Loading...
HomeMy WebLinkAboutNC0086169_Permit (Modification)_20020812 (2)NPDES DOCUHENT :MCANNIN`i COVER SHEET NC0086169 Corning / Midland facility NPDES Permit: Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Correspondence Speculative Limits Instream Assessment (67b) Environmental Assessment (EA) Permit History Document Date: August 12, 2002 This document is prizited on reuse paper - ignore any content on the reYerse side State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross, Jr., Secretary Alan W. Klimek, Director Ms. Christy L. Hannan Corning Incorporated P.O. Box 1700 Concord, North Carolina Dear Ms. Hannon: 28026-1700 Al 7A NCDENR August 12, 2002 Subject: Modification of NPDES Permit NC0086169 Midland Plant Cabarrus County Division personnel have reviewed and approved your request for modification of the subject permit. Accordingly, we are forwarding this revised NPDES permit. This permit modification is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated May 9, 1994 (or as subsequently amended). The monitoring frequency for zinc, cadmium, and copper has been reduced to quarterly as a result of a reasonable potential analysis. This analysis indicates that effluent from your facility shows no reasonable potential to violated North Carolina's water quality criteria. If any parts, measurement frequencies or sampling requirements contained in this permit modification are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. Please note that this permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, the Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Nfichael Myers at telephone number (919) 733-5083, extension 508. Sincerely, an W. Klimek, P.E. cc: Mooresville Regional Office/Water Quality Section Point Source Compliance Enforcement Unit Technical Assistance & Certification Unit Aquatic Toxicology Unit Central Files NPDES Files 1617 MAIL SERVICE CENTER, RALEIGH, NORTH CAROLINA 27699-1617 - TELEPHONE 919-733-5083/FAX 919-733-0719 AN EQUAL OPPORTUNITY AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/ 1 0% POST -CONSUMER PAPER VISIT US ON THE INTERNET @ http://h20.enr.state.rlc.Us/NPDES Permit NC0086169 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Corning Incorporated is hereby authorized to discharge wastewater and stormwater from a facility located at Corning Incorporated U.S. Highway 601 Midland Cabarrus County to receiving waters designated as an unnamed tributary of Muddy Creek (outfall 001), an unnamed tributary of Clear Creek (outfall 002) and the Rocky River (outfall 003) in the Yadkin -Pee Dee River Basin in accordance with effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V and VI hereof. The permit shall become effective September 1, 2002. This permit and the authorization to discharge shall expire at midnight on October 31, 2003. Signed this day August 13, 2002. 4 t ,,,_..) f%A1an W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit NC0086169 SUPPLEMENT TO PERMIT COVER SHEET Corning Incorporated is hereby authorized to: 1. Continue to operate a 0.0274 MGD wastewater treatment facility (outfall 003) consisting of an equalization tank, an off -spec tank, a Lamella clarifier, two neutralization tanks and a neutralization transfer tank located at a facility located off of Highway 601 in Midland, Cabarrus County; 2. After receiving Authorization to Construct from the Division of Water Quality, construct and operate facilities for the discharge of up to 0.107 MGD through outfall 003; and 3. Discharge stormwater and boiler blowdown from a wet detention pond into an unnamed tributary of Clear Creek (outfall 002), discharge stormwater from a wet retention pond into an unnamed tributary of Muddy Creek (Outfall 001 - See Part II, Section A for monitoring requirements), and discharge process wastewater, cooling tower blowdown, and carbon filter backwash from the above referenced treatment works at the location specified on the attached map into the Rocky River (Outfall 003). All receiving streams are classified C waters in the Yadkin -Pee Dee River basin. Permit NC0086169 A. (2.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS — DRAFT During the period beginning on the effective date of this permit and lasting until expansion beyond 0.107 MGD, the Permittee is authorized to discharge from outfall serial number 003 - Industrial Process Wastewater, Non - contact Cooling Water, and Carbon Filter Backwash. Such discharges shall be limited and monitored by the Permittee as specified below: Effluent Characteristics �ts Monitoring Reauirements Monthly Average Daily Average Measurement Frequency Sample Type Sample Location' Flow 0.107 MGD Continuous Estimate Effluents Total Residual Chlorine 28 µg/L 2/Week Grab • Effluent Chloride 2/Week Composite Effluent Total Suspended Solids 30.0 mg/L 45.0 mg/L Weekly Composite Effluent Temperature (2C)2 Weekly Grab Effluent pH3 Weekly Grab Effluent Cadmium Quarterly Grab Effluent Copper Quarterly Grab Effluent Zinc Quarterly Grab Effluent Total Phosphorus Quarterly Composite Effluent Chronic Toxicity's Quarterly Composite Effluent Pollutant Anaiysis5 5 5 Effluent Notes: 1. The compliance point for flow shall be upstream of the non -contact cooling water and boiler blowdown internal outfall. The compliance point for all other parameters shall be at the Rocky River discharge location. 2. The temperature of the effluent will be regulated so that the temperature of the receiving stream does not increase more than 2.80C above natural water temperature. Receiving water temperature will not exceed a maximum of 320C. 3. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. 4. Chronic Toxicity (Ceriodaphnia) at 1.0%; January, April, July and October (see A. (4.)). 5. See A. (6.) Pollutant Analysis Condition. See Special Condition A. (9.) Annual Shutdown Procedures Condition There shall be no discharge of floating solids or visible foam in other than trace amounts. Definitions: MGD - Million gallons per day µg/L - Micrograms per liter mg/L - Milligrams per liter Permit NC0086169 A. (3.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS — DRAFT During the period beginning upon expansion beyond 0.107-MGD and lasting until expiration, the Permittee is authorized to discharge from outfall serial number 003 - Industrial Process Wastewater, Non -contact Cooling Water, and Carbon Filter Backwash. Such discharges shall be limited and monitored by the Permittee as specified below: Flow Monthly Average 0.142 MGD aiiy Average Meassurement Frequency Continuous Sample Type Estimate Sample Locations Effiuent1 Total Residual Chlorine Chloride 28 µg/L 2/Week 2/Week Grab Composite Effluent Effluent Total Suspended Solids Temperature (2C)2 pH3 30.0 mg/L 45.0 mg/L Weekly Weekly Weekly Composite Grab Grab Effluent Effluent Effluent Cadmium Quarterly Grab Effluent Copper Zinc Quarterly Quarterly Grab Grab Effluent Effluent Total Phosphorus Chronic Toxicity4 Quarterly Composite Effluent Quarterly Composite Effluent Pollutant Analysis5 5 5 Effluent Notes: 6. The compliance point for flow shall be upstream of the non -contact cooling water and boiler blowdown internal outfall. The compliance point for all other parameters shall be at the Rocky River discharge location. 7. The temperature of the effluent will be regulatedso that the temperature of the receiving stream does not increase more than 2.80C above natural water temperature. Receiving water temperature will not exceed a maximum of 320C. 8. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. 9. Chronic Toxicity (Ceriodaphnia) at 1.0%; January, April, July and October (see A. (4.)). 10. See A. (6.) Pollutant Analysis Condition. See Special Condition A. (9.) Annual Shutdown Procedures Condition There shall be no discharge of floating solids or visible foam in other than trace amounts. Definitions: MGD - Million gallons per day µg/L - Micrograms per liter mg/L - Milligrams per liter Facility Name = Qw (MGD) = WWTP Classification NPDES # = Receiving Stream IWC (%) = Corning Inc. 0.107 2; NC0026573' 1.00 easonable Potential Sunman Final Results: Stream Classification 7Q10s (cfs)= 30Q2 (cfs) Qavg (cfs) 10 2° 3° 4° C Cadmium Max. Pred Cw Allowable Cw 1/2 FAV (non Trout) 1/2 FAV (Trout) 1/2 FAV 1.0 pg/1 200.0 g/1 15.0 pg/1 2.1 µg/1. 42 µ8/1 Implementation !Are all reported values less than? Its the detection limit acceptable? Yes Yes Limit? No !Monitoring Monitor? No 'Frequency None Copper Max. Pred Cw Allowable Cw 1/2 FAV 1/2 FAV 308.4 pg/1 700.0 pg/1 7.3 NFL 5.8 pg/1 I Implementation Are all reported values less than? 'Is the detection limit acceptable? No Limit? No Yes Monitor? Yes Monitoring 'Frequency Monthly Zinc Max. Pred Cw Allowable Cw 1/2 FAV 1/2 FAV 2053.9 µg/1 5000.0 g/1 67.0 N� 95.0 pg/l Implementation :Are all reported values less than? :Is the detection limit acceptable? No Yes Limit? No Monitor? Yes Monitoring !Frequency Monthly Facility Name = Qw (MGD) = WWTP Classification NPDES # = Receiving Stream 1WC (%) = Corning Inc. 0.107 NC0026573 1.00 easonable Potential Summar' Final Results: Stream Classification 7Q1Os (cfs)= 30Q2 (cfs) Qavg (cfs) 10 2° 30 4° C' 30 Cadmium Max. Pred Cw Allowable Cw 1/2 FAV (non Trout) 1/2 FAV (Trout) 1/2 FAV 1.0 pg/1 117.6 g/1 15.0 it 2.1 pg/1 42 ug/1 Implementation !Are all reported values less than? Is the detection limit acceptable? Yes Yes Limit? No Monitor? No !Monitoring 'Frequency None Copper Max. Pred Cw Allowable Cw I Implementation 308.4 pg/1 i Are all reported values less than? 411.8 g/1 s Is the detection limit acceptable? 7.3 µg/1 5.8 pg/1 No Yes Limit? No Monitor? Yes Monitoring 'Frequency Monthly Zinc Max. Pred Cw Allowable Cw 1/2 FAV 1/2 FAV 2053.9 pg/1 2941.2 g/1 67.0 Ng/1 95.0 pg/1 1 Implementation :Are all reported values less than? :Is the detection limit acceptable? No Yes Limit? No 'Monitoring Monitor? Yes , Frequency Monthly CORNING Discovering Beyond Imagination Corning Incorporated Optical Fiber July 11, 2002 PO Box i7oo Concord, NC 28026-170o CERTIFIED MAIL RETURN RECEIPT REQUESTED t 704 569 6000 www.corning.com r JUL 1 8 2002 DENR-WATER QUALITY POINT SOURCE RF?ANCH Mr. Dave Goodrich North Carolina Department of Environment and Natural Resources Division of Water Quality, NPDES Permit Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: Corning Incorporated, Concord Facility NPDES Permit No. NCG010000- Sampling Parameter Evaluation Dear Mr. Goodrich: NccCSltI`1 As required by our NPDES permit, effective December 1, 2001, we have analyzed samples from Outfall 003 for cadmium, copper and zinc. Our permit states that after seven sampling events the permittee may request (in writing) that the Division evaluate this parameter and modify the permit accordingly. Attached are the analysis results of the subject sampling events. We are requesting that DWQ evaluate the results an modify our current NPDES permit if subjecj r i ping is no longer necessary. Please feel free to contact me if you have any questions concerning the information presented. I can be reached at (704) 569-6268. Sincerely, Christy Hannan Environmental Control Engineer Concord Plant Corning, Inc. Enclosures Cc: Mooresville Regional Office, NCDENR EFFLUENT CORNING INCORPORATED Metals Summary for Outfall 003 December 2001 thru June 2002 NPDES PERMIT NC 0086169 Class II P/C Cabarrus County Linked to DMR for the Month of DATE 01027 01042 01092 CADMIUM COPPER 0 z uG/L uG/L uG/L DECEMBER 2001 19 <0.5 <20 916 JANUARY 2002 16 <0.5 109 965 FEBRUARY 2002 5 <0.5 73 675 MARCH 2002 5 <0.5 41 384 APRIL 2002 2 <0.5 76 426 MAY 2002 7 0.5 71 570 J U N E 2002 5 <0.5 82 645 Metals Review for 7 months 7/8/02 4:16 PM