Loading...
HomeMy WebLinkAbout490038_Compliance Evaluation Inspection_20200302Facilitf Number ('Division of Water Resources 0 Division of Soil and Water Conservation 0 Other Agency Type of Visit: &Com Hance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: Farm Name: ?Arrival Time: Departure Time: Owner Name: P.VN R. atrAb✓lt Mailing Address: Physical Address: Facility Contact: nb Owner Email: Phone: County: Region: Onsite Representative: Certified Operator: Back-up Operator: Location of Farm: Title: Latitude: Integrator: Phone: Certification Number: Certification Number: Longitude: Swine Design Current Capacity Pop. Wean to Finish Wean to Feeder Feeder to Finish Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Other Other Design Current Wet Poultry Capacity Pop. Layer Non -Layer Design Current Dry Poultry Capacity Pop. Layers Non -Layers Pullets Turkeys Turkey Poults Other Cattle Design Current Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow Non -Dairy Beef Stocker Beef Feeder Beef Brood Cow Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure El Application Field El Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? ❑ Yes ❑ NA ❑NJ ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE d. Does the discharge bypass the waste management system? (If yes, notify DWRJ 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverseimpacts or potential adverse impacts to the waters of the State other than from a discharge? ❑ Yes ❑No ❑NA ❑NE ❑ Yes .No ❑NA ❑NE ❑ Yes c4 No ❑ NA ❑ NE Page 1 of 3 2/4/2014 Continued Facility Number: ' - 3 S Waste Cdllection & Treatment Date of Inspection: ;3 - ,2 -0 2, 0 4. is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? ❑ Yes o ❑ NA ❑ NE a. If yes, is waste level into the structural freeboard? ❑ Yes ❑ No ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Spillway?: Designed Freeboard (in): Observed Freeboard (in): .20 5. Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a ❑ Yes waste management or closure plan? If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? ❑ Yes JNo ❑ NA ❑ Yes ekNo ❑ NA 8. Do any of the structures lack adequate markers as required by the permit? (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes ❑ No a NA ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. IDTotal Phosphorus ElFailure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area ►.!1 Pi No El NA ❑NE No ❑NA El NE 12. Crop Type(s): 13. Soil Type(s): ❑ Yes 2No ElNA ❑ NE ElNE IDNE El NA ❑NE 14. Do the receiving crops differ from those designated in the CAWMP? 15. Does the receiving crop and/or land application site need improvement? 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acres determination? 17. Does the facility lack adequate acreage for land application? 18. Is there a lack of properly operating waste application equipment? Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check the appropriate box. ❑ WUP ❑ Checklists ❑ Design ❑ Maps El Lease Agreements ❑ Other: ❑ Yes ❑ No Gj. A ❑ Yes ❑ No p_NA ❑ Yes ❑ No xfNA 1NE ❑ Yes ❑ No ❑ NA IlfNE ❑ Yes Ki No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA 0 NE ❑ Yes ❑ No ❑ NA W NE 21. Does record keeping need improvement? If yes, check the appropriate box below. Yes ❑ No ❑ Waste Application El Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis Waste Transfers El Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes ❑ No 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ❑ No Page 2 of 3 ❑ NA ❑NE ❑ Weather Code ❑ Sludge Survey ❑ NA ❑ NA NE NE 2/4/2014 Continued Facility Number: - 3g Date of Inspection: 3 -,2 - 2-o 2o 24. Did the 'facility fail to calibrate waste application equipment as required by the permit? 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: ❑ Yes ❑ No ❑ NA NE ❑ Yes ❑ No Alf NA -0 NE ❑ Failure to develop a POA for sludge levels 26. Did the facility fail to provide documentation of an actively certified operator in charge? 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: ❑ Yes AN° ❑ Yes ❑ No ❑ Yes ❑ Yes ❑ Yes ❑ Yes 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? ❑ Yes ❑ Yes ❑ Yes No ctr No pONo ❑ No El NA ❑NE 0 NA ❑ NE El NA ❑NE ❑NA El NE ❑NA ❑NE ❑ NA NE ► t" �To ❑NA ❑NE No ❑ NA ❑ NE No ❑ NA ❑ NE Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain situations (use additional pages as necessary). (Jetr,wA. -� o B Cowfs 6v1o� - I511) OArA.A9e of- dLA,11 elk 4Ai e,V 3 ss Uw�orl Ro,,; (4/14 P8 -r i►-ate G0wS s7 nc,c.J;Aly )--c)Ll FLP&) (J06w1 if) 5?,7, 2-D/g p ur1p ec,1 Fib 20 Zo l CA,LA Lk) l MCI? s .G3C0 'CA,GOr) co \-- 4 Up --e, L M P Reviewer/Inspector Name: (7i144.04 Mw Pr"- Phone: 7641-o235=243J Reviewer/Inspector Signature: Page 3 of 3 Date: 3 2/4/2014