HomeMy WebLinkAboutSW6220501_Design Calculations (Riprap)_20220621ATE DESIGN PHASE 2-11-22 PRELIM rPROJECT NAME PROJECT NO CONSTR / Xview Park 1722 REVISIONTION RECORD BY Ho e Mills, North Carolina UP O THEIR (SPECIFY) CHECKED BY CSB Storm Outlet Structure FES No.= #REF! Pipe Dia= #REF! in Q10 = #REF! cfs Qfull = #REF! cfs Vfull = #REF! fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: s Length Storm Outlet Structure FES No.= PO 12 Pipe Dia= 24 in Q10 = 11.77 cfs Qfull = 59.49 cfs Vfull = 18.91 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: Zone D50 DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End Zone D50 DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End Q1o/Qfull = #REF! V/VfuII = #REF! V = #REF! fps P� = 8 in = 12 in = B = 18 in = #REF! ft = #REF! ft = #REF! ft Q10/Qful1 = 0.20 V/Vfull = 0.78 V = 14.8 fps = 2 = 8 in = 12 in = B = 18 in = 12.0 ft = 6 ft = 14.0 ft 1722 Storm System.xlsx LATEST REVISION: 6/21/2022 7:48 AM PAGE 1 OF 3 ATE DESIGN PHASE PRELIM 2-11-22 rPROJECT NAME PROJECT NO CONSTR / Xview Park 1722 REVISIONTION RECORD BY ,Hope Mills, North Carolina UP OTHER (SPECIFY) CHECKED BY CSB Storm Outlet Structure FES No.= PO 2 Pipe Dia= 15 in Q10 = 2.42 cfs Qfull = 13.86 cfs Vfull = 11.28 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: Storm Outlet Structure FES No.= PO 19 Pipe Dia= 24 in Q10 = 13.55 cfs Qfull = 21.47 cfs Vfull = 6.83 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: s Length Zone D5o DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End Zone D5o DMAX Riprap Class Apron Thickness Apron Length Apron Width @ Outlet Apron Width @ End Q1 o/Qfu I = 0.17 V/Vfu 11 = 0.72 V = 8.1 fps = 2 = 8 in = 12 in = B = 18 in = 7.5 ft = 3.75 ft = 8.8 ft Q10/Qfu11 = 0.63 V/Vfu11 = 1.06 V = 7.2 fps = 2 = 8 in = 12 in = B = 18 in = 12.0 ft = 6 ft = 14.0 ft 1722 Storm System.xlsx LATEST REVISION: 6/21/2022 7:48 AM PAGE 2 OF 3 PROJECT NAME Southview Park LOCATION Hope Mills, North Carolina Storm Outlet Structure FES No.= Skimmer Pipe Dia= 2 in Q10 = 0.02 cfs Qfull = 0.02 cfs Vfull = 153.00 fps From Fig. 8.06.b.1: Zone From Fig. 8.06.b.2: s v 3 Length DATE DESIGN PHASE PRELIM 02-11-22 PROJECT NO CONSTR 1722 REVISION RECORD BY UP OTHER (SPECIFY) CHECKED BY CSB Q10/Qful1 = 1.00 V/Vfu I = 1.14 V = 174.4 fps D50 = 4 in DMAX = 6 in Riprap Class = A Apron Thickness = 9 in Apron Length = 0.7 ft Apron Width @ Outlet = 0.5 ft Apron Width @ End = 0.8 ft 1722 Storm System.xlsx LATEST REVISION: 6/21/2022 7:48 AM PAGE 3 OF 3