Loading...
HomeMy WebLinkAbout230009_Compliance Evaluation Inspection_20210728Facility Number o3 C7 Division of Water Resources 0 Division of Soil andWater Conservation • 0 Other Agency Type of Visit: atom fiance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: (`3 Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: Farm Name: Owner Name: Arrival Time: C IoJer 3a) Departure Time: Mailing Address: Physical Address: Facility Contact: " CCr pi't'- ail ( 3.30 Owner Email: Phone: County: Region: Onsite Representative: Certified Operator: Back-up Operator: Location of Farm: Title: Phone: Latitude: Integrator: Certification Number: Certification Number: Longitude: AQC, 23--9 Swine a, Design Current 4'Capacity Pop. Wean to Finish Wean to Feeder Feeder to Finish Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Other Other Design Current Wet Poultry Capacity - ,Pop. Layer Non -Layer Design `Current Dry Poultry Capacity Pop. Layers Non -Layers Pullets • Turkeys • Turkey Poults Other Cattle Design Current Capacity = Pop. f' Dairy Cow 2 2 S f 1r8 Dairy Calf - Dairy Heifer Dry Cow , Non -Dairy Beef Stocker Beef Feeder Beef Brr,od Cow I Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the State other than from a discharge? ❑ Yes ❑NA ❑NE ❑Yes ❑No ❑NA ❑NE ❑ Yes ❑No ❑NA ❑NE ❑ Yes ❑ Yes ❑ Yes ❑No ❑NA ❑NE [7No ❑ NA ❑ NE ??No ❑ NA ❑ NE Page 1 of 3 2/4/2015 Continued Facility Number: 2 3 - Date of Inspection: %/2g/_ I Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? a. If yes, is waste level into the structural freeboard? Structure 1 Structure 2 Structure 3 Structure 4 Identifier: (O t,is/' Spillway?: Designed Freeboard (in): 2 5, Z- 20 , Observed Freeboard (in): 5. Are there any immediate threats to the integrity of any of the structures observed? (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? ❑ Yes No ❑ NA ❑ NE ❑ Yes ❑No D NA ❑NE Structure 5 Structure 6 ❑ Yes peo ❑ NA ❑ Yes 1,,No ❑ NA ❑ NE ❑ NE If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? 8. Do any of the structures lack adequate markers as required by the permit? (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Excessive Ponding ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Outside of Acceptable Crop Window 12. Crop Type(s): 13. Soil Type(s): ❑Yes No ❑NA ❑NE ❑ Yes No ❑ NA ❑ NE ❑ Yes pi No ❑ NA ❑ Yes 1:010 ❑ NA ❑ Yes ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ Total Phosphorus ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area N ❑ NA ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ NE ❑ NE ❑ NE 14. Do the receiving crops differ from those designated in the CAWMP? 15. Does the receiving crop and/or land application site need improvement? 16. Did the facility fail to secure and/or operate per the irrigation design or wettable acres determination? 17. Does the facility lack adequate acreage for land application? 18. Is there a lack of properly operating waste application equipment? Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check the appropriate box. ❑ WUP ❑ Checklists ❑ Design ❑ Maps ❑ Lease Agreements 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Yes ❑ Yes ❑ Yes No No No ❑ NA ❑ NA ❑ NA ❑ NE ❑ NE ❑ NE ❑ Yes PION ❑ NA ❑ NE ❑ Yes I7No ❑ NA ❑ NE ❑ Yes No ❑ NA ❑ NE ❑ Yes No ❑ NA . ❑ NE ❑ Other: ❑ Yes No ❑ NA ❑ NE ❑ Waste Transfers ❑ Weather Code ❑ Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes [No ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ❑ No ❑ NA L(NE Page 2 of 3 2/4/2015 Continued Facility Number: 2 3 - F 24. Did the facility fail to calibrate waste application equipment as required by the permit? 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the appropriate box(es) below. ['Failure to complete annual sludge survey ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: ❑ Yes o ❑ NA ❑ NE ❑ Yes ❑ No A ❑ NE ['Failure to develop a POA for sludge levels 26. Did the facility fail provide documentation of an actively certified operator in charge? 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: ❑ Yes ro o ❑NA ❑NE ❑ Yes ❑ No INA ❑ NE ❑ Yes �;� o ❑NA ❑NE ❑ Yes FNo ❑ NA ❑ NE ❑ Yes �;� o ❑ NA ❑ Yes ❑ No ❑ NA 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? ❑ Yes ❑ Yes ❑ Yes 4 No No O No 1111 ❑ NA ❑ NA ❑ NA ❑ NE 4NE ❑ NE Cl NE ❑ NE Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to;better explain situations (use additional pages as necessary). 3-101yZl 4.2� (i4z) oc.1,& 2 2 0, 2_,921 Reviewer/Inspector Name: 71/C/Lesii Reviewer/Inspector Signature: Page 3 of 3 Phone: T F — 7p % -0 / 7) Date: 7 z- / _O Z ( 2/4/2015