix D of 40 CFR part 122 on either Table II (organic priority pollutants), Table III (certain metals, cyanides, and phenols) or Table IV (certain toxic pollutants and hazardous substances); (2) Is listed as a hazardous substance pursuant to section 311(b)(2)(A) of the CWA at 40 CFR 116.4; or (3) Is a pollutant for which EPA has published acute or chronic water quality criteria. 7. Significant Materials Includes, but is not limited to: raw materials; fuels; materials such as solvents, detergents, and plastic pellets; finished materials such as metallic products; raw materials used in food processing or production; hazardous substances designated under section 101(14) of CERCLA; any chemical the facility is required to report pursuant to section 313 of Title III of SARA; fertilizers; pesticides; and waste products such as ashes, slag and sludge that have the potential to be released with stormwater discharges. 8. Significant Spills Includes, but is not limited to: releases of oil or hazardous substances in excess of reportable quantities under section 311 of the Clean Water Act (Ref: 40 CFR 110.10 and CFR 117.21) or section 102 of CERCLA (Ref: 40 CFR 302.4). 9. Stormwater Runoff The flow of water which results from precipitation and which occurs immediately following rainfall or as a result of snowmelt. 10. Total Flow The flow corresponding to the time period over which the sample collection occurs. The total flow calculated based on the size of the area draining to the outfall, the amount of the built -upon (impervious) surfaces within the drainage area, and the total amount of rainfall occurring during the sampling period. 11. Visible Sedimentation Solid particulate matter, both mineral and organic; that has been or is being transported by water, air, gravity, or ice from its site of origin, which can be seen with the unaided eye. A. (9.) Annual Shutdown Procedures Condition On an annual basis, the permittee is permitted to discharge up to 250,000 gallons of non -contact cooling water and flush water, from the two cooling tower basins, through Outfall 002. The semi-annual monitoring associated with outfall 002 shall coincide with this event. Corning Incorporated shall develop a HVAC Cooling Tower Shutdown Procedure consistent with BetzDearborn recommendations. The HVAC Cooling Tower Shutdown Procedure should include the condition that both cooling towers will not be flushed at the same time. This procedure shall be kept on site and available for review by Division staff upon request. Additionally, the time and duration for the discharge of non -contact cooling water through outfall 002 shall be recorded in the operations log by the Operator in Responsible Charge and available for review by the Division upon request. Corning Incorporated PO Box 1700 Optical Fiber Concord, NC 28026-17oo September 14, 2001 CERTIFIED MAIL RETURN RECEIPT REQUESTED t 704 569 600o www.corning.com Mr. Dave Goodrich North Carolina Department of Environment and Natural Resources Division of Water Quality, NPDES Permit Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 LJ(- r- r•- I F— U c la;6 "L RE: Corning Incorporated, Concord Facility NPDES Permit No. NC0086169 Duly Authorized Representative Dear Mr. Goodrich: CORNING Discovering 8 nd Ima 'natfo Xttaclied, please find the written authorization provided by Joseph Monastra, Corning, Inc., Concord Plant Manager for me to sign the facility's DMRs. This authorization has been on file in the Environmental Control Library since it was signed in October 1999 for review by DWQ. I want to insure it is part of our DWQ file. Please feel free to contact me if you have any questions concerning the information contained in the document. I can be reached at (704) 569-6268. Sincerely, Christy Hannan Environmental Control Engineer Concord Plant Corning, Inc. Enclosures Cc: Mooresville Regional Office, NCDENR Corning Incorporated Telecommunications Products Division P.O. Box 1700 Concord, North Carolina 28026-1700 704-569-6000 CORNING October 20, 1999 FOR INTERNAL USE ONLY To Whom it May Concern: As of this date, I hereby designate Christy Hannan, Environmental Control Engineer, Corning, Inc., as my authorized agent to sign as System Owner/Admin. Officer for North Carolina Department of Environment and Natural Resources, Designation Form Operator in Responsible Charge of Water Pollution Control Systems. This will allow Ms. Hannan to sign Discharge Monthly Reports (DMR's) for the Corning, Inc., Concord Plant. Sincerely, Joseph Monastra Plant Manager Concord Plant Corning, Inc. Vv) The Independent Tribune NORTH CAROLINA CABARRUS COUNTY PUBLIC NOTICE STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION/ NPDES UNIT 1617 MAIL SERVICE CENTER RALEIGH. NC 27699-1617 NOTIFICATION OF INTENT TO ISSUE A NPDES WASTEWATER PERMIT On the basis of thorough staff review and application of NC General Statute 143.21, Public law 92-500 and other lawful standards and regulations, the North Carolina Environmental Management Commission proposes to issue a National Pollutant Discharge Elimination System (NPDES) wastewater discharge permit to the person(s) listed below effective 45 days from the publish date of this notice. Written comments regarding the proposed permit will be accepted until 30 days after the publish date of this notice. All comments received prior to that date are considered in the final determinations regarding the proposed permit. The Director of the NC Division of Water Quality may decide to hold a public meeting for the proposed permit should the Division receive a significant degree of public interest. Copies of the draft permit and other supporting information on file used to determine conditions present in the draft permit are available upon request and payment of the costs of reproduction. Mail comments and/or requests for information to the NC Division of Water Quality at the above address or call Ms. Christie Jackson at (919) 733.5083. extension 538. Please include the NPDES permit number (attached) in any communication. Interested persons may also visit the Division of Water Quality at 512 N. Salisbury Street, Raleigh, NC 27604.114B between the hours of 8:00 a.m. and 5:00 p.m. to review information on tile. NPDES Permit Number NC0086169, Corning, Inc. - Fiber Optic Plant, P.O. Box 1700, Concord, NC 28026 has applied for a modification for a facility located in Cabarrus County discharging treated wastewater into Rocky River in the Yadkin Pee Dee River Basin. Currently no parameters are water quality limited. This discharge may affect future allocations in this portion of the receiving stream. NO. 399. May 24, 2001 On this, the 5 day of Mc—. 20 C. I ""---011L\\\ sr�; �4 i of The INDEPENDENT TRIBUNE, certifies that the annexed advertisement was duly inserted in the paper on the following dates: m�� z�4, ��c 1 and was published therein for weeks. The total cost of this advertisement $ Signed lv � Jul pONR Itil SOURCE BRAN ViMER H Corning Incorporated PO Box 17oo Optical Fiber Concord, NC 28o26-17oo June 11, 2001 CERTIFIED MAIL RETURN RECEIPT REQUESTED t 704 569 6000 www.corning.com Mr. Mike Myers, EIT North Carolina Department of Environment and Natural Resources Division of Water Quality, NPDES Permit Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: Corning Incorporated, Concord Facility NPDES Permit No. NC0086169 Draft Permit Modification Comments Dear Mr. Myers: CORNur phone conversation, May 23, 2001, we have reviewed the subject draft permit °'u°"'""tri iafffi"'artion. The comments I provided over the phone are presented below. ijo ef 1) The permit expires October 31, 2003. Biological monitoring is required between June and September 2004. These results are to be included in the permit renewal package. Please revise these dates. (We completed a biological monitoring in 1999.) 2) A pollutant analysis is required once during the permit cycle. We have just completed this analysis this spring. We also completed one in 2000. With the permit cycle ending in 2003, can we be covered by the 2001 analysis until the next permit cycle (> 2003)? In addition, with the Concord II non -contact cooling water system coming on line, we need to increase the volume of non -contact cooling water we need to discharge to Outfall 002 during annual shutdown as described in Section A.(9) of the draft permit. Annual maintenance will require the flushing of two cooling tower basins instead of the original one. This will increase the volume of water to 250,000 gallons. The basins will not be flushed at the same time and the procedures described in Section A.(9) will be followed for both basins. — 5 . C , 4(.7) is d,,f.'.o1 ► — a.LiLj Please feel free to contact me if you have any questions concerning the information above. I can be reached at (704) 569-6268. Sincerely, Christy Hannan Environmental Control Engineer Concord Plant, Corning, Inc. c_ 0 DENRJDWQ FACT SHEET FOR NPDES PERMIT DEVELOPMENT NPDES No. NC0086169 Facility Information Applicant/Facility Name: Corning, Incorporated — Midland Facility Applicant Address: P.O. Box 1700, Concord, NC 28026-1700 Facility Address: 14556 Highway 601 South Permitted Flow 0.107 MGD currently requesting 0.142 MGD Type of Waste: 100% Industrial Facility/Permit Status: Active requesting major modification County: Cabarrus Miscellaneous Receiving Stream: UT Muddy Creek (001), UT Clear Creek (002), Rocky River (003) Regional Office: Mooresville G16NE/G17NW Stream Classification: C USGS Topo Quad: 303(d) Listed?: No Permit Writer: Michael Myers Subbasin: 03-07-12 Date: May 16, 2001 Drainage Area (mi2): NA • Summer 7Q 10 (cfs) 30 Winter 7Q10 (cfs): NA Average Flow (cfs): NA 1WC (%): 1.8 (at 0.142 MGD) Primary SIC Code: 3229 SUMMARY OF FACILITY AND WASTELOAD ALLOCATION Corning Incorporated manufactures optical fibers at its Midland facility in Cabarrus County. The facility originally received its National Pollutant Discharge Elimination System (NPDES) permit in 1998. Startup began late that year. The facility was issued a renewed NPDES permit on April 14, 2001, which included an expanded flow to 0.107 MGD. On December 19, 2000, the Division of Water Quality received a request for modification to the NPDES Permit, specifically, the facility requested a flow expansion from 0.107 MGD to 0.142 MGD. Wastewater generated includes sanitary wastewater, non -contact cooling wastewater, process wastewater, stormwater, filter backwash water and boiler blowdown. Currently, sanitary wastewater is treated off -site at the Muddy Creek Wastewater Treatment Plant. Wastewaters other than sanitary are treated and discharge through one of three outfalls as summarized below. Outfall 001 This discharge is comprised of 100% stormwater, collected in a stormwater detention pond. The receiving stream is an unnamed tributary of Muddy Creek. Currently, no effluent limitations and monitoring page is contained within the permit for this outfall, though stormwater controls are required. Special Condition A. (6.) of the permit addresses stormwater discharges and applicable monitoring requirements. This proposed modification would have no effect on the requirements for this outfall. Outfall 002 This discharge is comprised of stormwater and humidification boiler blowdown. Wastewater is collected in a stormwater detention pond prior to discharge into an unnamed tributary of Clear Creek. Effluent limitations and monitoring have been applied and stormwater controls are required (Special condition A. (6.) of the permit addresses stormwater discharges and applicable monitoring requirements). The proposed modification will have no effect on the permit for this discharge. Coming Fact Sheet NPDES Renewal Page 1 Outfall 003 This discharge is comprised of industrial process wastewater, non -contact cooling water, and carbon filter backwash water. These wastewaters are neutralized and treated using a solids removal unit prior discharge into the Rocky River. This proposal will increase industrial process and carbon filter backwash wastewater flow to 0.142 MGD and total flow to 0.334 MGD (per application). Note, from the above discussion, non -contact cooling water enters outfall 003 effluent line after the treatment facility. Under this proposal, approximately 192,000 gallons per day (gpd) of non -contact cooling water will be commingled with the process wastewater prior to discharge. The 0.142 MGD flow limit shall apply to the process wastewater and instream waste concentration used to determine the toxicity limit is based on the total flow (process + non -contact cooling water) discharged. The flow limit of 0.142 MGD, includes sum of the industrial process wastewater and the carbon filter backwash wastewater therefore, the compliance point for flow is upstream of the point at which non - contact cooling water is introduced. Though the flow limit includes only industrial process wastewater and carbon filter backwash wastewater, the toxicity testing limit has been established using an IWC calculation using the entire anticipated flow from outfall 003 (about 334,000 gpd). According to the priority pollutant analysis, the effluent discharged by the facility may contain chloroform, aluminum, arsenic, cadmium, chromium, copper, nickel, selenium, zinc, chloride and fluoride. The primary parameters of concern from outfall 003 (as indicated in Table 1) are chloride, cadmium, copper and zinc. These parameters are discussed below. Based on the Division's analysis this discharge does not pose a reasonable potential to cause an exceedence of the North Carolina's Chronic Aquatic Life Action Level Standard for chloride. However, the maximum predicted concentration using self -monitoring data is greater than the Criteria Maximum Concentration (CMC). A numerical limit is not included since chloride is an action level water quality standard and biomonitoring requirements are adequate to control toxicity due to chloride. Based on the Division's analysis this discharge does not pose a reasonable potential to cause an exceedence of the North Carolina's Chronic Aquatic Life Standard for cadmium. However, the maximum predicted concentration using the reported value in the annual pollutant analysis monitoring report is greater than the CMC. This analysis is based on one data point and an assumed coefficient of variation of 0.6. Though no limit is proposed a monitoring requirement has been added in order to gather sufficient data to evaluate this discharge. Based on the Division's analysis this discharge does not pose a reasonable potential to cause an exceedence of the North Carolina's Chronic Aquatic Life Action Level Standard for copper. However, the maximum predicted concentration and the result in the annual pollutant analysis monitoring report are greater than the CMC. Numerical limits for copper are not being included since copper is an action level water quality standard and the biomonitoring requirements are adequate to control toxicity due to the presence of copper in the facility effluent. The permittee may request that the Division reevaluate the monitoring requirement after seven data points have been collected over seven months. Based on the Division's analysis this discharge does pose a reasonable potential to cause an exceedence of the North Carolina's Chronic Aquatic Life Action Level Standard for zinc. Numerical limits for zinc are not being included since zinc is an action level water quality standard and the biomonitoring requirements are adequate to control toxicity due to the presence of zinc in the facility effluent. Though no limit is proposed, if the facility experiences chronic toxicity violations the discharge will be re- evaluated according to the Division's Action Level Policy. The permittee may request that the Division reevaluate the monitoring requirement after seven data points have been collected over seven months. Corning Fact Sheet NPDES Renewal Page 2 Table 1. Identified Pollutants of Concern with Maximum Predicted Concentrations. 1 2 based on Environmental Protection Agency (EPA) Chronic Aquatic Life Criterion. 3 based on an assumed Coefficient of Variation (CV) of 0.6, per Technical Support Document. 4 based on Reasonable Potential Analysis using the Technical Support Document methodology. Parameter Aquatic Life Chronic Allowable Concentration' Aquatic Life Half Final Acute Concentration Annual Pollutant Analysis Monitoring Result Maximum Predicted Effluent Concentration Aluminum 5128 µg/L2 750 µg/L 360 µg/L 4752 µg/L3 Arsenic 2947 µg/L 340 µg/L 25 µg/L 330 µg/L3 Cadmium 117.9 µg/L 15 µg/L 3.0 µg/L 39.6 µg/L3 Chromium 2947.4 µg/L 1022 µg/L 13 µg/L 171.6 µg/L3 Copper 412.6 µg/L 7.3 µg/L 13 µg/L 171.6 1.ig/L3 Nickel 1473.7 µg/L 261 µg/L 11 µg/L 145.2 µg/L3 Selenium 294.7 µg/L N/A 5.0 µg/L 66 µg/L3 Zinc 2947.4 µg/L 67 µg/L 864 µg/L 11404 1.1g/L3 Chloride 14737.2 mg/L 860 mg/L 9,500 mg/L 14442.2 mg/L4 Fluoride 106.1 mg/L N/A 2.09 mg/L 27.6 mg/L3 TOXICITY TESTING: Current Requirement: Proposed Requirement: Chronic P/F ® 1.0% at 0.107 MGD using Ceriodaphnia Chronic P/F 1.7% at 0.142 MGD using Ceriodaphnia The above IWCs were calculated using a flow equal to the sum of the permitted flow at outfall 003 and the non - contact cooling water contribution. This facility has passed all toxicity tests since startup. COMPLIANCE SUMMARY: The facility has been in compliance with its NPDES Permit. INSTREAM MONITORING: A benthic macroinvertebrate study was required in the original permit. That permit required the facility to complete a benthic survey during the summer of 1999. The study was completed in August and submitted to the Division for review. Dave Lenat of the Environmental Sciences Branch reviewed the study and provided the writer with comments. His conclusion were in agreement with the study results, which indicated no biological impact from this discharge. As the discharge will be expanding, the benthic survey requirement will be included with this renewal. Expansion is not expected to be complete until late 2003. As such, the draft permit will require a benthic study be completed during the summer of 2004. No other instream monitoring is required. PROPOSED CHANGES: Outfall 003 Flow Limit: The flow limit at outfall 003 has been modified in accordance with the facility's request. IWC for Outfall 003: The IWC has been updated to reflect the increase in permitted flow at outfall 003. See the Toxicity Testing portion of this report. Cadmium monitoring for outfall 003, see discussion above. Copper monitoring for outfall 003, see discussion above. Zinc monitoring for outfall 003, see discussion above. PROPOSED SCHEDULE FOR PERMIT ISSUANCE: braft Permit to Public Notice: May 16, 2001 Permit Scheduled to Issue: July 9, 2001 Corning Fact Sheet NPDES Renewal Page 3 STATE CONTACT: If you have any questions on any of the above information or on the attached permit, please contact Michael Myers at (919) 733-5038 ext. 508. NAME: NPDES SUPERVISOR: NAME: i,,Z_DATE: " /S; pip DATE: Corning Fact Sheet NPDES Renewal Page 4 REGIONAL OFFICE COMMENT: . Pc -k.— w ; // q. - 71 NAME: DATE: REGIONAL SUPERVISOR: NAME: DATE: Corning Fact Sheet NPDES Renewal Page 5 Whole Effluent Toxicity Testing Self -Monitoring Summary FACILITY REQUIREMENT April 19. 2001 YEAR JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC Comm Scope IneJ003 24hr LC50 ac monh epis tlhd (composite sampling) 1997 - - - - - - - - H - H - NC0034754/003 Begin:10/8/1997 Frequency: l/calQ 1/calendarQ NonComp: 1998 H H H - H H - - H H - e8 County: Catawba Region: MRO Subbasin: CTB32 1999 - - H - - H - -- H - - Bt PF: var Special 2000 -. - NR - - NR - - H - - H 7Q10: 0.0 11VC(%)na Order: 2001 - - Comm Scope Inc./004 24 hr LC50 ac monit epis fthd (composite sampling) 1997 - - - NC0034754/004 Begin:I0/8/1997 Frequency: !/calQ 1/calendar Q NonComp: 1998 - H H County: Catawba Region: MRO Subbasin: CT032 1999 - - H PF: var Special 2000 - - NR 7Q10: 0.0 IWC(%):na Order: 2001 - H H H 26.9 H - - H H H 96.9 H - -- H - Bt NR -- --- H -.- -- H Communications Instruments Inc Perm chr dim: 5.6%(Grob) 1997 - N NC0033227/004 Begin:7/1/1996 Frequency: Q P/F + Feb May Aug Nov + NonComp:Single 1998 - Pass County: Buncombe Region: ARO Subbasin: FRB02 1999 - Pass PF: 0.288 Special 2000 - Pass 7Q10: 7.5 IWC(%):5.6 Order. 2001 - Pass N Bt Bt Bt NRJBt Pass - - Pass NR Pass - Pass Fall >22 >22 Pass Pass Pass Pass Pass Pass Concord Rocky River W WTP Penn P-2 chr lim: 69%, once Q > 20 MGD, then 73% Emit (New Y 1997 - >99 - - >99 - >99 - 46.8 >99 NC0036269/001 Begin:7/1/1995 Frequency: Q Feb May Aug Nov + NonConlp:ChV Avg 1998 NR >99 - - >99 - - >99 --- - >99 - Counly Cabanus Region: MRO Subbasin: YAD12 1999 - >99 - >99 - - >99 -- -- >99 - PF: 20 Special 2000 - >99 - - 78.8 - - >99 >99 - 7Q10:14.0 IWC(%):69 Order: 2001 - >99 Cone Mills - Cllffslde Penn chr 1hn: 4.2% NC0004405/001 Begin:2/I/1999 Frequency: Q P/F + Jan Apr Jul Oct County: Rutherfonl Region: ARO Subbasin: BRD02 PF: 1.75 Special 7Q 10: 62.10 1 W C(%):4.1 9 order. + NonComp:Single 1997 Fail Pass 1998 Pass - 1999 Pass - 2000 Fall Fail 2001 Fell 2.5,>10 Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Cone Mills Greensboro-001 Perm chr lim: 79% Y 1997 48,14 >79 48 14 28 14 48 28 28 28 28 Late NC0000876/00I Begin:5/I/1998 Frequency: Q P/F + Mar Jun Sep Dec + NonComp:Single 1998 Late 48.2 68.2 68.3 28.1 68.3 28 28.1 14.1 48.2 28.1 >79 County: Guilford Region: WSRO Subbasin: CP1,02 1999 >79 et0 28 88.2 28 48 48 88 68 c10 28 14 PF: 1.25 Special 2000 28.1 28 Late 28.1 14.1 68.3 14.1 .10 14.1 48.3(s) 28.14) 28.1 7Q10: 0.5 IWC(%):79 Order. 2001 48.3 33.85(5) Conover NE W WTP Perm chr lim: 32%(New pens 1/1J2001) Y 1997 - - Pass - - Pass - Pass - - Pass NC0024252/001 Begin:6/1/1996 Frequency. Q P/F + Mar Jun Sep Dec + NonComp:Single 1998 - - Pass - - Pass - -- Pass - - Pass County Catawba Region: MRO Subbasin: CTB32 1999 - - Pass - - Pass - -- Late Pass - Pass PF: 1.5 Special 2000 - - Pass - -. Pass - -- Pass - - Pass 7Q10: 5.0 IWC(%):32.0 Order. 200t - Contentnea MSD PERM CHR LIM: I I%(New perm 2/1/2001) Y 1997 Pass - - Pass - Pass Pass NC00320771001 Begim5/1/1994 Frequency: Q P/F + Jan AprJulOct NonComp:SINGLE 1998 Late Late Pass Pass -- - Pass - Pass County: Pitt Region: WARO Subbasin: NEU07 1999 Pass - - Pass - - Pass -- Pass - PF: 2.85 Special 2000 Pass - - Pass - - Pass Late Pass 7Q10: 36.0 IWC(%):I 1 Order: 2001 Pass - Coolecmee W WTP PERM CHR LIM: 2.1 % Y 1997 Pass - - Pass - -- Pass Pass NC0024872/00I Begin:9/1/1994 Frequency: Q P/F + Jan Apr Jul Oct NonComp:SINGLE 1998 NR/Pass - Pass - Pass - Pass County: Davie Region: WSRO Subbasin: YADO6 1999 Pass - - Pass -- Pass -- - Pass PF: 1.5 Special 2000 Pa as - - Pass -- -- Pass -- -- Pass 7Q10:106 IWC(%):2.1 Order: 2001 Pass - -V Corning Inc. hlldland Fiber Facility Perm chr lim: 1.0% NC0086169/003 Begin:5/1/2000 Frequency: Q Jan Apr Jul Oct County Cabanas Region: MRO Subbasin: YAD12 PF: 0.107 Special 7Q10: 30 IWC(%):1.0 Order. + NonComp:Single 1997 - - - -. ... -- - -- - - 1998 - - - N -. N -- - N 1999 Pass - - Pass - -- NR/Pass -- -- Pass 2000 Pass - - Pass - - Pass --- Pass 2001 Pass - Pass Correa, Dept Of (Caledonia) Perm 24hr p/f ac dim: 90% Rhd NC0027626/001 Begim10/I/1997 Frequency:Q + Jan Apr Jul Oct County: Halifax Region: RRO Subbasin: ROA08 PF: 0.8 Special 7QI0: 1000 IWC(%):0.12 Order: + NonComp:Single 1997 Pass - - Pass - - Pass - - Pass 1998 Pass - Pass - - Pass - - Pass 1999 Pass - - Pass - - Pass - - at 2000 Bt - Pass Pass -- Pass 2001 Pass - Y Pre 1997 Data Available LEGEND: PERM - Permit Requirement LET= Administrative Letter - Target Frequency = Monitoring frequency. Q- Quarterly; M. Monthly; BM- Bimonthly, SA- Semiannually; A- Annually; OWD- Only when discharging; D- Discontinued monitoring requirement Begin = First month required 7Q10 = Receiving stream low flow criterion (cfs) 4 = quarterly monitoring increases to monthly upon failure or NR Months that testing must occur - ex. Jan, Apr, Jul, Oct NonComp = Current Compliance Requirement PF = Permitted flow (MGD) IWC%=lnstream waste concentration P/F = Pass/Fail test AC Acute CHR = Chronic Data Notation: f - Fathead Minnow; • - Ceriodaphnia sp.; my - Mysid shrimp; ChV - Chronic value; P - Mortality of stated percentage at highest concentration; at - Performed by DWQ Aquatic Tox Unit; bt - Bad test Reporting Notation: -- - Data not required; NR - Not reported Facility Activity Status: I - Inactive, N - Newly Issued(To construct); H - Active but not discharging;! -Mott data available for month in question; • = ORC signature needed 13 Facility Name = NPDES # = Qw (MGD) = 7Q10s (cfs) = IWC (%) = Corning Inc. - Midland NC0086169 0.334 30 1.70 FINAL RESULTS Chloride Max. Pred Cw Allowable Cw Allowable #/day 14442.24759 14737.2 41051.23 RESULTS Std Dev. Mean C.V. Number of data points Mull Factor = Max. Value Max. Pred Cw Allowable Cw Allowable #/day 1553.299626 8259 0.188077169 15 1.37 10529.0 mg/L 14442.25 mg/L 14737.2 mg/L 41051.23 #/day Parameter = Standard = Chloride 250.0 Date n < BDL=1/2DL Actual Data 1 10529.0 10529 2 9236.3 9236.25 3 8595.4 8595.38 4 8614.0 8614 5 8614.0 8614 6 9007.0 9007 7 9375.0 9375 8 7733.0 7733 9 5770.0 5770 10 5394.0 5394 11 5638.0 5638 12 7472.5 7472.5 13 9352.5 9352.5 14 9460.0 9460 15 9092.0 9092 mg/L Facility Name = NPDES # = Qw (MGD) = 7Q10s (cfs) = IWC (%) = Corning Inc. - Midland NC0086169 0.334 30 1.70 Iron Max. Pred Cw Allowable Cw FINAL RESULTS 2.154166935 58948.6 RESULTS Std Dev. Mean C.V. Number of data points Mult Factor = Max. Value Max. Pred Cw Allowable Cw 0.229809175 1.0 0.22834775 15 1.47 1.5 µg/1 2.154166935 µg/1 58948.6 µg/1 Parameter = Standard = Iron 1000.0 Date n < BDL =1 /2DL Actual Data 1 1.3 1.333 2 1.1 1.08 3 1.0 1 4 1.0 0.98 5 1.2 1.175 6 1.0 1 7 0.7 0.704 8 1.0 1.034 9 0.8 0.77 10 0.7 0.74 11 0.8 0.75 12 1.5 1.47 13 0.8 0.77 14 1.2 1.19 15 1.1 1.1 4 ,,.,,,,p 0 . coao7f tJGo°04Y96, v-kr' --�• To: Permits and Engineering Unit Water Quality Section Attention: Mike Myers SOC PRIORITY PROJECT: No Date: May 18, 2001 NPDES STAFF REPORT AND RECOMMENDATIONS County: Cabarrus NPDES Permit No.: NC0086169 (Modification) MRO No.: 01-06 PART I - GENERAL INFORMATION 1. Facility and address: Corning, Inc. Post Office Box 1700 Y.AY 2 4 2001 Concord, N.C. 28026-1700 C hR - WATER QUALITY 2. Date of investigation: N/A f U ' T SOURCE BRANCH 3. Report prepared by: Michael L. Parker, Environmental Engineer II 4. Person contacted and telephone number: Christie Hannan, (704) 569-6268. 5. Directions to site: From the jct. of Hwy. 601 and Hwy. 24-27 in the Town of Midland in southern Cabarrus County, travel south on Hwy. 601 2.65 miles. The Corning plant is located on the right (west) side of Hwy. 601. 6. Discharge point(s), List for all discharge points: - outfall 001 Latitude: 35 ° 13' 02" Longitude: 80 ° 31' 15" outfall 002 35 ° 12' 34" 80° 31' 31" outfall 003 35° 12' 30" 80° 29' 49" Attach a USGS Map Extract and indicate treatment plant site and discharge point on map. USGS Quad No.: G 16 NE 7. Site size and expansion area consistent with application: Yes. There is sufficient area available for the construction of any proposed treatment units. 8. Topography (relationship to flood plain included): Relatively flat, 2-4% slopes. The plant site is not located in a flood plain. 9. Location of nearest dwelling: Approx. 500+ feet from the WWTP site. Page Two 10. Receiving stream or affected surface waters: U.T. to Muddy Creek (outfall 001), U.T. to Clear Creek (outfall 002), Rocky River (outfall 003). a. Classification: C (for all outfalls) b. River Basin and Subbasin No.: Yadkin 030712 c. Describe receiving stream features and pertinent downstream uses: Little, if any flow noted at the discharge locations for outfalls 001 and 002 (dry ditch). Excellent flow observed in the Rocky River at outfall 003. PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater: 0.269 MGD (outfalls 001 & 002), 0.147 MGD* (outfall 003) *New flow figure based on current modification request. Outfall 001 contains the following types of wastewater: 1. Stormwater. Outfall 002 contains the following types of wastewater: 1. Stormwater 2. Humidification boiler blowdown Outfall 003 contains the following types of wastewater: 1. Blowdown from pollution abatement equipment. 2. Water softener from area floor drains. 3. Water softener blowdown. 4. Cooling tower blowdown. 5. Some stormwater b. What is the current permitted capacity: N/A c. Actual treatment capacity of current facility (current design capacity): N/A d. Date(s) and construction activities allowed by previous ATCs issued in the previous two years: N/A e. Description of existing or substantially constructed WWT facilities: The existing WWT facilities consist of a 21,000-gallon equalization tank followed by two off - spec tanks (36,000 and 21,000-gallon), two (2) Lamella clarifiers, a 60,000-gallon chloride stabilization tank, four (4) 1,600-gallon pH adjustment tanks, a 10,000- gallon softener regenerate tank, a neutralization transfer tank, 21,000-gallon surge/blend tank, three (3) sludge thickening tanks (575, 5,000 and 10,000- gallon), an effluent lift station, a 42,000-gallon process effluent tank (for storage of wastewater when quality does not meet permit limits) and flow measurement. Page Three f. Description of proposed WWT facilities: No additional facilities are proposed. Modification request is for an increase in flow only. g• Possible toxic impacts to surface waters: Chlorides are present in the waste stream. h. Pretreatment Program (POTWs only): Not Needed. 2. Residual handling and utilization/disposal scheme: Current residuals disposal scheme involves thickening and storage in a residuals holding tank. The residuals are then pumped into drums where they are transported to Michigan for further treatment, and then landfilled. 3. Treatment plant classification: Class III (based on current treatment processes). 4. SIC Code(s): 3357 Wastewater Code(s): 73, 16 5. MTU Code(s): 51012 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only)? No 2. Special monitoring or limitations (including toxicity) requests: None at this time. 3. Important SOC/JOC or Compliance Schedule dates: N/A 4. Alternative analysis evaluation: a. Spray Irrigation: Generally poor soils in the vicinity of the plant site. Insufficient area available for the construction of a spray irrigation WWT system. b. Connect to regional sewer system: Corning currently discharges all domestic wastewater into the Water and Sewer Authority of Cabarrus County's Muddy Creek WWTP. There is currently insufficient capacity at the Muddy Creek WWTP to accept all of Corning's waste streams. c. Subsurface: Insufficient area, poor soils. Page Four PART IV - EVALUATION AND RECOMMENDATIONS Corning, Inc. requests a modification to the subject NPDES Permit for an increase in the permitted flow at outfa11 003. The current permitted flow is 0.107 MGD and Corning requests approval to increase this flow to 0.142 MGD. No additional treatment components are proposed for this modification. Pending a technical review of this request by the NPDES Unit, it is recommended that the request for an increase in flow at outfall 003 be approved as requested. Signature of Report Preparer Date ‘647Jew--N Water Quality Re al Sup ervisor Q ty _ ate h:ldsrldsrO11corning.sr Corning Incorporated Telecommunications Products Division P.O. Box 1700 Concord, North Carolina 28026-1700 7�4-169-6000 December 2000 Mr. David A. Goodrich North Carolina Department of Environment and Natural Resources Division of Water Quality, NPDES Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: NPDES Permit Modification Request for Coming's Midland Facility; NPDES Permit No. NC0086169 — Coming, Incorporated; Cabarrus County Dear Mr. Goodrich: CORNING Coming, Incorporated is planning a second expansion of its fiber optic manufacturing facility in Cabarrus County. To accommodate this expansion, Corning is hereby requesting modification to its NPDES permit, issued on December 4, 2000. Specifically, Corning requests an increase in the permitted flow for its process wastewater outfall, designated outfall 003, from 0.107 MGD to 0.142 MGD. Furthermore, as the increased production associated with this expansion is not expected to be realized until 2002, Corning requests that effluent limitations associated with a 0.142 MGD flow tier not be implemented until July 1, 2002. Details of the proposed expansion are summarized in the attached permit application documents. We are operating under strict time constraints with respect to this expansion. We appreciate the hard work of your staff and respectfully request receipt of the requested permit modification by June 2001. Additionally, we will be submitting our request for Authorization to Construct (ATC) by the end of January 2001 and request that the ATC be issued concurrently with the permit modification if at all possible. We look forward to meeting with you in January to discuss this and other issues. Thank you for your consideration of our request. If you should have any questions during your review or need additional information, please don't hesitate to contact me at (704) 569-6268. Sincerely, Christy L. Hannan Environmental Control Engineer Coming, Inc. Enclosures cc: Blake Manuel, Coming, Inc., Corporate Environmental Group i-caTY-G,1 DEC 19 2000 L DEER - WATER QUALITY POINT SOURCE BRANCH Corning, Incorporated Midland Waveguide Facility Cabarrus County, North Carolina SUMMARY Corning, Incorporated manufactures optical fiber at its Cabarrus County facility in Midland, North Carolina. The facility operates the following NPDES permitted outfalls: • Outfall 001: Stormwater discharge from detention pond to an unnamed tributary to Muddy Creek. • Outfall 002: Discharge of stormwater and humidification boiler blowdown from South Stormwater Management Pond to an unnamed tributary to Clear Creek. • Outfall 003: Discharge of process wastewater and other non -process wastewater such as non -contact cooling water to the Rocky River. Process wastewater is generated from wet scrubbers used for air pollution abatement. Outfalls 002 and 003 have analytical monitoring requirements while outfalls 001 and 002 are regulated by the stormwater portion of permit number NC0086169. Originally permitted in 1997, Corning requested a permit modification with its renewal in April of 1999 for an increase of flow to accommodate a manufacturing expansion, dubbed Concord II. This expansion increased the permitted flow for outfall 003 from 0.0274 MGD to 0.107 MGD. The current expansion request, dubbed Concord III, will increase the permitted flow for 003 from 0.107 MGD to 0.142 MGD. It should be noted that although non -contact cooling water and process wastewater are commingled prior to discharge, the compliance point for flow at outfall 003 is, and should continue to be, upstream of the confluence of these two streams and is meant to measure only the process wastewater contribution. The chronic toxicity test percentage is based on the commingled flow, approximately 0.33 MGD after expansion. WASTEWATER TREATMENT (See Figures 1— 3 as well as Attachment A) In general terms, the Pollution Abatement Neutralization System collects all potentially contaminated wastewater streams from the plan and provides unit operations for treating those streams to the parameters provided in the NPDES permit so they can be discharged to the Rocky River. The Neutralization System consists of two separate, yet interconnected, operations; Neutralization System No. 1 and Neutralization System No. 2. Neutralization System No. 1 (also referred to as the "existing" system or "NEUT 1") will continue current operations with the following exceptions: timt 1. Non -contact cooling water blowdown from the Concord I utility area will be piped to Neutralization System No. 2 for treatment prior to discharge; 2. The treated effluent from the Neutralization Transfer Tank will be Piped to Neutralization System No. 2 for suspended solids removal; and 3. All softener regeneration wastewater will be treated in Neutralization System No. 2. The existing cooling tower filters will be taken out of service and the filter backwash will no longer flow to Off -Spec Tank No. l . Neutralization System No. 2 collects wastewater from the Concord II Phase 1 and Phase 2 scrubbers and any contaminated stormwater from the secondary containments, equalizes hydraulic surges and chemical concentrations, removes suspended solids from the wastewater, neutralizes wastewater to required levels, re -treats any off -spec wastewater, and discharges the treated wastewater to the river. Treated effluent from Neutralization System No. 1 is pumped to the Surge/Blend Tank in Neutralization System No. 2. Non -contact cooling water and softener regeneration wastewater from the existing plant and expansion utility areas are piped to the Surge/Blend Tank in Neutralization System No. 2 to be treated prior to discharge. Neutralization System No. 2 is included as part of the Concord plant expansion project. This system consists of three distinct unit operations. Acid Cleaning Unit The first operation consists of a system to collect and remove suspended solids from Concord II and III HC1 scrubber blowdown. In normal operation, the blowdown from Concord II and III HC1 scrubbers is pumped in batch mode (8 — 20% HC1) to Lamella No. 2 Head Tank. This tanks serves to equalize flow surges and allows a constant feed to Lamella Separator No. 2. In this lamella a flocculant is added and any suspended solids present in the scrubber blowdown are removed. Treated effluent from this lamella is pumped to the Chloride Stabilization Tank and is then pumped at a constant flow rate to Equalization Tank No. 2. Solids are intermittently removed from the lamella and transferred to Sludge Thickening Tank No. 2. Figure 1—Acid Cleaning Unit Lamella head Tank; 3,000 gallons Flocculant Lamella Separator No. 2 Sludge to Thickening Tank No. 2 Chloride Stabilization Tank 60,000 gallons Transfer Tank 400 gallons Neutralization Unit The second operation is a two stage neutralization system for treating acid and/or caustic scrubber blowdown. Acid from the Chloride Stabilization Tank and blowdown from the Concord II and Concord III Core Chlorine and Consolidation Chlorine scrubbers are collected in Equalization Tank No. 2. The combined scrubber blowdown is pumped to pH Adjustment Tank No. 3 and flow by gravity to pH Adjustment Tank No. 4. Any off -spec (pH) wastewater is automatically diverted to Off -Spec Tank No. 2 from pH Adjustment Tank No. 4 and then pumped back to Equalization Tank No. 2 at a controlled rate for re - treatment. The pH adjusted effluent is pumped to the Surge/Blend Tank. Figure 2 — Neutralization Unit Chloride Stabilization Tank Core Chlorine Scrubbers Consolidation Chlorine Scrubbers Off -Spec Tank No. 2 NaOH or HC1 NaOH or HC1 i i Sodium Bisulfite (NaHSO3) Equalization Tank o] No. 2 21,000 gallons 1 pH Adjustment Tank No. 3 1,700 gallons '• pH Adjustment Tank No. 4 1,700 gallons Surge/Blend Tank Off -Spec Tank if out of control range ► or Solids Removal Unit The third system collects all cooling tower blowdown, all neutralization system effluents, and softener regeneration wastewater for a final polishing step to remove suspended solids. The inlet header to the Surge/Blend Tank provides for pre -mixing of non -contact cooling tower blowdown, treated effluent from Neutralization System No. 1, treated effluent from Neutralization No. 2, and softener regeneration wastewater prior to entering the tank. This provides for thorough mixing of the wastewater inlet flows and sodium bisulfite for chlorine removal in a static mixer. From the Surge/Blend Tank the blended wastewater is pumped to Lamella Separator No. 3 for removal of suspended solids and is then pumped to the existing Effluent Lift Station. Any off -spec (pH) wastewater is automatically diverted to Off -Spec Tank No. 2 and then pumped back to Equalization Tank No. 2 at a controlled rate for re -treatment. The Lamella Head Tank, Lamella Separator No. 2, Equalization Tank No. 2, pH Adjustment Tanks, Neutralization Transfer Tank No. 2, and Off -Spec Tank No. 2 are vented to the existing Miscellaneous Scrubbers for collection and treatment of any vent vapors. An existing Process Effluent Tank is located at the Effluent Lift Station for storage of wastewater during the times wastewater cannot be pumped to the river. Wastewater stored in the Process Effluent Tank is returned, by gravity, to the Effluent Lift Station. Settled Solids in the Lamella Separator are periodically pumped from the lamella to Sludge Thickening Tank No. 3 and then to the existing Sludge Holding Tank for disposal. Figure 3 — Solids Removal Unit Neut. System No. 1 & Concord I Cooling Tower Blowdown Softener Regeneration Tank Lamella No. 3 Transfer Pumps Concord II & Concord III Cooling Tower Blowdown Neutralization Transfer Pumps No. 3 & 4 Sodium Bisulfite (NaHSO3) Surge/Blend Tank 21,000 gallons Static Mixer L300000000C Coagulant Lamella Separator No. 3 Lamella No. 3 Transfer Tank 800 gallons Flocculant Sludge Thickening Tank No. Effluent Lift Station Surge/Blend Tank if out of control range ► or Corning, Inc. Existing Concord Plant plus Expansion (..] ,Water Inflows Item/user Daily average flow (GPM) Daily Average Flow (GPD) Potable Water Humidification Boiler HVAC Cooling Towers ECWS Cooling Towers HCI & Cl2 Scrubbers Consolidation Scrubber Systems Miscellaneous Scrubber Systems Chemical Reagent System Spray Coolers Pump Seal Water (Note 5) Water Softener Regeneration 31 44,640 40 57,600 458 659,520 28 40,320 40 57,600 7 10,080 2 2,880 70 100,800 62 89,280 5 7,200 6 8,640 Total 749.0 1,078,560 Water Outflows Item/User Daily Average Flow (GPM) Daily Average Flow (GPD) Sanitary Sewer Humidification Boiler - Steam Humidification Boiler - Blowdown HVAC Cooling Towers - Evaporation (Note 1) HVAC Cooling Towers - Blowdown (Note 2) ECWS Cooling Towers - Evaporation (Note 1) ECWS Cooling Towers - Blowdown (Note 2) HCI & Cl2 Scrubbers - Evaporation Consolidation Scrubber Systems - Evaporation Miscellaneous Scrubber Systems - Evaporation Total Waste Treatment System Flow (Note 3) Total Flow to Outfall DSN003 (Note 4) Spray Cooler Evaporation Total 31 44,640 36.8 52,992 3.2 4,608 336 483,840 123 177,120 18 25,920 10 14,400 25 36,000 5 7,200 1 1,440 98 141,120 231 332,640 62 89,280 749.0 1,078,560 Notes: 1) Evaporation is 1 % based on 10 °F delta T. 2) Blowdown rate is based on 4 cycles of concentration. 3) Includes Neutralization and Softener Regeneration 4) Total DSN003 is combined flow from waste treatment and blowdown from cooling towers. 5) Soft Water used for pump seals is included in the scrubber system flows. , Per-flow.xls 12/15/2000 „OFF -SPEC WASTE WATER CII HCL SCRUBBERS C11I HCL SCRUBBERS SOFTENER REGEN 7.8 GPM 3.1 GPM OFF SPEC TANK N0.1 24000 GAL 0 GPM REJECT ACIO TANK 10,000 GAL FLOC 10.9 GPM DECANT LAMELLA SEPARATOR N0.2 ICI HCL SCRUBBERS 5.0 GPM ,CI CL2 SCRUBBERS 5.4 GPM 10 GPM 0 GPM EQUALIZATION TANK N0.1 10,000 GAL COAGULANT & FLOCCULANT 20.4 GPM 0 GPM DECANT LAM LLA SEPARATOR N0.1 SLUDGE THICKENING TANK N0.1 575 GAL CAUSTIC 10 GPM 20.4 GPM SLUOGE pH ADJUSTMENT TANKS NO. 1 & 2 1600 GAL EACH 30.4 GPM 10.9GPM CHLORIDE 0 GPM • —�—� STABILIZATION 1 10.9 GPM 1 TANK 60,000 GAL �~ SOFTENER REGENERANT TANK 10,000 GAL ► 5.6 GPM CI. CII. & CIII ,COOLING TOWER SLOWDOWN 133 GPM SLUDGE THICKENING TANK NO.2 10,000 GAL ?OFF -SPEC WASTE WATER SLUDGE cil CL2 SCRUBBERS 11.6 (GPM* CIII CL2 SCRUBBERS 5.5 GPM OFF SPEC TANK N0.2 36,000 GAL 30 GPM 43.7GPM EOUALIZATION TANK NO.2 21.000 GAL ,32 CAUSTIC 20% CAUSTIC 61.7 GPM SALEABLE ACID TANK 60,000 GAL 0.3 GPM pH ADJUSTMENT TANKS N0.3 & 4 1600 GAL EACH SLUDGE HOLDING TANK 350 GAL 62 GPM 30.4 GPM SURGE/BLEND TANK 21,000 GAL ,,COAGULANT & FLOCCULANT 231 GPM REFERENCE OWG.NO. DESCRIPTION CECANT LAMELLA SEPARATOR N0.3 231 GPM i SLUOGE THICKENING TANK N0.3 5.000 GAL SLUDGE PROCESS EFFLUENT PUMPS 231 GPM TO OFF -SITE REUSE SLUOGE TO REGULATED LAWN,. TO ROCKY RIVER PROCESS EFFLUENT TANK. 42,000 GAL RELEASED FOR PERMIT APPLICATION REYIStc DESCRIPTION BY/GATE CHK/OATE APPY'D/OOTE LEGEND: NORMAL C1 - CONCORD I CD - CONCORD II CHI - CONCORD III CORNING CORNING INCORPORATED OPTICAL FIBER DIVISION PROPRIETARY Washington 100 Corpora. Porkwvy 9k0Y,phorn. AL 35242-29R Contract 79950.001 DESIGN BY. JOE UPCHURCH SIGNATURE ORAWN BY, T.L.80GG DRAWING TITLE SCHEMATIC OF PROCESS WASTEWATER TREATMENT CORNING INCORPORATED CABARRUS COUNTY CHECKED BY APPROVED BY. DATE SUBMITTED BY: DATE 11-16-00 SCALE NONE CONCORD III PROJECT CONCORD, N.C. CAO FILE NO. .1‘169.d.5 DRAWING NUMBER 17211- SK-169 -A u•SINSII,ILTIWNE.... •.,WIEIT6E.u. 44,0ESIDULCsSKC15134110N... ...4KEMY[u. RCITY VATtR FIRE VATER FOR E+ RE2;ICY USES ONLY POTABLE VATER STORAGE POTABLE VATER SYSTEM IU40IFICATIdl BOILER MC COMING Alm eSTORK PATER FOE PATER STORAGE ReFERERC! OHO.1c. DESCRIPTION SCETEIER SYS ECVS COOLING TOWER SCRUBBER SYSTEMS BLOw0OVN SYYSSTE REAGENT MISCELLNEOUS SCRUBBER SYSTEMS I EU LItTIDI SYS r Cd60L10AT10R SCRUBBER SYSTEM SOLIDS K BLOMOOYN TO OUTFN.L 09�Al2 SANITARY SEVER SFAN EYAPORAT! I* PROCESS irASTEVATER TO LUTFN.L OSNeme N3ATTE ENT AREA UTILITIES SPINY COOLERS SITARWEN SYST EYAPORATfOIe €YAPCFATION EYQPOINTION OUTFALL DSNBRIa OUTFALL CORNING CORNING INCORPORATED OPTICAL FIBER OIYISION PROPRIETARY SIGNATURE Washington Priam/ 4 OcaTNO T9960.001 ;ECM BYt JCE IPCMURC I \DMAN BYs T.L.IDEN9 CHECKED Bn DRAWING TITLE SCHEMATIC OF WATER FLOW CORNING INCORPORATED CABARRUS COUNTY APPROVED BY, SUBMITTED BYN CONCORD III PROJECT CONCORD, N.C. RELEASE° FOR PERMIT APPLICATION IESCRIPTINI INMATE awoATE ~Om DATE °Att I14B•M I..! PO( 'CAD FILE IN. Nkd 41.6.1 DRAWING NIEIBER 17211- SK-168 -A Corning, Inc., Midland Facility — NC0086169 — Cabarrus County Outfall 001 — Stormwater to UT to Muddy Creek; Lat: 35°13'02" Long: 80°31'15" Outfall 002 — Stormwater & Humidification Boiler Blowdown to UT to Clear Creek; Lat: 35°12'34" Long: 80°31'31" USGS Midland Quad Corning, Inc., Midland Facility — NC0086169 — Cabarrus County Outfall 003 — Process Wastewater to Rocky River; Lat: 35° 12' 10" Long: 80°29'49" USGS Stanfield Quad PLANT NDRIH i i! iE ' •., PROPERTY LINE ! 1 ' �.�•� WASTE STORAGE AREA i W • r, r •.�;�. ,. ' r. G r �. r -- r IR �! ..F 1 SEDIMENT t 1 r • 0• - L' TRAP N0. 4 •�• rrSl.,!r*/1!'''!fiFr!ra i i� F*. �;.�i*,' 1 / • r,. �.J i i �1 + Jam. Y :c s"i i`�rJ ,r,,1,r� 1 O �.�.�.�.�.�..s.......r. ;rr,1�Pl, l*.ry', •,..1 5...Ke i,%,4:44i.S�,l!f*i'�I'CIS. . .. .._._.._.._.-` � ; ��r �:+r v' r'vr"r• 1 i r.� r�F�r, r.. •,.�*'��r�l��� < i� f�.r.r.�.�.�.r.r..� ��,I�cr/.r.6rc2�.:*Oic°11 r��' i r.._.._.._.._.._.._..-% 1.[ pf•1ai!� Trprr EXISTING �•�,��y1 VJ' �r' �'' j ri!.��'�ay1'..;+���,P1I�*I�IJ;1�iACCESS!!!!!!!!!!::711:Te; �rJ�',;1.�! ��T'S��y.I r! ''�'r�.l1! 4***4�,;:RDAD1 •.M9!F!r!4?S�rr'"Mi .rb!',r,�i:�'�'Wo21EyAREAj• 't'!� *'1���r �,, r JCONTRACTOR ;SEDIMENT BASIN M,R!* .s.,r.,rC.�,�^, r T1iI"ri+»irlly✓d*iS+>R+e+1! / ! TRAILER 1 t r PROPERTY LINE AREA 71r fj'.� i �1 PROPERTY LINES { 1 .../ `• • • REFERENCE DWG. NO. DESCRIPTION j DROP FF PARKING 1 I11 Il 4 � � I 1 11 1 1 I 1 I I 1 I ii 1 SEDINENT ! /f i TRAP NO. 2 ;�� SEDIMENT TRAP NO. I ifsr • �.�r.r.r..r.r,•,.. �. r HOUSE ,, STORM I� WATER 1' MANAGEMENT; II : i1 POND / 'Il STORM WATER MANAGEMENT POND Ii •� !iu• _T. •'_ r--_-_•_•_-_•-•_- DRAINAGE• '''�*-.......,.,..........., _ BOUNDARY if•' 1/2' O• 1" {IIIIIIII GRAPHIC SCALE a ' • I "11=EAl • 1- I11 • r1T� ::I Ammi-._. MI •at• firr:�E'i�IPi •�:..L� 1 II L L yyljp 1 • i1U.-:: ALL" I 61dPL4EE' 71) •f P(Q1p�IKI Y� 'icy +aa BOUNDARY AREA .•• i E i nwnrna BOUNDARY AREA i� E� ; 5 LEGEND PROCESS LIFTLSTATION li •\ ,.H • \ , r ii EXISTING PAVED ROAD NEW PAVED ROAD GRAVELA ROAD NEW CONCRETE DRAINAGE AREA BOUNDARY PROPERTY LINE SaRTHT EDIMENT BASIN DSNO02 ' • ;. NORTHEAST -^SEDIMENT BASIN i s 1 i h-.-i ;; i SEDIMENT TRAP NO. PRELIMINARY NOT FOR CONSTRUCTION RELEASED FO1 PERMITTING PURPOSES ONLY Issue No. Ong CORNING CORNING INCORPORATED OPTICAL FIBER DIVISION PROPRIETARY RE v1510n DESCRIPTION 1 BY/DATE 0 Washington 100 Camara, Parkway l M#Qh.m, AL 36242-292L, Contract 79950,001 DESIGN BY: SIGNATURE DRAWN BYL DRAWING TITLE SITE/YARD SITE DRAINAGE PLAN CHECKED BY, APPROVED BY. DATE SUBMITTED BY, DATE 1 SCALE 1'-200' CONCORD III PROJECT CONCORD, N.C. CAO FILE NO. 0026Iy.99n DRAWING NUMBER 17211-00261-Y1332-4 ••NIE,TMLTIEIIS•.•• •l e•0•TEETIK•••• .•.LESIOIWILE•YECIFICA11011..L •...YSEL,WE..•, PLANT NORTH E AM E 12 12. REFERENCE 014. NO. DESCRIPTION '- ••••—•• / tf /,) X j I / NKr?. 61, "•%•• N•iN\ , N),_'0•ST:SINn %* N• • • ‘: • ,‘, - ‘•\-. - - •144 \ .34' • • Pe'' • lc •1 Or L:t ckt. • „: 4a-241144Kg==Hig: • 1% A •N kik*. k\\.N. • No. -0. • Nt•MTW2*. Nvaattit4m, --,Z-1•41.`,1 VS5MWMATTP-T.4....S",% - .Tka 1/2El• 1' GRAPHIC SCALE RSTPSION Ct SCRIPT ION - . BY/DATE CHK/DATE !APPV'El/OATE SIGNATURE DATE INVIBASItl BSN-002 - :SEDIMENT BASIN wa: PRELIMINARY NOT FOR CONSTRUCTION RELEASED FM PERMITTING PuRPOSES COLT Issue No. 00Zo CORNING CORNING INCORPORATED OPTICAL FIBER DIVISION PROPRIETARY Washington MO COMOritle Parkway laInninahan.AL 352,12-2028 Contract 79950.001 DESIGN BYt DRAWN BY. CHECKED. BY. APPROVED BY. SUBMITTED BY: DATE I SCALE 1,200' CAO FILE NO. 002719.dgn DRAWING TITLE SITE/YARD MASTER DRAINAGE PLAN CONCORD III PROJECT CONCORD, N.C. DRAWING NUMBER 17211-0027I-Y1332-A weswawaatials•••• aawarifttracs..• •••CESIOWILEISPICIFICATIONIII Z PLANT NORTH E 10BB0 E NAN E 11201 =l • i • . -„-515' 5,1'-- ' I =5N• •FAaN, - i I i�/• •50• _ y • 42' RCP O 0.50Y. GR. --- ��';I; • ' 'x__ - Ai- :• 1 " .'. 1'_ :1 11I1,1 l: ''� "I;;,,fl, STORM WATER MANAGEMENT POND. —5N N 3077.20 •'' E 10E57.60 EL.505.50 I • 1 }I r ,4: I i '" 22 E11O46.225 • , , EL. 505.50 • p f, yy sea .5� I'I 1 1 1 ( 1i I, C or WE mkt OEL:511 1 1 ;; s'+ :51 sn :...1.‘ .; il;= .. ---) '' 1 3 II.,�' '-;----4'-- 1•, '1 n I'• '1',;:i / \ I, ' .1, ',. • _:1.,,.y \ ,1, ., I'. , , , I \ I. . 1 ', .'�. /----- ; - r'1 ;.,.I REFERENCE ONG. NO. DESCRIPTION II 1/2' 0• 1' LlllllllfI GRAPHIC SCALE ,'1r J,1;;!:i NOTES: I. FOR GENERAL NOTES.LEGEND & ADDRREYIATId6 REFERENCE OWG.17211.00031-01332. 2 EX1STING TFE CIIGINAI. DWT IS TO FENDED FROM COITCLRS T AS SHOWN di iS PDC 10 DRAWING. ME FORD IS ALSO TO BE MIMED AS SHOWN. EL.511.00 NEYISION DESCRIPTION BY/GATE CHK/DATE SIGNATURE PRELIMINARY NOT FOR CONSTRUCTION RELEASED KR PERMITTING SOLY Issue Na Oats - CORNING CORNING INCORPORATED OPTICAL FIBER DIVISION PROPRIETARY 0 Washington Birmingham. 'AL 2 .try-292B Contract 79950.001 DESIGN BY: DRAWN BY: DRAWING TITLE SITE/YARD SOUTH DETENTION BASIN LAYOUT PLAN CHECKED BY: APPROVED BY: DATE SUBMITTED BY: DATE SCALE 1••30'-0' CA0 FILE N0. 00281y.d„g CONCORD III PROJECT CONCORD, N.C. DRAWING NUMBER 17211-00281-Y1332-A Su.IMIRXCTIONS...S ...01,IC•TRE.... ...OESIC.WFILE.SIECIFIC.TIM... ....YS 11.Ces. • Corning Incorporated Telecommunications Products Division P.O. Box 1700 Concord, North Carolina 28026-1700 704-569-6000 CORNING April 3, 2000 CERTIFIED MAIL RETURN RECEIPT REQUESTED ATTN: Central Files Division of Environmental Management North Carolina Department of Environment and Natural Resources PO Box 29535 Raleigh, North Carolina 27626 To Whom it May Concern: Per NPDES Permit No. NC0086169, Corning, Inc., Concord, North Carolina is submitting an Annual Pollutant Analysis. Enclosed are two copies of the Annual Pollutant Analysis Monitoring (APAM) Requirement Reporting Form A. Thank -you for your assistance. If you require additional information, please contact me at (704) 569-6268. Sincerely, Christy L. Hannan Environmental Control Engineer Corning, Inc. Concord Plant Annual Pollutant Analysis Monitoring Requirement Reporting Form A (Revised June 1990) Facility Information: Page 1 of 9 NPDES Permit No: NC0086169 Discharge (Pipe) No: 001 Year: 2000 Facility Name: Corning Incorporated Class: County: Cabarrus Person(s) Collecting Samples: .laime Ritchie Status of facility wastewater treatment operation on day of sampling: typical: = Yes No If no, explain briefly: Analytical Laboratory: Research & Analytical Laboratories , Inc . II. Sampling 24 hr composite for main sample / grab sample for purgeable fraction Date Sampled: (composite sample) Corresponding sample taken for toxicity testing: Sampling begun (date,time): 02/23/00 - 0930 Yes Sampling finished (date,time): 02/24/00 - 0930 —� No Date and time sampled (grab sample): 0 2/ 2 4/ 0 0 - 0930 Instructions The purpose of this document and the accompanying memo is to standardize the sampling, analysis and reporting procedures to be used the Annual Pollutant Analysis Monitoring (APAM) Requirement as described in the permit. Sampling 1 - Take a 24-hour composite sample from the final effluent during mid -week (Wednesday through Friday). Collect a grab -sample for the vole. organic fraction when collection of the 24-hour composite sample is completed. Follow any other sampling instructions provided by the laborat performing the analysis. 2 - Indicate in the space provided at the top of this page whether a corresponding sample for toxicity was taken. 3 - Make Note of any unusual wastewater treatment operating conditions occurring on the day of sampling in the space provided on the fo Analysis 4 - Analyze the effluent for pollutants listed on the APAM form, including those to be identified and approximately quantified under the significant peaks rule, using appropriate EPA -approved methods for each of the analytic fractions. Other analytical methods can be substiti. only with prior, written approval of the Director of the Division of Environmental Management (DEM). Read and distribute to the laboral performing the analysis the accompanying memo (Tedder, October 1990) clarifying analytical requirements. 5 - Identify chemicals to be analyzed for according to the 10 significant peaks rule(as described in item 2 of the Annual Pollutant Anat Monitoring Requirement in the permit) using a GC/MS library search. Tentative identification is all that is required; confirmation by stem injection is not necessary. Estimate the concentration of each based on an internal standard having the closest retention time. Reporting 6 - Quantitation Limit Targets that should be met are listed on this Revised APAM Reporting Form A. Report the use of any higher quantita limit and an explanation as to why the listed quantitation limit target could not be met. Examples of acceptable reasons for not meetir quantitation limit target could be high background concentrations in a sample, or the necessity for sample fraction dilution to bring a chen to within a quantifiable concentration. List any quantitation limit differtent (whether higher or lower) from the target in the column provides this purpose. 7 - If a chemical is found to be below the quantitation limit, report the concentration as less than (or ' <' ) the quantitation limit in the appropriate space. Provide a concentration estimate for chemicals detected in concentrations greater than the detection limit and less the quantitation limit. Enter the detection limit in parentheses beside the estimate. Chemicals detected in concentrations above the quantit. limits must be quantified. Quantitation limit and detection limit are defined in the accompanying memo (Tedder, October 1990). Enter the number of peaks detected in each analytic fraction in the appropriate space on this Revised APAM Form A. Report all concentrations in umF micrograms per liter (pill and metals as total recoverable metal. 8 - If "significant peaks" are found, provide probable molecular weight, library match probability, retention time, identification basis, and MS number for each. In addition, list Internal standards and their retention times. 9 - In the'section labeled "Organic Analytical Information"(p•9), Include for each organic fraction the method, extration technique, GC oper conditions, and surrogate recovery. Report the size of the GS/MS library being utilized in the appropriate space. 10 - Use copies of this Annual Pollutant Analysis Monitoring Revised Form A to report the results of the analysis. Both the analytical labor representative and the facility operator in responsible charge should sign completed forms (last page). 11 - Mail two completed copies of the form (and the laboratory report, if submitted to the facility on a different form) to: ATTN: Central Division of Environmental Management, NC DEHNR, P.O. Box 29535, Raleigh, NC 27626. Mail the APAM form seperately from Disc'. Monitoring Reports. A. Purgeable (Volatile oraanlel Number of chemicals Fraction STORET Fraction. EPA Method 624 Page 2 of 9 detected in Fraction 0 Number 84086 STORET Compound Number Quantitation Limit Target Quantitation Limit* Concentration Detected GC/MS Confirmation ? 1. Pollutants to be analyzed for: (pg11) (/1) (Wgli1 Yes No 34210 Acrolein 100 100 <100 _ X 34215 Acrytonitrife 100 100 <100 X 34030 Benzene 5 5 <5 X 32101 Bromodichloromethane 5 5 <5 X 32104 Bromoform 5 5 <5 X 34413 Bromomethane 10 10 <10 X 32102 Carbon tetrachloride 5 5 <5 X 34301 Chlorobenzene 6 5 <5 X 34311 Chloroethane 10 10 <10 X 34576 2-Chloroethyi vinyl ether 10 10 <10 X 32106 Chloroform 5 5 7.9 X 34418 Chloromethane 10 10 <10 X 32105 Dibromochloromethane 5 5 <5 X 34496 1,1-Dichioroethane 5 5 <5 X 34531 1,2-Dichioroethane 5 5 <5 X 34501 1,1-Dichloroethytene 5 5 < 5 X 34546 trans-1,2-Dichioroethylene 5 5 <5 X 34541 1,2-Dichloropropane 6 5 <5 X 34704 cis 1,3-Dichloropropene 5 5 < 5 X 34699 trans 1,3-Dichloropropene 5 5 < 5 X 34371 Ethylbenzene 8 5 < 5 X 34423 Methylene chloride 5 5 < 5 X 34516 1,1,2.2-Tetrachloroethane 7 5 < 5 X 34475 Tetrachloroethylene 5 5 < 5 X 34010 Toluene 6 5 < 5 X 34506 1,1,1-Trichloroethane 5 5 < 5 X 34511 1,1,2-Trichloroethane 5 5 <5 X 39180 Trichloroethylene 5 5 <5 X 34488 Trichlorofluromethane 10 10 < 10 X 391175 Vinyl chloride 10 10 < 10 X • If different from quantitation limit target t 2. Other purgeables (up to 10 highest peaks) No Other Peeks identified Page 3 of 9 eith Compound Probable Molecular Weft Estimated Concentration Wes) Library Match Probabklty IS) Identification Basis (Chalk an that apply) Scan Number Retention Time CRT) (Min) Library Match Manual interpretation RT Complete only it non -targeted compounds are present: Internal Standard Retention Time (Min) E. Acid Extractable Fraction. Number of chemicals Fraction STORET EPA Method 625 Page 4 of 9 detected in Fraction 0 Number 45582 STORET Compound Number Quantitation Umit Target Quantitation Umit. Concentration Detected GC/MS Confirmation ? 1. Pollutants to be analyzed for: WW1) (pglll (11g/1 Yes No 34452 4-Chloro-3-methylphenol 10 _ 10 <10 X 34586 2-Chlorophenol 10 10 <10 X 34601 2,4-Dichlorophenol 10 _ 10 < 10 X 34606 2,4-Dimethylphenol 10 10 < 10 X 34616 2,4-Dinitrophenol 50 50 < 50 X 34657 2-Methyl-4,6-dinitrophenol 50 50 < 50 X 34591 2-Nitrophenol 10 10 <10 X 34646 4-Nitrophenol 50 50 < 50 X 39032 Pentachtorophenol 50 50 < 50 X 34694 Phenol 10 10 < 10 X 34621 2,4,6-Trichlorophenol 10 10 < 10 X " If different from quantitation limit target 2. Other add extrectsbiss (up to 10 highest peaks) No Other Peaks Identified Page 5 of 9 Compound Probable Molecular Weight Esdmated Concentration BMA Library Match Probability (%) (dendficatlon Basis (Check all that apply) San timber Retention Time (RT) (Min) I Library Match Manual Interpretation RT Coreptete only if non -targeted compounds are present: Internal Standard Retention Time (Min) C. Base/Neutral Fraction, Number of chemicals Fraction STORET EPA Method 625 0 Page 6 of 9 detected in Fraction Number 45683 STORET Compound Number Quantitation Limit Target Quantitatlon Limit• Concentration Detected GC/MS Confirmation ? 1. Pollutants to be analyzed for: • (Irg/l) (u9n) (p9n1 Yes No 3405 Acenaphthene 10 10 <10 X -_ 34200 Acenaphtylene 10 10 <10 X 34220 Anthracene 10 10 <10 X 39120 Benzidins 80 50 <SO X 34526 Benzo (a) anthracene 10 10 <10 X 34247 Benzo (a) pyrene 10 r 10 <10 X 34230 Benzo (b) ftuoranthene 10 10 <10 X 34521 Benzo Ight) perytene 10 10 <10 X 34242 Benzo () fluorenthene 10 10 <10 X 34278 Bis(2-chloroethoxy) methane 10 10 <10 X 34273 Btst2-chtcroethy0 ether 10 10 <10 X 34283 Bis(2-chtoroisopropy0 ether 10 10 <10 X 39100 Bis(2-ethythexy() phthalate 10 10 <10 X 34636 4-Bromophenyl phenyl ether 10 10 <10 X 34292 Butyl benzyl phthalate 10 10 <10 X 34581 2-Chtoronaphthalene 10 10 <10 X 34641 4-Chtcrophenyl phenyl ether 10 10 <10 X 34320 Chrysene 10 10 <10 X 34556 Oibenzo (a.h) anthrecene 10 10 <10 X 34536 1,2-Dichlorobenzene 10 10 <10 X 34566 1,3-Dichlorobenzens 10 10 <10 X 34571 1,4-Dichtorobenzene 10 10 <10 - X 34631 3,3-Dichtorobenrldine 20 20 <20 X 34336 Diethyl phthalate 10 10 <10 X 34341 DImethyl phthalate 10 10 <10 X 39110 Di•n-butyl phthalate 10 10 <10 X ^� 34611 2.4-Dinitrotoluene 10 10 < 10 X 34628 2.6-Oinitrototuene 10 10 <10 X 34596 Di-n-octyl phthalate 10 10 <10 X 34346 1,2-0iphenylhydrazlns 10 10 <10 X 34378 Fluoranthene 10 10 <10 X 34381 Fluarene 10 10 <10 X 39700 Hexachlorobenzene 10 10 < 10 X 34391 Hexachiorobutadlene 10 10 <10 X 34386 Hexachtorocyctopentadlene 10 10 < 10 X 34396 Hexachtoroethane 10 10 < 10 X 34403 Inderto(1.2,3-cd) !Wrens 10 10 <10 X 34408 Isophorone 10 10 <10 X 34698 Naphthalene 10 10 < 10 X �. 34447 Nitrobenzene 10 10 <10 X 34438 N-nitrosadimathylamine 10 10 4 < 10 X 30426 N-nitroso-di.n-propylamine 10 10 <10 X 34433 N-nitrosodiphenylamine 10 10 <10 X ..r 34461 V Phenanthrene 10 10 < 10 X 34469 Pyrene • 10 10 <10 X 34551 1,2.4-Trichtorobenzene 10 10 <10 X • If different from auantitatlon omit target d vk 2. Other base neutrals (up to 10 highest peeks) No Other Peaks Identified Pape 7 of 9 Compound Probable Molecular Weight Estimated Concentration I library Match Probability (Si Retention 71me (RT1 Mn) Identification Bads (Check al that apply) Library Match Manual tntsrpretstlan RT Scan Number Complete only If non -targeted compounds are present: Internal Standard Retention Time (Min) 0. Croanxhtorindorganophosphorw Pesticides and PCB's Page 8 of 9 Number of chemicals detected in Fraction Fraction STORET Number 00188 STORET Compound Quantitation Number Umit Target Quantitation Limit' Concentration Detected Dual Column Confirmation ? GC/MS Confirmation ? 1. Pollutants to be analyzed for: (mg/1) Organochlorine Pesticides!PCB's: EPA Method 8080 WA (Erg/1) Yes No Yes No 39330 Aldrin 0.05 0.05 <0.05 X X 39337 alpha-BHC 0.05 0.05 <0.05 X X 39338 Beta-BHC 0.05 0.05 <0.05 X X 34259 Delta-BHC 0.1 0.05 <0.05 X X 39340 Gamma-BHC (Undane) 0.05 0.05 <0.05 X X 39350 Chlordane 0.2 0.20 <0.20 X X _ 39310 4,4'-DOD 0.1 0.05 <0.05 r X __ 39320 4,4'-DOE 0.1 0.05 <0.05 X X 39300 4,4'-DDT 0.1 0.05 <0.05 X . `X 39380 , Dieldrin 0.02 0.05 <0.05 X X 34361 Endosulfan I (alpha) 0.1 0.05 <0.05 X X 34356 Endosulfan II (beta) 0.1 0.05 <0.05 X , X 34351 Endosulfan sulfate 0.7 0.05 <0.05 X X 39390 Endrin 0.06 0.05 <0.05 X X 34366 Endrin aldehyde 0.2 0.05 <0.05 X X 39410 Heptachlor 0.05 0.05 <0.05 X X 39420 Heptachlor epoxide 0.8 0.05 <0.05 X X 39480 ` Methoxychlor 0.5 0.05 <0.05 X X 39755 Mirex 0.2 0.05 <0.05 X X 39400 Toxaphene 2.4 2.0 <2.0 _ X X 34671 PCB 1016 0.5 0.50 <0.50 X X 39488 PCB 1221 0.5 0.50 <0.50 X X 39492 PCB 1232 . 0.5 0.50 <0.50 X X 39496 PCB 1242 0.5 0.50 <0.50 X X 39500 PCB 1248 0.5 0.50 <0.50 X X 39504 PCB 1254 1.0 0.50 <0.50 X x 39508 PCB 1260 1.0 0.50 <0.50 X X Organophosphours Pesticides: EPA Method 8140 39560 Demeton 2.5 2.0 <2.0 X x 39540 Parathion (ethyl) 0.6 0.5 <0.50 X E. Herbicides, Number of Fraction STORET EPA Method 8150 0 chemicals detected in Fraction Number 00148 STORET Compound Number Quantitation Umit Target Quantitation Limit' Concentration Detected Confirmation? Dual Column 1. Pollutants to be analyzed for: Wgll) WI) (ug/l) Yes No 39730 2,4-0 12 0.50 <0.50 X 39045 Silvex 2 0.20 <0.20 X 39740 2,4,5-T 2 0.20 <0.20 ' If different from quantitation limit Organic Analyt deal information: Page 9of9 Organic Fraction Method Extraction GC Operating Conditions Cottann Descdptiotts Surrogates (Sptkss) Batch Continuous Length Column Rate, X ID. Film Thickness. Type. Cartier Gas & Flow Temperature Program Compound Recover it Pwgeable 624 X 60m, 0.75 =11D, 1.5 ltm, VOCOL, 30•C (10 min) 1.2-Dichloro- ethane d-4 97.1 94•C. 6•/min 200•C. 4•/lain (10 rain) Toluene de 99.9 4-Bromo- Pluorobenzene 101 Acid Extractable 625 X 30N X 0.32 ma, 0.25 µm 2-Pluorophenol 33.4 DB-5, Be 30 cm/sec. 40•C Phenol d6 22.3 (4 min) 270•C. 10•/min 2,4.6-Tribromo- phenol 52.2 Base/Neutral Extractable 825 X See Above Nitrobenzene d5 58.5 _ 2-Pluoro-biphenyl 63.9 4-Test-phenyl d14 70.9 Example: Acid Extractable 625 X 30m x 0.25am, 0.2Sum. D8-S. Be. 30 cm/sec, 40•C (4 min) - 270•C. 10•min d5 - phenol 50 GC/MS Library size (number of reference spectra): 6 F. Metals and Other Chemicals Number of Metals and Other Chemicals las Listed below) detected in Fraction STOREY Number 78240 Sample 10 STORET Compound Number Quantitation Limit Target Quantitadon Limit • Concentration Detected 1. Pollutants to be analyzed for: (pg1 MA WO 01104 Aluminum 50 50 380 01097 Antimony 50 50 <50 01002 Arsenic 10 10 25 01012 Beryllium 25 25 <25 01027 Cadmium 2 2 3.0 01034 Chromium 5 5 13 01042 Copper 2 2 13 01051 Lead 10 10 1 <10 71900 Mercury 0.2 0.2 <0.2 10167 Nickel 10 10 11 01147 Selenium 5 5 5.0 01077 Silver 5 5 < 5 01092 Zinc 10 10 864 2. 0ther Inorganics 01007 Barium 500 500 <500 00940 Chloride 1000 1000 _ 9.500.000 00720 Cyanide 20 20 < 20 00951 Fluoride 100 100 2.090 • If different from quantitatlon limit target Anaiytic I La atory Represents e Si ned: 3 ft 3 l %%2 7 I Q 0 g Data: Facility Operator in Responsible Charge CORC): I certify that this report is accurate and complete to the beat of my knowledge: YM u,.r,.l.w..l.pmyl ,..1 RESEARCH & ANALYTICAL LAboRAToRIES, INC. Analytical / Process Consultations Phone (336) 996-2841 1(� e(11:41S ET ADDRIli ESS CS,TEZ Ill G aor? CONTA n PHONE rtkaiIan% 67.0V1 / la[ `TEMP) RES 'C CI SAMPLE NUMBER (IA8 USE ONLY) DATE TIME COMP GRAB JOB NO. PROJECT PLER NAME (11.6q►S PFj1NTI SAMPLER SIGNATURE CHLOMME SIMPLE REMOVED MA X (Yoie) Paw) SAMPLE LOCATION 1 LD. NO. OF CONTAINERS RELINQUISHED BY DATE/TIME RECEI D BY REMARKS: �,., C'NVA,w.oW DATE/TIME RECEIVED BY 5/A10* CHAIN OF CUSTODY RECORD i 31� i i REQUESTED ANALYSIS SAMPLE TEMPERATURE AT RECEIPT °C r f SLUDGE MANAGEMENT Sludge generated by the pollution abatement system is thickened in a thickening tank. After a period of thickening, the sludge is stored in a holding tank prior to being pumped to drums. The drums are transported by a regulated transport to Michigan Disposal where the sludge is then thickened. Once the sludge is thickened it is disposed of in a regulated landfill operated by Waste Management, Inc.