HomeMy WebLinkAboutSW3220305_Plansheet - Notes_20220325 (4)1 2 3 4 5 6
CROSS REFERENCING SYSTEM CROSS REFERENCING SYSTEM (CONTINUED) GENERAL NOTES
Brown AND
1. PLAN TITLES: 6. TYPICAL DETAIL REFERENCE: 1. THE NOTE IN THE TITLEBLOCK OF THIS DRAWING WHICH READS "TWO INCHES AT FULL SCALE" APPEARS ON DRAWINGS FOR Caldwell
TYPICAL DETAIL NUMBER IDENTIFICATION OF SCALE DISTORTIONS ON HALF SIZE DRAWINGS AND DRAWING REPRODUCTIONS. IT SHALL MEAN THAT THE
DRAWING IS FULL SIZE AND THE DRAWING SCALES ACCURATE WHEN THE LENGTH OF THIS LINE IS TWO INCHES. IF THE LENGTH
S0321 IS OTHER THAN TWO INCHES, DRAWING SCALES MUST BE ADJUSTED ACCORDINGLY.
PLAN TITLE ENVIRONMENTAL ENGINEERING AND CONSULTING
2. EXISTING AND ABANDONED IN -PLACE PIPING IS DESIGNATED BY SERVICE RATHER THAN MATERIAL TYPE. MATERIAL TYPE, IF 309 East Morehead Street, Suite 160, Charlotte, NC 28202
SCALE: 1/8" = 1'-0" KNOWN, APPEARS INSIDE THE PIPING CALLOUT BUBBLE. EXISTING PIPING MATERIAL MAY NOT BE THE SAME MATERIAL TYPE (704) 358-7204
DISCIPLINE CODE (SEE LISTING ON THIS SPECIFIED FOR NEW PIPING. North Carolina Board of Examiners for Engineers and
DRAWING) Surveyors License No. F-0785
3. ABBREVIATIONS USED IN THIS CONTRACT DOCUMENT CONFORM TO ANSI Y1.1, UNLESS NOTED OTHERWISE ON DRAWINGS. SEE
SPECIFICATION SECTION 01 42 19 FOR ADDITIONAL ABBREVIATIONS.
2. SECTION
D CUTS: 4. ALL STANDARD DETAILS APPLY TO ALL THE DESIGN -BUILDER'S WORK WHETHER SPECIFICALLY REFERENCED OR NOT. D
6. TYPICAL DETAIL TITLES:
TYPICAL DETAIL NUMBER 5. SEE FRONT END SHEETS FOR EACH DISCIPLINES STANDARD SYMBOLS, ETC.
SECTION NUMBER 6. SEE ADDITIONAL GENERAL NOTES THROUGHOUT DRAWING SET. NOT FOR CONSTRUCTION
DETAIL TITLE FOR REVIEW ONLY
S0321 N.T.S. FACILITY DESIGNATION
3
G-000-003 PROCESS AREA DRAWING
NUMBER NUMBERING SYSTEM DESCRIPTION
7. KEYNOTES:
DRAWING WHERE / 0000 000 Main Office
SECTION IS SHOWN 4 0010 001 Miscellaneous
0070 007 Generator & Power Distribution
0080 008 Maintenance Shop & Vehicle Fuel Tank
0090 009 Administration & Lab �1111 I I I //2022-2-1
0100 010 Main Pump Station & Septic Haulers `\\'(\A CARO
3. DETAIL CALLOUT: PIPING IDENTIFICATION SYSTEM 0200 020 Headworks
0300 030 Primary Clarifiers .'FESS/0 • 2
0400 040 Aeration 9 `9
—DETAIL LETTER TO BE 0500 050 Secondary Clarifier
NUMBERED SEQUENTIALLY 6" DS - DI NEW PIPING 0600 060 Disinfection & NPW = .a SEAL
A. BY CALLOUT: THROUGHOUT THE ENTIRE r
/
DISCIPLINE 0700 070 Blower Building _ 036485
PIPE MATERIAL, 0800 080 Influent Flow EQ & NEF ��
3 WHERE UTILIZED MATERIAL AND SERVICE 1100 110 RAS Pump Stations & Metering Vaults p NG NEB ;�Q.
G-000-003 PIPE SERVICE ABBREVIATIONS 1200 120 WAS Pump Station7
— — — PIPE SIZE (SEE PIPE ABBREVIATIONS) 1400 140 Imported Biosolids Handling Facility //j�� SOS P
1500 150 Dewatering
I 6" DS - DI EXISTING PIPING 1600 160 Incinerator
DRAWING WHERE DETAIL (SEE GENERAL NOTE 2) 1700 170 Odor Control
C IS FOUND 1800 180 Heat Recovery Steam Generation FOR PERMITTING C
I 1900 190 Ash Pond & Pump Station
2000 200 Biosolids Ash Placement
I
I 6" DS - MD FUTURE PIPING
IWSACC
ABANDONED PIPING IN -PLACE
6" DS - DI (ABANDONM:)
(SEE GENERAL NOTE 2)
B. BY NOTE: "SEE DETAIL D-000-101" R 14001,24 + NC StarNbiic kv QIf SAS 1$0OIR
B IS DETAIL REFERENCE LETTER
D-000-101 IS DRAWING WHERE DETAIL IS SHOWN
ROCKY RIVER
MISCELLANEOUS REGIONAL
WASTEWATER
4. ENLARGED PLAN TITLES: TRUE NORTH TREATMENT PLANT
PLAN MATCH LINE
o NORTH -- -- 0 PHASE 3 EXPANSION
/ S E E D RAW I N G X-XXX-XXX REVISION TAG
ENLARGED PLAN NUMBER
M / REVISIONS
REV DATE DESCRIPTION
/ ABOVE GRADE BELOW GRADE
B 1 ENLARGED PLAN TITLE NEW/PROPOSEDLINEWORK B
Q G-0 000 01 SCALE: 1 /4" = V-0"
NORTH ARROW ABOVE GRADE BELOW GRADE
X
w EXISTING LINEWORK
c
DRAWING WHERE ENLARGED
d VIEW IS REFERENCED
PHOTO NUMBER
C)
E —_
m 1 REVISION CLOUD
� D-000-000
WATER SURFACE
5. SECTIONS TITLES: LINE IS 2 INCHES
DRAWING WHERE AT FULL SIZE
PHOTO IS LOCATED LOCATION EL XXXX.XX
OILDESIGNED: D. LOZINSKI
SECTION NUMBER TO BE NUMBERED EL XXXX.XX
SEQUENTIALLY THROUGHOUT THE ENTIRE PHOTO INDICATOR DRAWN: K. BRYAN
o_ DISCIPLINE ELEVATION CALL OUT IN PIPE CENTERLINE ELEVATION CALL CHECKED: P. SCHULER
SECTION OUT IN SECTION
°D DEMOLITION HATCHING CHECKED: B. ELEAZER
3 SECTION TITLE APPROVED: G. ANIPSITAKIS
G-000-003 SCALE: 1 /8" = 1'-0" FILENAMED RAW I N G NUMBERING SYSTEM 156673-G-00v19. rvt
Y
U
O
IY BC PROJECT NUMBER
I DRAWING WHERE SECTION IS DISCIPLINES 156673
CUT M-000-101 C CGE
IVNL RAL CLIENT PROJECT NUMBER
L0 6. DETAIL TITLES:
\ �7 A ARCHITECTURAL
SEQUENTIAL NUMBER S STRUCTURAL GENERAL
CD D PROCESS
co
2_ \ SHEET TYPE M MECHANICAL/HVAC
DETAIL LETTER P PLUMBING
\� AREA I INSTRUMENTATION
A E ELECTRICAL TYPICAL D RAW I N G A
DISCIPLINE FA FIRE ALARM
A DETAIL TITLE XD DEMOLITION(X- DENOTESDISCIPLINE)
Q CONVENTION
G-000-003 SCALE: 1 /8" = 1'-0"
o SHEET TYPE
4 0 GENERAL
0
— 1 PLANS
DRAWING WHERE DETAIL IS
N 2 ELEVATIONS
N CALLED 3 SECTIONS
N 5 DETAILS DRAWING NUMBER
04 6 SCHEDULES AND DIAGRAMS
6 9 3D REPRESENTATION G-000-101
76
0
SHEET NUMBER
0 3
d
1 2 3 4 5 6