1 2 3 4 5 6
BOLT(S)ON MH FRAME. PROVIDE
BOLTDOWN COVER(S), ONLY
8" SEE NOTE 4 WHERE SPECIFIED CL
„ If
BrownAND
3/4 DIA "o)
SEEN TE 4 •
� O � BOLT(S) ON MH FRAME.
PLACE MASTIC
c° _ HOLES (TYP) VARIES BETWEEN GRADE RINGS VARIES PROVIDE BOLTDOWN COVER(S), Ca dwel
ti (0" MIN-12" MAX) (0" MIN-12" MAX) ONLY WHERE SPECIFIED
ENVIRONMENTAL ENGINEERING AND CONSULTING
M O O VARIES 309 East Morehead Street, Suite 160, Charlotte, NC 28202
N ALTERNATE GRADE RINGS (0" MIN- PLACE MASTIC VARIES (704)358-7204
2 1 /4" 8 1 /2" _ AS REQUIRED 12" MAX) BETWEEN GRADE (0" MIN- North Carolina Board of Examiners for Engineers and
o HOLES 12" MAX) Surveyors License No. F-0785
RINGS
PLAN � CONE SECTION
GRADE RINGS
D MH STEPS AS REQUIRED D
0 0 6x8 TIMBER POST 16" O.C. (TYP)
6p PRECAST CONCRETE CONE SECTION
RISER SECTION WITH FLAT SLAB UPPER SECTION
CO N HORSESHOE CUT-OUTS MH STEPS
Cy oI�1 FOR EXISTING SEWER PIPE ALLOWED ONLY WHERE DEPTHS WILL 15" O.C. (TYP) �����������.�
I NOT PERMIT CONE SECTIONS ���,•�� CiAR� ��#
W-BEAM WOOD POST W-BEAM BLOCK FOR M STEPS ?•�oFEss�o�q�q
MONOLITHIC CONCRETE BASE AND e •
1 " O.C. (TYP) COLLAR PLACED UNDER EXISTING FLAT SLAB UPPER SECTION : Q •
WOOD POST CAST -IN PLACE SEWER MAIN WITH EXCAVATE TRENCH
EXISTING �L
SPLICE BOLT SLOT (TYP) MANHOLE KEY WITH FORMED IN -PLACE STD, SEWER LINE ALLOWED ONLY
CO WWHERE
SE DEPTHS WILL 365 nr
MANHOLE KEY. NOT MH STEPS
29/32" x 1 1/8" FACE OF 4" 1 O.C. (TYP) �,�� ENGINE ;� •O�
ELEVATION GUARDRAIL 18" MIN �'" ••. n
.....
a 3/4"PIPE •,FiQ� Y v tG,��•
2�_0�� ° DIAME ,ER
END SECTION 1 3/4" POST BOLT ?8°' MIN .. f
RESHAPE -
MIN WASHER AND ° 12" MIN INVERT NOTES:
5/8"x18" BUTTON D 1. MANHOLE RISERS AND CONE SECTIONS
HEAD BOLT W/ ° s SHALL CONFORM TO ASTM C-478, LATEST
MONOLITHI CONCRETE o 0 0 0 <00 6" REVISION.
7/32" OVAL GRIP q '
i AND RECESSED 6" MIN DEPTH OF COMPACTED AND LEVELED 2. TRANSITION RINGS SHALL HAVE A MINIMUM
W-BEAM HEX NUT WASHED STONE EXTENDED AT LEAST 12" CLEARANCE OF 2'-0" ABOVE THE EFFLUENT
PAST CONCRETE ANTI -FLOTATION COLLAR TO 2NEW SEWER F �' MH STEPS OVERT ELEVATION.
GUARDRAIL UNDISTURBED EARTH OQ F•
LINE WITH
PER STD n1 FLEXIBLE
SPEC CONNECTOR PRECAST CONCRETE 3. MAXIMUM HEIGHT OF GRADE ADJUSTMENT
NOTES. NOTES: RISER SECTION RINGS SHALL NOT EXCEED 12".
STACKED ON CAST -IN
PROPOSED 1. TRANSITION RINGS SHALL HAVE A MINIMUM CLEARANCE OF 2'-0" PLACE KEY 4. NORTHING/FASTING LISTED ON PLANS
FACE OF FINISH GRADE ABOVE THE EFFLUENT INVERT ELEVATION. 3/4" PIPE FINAL DRAWINGS - FOR REVIEW
1. BEAM GUARDRAIL POST DIAMETER INDICATE THE CENTER OF THE MH RIM AND
C SPACING SHALL BE 6'-3" ON CURB OVER MONOLITHIC
EXISTINGO SEWER MAIN NCRETE PLACED - NOT THE CENTER OF THE MH STRUCTURE PURPOSES ONLY - NOT
2. FLEXIBLE WATERTIGHT SYNTHETIC RUBBER SLEEVES, WITH 4 C
c�1
CENTERS. FOR ECCENTRIC MHs. RELEASED FOR CONSTRUCTION
W STAINLESS STEEL CLAMP, DRAW BOLT AND NUT; OR CAST -IN SECTION A -A � O
LU SLEEVE; OR "A" LOCK CONNECTION SHALL BE FURNISHED FOR (NTS) d 5. SEE 33 05 13.16 FOR ADDITIONAL
2. BEAM GUARDRAIL POST a ao O EACH NEW PIPE TO CORED MANHOLE CONNECTION. SPECIFICATIONS.
SHALL BE EMBEDDED AT co w 3. MAXIMUM HEIGHT OF GRADE ADJUSTMENT RINGS SHALL NOT
LEAST 3'-8" BELOW FINISH w EXCEED 12". WSACC
GRADE. 4. NORTH ING/EASTING LISTED ON PLANS INDICATE THE CENTER OF
THE MH RIM AND NOT THE CENTER OF THE MH STRUCTURE FOR
a 4 ECCENTRIC MHs.,
a 5. INSIDE THE MANHOLE, FORM TROUGH WITH GROUT, FINISH
INVERTS AND WATER PROOF ALL COLD JOINTS AND AROUND ALL
PIPES.
MODIFIED CITY OF CONCORD STANDARD DETAIL MODIFIED WSACC STANDARD DETAIL S2.0
ROCKY RIVER
M GUARDRAIL N DOGHOUSE CONCRETE MANHOLE P STANDARD PRECAST CONCRETE MANHOLE REGIONAL
VARIES SCALE: NTS VARIES SCALE: NTS VARIES SCALE: NTS
WASTEWATER
DOUBLE CHECK VALVE ASSEMBLY �I PRECAST, POLYMER CONCRETE W (2' MIN) GENERAL NOTES:
TREATMENT PLANT
SHUT OFF VALVE # 1 ggHYT OFF VALLV�p # 6" 1. HYDRANTS SHALL BE MUELLER COMPANY - MODEL: SUPER CENTURION 250; AMERICAN FLOW CONTROL - MODEL 5Y4" PHASE 3 EXPANSION
RESILIENT SEA 8 GATE CHECK VALVE #2 VE IE WITHEAY[b#GEEL TRENCH WITH GRATE MIN B-84-B; MEDALLION; OR EQUAL WITH BLACK PRIMER FINISH.
VALVE WITH HANDWHEEL
OPERATOR. SEE NOTE 5. CHECK VALVE #1 71 OPERATOR. SEE NOTE 5.
__ `_ z 2. HYDRANT SHALL HAVE INTEGRAL SNAP -TIGHT STYLE STORZ CONNECTION WITH 5),4" VALVE OPENING, OPEN LEFT,
%" PENTAGON NUTS, TWO-2 Y2" NST CONNECTIONS, ONE-5" STORZ CONNECTION, DRAIN HOLES OPEN, AND 6" MJ SHOE. REVISIONS
7 / /3. MINIMUM BURY DEPTH OF S-6".
TEST COCK 4. ALL HYDRANTS SHALL STAND PLUMB. HYDRANTS WITH PUMPER NOZZLES SHALL HAVE HOSE NOZZLES PARALLEL WITH, AND REV DATE DESCRIPTION
RESTRAINED o o II FLOWy RED NOTED Q 4 THE PUMPER NOZZLE PERPENDICULAR TO, THE CURB LINE. ALL HYDRANTS SHALL BE ORIENTED SO THAT THE PUMPER
i? NOTE 4 T = NOZZLE FACES THE CURB OR AS DIRECTED BY THE CITY.
B 5. HYDRANT SHALL BE LOCATED AT LEAST 3' BEHIND THE CURB AND LESS THAN 10' FROM THE EDGE OF THE ROAD PAVEMENT B
� IIIIIII-III-I I I II- I I� III -III-' OR AS DIRECTED BY THE CITY.
SEE NOTE 2. _ 6. ALL OTHER MATERIALS AND INSTALLATION MUST CONFORM WITH THE TECHNICAL STANDARDS OF WSACC AND CITY OF
RIGID PIPE 12" MIN. CONCORD.
SEE NOTE 4.
30" MAX. SEE NOTE4. NOTE: TRENCH TO HAVE BUILT IN SLOPE OF 0.6% 1 ;I I F FIRE HYDRANT PAINT COLOR CODE REQUIREMENTS:
3H:1 V -III ALL NEW FIRE HYDRANTS SHALL BE PAINTED SAFETY RED, HYDRANT TEE
_ G�UNDI� PRECAST POLYMER SHERWIN WILLIAMS SW4081 LVR 11% OR EQUAL.
I-III-i i i i- i L--------- = i-i ..
CONCRETE TRENCH DRAIN
RIGID PIPE - - RIGID PIPE
SEE NOTE 4. P� N, 4-�NC�Sp p( P,�& AT MIN. SEE NOTE 4.
III R��UIR�D BEYTSYSTEM�SIGNER III
C-0�� 2 SCALE: NTS
Z
RESTRAINED RIGID PIPE TO 5' PAST
ffNOTE 4 BEND. SEE NOTE 4.
FILL PIPE WITH CONCRETE AND
DIAMETER
ELEVATION
DOME AT PIPE TOP, TYPICAL
N.T.S.
8" DIAMETER STANDARD
- - - - -
SHUT O F CHECK CHECK SHUT O,FF
VALVE 1 VALVE #1 VALVE #2 VALVE # 2
STEEL PIPE
DOME CONCRETE AT PIPE
Z
SWALE
HEIGHT (H) (FT)
WIDTH (W) (FT)
1
1.00
4.50
2
0.75
4.00
3
0.75
4.00
4
0.50
2.75
5
0.50
2.75
6
1.00
4.00
7
1.00
4.50
FOR ALL FIELD PAINTING, ALL SURFACES SHALL BE SANDBLASTED GATE VALVE
AND PROPERLY PREPARED ACCORDING TO THE PAINT
MANUFACTURER'S RECOMMENDATION PRIOR TO PAINTING. ALL FIRE
LINE IS 2 INCHES
AT FULL SIZE
HYDRANTS AND ANY PORTIONS OF THE HYDRANT ASSEMBLY o O o 0
EXPOSED TO VIEW (ABOVE ADJACENT GROUND ELEVATION) SHALL BE °
PAINTED WITH TWO (2) OR MORE EVENLY APPLIED COATS OF o Op O O
HYDRANT ENAMEL PAINT. HYDRANTS WILL BE RETOUCHED / 0
DESIGNED: D. WRIGHT
REPAINTED AS NECESSARY AFTER INSTALLATION AND PRIOR TO O O 00 °
ACCEPTANCE.
RESTRAIN WITH
DRAWN: R. JAMES
ROMAC GRIPRING
CHECKED: K. DEVENDORF
OR MEGA -LUG
RESTRAINT SYSTEM
CHECKED: D. VARJABEDIAN
APPROVED: K. DEVENDORF
SUPPORT, 4-INCH THICK PAD AT MIN.
AND CONCRETE FOOTINGS AS
REQUIRED BY SYSTEM DESIGNER__*_I ° R-� I "
STEEL PLATE FLANGE o Q FILENAME
3�8%1'-0" SQUARE 3 4 RIPRAP 154689-C-000-803.DWG
'TEST
ocK #1 -� 30.5" MIN' BC PRO U PROJECT NUMBER
L____________-_____-___-_-___-_-___-_____-J CONCRETE SLAB ON GRADE 156673
PLAN SOME LOCATIONS
�-III-III-III=I CLIENT PROJECT NUMBER
NOTES: N.T.S. _ 18" MIN. AS REQUIRED BY
0 0 0 0 MANUFACTURER OF
1. 6" - 10" RP SHALL BE SUPPORTED WITH ADEQUATE SUPPORT PEDESTAL(S). 10" DIAMETER STANDARD II II GEOTEXTILE FABRIC. - #57 STONE FIRE HYDRANT CIVIL
STEEL PIPE AT REMOVABLE II II MIRAFI 140N OR / / / / / GRAVEL TO
2. A HEATED ENCLOSURE SHALL BE INCLUDED FOR THE ABOVE GROUND BACKFLOW ASSEMBLEY. Z APPROVED EQUAL \�\������ 6' ABOVE
GUARD POST 1 II I I_ 11 WEEP HOLE
A 3. 2 2" TO 3" BRASS, K-COPPER OR GALVANIZED PIPE, 4" TO 10" DIP. RESTRAINED JOINTS SHALL BE WITH MEGA LUG 11 II I RIPRAP LINING FOR SWALE 4 O BURY-3' 6" MIN. A
RESTRAINTS OR APPROVED EQUAL. NOTES: I I I II UOO
STANDARD DETAILS
4. 21" - 10" DCVA INCLUDES SHUT OFF VALVES #1 AND #2 AS PART OF THE ASSEMBLY. NO SUBSTITUTIONS SHALL BE -II I II NOTES:2 1. BOLLARDS SHALL BE NOT LESSPERMITTED. a°. oa ; . • °
THAN T AWAY FROM THE -III L=J 1. REFERENCE THE GRADING AND DRAINAGE
5. TEST COCK #1 SHALL BE UPSTREAM OF SHUT OFF VALVE #1 AND IS PART OF THE APPROVED ASSEMBLY. PROTECTED OBJECT. Z DRAWINGS (300 SERIES) FOR SWALE LOCATIONS. 801b BAG OF
STONE PAD CONCRETE
MODIFIED CITY OF CONCORD STANDARD 2. BOLLARDS SHALL BE SPACED NOT - 2. THE MINIMUM SLOPE FOR ANY SWALE IS 1 %.
DETAIL MORE THAN 4' ON CENTER. MODIFIED CITY OF CONCORD STANDARD HYDRANT ASSEMBLY DETAIL
BACKFLOW PREVENTER (a:) BOLLARD TYPICAL SWALE SECTION � FIRE HYDRANT DRAWING NUMBER
C-000-202 SCALE: NTS VARIES SCALE: NTS VARIES SCALE: NTS VARIES SCALE: NTS
� C-000-803
1 2 3 4 5 6