Loading...
HomeMy WebLinkAbout20220827 Ver 1_ePCN Application_20220616Pre -Construction Notification (PCN) Form For Nationwide Permits and Regional General Permits (along with corresponding Water Quality Certifications) April 13, 2022 Ver 4.3 Initial Review Has this project met the requirements for acceptance in to the review process?* OO Yes 0 No Is this project a public transportation project?* OYes 0No Change only if needed. Pre -Filing Meeting Date Request was submitted on: 9/21/2021 BIMS # Assigned* Version# * 20220827 1 Is a payment required for this project?* 0 No payment required O Fee received O Fee needed - send electronic notification Reviewing Office* Winston-Salem Regional Office - (336) 776- 9800 Information for Initial Review What amout is owed?* O $240.00 0 $570.00 Select Project Reviewer* Sue Homewood:eads\slhomewood la. Name of project: Lowes Blvd Mebane NC la. Who is the Primary Contact?* David Cooper 1b. Primary Contact Email:* dcooper@vhb.com Date Submitted 6/16/2022 Nearest Body of Water Little Haw Creek Basin Cape Fear Water Classification WS-V;NSW Site Coordinates Latitude: 36.067551 A. Processing Information Longitude: -79.305614 lc. Primary Contact Phone:* (919)741-5784 County (or Counties) where the project is located: Alamance Is this a NCDMS Project Yes C• No Is this project a public transportation project?* O Yes •. No la. Type(s) of approval sought from the Corps: EI Section 404 Permit (wetlands, streams and waters, Clean Water Act) O Section 10 Permit (navigable waters, tidal waters, Rivers and Harbors Act) Has this PCN previously been submitted?* 0 Yes O No 1b. What type(s) of permit(s) do you wish to seek authorization? O Nationwide Permit (NWP) 0 Regional General Permit (RGP) 0 Standard (IP) lc. Has the NWP or GP number been verified by the Corps? 0Yes ®No Nationwide Permit (NWP) Number: NWP Numbers (for multiple NWPS): 1d. Type(s) of approval sought from the DWR: EO 401 Water Quality Certification - Regular 0 Non-404 Jurisdictional General Permit 0 Individual 401 Water Quality Certification 39 - Commercial/Institutional Developments le. Is this notification solely for the record because written approval is not required? For the record only for DWR 401 Certification: For the record only for Corps Permit: If. Is this an after -the -fact permit application?* O Yes O No O 401 Water Quality Certification - Express Op Riparian Buffer Authorization lg. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? O Yes O No 1g. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? O Yes O No lh. Is the project located in any of NC's twenty coastal counties? O Yes O No 1j. Is the project located in a designated trout watershed? OYes 0No B. Applicant Information 0Yes ONo OYes 0No Id. Who is applying for the permit? O Owner O Applicant (other than owner) le. Is there an Agent/Consultant for this project?* 0 Yes 0 No 2. Owner Information 2a. Name(s) on recorded deed: DRPBS Hospitality LLC 2b. Deed book and page no.: 2c. Contact Person: 2d. Address Street Address 5772 New Castle Lane Address Line 2 City Bettendorf Postal / Zip Code 52722 State / Province / Region IA Country USA 2e. Telephone Number: (563)676-0992 2f. Fax Number: 2g. Email Address: * radpandit@gmail.com 4. Agent/Consultant (if applicable) 4a. Name: David Cooper 4b. Business Name: VHB 4c. Address Street Address 940 Main Campus Drive Address Line 2 Suite 500 City Raleigh Postal / Zip Code 27606 4d. Telephone Number: (919)741-5784 4f. Email Address: * dcooper@vhb.com C. Project Information and Prior Project History State / Province / Region NC Country USA 4e. Fax Number: 1. Project Information lb. Subdivision name: Of appropriate) lc. Nearest municipality / town: Mebane 2. Project Identification 2a. Property Identification Number: 160533 2c. Project Address Street Address Lot 1 NC 119 Hwy Address Line 2 City Mebane Postal / Zip Code 27302 3. Surface Waters 3a. Name of the nearest body of water to proposed project: * Little Haw Creek 3b. Water Resources Classification of nearest receiving water: * WS-V;NSW 3c. What river basin(s) is your project located in?* Cape Fear 3d. Please provide the 12-digit HUC in which the project is located. 030300020407 4. Project Description and History 2b. Property size: 7.87 State / Province / Region NC Country USA 4a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: * The parcel is currently wooded. Streams and a pond on and adjacent to the site are subject to the Jordan Lake riparian buffer rules. All streams on or adjacent to the site and shown on either the USGS quad or soil survey are considered subject. 4b. Have Corps permits or DWR certifications been obtained for this project (including all prior phases) in the past?* 0 Yes CO No 0 Unknown 4f. List the total estimated acreage of all existing wetlands on the property: 0.095 4g. List the total estimated linear feet of all existing streams on the property: 95 4h. Explain the purpose of the proposed project:* The purpose of this project is to construct hotels and office/retail space on the proposed parcel located at the end of Lowes Blvd in Mebane, NC. 4i. Describe the overall project in detail, including indirect impacts and the type of equipment to be used: * The purpose of this project is to construct hotels and office/retail space on the proposed parcel located at the end of Lowes Blvd in Mebane, NC. The parcel is located adjacent to and south of Hwy 40/85, between exits 152 and 153. The parcel is currently wooded. Streams and a pond on and adjacent to the site are subject to the Jordan Lake riparian buffer rules. All streams on or adjacent to the site and shown on either the USGS quad or soil survey are considered subject. Riparian buffers will be avoided to the extent practicable. Buffer avoidance has been discussed with Summit Design and Engineering Services (Summit) and the site plan has been modified to move a roadway out of the riparian buffer. At this time, it is anticipated that grading and revegetation with grass in Zone 2 to be the only activities permanently affecting the buffer. Diffuse flow has also been discussed, and the site will install riprap dissipater pads at pipes which outlet outside of the buffer, as well as a grassed swale in another area. No stream or pond impacts are proposed. One small jurisdictional wetland will be impacted by construction. 5. Jurisdictional Determinations 5a. Have the wetlands or streams been delineated on the property or proposed impact areas?* ® Yes Comments: One small jurisdictional wetland will be impacted by construction. 0 No 5b. If the Corps made a jurisdictional determination, what type of determination was made? * O Preliminary O Approved O Not Verified O Unknown C N/A Corps AID Number: SAW-2018-01858 5c. If 5a is yes, who delineated the jurisdictional areas? Name (if known): Agency/Consultant Company: Other: David Cooper VHB 0 Unknown 5d. List the dates of the Corp jurisdiction determination or State determination if a determination was made by the Corps or DWR Jurisdictional status of streams and wetlands were verified by David Bailey of the USAGE on July 5, 2018. 6. Future Project Plans 6a. Is this a phased project?* O Yes O No Are any other NWP(s), regional general permit(s), or individual permits(s) used, or intended to be used, to authorize any part of the proposed project or related activity? No. D. Proposed Impacts Inventory 1. Impacts Summary la. Where are the impacts associated with your project? (check all that apply): I Wetlands 0 Open Waters 2. Wetland Impacts Streams -tributaries 0 Pond Construction OO Buffers 2a. Site #* (?) 2a1 Reason (?) 2b. Impact type* (?) 2c. Type of W.* 2d. W. name 2e. Forested* 2f. Type of Jurisdicition* (?) 2g. Impact area* 1 Fill P Hardwood Flat WA Yes Both 0.078 (acres) 2g. Total Temporary Wetland Impact 0.000 2g. Total Wetland Impact 0.078 2g. Total Permanent Wetland Impact 0.078 2i. Comments: Impact to one entire wetland is necessary for the site plan. 6. Buffer Impacts (for DWR) 6a. Project is in which protect basin(s)? Check all that apply. O Neuse 0 Catawba O Goose Creek O Other O Tar -Pamlico O Randleman O Jordan Lake 6b. Impact Type 6c. Per or Temp 6d. Stream name 6e. Buffer mitigation required? 6f. Zone 1 impact 6g. Zone 2 impact Exempt P SA No 0 910 Exempt P SC No 0 1,814 Exempt P SA Pond No 0 1,501 Exempt T SA Pond No 0 459 6h. Total buffer impacts: Total Temporary impacts: Total Permanent impacts: Total combined buffer impacts: Zone 1 0.00 Zone 1 0.00 Zone 1 0.00 Zone 2 459.00 Zone 2 4,225.00 Zone 2 4,684.00 6i. Comments: Impacts to Zone 1 are avoided entirely. Zone 2 impacts consist of grading and revegetation. A temporary impact for a skimmer basin outlet is also proposed, which will be removed and the area revegetated following construction. This area is also included in the Zone 2 grading/revegetation calculations for SA Pond in the table above. E. Impact Justification and Mitigation 1. Avoidance and Minimization la. Specifically describe measures taken to avoid or minimize the proposed impacts in designing the project: The initial site design was reviewed to identify areas where impacts could be minimized. A roadway was re-routed in order to avoid additional buffer impacts. Stormwater outlets were moved out of the buffer zones, and all Zone 1 impacts were avoided. lb. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques: Slopes in the vicinity of buffers and streams are as steep as feasible to minimize impacts. A retaining wall was discussed to further minimize impacts, but was rejected due to cost and safety. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? O Yes ® No 2b. If this project DOES NOT require Compensatory Mitigation, explain why: The project impacts are under the mitigation threshold for NWP 39. F. Stormwater Management and Diffuse Flow Plan (required by DWR) 1. Diffuse Flow Plan la. Does the project include or is it adjacent to protected riparian buffers identified within one of the NC Riparian Buffer Protection Rules? U Yes O No What type of SCM are you providing? O Level Spreader El Vegetated Conveyance (lower SHWT) O Wetland Swale (higher SHWT) OO Other SCM that removes minimum 30% nitrogen O Proposed project will not create concentrated stormwater flow through the buffer 2. Stormwater Management Plan 2a. Is this a NCDOT project subject to compliance with NCDOT's Individual NPDES permit NCS000250?* 0Yes ®No 2b. Does this project meet the requirements for low density projects as defined in 15A NCAC 02H .1003(2)? 0 Yes • No 2c. Does this project have a stormwater management plan (SMP) reviewed and approved under a state stormwater program or state -approved local government stormwater program? O Yes • No O N/A - project disturbs < 1 acre 3. Stormwater Requirements 3a. Select whether a completed stormwater management plan (SMP) is included for review and approval or if calculations are provided to document the project will not cause degradation of downstream surface waters.* O Stormwater Management Plan 0 Antidegradation Calculations Comments: Stormwater management is included in the construction drawings. G. Supplementary Information 1. Environmental Documentation la. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land?* Yes • No 2. Violations (DWR Requirement) 2a. Is the site in violation of DWR Water Quality Certification Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), or DWR Surface Water or Wetland Standards or Riparian Buffer Rules (15A NCAC 2B .0200)?* Yes O No 3. Cumulative Impacts (DWR Requirement) 3a. Will this project result in additional development, which could impact nearby downstream water quality?* Yes • No 3b. If you answered "no," provide a short narrative description. The surrounding area is already developed and the proposed project is one of the last remaining areas of forested land. The project is not expected to increase surrounding development. 4. Sewage Disposal (DWR Requirement) 4a. Is sewage disposal required by DWR for this project?* • Yes No N/A 4b. Describe, in detail, the treatment methods and dispositions (non -discharge or discharge) of wastewater generated from the proposed project. If the wastewater will be treated at a treatment plant, list the capacity available at that plant. The project will tie in to existing sanitary sewer. 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or habitat?* Yes • No 5b. Have you checked with the USFWS concerning Endangered Species Act impacts?* Yes • No 5d. Is another Federal agency involved?* Yes 5e. Is this a DOT project located within Division's 1-8? 0Yes ®No • No Unknown 5f. Will you cut any trees in order to conduct the work in waters of the U.S.? OYes 0No 5g. Does this project involve bridge maintenance or removal? OYes 0No 5h. Does this project involve the construction/installation of a wind turbine(s)?* 0Yes ®No 5i. Does this project involve (1) blasting, and/or (2) other percussive activities that will be conducted by machines, such as jackhammers, mechanized pile drivers, etc.? GYes 0No 5j. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? On September 27, 2021, after reviewing the IPaC species list for the project area, the NC Natural Heritage Program Data Explorer report for the project area, and making on -site habitat evaluations, we determined that biological conclusions of No Effect are appropriate for the three ESA federally protected or proposed species shown in the IPaC database as occurring in Alamance County: Cape Fear shiner (Endangered), Atlantic pigtoe (Proposed Threatened), and Schweinitz's sunflower (Endangered). Additionally, the project is adjacent to a small pond, but no bald eagle nests are located on the parcel and no Bald and Golden Eagle Act permit is required. 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as an Essential Fish Habitat?* 0 Yes O No 6b. What data sources did you use to determine whether your site would impact an Essential Fish Habitat?* NOAA Fisheries Essential Fish Habitat Mapper 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation status?* G Yes O No 7b. What data sources did you use to determine whether your site would impact historic or archeological resources?* NC State Historic Preservation Office's GIS Maps and Data. 8. Flood Zone Designation (Corps Requirement) 8a. Will this project occur in a FEMA-designated 100-year floodplain?* 0 Yes ® No 8c. What source(s) did you use to make the floodplain determination?* This project is not within a FEMA-designated 100-year floodplain, per FIRM Panel 9804. Miscellaneous Please use the space below to attach all required documentation or any additional information you feel is helpful for application review. Documents should be combined into one file when possible, with a Cover Letter, Table of Contents, and a Cover Sheet for each Section preferred. Click the upload button or drag and drop files here to attach document SupportinglnformationSubmittal.pdf 44.35MB File must be PDF or KMZ Comments Signature U By checking the box and signing below, I certify that: • The project proponent hereby certifies that all information contained herein is true, accurate, and complete to the best of my knowledge and belief'; and • The project proponent hereby requests that the certifying authority review and take action on this CWA 401 certification request within the applicable reasonable period of time. • I have given true, accurate, and complete information on this form; I agree that submission of this PCN form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); I understand that an electronic signature has the same legal effect and can be enforced in the same way as a written signature; AND I intend to electronically sign and submit the PCN form. Full Name: David G. Cooper Signature Date 6/16/2022 June 16, 2022 Mr. Chris Hopper U.S. Army Corps of Engineers Raleigh Regulatory Field Office 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 www.vhb.com Mr. Ryan Conchilla N.C. Division of Water Resources Winston-Salem Regional Office 450 West Hanes Mill Road, Suite 300 Winston-Salem, NC 27105 Subject: Pre -construction Notification Construction of Hotel and Office/Retail Space at the end of Lowes Blvd in Mebane, NC Mr. Hopper and Mr. Conchilla: VHB, on behalf of Summit Design and Engineering Services, respectfully requests review of the attached information, provided in support of the Pre -construction Notification for the above referenced hotel and office/retail space construction project. We have enclosed the following information to assist with your review: 1. USGS Vicinity Map 2. Soil Survey Map 3. Project Permit Drawings 4. Approved Jurisdictional Determination 5. Project Construction Drawings 6. DWR Pre -Filing Meeting Request Form Thank you for your assistance with this project. If you have any questions or need additional information, please contact David Cooper at dcooper@vhb.com (919) 741-5784. Sincerely, David Cooper Senior Environmental Scientist cc: William Wirt, PE, Summit Design and Engineering Services Engineers I Scientists I Planners I Designers Venture I 940 Main Campus Drive, Suite 500 Raleigh, North Carolina 27606 P 919.829.0328 F 919.833.0034 ATTACHMENT 1: USGS VICINITY MAP USGS VICINITY MAP MEBANE HOTEL LOWES BLVD. ALAMANCE COUNTY MAY 2018 ATTACHMENT 2: SOIL SURVEY MAP Prepared By: ‘14EdSsiii b SOILS MAP MEBANE HOTEL LOWES BLVD. ALAMANCE COUNTY MAY 2018 1960 NRCS Alamance County Soil Survey Map Sheets 16 & 20 NOTE: Streams shown on soil survey in the vicinity of the Study Area were hand digitized on this figure due to poor resolution of map image. N Figure 2 ATTACHMENT 3: PROJECT PERMIT DRAWINGS 40 & g5 STREAM "C" END OF 3-WIRE FENCE 3-WIRE FENCE IN DILAPIDATED CONDITION RUNS WITH ❑ 48" RCP INVsoR22' ,! SI4IV WIYN&W IBLEBOOT) Stream C Buffer Impact Zone 2 Grading/Revegetation 58 SF Igo ',-.41111611rA vow oawirr" I�r i Stream C Buffer Impact EBAR Stream p Zone 2 Grading/Revegetation 1,756 SF WETLAND "A" Pond A Buffer Impact Zone 2 Grading/Revegetation 1,024 SF OP Wetland A Impact 0.078 acre. XI IF ao�s Pond A Buffer Impact Zone 2 Grading/Revegetation 18 SF Legend Zone 2 Buffer r Impacts, Grading & Revegetation: 3,708 SF Wetland Impact: 0.078 ac. Buffer Zone 1 Buffer Zone 2 Limits of Disturbance Streams Pond A Shoreline z Wetland B (No r, Impact) 616 WETLAND "B" SS MH som.. Pond A Buffer Impact Temp.Skimmer Basin Outlet, Perm. Zone 2 Grading/Revegetation 459 SF dOPS • Stream A Buffer Impact Zone 2 Grading/Revegetation 910 SF STREAM"A" ti Prepared By: PERMIT IMPACT MAP MEBANE HOTEL LOWES BLVD. ALAMANCE COUNTY JUNE 2022 Based on construction drawings prepared by Summit Design Engineers, PA N 1 Figure 1 of 1 ATTACHMENT 4: APPROVED JURISDICTIONAL DETERMINATION SAW-2018-01858 Property Owner: Address: U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action Id. SAW-2018-01858 County: Alamance U.S.G.S. Quad: NC- Mebane NOTIFICATION OF JURISDICTIONAL DETERMINATION Ecological Engineering Attn: David Cooper 1151 SE Cary Parkway, Suite 101 Cary, NC 27518 Size (acres) —7.87 Nearest Town Mebane Nearest Waterway UT to Back Creek River Basin Cape Fear USGS HUC 03030002 Coordinates 36.067402 N,-79.305407 W Location description: The project area, shown as the red -outlined "Study Area" on the attached figure entitled "Stream & Wetland Sketch Map", is located on the south side of I-40/85, at the western terminus of Lowes Boulevard, in Mebane, Alamance County, North Carolina. PIN # 9804937529. Indicate Which of the Following Apply: A. Preliminary Determination ❑ There appear to be waters including wetlands, on the above described project area/property, that may be subject to Section 404 of the Clean Water Act (CWA)(33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). The waters including wetlands, have been delineated, and the delineation has been verified by the Corps to be sufficiently accurate and reliable. The approximate boundaries of these waters are shown on the enclosed delineation map dated DATE. Therefore this preliminary jurisdiction determination may be used in the permit evaluation process, including determining compensatory mitigation. For purposes of computation of impacts, compensatory mitigation requirements, and other resource protection measures, a permit decision made on the basis of a preliminary JD will treat all waters and wetlands that would be affected in any way by the permitted activity on the site as if they are jurisdictional waters of the U.S. This preliminary determination is not an appealable action under the Regulatory Program Administrative Appeal Process (Reference 33 CFR Part 331). However, you may request an approved JD, which is an appealable action, by contacting the Corps district for further instruction. ❑ There appear to be waters including wetlands, on the above described project area/property, that may be subject to Section 404 of the Clean Water Act (CWA)(33 USC § 1344) and/or Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403). However, since the waters including wetlands, have not been properly delineated, this preliminary jurisdiction determination may not be used in the permit evaluation process. Without a verified wetland delineation, this preliminary determination is merely an effective presumption of CWA/RHA jurisdiction over all of the waters including wetlands, at the project area, which is not sufficiently accurate and reliable to support an enforceable permit decision. We recommend that you have the waters including wetlands, on your project area/property delineated. As the Corps may not be able to accomplish this wetland delineation in a timely manner, you may wish to obtain a consultant to conduct a delineation that can be verified by the Corps. B. Approved Determination ❑ There are Navigable Waters of the United States within the above described project area/property subject to the permit requirements of Section 10 of the Rivers and Harbors Act (RHA) (33 USC § 403) and Section 404 of the Clean Water Act (CWA)(33 USC § 1344). Unless there is a change in law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. ® There are waters including wetlands, on the above described project area/property subject to the permit requirements of Section 404 of the Clean Water Act (CWA) (33 USC § 1344). Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. ❑ We recommend you have the waters including wetlands, on your project area/property delineated. As the Corps may not be able to accomplish this wetland delineation in a timely manner, you may wish to obtain a consultant to conduct a delineation that can be verified by the Corps. ® The waters including wetlands, on your project area/property have been delineated and the delineation has been verified by the Corps. The approximate boundaries of these waters are shown on the enclosed delineation map dated 7/1/2018. We strongly suggest you have this delineation surveyed. Upon completion, this survey should be reviewed and verified by the Corps. Once verified, this survey will provide an accurate depiction of all areas subject to CWA SAW-2018-01858 jurisdiction on your property which, provided there is no change in the law or our published regulations, may be relied upon for a period not to exceed five years. ❑ The waters including wetlands, have been delineated and surveyed and are accurately depicted on the plat signed by the Corps Regulatory Official identified below on DATE. Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. ❑ There are no waters of the U.S., to include wetlands, present on the above described project area/property which are subject to the permit requirements of Section 404 of the Clean Water Act (33 USC 1344). Unless there is a change in the law or our published regulations, this determination may be relied upon for a period not to exceed five years from the date of this notification. ❑ The property is located in one of the 20 Coastal Counties subject to regulation under the Coastal Area Management Act (CAMA). You should contact the Division of Coastal Management in Morehead City, NC, at (252) 808-2808 to determine their requirements. Placement of dredged or fill material within waters of the US, including wetlands, without a Department of the Army permit may constitute a violation of Section 301 of the Clean Water Act (33 USC § 1311). Placement of dredged or fill material, construction or placement of structures, or work within navigable waters of the United States without a Department of the Army permit may constitute a violation of Sections 9 and/or 10 of the Rivers and Harbors Act (33 USC § 401 and/or 403). If you have any questions regarding this determination and/or the Corps regulatory program, please contact David E. Bailey at 919-554-4884 extension 30 or D av i d. E. B ai le y 2 (d,u s ace. a rm y. m i 1. C. Basis For Determination: See the Approved Jurisdictional Determination form dated 10/31/2018. D. Remarks: None. E. Attention USDA Program Participants This delineation/determination has been conducted to identify the limits of Corps' Clean Water Act jurisdiction for the particular site identified in this request. The delineation/determination may not be valid for the wetland conservation provisions of the Food Security Act of 1985. If you or your tenant are USDA Program participants, or anticipate participation in USDA programs, you should request a certified wetland determination from the local office of the Natural Resources Conservation Service, prior to starting work. F. Appeals Information (This information applies only to approved jurisdictional determinations as indicated in B. above) This correspondence constitutes an approved jurisdictional determination for the above described site. If you object to this determination, you may request an administrative appeal under Corps regulations at 33 CFR Part 331. Enclosed you will find a Notification of Appeal Process (NAP) fact sheet and request for appeal (RFA) form. If you request to appeal this determination you must submit a completed RFA form to the following address: US Army Corps of Engineers South Atlantic Division Attn: Jason Steele, Review Officer 60 Forsyth Street SW, Room 10M15 Atlanta, Georgia 30303-8801 In order for an RFA to be accepted by the Corps, the Corps must determine that it is complete, that it meets the criteria for appeal under 33 CFR part 331.5, and that it has been received by the Division Office within 60 days of the date of the NAP. Should you decide to submit an RFA form, it must be received at the above address by 12/30/2018. **It is not necessary to submit an RFA form to the Division Office if you do not object to the determination in this correspondence. * * Digitally signed by BAILEY.DAVID.E.1379283736 DN: c=US, o=U.S. Govemment, ou=DoD, ou=PII, ou=USA, cn=BAILEY.DAVID.E.1379283736 Date: 2018.10.31 15:57:00-04'00' Corps Regulatory Official: Date of JD: 10/31/2018 Expiration Date of JD: 10/30/2023 The Wilmington District is committed to providing the highest level of support to the public. To help us ensure we continue to do so, please complete the Customer Satisfaction Survey located at http://corpsmapu.usace.army.mil/cm apex/f?p=136:4:0 Copy furnished: Sue Homewood, NCDEQ-DWR, 450 W. Hanes Mill Rd, Suite 300, Winston-Salem, NC 27105 WB-01 TIE TO POND Stream C, Subject to Jordan Buffer Rules. / / / / / / / / / /' / / / / / / / / I\ I\ �/ \I it ;\ I \ \ /// 1 IItNET, 1" = 60' • se -rig \ /1------' /,'' Legend Study Area 4 Perennial Stream C3 Pond Wetland \I \ Pond A, Not Flagged Please locate edge of water within 50' of project area. Pond is subject to Jordan Buffer Rules. Wetland located outside NCDOT ROW fence, Not Flagged. Wetland A (See Inset) Wetland B (See Inset) Stream A, Subject to Jordan Buffer Rules. s\i'N \ i `I I �� —/ N. SA-01 N / ��\ �N. / — NOTES: 1. Jurisdictional status of streams and wetlands were verified by David Bailey of the USACE on July 5, 2018. 2. Field delineations performed by Ecological Engineering on May 24, 2018. 3. All features shown are sketched approximately. This is not a survey. Prepared By: ECOLOGICAL ENGINEERING STREAM & WETLAND SKETCH MAP MEBANE HOTEL LOWES BLVD. ALAMANCE COUNTY JULY 2018 2014 NCOneMap Aerial NCDOT Contours N Figure 3 SAW-2018-01858 NOTIFICATION OF ADMINISTRATIVE APPEAL OPTIONS AND PROCESS AND REQUEST FOR APPEAL Applicant: Ecological Engineering (Attn: David Cooper) I File Number: SAW-2018-01858 Date: 10/31/2018 Attached is: See Section below ❑ INITIAL PROFFERED PERMIT (Standard Permit or Letter of permission) A ❑ PROFFERED PERMIT (Standard Permit or Letter of permission) B ❑ PERMIT DENIAL C APPROVED JURISDICTIONAL DETERMINATION D ❑ PRELIMINARY JURISDICTIONAL DETERMINATION E SECTION Additional or I - The following identifies your rights and options regarding an administrative appeal of the above decision. information may be found at or http://www.usace.army.mil/Missions/CivilWorks/RegulatoryProgramandPermits.aspx the Corps regulations at 33 CFR Part 331. i A: INITIAL PROFFERED PERMIT: You may accept or object to the permit. • ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. • OBJECT: If you object to the permit (Standard or LOP) because of certain terms and conditions therein, you may request that the permit be modified accordingly. You must complete Section II of this form and return the form to the district engineer. Your objections must be received by the district engineer within 60 days of the date of this notice, or you will forfeit your right to appeal the permit in the future. Upon receipt of your letter, the district engineer will evaluate your objections and may: (a) modify the permit to address all of your concerns, (b) modify the permit to address some of your objections, or (c) not modify the permit having determined that the permit should be issued as previously written. After evaluating your objections, the district engineer will send you a proffered permit for your reconsideration, as indicated in Section B below. B: PROFFERED PERMIT: You may accept or appeal the permit • ACCEPT: If you received a Standard Permit, you may sign the permit document and return it to the district engineer for final authorization. If you received a Letter of Permission (LOP), you may accept the LOP and your work is authorized. Your signature on the Standard Permit or acceptance of the LOP means that you accept the permit in its entirety, and waive all rights to appeal the permit, including its terms and conditions, and approved jurisdictional determinations associated with the permit. • APPEAL: If you choose to decline the proffered permit (Standard or LOP) because of certain terms and conditions therein, you may appeal the declined permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. C: PERMIT DENIAL: You may appeal the denial of a permit under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the division engineer. This form must be received by the division engineer within 60 days of the date of this notice. D: APPROVED JURISDICTIONAL DETERMINATION: You may accept or appeal the approved JD or provide new information. • ACCEPT: You do not need to notify the Corps to accept an approved JD. Failure to notify the Corps within 60 days of the date of this notice, means that you accept the approved JD in its entirety, and waive all rights to appeal the approved JD. • APPEAL: If you disagree with the approved JD, you may appeal the approved JD under the Corps of Engineers Administrative Appeal Process by completing Section II of this form and sending the form to the district engineer. This form must be received by the division engineer within 60 days of the date of this notice. SAW-2018-01858 E: PRELIMINARY JURISDICTIONAL DETERMINATION: You do not need to respond to the Corps regarding the preliminary JD. The Preliminary JD is not appealable. If you wish, you may request an approved JD (which may be appealed), by contacting the Corps district for further instruction. Also you may provide new information for further consideration by the Corps to reevaluate the JD. SECTION II - REQUEST FOR APPEA ' CTIONS TO AN INITIAL PROFFERED PERMIT REASONS FOR APPEAL OR OBJECTIONS: (Describe your reasons for appealing the decision or your objections to an initial proffered permit in clear concise statements. You may attach additional information to this form to clarify where your reasons or objections are addressed in the administrative record.) ADDITIONAL INFORMATION: The appeal is limited to a review of the administrative record, the Corps memorandum for the record of the appeal conference or meeting, and any supplemental information that the review officer has determined is needed to clarify the administrative record. Neither the appellant nor the Corps may add new information or analyses to the record. However, you may provide additional information to clarify the location of information that is already in the administrative record. POINT OF CONTACT FOR QUESTIONS OR INFORMATION: If you have questions regarding this decision and/or the If you only have questions regarding the appeal process you may also contact: Mr. Jason Steele, Administrative Appeal Review Officer CESAD-PDO U.S. Army Corps of Engineers, South Atlantic Division 60 Forsyth Street, Room 10M15 Atlanta, Georgia 30303-8801 Phone: (404) 562-5137 appeal process you may contact: District Engineer, Wilmington Regulatory Division Attn: David E. Bailey Raleigh Regulatory Office U.S Army Corps of Engineers 3331 Heritage Trade Drive, Suite 105 Wake Forest, North Carolina 27587 RIGHT OF ENTRY: Your signature below grants the right of entry to Corps of Engineers personnel, and any government consultants, to conduct investigations of the project site during the course of the appeal process. You will be provided a 15 day notice of any site investigation, and will have the opportunity to participate in all site investigations. Date: Telephone number: Signature of appellant or agent. For appeals on Initial Proffered Permits send this form to: District Engineer, Wilmington Regulatory Division, Attn: David E. Bailey, 69 Darlington Avenue, Wilmington, North Carolina 28403 For Permit denials, Proffered Permits and Approved Jurisdictional Determinations send this form to: Division Engineer, Commander, U.S. Army Engineer Division, South Atlantic, Attn: Mr. Jason Steele, Administrative Appeal Officer, CESAD-PDO, 60 Forsyth Street, Room 10M15, Atlanta, Georgia 30303-8801 Phone: (404) 562-5137 APPROVED JURISDICTIONAL DETERMINATION FORM U.S. Army Corps of Engineers This form should be completed by following the instructions provided in Section IV of the JD Form Instructional Guidebook. SECTION I: BACKGROUND INFORMATION A. REPORT COMPLETION DATE FOR APPROVED JURISDICTIONAL DETERMINATION (JD): October 31, 2018 B. DISTRICT OFFICE, FILE NAME, AND NUMBER: Wilmington District, Mebane Hotel site / Lowes Boulevard / Mebane / Alamance County / commercial, SAW-2018-01858 C. PROJECT LOCATION AND BACKGROUND INFORMATION: The project area is located on the south side of I-40/85, at the western terminus of Lowes Boulevard, in Mebane, Alamance County, North Carolina. PIN # 9804937529. State: North Carolina County/parish/borough: Alamance County City: Mebane Center coordinates of site (lat/long in degree decimal format): Lat. 36.0674021748497°N, Long. -79.3054074147499° W Universal Transverse Mercator: 17 652606.42 3992753.24 Name of nearest waterbody: UT to Back Creek Name of nearest Traditional Navigable Water (TNW) into which the aquatic resource flows: Name of watershed or Hydrologic Unit Code (HUC): Haw, 03030002 ® Check if map/diagram of review area and/or potential jurisdictional areas is/are available upon request. ❑ Check if other sites (e.g., offsite mitigation sites, disposal sites, etc...) are associated with this action and are recorded on a different JD form: D. REVIEW PERFORMED FOR SITE EVALUATION (CHECK ALL THAT APPLY): ❑ Office (Desk) Determination. Date: ® Field Determination. Date(s): 7/5/2018 SECTION II: SUMMARY OF FINDINGS A. RHA SECTION 10 DETERMINATION OF JURISDICTION. There Are "navigable waters of the U.S." within Rivers and Harbors Act (RHA) jurisdiction (as defined by 33 CFR part 329) in the review area. [Required] ❑ Waters subject to the ebb and flow of the tide. ❑ Waters are presently used, or have been used in the past, or may be susceptible for use to transport interstate or foreign commerce. Explain: B. CWA SECTION 404 DETERMINATION OF JURISDICTION. There • "waters of the U.S." within Clean Water Act (CWA) jurisdiction (as defined by 33 CFR part 328) in the review area. [Required] 1. Waters of the U.S. a. Indicate presence of waters of U.S. in review area (check all that apply): i ❑ TNWs, including territorial seas ❑ Wetlands adjacent to TNWs ® Relatively permanent waters2 (RPWs) that flow directly or indirectly into TNWs ❑ Non-RPWs that flow directly or indirectly into TNWs ▪ Wetlands directly abutting RPWs that flow directly or indirectly into TNWs ® Wetlands adjacent to but not directly abutting RPWs that flow directly or indirectly into TNWs ❑ Wetlands adjacent to non-RPWs that flow directly or indirectly into TNWs ® Impoundments of jurisdictional waters ❑ Isolated (interstate or intrastate) waters, including isolated wetlands b. Identify (estimate) size of waters of the U.S. in the review area: Non -wetland waters: 95 linear feet, 6 wide, and/or 0.01 acres. Wetlands: 0.04 acres. c. Limits (boundaries) of jurisdiction based on: Elevation of established OHWM (if known): 2. Non -regulated waters/wetlands (check if applicable):3 ❑ Potentially jurisdictional waters and/or wetlands were assessed within the review area and determined to be not jurisdictional. Explain: SECTION HI: CWA ANALYSIS A. TNWs AND WETLANDS ADJACENT TO TNWs 1 Boxes checked below shall be supported by completing the appropriate sections in Section III below. For purposes of this form, an RPW is defined as a tributary that is not a TNW and that typically flows year-round or has continuous flow at least "seasonally" (e.g., typically 3 months). 3 Supporting documentation is presented in Section III.F. -2- The agencies will assert jurisdiction over TNWs and wetlands adjacent to TNWs. If the aquatic resource is a TNW, complete Section III.A.1 and Section III.D.1. only; if the aquatic resource is a wetland adjacent to a TNW, complete Sections IILA.1 and 2 and Section IILD.1.; otherwise, see Section IILB below. 1. TNW Identify TNW: Summarize rationale supporting determination: 2. Wetland adjacent to TNW Summarize rationale supporting conclusion that wetland is "adjacent": B. CHARACTERISTICS OF TRIBUTARY (THAT IS NOT A TNW) AND ITS ADJACENT WETLANDS (IF ANY): This section summarizes information regarding characteristics of the tributary and its adjacent wetlands, if any, and it helps determine whether or not the standards for jurisdiction established under Rapanos have been met. The agencies will assert jurisdiction over non -navigable tributaries of TNWs where the tributaries are "relatively permanent waters" (RPWs), i.e. tributaries that typically flow year-round or have continuous flow at least seasonally (e.g., typically 3 months). A wetland that directly abuts an RPW is also jurisdictional. If the aquatic resource is not a TNW, but has year-round (perennial) flow, skip to Section IILD.2. If the aquatic resource is a wetland directly abutting a tributary with perennial flow, skip to Section III.D.4. A wetland that is adjacent to but that does not directly abut an RPW requires a significant nexus evaluation. Corps districts and EPA regions will include in the record any available information that documents the existence of a significant nexus between a relatively permanent tributary that is not perennial (and its adjacent wetlands if any) and a traditional navigable water, even though a significant nexus finding is not required as a matter of law. If the waterbody4 is not an RPW, or a wetland directly abutting an RPW, a JD will require additional data to determine if the waterbody has a significant nexus with a TNW. If the tributary has adjacent wetlands, the significant nexus evaluation must consider the tributary in combination with all of its adjacent wetlands. This significant nexus evaluation that combines, for analytical purposes, the tributary and all of its adjacent wetlands is used whether the review area identified in the JD request is the tributary, or its adjacent wetlands, or both. If the JD covers a tributary with adjacent wetlands, complete Section IILB.1 for the tributary, Section IILB.2 for any onsite wetlands, and Section 111.B.3 for all wetlands adjacent to that tributary, both onsite and offsite. The determination whether a significant nexus exists is determined in Section III.0 below. 1. Characteristics of non-TNWs that flow directly or indirectly into TNW (i) General Area Conditions: Watershed size: 83 Ees Drainage area: 31 Average annual rainfall: 46.6 inches Average annual snowfall: 8.6 inches (ii) Physical Characteristics: (a) Relationship with TNW: ❑ Tributary flows directly into TNW. ® Tributary flows through I tributaries before entering TNW. (b) Project waters are Project waters are Project waters are Project waters are river miles from TNW. (or less) river miles from RPW. (or less) aerial (straight) miles from TNW. • List aerial (straight) miles from RPW. Project waters cross or serve as state boundaries. Explain: Identify flow route to TNW5: Stream A (UT to Back Creek, RPW) to UT to Back Creek (RPW), to UT to Back Creek (RPW), to Back Creek (RPW), to Haw River (TNW) Tributary stream order, if known: 1st General Tributary Characteristics (check all that apply): ' Note that the Instructional Guidebook contains additional information regarding swales, ditches, washes, and erosional features generally and in the arid West. 5 Flow route can be described by identifying, e.g., tributary a, which flows through the review area, to flow into tributary b, which then flows into TNW. -3- Tributary is: ® Natural ® Artificial (man-made). Explain: Portion of Stream A subject to wetland adjacency review is impounded (Pond A) by a man-made earthen berm dam. ❑ Manipulated (man -altered). Explain: Tributary properties with respect to top of bank (estimate): Average width: 5 feet Average depth: 1 feet Average side slopes: E. Primary tributary substrate composition (check all that apply): ® Silts ® Sands ❑ Cobbles ® Gravel ❑ Bedrock ❑ Vegetation. Type/% cover: ❑ Other. Explain: ❑ Concrete ❑ Muck Tributary condition/stability [e.g., highly eroding, sloughing banks]. Explain: stable Presence of run/riffle/pool complexes. Explain: present above portion impounded as Pond A. Tributary geometry: Tributary gradient (approximate average slope): 1 % (c) Flow: Tributary provides for: Estimate average number of flow events in review area/year: Describe flow regime: Perennial Other information on duration and volume: Surface flow is: Characteristics: Due to relatively small watershed, Stream A appears to be primarily confined to its banks Subsurface flow: -. Explain findings: ❑ Dye (or other) test performed: Tributary has (check all that apply): ® Bed and banks OHWM6 (check all indicators that apply): ® clear, natural line impressed on the bank ® changes in the character of soil ® shelving ® vegetation matted down, bent, or absent ® leaf litter disturbed or washed away ® sediment deposition ❑ water staining ❑ other (list): ❑ Discontinuous OHWM.7 Explain: ❑ the presence of litter and debris ❑ destruction of terrestrial vegetation ❑ the presence of wrack line ® sediment sorting ❑ scour ® multiple observed or predicted flow events ❑ abrupt change in plant community If factors other than the OHWM were used to determine lateral extent of CWA jurisdiction (check all that apply): ❑ High Tide Line indicated by: ❑ Mean High Water Mark indicated by: ❑ oil or scum line along shore objects ❑ survey to available datum; ❑ fine shell or debris deposits (foreshore) ❑ physical markings; ❑ physical markings/characteristics ❑ vegetation lines/changes in vegetation types. ❑ tidal gauges ❑ other (list): (iii) Chemical Characteristics: Characterize tributary (e.g., water color is clear, discolored, oily film; water quality; general watershed characteristics, etc.). Explain: Water was clear on day of site visit. Identify specific pollutants, if known: Drainage area receives water from impervious parking lots and state -maintained roads; as such, petrochemicals from road and parking lot runoff are likely. 6A natural or man-made discontinuity in the OHWM does not necessarily sever jurisdiction (e.g., where the stream temporarily flows underground, or where the OHWM has been removed by development or agricultural practices). Where there is a break in the OHWM that is unrelated to the waterbody's flow regime (e.g., flow over a rock outcrop or through a culvert), the agencies will look for indicators of flow above and below the break. 'Ibid. -4- (iv) Biological Characteristics. Channel supports (check all that apply): ® Riparian corridor. Characteristics (type, average width): >300 feet on south side, no greater than 50 feet on north and east sides.: primarily deciduous forest ® Wetland fringe. Characteristics: Wetland fringe is present in narrow corridor on both sides of Stream A near impoundment (Pond A). ® Habitat for: ❑ Federally Listed species. Explain findings: ® Fish/spawn areas. Explain findings: Stream is large enough for small fish, as is Pond A. ❑ Other environmentally -sensitive species. Explain findings: ® Aquatic/wildlife diversity. Explain findings: Water source for common urban-wildland interface species. 2. Characteristics of wetlands adjacent to non-TNW that flow directly or indirectly into TNW (i) Physical Characteristics: (a) General Wetland Characteristics: Properties: Wetland size: 0.03 (Wetland A) acres Wetland type. Explain: PFO Wetland quality. Explain: medium -high Project wetlands cross or serve as state boundaries. Explain: (b) General Flow Relationship with Non-TNW: Flow is: . Explain: Flow through wide natural swale during precipitation events. Surface flow is: Characteristics: Sheet flow from wetlandsthrough wide natural swale during precipitation events. Subsurface flow: —. Explain findings: ❑ Dye (or other) test performed: (c) Wetland Adjacency Determination with Non-TNW: ❑ Directly abutting ® Not directly abutting ® Discrete wetland hydrologic connection. Explain: Flow from Wetland A to Pond A through wide natural swale during precipitation events. Evidence includes hydric soils and a clay aquitard --6" deep continuing from the S end of Wetland A to the edge of Pond A. Wetland A and Pond A are seperated by only—30 LE ❑ Ecological connection. Explain: ❑ Separated by berm/barrier. Explain: (d) Proximity (Relationship) to TNW Project wetlands are 2-5 river miles from TNW. Project waters are aerial (straight) miles from TNW. Flow is from: Estimate approximate location of wetland as within the or greater floodplain. (ii) Chemical Characteristics: Characterize wetland system (e.g., water color is clear, brown, oil film on surface; water quality; general watershed characteristics; etc.). Explain: No surface water present in Wetland A on day of site visit, though water stained leaves were present. Identify specific pollutants, if known: None noted (iii) Biological Characteristics. Wetland supports (check all that apply): ® Riparian buffer. Characteristics (type, average width): This wetland is within 30 l.f. of the edge of Pond A, an impoundment of Stream A. ® Vegetation type/percent cover. Explain: 90% cover, mature deciduous forest. ® Habitat for: ❑ Federally Listed species. Explain findings: ❑ Fish/spawn areas. Explain findings: ® Other environmentally -sensitive species. Explain findings: Slight depressional landform would allow shallow seasonal ponding of water, which would provide excellent amphibian breeding habitat due to absense of fish. ® Aquatic/wildlife diversity. Explain findings: Cover habitat for common urban-wildland interface species. 3. Characteristics of all wetlands adjacent to the tributary (if any) -5- All wetland(s) being considered in the cumulative analysis: Approximately 0.04 acres in total are being considered in the cumulative analysis. For each wetland, specify the following: Directly abuts? (Y/N) Wetland A (N) Size (in acres) 0.03 Directly abuts? (Y/N) Wetland B (Y) Size (in acres) 0.01 Summarize overall biological, chemical and physical functions being performed: Wetland A and others in similar landscape (saddle/depressional) positions receive preciptation-derived water, retain water, allow biogeochemical anaerobic processes (i.e. denitrification) to occur to improve water quality, and serve as groundwater recharge areas. These depressional-type wetlands serve as breeding habitat for sensitive species such as amphibians, as well as seasonal water sources for a variety of typical wildland/urban interface wildlife species. C. SIGNIFICANT NEXUS DETERMINATION A significant nexus analysis will assess the flow characteristics and functions of the tributary itself and the functions performed by any wetlands adjacent to the tributary to determine if they significantly affect the chemical, physical, and biological integrity of a TNW. For each of the following situations, a significant nexus exists if the tributary, in combination with all of its adjacent wetlands, has more than a speculative or insubstantial effect on the chemical, physical and/or biological integrity of a TNW. Considerations when evaluating significant nexus include, but are not limited to the volume, duration, and frequency of the flow of water in the tributary and its proximity to a TNW, and the functions performed by the tributary and all its adjacent wetlands. It is not appropriate to determine significant nexus based solely on any specific threshold of distance (e.g. between a tributary and its adjacent wetland or between a tributary and the TNW). Similarly, the fact an adjacent wetland lies within or outside of a floodplain is not solely determinative of significant nexus. Draw connections between the features documented and the effects on the TNW, as identified in the Rapanos Guidance and discussed in the Instructional Guidebook. Factors to consider include, for example: • Does the tributary, in combination with its adjacent wetlands (if any), have the capacity to carry pollutants or flood waters to TNWs, or to reduce the amount of pollutants or flood waters reaching a TNW? • Does the tributary, in combination with its adjacent wetlands (if any), provide habitat and lifecycle support functions for fish and other species, such as feeding, nesting, spawning, or rearing young for species that are present in the TNW? • Does the tributary, in combination with its adjacent wetlands (if any), have the capacity to transfer nutrients and organic carbon that support downstream foodwebs? • Does the tributary, in combination with its adjacent wetlands (if any), have other relationships to the physical, chemical, or biological integrity of the TNW? Note: the above list of considerations is not inclusive and other functions observed or known to occur should be documented below: 1. Significant nexus findings for non-RPW that has no adjacent wetlands and flows directly or indirectly into TNWs. Explain findings of presence or absence of significant nexus below, based on the tributary itself, then go to Section III.D: 2. Significant nexus findings for non-RPW and its adjacent wetlands, where the non-RPW flows directly or indirectly into TNWs. Explain findings of presence or absence of significant nexus below, based on the tributary in combination with all of its adjacent wetlands, then go to Section III.D: 3. Significant nexus findings for wetlands adjacent to an RPW but that do not directly abut the RPW. Explain findings of presence or absence of significant nexus below, based on the tributary in combination with all of its adjacent wetlands, then go to Section III.D: Wetland A is hydrologically connected to Pond A (impoundment of Stream A [RPW]) through a natural wide swale, that directs water from the wetland to the impoundment due to general topographic relief and a shallow (6" deep) clay aquitard). This wetland area has the capability to receive precipitation -derived water and treat this water through anaerobic processes before either recharging groundwater or releasing via the above -referenced swale into Pond A. These actions limit nutrient input into Pond A which drains out via overflow-outfall structure into Haw River in less than 5 river miles via Back Creek and 2 of its unnamed tributaries. As such, Wetland A and similarly situate wetlands affect the chemical, physical, and biological integrity of, and has a significant nexus with, the Haw River, a TNW. Note also that the Haw River flows directly into Jordan Lake, a public water supply. D. DETERMINATIONS OF JURISDICTIONAL FINDINGS. THE SUBJECT WATERS/WETLANDS ARE (CHECK ALL THAT APPLY): -6- 1. TNWs and Adjacent Wetlands. Check all that apply and provide size estimates in review area: ❑ TNWs: linear feet, wide, Or acres. ❑ Wetlands adjacent to TNWs: acres. 2. RPWs that flow directly or indirectly into TNWs. ® Tributaries of TNWs where tributaries typically flow year-round are jurisdictional. Provide data and rationale indicating that tributary is perennial: Stream A is not within the review area (not included in waters estimate below), but was located just to the south of the review area, and thus allowed evaluation during the site visit. This feature displayed flow during the dry period of the year (summer), and the consultant noted tlow during his earlier site visit as well. See also the OHWM indicators noted in Section III.B.(ii)(c). Note also that Pond A is an impoundment of Stream A, via an earthen berm dam with swpillway/water control structure. Stream C is within the review area, flows out of an NCDOT culvert under I-40/85, ocupies a man -altered channel along the review area boundary, and was determined to be perennial by the consultant. ❑ Tributaries of TNW where tributaries have continuous flow "seasonally" (e.g., typically three months each year) are jurisdictional. Data supporting this conclusion is provided at Section III.B. Provide rationale indicating that tributary flows seasonally: Provide estimates for jurisdictional waters in the review area (check all that apply): ® Tributary waters: 95 linear feet 6 wide. ® Other non -wetland waters: 0.1 acres. Identify type(s) of waters: Pond A is an impoundment of Stream A, via an earthen berm dam with swpillway/water control structure. 3. Non-RPWs8 that flow directly or indirectly into TNWs. ❑ Waterbody that is not a TNW or an RPW, but flows directly or indirectly into a TNW, and it has a significant nexus with a TNW is jurisdictional. Data supporting this conclusion is provided at Section III.C. Provide estimates for jurisdictional waters within the review area (check all that apply): ❑ Tributary waters: linear feet, wide. ❑ Other non -wetland waters: acres. Identify type(s) of waters: 4. Wetlands directly abutting an RPW that flow directly or indirectly into TNWs. ® Wetlands directly abut RPW and thus are jurisdictional as adjacent wetlands. ® Wetlands directly abutting an RPW where tributaries typically flow year-round. Provide data and rationale indicating that tributary is perennial in Section III.D.2, above. Provide rationale indicating that wetland is directly abutting an RPW: Wetland B extends to the banks of Stream A and Pond A. ❑ Wetlands directly abutting an RPW where tributaries typically flow "seasonally." Provide data indicating that tributary is seasonal in Section III.B and rationale in Section III.D.2, above. Provide rationale indicating that wetland is directly abutting an RPW: Provide acreage estimates for jurisdictional wetlands in the review area: 0.01 acres. 5. Wetlands adjacent to but not directly abutting an RPW that flow directly or indirectly into TNWs. ® Wetlands that do not directly abut an RPW, but when considered in combination with the tributary to which they are adjacent and with similarly situated adjacent wetlands, have a significant nexus with a TNW are jurisidictional. Data supporting this conclusion is provided at Section III.C. Provide acreage estimates for jurisdictional wetlands in the review area: 0.03 acres. 6. Wetlands adjacent to non-RPWs that flow directly or indirectly into TNWs. ❑ Wetlands adjacent to such waters, and have when considered in combination with the tributary to which they are adjacent and with similarly situated adjacent wetlands, have a significant nexus with a TNW are jurisdictional. Data supporting this conclusion is provided at Section III.C. Provide estimates for jurisdictional wetlands in the review area: acres. 7. Impoundments of jurisdictional waters.' As a general rule, the impoundment of a jurisdictional tributary remains jurisdictional. 'See Footnote # 3. 9 To complete the analysis refer to the key in Section III.D.6 of the Instructional Guidebook. -7- ® Demonstrate that impoundment was created from "waters of the U.S.," or ❑ Demonstrate that water meets the criteria for one of the categories presented above (1-6), or ❑ Demonstrate that water is isolated with a nexus to commerce (see E below). E. ISOLATED [INTERSTATE OR INTRA-STATE] WATERS, INCLUDING ISOLATED WETLANDS, THE USE, DEGRADATION OR DESTRUCTION OF WHICH COULD AFFECT INTERSTATE COMMERCE, INCLUDING ANY SUCH WATERS (CHECK ALL THAT APPLY):1° ❑ which are or could be used by interstate or foreign travelers for recreational or other purposes. ❑ from which fish or shellfish are or could be taken and sold in interstate or foreign commerce. ❑ which are or could be used for industrial purposes by industries in interstate commerce. ❑ Interstate isolated waters. Explain: ❑ Other factors. Explain: Identify water body and summarize rationale supporting determination: Provide estimates for jurisdictional waters in the review area (check all that apply): ❑ Tributary waters: linear feet, wide. ❑ Other non -wetland waters: acres. Identify type(s) of waters: ❑ Wetlaands: acres. F. NON -JURISDICTIONAL WATERS, INCLUDING WETLANDS (CHECK ALL THAT APPLY): ❑ If potential wetlands were assessed within the review area, these areas did not meet the criteria in the 1987 Corps of Engineers Wetland Delineation Manual and/or appropriate Regional Supplements. ❑ Review area included isolated waters with no substantial nexus to interstate (or foreign) commerce. ❑ Prior to the Jan 2001 Supreme Court decision in "SWANCC," the review area would have been regulated based solely on the "Migratory Bird Rule" (MBR). ❑ Waters do not meet the "Significant Nexus" standard, where such a finding is required for jurisdiction. Explain: ❑ Other: (explain, if not covered above): Provide acreage estimates for non -jurisdictional waters in the review area, where the sole potential basis of jurisdiction is the MBR factors (i.e., presence of migratory birds, presence of endangered species, use of water for irrigated agriculture), using best professional judgment (check all that apply): ❑ Non -wetland waters (i.e., rivers, streams): linear feet, wide. ❑ Lakes/ponds: acres. ❑ Other non -wetland waters: acres. List type of aquatic resource: ❑ Wetlands: acres. Provide acreage estimates for non -jurisdictional waters in the review area that do not meet the "Significant Nexus" standard, where such a finding is required for jurisdiction (check all that apply): ❑ Non -wetland waters (i.e., rivers, streams): linear feet, wide. ❑ Lakes/ponds: acres. ❑ Other non -wetland waters: acres. List type of aquatic resource: ❑ Wetlands: acres. SECTION IV: DATA SOURCES. A. SUPPORTING DATA. Data reviewed for JD (check all that apply - checked items shall be included in case file and, where checked and requested, appropriately reference sources below): ® Maps, plans, plots or plat submitted by or on behalf of the applicant/consultant: Aerial, soils, and topo maps, and photos (Ecological Engineering) ® Data sheets prepared/submitted by or on behalf of the applicant/consultant. ® Office concurs with data sheets/delineation report. ❑ Office does not concur with data sheets/delineation report. ❑ Data sheets prepared by the Corps: ❑ Corps navigable waters' study: ❑ U.S. Geological Survey Hydrologic Atlas: ❑ USGS NHD data. 10 Prior to asserting or declining CWA jurisdiction based solely on this category, Corps Districts will elevate the action to Corps and EPA HQ for review consistent with the process described in the Corps/EPA Memorandum Regarding CWA Act Jurisdiction Following Rapanos. -8- ❑ USGS 8 and 12 digit HUC maps. ® U.S. Geological Survey map(s). Cite scale & quad name: 1:24K; Mebane ® USDA Natural Resources Conservation Service Soil Survey. Citation: Alamance Co. Soil Survey ❑ National wetlands inventory map(s). Cite name: ❑ State/Local wetland inventory map(s): ❑ FEMA/FIRM maps: ❑ 100-year Floodplain Elevation is: (National Geodectic Vertical Datum of 1929) ® Photographs: ® Aerial (Name & Date): 2014 NCOneMap or ® Other (Name & Date): David Cooper (Ecological Engineering) 5/24/2018. ❑ Previous determination(s). File no. and date of response letter: ❑ Applicable/supporting case law: ❑ Applicable/supporting scientific literature: ® Other information (please specify): LiDAR (NC Floodmaps) B. ADDITIONAL COMMENTS TO SUPPORT JD: This JD form documents Stream A (RPW, not within the review area), Stream C (RPW), Pond A (impoundment of Stream A), Wetland B (abutting Stream A and Pond A), and Wetland A (adjacent to Pond A with significant nexus). ATTACHMENT 5: PROJECT CONSTRUCTION DRAWINGS to , N VICINITY MAP SITE INFORMATION SCALE 1" = 2,000' N i_ Q p OWNER/ DEVELOPER: RAD PANDIT CONSTRUCTION DRAWINGS DRPBS HOSPITALITY, LLC 5 5772 NEW CASTLE LANE BETTENDORF, IA 52722 muniIpE Q Ia ' (563)676-0992 e OD radpandit@gmail.com �0 IIII PIN: 9804-93-7529 FOR 1 Tanger OutL .__ PARCEL ID: 160533 CO '.1IIlrc I Fx' :,Thu!is ZC! LAND AREA: 7.12 ACRES PROPERTY H 57 ADDRESS: LOWES BLVD. MEBANE, NC 27302 DRPBS HOSPITALITY , LLC .. . ..„ _.. ,•• .,_, EXISTING ZONING: B-2 _r_,,..„: ._.„._•. ., , __ _ _ _ _ _• . _ _ _ _ _ _ _ _• . . �dd1m Louses Boulevard CURRENT USE: VACANT / za PROPOSED USE: COMMERCIAL - / 4 JURISDICTION: MEBANE STATE: NORTH CAROLINA LOWES BOULEVARD :,, 0- TOTAL DISTURBED AREA: 277,371 SF a BUILDING AREAS MEBANE, NC 27302 N.. . CON N- 2-HOTELS: 80,000 SF/EA(<5,000 SF MEErING SPACE)160,000 SF TOTAL 1- ` I RETAIL: 5,000 SF o QZ wz2 w 0 o�>�'OFFICE: 5,000 SF Ha4fields � zw wp�w¢= cn o Ozwx TOTAL: 170,000 SF _ - o Z< -Z-zFIRST SUBMITTAL: 1/25/2022 . - W m LL Z aU Jw¢0O BUILDING SETBACKS c,i z TOTAL:40' SECOND SUBMITTAL: 4/12/2022 0 oO ow¢ wzwJ 0 I -• _ • w w REAR: 30' Hc• H ¢WOa¢}OoDEMLR SUBMITTAL: 5/13/2022 • W , o Oxz = o MAX BUILDING HEIGHT: 70' �„ zzf zonxzz W ¢ Q z. W W 1-167_ ' PARKING O ¢�wnt REQUIRED: U cjoILD Z >COLUZZin Qw W awooz� ¢¢Op (nJJz.,cw— RETAIL: 1 SP/200 SF GFA 5,000 SF= 25 SPACES01 z w_, x o OFFICE: 1 SP/200 SF GFA 5,000 SF= 25 SPACES HOTEL: 1.25 SP/RENTAL UNIT ` `J 103&80 ROOMS=183 ROOMS=229 SPACES TOTAL: 279 SPACES DEVELOPER/OWNER ENGINEER CONTACT SURVEY CONTACT RAD PANDIT SUMMIT DESIGN&ENGINEERING SERVICES SUMMIT DESIGN&ENGINEERING SERVICES SHEET INDEX Uui ACCESSIBLE SPACES REQUIRED w 0 H. DRPBS HOSPITALITY, LCC TIMOTHY A. SMITH, PE BRANTLEY W.WELLS, PLS H o 7 TOTAL(INCLUDING 1 VAN SPACE) U O 2 5772 NEW CASTLE LANE 320 EXECUTIVE COURT 320 EXECUTIVE COURT = „J c� 2 BETTENDORF, IA 52722 HILLSBOROUGH, NC 27278 HILLSBOROUGH, NC 27278 Sheet PARKING SPACES PROVIDED RETAIUOFFICE= 50 SPACES (563)676-0992 (919)732-3883(PHONE) (919)732-3883(PHONE) N Sheet Title Number radpandit@gmail.com (919)732-6676(FAX) (919)732-6676(FAX) w w ¢ w HOTELS= 210 SPACES TIM.SMITH@SUMMITDE.NET BRANTLEY.WELLS@SUMMITDE.NET Z o w TOTAL SPACES= 260 SPACES CD = z a cn ¢p 260 INCLUDING 7 ACCESSIBLE SPACES 3 WHICH ARE VAN ACCESSIBLE COVER SHEET C-1 zLi, ~ Q r ¢ w NOTE:APPROVED SUP INCLUDES A REDUCTION IN REQUIRED PARKING H co. H m z coco OF 19 SPACES. N U U Z > ,_ o PUBLIC SERVICE CONTACTS : EXISTING CONDITIONS PLAN C-2 3 8 Q o ; x BIKE RACKS 0 REQUIRED WATER: CITY OF MEBANE PUBLIC WORKS DEPT. STATE ROADWAYS: NCDOT-DIVISION 7, DISTRICT 1 SLOPE ANALYSIS SHEET C-3 `a a I `.. i I RETAIUOFFICE= 2 KYLE SMITH CHARLES N. EDWARDS(CHUCK), PE HOTELS= 5 636 CORRIGIDOR STREET DISTRICT ENGINEER NOT FOR 1 TOTAL= 7 MEBANE, NC 27302 115 E. CRESCENT SQUARE DRIVE \\\\\�I I I I I I l d dd// ENERAL NOTES -4 -N ARo/;' PROVIDED: 7 (919)563-3401 PO BOX 766 \\` � GRAHAM, NC27253 SITE & UTILITY PLAN C-5 o� =� VEHICULAR USE AREA= 108,185 SF(ALL PARKING&DRIVE AISLES) SEWER: CITY OF MEBANE PUBLIC WORKS DEPT. (336)570-6833 �;' KYLE SMITH IMPERVIOUS AREA: 636 CORRIGIDOR STREET PLANNING: CITY OF MEBANE GRADING & STORM DRAINAGE PLAN _ N C-6 - • BUILDING: 39,554 MEBANE, NC 27302 CY STOBER,AICP = ► ' 7 ASPHALT: 106,965 (919)563-3401 CONCRETE: 106,96 DEVELOPMENT2 SEDIRECTOR " FIRE: CITYQFMEBANE SS OUTFACE 'A' & WATERLINE 1 PROFILES C-7 ?; '•fiGINE ••``��,'t TOTAL: 178,220 SF(4.09 AC) 57.46 /" MEBANE, NC 27302(919)563-9990 �0�- A.S�` ` BOB LOUIS,CHIEF WATERLINE 1 PROFILE C-8 450 N. FIRST STREET SOLID WASTE: CITY OF MEBANE PUBLIC WORKS DEPT. �//dll l l I II\��\ MEBANE, NC 27302 636 CORREGIDOR STREET (�_(� CONSTRUCTION} (919)563-5718 MEBANE, NC 27302 WATERLINE 2 PROFILES v 9 GAS: PSNC ENERGY/DOMINION ENERGY (919)563-3401 ti 1 BRIAN SMITH RECYCLING: WASTE INDUSTRIES CROSSING PIPES PROFILES C-10 v 2541 WHILDEN DRIVE 703 E. GILBREATH STREET DURHAM, NC 27713 GRAHAM, NC 27253 (919)598-7454 (336)229-0525 PRE-D EV. DRAINAGE MAP C-11 y BRIAN.SMITH@SCANA.COM EROSION CONTROL: DEMLR POST-DEV DRAINAGE MAP C-12 Nm = .0 ELECTRIC: DUKE ENERGY 450 WEST HANES MILL ROAD,SUIT 300, 1205 N.CHURCH STREET WINSTON-SALEM, NC 27105 = cv ENGINEERING CONSTRUCTION PLAN REVIEW & INSPECTION FEES: BURLINGTON, NC 27217 (336)776-9800 EROSION CONTROL PHASE I C-13 Z (336)538-1677 Z a TELEPHONE: AT&T EROSION CONTROL PHASE II C-14 Z STORMWATER MANAGEMENT FEES: AARON BOYKINS p a (336)508-3237 LANDSCAPING PLAN LS-1 co M 00 M 1. OVERALL PLAN REVIEW FOR COMPLIANCE = $2,500 diJ o -g N 2. REVIEW/ INSPECTION PER DEVICE AT $1,500 EACH X 2 DEVICES = $3,000 PARCEL SITE DETAILS D-1 z TOTAL = $6,500 PIN:9804937529 SITE, WATER & STORM DETAILS D-2 . ZONING: B-2 o STREET, STORM WATER & UTILITY INSPECTION FEES: 7.12ACREs 1 WATER AND SEWER DETAILS D-3 a �` s W .� v � Mx 'D 1. WATER MAIN 1,810 LF $2.50/LF = $4,525 .�, , ,, ,� a F ��.� ',., ` D-4 s R ;� r STORMWATER DETAILS 2. WATER SERVICES 3 BLDG. $500/BLDG = $1,500 v` ,.M ` Rp-« . . v.-y,, I; �. - _ , � 6I i it t 6� SCM DETAILS-WETPOND I D-5 3. SEWER MAIN 670 LF $2.50/LF = $1 675 �",,,„,„. "` Ari "'" ! e� . ' :4-4'-' r� ,"H T '� '' `" ` _ 1 0 erf 4. SEWER SERVICES 3BLDG. $500/BLDG = $1,500 ° } :- � ' »�p " r - „, t; , `-� - ,, r ` . , ��'� '. ° SCM DETAILS-WETPOND II D-6 5. SIDEWALK 283 LF $1.0/LF = $283 "" *� �� kl °I'� I f --,e,.m U r ^� 1 EROSION CONTROL DETAILS D-7 TOTAL = $9,483 _° a °d(1 � ,,, �' �. ---- _ ,, ITEMS REQUIRED TO BE PAID AT TIME OF FINAL CONSTRUCTION PLAN '' _ D-8 �� �~ It, ,:, ,j#:,-'7' � 4 ' EROSION CONTROL DETAILS-1 t�@ c,'�,a h re fir" 4«ti%5^ ,'y� ,. ' 'k , '-{APPROVAL, AND BEFORE INITIATION OF CONSTRUCTION OR RECORDATION M^ ,, „ . , ��--L� i .y> ,. OF FINAL PLAT. t,� ,., �� 1-' : - -41 a, ,I , j[ NCG01 GENERAL NOTES D-9A ` r ,1'1"� ` t � I NCG01 GENERAL NOTES D-9B u 1--1 ; s y ' ' ' = ',' TEMP SEDIMENT BASIN DETAILS D-10 Z a Sus ;4' BUILDING ELEVATIONS o � . , E.�� ,f, , ,t t. %/ -dl : BUILDING ELEVATIONS A401 A -� Z 0,,4' ' , 0 . tv ,-. 0 0 Z I— fir, 172a17 r r� 1 �n .� r ln;11d9 t,, C /\ W �' �� ��IT"�R�� Fx'f153 S?N AN' �I 1 r ,Wv p de _ 1. i,con.-cool. wp 2 Hawu`, i,llh s a, •+,.hit•`." r:,�.+ t — —54-r-ion iilf Y 3,n �� ='k1i AG �A, n - -172-;7., MW �/I O i -w�xl[tisx atf s(cn�v� f i5. nF h L J o pY '•' I� CO OQ a• .$�+u.a.R.r-,.. _ .-�-_.;K; -. I -1 a' CI W �°n � fi""ad ti9 �/ � Z win > T, �� { /0 "MEBANE / 1,1457 e 3 .? • pP s a'. 11111P U S TO + .,' SITE 1G,Y� \:� ^rye nJ i` - wl / S ,.k,* /Fr55 ,w f ' f. F ) "C i ��v ` / d° A l PROJECT NO. l' 1rstiqr i °; 23G, — 56 GV,--.7\ .. 4ss�R$ 1,fsa, DRAWING NAME: Ell ". .4::' ,,, / CONTRACTOR SHALL NOTIFY"NC811"(811)OR(1-800-632-4949)AT -" I 4 1„ia" ''''' g .1;1,,,2 fi 18-0156_CS.dwg kVr LEAST3FULLBUSINESSDAYSPRIORTOBEGINNINGCONSTRUCTION F " _>,, rt •4• / OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. SHEET NO. CONTHEIR CASHTLLCONTACTANYEOCAL PENDUNI OF THAT PROVIDE SITE LOCATION MAP MEBANE CITY LIMITS MAP THEIR OWN LOCATOR SERVICES INDEPENDENT OF"NC811". REPORT ^- Know what's below. ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. SCALE: 1" - 1000' /V Call before you dig. NTS J ACE 111_60,* B�A,IR 40 &'S5 LN��R5 RSABI.E WN WV 600 48" Rcp M.. 0 RAN MONUMENT CAP & RESAR GPIN 9804922987 PARCEL ID 1 70381 TOLLINGWOQD-HA WFIELDS LLC DS 2835/293 PS 73/102 I, BRANTLEY WELLS, PLS NO. 4544, CERTIFY THAT THE NC COORDINATE SYSTEM DATA SHOWN ON THIS PLAT WAS OBTAINED F-ROM AN ACTUAL GLOBAL NAVIGATION SATELLITE SYSTEM (CASS) SURVEY MADE UNDER MY SUPERVISION AND THE FOLLOWING INFORMATION WAS USED TO PERFORM THE SURVEY. 7) DATE(S) OF SURVEY: SEPTEMBER 25, 2018 2) TYPE OF GIBS FIELD PROCEDURE: VRS 3) CONTROL USED: HELD IRS STATIONS 4) HORIZONTAL DATUM/EPOCH: NAD 83/2011 5) VERTICAL DATUM: NAVE) 88 6) GEOID MODEL: GEOIDI20 7) COORDINATE SYSTEM: NC STATE PLANE (FIPS 32o0) 8) UNITS: US SURVEY FAT 9) COMBINED SCALE FACTOR: 0.99994821 SYMBOL LEGEND BENCHMARK 0 IRON PIN SET Q IRON PIN FOUND ■ MONUMENT FOUND E MONUMENT SET ilk CONIFEROUS TREE 0 DECIDUOUS TREE O ElOLARD F SIGN Re SANITARY CLEANOUT SANITARY MANHOLE r D HIRED END SECTION m. STORM INLET } STORM MANHOLE Li - ELECTRIC BOIL -G GUY WIRE ANCHOR LIGHT POLE # YARD LIGHT 0 POWER POLE 5 GAS METER ca °" GAS VALVE TE TELEPHONE i3Ox V FIRE HYDRANT 61 WATER METER 'A WATER VALVE ecr BACK FLOW PREVENTER PVC POLW1NYL CHLORIDE PIPE RCP REINFORCED CONCRETE PIPE DIP DUCTILE hRON PIPE C&G CURB AND GUTTER INV INVERT ELEV ELEVATION FENCE UNE x x WATER UNE - W OVERHEAD ELECTRIC UNE OH SANITARY UNE SA GAS LINE G PROPERTY UNE (SURVEYED) PROPERTY UNE (NOT SURVEYED) RIGHT OF WAY UNE — — EXISTING STORM PIPE NM MI INN M EXISTII1G TREE UNE STREAM "C" SEE NOW "M" 604. 1 FLOWS WORTHH II 11 r — N -1.°12 5 r ' 11 E. ZONE f (0' — 30') & ZONE 2 (30' - 50') JDRDAN BUFFER ON STREAM ZONE I (0" - 30' & ZONE 2 (30' - 50') JOfRDAN BUFFER ON POND "A" 1 END OF 3- WIRE FENCE 0 o g 3-WIRE FENCE IN DILAPIDATED CONDITION ---. - RUNS WITH ( f NO2 '08'09 "W 100.09' SHORELINE OF FOND "A", DIGITIZED FROM 0RTH-IORECTI'f QED AERIAL PHOTOGRAPHY WETLAND FOLLOWS DITCH LINE AND IS LOCATED INSIDE R/W SEE NOTE "M" 5-WIRE FENCE RUNS WITH R/W 48' RCP !NV. 600.14' _ f R/W MONUMENT Ef i GAP & f EDAR (CRIMPED).6 �r EIP S89'51'26"W 100.05' PROPERTY CORNER FALLS IN POND I HEREBY CERTIFY THAT THIS PLAT IS OF THE FOLLOWING TYPE: • NTIt55742"W 2 .51' R/W !MCNU ,IEN T CAP & REAR ri FLOWS N or1-1 N N N WETLAND "A" SEE NOTE "M" DP SHORELINE OF POND) "A", - AS SURVEYED POND "A" SEE NOTE "M" GPIN 9804922987 PARCEL f0 170381 TOLLINGVOOD---HAWHEW S LLC UB 2835/293 PB 73/102 G.S. 47-30 'F)(11)(C)(1). THIS SURVEY IS OF AN EXISTING PARCEL OR PARCELS OF LAND AND DOES NOT CREATE A NEW STREET OR CHANGE AN EXISTING STREET. 1, BRANTLEY W. WELLS, PLS NO. 4544, CERTIFY T144T THIS MAP WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION (DEED DESCRIPTION RECORDED W BOOK/PAGE: (AS NOTED HEREON) OR OTHER REFERENCE SOURCE (AS NOTED HEREON); THAT THE BOUNDARIES NOT SURVEYED ARE INDICATED IN A BROKEN UNETYPE AS DRAWN FROM INFORMATION IN BOOK/PAGE: (AS NOTED HEREON) OR OTHER REFERENCE SOURCE. (AS NOTED HEREON): THAT THE RATIO OF PRECISION OR POSITIONAL ACCURACY IS 170,000+; AND THAT THIS MAP MEETS THE REQUIREMENTS OF THE STANDARDS OF PRACTICE FOR LAND SURVEYING IN NORTH CAROLINA (21 NCAC 56. 1600). WITNESS MY ORIGINAL SIGNATURE. REGISTRATION NUMBER AND SEAL T -15 1ST DAY OF NOVEMBER, 20 18." `0,011iiiil l"if/ PROFESSi4T LAND SURVEYOR REG. NUMBER L-4544 SUI 1T DESIGN & ENGINEERING SERVICES, PLLC. REG. NUMBER P-0339 L47432.50' R=5555.20' CFI-N 79 52'41 "F CH. GIST 432.39' SS MH RAM ELEV. = 513.94' INV IN = 605.91' (8" VP) INV. OUT - 604.08' (8" VP) / k ti \ • GPIN 9804937529 - PARCEL- ID 160533 �. / JAN ISLEY RUMARKS . & ALBERT RUMARKS de Iva TON F BROWN III - deMARGARET I. BROWN DB 1981/659 PARCEL AREA 309,382 SO, FEET 7.102 ACRES 1.14 » � Ai 1 S89 5? 26"W 196.14' ROCK (SEE P8 66/,302) ty 5-WIRE FENCE RUNS WI77-I R/W • SI lad / J SIGf / WETLAND FOLLOWS DITCH LINE AND IS LOCATED INSIDE RfW SEE NOTE 'M" SIGN sp, / z J I / J / / {{/ #\ 7 FIP (CRIMPED) 7 -620 WETLAND "5' SEE NOTE N EP (CRIMPED) FOUND BENT AND LEANING JUNCTiON POINTS OF JORDAN BUFFERS FOR POND "A" AND .-- STREAlvf "A' 285. STREAM "A" sEE NOTE "M" SUBSURFACE AND ENVIRONMENTAL CONDITIONS WERE NOT EXAMINED OR CONSIDERED DURING THIS SURVEY. ALL BUILDINGS, SURFACE AND SUBSURFACE IMPROVEMENTS ON AND ADJACENT TO THE SITE ARE NOT NECESSARILY SHOWN HEREON. NO STATEMENT IS MADE CONCERNING THE EXISTENCE OF UNDERGROUND CON TAINERS WHICH MAY AFFECT THE USE OF TI-IIS TRACT. THE LOCATION OF UNDERGROUND UTILITIES AS SHOINN ARE BASED ON VISIBLE EVIDENCE AND DRAWINGS PROVIDED TO THE SURVEYOR. LOCATION OF UNDERGROUND UTILITIES AND STRUCTURES MAY VARY FROM LOCATIONS SHOWN HEREON, AND ADDITIONAL BURIED COMPANIES FOR INFORMATION REGARD/61G BURIED UTILITIES. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES. AREAS WERE DE TERMWED BY COORDINATE COMPUTATION. 17-IIS SURVEY WAS DONE WITHOUT A TER_E SEARCH AND IS BASED ON REFERENCED INFORMATION. THERE MAY EXIST OTHER DOCUMENTS OF RECORD WHICH COULD AFFECT 77-1IS PROPERTY. GROUND EIR • SS kik-I NC COORDINATE SYSTEM GRID de GROUND EnD FouNo PENT EIR FOUND BENT IP) 20.04' JORDAN BUFFER ON STRFAM EXCEPT AS SPECIFICALLY STATED OR SHOWN, THIS SURVEY DOES NOT REPORT ANY OF THE FOLLOWING: EASEMENTS,. OTHER THAN THOSE VISIBLE DURING FIELD EXAMINATION, BUILDING SETBACKS, RESTRICTIVE COVENANTS, ZONING OR LAND USE REGULATIONS AND ANY FACTS WHICH A TITLE SEARCH MAY DISCLOSE. WETLANDS, JURISDICTIONAL WATERS OR OTHER CONDI TIONS WHICH MAY EIE REGULATED BY FEDERAL OR STATE OR LOCAL AGENCIES WERE NOT INVESTIGATED DURING 11-If S SURVEY. RIPARIAN BUFFERS AND OTHER RESTRICTIONS ON DEVELOPMENT MAY BE REWIRED. SEE FINAL PLAT "CORPORATE LIMITS EXTENSION, CITY OF MEBANE" RECORDED W PLAT BOOK 66, PAGE 302. SEE ALSO DEED BOOK 686 PAGE 216, JOHN & VIS WILLIAMS (GRANTORS) TO NC DEPARTMENT OF TRANSPORTATION. DATED APRIL 10TH, 2015 AND NC DOT PROJECT 8.1500307 SHEET 4, NOTE "PI" NO NC GEODETIC SURVEY MONUMEN TS WERE FOUND 2000' OF THIS SITE. SAMTARY SEWER UNE. SEE PLA T BOOK PLAT FOR LOWS HOME CLIVIORS, FREELAND, PLS. PARCEL ID 163487 LOWES HOME CENTERS WC. • GPIN 9814031565 HARRY P ISLE Y Pe 68/376 EIR PAVEMENT CURB 248.50' EIR 0.08' SOUTH OF FOUND BENT IP EIR SPRING FOREST °R MINI-7-Y MAP NOT TO SCALE 301" RCP NORM CATCH ASW 10" PVC 8_ TRANSFORMER ON TPED MH • a000 ZONES ARE BASED ON GIS SHAPE FILES PROVIDED BY THE. NORTH CAROLINA FLOOD RISK INFORMATION SYSTEM (rFRIS), THIS INFORMATION CAN ALSO BE SEEN ON FIRM MAPS; MAP THIS PROPERTY IS WITHIN THE CAPE FEAR RIVER BASIN. ZONING MINIMUM LOT AREA MINIMUM LOT WIDTH MINIMUM FRONT SETBACK : B-2 GENERAL BUSINESS MINIMUM REAR SETBACK : 30 Fr REFERENCE: UNIFIED DEVELOPMENT ORDINANCE, arY OF MEBANE THE STREAMS MID WETLANDS SHOWN ON THIS PLAT WERE DELWEATED IN THE Flap BY ECOLOGICAL ENGINEERING (CARY, NC) ON MAY 24714, 2078, AND SUBSEQUENTLY LOCATED BY SUMMIT DESIGN & ENGINEERING SERVICES, ACCORDING TO 17-FE DELINEATION FLAGS AND MARKS PLACED BY IN THE FIELD ECOLOGICAL ENGINEERING. 1_,0147,cs ssot4v A _1) GRAPHIC SCALE 1 inch 50 ft. GS DATE CITY OF MEBANE COMMENTS REVISIONS ' . j G SERVICES DRAWING ALTERATION :21;:cLucu) 3°°<Lucc: M:<>1>-L)Luu) 00(1)cciujEcLu<— 121 zU -21°' 11-5LIC 760 021 _zD wo<cc toY ci ;52 tcog .<7,Ht iToz< L=0! 7inz Lizt i u:<zo - zoi - rPROJECT ENGINEER/ARCHITECT TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER WILLIAM.WIRT@SUMMITDE.COM 0 Ct FIRST ISSUE DATE c NOT FOR DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court oo cv Fax: (919) 732-6676 CV 3.1 1-4 CO 0 a_ 0 0 0 0 PROJECT NO. 18-0156 DRAWING NAME: SHEET NO. C-2 �N�N�GNB V PR\P R'w s3 \NIorvk P UG S'4.57,49"W — "148.52 GPIN 9804922987 PARCEL ID 170381 TOLLINGWOOD -HAWFIELDS LLC DB: 2835/293 PB: 73/102 VACANT COMMERCIAL LAND ZONING: M-2 I J ( 1 1 l 1 I 48" 1-RCP INV. 600.22' 5 45./4, GPIN 9804922987 PARCEL ID 170381 TOLLINGWOOD-HAWFIELDS LLC DB 2835/293 PB 73/102 VACANT COMMERCIAL LAND ZONING: M-2 FLOWS NORTH 8/• frA.N S'6 613— 48" RCP INV. 600.14' / 676� EXISTING POND 618� SS MH RIM ELEV. = 613.94' INV. IN = 605.91' (8" VP) INV. OUT = 604.08' (8" VP) 6 6 FLOWS NORTH / L=432.50' R=5655.20' CH=N79 52'41 "E CH. DIST=432.39' i SS/ 1 / r I / GPIN 9804937529 PARCEL LD 160533 DRPBS HOSPILITY LLC DB: 3827/260 AREA: 7.18 AC ZONING: B-2 I / CO WETLAND "B"- 7 SS S SS/ I 611E 7 / i / i co co / / / / / / z —\ �7 \� ;<"."---:----..'" \ \ate ��� 6\\ \676 \ / SS / / SS 0 / / / SS \\ FLOWS WEST SS SS MH RIM ELEV. = 624.83' INV. IN = 616.60' (8" VP) INV. OUT = 615.86' (8" VP) GPIN 9814037566 PARCEL ID 163487 LOWES HOME CENTERS INC. DB 2065/997 PB 68/376 DISCOUNT STORE ZONING: B-2 GPIN 9814031565 PARCEL ID 163482 HARRY P ISLEY & J. MACK ISLEY JR. DB 911/162 PB 68/376 VACANT -COMMERCIAL LAND ZONING: B-2 1 A Slopes Table Number Minimum Slope Maximum Slope Color 2D AREA 3D AREA 1 15.00% 24.99% 2919.11 2976.77 2 25.00% 100.00% 1783.05 1893.01 GPIN 9814026895 PARCEL ID 163481 COMPASS POINTE CENTER OWNERS ASSOC. DB 3387/540 PB 76/410 COMMERCIAL COMMON AREA ZONING: B-2, M-1 & M-2 ST MH ST MH 30" RCP FLOWS NORTH TPED CATCH BASIN 24" RCP TRANSFORMER ON CONCRETE PAD t I/VS St VD GS DATE CITY OF MEBANE COMMENTS REVISIONS ' . j ,21 G SERVICES DRAWING ALTERATION vipu_E°2- z0()_ x: :Ho _5_ <L>i. iLuZ2 o:WWW (2u 50: H_<5Ocizz> 5( =nza j:z°L ja (it nzu )196-1 urj2u uu )7° L. Liitz:L. u°H :7 'oil> u=c )2!L uc 01U _<EL U<LCZ U12 octi:<:57: )0:12L. uk7E-1 Lu PROJECT MANAGER GS (GOVINDA.SEDHAY@SUMMITDE.COM) FIRST ISSUE DATE NOT FOR DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court 00 Fax: (919) 732-6676 en oo oo ersnl 4t • 1-4 rzi z • cn r• :12 E-1 O eN co Lir co co 0 >- 0 PROJECT NO. DRAWING NAME: SHEET NO. GENERAL NOTES: 1. COMPLETENESS OR ACCURACY OF LOCATION AND DEPTH OF EXISTING UNDERGROUND UTILITIES AND STRUCTURES IS NOT GUARANTEED. 2. LOCATION OF ALL EXISTING AND PROPOSED SERVICES ARE APPROXIMATE AND SHALL BE CONFIRMED INDEPENDENTLY WITH LOCAL UTILITY COMPANIES AND NC811 PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION OR EXCAVATION. SANITARY SEWER AND ALL OTHER UTILITY SERVICE CONNECTION POINTS SHALL BE CONFIRMED INDEPENDENTLY BY THE CONTRACTOR IN THE FIELD PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. ALL DISCREPANCIES SHALL BE REPORTED IMMEDIATELY IN WRITING TO THE ENGINEER. CONSTRUCTION SHALL COMMENCE BEGINNING AT THE LOWEST INVERT (POINT OF CONNECTION) AND PROGRESS UP GRADIENT. PROPOSED CROSSINGS WITH EXISTING UNDERGROUND UTILITIES SHALL BE FIELD VERIFIED BY TEST PIT PRIOR TO COMMENCEMENT OF CONSTRUCTION. 3. AS SHOWN ON THE FLOOD INSURANCE RATE MAPS. PORTIONS OF THE SITE AREA PROPOSED TO BE DEVELOPED LIE WITHIN "ZONE X" DEFINED AS AREAS DETERMINED TO BE OUTSIDE THE 100 YEAR FLOOD PLAIN. 4. CONSTRUCTION/DEMOLITION; ALL CONSTRUCTION AND DEMOLITION CONDUCTED SHALL BE IN COMPLIANCE OF THE CURRENT EDITION OF CHAPTER 14 OF THE NC FPC. CONSTRUCTION AND GRADING NOTES: 1. ALL WORK SHALL COMPLY WITH APPLICABLE STATE, FEDERAL AND LOCAL CODES AND OSHA STANDARDS ALL NECESSARY LICENSES AND PERMITS SHALL BE OBTAINED BY THE CONTRACTOR AT HIS EXPENSE UNLESS PREVIOUSLY OBTAINED BY THE OWNER/DEVELOPER. 2. THE CONTRACTOR SHALL BE REQUIRED TO REVIEW AND ABIDE BY SPECIFICATIONS OF THE PLAN AND ALL SUPPORTING DOCUMENTS, PERMITS, AND REPORTS FOR THIS SITE, INCLUDING NOT BUT NOT LIMITED TO: EROSION AND SEDIMENTATION CONTROL PLAN STORMWATER MANAGEMENT PLAN. 3. THE CONTRACTOR SHALL IMMEDIATELY INFORM THE ENGINEER OF ANY DISCREPANCIES OR ERROR THEY DISCOVER IN THE PLANS. 4. DEVIATION FROM THESE PLANS AND NOTES WITHOUT THE PRIOR CONSENT OF THE OWNER OR HIS REPRESENTATIVE OR THE ENGINEER MAY BE CAUSE OF THE WORK TO BE UNACCEPTABLE. 5. UTILITY COORDINATION SHALL BE INCLUDED IN THE PROJECT SCHEDULE AND IT IS THE EXPLICIT RESPONSIBILITY OF THE CONTRACTOR TO ASSURE THAT THE PROJECT SCHEDULE INCLUDES THE NECESSARY RELOCATIONS. THE CONTRACTOR WILL NOT BE PAID ADDITIONALLY FOR THIS COORDINATION. THE CONTRACTOR SHOULD SEEK ASSISTANCE FROM ALL UTILITY COMPANIES TO LOCATE AND PROTECT THEIR FACILITIES. IF CONFLICTS ARE FOUND, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND DESIGN ENGINEER FOR INSTRUCTION BEFORE PROCEEDING WITH WORK. 6. ALL MATERIALS SHALL BE NEW UNLESS USED OR SALVAGED MATERIALS ARE SPECIFICALLY AUTHORIZED BY THE OWNER AND APPLICANT. 7. TRAFFIC CONTROL METHODS, SUCH AS BARRICADES, SUFFICIENT LIGHTS, SIGNS, ETC., MAY BE NECESSARY FOR THE PROTECTION AND SAFETY OF THE PUBLIC SHALL BE PROVIDED AND MAINTAINED THROUGHOUT THE CONSTRUCTION IN ACCORDANCE WITH CURRENT AND NCDOT STANDARDS. 8. CONTRACTOR SHALL FURNISH AND MAINTAIN ALL NECESSARY BARRICADES, FENCING AND OTHER APPROPRIATE SAFETY ITEMS/MEASURES NECESSARY TO PROTECT THE PUBLIC FROM THE WORK AREA CONSTRUCTION ACTIVITIES. 9. HIGH INTENSITY LIGHTING FACILITIES SHALL BE SO ARRANGED THAT THE SOURCE OF ANY LIGHT IS CONCEALED FROM PUBLIC VIEW AND FROM ADJACENT RESIDENTIAL PROPERTY AND DOES NOT INTERFERE WITH TRAFFIC. 10. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR EMERGENCY VEHICLES AROUND AND TO ALL BUILDINGS NEAR CONSTRUCTION. IN TIME OF RAIN OR MUD, ROADS SHALL BE ABLE TO CARRY A FIRE TRUCK BY BEING PAVED OR HAVING A CRUSHED STONE BASE, ETC. WITH A MINIMUM WIDTH OF 20 FEET. 11. BEDDING REQUIREMENTS SPECIFIED HEREIN ARE TO BE CONSIDERED AS MINIMUMS FOR RELATIVELY DRY, STABLE EARTH CONDITIONS. ADDITIONALLY BEDDING SHALL BE REQUIRED FOR ROCK TRENCHES AND WET AREAS. CONTRACTOR SHALL HAVE THE RESPONSIBILITY TO PROVIDE SUCH ADDITIONAL BEDDING AS MAY BE REQUIRED TO PROPERLY CONSTRUCT THE WORK. 12. BACKFILL OF ALL TRENCHES IN STRUCTURAL AREAS SHALL BE COMPACTED TO THE DENSITY OF 95% OF THEORETICAL MAXIMUM DRY DENSITY UP TO THE LAST 12" OF BACKFILL WHICH WILL BE COMPACTED TO 98% OF THE MAXIMUM DRY DENSITY (ASTM D698). BACKFILL MATERIAL SHALL BE FREE FROM ROOTS, STUMPS, OR OTHER FOREIGN DEBRIS AND SHALL BE PLACED IN LAYERS NOT TO EXCEED SIX (6) INCHES IN COMPACTED FILL THICKNESS. A REPORT FROM A GEOTECHNICAL ENGINEER MAY BE REQUIRED BY THE CITY INSPECTOR. CORRECTION OF ANY TRENCH SETTLEMENT WITHIN A YEAR FROM THE DATE OF APPROVAL WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 12. THE CONTRACTOR WILL ENSURE THAT POSITIVE AND ADEQUATE DRAINAGE IS MAINTAINED AT ALL TIMES WITHIN THE PROJECT LIMITS. THIS MAY INCLUDE, BUT NOT BE LIMITED TO, A) REPLACEMENT OR RECONSTRUCTION OF EXISTING DRAINAGE STRUCTURES THAT HAVE BEEN DAMAGED OR REMOVED, OR B) REGRADING AS REQUIRED BY THE ENGINEER, EXCEPT FOR THOSE DRAINAGE ITEMS SHOWN AT SPECIFIC LOCATIONS AND HAVING SPECIFIC PAY ITEMS IN THE DETAILED ESTIMATE. NO SEPARATE PAYMENT WILL BE MADE FOR ANY COSTS INCURRED TO COMPLY WITH THIS REQUIREMENT. 13. THE CONTRACTOR SHALL PROVIDE ANY AND ALL EXCAVATION AND MATERIAL SAMPLES NECESSARY TO CONDUCT REQUIRED SOIL TESTS. ALL ARRANGEMENTS AND SCHEDULING FOR THE TESTING SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 14. SOIL TESTING AND ON -SITE INSPECTION SHALL BE PERFORMED BY AN INDEPENDENT GEOTECHNICAL ENGINEER. A GEOTECHNICAL ENGINEER IS REQUIRED TO INSPECT, TEST AND CERTIFY TO THE COMPACTION OF ALL LOAD BEARING FILLS. THE GEOTECHNICAL ENGINEER SHALL PROVIDE COPIES OF TEST REPORTS TO THE CONTRACTOR, THE OWNER AND TO THE OWNER'S REPRESENTATIVE AND SHALL PROMPTLY NOTIFY THE OWNER, HIS REPRESENTATIVE AND THE CONTRACTOR, SHOULD WORK PERFORMED BY THE CONTRACTOR FAIL TO MEET THESE SPECIFICATIONS. 15. ALL PERMITS MUST BE OBTAINED PRIOR TO THE START OF CONSTRUCTION. 16. ALL PAVEMENT MARKINGS AND REGULATORY SIGNS SHALL CONFORM TO CURRENT MUTCD STANDARDS. 17. ALL DAMAGE TO PUBLIC OR PRIVATE MAINTAINED STREETS DUE TO PROJECT CONSTRUCTION WILL BE REPAIRED AT NO COST TO THE OWNER PRIOR TO ISSUANCE OF CERTIFICATE OF OCCUPANCY. 19. A PRECONSTRUCTION MEETING WITH THE GOVERNING MUNICIPALITY, GENERAL CONTRACTOR, GRADING AND UTILITY CONTRACTORS IS REQUIRED PRIOR TO START OF PROJECT CONSTRUCTION. 20. PRIOR TO ANY WORK IN THE STREET OR RIGHT-OF-WAYS OR SITE WORK IT WILL BE NECESSARY TO CONTACT THE CITY OF MEBANE INSPECTIONS DEPT. 21. ALL CASTINGS TO BE USED FOR WATER, SEWER AND STORM DRAINAGE SHALL BE DOMESTICALLY CAST. Know what's below. CaII before you dig. UTILITY NOTES: 1. ALL NEW UTILITIES SHALL BE LOCATED UNDERGROUND. 2. ALL PUBLIC UTILITIES AND CONNECTIONS TO PUBLIC UTILITIES SHALL CONFORM TO THE CITY OF MEBANE STANDARDS AND SPECIFICATIONS. 3. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ANY PERMITS NECESSARY FOR CONSTRUCTION. 4. PRIOR TO THE CONSTRUCTION OF ANY WATER OR SEWER MAIN EXTENSIONS, THE ENGINEER OF RECORD SHALL BE CONTACTED BY THE GENERAL CONTRACTOR TO DISCUSS CERTIFICATION REQUIREMENTS. FAILURE TO CONTACT THE ENGINEER OF RECORD OR PROVIDE ANY OF THE REQUESTED DOCUMENTATION DISCUSSED MAY RESULT IN THE INABILITY OF THE ENGINEER TO CERTIFY THE LINE AND PREVENT ACCEPTANCE OF UTILITIES BY CITY OF MEBANE. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF THE LOCATION AND/OR RELOCATION OF ALL EXISTING UTILITIES WITH THE APPROPRIATE UTILITY, AGENCY OR COMPANY. 6. THE CONTRACTOR SHALL COORDINATE ALL UTILITY CONNECTIONS AND DISTURBANCES WITH EXISTING USERS AND CITY OF MEBANE SO THAT ANY SERVICE INTERRUPTIONS ARE MINIMAL. 7. RELATION OF WATER MAINS TO SEWERS SHALL BE IN ACCORDANCE WITH CITY OF MEBANE STANDARDS AND STATE REGULATIONS. 8. ANY CONSTRUCTION WITHIN THE LOWES BLVD. PUBLIC R/W SHALL BE PER THE APPROVED PLANS AND NCDOT ENCROACHMENT AGREEMENT. 9. ANY LANE CLOSURES, BARRICADES, ETC, FOR THE NEW WATER / SEWER TAPS TO BE IN ACCORDANCE WITH NCMUTCD, NCDOT AND CITY OF MEBANE REQUIREMENTS. 10. DUE TO HIGH RESIDUAL PRESSURES ALL WATER SERVICE CONNECTIONS SHALL CONTAIN A PRESSURE REDUCING ASSEMBLY. 11. ALL WATER MAIN MATERIALS SHALL BE CLASS 50 DUCTILE IRON PIPE UNLESS NOTED OTHERWISE ON THE PLANS. 12. ALL SEWER MAIN MATERIAL SHALL BE SDR-35 PVC UNLESS NOTED OTHERWISE ON THE PLANS. 13. THE CONTRACTOR SHALL ENSURE THAT GATE VALVES/BOXES DO NOT FALL WITHIN CURB AND GUTTER OR ACCESSIBLE RAMPS 14. ALL UTILITIES AND SERVICES INCLUDING BUT NOT LIMITED TO GAS, WATER, ELECTRIC, SANITARY AND STORM SEWER, TELEPHONE, CABLE, FIBER OPTIC, ETC. WITHIN THE LIMITS OF DISTURBANCE SHALL BE VERTICALLY AND HORIZONTALLY LOCATED. THE CONTRACTOR SHALL USE AND COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE UTILITY NOTIFICATION SYSTEM TO LOCATE ALL THE UNDERGROUND UTILITIES. THE CONTRACTOR IS RESPONSIBLE FOR REPAIRS OF DAMAGE TO ANY EXISTING UTILITIES DURING CONSTRUCTION AT NO COST TO THE OWNER. 15. UTILITY COORDINATION SHALL BE INCLUDED IN THE PROJECT SCHEDULE AND IT IS THE EXPLICIT RESPONSIBILITY OF THE CONTRACTOR TO ASSURE THAT THE PROJECT SCHEDULE INCLUDES THE NECESSARY RELOCATIONS. THE CONTRACTOR WILL NOT BE PAID ADDITIONALLY FOR THIS COORDINATION. 16. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE LOCATIONS AND DEPTHS OF ALL EXISTING UNDERGROUND UTILITIES AND STRUCTURES BEFORE THE START OF WORK AND TO TAKE WHATEVER STEPS NECESSARY TO PROVIDE FOR THEIR PROTECTION. THE ENGINEER HAS DILIGENTLY ATTEMPTED TO LOCATE AND INDICATE ALL EXISTING FACILITIES ON THESE PLANS; HOWEVER, THIS INFORMATION IS SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS OF UTILITIES SHOWN OR NOT SHOWN. COMPLETENESS OR ACCURACY OF LOCATION AND DEPTH OF UNDERGROUND UTILITIES AND STRUCTURES IS NOT GUARANTEED. 17. THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES FOR EXACT LOCATION AND PROTECTION OF THEIR UTILITIES PRIOR TO STARTING CONSTRUCTION. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR AND REPLACE ANY AND ALL DAMAGE MADE TO UTILITIES BY THE CONTRACTOR. 18. CONTRACTOR MUST APPLY FOR ALL UTILITY CONNECTION APPLICATIONS. CONTRACTOR IS RESPONSIBLE FOR ALL UTILITY CONNECTION FEES FOR CONSTRUCTION. REFER TO COVER SHEET FOR AVAILABLE UTILITY COMPANY LIST. 19. CONTRACTOR MUST OBTAIN ANY REQUIRED UTILITY DETAILS FOR RECONNECTION OF EXISTING SERVICES OR NEW SERVICE AND IS RESPONSIBLE FOR THE CONSTRUCTION OF EACH NEW SERVICE PER THE APPROPRIATE UTILITY COMPANY'S SPECIFICATIONS. 20. IF CONFLICTS ARE FOUND, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND ENGINEER FOR INSTRUCTION BEFORE PROCEEDING WITH WORK. 21. ALL PIPE LENGTHS AND DISTANCES BETWEEN STRUCTURES ARE MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE ALONG A HORIZONTAL PLANE. 22. THE CONTRACTOR SHALL PROVIDE ANY AND ALL EXCAVATION AND MATERIAL SAMPLES NECESSARY TO CONDUCT REQUIRED SOIL TESTS. ALL ARRANGEMENTS AND SCHEDULING FOR THE TESTING SHALL BE THE CONTRACTOR'S RESPONSIBILITY. 23. SOILS TESTING AND ON -SITE INSPECTION SHALL BE PERFORMED BY AN INDEPENDENT GEOTECHNICAL ENGINEER. THE SOILS ENGINEER SHALL PROVIDE COPIES OF TEST REPORTS TO THE CONTRACTOR, THE OWNER AND THE OWNER'S REPRESENTATIVE AND SHALL PROMPTLY NOTIFY THE OWNER, HIS REPRESENTATIVE AND THE CONTRACTOR SHOULD WORK PERFORMED BY THE CONTRACTOR FAIL TO MEET THESE SPECIFICATIONS. 24. CONTRACTOR SHALL EXCAVATE ONLY ENOUGH TRENCH FOR WHICH PIPE CAN BE INSTALLED AND TRENCH BACKFILLED BY THE END OF EACH WORK DAY. 25. BEDDING REQUIREMENTS SPECIFIED HEREIN ARE TO BE CONSIDERED AS MINIMUMS FOR RELATIVELY DRY, STABLE EARTH CONDITIONS. ADDITIONAL BEDDING SHALL BE REQUIRED FOR ROCK TRENCHES AND WET AREAS. CONTRACTOR SHALL HAVE THE RESPONSIBILITY TO PROVIDE SUCH ADDITIONAL BEDDING AS MAY BE REQUIRED TO PROPERLY CONSTRUCT THE WORK. 26. COMPACTION OF THE BACKFILL OF ALL TRENCHES IN STRUCTURAL AREAS SHALL BE COMPACTED TO THE DENSITY OF 95% OF THEORETICAL MAXIMUM DRY DENSITY UP TO THE LAST 12" OF BACKFILL WHICH WILL BE COMPACTED TO 100% OF THE MAXIMUM DRY DENSITY (ASTM D698). BACKFILL MATERIAL SHALL BE FREE FROM ROOTS, STUMPS, OR OTHER FOREIGN DEBRIS AND SHALL BE PLACED IN LIFTS NOT TO EXCEED 8 INCHES IN COMPACTED FILL THICKNESS. A REPORT FROM A GEOTECHNICAL ENGINEER MAY BE REQUIRED BY THE PUBLIC WORKS INSPECTOR. CORRECTION OF ANY TRENCH SETTLEMENT WITHIN A YEAR FROM THE DATE OF APPROVAL WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 27. RUNOFF FROM IMPERVIOUS AREAS SHALL NOT BE DIRECTED INTO THE SANITARY SEWER NOR ONTO ADJACENT PROPERTIES. 28. ALL JOINTS ON THE STORM WATER CONVEYANCE SYSTEM SHALL BE WATERTIGHT. 29. ALL ELECTRICAL SERVICE LINES TO OR AROUND THE PROPOSED STRUCTURE SHALL BE UNDERGROUND. 30. CONTRACTOR SHALL SET ALL WATER GATE VALVE BOXES AND SANITARY SEWER MANHOLE RIM ELEVATIONS FLUSH WITH INITIAL PLACEMENT OF ASPHALT AND ADJUST TO FINAL ASPHALT ELEVATION JUST PRIOR TO THAT PLACEMENT. FULL DEPTH ASPHALT COLLARS SHALL BE PROVIDED AROUND EACH AS REQUIRED BY THE CITY OF MEBANE AFTER FINAL ADJUSTMENTS HAVE BEEN MADE AND PREVIOUS TO THE FINAL LIFT INSTALLED. SUP MODIFICATION NOTES: 1. ALL HOTEL AND SITE IDENTIFICATION SIGNS SHALL BE PERMITTED SEPARATELY THROUGH THE CITY OF MEBANE. 2. LIGHTED BUILDING MOUNTED SIGNS WILL BE PLACED NEAR THE TOP OF THE PHASE 1 HOTEL ON ALL FOUR SIDES. DETAILS FOR THIS SIGNS WILL BE PROVIDED WITH CONSTRUCTION DRAWINGS. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. WATER AND SEWER SERVICE NOTES: 1. HORIZONTAL AND VERTICAL SEPARATION 1.1 SANITARY SEWERS SHALL BE LAID AT LEAST 10-FEET HORIZONTALLY FROM ANY EXISTING OR PROPOSED WATER MAIN. THE DISTANCE SHALL BE MEASURED EDGE TO EDGE. IN CASES WHERE IT IS NOT PRACTICAL TO MAINTAIN A 10-FOOT SEPARATION, THE PUBLIC WORKS SUPPLY MAY ALLOW DEVIATION A CASE -BY -CASE BASIS, IF SUPPORTED BY DATA FROM THE DESIGN ENGINEER. SUCH DEVIATION ON MAY ALLOW THE INSTALLATION OF THE SANITARY SEWER CLOSER TO A WATER MAIN, PROVIDED THAT THE WATER MAIN IS IN A SEPARATE TRENCH OR ON AN UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE SANITARY SEWER AND AT AN ELEVATION SO THE BOTTOM OF THE WATER MAIN IS AT LEAST 18-INCHES ABOVE THE TOP OF THE SEWER. 1.2 IF IT IS IMPOSSIBLE TO OBTAIN PROPER HORIZONTAL AND VERTICAL SEPARATION AS DESCRIBED ABOVE OR ANYTIME THE SANITARY SEWER IS OVER THE WATER MAIN, BOTH THE WATER MAIN AND SANITARY SEWER MUST BE CONSTRUCTED OF FERROUS PIPE COMPLYING WITH THE PUBLIC WATER SUPPLY DESIGN STANDARDS AND BE PRESSURE TESTED TO 150PSI TO ASSURE WATER TIGHTNESS BEFORE BACKFILLING. 1.3 A 24-INCH VERTICAL SEPARATION SHALL BE PROVIDED BETWEEN STORM SEWER AND SANITARY SEWER LINES OR FERROUS PIPE SPECIFIED. A 12-INCH VERTICAL SEPARATION SHALL BE PROVIDED BETWEEN STORM SEWER AND WATER MAIN. 1.3.1 IF A 12-INCH VERTICAL SEPARATION IS NOT MAINTAINED AT A CROSSING BETWEEN STORM SEWER AND WATER MAINS (OR PRESSURE SEWERS). THE WATER MAIN SHALL BE CONSTRUCTED OF FERROUS PIPE AND A CONCRETE COLLAR SHALL BE POURED AROUND WATER MAINS AND STORM SEWER TO IMMOBILIZE THE CROSSING. 2. CROSSINGS 2.1 SANITARY SEWER CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18-INCHES BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF THE SANITARY SEWER. THE CROSSING SHALL BE ARRANGED SO THAT THE SANITARY SEWER JOINTS WILL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM THE WATER MAIN JOINTS. 2.2 WHEN IT IS IMPOSSIBLE TO OBTAIN PROPER HORIZONTAL AND VERTICAL SEPARATION AS STIPULATED ABOVE, ONE OF THE FOLLOWING METHODS MUST BE SPECIFIED. 2.2.1 THE SANITARY SEWER SHALL BE DESIGNED AND CONSTRUCTED OF FERROUS PIPE AND SHALL BE PRESSURE TESTED AT 150-PSI TO ASSURE WATER TIGHTNESS PRIOR TO BACKFILLING, OR 2.2.2 EITHER THE WATER MAIN OR THE SANITARY SEWER LINE MAY BE ENCASED IN A WATERTIGHT CARRIER PIPE, WHICH EXTENDS 10-FEET ON BOTH SIDES OF THE CROSSING, MEASURED PERPENDICULAR TO THE WATER MAIN. THE CARRIER PIPE SHALL BE OF MATERIALS APPROVED BY THE PUBLIC WATER SUPPLY FOR USE IN WATER MAIN CONSTRUCTION. FIRE DEPARTMENT NOTES: 1. FIRE APPARATUS ACCESS ROADS; ANY FIRE APPARATUS ACCESS ROADS, ANY PUBLIC/PRIVATE STREET, PARKING LOT ACCESS, FIRE LANES AND ACCESS ROADWAYS, USED FOR FIRE DEPARTMENT ACCESS SHALL BE ALL WEATHER AND DESIGNED TO CARRY THE IMPOSED LOAD OF FIRE APPARATUS WEIGHING AT LEAST 80,000 LBS. FIRE APPARATUS ACCESS ROADS SHALL HAVE A MINIMUM WIDTH OF 20' EXCLUSIVE OF SHOULDERS WITH AN OVERHEAD CLEARANCE OF AT LEAST 13'-6" FOR STRUCTURES NOT EXCEEDING 30' IN HEIGHT AND SHALL PROVIDE ACCESS TO WITHIN 150' OF ALL EXTERIOR PORTIONS OF THE BUILDING. STRUCTURES EXCEEDING 30' IN HEIGHT SHALL BE PROVIDED WITH AN AERIAL APPARATUS ACCESS ROAD 26' IN WIDTH IN THE IMMEDIATE VICINITY OF THE BUILDING OR PORTION THEREOF AND SHALL PROVIDE AT LEAST ONE OF THE REQUIRED ACCESS ROADS TO BE LOCATED NOT LESS THAN 15' AND NOT MORE THAN 30' FROM THE STRUCTURE PARALLEL TO ONE ENTIRE SIDE OF THE STRUCTURE. NC FPC 2018 502.1,503.1.1, 503.2.1, D102.1 2. GRADE AND APPROACH; FIRE APPARATUS ACCESS ROADS SHALL NOT EXCEED 10% IN GRADE UNLESS APPROVED BY THE FIRE CHIEF AND ALL APPROACH AND DEPARTURE ANGLES SHALL BE WITHIN THE LIMITS ESTABLISHED BASED ON THE DEPARTMENTS APPARATUS. NC FPC 2018, 503.2.7, 503.2.8 and D103.2 3. GATES AND BARRICADES; WHERE REQUIRED OR AUTHORIZED BY THE FIRE CODE OFFICIAL AND PERMANENT OR TEMPORARY CONSTRUCTION, ANY GATES ACROSS FIRE APPARATUS ACCESS ROADS SHALL BE A MINIMUM WIDTH OF 20 FEET, BE OF SWINGING OR SLIDING TYPE, HAVE AN EMERGENCY MEANS OF OPERATION, SHALL BE OPENABLE BY EITHER FORCIBLE ENTRY OR KEYED, CAPABLE OF BEING OPERATED BY ONE PERSON, AND SHALL BE INSTALLED AND MAINTAINED ACCORDING TO UL 325 and ASTM F 2200. NC FPC 2018, 503.5, 503.6, D103.5 4. FIRE LANES; WHERE REQUIRED, APPROVED MARKING SIGNS INCLUDING THE WORDS, NO PARKING -FIRE LANE SIGNS SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS. NC FPC 2018, 503.3, D103.6, D103.6.1, D103.6.2 5. PREMISE IDENTIFICATION; APPROVED BUILDING ADDRESS NUMBERS, PLACED IN ACCEPTABLE POSITION TO THE FIRE CODE OFFICIAL, SHALL BE REQUIRED ON ALL NEW BUILDINGS. NC FPC 2018, 505.1 6. KEY BOXES; WHERE REQUIRED BY THE FIRE CODE OFFICIAL, A SECURE KEY BOX, MOUNTED ON THE ADDRESS SIDE OF THE BUILDING, NEAR THE MAIN ENTRANCE, SHALL BE PROVIDED TO ENSURE ADEQUATE ACCESS TO THE BUILDING BASED ON LIFE SAFETY AND/OR FIRE PROTECTION NEEDS. NC FPC 2018, 506 7. FIRE HYDRANTS; THE ADDITION OF ANY REQUIRED HYDRANTS TO SERVE THE SUBMITTED BUILDING MUST FLOW A MINIMUM OF 2500 GPM PER TOWN ENGINEERING STANDARDS UNLESS APPROVED BY THE FIRE CODE OFFICIAL. THE FARTHEST HYDRANT SERVING A PROPOSED STRUCTURE MUST BE NO MORE THAN 500 FEET DISTANT. A MAXIMUM DISTANCE OF 500 FEET SPACING BETWEEN HYDRANTS MUST BE MAINTAINED UNLESS OTHERWISE APPROVED BY THE FIRE CODE OFFICIAL. LESSER SPACING DISTANCES MAY BE REQUIRED. A MINIMUM WORKING SPACE OF 3 FEET MUST BE MAINTAINED AROUND ALL HYDRANTS. WHERE HYDRANTS ARE SUBJECT TO PHYSICAL IMPACT, PHYSICAL PROTECTION MAY BE REQUIRED, NC FPC 2018, 507.5.6. THE MINIMUM NUMBER OF REQUIRED HYDRANTS AND THEIR SPACING MUST MEET NC FPC 2018, APPENDIX C, TABLE C 105.1 8. FIRE DEPARTMENT CONNECTIONS, LOCATIONS; ANY REQUIRED FDCS FOR ANY BUILDINGS SHALL MEET THE DESIGN AND INSTALLATION REQUIREMENTS FOR THE CURRENT, APPROVED EDITION OF NFPA 13, 13D, 13R, OR 14 OF THE NC FPC 2018 AND TOWN ORDINANCES; 7-38 FOR LOCATION. FDCS SHALL BE INSTALLED ON THE STREET/ADDRESS SIDE OF THE BUILDING AND WITHIN 100' OF A HYDRANT OR UNLESS OTHERWISE APPROVED BY THE FIRE CODE OFFICIAL AND SHALL NOT BE OBSTRUCTED OR HINDERED BY PARKING OR LANDSCAPING. FDC'S SHALL BE EQUIPPED WITH NST. 9. FIRE DEPARTMENT CONNECTIONS, INSTALLATION; A WORKING SPACE OF NOT LESS THAN 36 INCHES IN WIDTH AND DEPTH AND A WORKING SPACE OF 78 INCHES IN HEIGHT SHALL BE PROVIDED ON ALL SIDES WITH THE EXCEPTION OF WALL MOUNTED FDC'S UNLESS OTHERWISE APPROVED BY THE FIRE CODE OFFICIAL. THE FDC'S WHERE REQUIRED MUST BE PHYSICALLY PROTECTED BY AN APPROVED BARRIER FROM IMPACTS. NC FPC 2018, 912.1, 912.2 912.2.1, 912.3.2, 312 PROJECT NOTES: 1. TWO ENTRANCE FEATURES SHALL BE PROVIDED AT THE ENTRANCE INTO THE SITE. ONE BEING A SITE IDENTIFICATION SIGN. 2. CONSTRUCTION ON THIS PROJECT SHALL BE IN ACCORDANCE WITH THE CITY OF MEBANE , STATE, NCDOT, AND UTILITY PROVIDER STANDARDS, CODE OF ORDINANCES, BUILDING CODES, STANDARD DETAILS AND SPECIFICATIONS. 3. ALL SITE WORK, AT A MINIMUM, SHALL BE PERFORMED IN ACCORDANCE WITH THE 2018 NCDOT ROADWAY STANDARD DRAWINGS AND STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES UNLESS OTHERWISE NOTED OR DIRECTED. 4. UNDERGROUND UTILITIES MAY EXIST ON, ALONG OR WITHIN CONFLICT OF THIS PROJECT. THE CONTRACTOR SHALL FIELD VERIFY VERTICAL AND HORIZONTAL LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR CONTACTING NC-811 OR THE APPROPRIATE UTILITY COMPANIES PRIOR TO ANY EXCAVATION. 5. CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO VERIFY LOCATION OF AND PREVENT DISTURBANCE TO EXISTING UTILITIES IN WORK AREA. 6. THE CONTRACTOR SHALL OBSERVE ALL REQUIRED SAFETY PRECAUTIONS IN THE PERFORMANCE OF ALL WORK IN ACCORDANCE WITH OSHA. 7. THE CONTRACTOR SHALL GRADE, SEED AND SOD OR OTHERWISE PROVIDE TEMPORARY AND PERMANENT STABILIZATION OF ALL DISTURBED AREAS, ESPECIALLY SLOPES. SEE EROSION CONTROL INSTRUCTIONS, IF APPLICABLE. 8. ANY SUBSTITUTIONS, CHANGES, OR MODIFICATIONS SHALL BE APPROVED BY THE PROJECT ENGINEER, PLANNING DEPARTMENT STAFF, AND DEVELOPER PRIOR TO INSTALLATION/CONSTRUCTION OF CORRESPONDING ITEMS. 9. THE GRADE LINES DENOTE THE FINISHED ELEVATIONS OF THE PROPOSED SURFACE. GRADE LINES MAY BE ADJUSTED AT THEIR BEGINNING, ENDING AND AT STRUCTURES AS DIRECTED BY THE ENGINEER IN ORDER TO PROVIDE A PROPER TIE-IN. CONTRACTOR SHALL FIELD VERIFY ALL PROPOSED INVERTS & FINISHED SURFACES TO ENSURE THAT MINIMUM SLOPE & COVER REQUIREMENTS ARE PROVIDED PRIOR TO INSTALLATION OF REFERENCED ITEMS. 10. PRIOR TO BEGINNING CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ACQUIRING ALL PERMITS NECESSARY FOR CONSTRUCTION. THE CONTRACTOR SHALL READ ALL PERMITS AND ENSURE THAT CONSTRUCTION COMPLIES WITH THE PERMITS. REQUIRED PERMITS AND REVIEWS MAY INCLUDE, BUT ARE NOT LIMITED TO: CITY/COUNTY APPROVALS/PERMITS, CITY FIRE DEPARTMENT, SOLID WASTE REVIEWS, NCDOT PERMITS, DRIVEWAY PERMITS, RIGHT OF WAY ENCROACHMENT AGREEMENTS, SOIL AND EROSION CONTROL PERMITS, NCDENR PERMITS, WATER PERMITS, SEWER PERMITS, ENVIRONMENTAL PERMITS, WETLAND DISTURBANCE PERMITS, STREAM CROSSING PERMITS, POWER EASEMENT ENCROACHMENT AGREEMENTS, USACE/DWQ PERMITS, STORMWATER PERMITS, ZONING APPROVAL, AND BUILDING CODE APPROVALS/PERMITS. IF THE CONTRACTOR HAS QUESTIONS ABOUT PERMIT LANGUAGE, OR THE NEED FOR A PERMIT, HE MUST CONTACT THE DEVELOPER AND THE ENGINEER PRIOR TO BEGINNING CONSTRUCTION. 11. THE EXISTING WETLAND LOCATIONS WERE DETERMINED BY: PERMITTING AND MITIGATION MUST BE PROVIDED PRIOR TO THE START OF CONSTRUCTION. GRADING AND STORM DRAINAGE NOTES: 1. ANY WALLS EXCEEDING 4' IN HEIGHT SHALL BE DESIGNED AND CERTIFIED BY A PROFESSIONAL ENGINEER. CONTRACTOR SHALL OBTAIN ANY REQUIRED WALL PERMITS THROUGH THE BUILDING INSPECTIONS DEPARTMENT. 2. THIS PROPERTY IS WITHIN THE HAW CREEK UNPROTECTED WATERSHED IN THE CAPE FEAR RIVER BASIN. 3. ALL PIPE TO BE INSTALLED ON -SITE AND IN THE RIGHT OF WAY SHALL MEET OR EXCEED THE DOT ASTM AND AASHTO SPECIFICATION REQUIREMENTS FOR SUCH PIPE MATERIAL. CONTRACTOR SHALL VERIFY APPROVAL WITH DOT FOR ALL PIPE MATERIALS TO BE USED IN THEIR RIGHT OF WAY. 4. ALL WORK WITHIN DOT ROW SHALL COMPLY WITH LATEST 2018 NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, NCDOT STANDARD DRAWINGS, AND THE MUTCD STANDARDS. 5. ALL ON -SITE PIPE SHALL BE INSTALLED MEETING COVER, BACKFILL AND BEDDING REQUIREMENTS PER THE MANUFACTURER'S RECOMMENDATIONS. 6. NCDOT PRE -CAST DRAINAGE STRUCTURES / MANHOLES CAN BE USED IN LIEU OF NCDOT STANDARD BRICK OR CONCRETE CATCH BASINS. ANY DEVIATION FROM THE SPECIFIED STRUCTURES SHALL BE APPROVED BY ENGINEER PRIOR TO INSTALLATION AND SHALL MAINTAIN COMPLIANCE WITH ALL CORRESPONDING DOT MATERIAL, DRAWING & DETAILED SPECIFICATIONS. NO WAFFLE BOXES SHALL BE USED. 7. CONTRACTOR SHALL FIELD VERIFY THAT PROPOSED GRADES MATCH EXISTING PAVEMENT AT ALL CONNECTION/TIE POINTS PRIOR TO FINAL LIFT OF ASPHALT. CONTRACTOR SHALL NOTIFY ENGINEER IF DISCREPANCY OCCURS. 8. PROPOSED CONTOUR LINES REPRESENT FINISHED GRADE ELEVATIONS. CONTOUR LINES MAY BE ADJUSTED AT THEIR BEGINNING, ENDING AND AT STRUCTURES AS DIRECTED BY THE ENGINEER IN ORDER TO PROVIDE A PROPER TIE-IN. 9. CONTRACTOR SHALL FIELD VERIFY TIE OUTS POINTS AND INVERTS PRIOR TO CONSTRUCTION TO AVOID CONFLICTS. CONTACT ENGINEER IF DISCREPANCIES ARE FOUND. ANY PROPOSED GRADE SPOT ELEVATIONS,PROPOSED INVERTS,FFE'S,ETC PROVIDED SHALL OVERRULE CONTOUR LINES. 10. A SEDIMENTATION AND EROSION CONTROL PLAN SHALL BE APPROVED BY NCDEQ PRIOR TO CONSTRUCTION. 11. EROSION CONTROL INSPECTOR OR CITY/TOWN PLANNING DEPARTMENT STAFF SHALL BE CONTACTED TO INSPECT TREE PROTECTION FENCING BEFORE GRADING WORK BEGINS. 12. THE CITY OF MEBANE MUST APPROVE THE STORMWATER MANAGEMENT PLAN FOR THIS PROJECT PRIOR TO BEGINNING CONSTRUCTION. 13. CONTRACTOR SHALL MONITOR, MAINTAIN, MOVE AND/OR ADD SILT FENCE, SILT FENCE OUTLETS, AND J-HOOKS AS NEEDED BASED ON FIELD AND RUN-OFF CONDITIONS AND AS DIRECTED BY THE ENGINEER AND/OR E.C. REPRESENTATIVE. 14. IF AN OFFSITE SOIL SPOIL OR BORROW SITE IS UTILIZED, THEN THE DISTURBED AREA FOR THE SPOIL/BORROW SITE MUST BE INCLUDED IN THE LAND -DISTURBANCE PLAN AND PERMIT UNLESS THE SPOIL/BORROW SITE ALREADY HAS A LAND -DISTURBING PERMIT. 15. SEE SIA FOR DETAILED NUTRIENT AND PEAK FLOW CALCULATIONS. 16. ALL REQUIRED STORM DRAINAGE AND BMP EASEMENTS TO BE PLATTED UPON FINAL CONSTRUCTION OF NEW CONVEYANCES. 17. ALL UTILITY TRENCHING, BACKFILL, FOOTER AND BUILDING PAD PREPARATIONS, AND SUB -GRADE COMPACTION EFFORTS SHALL MEET/EXCEED GEOTECHNICAL RECOMMENDATIONS. ADDITIONAL SPECIFICATIONS AND REQUIREMENTS FOR BUILDING PAD PREPARATION AND COMPACTION MAY EXIST IN ARCHITECTURAL AND STRUCTURAL DRAWINGS AND SHALL BE EXECUTED/IMPLEMENTED AS REQUIRED. 18. ALL 2:1 SLOPES ON SITE SHALL BE MATTED AND PREPARED TO ENSURE VEGETATIVE COVER. ALL GRASS SLOPES WHICH EXCEED 3:1 (H:V) SHALL UTILIZE NORTH AMERICAN GREEN (NAG) CONSTRUCTION PRODUCTS TURF REINFORCEMENT MATS SC150 OR APPROVED EQUAL, UNLESS OTHERWISE SPECIFIED ON PLANS. MATS SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS AND STANDARDS. CONTRACTOR SHALL COORDINATE INSTALLATION INSPECTION WITH MANUFACTURER. 19. ALL STORM DRAINAGE EASEMENTS ARE PRIVATE. 20. STORMWATER RUN-OFF FROM ALL BUILT UPON AREAS RELATED TO PUBLIC ROADWAYS, RESIDENTIAL DRIVEWAYS, AND UNITS SHALL BE TREATED AT STORMWATER BMP's. SEE GRADING AND STORM DRAINAGE PLAN FOR STORM STRUCTURE INFORMATION. 21. SEE SCM DETAIL SHEETS FOR ADDITIONAL GRADING AND STORM STRUCTURE INFORMATION. 22. CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING ALL PAVED AREAS AND CURB PROVIDE POSITIVE DRAINAGE TO A DRAINAGE STRUCTURE AND NO BIRD BATHS' ARE PRESENT IN THE FINAL PRODUCT ADA INSTRUCTIONS TO CONTRACTOR: 1. CONTRACTORS MUST EXERCISE APPROPRIATE CARE AND PRECISION IN CONSTRUCTION OF ADA ACCESSIBLE COMPONENTS AND ACCESS ROUTES FOR THE SITE. THESE COMPONENTS, AS CONSTRUCTED, MUST COMPLY WITH THE CURRENT ADA STANDARD SAND REGULATIONS BARRIER FREE ACCESS AND ANY MODIFICATIONS, REVISIONS OR UPDATES TO SAME. FINISHED SURFACES ALONG THE ACCESSIBLE ROUTE OF TRAVEL FROM PARKING SPACE(S), PUBLIC TRANSPORTATION, PEDESTRIAN ACCESS, INTER -BUILDING ACCESS, TO POINTS OF ACCESSIBLE BUILDING ENTRANCE/EXIT, MUST COMPLY WITH THESE ADA CODE REQUIREMENTS. THESE INCLUDE, BUT ARE NOT LIMITED TO THE FOLLOWING: 2. PARKING SPACES AND PARKING AISLES - SLOPE SHALL NOT EXCEED 1:50 (1/4" PER FOOT OR NOMINALLY 2.0%) IN ANY DIRECTION. 3. CURB RAMPS - SLOPE MUST NOT EXCEED 1:12 (8.3%) FOR A MAXIMUM OF SIX (6) FEET. 4. LANDINGS - MUST BE PROVIDED AT EACH END OF RAMPS, MUST PROVIDE POSITIVE DRAINAGE, AND MUST NOT EXCEED 1:50 (1/4" PER FOOT OR NOMINALLY 2.0%) IN ANY DIRECTION. 5. PATH OF TRAVEL ALONG ACCESSIBLE ROUTE - MUST PROVIDE A 36-INCH OR GREATER UNOBSTRUCTED WIDTH OF TRAVEL (CAR OVERHANGS AND/OR HANDRAILS CANNOT REDUCE THIS MINIMUM WIDTH). THE SLOPE MUST BE NO GREATER THAN 1:20 (5.0%) IN THE DIRECTION OF TRAVEL, AND MUST NOT EXCEED 1:50 (1/4" PER FOOT OR NOMINALLY 2.0%) IN CROSS SLOPE. WHERE PATH OF TRAVEL WILL BE GREATER THAN 1:20 (5.0%), ADA RAMP REGULATIONS MUST BE ADHERED TO. A MAXIMUM SLOPE OF 1:12 (8.3%), FOR A MAXIMUM RISE OF 2.5 FEET, MUST BE PROVIDED. THE RAMP MUST HAVE ADA HAND RAILS AND "LEVEL" LANDINGS ON EACH END THAT ARE CROSS SLOPED NO MORE THAN 1:50 IN ANY DIRECTION (1/4" PER FOOT OR NOMINALLY 2.0%) FOR POSITIVE DRAINAGE. 6. DOORWAYS - MUST HAVE A "LEVEL" LANDING AREA ON THE EXTERIOR SIDE OF THE DOOR THAT IS SLOPED AWAY FROM THE DOOR NO MORE THAN 1:50 (1/4" PER FOOT OR NOMINALLY 2.0%) FOR POSITIVE DRAINAGE. THIS LANDING AREA MUST BE NO LESS THAN 60 INCHES (5 FEET) LONG, EXCEPT WHERE OTHERWISE PERMITTED BY ADA STANDARDS FOR ALTERNATIVE DOORWAY OPENING CONDITIONS. (SEE ICC/ANSI A117.1-2003 AND OTHER REFERENCED INCORPORATED BY COD.) 7. WHEN THE PROPOSED CONSTRUCTION INVOLVES RECONSTRUCTION, MODIFICATION, REVISION OR EXTENSION OF OR TO ADA COMPONENTS FROM EXISTING DOORWAYS OR SURFACES, CONTRACTOR MUST VERIFY EXISTING ELEVATIONS SHOWN ON THE PLAN. NOTE THAT TABLE 405.2 OF THE DEPARTMENT OF JUSTICES ADA STANDARDS FOR ACCESSIBLE DESIGN ALLOWS FOR STEEPER RAMP SLOPES, IN RARE CIRCUMSTANCES. PRIOR TO THE COMMENCEMENT OF WORK, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE DESIGN ENGINEER IN WRITING OF ANY DISCREPANCIES AND/OR FIELD CONDITIONS THAT DIFFER IN ANY WAY OR ANY RESPECT FROM WHAT IS SHOWN ON THE PLANS, IN WRITING, BEFORE COMMENCEMENT OF WORK. CONSTRUCTED IMPROVEMENTS MUST FALL WITHIN THE MAXIMUM AND MINIMUM LIMITATIONS IMPOSED BY THE BARRIER FREE REGULATIONS AND THE ADA REQUIREMENTS. 8. THE CONTRACTOR MUST VERIFY THE SLOPES OF CONTRACTOR'S FORMS PRIOR TO POURING CONCRETE. IF ANY NON-CONFORMANCE IS OBSERVED OR EXISTS, CONTRACTOR MUST IMMEDIATELY NOTIFY THE ENGINEER PRIOR TO POURING CONCRETE. CONTRACTOR IS RESPONSIBLE FOR ALL COSTS TO REMOVE, REPAIR AND REPLACE NON -CONFORMING CONCRETE. 9. THE SITE SHALL BE FULLY COMPLIANT WITH THE NORTH CAROLINA ACCESSIBILITY CODES (ANSI 117.1 -2009 AND CHAPTER 11 OF THE NCBC) UNLESS AND EXCEPT IN AREAS WHERE AN APPROVED STATEMENT FROM A SITE ENGINEER, SURVEYOR OR ARCHITECT VERIFIES THAT SITE CONDITIONS EXIST WHERE THE TOPOGRAPHY OF THE SITE IS EXTREME AND ONLY ALTERNATE METHODS OF COMPLIANCE ARE POSSIBLE. 10.ACCESSIBILITY REQUIREMENTS: THAT PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY, THE APPLICANT SHALL PROVIDE THE MINIMUM REQUIRED ACCESSIBLE PARKING SPACES AND DESIGN ALL ACCESSIBLE PARKING SPACES, RAMPS, AND CROSSWALKS, AND ASSOCIATED INFRASTRUCTURE ACCORDING TO AMERICANS WITH DISABILITIES ACT STANDARDS, NORTH CAROLINA BUILDING CODE, AMERICAN NATIONAL STANDARDS INSTITUTE ANSI CODE, AND TOWN STANDARD.. PARKING - NUMBER OF SPACES TO COMPLY WITH NCBC 2012 SECTION 1106.1, 1 PER 6 COMPLIANT SPACES OR PORTION THEREOF MUST BE VAN ACCESSIBLE, NO SLOPE TO EXCEED 2 PERCENT IN ANY DIRECTION. SIGNAGE PER NC EQUIREMENTS, MUT-CD AND ICC A 117.1.2. CURB CUTS AND ACCESSIBLE ROUTES PER ICC A117.1 2009 ED. CROSS SLOPE LIMITED TO 2 PERCENT, CALL FOR INSPECTION BEFORE PLACEMENT OF CONCRETE. A SLOPE GREATER THAN 5 PERCENT REQUIRES CONSTRUCTION AS A RAMP. IT IS STRONGLY RECOMMENDED THAT THE CONTRACTOR REVIEW THE INTENDED CONSTRUCTION WITH THELOCAL BUILDING CODE PRIOR TO COMMENCEMENT OF CONSTRUCTION. MEBANE GENERAL NOTES: 1. ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT PLANS AND/OR SPECIFICATIONS, CITY OF MEBANE STANDARD DETAILS AND CONSTRUCTION STANDARDS, STATE CONSTRUCTION STANDARDS, OSHA REGULATIONS AND OTHER APPLICABLE CONTRACT DOCUMENTS. 2. A COPY OF THE CONSTRUCTION DRAWINGS BEARING THE APPROVAL STAMP FROM THE CITY OF MEBANE SHALL ALWAYS BE ON SITE AND AVAILABLE. 3. MATERIAL SUBMITTALS TO BE APPROVED BY THE CITY OF MEBANE PRIOR TO ORDERING MATERIAL. 4. MODIFICATION TO THE APPROVED DRAWINGS SHALL NOT BE MADE WITHOUT THE WRITTEN APPROVAL OF THE DESIGN ENGINEER AND THE CITY OF MEBANE. 5. PRIOR TO CONSTRUCTION, ALL NECESSARY PERMITS TO COMPLETE THE CONSTRUCTION SHOULD BE ACQUIRED AND FOLLOWED. 6. PRIOR TO STARTING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL HOLD A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF MEBANE, OWNER/REP, PLANNING, EROSION CONTROL, GEOTECHNICAL ENGINEER, ALL SUB -CONTRACTORS, AND ENGINEER/REP. 7. GEOTECHNICAL SPREADSHEET TO BE PROVIDED TO THE CITY PRIOR TO PRE -CONSTRUCTION MEETING FOR REVIEW. SPREADSHEET TO ACCOMPANY GEOTECHNICAL REPORTS. 8. ALL SOIL WITHIN THE RIGHT OF WAY AND PUBLIC EASEMENTS SHALL BE COMPACTED TO CITY OF MEBANE SPECIFICATIONS. CITY REPRESENTATIVE TO BE NOTIFIED 24 HOURS IN ADVANCE AND GIVEN THE OPPORTUNITY TO BE PRESENT DURING GEOTECH TESTING. 9. ALL UTILITY SEPARATIONS SHALL MEET THE REQUIREMENTS AS STATED IN THE CITY OF MEBANE CONSTRUCTION DOCUMENTS CHECKLIST. ALL UTILITY SEPARATIONS TO BE FIELD VERIFIED DURING INSTALLATION AND AS -INSTALLED SEPARATION LABELED ON AS -BUILT DRAWINGS. CONTRACTOR SHALL PROVIDE DESIGN ENGINEER VERIFICATION OF AS -INSTALLED SEPARATIONS TO BE INCLUDED ON AS -BUILT DRAWINGS SUBMITTED TO STATE. 10. ALL WATER MAIN TO INCLUDE TWO FORMS OF RESTRAINT (MEGA -LUGS AND BLOCKING) AND CONFORM TO THE DISTANCES STATED IN DETAIL W-26. 11. TESTING PROCEDURES PER CITY OF MEBANE STANDARDS AS FOLLOWS: WATER LINE -- PRESSURE TEST, CHLORINATE, BAC-T. SANITARY SEWER -- PRESSURE TEST, VACUUM TEST MANHOLES, MANDREL, VIDEO. STORM SEWER -- VIDEO. CONCRETE -- CYLINDERS EVERY 30 YARDS. ROADWAY -- DENSITY AND PROOF ROLL. ASPHALT -- CORES FOR BINDER, NUCLEAR DENSITY GAUGE TESTS ON FINAL LIFT. 12. FOR ALL PROJECTS WHERE THE FINAL LIFT OF ASPHALT IS NOT ANTICIPATED PRIOR TO THE ONSET OF WINTER, ALL MANHOLES AND VALVE BOXES ARE TO BE ADJUSTED FLUSH WITH THE BINDER COURSE. THE FINAL ADJUSTMENT TO FINISH GRADE WILL NOT BE DONE UNTIL IMMEDIATELY PRIOR TO THE PLACEMENT OF THE FINAL LIFT OF SURFACE COURSE. 13. CLASS III RCP SHALL HAVE A MINIMUM OF 3' OF COVER WITHIN THE ROW PER NCDOT REQUIREMENTS, WHERE 3 OF COVER IS NOT PROVIDED, CLASS IV RCP SHALL BE USED. 14. ALL DRAINAGE SWALES SHALL HAVE A MINIMUM OF 1% SLOPE. 15. ALL THIRD -PARTY UTILITIES TO ACQUIRE AN ENCROACHMENT AGREEMENT WITH THE CITY OF MEBANE PRIOR TO STARTING INSTALLATION. 16. BORROW PIT LOCATIONS TO BE SURVEYED FOR IN FIELD VERIFICATION AND BE IDENTIFIED ON THE PLAT. 17. UNDER ABSOLUTELY NO CIRCUMSTANCES SHALL ANY UNMANNED EXCAVATION BE LEFT OPEN OR UNPROTECTED DURING NON- WORKING HOURS. UTILIZE SIGNS, BARRICADES, ETC. TO ENSURE THE SAFETY OF THE GENERAL PUBLIC. 18. WHEN STAKING WATER LINE, CURB RADIUS POINTS SHOULD ALSO BE STAKED TO ENSURE VALVES ARE PLACED OUTSIDE OF CURB LINE AND HANDICAP RAMP TRUNCATED DOMES. 19. CONTRACTOR RESPONSIBLE FOR NOTIFYING THE CITY OF MEBANE AND THE DESIGN ENGINEER PRIOR TO TESTING WATER AND SEWER LINES TO COORDINATE SCHEDULING SINCE DESIGN ENGINEER WILL BE CERTIFYING AND MAY WANT TO WITNESS TESTING. 20. CONTRACTOR TO SCHEDULE PUNCH LIST WALK THROUGH AFTER BINDER LIFT OF ASPHALT HAS BEEN INSTALLED. DAM ENBANKMENT NOTES: 1. CONTROLLED FILL, AS SPECIFIED BY THE GEOTECHNICAL ENGINEER, IN THE DAM EMBANKMENT SHALL BE PLACED IN 6-INCH LOOSE LAYERS AND SHALL BE COMPACTED TO A DENSITY OF NO LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE CONTENT OF + OR - TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D698. MATERIAL SHALL BE HIGHLY IMPERMEABLE. 2. SOIL MATERIALS USED FOR EARTH FILL WHICH ARE CONSIDERED PERMEABLE OR WHICH EXHIBIT SIGNIFICANT SHRINK SWELL, SHALL NOT BE USED IN THE EMBANKMENT UNLESS A SPECIFIC DETAILED DESIGN REPORT FROM A GEOTECHNICAL ENGINEER IS SUBMITTED AND ACCEPTEDBY THE ENGINEER OF RECORD. 3. ALL VISIBLE ORGANIC DEBRIS SUCH AS ROOTS AND LIMBS SHALL BE REMOVED FROM THE FILL MATERIAL PRIOR TO COMPACTION TO THE REQUIRED DENSITY. SOILS WITH ORGANIC MATTER CONTENT EXCEEDING 5% BY WEIGHT SHALL NOT BE USED. STONES GREATER THAN 3-INCH (IN ANY DIRECTION) SHALL BE REMOVED FROM THE FILL PRIOR TO COMPACTION. 4. FILL MATERIAL PLACED AT DENSITIES LOWER THAN SPECIFIED MINIMUM DENSITIES OR AT MOISTURE CONTENTS OUTSIDE THE SPECIFIED RANGES OR OTHERWISE NOT CONFORMING TO SPECIFIED REQUIREMENTS SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE MATERIALS. 5. ANY FILL LAYER THAT IS SMOOTH DRUM ROLLED TO REDUCE MOISTURE PENETRATION DURING A STORM EVENT SHALL BE PROPERLY SCARIFIED PRIOR TO THE PLACEMENT OF THE NEXT SOIL LIFT. 6. SURFACE WATER SHALL BE CONTINUOUSLY CONTROLLED THROUGHOUT CONSTRUCTION AND THE PLACEMENT OF CONTROLLED FILL. 7. FOUNDATION AREAS MAY REQUIRE UNDERCUTTING OF COMPRESSIBLE AND/OR UNSUITABLE SOILS IN ADDITION TO THAT INDICATED ON THE ALL SUCH UNDERCUTTING SHALL BE PERFORMED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER AND SHALL BE MONITORED AND DOCUMENTED. IN NO CASE SHALL THERE BE AN ATTEMPT TO STABILIZE ANY PORTIONS OF THE FOUNDATION SOILS WITH CRUSHED STONE. 8. A CUTOFF TRENCH (KEY TRENCH) OF A MINIMUM WIDTH OF FIVE (5) FEET, ENTERED ON THE CENTERLINE OF THE DAM, SHALL BE INCORPORATED. THE CUTOFF TRENCH SHALL EXTEND TO A MINIMUM DEPTH OF TWO (2) FEET; HOWEVER, IN ALL CASES IT SHALL EXTEND INTO SOILS SUITABLE FOR THE EMBANKMENT FOUNDATION. 9. TREATMENT OF SEEPAGE AREAS, SUBGRADE PREPARATION, FOUNDATION DEWATERING AND ROCK FOUNDATION PREPARATION (I.E., TREATMENT WITH SLUSH GROUTING, DENTAL CONCRETE, ETC.) MAY BE REQUIRED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER. ALL SUCH ACTIVITIES SHALL BE CLOSELY MONITORED AND DOCUMENTED BY THE GEOTECHNICAL ENGINEER. 10. FILL ADJACENT TO THE RISER AND PIPE SHALL BE PLACED SO THAT LIFTS ARE AT THE SAME LEVEL ON BOTH SIDES OF THE STRUCTURES. 11. EARTHWORK COMPACTION WITHIN 3-FEET OF ANY STRUCTURES SHALL BE ACCOMPLISHED BY MEANS OF HAND TAMPERS, MANUALLY DIRECTED POWER TAMPERS OR PLATE COMPACTORS OR MINIATURE SELF-PROPELLED ROLLERS. 12. COMPACTION BY MEANS OF DROP WEIGHTS FROM A CRANE OR HOIST SHALL NOT BE PERMITTED. 13. HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO PASS OVER CAST -IN -PLACE STRUCTURES (INCLUDING THE CRADLE) UNTIL ADEQUATE CURING TIME HAS ELAPSED. 14. TO RE-ESTABLISH VEGETATION AFTER CONSTRUCTION, A 2- TO 3-INCH LAYER OF TOPSOIL SHALL BE PLACED ON THE DISTURBED EMBANKMENT SURFACE AND THE AREA SODDED AND MULCHED. l GS BY) N N N DATE CITY OF MEBANE COMMENTS L. REVISIONS f` CDLn M CV N- G SERVICES z DRAWING ALTERATION 1- U w (79 - x U w w z z w 1- U w O TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER DESIGN AND ENGINEERING SERVICES State License #: P-0339 J >- m z cc GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE u- 320 Executive Court 00 N t\ U z 0 0 x Fax: (919) 732-6676 0 X x J 7- w 0 CI J NQN w w CD PROJECT NO. 18-0156 DRAWING NAME: 18-0156_CS.dwg SHEET NO. J C-4 vil\Current Drawings \18-0156 S.dwg, C-5 SITE & UTILITY PLAN, 5/23/2022 4:58:53 PM, govinda.sed N:\2018\18-0156.010 - DRPB Hospitality LLC - Mebane Ho FD 4� & $5 C A�� ��"�g`\G R\G'N �v�\PB�Ew\DEN l S74 5�,49„W � 146.52 GPIN 9804922987 PARCEL ID 170381 TOLLINGWOOD -HAWFIELDS LLC DB: 2835/293 PB: 73/102 VACANT COMMERCIAL LAND ZONING: M-2 2" TAP, 2" G.V., 2" SERVICE, 2" METER IN BOX & 2" BFP IN HOT BOX. 2" TAP CONNECTION TO 6" FIRE LINE (1) 8"X6" TEE, (1) 6" G.V. (2) 8" G.V. & (1) REDUCER (8" TO 6") 8" WATER MAI N I/ / FL 10.00' BUFFER (SHARED) 8"x6" REDUCER 6" GATE VALVE & LEG, FIRE HYDRANT COMBINED SCM ACCESS & WATERLINE EASEMENT A 6" FIRE LINE WITH RPZ BFP IN HOT BOX A 13' RESTRAINED JOINT PIPE AT BENTS (TYP.)- UTILITY EASEMENT FIRE & DOM. SERVICE 'C' DETAIL SCALE 1:10 Know what's below. Call before you dig. 48" 1-RCP INV. 600.22' H FIRE & DOMESTIC SERVICE 'C' (SEE DETAIL) 6' RESTRAINED JOINT PIPE AT BENTS - FLOWS NORTH 11 1 SS MH RIM ELEV. = 613.94' INV. IN = 605.91' (8" VP) INV. OUT = 604.08' (8" VP) NEW INV. IN = 608.23' (WITH FLEXIBLE BOOT) ' 48" RCP INV. 600.14' if N12 55'42/W WET POND 1 (SEE SHEET D-5 FOR DETAILS) PATIO FIRE HYDRANT ASSEMBLY 8" x 6" TEE LEG AND FIRE HYDRANT HOTEL (WEST) 80 ROOMS (4-STORY) FFE= 615.20' 8"-22 1/2° FIRE HYDRANT ASSEMBLY (TYP) 8"X6" TEE LEG AND FIRE HYDRANT- 2BIKE RACKS ° FLOWS NORTH RT£_—_ -HERE - MEDIUM DUTY ASPHALT PHASE 2 ALL PARKING AREAS SHALL CONFORM TO THELIGHTING AND LANDSCAPING REQUIREMENTS OF THE CITY OF MEBANE. EXISTING POND GPIN 9804922987 PARCEL ID 170381 TOLLINGWOOD-HAWFIELDS LLC DB 2835/293 PB 73/102 VACANT COMMERCIAL LAND ZONING: M-2 HEAVY DUTY ASPHALT 30' WATERLINE EASEMENT TRANSFORMER PAD DUMPSTER ENCLOSURE FOR SOLID WASTE AND RECYCLING SHALL BE BRICK OR BLOCK TO MATCH BUILDINGS (TYP.)- NEW 30' SANITARY SEWER EASEMENT ALONG EXISTING OUTFALL WITHIN SITE L=432.50' R=5655.20' CH=N 79 52'41 "E CH. DIST=432.39' 13' RESTRAINED JOINT PIPE AT BENTS (TYP.) STREETSCAPE (PROPERTY LINE TO S.S. EASEMENT) WIDTH VARIES �J���:1-Efi�trt 8"- 45° BENDS - _ S PAINTED CROSS -WALK _ - (TYP.) -.� - - 8"x8"TEE ---- (3) 8" GATE VW " VALVE RETAINING WALL WITH FENCE - PHASE 1 HOTEL (EAST) 103 ROOMS (4-STORY) FFE= 624.65' 3 BIKE RACKS ADA RAMP (TYP.) SEE TYPE 2 ON DETAIL SHEET (2) LP -5' CONCRETE SIDEWALK (MIN.) 2BIKE ._- RACKS= = WET POND 2 (SEE SHEET D-6 FOR DETAILS) 40' COMBINED WATER & SS EASEMENT MEDIUM DUTY ASPHALT GREASE TRAP ACC. RAMP (TYP.) ■ _ DOGHOUSE MANHOLE #1 Ss 8"- 45° BENDS 13' RESTRAINED JOINT LENGTH (TYP.) FIRE HYDRANT ASSEMBLY. 12"x6" TEE, LEG & FIRE HYDRANT FIRE & DOMESTIC SERVICE'B' (SEE DETAIL) SSMH #2 WAIVER REQUEST FOR 10' SHARED BUFFER ALONG LOWE'S PROPERTY ADA RAMP (TYP.) SEE TYPE 2 ON DETAIL SHEET I OFFICES OVER RETAI 5,000 SF/FLR (2-STORY) FFE= 625.10' C/O (4) 45° BENDS WITH- REQD. RESTRAINTS FOR WATER CROSSING A PUBLIC ROAD RIGHT-OF-WAY SHALL BE EXTENDED THROUGH THIS SOUTHEAST PORTION OF THE DRPBS PROPERTY FOR THE EXTENSION OF LOWE'S BLVD. THAT IS PART OF THE FUTURE THROUGHFARE PLAN THAT HAS BEEN APPROVED BY THE CITY OF MEBANE. R/W DELINEATION AND SPECIFICS WILL BE DETERMINED AT A LATER DATE. 12"x12"TEE (2) 12" GATE VALVE (1) 12" PLUG \ SSMH #5 40' COMBINED SAN. & WATER EASEMENT 30" STANDARD CURB & GUTTER (TYPICAL) HEAVY DUTY ASPHALT LP (LIGHT POLE TYP.) SSMH #3 SS FLOWS WEST SS SS MH RIM ELEV. = 624.83' INV. IN = 616.60' (8" VP) INV. OUT = 615.86' (8" VP) 4" SERVICE, 3" WATER METER IN BOX, 3" BFP IN HOT BOX. STRIPED PEDESTRIAN CROSSING (TYP.) ALL PEDESTRIAN CROSSINGS SHALL BE ADA COMPLIANT AND ALL RAMPS SHALL HAVE TRUNCATED DOMES 12"x8"TEE (1) 12" GATE VALVE (2) 12" x 8" REDUCER (2) 8" GATE VALVE FIRE HYDRANT ASSEMBLY 12"x6" TEE, LEG & FIRE HYDRANT FIRE & DOMESTIC SERVICE 'A' (SEE DETAIL) 40' COMBINED S.S. & WATER EASEMENT 4" S.S. SERVICE WITH CLEANOUT 5' FROM PROPERTY LINE FOR POSSIBLE FUTURE USE w/ 20' EASEMENT SSMH #4 SS GPIN 9814037566 PARCEL ID 163487 LOWES HOME CENTERS INC. DB 2065/997 PB 68/376 DISCOUNT STORE ZONING: B-2 UTILITIES LEGEND EXIST / N 0Go w PROPOSED N Y 1 1I I ►L w • • • • G G G OHE OHE UGE ss ss ss v //// //// //// //// //// //// //// //// GENERAL NOTES: WATER VALVE FIRE HYDRANT WATER METER BACKFLOW DEVICE FIRE DEPT. CONNECTION (FDC) REDUCER PLUG & BLOCK MECHANICAL JOINT / BEND POST INDICATOR VALVE (PIV) AIR RELEASE VALVE (ARV) SANITARY SEWER MANHOLE SEWER CLEAN OUT CURB INLET DROP INLET JUNCTION BOX FLARED END SECTION (FES) EXISTING WATER MAIN PROPOSED WATER MAIN / SERVICE EXISTING GAS MAIN PROPOSED GAS MAIN EXISTING OVERHEAD ELECTRIC PROPOSED UNDERGROUND ELECTRIC EXISTING SEWER MAIN PROPOSED SEWER MAIN / SERVICE EXISTING STORM PIPE PROPOSED STORM PIPE HEAVY DUTY ASPHALT MEDIUM DUTY ASPHALT 1. PROJECT BOUNDARY AND EXISTING TOPO TAKEN FROM FIELD SURVEY PROVIDED BY SUMMIT DESIGN & ENGINEERING SERVICES. 2. TRAFFIC IMPACT ANALYSIS HAS BEEN APPROVED BY THE CITY OF MEBANE AND NCDOT. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF MEBANE AND/OR NCDOT STANDARDS AND SPECIFICATIONS, LATEST VERSIONS. 4. ALL LANDSCAPING & LIGHTING TO MEET CITY OF MEBANE UDO REQUIREMENTS. 5. ALL SIGNAGE SHALL BE INSTALLED IN ACCORDANCE WITH MUTCD & CITY OF MEBANE STANDARDS. 6. DRIVE AISLES AND DRIVEWAYS SHALL BE HEAVY DUTY ASPHALT AND PARKING AISLES SHALL BE STANDARD DUTY ASPHALT. 1" TAP CONNECTION — TO 4" FIRE LINE 1" TAP, 1" BALL VALVE, 1" SERVICE WITH 1" METER IN BOX & 1" BFP IN HOT BOX. HIGH VISIBILITY CROSSWALK- PAINT SHALL MEET NCDOT STANDARDS 1, • 8 A I11111 toworrist lOtag Q o F6 I 4" FIRE LINE WITH RPZ BFP IN HOT BOX W _ 12"X4" TEE & 4" G.V. 12" WATER - MAIN FIRE & DOM. SERVICE 'A' DETAIL SCALE 1:10 RE -STRIPE END OF LOWES BLVD. AS SHOWN TO ALLOW FOR TRUCK TURN RADII. MATCH EXISTING STRIPING USING PAINT MEETING NCDOT STANDARDS. STRIPING TO BE REMOVED SHALL ALSO BE PER NCDOT STANDARDS. N8931'07'E 271. 0' (TIE) 'Al N8929'24"E 248.50' EXIST. 12" WATERLINE REMOVE PLUG & EXTEND 12" WATER MAIN AS SHOWN NEW 5' WIDE CONC. SIDEWALK EXTENDED TO THE INTERSECTION MATCH EXISTING CURB OFF -SET AS EXISTING SIDEWALK TO THE EAST CROSS -SLOPE SHALL BE 4'/FT MAX. ST MH RIM ELEV. = 639.49' INV. IN = 633.79' (18" RCP) INV. OUT = 632.88' (24" RCP) LOWES BLVD. (60' WIDE PUBLIC RIGHT OF WAY) EXIST. YELLOW DOUBLE LINE GPIN 9814026895 PARCEL ID 163481 COMPASS POINTE CENTER OWNERS ASSOC. DB 3387/540 PB 76/410 COMMERCIAL COMMON AREA ZONING: B-2, M-1 & M-2 wv 30" RCP FLOWS NORTH I TPED 4' CATCH BASIN RIM ELEV. = 643.02' INV. IN = 637.29' (10" PVC) INV. IN = 634.60' (24" RCP) INV. IN = 632.36' (24" RCP) INV. OUT = 632.30' (30" RCP) JG 24" RCP TRANSFORMER ON CONCRETE PAD ST M H RIM ELEV. = 639.38' INV. OUT = 634.32' (18" RCP) GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET) 1 inch = 40 ft. J 0 m N N N DATE m o z o 0 m z a m o 0 >- 1- 0 REVISIONS �CO��MNrJ ENGINEERING SERVICES DRAWING ALTERATION w w O�wza°O~>u:02 0wWW0V0wfn > w �w=zzUwa� p O¢Q Z (n_O W W W ° ~ iFd¢w¢ L< w � - ate'a w U¢¢> o O m LL p F U OF a °p 10 0, o�=o�z�=�zo z c7, 01_ XW�z O Z Q W Z~ J f/J O ¢Vo>¢a�a 0QUw>>wOz=c[ �rnzcn!)). Oarfn U w_ p ¢ L w Q E-pLu n°go �� I Z i (PROJECT ENGINEER/ARCHITECT TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER i GS (GOVINDA.SEDHAY@SUMMITDE.COM) FIRST ISSUE DATE 0 NOT FOR 1 \\���\11111111/��,„ \\� `, C^^nn /, OT. S�\\,. NY A• ��T�IIIIIII����\ CONSTRUCTION) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 l PROJECT NO. 18-0156 DRAWING NAME: 18-0156_S.dwg SHEET NO. C-5 1 vil\Current Drawings \18-0156 G.dwg, C-6 GRADING & DRAINAGE PLAN, 5/23/2022 4:37:29 PM, govinda.sedhay, N:\2018\18-0156.010 - DRPB Hospitality LLC - Mebane Ho GRADING & STORM LEGEND: EXIST / PROPOSED 111111 SD • 0 CM SD LD/TP LD/SF LD 100 98 100 LD/TP LD/SF 98 CURB INLET DROP INLET JUNCTION BOX FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE & TREE PROTECTION FENCE LIMITS OF DISTURBANCE & SILT FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE PROPOSED SWALE HEAVY DUTY ASPHALT MEDIUM DUTY ASPHALT - !48.52 10.00' BUFFER (SHARED) GPIN 9804922987 PARCEL ID 170381 TOLLINGWOOD -HAWFIELDS LLC DB: 2835/293 PB: 73/102 VACANT COMMERCIAL LAND ZONING: M-2 l Know what's below. Call before you dig. / l J l 604� �6�6021j i 613.0 612.55 GPIN 9804922987 PARCEL ID 170381 TOLLINGWOOD-HAWFIELDS LLC DB 2835/293 PB 73/102 VACANT COMMERCIAL LAND ZONING: M-2 - l \ EX. GRADE 48" 1-RCP INV. 600.22' FLOWS NORTH 1 1 11 48" RCP INV. 600.14' W . W W606 -747 606 z/ W -"606.50-'� o in o io CO CO CO - 61-4 S - - 4 613.83 EXISTING POND 2.5_ 5' NEW CONCRETE SIDEWALK 2.5' INSIDE R/W WITH 2' SHOULDER @1/4 " PER FT. (MAX.) 5' EX. C&G 2" 60' R/W SS MH RIM ELEV. = 613.94' INV. IN = 605.91' (8" VP) INV. OUT = 604.08' (8" VP) NEW INV. IN = 608.23' (WITH FLEXIBLE BOOT) 615.6 \14.12 HOTS (WEST) 80 ROOMS (4-STORY) FFE= 615.20' EXISTING ROADWAY 614.6 PHASE 2 MEDIUM DUTY ASPHALT LOWES BLVD. TYPICAL SECTION "A -A" NTS FLoN'S NORTH HEAVY DUTY ASPHALT 617.58 L=432.50' R=5655.20' CH=N79 52'41 "E CH. DIST=432.39' 6 6\0 / // / / .1�Z3� 02- 617'3 1- - 1-79 ---fir .1G 615• - 614.12 .--'f4-6S-- 617.00 VARIES EX. C&G 619,64 -619.24-- �.1s_.�o- _ „1-4.-6_0-- 6..5 61.08 N INTERSTATE TE TH PUBLIC RIGHT OF WAY) 615 (VARIABL -614 / 613- - �= 0.34 - 619_84- - 61982- - .•36 - .233 623. c 624.14-.23_18 - 209 LF +/- PROPOSED RETAINING WALL 4- -ems - _ �z3 os - CP NN-- 21.45 620.95.2 --6225 - 62223- 622.02 624.64- 623.16 624.6' - 624.10 • - 621.18 624.10 623.85 623.95 616- 619 620 624.10 623.70 620.77 622.1 6216� FL 23.60 622.00 24.50 623.25 - --- - 624.91 - 56- - __ - 8-25,1 6-24768 24.35 / 623.99 250 - -- . -622700- - 624.11 623.60 OFFICES OVER RETAIL 5,000 SF/FLR (2-STORY) FFE= 625.10' 10'Lx5'Wx22"D CLASS B RIP RAP OUTLET PROTECTION - 616- 620.31 \ 620` SS 21.00 620.50 SS SS FLOWS WEST SS SS MH RIM ELEV. = 624.83' INV. IN = 616.60' (8" VP) INV. OUT = 615.86' (8" VP) GPIN 9814037566 PARCEL ID 163487 LOWES HOME CENTERS INC. DB 2065/997 PB 68/376 DISCOUNT STORE ZONING: B-2 HASE LINE MEDIUM DUTY ASPHALT HEAVY DUTY ASPHALT GPIN 9814031565 PARCEL ID 163482 HARRY P ISLEY & J. MACK ISLEY JR. DB 911/162 PB 68/376 VACANT -COMMERCIAL LAND ZONING: B-2 626.18 \ A 26.50 626.00 26.01 64 625.51 6214 .26.75 625.25 SECTION "A -A" PIPE SCHEDULE NAME LENGTH SIZE SLOPE START INVERT IN END INVERT OUT P-1 30.01' 15" 1.67% ST-1 620.50 FES-1 620.00 P-2 53.25' 15" 2.91% ST-2 622.15 ST-1 620.60 P-3 46.73' 15" 7.49% ST-3 620.00 616.50 P-5 36.93' 18" 0.81% ST-5 615.30 FES-3 615.00 P-6 96.10' 15" 4.24% ST-6 622.57 ST-5 618.50 P-7 73.97' 18" 0.54% ST-7 615.80 ST-5 615.40 P-8 73.11' 15" 1.09% ST-8 619.50 ST-7 618.70 P-9 127.09' 15" 0.55% ST-9 616.60 ST-7 615.90 P-10 92.63' 15" 0.97% ST-10 617.60 ST-9 616.70 P-11 95.76' 15" 1.04% ST-11 620.00 ST-10 619.00 P-12 35.74' 24" 0.84% ST-12 606.80 FES-7 606.50 P-13 139.67' 24" 0.64% ST-13 607.80 ST-12 606.90 P-14 135.57' 21" 0.52% ST-14 608.60 ST-13 607.90 P-15 64.06' 21" 0.62% ST-15 609.10 ST-14 608.70 P-16 74.72' 15" 0.80% ST-16 609.80 ST-15 609.20 P-17 107.73' 15" 0.56% ST-17 610.50 ST-16 609.90 P-18 56.42' 15" 2.48% ST-18 612.00 ST-17 610.60 P-19 75.01' 18" 0.53% ST-19 609.60 ST-15 609.20 P-20 63.92' 18" 0.63% ST-20 610.10 ST-19 609.70 P-21 170.80' 18" 0.64% ST-21 611.10 ST-20 610.00 P-22 69.95' 15" 1.00% ST-22 611.90 ST-21 611.20 P-23 190.28' 15" 0.79% ST-23 613.50 ST-22 612.00 P-24 77.92' 15" 1.41% ST-24 614.70 ST-23 613.60 STRUCTURE DATA FES-1 (FES) RIM = 623.30 INV IN = 620.00 (P-1) FES-2 (FES) RIM = 623.50 FES-3 (FES) RIM = 619.54 INV IN = 615.00 (P-5) FES-7 (FES) RIM=611.58 INV IN = 606.50 (P-12) ST-1 (CI) RIM = 625.30 INV IN = 620.60 (P-2) INV OUT = 620.50 (P-1) ST-2 (CI) RIM = 626.80 INV OUT = 622.15 (P-2) ST-3 (CI) RIM=624.16 INV OUT = 620.00 (P-3) ST-5 (CI) RIM = 622.80 INV IN = 615.40 (P-7) INV IN = 618.50 (P-6) INV OUT = 615.30 (P-5) ST-6 (CI) RIM = 625.67 INV OUT = 622.57 (P-6) ST-7 (CI) RIM=623.10 INV IN = 615.90 (P-9) INV IN = 618.70 (P-8) INV OUT = 615.80 (P-7) ST-8 (CI) RIM = 622.60 N8931'07'E 271.70' (TIE) W LP vt.I vt.I N89 29'24'E 248.50' EXIST. 12" WATERLINE LD ST-9 (CI) RIM = 623.25 INV IN = 616.70 (P-10) INV OUT = 616.60 (P-9) ST-10 (JB) RIM = 625.21 INV IN = 619.00 (P-11) INV OUT = 617.60 (P-10) ST-11 (CI) RIM = 624.04 INV OUT = 620.00 (P-11) ST-12 (CI) RIM = 612.57 INV IN = 606.90 (P-13) INV OUT = 606.80 (P-12) ST-13 (CI) RIM = 613.92 INV IN = 607.90 (P-14) INV OUT = 607.80 (P-13) ST-14 (CI) RIM = 616.90 INV IN = 608.70 (P-15) INV OUT = 608.60 (P-14) ST-15 (CI) RIM = 618.50 INV IN = 609.20 (P-19) INV IN = 609.20 (P-16) INV OUT = 609.10 (P-15) ST-16 (CI) RIM = 615.34 INV IN = 609.90 (P-17) INV OUT = 609.80 (P-16) ST-17 (CI) RIM = 613.70 INV IN = 610.60 (P-18) INV OUT = 610.50 (P-17) ST-18 (CI) RIM = 614.12 INV OUT = 612.00 (P-18) ST-19 (CI) RIM = 621.20 INV IN = 609.70 (P-20) INV OUT = 609.60 (P-19) NEW 5' WIDE CONC. SIDEWALK EXTENDED TO THE INTERSECTION ST MH RIM ELEV. = 639.49' INV. IN = 633.79' (18" RCP) INV. OUT = 632.88' (24" RCP) LOWES BLVD. (60' WIDE PUBLIC RIGHT OF WAY) -Qt./ EXIST. YELLOW DOUBLE LINE GPIN 9814026895 PARCEL ID 163481 COMPASS POINTE CENTER OWNERS ASSOC. DB 3387/540 PB 76/410 COMMERCIAL COMMON AREA ZONING: B-2, M-1 & M-2 WV Ge �� TPED ST-20 (CI) RIM = 620.95 INV IN = 610.00 (P-21) INV OUT = 610.10 (P-20) ST-21 (CI) RIM = 619.22 INV IN = 611.20 (P-22) INV OUT = 611.10 (P-21) ST-22 (CI) RIM = 617.49 INV IN = 612.00 (P-23) INV OUT = 611.90 (P-22) ST-23 (CI) RIM = 620.27 INV IN = 613.60 (P-24) INV OUT = 613.50 (P-23) ST-24 (CI) RIM=621.70 INV OUT = 614.70 (P-24) 30" RCP FLOWS NORTH I 4' CATCH BASIN RIM ELEV. = 643.02' INV. IN = 637.29' (10" PVC) INV. IN = 634.60' (24" RCP) INV. IN = 632.36' (24" RCP) INV. OUT = 632.30' (30" RCP) JG 24" RCP TRANSFORMER ON CONCRETE PAD ST M H RIM ELEV. = 639.38' INV. OUT = 634.32' (18" RCP) GRAPHIC SCALE 20 0 10 20 40 80 (IN FEET) 1 inch = 40 ft. J 0 m N N N DATE m o z o 0 w z a m o >- 1- 0 REVISIONS `N Cr) C\J - ENGINEERING SERVICES DRAWING ALTERATION w w OO_,ZzNo oQ°OWE> u a W W J Q V 0 w� �w - wz U w p 0pO¢Q Z (n_O W W W ° ~ iFdw�=WQQ ate' w UQ> V O m LLO FOF¢°pc zi LL O�=�zrn=�z0 O�:9U9C; OFxxwOz Z Q WZ~ J f/) O Vo>L�Q- - �QxwOzc[rnzcn°�~Ofnu)w❑wwU Z ° p m Z (PROJECT ENGINEER/ARCHITECT TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER GS (GOVINDA.SEDHAY@SUMMITDE.COM) FIRST ISSUE DATE NOT FOR.4.c ESSlO`/ /IIIIIII\\\ CONSTRUCTION.) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 00 N n en N 00 00 zN M bA t•-• 0 y U 0 7-1 CV ti CV CO Z W Z W 0 J CO CO W 0 J l z /Q 0 (W `/ z_ NQ C0 0 co rW V z 0 0 PROJECT NO. 18-0156 DRAWING NAME: 18-0156_G.dwg SHEET NO. C-6 1 vil\Current Drawings \18-0156 PP.dwg, C-7 ROAD PROFILES, 5/23/2022 3:56:31 PM, govinda.se N:\2018\18-0156.010 - DRPB Hospitality LLC - Mebane Ho UD SSMH #1 RI M=620.550', duo SANITARY SEWER 'A OUTFALL- PROFILE STA: 10+50 WATERLINE 1 PROFILE STA: 15+85 (SEE SHEET C-8 FOR CONTINUATION) Fu C/O WITH END CAP �SSMH #2 werweinenorw — S (95) iv ST-11-s `RIM=624.044'., C/O SSMH #3) ST-2 RIM=626.804' ST-10 `RIM=625.211' 6" PVC SS SERVICE LINE PROPOSED BUILDING SANITARY SEWER OUTFALL 'A' & WATERLINE 1 CONTINUATION STA. 10+00-16+70 Yil 640 635 630 O O 0 0 625 - 620 SEE SHEET C-8 FOR WL-1 CONTINUATION. 615 610 605 600 0) Tt 0) 0) L() O CO RI M IN` (2) 45° HORIZONTAL BEND L— — FIRE HYDRANT 0 N AAA STA: Pipe 0 CO 1- 0 0.6 1% ZD N z z FINISHED GRADE 3' MIN. COVER —+ O.59 LF, cnR 35, 8" PVC Pipe @ 0.64% CO I I rn� u)c , 1 O 1- 0 0 Lf) I I bD Z Z Z Amu 1 • EXISTING GRADE CO CO N CO 1 u ---1n1L n ocy, LO M CO CO 8" G.V. 12"TO " REDUCER 8" W/L w2 12" G.V. 4' MIN. COVER 12" DIP WATERLINE 174.41 LF, SDR 35, 8" PVC Pipe @0.61% IL io co -OD CO CO N N CO CO CC II II II I I • OD 1- 0 187.70 Z Z Z > > > > Z Z Z Z ST-2: '� LF, SDR 35, 8" PVC Pipe @ 0.60°/,61 0 0 CO H 0 640 635 0 0 630 cn rn N 4m � II U — — R 625 (NiEn N CO H 0 z z (4) 45° VERTICEL BENDS W/ RESTRAINTS (TYP) I I I 620 0) r ii 615 • aD 1- 0 Z LO LO O CO N N CO N CO O CO N 0 CO CO N CO CO N co Ln CO L() r CO V CO O W CO CO 00 CO 00 CO N 00 CO N CO O CO V O CO CO N L() O CO 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 SANITARY SEWER OUTFALL 'A' & WATERLINE 1 CONTINUATION STA. 10+00-16+70 610 605 600 Ln O CO 16+50 16+70.01 CONNECT TO WATER MAIN GRAPHIC SCALE 40 0 10 20 40 80 (IN FEET) 1 inch = 40 ft. 1 C. cri 0 m N CN CN C. DATE CITY OF MEBANE COMMENTS Cn z 0 cn i I-- CO d- Cr) N N- 1 ENGINEERING SERVICES DRAWING ALTERATION w W OOw'Z vwi W= F Liy U Z ow: O Z } O a�ovWd¢o`-o zW�r>3W¢ ¢ �l oZ ZN0Oa� 0 w ).,Cr 0 W O W2'--YW WOZ< w Fw ¢FQ=,La¢ a W o O Z Oj O m� w �FO�Qpu)�Fw =�Z=�zo OZ° Z w F 0QZWOOHHZ=K O Z W 0 O F O O <cnw?oO¢��0 o Oo ¢wU(7Z ¢ (A 7 Z Q 0 H� w z Q 1 TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER I } m z Q GS (GOVINDA.SEDHAY@SUMMITDE.CO FIRST ISSUE DATE I NOT FOR rEAGINE�'••,`�� '���llllllll,,\\\ CONSTRUCTION) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 Lu Z NJ I..V Lu oes J 0 PROJECT NO. 18-0156 DRAWING NAME: 18-0156_PP.dwg SHEET NO. C-7 1 /., PROPOSED BUILDING ST-16 ,RIM=615.340' j „.000 CLEAN OUT (TYP.) B 4 ST-24 RIM=621.700' WATERLINE 1 PROFILE STA.10+50 SANITARY SEWER OUTFALL PROFILE STA. 15+85 (SEE SHEET C-7 FOR CONTINUATION) L=432.50' R=5655.20' CH=N79 52'41 "E CH. DIST=432.39' ss / \ \ 630 625 620 8" G.V.—\ W/L #2 — 615 610 605 600 595 590 O WATERLINE 1 STA. 10+00-15+85 00 O O N N O M N I� r N O p (V (1. O 0 ± p N Q N mo t �� 0) ft< O N� w w U)U) I-H (2)45° BEND �I- 0) Q 0 F- F- m- coco FINI'H N CENTERLINE GRADE (2) 45° HORIZONTAL•• BEND I- Q r H • m ` l EXISTING GRADE j- FIRE HYDRANT co N m — � 36" MIN. — — — 1� — — c” o �- o� li H co l co COVER- —,— 1 " Gip, --- Ham—` � � \ �'1 1- O � N `7 co N — Q Q!P�G�' / a Q- V�V i 18" MIN. CLEARF FR<� � Q LT) � 01-_,- � (` � CROSSINGS (T — - - \ .11 48° ' ;, � 15" RCP .�.�� P-24 /� 11��,, , „ig 00. o_ -22 . A &'I co reen.alli. r 18" MIN. CLEAR AT S.D. I^ Cfl --. �,�����iiioi�����������""��"= A�� //////1,,,,�- o CROSSINGS (TYP.) u Eo ' 'rrmnl = o� o O �� p co o .-. E O O O N N OO co co o CO ib .-. b O r OII p0 II .- ao �_z O O O II\ f-EC) o co co II v >> D O 0 z (0 I^ l.C) _ >> m O II LC) I^ b H z 0 z • II ^ W H.- O 0 0 (0 II _ (7) L() I I z O Z >> O 0 O I^rn Ln Z b II 1- O Z Oz >> Z Z �zz z — zz > -- > Z > z Z > z > z z z _ _ — — O O oi O O N r r O 1--.O coL() co r O M O r M M O O N M �_ O M N V coCO O 00 N-:r O N O 00 O O M .1- 6) O M W O O O N I� O N (0 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 630 625 HORIZONTAL 620 T S.D. P.) 615 610 605 600 595 590 00 15+84.76 P. cn 0 - BY J N N N DATE CITY OF MEBANE COMMENTS REVISIONS VVING ALTERATION OO�wz(wox O�~ etw 5❑ U u ,p0 O O U W O Q," O }WSW-}CCJ W(<I Z _Ho Z f n W 2' LL WZZW Q OzJ>aaUoLL zo<QWUOO<<¢= OIw N� w•O°wLL j:FwWdpwZND nOOLL¢ OOLLH Z<H 5WDWO=LL O?wo0J¢wUa HLLJQWzo owz ,zo i TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER GS (GOVINDA.SEDHAY@SUMMITDE.CO FIRST ISSUE DATE r NOT FOR i\".\0Vs's'*;/ lV CD N CD / 4F CONSTRIA"UCTION J L vs DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court 00 N M 00 N M N y eb� o o U • 0-4 R. >4' z)-4 R4t z� O 0 • CI) u A r J 0 0 PROJECT NO. 18-0156 DRAWING NAME: GRAPHIC SCALE 40 0 10 20 40 80 (IN FEET) 1 inch = 40 ft. 0I 18-0156_PP.dwg SHEET NO. C-8 1 r• 1 CLEAN OUT (TYP.) ST-16 RIM=615.340', ST-15 `RIM=618.500', PROPOSED BUILDING WATERLINE 2 STA. 10+00-16+46 u ✓ Li ST-12 `RIM=612.571'� 640 635 630 625 12"W/L#1 620 615 610 605 600 ELJ 0 0 / \ — FIRE HYDRANT \\\\ FINISHED CENTERLINE GRP \ \ ST-15: 618.500 STA: 13+26.99 oCO �_ CO + M EXISTING GRADE �i �' 12" TO 8" REDUCER 8"G.V. �� 3'MIN. } I COVER — - — \ 8" W/L #1 r 8" G.V. �� v 'm — U) —� „• � o � � (1) 45° co BEND SS P-2 ( -- 18" HORIZONTAL �\ LO N m N M m — " REDUCER 48" I� 1 —m.�iiiiii 0 ii./////////m////../i..////././i, P-14, 135.6 21" RCP @ 0.52% LF /iiooiii0000i00000ioiioiioioiia�iiioioiivii�i 24" III'' ! P-13, 139.7 LF RCP o @ 0.64 /o ,I 00000 maim or0 0 co �� ao - (1) 45° HORIZONTAL BEND — zzD zzz O z D zz or 00 co 0 ii 0? z0 zz rno (Li co u z0 z_z_ -000 co H D O LO N co N N N V co 1 V LO CO -4 in V N V Cj N V �_ l.C) W 6j r 00 l.C) co. O O O V O CO j M M 6j 6) V CO r O 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 640 635 630 625 620 FIRE HYDRANT 615 610 605 600 co 16+45.88 P-12, 35.7 LF 24" RCP @ 0.84% l GS m N N N DATE CITY OF MEBANE COMMENTS REVISIONS \ ,ft ENGINEERING SERVICES DRAWING ALTERATION 1- 0 w H 0 C2 w w z z w 1- 0 w O `a TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER 1 r GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE co 1 NOT FOR C-44'c 't`� '�4'';Ns- INE•' \ �. wM' A .S\\\\`. �/,1iiiini\o CONSTRUCTION) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 ICI °•>-4' cn 1-4 4t AP-1 • o • VJ cn 0 ^ I J_ 0 a_ N z_ J PROJECT NO. 18-0156 DRAWING NAME: WATERLINE 2 STA. 10+00-16+46 GRAPHIC SCALE 40 0 10 20 40 80 (IN FEET) 1 inch = 40 ft. J 18-0156_PP.dwg SHEET NO. C-9 630 625 P-1, 30.0 LF 15"RCP @1.67% FES-2� INV=620.0' 620 615 630 625 620 0 N 0 () 0 N 0) 00 N I- (n Q H U) INVOUT(15")=620.5 ' pPaifil .- /RCP,,,000 v, 0,01/11 0 • ;�,���/%- N 0 28" S'PVC H S 0 > 12" DIP W/L co co CO 0 co ( ( 0 , - 0+00 0+50 630 625 620 1 +09-09.12 FES-1 TO ST-2 PROFILE P-5, 36.9 LF 18"RCP @0.81% FES-3- INV = 615.0' 615 610 625 620 615 610 605 O L() P-7, 74.0 LF 18" RCP @ 0.54% ") = 615.30 H 0 > Z 0in 0 Lri o0 (0() 11 11 CO LO zz z z o -op Lri 7311 1- 0 Z 0 Lri CO co L() M Ln CO co L() M Ln CO N CO FES- INV = 615.5' 630 630 co 1- u~j 625 625 620 620 615 co Lri °o (7)( 11 11 EnEn zz z z 610 co (ri N 0 0+00 0+50 1+00 1+18.20 ST-19: 621.200 0 0 0 FES-3 TO ST-7 PROFILE LO 615 630 625 620 O N CO 0+00 630 630 625 625 620 620 FES-4 INV=617.0' 615 615 N (9 0®555.68 FES-2 TO ST-3 PROFILE : 622.800 : 0+07.26 I 1 STA: 1 +03.3- CO� n off 4idpd �v 1- D 0 > Z INVOUT(18")=615.30'1 0 0LO Lri°o (7)( 11 11 0) zz z z co CO rcoco0 0 N 0 623.59 623.3 0+00 0+50 630 625 625 620 620 615 610 co N N CO 1+00+11.23 ST-5 TO ST-6 PROFILE 0 O + 0 0 0 0 co cSo O Z ZZ ST-20: 620 STA: 0+68. ST-21: 619.220 STA: 2+39.47 co 8" DIP W/L STA: 3109.37 P-20, 63.9 LF 18" RCP @ 0.63% P-21, 170.8 LF 18" RCP @ 0.64% 0 1- 0 z z z CO 11 H 0 z INV IN (15" EX. 8" PVC SS MAIN 18" 1 0 • 42'co I I U) 1- 0 Z 615 610 605 (9 ST-4: 625.208 STA' n+Rq Rn / / / / /P z4,514 LF //// RCP @ 0.97% o 0 (c O O� N 0 N 0 0+00 630 630 625 620 615 co N CO 0+50z 63.76 FES-4 TO ST-4 PROFILE IMMWA P-19, 75. ' LF 18" RUF) .53 4Y0- 00 I I 11 COF-0 625 630 620 625 615 620 610 615 605 co O 0 N 610 L() Lri (0 625 620 615 O 15" RCP ,,;///.;09�/0/ .1%7F7 L(7 0 En 1- 0 0 Ln N 0 0 + 0 S 0 > Z 00 Lri 00 O 0 II II z z z z O N N CO 630 630 625 0 co 0 in O N O O 625 air rrr 620 620 0+50 0+86.67 O N ST-10: 625.2 STA: 2+23.94 15" RCP (fl N 0 CO N CO 8" DIP- W/L 6" PVC SS SERVICE LINE 18" • O 0.5 5 co co II 0 ...... 0 (0 ........ L!7 (fl N 0 18" 15" RCP () N CO 0.97% a0 LO r N N 0 0+10� 0+50 1+00 0 Z Z z z z O > Z 1+50 Z 2+00 1- 0 Z .,,,,�,15.,R,,,,/,�;, INF IN (15" V N 0 N N CO O N CO 0 N 0 O 0 CO ST-7 TO ST-8 PROFILE ST-7 TO ST-11 PROFILE % - " D I P -/ W/L 18" CLEAN OUT CLEAN OUT ." PVC SS \ \ SERVICE LINE 18" P-10 0 Lri 1- 0 0 Lri bo > > Z Z CO N N L() 1n N L() N CO 630 625 620 615 620 610 615 605 0+00 0+50 0+85.49 0+00 0+50 1+00 1+35.74 625 620 620 615 615 oN 610 z z ST-19 TO ST-15 PROFILE SEWER SERVICE 1 PROFILE P-12, 35.7 LF 24" RCP @ 0.84% 610 FES-7 INV = 606.5' 605 605 o ooc co cc co 09 co OcoI� N.. co oN- 0 00 In O 11 `-S ON 0 O 6.1-l.C) LO �j l.C) V L!7 �j II 0+00 0+50 1+00 1+50 2+00 2+50 3+003+12.41 0+00 ®+.*4.22 z z 620 625 615 620 610 615 605 00 610 O ST-23: 620.27C 6 4" DIP- 18" SERVICE 1 STA: 15+22.00 DIP FIRE LINE ' DI / W/L ST-24: 621.700 18" 18" CTA 1R+74.17 0 7311 En 1.477 �niiiio� 5'��RCP,,,,,, � ,iiiiio 0 0 7311 I 10 X. 8" PVC SS MAIN (15") = 614.70' 1- Z_ > Z co O () co O N CO 1- O1n ZN () N 600 RIM=613.94' CLEA OUT CLEA ROUT II LI 6" PVC SS LINE I SERVICE 4-1 FLEXIBLE BOOT 11 rn Lri O 0 I I (.4Zt- N Z (V (i 1 0+50 1 +00 SEWER OUTFALL 'A' PROFILE 620 615 610 605 600 n,• •• 11.53 625 615 615 620 620 615 610 0+00 0+50 0+87.79 P-25, 35.9 LF 18" RCP @ 0.56% FES- INV = 605.8' 610 615 605 610 600 605 M CO 0 O (u 0 O 630 625 620 2+50 3+00 3+21.39 630 CLEAN OUT 625 6 PVC SG SERVICE LINE 620 615 00 #3 STA: 0+22.8 0 N 0 12"DP W/L °o CO 0+00 co (O O -N N o0 CO CO 0 CNI II II II 0000 CO CO Z Z Z > > > > Z Z Z Z 630 620 615 co 045E57.30 G" PVC SS SERVICE LINE SEWER SERVICE 2 PROFILE ST-15: 618.500 H E- - ( o 0 0 0 0 00 0 I I (`1 1- 0 + 0 1- 0 620 " DIP W/L 48" -12-45, 64 1 21" RCP @ 0 62% v. 0 O 0 H O 615 610 o0 z 205 0+00 0+45.39 0+00 0+50 0+72.28 l GS m N N N DATE CITY OF MEBANE COMMENTS REVISIONS �CO��MNNJ w OO_OOUp~= U Z Z W O Z W m Z OH W UO LL Z }Ui/JOF W J�U� ON p ¢ 7 w~ z z w- a o !Y p0U¢¢Z u, )Li W J H �Fa¢w¢�=�¢¢ W1• ^�IC7 � Wa> 8omn= LU J Z U C7 � � � � ¢ Op n p F W U=p Z=�ZO zO�zoH=xWOz • W ¢ °z¢�Wz�w�(- Py ' 0 FFp W QQd p J¢Ww>wOzw� scnz (n >u)W���w ¢ w U O Z o ¢¢ O zJw¢=oy0 z 1- 0 w 1- 2 O w w z z w 1- O w O `0_ TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER r GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE 0 u- 1 0 X x NOT FOR OTti, A SS 00,11110\00 CONSTRUCTION) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 U off., L I-4 Nt 11-1 O 0 FBI • CI) • fyis cn 0 PROJECT NO. 18-0156 DRAWING NAME: , ST-19 TO ST-22 PROFILE ST-12 TO FES-7 PROFILE ST-13 TO ST-24 PROFILE ST-25 TO FES-6 PROFILE ST-15 TO ST-14 PROFILE J 18-0156_PP.dwg SHEET NO. C-10 \N P't S 4� & $� �e P �N'� �RS PR p,B�E W \D�� v �60� p6p1� S'4.�,49" 11 Cii —748.52 I J / ( 1 l I I I 45.7 48" 1-RCP INV. 600.22' 605 604. 3J 6602 / FLOWS NORTH 1 1 1 04 _ 613- / �615 EXISTING POND POND 48" RCP INV. 600.14' 606— 1 • SS MH RIM ELEV. = 613.94' INV. IN = 605.91' (8" VP) INV. OUT = 604.08' (8" VP) 1 G P I N 9804937529 PARCEL LD 160533 JAN ISLEY RUMARKS & ALBERT RUMARKS & MILTON E. BROWN III & MARGARET I. BROWN DB 1981/659 AREA 7.102 AC 6 5 616 617 FLOWS NORTH ikMM L=432.50' R=5655.20' CH=N79 52'41 "E CH. DIST=432.39' POINT OF ANALYSIS #1 J —613 — — — / / / PRE -DEVELOPMENT DA 1 FLOW PATH (TR-55) PRE DEVELOPMENT / DRAINAGE AREA 1 6, s•7, \ s WETLAND "B" N 7 tier i MN an ma ea ilia aminnim MEME in ion ion on 7 MI MI ME MI In In MI ss / f PRE DEVELOPMENT / f DRAINAGE AREA 2 / f/ —620 ss / l s PRE -DEVELOPMENT DA 2 '- FLOW PATH (TR-55) 61,n POINT OF ANALYSIS #2 ss 11 A ss I FLOWS WEST SS— SS MH RIM ELEV. = 624.83' INV. IN = 616.60' (8" VP) INV. OUT = 615.86' (8" VP) PRE -DEVELOPMENT DRAINAGE AREAS PRE DA #1 HSG SF AC CN C IMPERVIOUS N/A 0 0.00 98.00 PERVIOUS D 212,148 4.87 77.0 0.2 PRE DA #2 HSG SF AC CN C IMPERVIOUS N/A 0 0.00 98.00 PERVIOUS D 97,230 2.23 77.0 0.2 TOTAL PRE DA 309,378 7.10 N8931'07"E 271.70' (TIE) VV N89 29'24"E 248.50' NOTES: 1. THE STREAM AND WETLANDS LOCATIONS SHOWN WERE DELINEATES IN THE FIELD BY ECOLOGICAL ENGINEERING (CARY, NC) ON MAY 24TH, 2018, AND SUBSEQUENTLY LOCATED BY SUMMIT DESIGN & ENGINEERING SERVICES ON NOVEMBER 1ST, 2018. ST MH RIM ELEV. = 639.49' INV. IN = 633.79' (18" RCP) INV. OUT = 632.88' (24" RCP) co 9P, / GV a O co wv WV 30" RCP FLOWS NORTH I Ge� TPED CATCH BASIN RIM ELEV. = 643.02' INV. IN = 637.29' (10" PVC) INV. IN = 634.60' (24" RCP) INV. IN = 632.36' (24" RCP) INV. OUT = 632.30' (30" RCP) JG ,\O Q/ 24" RCP TRANSFORMER ON CONCRETE PAD ST MH RIM ELEV. = 639.38' INV. OUT = 634.32' (18" RCP) I/VS St VD GS DATE CITY OF MEBANE COMMENTS L. REVISIONS ' . cip G SERVICES DRAWING ALTERATION )0")02- 02,:zzL ‹> _c wzz: :00_wW° 77"1 U _1 !IC/ 8- '17:6 )-3°1=1: wiln<H°U 76- LL,C t:":" ,C:ICILU2 )L. L 1::(3 OU:=<2 Z1-!) WWWW<U1-2 -1=°U zo_ 1°2> 3oLlja 0EC:U 128U) C<- Lu 0 TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER ui GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE co NOT DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court oo • Fax: (919) 732-6676 en oo oo CO o co 0 • PROJECT NO. DRAWING NAME: 2. BOUNDARY & TOPOGRAPHY INFORMATION TAKEN FROM SURVEY BY SUMMIT DESIGN AND ENGINEERING SERVICES DATED: 11/01/2018. SHEET NO. vil\Current Drawings \18-0156 G.dwg, C-12 POST-DEV DRAINAGE MAP, 5/23/2022 4:57:28 PM, govinda.sedhay, N:\2018\18-0156.010 - DRPB Hospitality LLC - Mebane Ho l Know what's below. Call before you dig. J 10.00' BUFFER (SHARED) l 6p3 -- =6021j -- 48" 1-RCP INV. 600.22' _% FLOWS NORTH 1 1 1 1 48" RCP INV. 600.14' N12 55.4 'W 24. 61 ' - W 61W W W W POST DEVELOPMENT LDRAINAGE AREA BYPASS POINT OF ANALYSIS #1 SS MH RIM ELEV. = 613.94' INV. IN = 605.91' (8" VP) INV. OUT = 604.08' (8" VP) NEW INV. IN = 608.23' (WITH FLEXIBLE BOOT) WET POND 1 . (SEE SHEET D-5 HOTS (WEST) 80 ROOMS (4-STORY) FFE= 615.20' EXISTING WETLANDS SHALL BE MITIGATED. ALL REQUIRED PERMITTING ASSOCIATED WITH THE WETLAND WILL BE PROVIDED PRIOR TO FINAL APPROVAL OF THE CONSTRUCTION DRAWINGS. EXISTING POND PHASE 2 617� FLOWS NORTH POINT OF ANALYSIS #2- L=432.50' R=5655.20' CH=N79 52'41 "E CH. DIST=432.39' / 6 610/ 611 612" N • — 61( - OFFICES OVER RETAIL 5,000 SF/FLR (2-STORY) FFE= 625.10' SS POST DEV. DA BYPASS FLOW PATH (TR-55) POST DEV. DA 1 FLOW PATH (TR-55) \\61s— \ 617 — INTERSTATE uGKwAY40&gs TH PUBLIC RIGHT OF \11AY) 615 (VARIABL -61 613— — POST DEVELOPMENT DRAINAGE AREA 1 616 —619 9 HOTEL EAST 103 ROOMS (4-S ORY) FFE= 624.65', WET POND 2 (SEE SHEET D-6 FOR DETAILS) / F�620` A SS FLOWS WEST SS SS MH RIM ELEV. = 624.83' INV. IN = 616.60' (8" VP) INV. OUT = 615.86' (8" VP) 0 J GRADING & STORM LEGEND: EXIST / PROPOSED 111111 SD • ■ PIN SD LD/TP LD/SF LD 100 98 100 LD/TP LD/SF 98 CURB INLET DROP INLET JUNCTION BOX FLARED END SECTION (FES) EXISTING STORM PIPE PROPOSED STORM PIPE LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE & TREE PROTECTION FENCE LIMITS OF DISTURBANCE & SILT FENCE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE PROPOSED SWALE POST DEVELOPMENT DRAINAGE AREAS POST DA #1 (SCM 1) HSG SF AC CN C IMPERVIOUS N/A 122,578 2.81 98.0 0.96 PERVIOUS (WOOD - GOOD) D 42,350 0.97 77.0 0.2 TOTAL 164,928 3.79 POST DA #2 (SCM 2) IMPERVIOUS N/A 53,077 1.22 98.0 0.95 PERVIOUS (WOOD -GOOD) D 30,211 0.69 77.0 0.2 TOTAL 83,288 1.91 POST DA #3 (BYPASS) IMPERVIOUS N/A 2,565 0.06 98.0 0.95 PERVIOUS (WOOD - GOOD) D 58,597 1.35 77.0 0.2 TOTAL 61,162 1.40 TOTAL POST DA 309,378 7.10 N8931'07'_E 271_70' (TIE) \II N89 29'24"E EXIST. 12" WATERLINE LP 248.50' LD ST MH RIM ELEV. = 639.49' INV. IN = 633.79' (18" RCP) INV. OUT = 632.88' (24" RCP) LOWES BLVD. (60' WIDE PUBLIC RIGHT OF WAY) WV 30" RCP FLOWS NORTH I Ge �� TPED 4' CATCH BASIN RIM ELEV. = 643.02' INV. IN = 637.29' (10" PVC) INV. IN = 634.60' (24" RCP) INV. IN = 632.36' (24" RCP) INV. OUT = 632.30' (30" RCP) JG 24" RCP TRANSFORMER ON CONCRETE PAD ST M H RIM ELEV. = 639.38' INV. OUT = 634.32' (18" RCP) GRAPHIC SCALE 20 0 10 20 40 • 80 (IN FEET) 1 inch = 40 ft. V 0 m N N N DATE 0 0 z 0 0 z m 0 L0 0 >- 0 0 REVISIONS 1`CO��Cr)CVr ENGINEERING SERVICES DRAWING ALTERATION i (PROJECT ENGINEER/ARCHITECT TAS (TIM.SMITH@SUMMITDE.COM) i GS (GOVINDA.SEDHAY@SUMMITDE.COM) C NOT FOR 1111III11111,, \\\\ '\N CAROB 1/,, SEAL 1. 030517 /// //,//Tyy A •S\\\\ /1111111\\\ `CONSTRUCTION DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 00 b N M el 00 W M Z y M bA r•-• Ch O 0 a. y U 1 CV Cr) ti N z LLJ z CO LJ 0 CO CO LLI 0 J PROJECT NO. 18-0156 DRAWING NAME: 18-0156_G.dwg SHEET NO. C-12 1 vil\Current Drawings\18-0156 EC.dwg, C-13 EC PHASE I, 5/23/2022 4:52:35 PM, govinda.se N:\2018\18-0156.010 - DRPB Hospitality LLC - Mebane Ho S' 4.5- 14u.52 GPIN 9804922987 PARCEL ID 170381 TOLLINGWOOD -HAWFIELDS LLC DB: 2835/293 PB: 73/102 VACANT COMMERCIAL LAND ZONING: M-2 J Know what's below. CaII before you dig. l LD/SF NEW TREE LINE • 604- 604 3 -6021j • 48" 1-RCP INV. 600.22' 605/� /N�5 .23 �"645E FLOWS NORTH 1. 1 1 48" RCP INV. 600.14' EXISTING POND SS MH RIM ELEV. = 613.94' INV. IN = 605.91' (8" VP) INV. OUT = 604.08' (8" VP) NEW INV. IN = 608.23' (WITH FLEXIBLE BOOT) TEMPORARY SEDIMENT BASIN #1 (SEE SHEET D-10 FOR DETAILS) DRAINAGE ARES 26,173 SF (0.60 AC) LD/SF NOTIFICATION OF LAND RESOURCES SEDIMENT AND EROSION CONTROL SELF -INSPECTION PROGRAM: r LOWS NORTH -609 L=432.50' R=5655.20' CH=N79 52'41 "E CH. DIST=432.39' STRAW WATTLES (TYP) OP-1 3'Lx2.25'Wx12"D CLASS / A FINE RIP RAP 10' WIDE SPILLWAY STABILIZE PER NCDEQ SPECIFICATION USING SOIL STABILIZATION GEOTEXTILE. SEE EC DETAILS. DRAINAGE AREAS FOR TSB #1=199,586 SF (4.58 AC) THE SELF -INSPECTION PROGRAM IS A REQUIREMENT OF THE NPDES STORMWATER PERMIT FOR CONSTRUCTION ACTIVITIES. -619 10' WIDE SPILLWAY STABILIZE PER NCDEQ 618- -- SPECIFICATION USING SOIL \`-- STABILIZATION GEOTEXTILE. 617- - SEE EC DETAILS. "THE SEDIMENTATION POLLUTION CONTROL ACT WAS AMENDED IN 2006 TO REQUIRE THAT PERSONS RESPONSIBLE FOR LAND -DISTURBING ACTIVITIES INSPECT A PROJECT AFTER EACH PHASE OF CONSTRUCTION TO MAKE SURE THAT THE APPROVED EROSION AND SEDIMENTATION CONTROL PLAN IS BEING FOLLOWED. RULES DETAILING THE DOCUMENTATION OF THESE INSPECTIONS TOOK EFFECT OCTOBER 1, 2010." - NCDEQ DIVISION OF ENERGY, MINERAL AND LAND RESOURCES THE FOCUS OF THE SELF -INSPECTION REPORT IS THE INSTALLATION AND MAINTENANCE OF EROSION AND SEDIMENTATION CONTROL MEASURES ACCORDING TO THE APPROVED PLAN. THE INSPECTIONS MUST BE CONDUCTED AFTER EACH PHASE OF THE PROJECT AND CONTINUED UNTIL PERMANENT GROUND COVER IS ESTABLISHED IN ACCORDANCE WITH NCGS 113A-54.1 AND 15A NCAC4B.0131. THE SELF -INSPECTION REPORT FORM IS AVAILABLE AS AN EXCEL SPREADSHEET FROM HTTPS://DEQ.NC.GOV/ABOUT/DIVISIONS/ENERGY-MINERAL-LAND-RESOURCES/EROSION-SEDIMENT-CONTROL/FORMS. IF YOU HAVE ANY QUESTIONS OR CANNOT ACCESS THE FORM, PLEASE CONTACT THE NCDEQ OFFICE AT (919)791-4200. N • 6 TD-1 (TEMPORARY DIVERSION DITCH #1 LINE WITH NAG S150 MATTING) TD-2 (TEMPORARY DIVERSION DITCH #2 LINE WITH NAG S150 MATTING) / 615 -614 INTERSTATE HIGHWAYS 40 & 85 VARIABLE WIDTH PUBLIC RIW STRAW WATTLES DRAINAGE AREAS FOR TSB #2=57,178 SF (1.17 AC) 10' x 10' CONCRETE WASHOUT AREA OP-2 3'Lx2.25'Wx12"D CLASS A FINE RIP RAP WETLAND "B" i ss NEW TREE LINE 1 TEMPORARY SEDIMENT BASIN #2 \ (SEE SHEET D-10 FOR DETAILS) TD-3 (TEMPORARY DIVERSION DITCH #3 LINE WITH NAG S150 MATTING) 620 SS i 1 i 50' x 25' GRAVEL CONSTRUCTION ENTRANCE/EXIT LD/SF SS FLOWS WEST SS SS MH RIM ELEV. = 624.83' INV. IN = 616.60' (8" VP) INV. OUT = 615.86' (8" VP) GPIN 9814037566 PARCEL ID 163487 LOWES HOME CENTERS INC. DB 2065/997 PB 68/376 DISCOUNT STORE ZONING: B-2 GPIN 9814031565 PARCEL ID 163482 HARRY P ISLEY & J. MACK ISLEY JR. DB 911/162 PB 68/376 VACANT -COMMERCIAL LAND ZONING: B-2 DRAINAGE ARES FOR BYPASS=11,980 SF (0.27 AC) CIP ( IP (SFO) C_TCD) CLD CLD/TP� CLD/SF� EROSION CONTROL LEGEND: EXIST / PROPOSED 111111 0 c CURB INLET • DROP INLET Q JUNCTION BOX FLARED END SECTION (FES) SF Vi//////////oo////o/ LD LD/TP LD/TP • SF SF - LD/SF LD/SF 100 Pg 100 99 CATCH BASIN INLET PROTECTION ROCK PIPE INLET PROTECTION SILT FENCE OUTLET TEMPORARY CHECK DAM STRAW WATTLES CONSTRUCTION ENTRANCE / EXIT EXISTING STORM PIPE PROPOSED STORM PIPE LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE & TREE PROTECTION FENCE SILT FENCE LIMITS OF DISTURBANCE & SILT FENCE DIVERSION DITCH EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE NOTE: "WOODS LINE" IS FOR ILLUSTRATIVE PURPOSES ONLY AND CLARITY OF THE PLANS. REFER TO THE "LIMITS OF DISTURBANCE" LINE FOR ACTUAL CLEARING LIMITS. CONSTRUCTION SEQUENCE: 1. OBTAIN APPROVED SET OF CONSTRUCTION DRAWINGS. AN EROSION AND SEDIMENT CONTROL (E&SC) PERMIT AND A CERTIFICATE OF COVERAGE (COC) MUST BE OBTAINED BEFORE ANY LAND DISTURBING ACTIVITIES OCCUR. KEEP A COPY ONSITE THROUGHOUT CONSTRUCTION. CONTACT DEMLR WINSTON-SALEM REGIONAL OFFICE AT (336) 776-9800 A MINIMUM OF 48 HOURS PRIOR TO INITIATING LAND DISTURBING ACTIVITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR NPDES REPORTING THROUGHOUT CONSTRUCTION. SEE SELF -INSPECTION PROGRAM NOTES THIS SHEET. 2. INSTALL TEMPORARY CONSTRUCTION ENTRANCE/EXIT AND MAINTAIN PER THE NOTES ON THIS SHEET D-8 AND IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL GUIDELINES. PROPOSED PIPE AT THE CONSTRUCTION ENTRANCE TO BE INSTALLED WHEN CONSTRUCTION ENTRANCE IS INSTALLED. THE ASSOCIATED DITCH LINES WILL BE STABILIZED WITH MATTING IMMEDIATELY AFTER CONSTRUCTION. ALL CONSTRUCTION TRAFFIC MUST ENTER AND EXIT THE PROPERTY AT THIS LOCATION. 3. CLEAR & GRADE ONLY AS NECESSARY TO INSTALL THE EROSION CONTROL DEVICES AS SHOWN ON THIS PLAN. INSTALL SILT FENCING, ALL SILT FENCE OUTLETS AND TREE PROTECTION FENCE AS SHOWN, AND PROVIDE SUPPLEMENTAL OUTLETS AS NEEDED IN LOCATIONS WHERE FIELD CONDITIONS INDICATE AREAS WHERE SITE RUNOFF WILL POND. AFTER SILT FENCE INSTALLATION, DEMLR WINSTON-SALEM REGIONAL OFFICE AT (336) 776-9800-TO SCHEDULE A SILT FENCE INSPECTION. THIS INSPECTION MUST BE COMPLETED AND PASSED PRIOR TO PERFORMING ANY ADDITIONAL WORK. 4. INSTALL TEMPORARY SKIMMER BASIN AS SHOWN ON THE PLAN. ENSURE THAT A STONE PAD IS PROVIDED UNDERNEATH THE SKIMMER AS A PREVENTATIVE MEASURE AGAINST IT BECOMING STUCK. ATTACH A LINE TO THE SKIMMER SHOULD IT NEED TO BE FREED AT ANY TIME. AFTER THE SKIMMER BASIN IS INSTALLED, CONTACT DEMLR WINSTON-SALEM REGIONAL OFFICE AT (336) 776-9800 TO SCHEDULE A SKIMMER BASIN INSPECTION. THIS INSPECTION MUST BE COMPLETED AND PASSED PRIOR TO PERFORMING ANY ADDITIONAL WORK. 5. INSTALL TEMPORARY DIVERSIONS DITCHES AND THEIR ASSOCIATED BERMS WITH MATTING AND STRAW WATTLES AS SHOWN DOWN SLOPE FROM CONSTRUCTION ACTIVITIES TO CONVEY SEDIMENT LADEN RUNOFF AND DIRECT FLOW AS NEEDED TO PROMOTE POSITIVE DRAINAGE TO TEMPORARY SKIMMER BASIN AS SHOWN ON PLANS. 6. TEMPORARILY SEED, MULCH, ANCHOR AND STABILIZE ALL EROSION CONTROL DEVICES IMMEDIATELY AFTER CONSTRUCTION. 7. ONCE CLEARING & EROSION CONTROL CONSTRUCTION HAS BEEN COMPLETED, CONTACT THE DEMLR WINSTON-SALEM REGIONAL OFFICE AT (336) 776-9800 FOR ONSITE INSPECTION AND APPROVAL. 8. BEGIN CUT/FILL ACTIVITIES TO OBTAIN FINISHED GRADES AS SHOWN ON THE PLANS. 9. RELOCATE/RE-ESTABLISH TEMPORARY DIVERSIONS AT THE END OF EACH WORK -DAY TO NEW CONSTRUCTED TOP OF SLOPE SUCH THAT DRAINAGE AREA TO BASIN IS MAXIMIZED AND UPLAND AREAS CAPTURED BY SILT FENCE ARE MINIMIZED. N8931'07"E 271.70' (TIE) N8929'24"E 248.50' TEMPORARY DIVERSION SCHEDULE PH 1 NAME DEPTH SLOPE (%) 025 (cfs) V25 (fps) FLOW DEPTH SHEAR MATTING TD-1 1.50 2.70% 1.77 3.19 0.43 0.72 NAG-SC150 TD-2 1.50 1.00% 0.59 1.70 0.34 0.21 NAGSC150 TD-3 1.50 1.50% 0.59 2.45 0.28 0.26 NAGSC150 ST MH RIM ELEV. = 639.49' INV. IN = 633.79' (18" RCP) INV. OUT = 632.88' (24" RCP) GPIN 9814026895 PARCEL ID 163481 COMPASS POINTE CENTER OWNERS ASSOC. DB 3387/540 PB 76/410 COMMERCIAL COMMON AREA ZONING: B-2, M-1 & M-2 ce co WV WV 30" RCP FLOWS NORTH TPED CATCH BASIN RIM ELEV. = 643.02' INV. IN = 637.29' (10" PVC) INV. IN = 634.60' (24" RCP) INV. IN = 632.36' (24" RCP) INV. OUT = 632.30' (30" RCP) JG 10 24" RCP TRANSFORMER ON CONCRETE PAD ST MH RIM ELEV. = 639.38' INV. OUT = 634.32' (18" RCP) • GRAPHIC SCALE 20 0 10 20 40 80 (IN FEET) 1 inch = 40 ft. 1 / GS m N N C N C. DATE CITY OF MEBANE COMMENTS LREVISIONS N.-C) In 71- C O N N ENGINEERING SERVICES DRAWING ALTERATION Wow,. 0 0 Cf) ,:t z¢ O O W O O> co O uJ } O O W W ui Q O EZZ O w v > z-w�Zz�W��oQQFt��ill Www~ OdQW¢=¢w�w�'U¢¢}Om= g�OOQo�o� ODI zrn . W O � OZJ„zFLLFO ¢V��¢?:I: a 0 Q Q) w Z O w O z° V)ZWNOIO >cnw?OOQ��w ¢ w O O z 0 Q ❑ nZzQ�°°go w F 2i m Z (PROJECT ENGINEER/ARCHITECT TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER 1 >- z GS (GOVINDA.SEDHAY@SUMMITDE.COM) FIRST ISSUE DATE te NOT FOR . ��11111111��. \\����11111111/��i„ '�N CARo4/ .�''. 7 \->fivoINte''• �.ATM'AS�. CONSTRUCTION) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 a) 0 7-1 N CO) ti N z W Z CO w J CO co W 0 JJ V J 0 0 I..I� z 0 U z 0 0 w PROJECT NO. 18-0156 DRAWING NAME: 18-0156_EC.dwg SHEET NO. C-13 1 vil\Current Drawings \18-0156 EC.dwg, C-14 EC PHASE II, 5/23/2022 4:52:10 PM, govinda.se N:\2018\18-0156.010 - DRPB Hospitality LLC - Mebane Ho 10' WIDE SPILLWAY STABILIZE PER NCDEQ SPECIFICATION USING SOIL STABILIZATION GEOTEXTILE. SEE EC DETAILS. `/S 40 86 RCP INV.6000.22' NWT' w -` P-���D N pUp���G RI `N� �� PR�I'`p�`` w 604- ! •• ��!i 6o6p3 6pA' ^/ N/5 n_ •5' 4g„W E) ! 48.52 LD/SF TEMPORARY SEDIMENT BASIN #1 (SEE SHEET D-5 FOR DETAILS) GPIN 9804922987 PARCEL ID 170381 TOLLINGWOOD -HAWFIELDS LLC DB: 2835/293 PB: 73/102 VACANT COMMERCIAL LAND ZONING: M-2 LF0 GPIN 9804922987 PARCEL ID 170381 TOLLINGWOOD-HAWFIELDS LLC DB 2835/293 PB 73/102 VACANT COMMERCIAL LAND ZONING: M-2 Know what's below. Call before you dig. FLOWS NORTH 48" RCP INV. 600.14' EXISTING POND (WITH FLEXIBLE BOOT) HOTEL (WEST) 80 ROOMS (4-STORY) FFE= 615.20' L=432.50' R=5655.20' FLOWS NoRTH 609 DRAINAGE AREAS FOR TSB #1=177,042 SF (4.06 AC) WETLAND "B" 613- HOTEL (EAST) DRAINAGE AREAS FOR TSB #2=99,573 SF (2.28 AC) • la WIDE SPILLWAY STABILIZE PER NCDEQ SPECIFICATION USING SOIL STABILIZATION GEOTEXTILE. SEE EC DETAILS. 615 -614 — 616— OFFICES OVER RETAIL 5,000 SF/FLR (2-STORY) FFE= 625.10' CONCRETE WASHOUT AREA TEMPORARY SEDIMENT BASIN #2 (SEE SHEET D-5 FOR DETAILS) LD/SF 623 623 ss LD/SF ss FLOWS WEST SS SS MH GPIN 9814037566 PARCEL ID 163487 LOWES HOME CENTERS INC. DB 2065/997 PB 68/376 DISCOUNT STORE ZONING: B-2 GPIN 9814031565 PARCEL ID 163482 HARRY P ISLEY & J. MACK ISLEY JR. DB 911/162 PB 68/376 VACANT -COMMERCIAL LAND ZONING: B-2 DRAINAGE ARES FOR BYPASS=11,980 SF (0.27 AC) IP (TCD) CID EROSION CONTROL LEGEND: EXIST / PROPOSED 111111 • • SF LD SF SF 100 99 99 CURB INLET DROP INLET JUNCTION BOX FLARED END SECTION (FES) CATCH BASIN INLET PROTECTION ROCK PIPE INLET PROTECTION SILT FENCE OUTLET TEMPORARY CHECK DAM STRAW WATTLES CONSTRUCTION ENTRANCE / EXIT EXISTING STORM PIPE PROPOSED STORM PIPE LIMITS OF DISTURBANCE LIMITS OF DISTURBANCE & TREE PROTECTION FENCE SILT FENCE LIMITS OF DISTURBANCE & SILT FENCE DIVERSION DITCH EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR WOODS LINE NOTE: "WOODS LINE" IS FOR ILLUSTRATIVE PURPOSES ONLY AND CLARITY OF THE PLANS. REFER TO THE "LIMITS OF DISTURBANCE" LINE FOR ACTUAL CLEARING LIMITS. 10. AFTER THE CURB AND GUTTER AND STORM PIPE SYSTEM IS INSTALLED, INSTALL INLET PROTECTION AROUND THE CURB INLETS AND DRAINAGE INLETS AND ADJUST DIVERSION DITHES AS REQUIRED TO DIRECT AS MUCH RUNOFF FROM DISTURBED AREAS TEMPORARY SKIMMER BASINS. 11. CONTINUE MAINTENANCE AND INSPECTION OF EROSION CONTROL DEVICES FOLLOWING RUNOFF PRODUCED BY STORM EVENTS. NO DISTURBED AREAS ARE TO BE LEFT WITHOUT PROTECTIVE COVER (MULCH OR STRAW/ TACK) AFTER COMPLETION OF CONSTRUCTION OR DEVELOPMENT ACTIVITIES PER THE TIME FRAMES ESTABLISHED IN THE STABILIZATION CHART ON THE EROSION CONTROL DETAIL SHEET. DURING CONSTRUCTION OR DEVELOPMENT ACTIVITIES, ANY DISTURBED AREAS SHALL BE PROTECTED AND STABILIZED ACCORDING TO THE STABILIZATION TIMEFRAME CHART ON THE DETAIL SHEET. DISTURBED AREAS FOR ANY PORTION OF THE SITE SHALL BE STABILIZED WITHIN 7 DAYS UPON COMPLETION OF CONSTRUCTION OR DEVELOPMENT ACTIVITIES IN THAT AREA. 12. NO SEDIMENT CONTROL MEASURES ARE TO BE REMOVED WITHOUT APPROVAL OF THE EROSION CONTROL OFFICER. 13. STORM SYSTEMS USED TO CONVEY STORMWATER DURING CONSTRUCTION SHALL BE CLEANED OUT PRIOR TO OWNER ACCEPTANCE AND CERTIFICATION BY THE PROJECT ENGINEER. 14. DECOMMISSION ALL TEMPORARY SEDIMENT BASINS PER THE NOTES ON AND CONVERT THEM TO THEIR PERMANENT SCM CONFIGURATION. UPON APPROVAL, REMOVE ALL TEMPORARY EROSION CONTROL MEASURES INCLUDING SILT FENCE, INLET PROTECTION, AND SEDIMENT BASIN, FINE GRADE, PERMANENTLY SEED AND STABILIZE AREAS DISTURBED FROM REMOVAL OF DEVICES AS NEEDED. INSTALL BLANKET MATTING ON ALL SLOPES 3:1 OF GREATER PER THE EROSION CONTROL DETAILS. 15. WHEN SITE IS FULLY STABILIZED, AND PERMANENT VEGETATION ID ESTABLISHED, CONTACT THE DEMLR WINSTON-SALEM REGIONAL OFFICE AT (336) 776-9800 FOR ONSITE INSPECTION AND FINAL APPROVAL. ADDITIONALLY, THE PERMITTEE SHALL CONTACT DEMLR TO CLOSE OUT THE E&SC PLAN. AFTER DEMLR INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL VISIT DEQ.NC.GOV/NCGO1 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (e-NOT). A $100 ANNUAL GENERAL PERMIT FEE WILL BE CHARGED UNTIL THE e-NOT HAS BEEN FILLED OUT. N8929'24"E 248.50' ST MH 30" RCP FLOWS NORTH ce (60' WIDE PUBLIC RIGHT OF WAY) GPIN 9814026895 PARCEL ID 163481 COMPASS POINTE CENTER OWNERS ASSOC. DB 3387/540 PB 76/410 COMMERCIAL COMMON AREA ZONING: B-2, M-1 & M-2 ST MH GRAPHIC SCALE NQI CATCH BASIN 24" RCP TRANSFORMER ON CONCRETE PAD • • GS C. DATE CITY OF MEBANE COMMENTS LREVISIONS ‘ . . k ENGINEERING SERVICES DRAWING ALTERATION woz o• w• u (1): zixiLfj 1 =0: 1 _> :› -7' :z >1: Luf:LU EW z' = ,<I 7 0°C D! zDZI2 IL U: I =°0:W1 1 <26:. >:' 2: 2ZZ<Z>: ,171 9: 2<li=HI ... 51!: -c!HDL. U riC )°°-1-IW 5:: L i jUIL )1= o° r'ZLI i< 31 -- 11- ' !C ti 1 j 03W , . . . ,_ ii6 12; i :MW u )6-17 (PROJECT ENGINEER/ARCHITECT TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER 0 >- cc GS (GOVINDA.SEDHAY@SUMMITDE.COM) FIRST ISSUE DATE NOT FOR N4oNt.t:1/41••••%, CONSTRUCTION j sji DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 CO cs1 en 00 cn cri P. CNI CO CO CO co Lu 0 Lu 0 0 0 0 Lu PROJECT NO. 18-0156 DRAWING NAME: SHEET NO. C-14 vil\Current Drawings \18-0156 LS.dwg, C-4 SIGNAGE LIGHTING LANDSCAPING & TRUCK TURNING RADIUS PLAN, 5/23/2022 4:50:35 PM, govinda.se N:\2018\18-0156.010 - DRPB Hospitality LLC - Mebane Ho ��� �V PRVPBS ,' 49„ W / 48 52 ) l J 4O °5 NB�`N 10' BUFFER (SHARED) Know what's below. Call before you dig. 48" 1-RCP INV. 600.22' H FLOWS NORTH ■■ 1 1 " RCP INV. 600.14' 48 • Yr • EXISTING POND STREETSCAPE BETWEEN PROPERTY LINE AND NEW S.S. EASEMENT. (SEE TYPICAL SECTION BELOW) Yr If Yr If RT-E -_ H ERE__ L=432.50' R=5655.20' CH=N79 52'41 "E CH. DIST=432.39' HOTELS IDENTIFYING FREESTANDING POLE SIGN (60' MAX. HEIGHT, 300 SF MAX.) Yr QTY. TREES 9 SYMBOL BOTANICAL NAME AG AMELANCHIER X 'PRINCESS DIANA' 68 IN Q ILEX NELLIE R STEVENS 45 JV 24 MG JUNIPERUS VIRGINIANA MAGNOLIA GRANDIFOLIA 63 NS ' NYSSA SYLVATICA 'RED RAGE' SHRUBS 127 60 7 14 143 74 DVJ ° GAN 0 HVI @ IVO * RBU • VDA 0 VRH PERENNIALS/ GRASSES 39,408 SF + + + + + + + + + + + + + + DISTYLLIUM VINTAGE JADE' GARDENIA JASMINOIDES 'AUGUST BEAUTY' HAMAMELIS VIRGINIANA ILEX VOMITORIA 'NANA' ROSA'BUBBLICIOUS' VIBURNUM DAVIDII PLANTING SCHEDULE COMMON NAME SERVICEBERRY HOLLY EASTERN RED CEDAR SOUTHERN MAGNOLIA BLACK TUPELO DISTYLLIUM GARDENIA CALIPER HEIGHT SPREAD ROOT SPACING NOTES 2" 8' 2.5" 10' 2.5" 10' 2.5" 10' 2.5" 10' WITCH HAZEL - DWARF YAUPON HOLLY - BUBBLICIOUS ROSE - DAVID VIBURNUM - VIBURNUM RHYTIDOPHYLLUM LEATHERLEAF VIBURNUM SEEDED LAWN: SEE PERMANENT SEEDING NOTES B&B AS SHOWN MULTI -STEM, SPECIMEN B&B AS SHOWN B&B ASH SHOWN B&B AS SHOWN SPECIMEN B&B AS SHOWN MATCHED, SPECIMEN 24" 24"-30" CONT. 4' O.C. 24" 24"-30" CONT. 4' O.C. 48" 24" 18" 24" 36" 30"-36" 24"-30" 18" - 24" 24"-30" 30"-36" CONT CONT. CONT. CONT CONT 10' O.C. 4' O.C. 2' O.C. 4' O.C. 7' O.C. LEGEND: WAIVER REQUEST FOR 10' SHARED BUFFER ALONG LOWE'S PROPERTY 0 TREE PROTECTION FENCE "LANDSCAPING REQUIREMENTS: TYPE B SEMI -OPAQUE BUFFER: SEMI -OPAQUE SCREEN FROM GROUND TO HEIGHT OF AT LEAST 6'. DECIDUOUS OR EVERGREEN TREES TO REACH MINIMUM HEIGHT OF 40' AT MATURITY; INSTALLED AT 2.5" CALIPER AND 10' HEIGHT. AT LEAST 75% OF THE REQUIRED SHRUBS SHALL BE EVERGREENS ADAPTED TO THE AREA. MAXIMUM SPACING 20' BETWEEN TREES AND 5'-8' BETWEEN SHRUBS. ONE CANOPY TREE PER 20 LINEAR FEET OF BUFFER (1054/20 = 53 REQUIRED) 1,520 LINEAR FEET OF BUFFER REQUIRED ALONG PROPERTY LINE. NOTE, 466 LINEAR FEET ARE WITHIN THE STREAM BUFFER. THE EXISTING VEGETATION IN THE STREAM BUFFER WILL BE MAINTAINED AND WILL ONLY BE SUPPLEMENTED IF NECESSARY. VEGETATION WILL BE PLANTED ALONG THE REMAINING 1,054 LINEAR FEET OF BUFFER. PROVIDED - CANOPY TREES - 75 (CONICAL EVERGREENS USED FOR A MORE OPAQUE BUFFER WHERE IT CAN HELP SHIELD THE SITE FROM THE FREEWAY.) UNDERSTORY TREES - 9 SHRUBS - 63 (89% EVERGREEN) STREETSCAPE LANDSCAPING: ONE CANOPY TREE FOR EVERY 40 LINEAR FEET OF STREETSCAPE. (301/40 = 8 REQUIRED) ONE UNDERSTORY FOR EVERY 20 LINEAR FEET OF STREETSCAPE. (301/20 = 16 REQUIRED) SHRUBS SHALL BE PLANTED TO MEET THE INTENT OF THE STREETSCAPE. 301 LINEAR FEET OF STREETSCAPE REQUIRED. PROVIDED - CANOPY TREES - 8 EVERGEEN CONICAL TREES - 20 (TO CREATE A MORE OPAQUE SCREEN AT THE FREEWAY) EVERGREEN SHRUBS - 23 STORMWATER CONTROL POND SCREENING: - STORMWATER DEVICES MUST BE SCREENED WITH EVERGREEN PLANTING. PROVIDED - A SCREEN OF 36 EVERGREEN CONICAL TREES IS SHOWN. PARKING LOT SCREENING: -- PARKING LOTS ARE TO BE SCREENED FROM THE STREET WITH EVERGREEN SHRUBS TO A MINIMUM HEIGHT OF 3'. PROVIDED - A SCREEN OF EVERGREEN SHRUBS IS PROVIDED ARE AROUND THE PARKING LOT. TRASH CONTAINMENT SCREENING: -- IF THE TRASH CONTAINMENT AREA WILL NOT BE VISIBLE FROM THE STREET, NO SCREENING IS REQUIRED. PROVIDED - TO HELP BEEF UP THE PERIMETER BUFFERS, EVERGREEN SCREENING IS SHOWN. J SIGNAGE NOTE: ALL FREESTANDING AND BUILDING MOUNTED SIGNS WILL BE COORDINATED THROUGH THE CONSTRUCTION DRAWING PROCESS AND SHALL MEET MEBANE UDO REQUIREMENTS. N8931'07"E 271.70' (TIE) N8929'24"E 248.50' TREE PLANTING AND STAKING: STAKING - SEE TREE PLANTING AND STAKING DETAIL ON SHEET L-2. WRAPPING - WRAP ONLY THIN BARKED TREES IF THEY HAVE BEEN REMOVED FROM SHADE TO WHERE THE TRUNK IS EXPOSED TO DIRECT SUNLIGHT DURING THE DAY. WRAPPING SHOULD BEGIN AT THE BOTTOM AND WORK UP. WRAPPING MATERIAL SHOULD NOT TRAP OR HOLD WATER. PRUNING - CLEANLY PRUNE DAMAGED BRANCHES AND ROOTS AT THIS TIME. ADDITIONAL PRUNING SHOULD BE ONLY FOR SHAPING PURPOSES. PLANTING - ALL SYNTHETIC MATERIALS SHALL BE CLEARED FROM THE ROOTS, TRUNK AND CROWN OF THE PLANT. THE ROOT BALL MEDIUM SHOULD BE SHAKEN GENTLY FROM THE ROOT BALL IF IT IS A SOILESS MIXTURE. LOOSEN AND SPREAD THE ROOTS IN THE PLANTING HOLE. DAMAGED ROOTS AND ROOTS WHICH ENCIRCLE THE TRUNK SHOULD BE CLEANLY PRUNED. SET THE PLANT SO THAT IT WILL BE AT ITS ORIGINAL DEPTH OR SLIGHTLY ABOVE EXISTING GRADE. BACKFILL WITH SOIL FROM THE HOLE. TAMP AND WATER THE SOIL TO PREVENT AIR POCKETS. DO NOT AMEND THE SOIL AT THIS POINT EXCEPT TO AMEND THE PH. WATERING - THE BACKFILL AND ROOTS OF ALL NEWLY SET PLANTS SHOULD BE WATERED AS BACKFILLING IS BEING DONE SO THAT THE SOIL AND ROOTS ARE THOROUGHLY SOAKED. MULCHING - ALL PLANTING BEDS (NOT INCLUDING SEEDED AREAS) ARE TO RECEIVE MULCH TO A DEPTH OF TREE PROTECTION FENCING: PROVIDE FENCING TO A MINIMUM HEIGHT OF 4' TO REMAIN IN PLACE UNTIL THE COMPLETION OF THE PROJECT. NO MATERIALS ARE TO BE STORED WITHIN THE DRIP LINE OF EXISTING TREES. NO VEHICLES ARE PERMITTED WITHIN THE DRIPLINE OF EXISTING TREES. NOTES : 1. TREE PROTECTION BARRIERS OR FENCING SHALL BE MAINTAINED FOR ALL COMMON SPACES, STREAM BUFFERS, AND TREE SAVE AREAS UNTIL ALL SITE WORK IS COMPLETE. NO GRADING OR LAND DISTURBING ACTIVITIES SHALL BE ALLOWED IN AREAS IDENTIFIED TO BE PROTECTED UNLESS APPROVED BY ZONING ADMINISTRATOR. 2. A LANDSCAPE PLAN MEETING ALL UDO REQUIREMENTS SHALL BE SUBMITTED AND APPROVED BY THE CITY OF MEBANE PRIOR TO FINAL CONSTRUCTION PLAN APPROVAL. PLANTINGS WITHIN STREETSCAPE AS REQUIRED TO PROVIDE OPAQUE SCREEN RAN _NEW S.S. EASEMENT._ 1-40/85 STREETSCAPE TYPICAL SECTION NTS LOWES BLVD. 1 L (60' WIDE PUBLIC RIGHT OF WAY) 30" RCP FLOWS NORTH i TPED RIM ELEV. = 643.0 INV. IN = 637.29' INV. IN = 634.60' (' INV. IN = 632.36' INV. OUT = 632.3( JG ^O Q/ 24" RCP TRANSFORMER ON CONCRETE PAD 20 0 GRAPHIC SCALE 10 20 40 80 (IN FEET) 1 inch = 40 ft. 4' J 0 !b N N N DATE m o z o 0 m z a m o 0 r 1- 0 REVISIONS I`CO��Cr)CVr ENGINEERING SERVICES DRAWING ALTERATION (PROJECT ENGINEER/ARCHITECT TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER GS (GOVINDA.SEDHAY@SUMMITDE.COM) FIRST ISSUE DATE r NOT FOR \ CI,,�� TNY .S7``\` IIIIIIII��� CONSTRUCTION.) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 CV Cr) ti CV z uJ z CO w 0 J CO CO w 0 J l z J 0 Lu U 0 z �J J PROJECT NO. 18-0156 DRAWING NAME: 18-0156_LS.dwg SHEET NO. LS-1 1 1 4,000 PSI AIR ENTRAINED CONCRETE 12" CONSTRUCTION JOINT 4 - #5 CONT 3" CLEAR 16" MIN. SURFACE COURSE BINDER COURSE CONCRETE/ASPHALT JOINT DETAIL NTS SEAL 1/2" DEEP HOLE W/ MORTAR PRECAST CONCRETE WHEELSTOP NTS RESERVED PARKING L� MAXIMUM PENALTY $250 G.S. 20-37.6 WHITE BACKGROUND ALL TEXT & LINES ARE GREEN CORNER RADIUS 1 1/2" (TYPICAL) LETTERS, BORDER AND NUMBERS ARE GREEN WHITE SYMBOL ON BLUE FIELD WHITE BACKGROUND 3/8" 7-3/8" ARROW IS GREEN BOTTOM wi OF SIGN 12" -1 R7-8E 1 /2" RAD 1' 6" ( ACVA aL 1 RESERVED PARKING MAXIMUM PENALTY $250 c0 ACCESSIBLE PARKING SIGN 0 2' 1'-6" 3" RAD 1 /8" RAD SPILL -\ 4 °. MIN. 3,000 PSI .CLASS "A" CONCRETE CONTROL JOINTS SHALL BE PLACED AT 10' INTERVALS EXPANSION JOINTS SHALL BE PLACED „ AT 30' INTERVALS AGGREGATE BASE COURSE COMPACTED SUBGRADE 24' CURB AND GUTTER NTS 19' VAN 9' MIN MAX 2% ANY DIRECTION 9.0' 18' VAN ACCESSIBLE NOTE: PARKING STRIPES, ARE TO STRIPES, A MINIMUM OF 2 COATS. PARKING SPACES NTS 2.5'R 19' 9.0' 1.5'1 EOP REGULAR SPACE w/ CURB BE 4" WIDE WHITE (NCDOT STD 1205.01) - TYPICAL LOCATE AT EDGE OF PARKING SPACE UNLESS ACCOMPANIED BY "VAN" LETTERING ACCESSIBLE PARKING SYMBOL NTS NIL law ■ \ • LOWES ISLV D, r y • NEW DOUBLE YELLOW LINES lr�trl4Fi"� L NEW MINI SKIP LINES s. 100' la:: • RESTRIPE LEFT TURN LANE TRANSITIONS AS SHOWN TO PROVIDE 240 FEET OF STORAGE FOR LEFT ONTO NC HWY. 119 4• NEW SINGLE WHITE LINE ▪ (EXTEND AS REQUIRED) • LOWES BLVD. LEFT TURN LANE ENHANCEMENT EXHIBIT NOTE: ALL PAVEMENT STRIPING SHALL BE PER NCDOT STANDARDS. • APur r 25 0 12.5 25 25 9— ti 1' it7 100 (IN FEET) 1 inch = 50 ft. 2'-6" 6" 2'-0" 1/2" RAD. APO 12" 6" CURING COMPOUND NOTES: 1. 3,000 PSI CONCRETE CURB. 2. EXPANSION JOINT EVERY 90' AND CONTRACTION JOINT EVERY 10'. 3. PROVIDE SEALANT OVER EXPANSION JOINTS AS PER NCDOT STANDARD SPECIFICATIONS. CITY OF MEBANE STANDARD 5" 7,, I ST-8 30" STANDARD CURB SCALE: N.T.S. DATE: 7/1/21 'DRAWN BY: WDF RAMP/LANDING (5'X5) 6" X 12" CONCRETE CURB SIDEWALK WIDTH-5' MIN. 3.5' 2'L X 5'W DETECTABLE WARNING SURFACE SEE DETAIL & NOTE 1, 2 & 4 EXPANSION JOINT 3.5' 3.5' 5 SIDEWALK AREA 2.5' WIDE GRASS STRIP 30" ROLLED CURB & GUTTER 2'L X 5'W DETECTABLE WARNING SURFACE SEE DETAIL & NOTES 1, 2 & 4 /F DESIGN CALLS FOR A SINGLE CROSSING, OMIT RAMP IN DIRECTION NOT NEEDED, SUBJECT TO APPROVAL BY CITY ENGINEER. EXPANSION JOINT 3.5' O 8.33% (12:1) MAX. RAMP SLOPE 2O CROSS SLOPE: 2.00% 3O CURB RAMPS REQUIRE A (5'-0') MINIMUM LANDING WITH A MAXIMUM GROSS SLOPE AND LONGITUDINAL SLOPE OF 2.00% WHERE PEDESTRIANS PERFORM TURNING MANEUVERS. SLOPE TO DRAIN TO CURB. 4O CAST IN PLACE TRUNCATED DOMES MUST BE USED ON ALL NEW CURB RAMPS. RAMP/LANDING (5' X 5), TYP. SIDEWALK AREA 2.5' WIDE GRASS STRIP 30" ROLLED CURB & GUTTER ST-9 CITY OF MEBANE STANDARD CURB RAMP SCALE: N.T.S. I DATE.: 7/1/21 I DRAWN BY: WDF 30" CURB 2'L X 5'W DETECTABLE WARNING SURFACE SEE NOTES 1 & 2 12:1 MAX 6" X 12" CONCRETE CURB MAY NOT BE REQUIRED WITH ROLLED CURB 2% MAX VARIES 5' SECTION NOTES: 1. DETECTABLE WARNING DOMES SHALL COVER 2'-0" LENGTH AND FULL WIDTH OF THE RAMP FLOOR AS SHOWN ON THE DETAILS. 2. THE RAMP MAY BE YELLOW IN COLOR OR ANY COLOR WITH A 70% CONTRAST RATIO. 3. PROVIDE SEALANT OVER EXPANSION JOINTS AS PER NCDOT STANDARD SPECIFICATIONS. 0.9" (TYP.) SECTION FULL WIDTH OF RAMP 5' MIN. O O O oO PLAN 0.45" R (TYP.) 2'-0" LENGTH DETECTABLE WARNING DOMES DETAIL 0.20" R (TYP.) I ST-10 CITY OF MEBANE STANDARD CURB RAMP SCALE N.T.S. (DATE 7/1/21 IDRAWN BY.• WDF 5'I/1IN 1.1 6" CID STEEL BOLLARDS, TYP OF 2 BEHIND EACH CONTAI NER RE L A B L ES C oD 16' MIN. 26' MIN. CMU WITH BRICK VENEER ENCLOSURE FOR GARBAGE AND CARDBOARD DUMPSTERS. GRADE CONCRETE PAD PER GRADING PLAN FOR PROPER DRAINAGE. WOOD COMPOSITE DOUBLE GATE FOR GARBAGE AND CARDBOARD DUMPSTERS (SEE GATE DETAIL). GATE RETAINERS TO BE PROVIDED w/ MIN. 2" INSET IN DUMPSTER PAD 8" CONCRETE PAD 3,500 PSI (MIN.) I� 6.0' 10.0' 24' CLEAR OPENING (MIN.) TOP OF ENCLOSURE TO BE AT LEAST 8 FEET OR 2 FEET TALLER THAN FACILITY (WHICHEVER IS GREATER). SEE STRUCTURAL PLANS FOR WALL AND FOOTER DESIGN IF USED AS A RETAINING WALL. NNNNNNNN NNNN NNNNN NUNNUNNM 1 1 NNNNNNNN 1 NNNNN NNMPINNIINN MUNN NMNNNNMNNN NUNN UNNUM MUNNMMNNIINNIINN NMNNHNNHNN NUNN NNM UNNUM MMNMN N NUN NMNNIINNIINN NUNN UNNUM 8" COMPACTED SUBGRADE 98°/0 STANDARD PROCTOR 16.0' 8'MIN GATE OPENING = 24' LEAF = 12' HEAVY DUTY WROUGHT STEEL T-HINGE (TYP.) 7AVY DUTY DOOR SECURITY SURrACE BOLT 1 VINYL OR WOOD COMPOSITE SLATS GATE RETAINERS 1/8" TENSION WIRE WITH A 3" "EYE & EYE" TURNBUCKLE, WIRE ROPE THIMBLES AND CLAMPS. SECURE EACH END OF WIRE WITH SCREW EYEBOLTS. 2x4 TREATED WOOD STRINGER AND BRACE (TYP) PLACE LOWER END OF BRACE TOWARDS THE HINGE, NOT THE LATCH ENCLOSURE GATE CC CK LIJ CD CC Li j NOTE: 1. ACTUAL GATE TO BE FULLY OPAQUE. SLATS SHOWN WITH GAPS TO SHOW BRACING DETAIL. 2. THE DUMPSTER ENCLOSURE AND ALL APPURTENANCES SHALL BE CONSTRUCTED IN ACCORDANCE WITH ALL CITY OF MEBANE AND ORANGE COUNTY SOLID WASTE DEPARTMENT STANDARDS AND SPECIFICATIONS. 3. SEE SITE PLAN FOR PEDESTRIAN ACCESS WITHIN ENCLOSURE (4' MINIMUM WIDTH). DUMPSTER ENCLOSURE ELEVATION NTS JOINT SEALER SURFACE OF CONCRETE 4" COMPACTED SUBGRADE OR ABC NOTES: • A GROOVE JOINT 1" DEEP W/ 1/8" RADIUS SHALL BE REQUIRED IN THE CONC. SIDEWALK AT 5' INTERVALS. ONE 1/2" EXPANSION JOINT WILL BE REQUIRED AT 50' INTERVALS. A 1/2" EXPANSION JOINT WILL BE REQUIRED WHERE THE SIDEWALK JOINS ANY RIGID STRUCTURE. • FINISHED SURFACE OF SIDEWALK TO BE BROOM FINISHED, PERPENDICULAR TO TRAFFIC FLOW. • CROSS -SLOPE OF SIDEWALK SHALL NOT EXCEED 2°/o 1/8" TO 1/4" JOINT FILLER CONCRETE 3000 PSI (MIN.) 2.0"S 9.5B SURFACE COURSE 8" CABC (CRUSHED 11Plefte AGGREGATE BASE COURSE) MPS... Leigtoigtostostoigtoigem LIGHT DUTY ASPHALT NEW PARKING SPACES 2.0"S 9.5B SURFACE COURSE 3.5" 119B COURSE AGGREGATE BASE COURSE) HEAVY DUTY ASPHALT LOADING AREA & DRIVE AISLES 5" CONCRETE (4,000 PSI MIN ) • 4" CABC (CRUSHED AGGREGATE BASE COURSE) HEAVY DUTY CONCRETE TRUCK / LOADING AREAS NOTE: TYPICAL SECTIONS ABOVE ARE BASED ON RECOMMENDATIONS FROM GEOTECHNICAL REPORT PREPARED BY SUMMIT DESIGN AND ENGINEERING SERVICES, DATED 10/18/2018. ASPHALT/CONCRETE PAVING RECOMMENDATIONS NTS FINISHED GRADE 6" ENCASE IN CONCRETE (TYPICAL) ROUND CONCRETE TOP OF PIPE SMOOTH 6" DIA. GALVANIZED SCHEDULE 40 STEEL PIPE FILLED WITH CONCRETE PAINT OSHA YELLOW PAINT CONCRETE BLACK AFTER CURING AT ASPHALT LOCATIONS WHERE GUARDPOST OCCURS ABOVE FOOTING, START PIPE AT TOP OF FOOTING TYP. LINE POST 7 GA. BOTTOM TENSION %/ARE rip. TOP RAIL CONNECTION AS SHOWN - 20' 0.C. GALV. PIPE 10' FtAll END 2"x2"x9 GA. FABRIC KNUCKLED TOP & BOTTOM ALL WIRE FABRIC SHALL BE BLACK VINYL COATED AND FENCE HARDWARE SHALL BE GALVANIZED & PAINTED BLACK. 3500 psi CONCRETE pePICAL LINE POST FOOTING POST CAP POST BAND DRAW BAR TERMINAL POST 2 ALL CORNERS & INTERSECTIONS 3500 psi CONCRETE TYPICAL CORNER POST FOOTING GS DATE CITY OF MEBANE COMMENTS L. REVISIONS ' . cip G SERVICES DRAWING ALTERATION z,,,,j02- 1=0<c: w0 :Z z!L. cmji -7z00)7 _LI 0: <zo. u: olze :Hz<z: uz .c,,ED5w !pi !DI au os. oc,:z Lnu - Liz _pc7 Mz'Lli —1 TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER 0 ui C NOT ,„\\\\.\y, CARQ -44S- uj z 0 CC • OD a CD ISSUE DATE co DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court oo cv Fax: (919) 732-6676 oo co t csi 1-4 1-4 cn CO LLJ o 0 PROJECT NO. 18-0156 DRAWING NAME: 18-01 56_D.dwg SHEET NO. SIDEWALK DETAIL NTS BOLLARD DETAIL NTS CHAIN LINK FENCE DETAIL -i (-6' WALL PART SECTION 6" WALL 1-LH PART SECTION 8" WALL/4" LIP PART SECTION OF END ELEVATION PART SECTION 6" WALL/4" LIP --I F-8" WALL PART SECTION 8" WALL TABLES OF QUANTITIES FOR PIPE SET IN PAD PIPE D "W' DIM "Wl" DIM -T" DIM C.Y. QUANIR1ES WHEAL IS 12" 16' 20' 12' 1'-1 7/8" 0'-7 7/8' 0'-1 3/4' 0.005 0.007 0.008 15" 1'-3 5/8" 0'-9 1/8" 0'-9 7/8' 0.006 0.008 0.010 18' l'-5 1/4" 0'-10 3/8" 0'-2" 0.007 0.010 0.012 24" l'-8 3/4" 1'-0 1/8" O'-2 1/2" 0.011 0.014 0.018 30" 2'-0 1/4" 1'-2 3/4' 0'-2 3/4' 0.014 0.018 0.023 36" 2'-3 3/4' 1'-5 3/8" 0'-3" 0.017 0.023 0.025 42" 2'-7 1/8" 1'-7" 0'-3 1/2" 0.075 0.030 0.036 46" 2'-10 5/8" 1'-8 3/4- 0'-4' 0.028 0.038 0.047 54' 3'-2 1/8" 1'-10 1/2' 0'-4 1/2" 0.035 0.047 0.058 60' 3'-5 5/8" 2'-0 1/4" 0'-5' 0.042 0.056 0.071 66' 3'- 9" 2'-2 1/4' 0'-5 1/2" 0.050 0.067 0.084 72' 4'-0 1/2' 2'-3 3/4' 0'-6" 0.058 0.078 0.098 GENERAL NOTES: THIS STANDARD SHALL BE USED WITH ALL DRAINAGE STRUCTURES USING REINFORCED CONCRETE PIPE SET IN BASE SLAB. I ST-14 CITY OF MEBANE STANDARD STANDARD CONCRETE BASE PAD FOR DRAINAGE STRUCTURES SCALE N.T.S. I DATE 7/1/21 DRAWN BY.: WDF U O w A m /4 0 7" O.C. I{6 0 7" O.C. / \ / // \\ \ / // \\ /1 // \\ Il \\ \ / (8) #5 DIAGONALS 6 1/2" Wf 2'-10 1/2" 3'-5" PLAN THE MANUFACTURER SHALL STAMP OR STENCIL ITS LOGO OR NAME IN TWO LOCATIONS ON THE SIDE OR REAR EDGES OF THE TOP A 5'-f0" (#402 INLET) /407"0.C. /6 0 7" O.C. 1" COVER SECTION B-B NOTES: 1. CONCRETE: 28 DAY COMPRESSIVE STRENGTH f'c = 4,500 PSI. 2. REINFORCING: ASTM A-615, GRADE 60. 3. ALL COVER TO REINFORCING IS 1 " 4. ALL STEEL CUT OUT FOR OPENINGS WILL BE REPLACED, 1/2 THE REINFORCING ON EACH SIDE OF OPENING. FOR USE ON #402 INLET BOX I ST-17 CITY OF MEBANE STANDARD STD. PRECAST CONCRETE CURB INLET TOP FOR STD. 402 CURB INLET SCALE N.T.S. IDATE 7/1/21 'DRAWN BY WDF 1/2" 1 1/8" 2 7/8" PLAN 19 1/2" r r by ■■\ 1 4' �w 1 1'-11 3/4" SECTION A -A 1/2" 1 1/8" 2 7/8" RING - 70 LBS. COVER - 118 LBS. U7 N SECTION B-B 3/4" ST-19 CITY OF MEBANE STANDARD INLET RING & COVER DETAIL SCALE N.T.S. !DAM 7/1/21 !DRAWN BY: WDF 4" SMALL BOX VARIES 4, 8 VARIES 4' MINIMUM DIMENSIONS FOR BRICK YARD INLET PIPE (IN) A B SMALL BOX D C E LARGE BOX D 12 2'-8" 2'-8" 3'-1 " 15 2'-8" 2'-8" 3'-3" 18 2'-8" 2'-8" 3'-6" 24 2'-8" 2'-8" 4'-0" 30 5'-0" 5'-0" 4'-6" 36 5'-O" 5'-0" 5' D" 42 �L' 6'-O" 6'-0" 5'-6" 48 6'-0" 6'-0" 6'-0" ST-20 CITY OF MEBANE STANDARD 1 STANDARD BRICK YARD INLET 12" THRU 48" PIPE SCALE N.T.S. !DATE: 7/ 1 /21 IDRAWN BY.: WDF 30" y STOP 5' MIN. (7' MIN. WHEN ADJACENT TO SIDEWALK) y 11-111-111-111-1 I 1-111-111-111 30" R1-1 MUTCD R1-1 30" X 30" GALVANIZED STEEL CHANNEL (TYP.) FINISHED GRADE STOP SIGN NTS NOTES: 10" 10" 10" VVHITE (RETROREFLECTIVE) BACKGROUND RED (RETROREFLECTIVE) BACKGROUND 1. INSTALL QUANTITY AND AT LOCATIONS REQUIRED BY CODE AND/OR AS INDICATED ON SITE PLAN. 2. ALL SIGNS SHOWN SHALL CONFORM TO N.C. MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES. 3. ALL SIGNS SHOWN SHALL BE REFLECTORIZED TO SHOW THE SAME COLOR BY NIGHT AS BY DAY. 4. ALL SIGNS SHALL BE SECURELY MOUNTED ON GALVANIZED STEEL CHANNEL POSTS. 5. ALL STOP SIGNS TO BE LOCATED WHERE THEY WILL NOT IMPACT PEDESTRIAN WALKWAYS. REFER TO SITE PLAN. 1 • OS&Y GATE VALVE INCREASER (IF NEEDED) 6" MIN. • fDISMANTLING COUPLING 1 4" GRAVITY DRAIN TO DAYLIGHT ENGINEER SHALL PROFILE DRAIN 1% MINIMUM GRADE FOR VAULT DRAIN PE STEPS ® 12" 0.C. SLOPE TO DRAIN REDUCER (IF NEEDED) OS&Y GATE VALVE 36" 6" MIN. SLOPE TO DRAIN METRON FARNIER METER • • VAULT SIZES (INSIDE DEM): 3" METER - 10'x6' VAULT 4" METER - 10'x6' VAULT 6" METER - 12'x8' VAULT 8" METER - 14'x8' VAULT DISMANTLING COUPLING OS&Y GATE VALVE BY-PASS TEE - INCREASER (IF NEEDED) 12" MIN. SLOPE TO DRAIN TOP VIEW METRON FARNIER METER BLOCKING, 2 (TYPICAL) 4" GRAVITY DRAIN TO DAYLIGHT ENGINEER SHALL PROFILE DRAIN 1 % MINIMUM GRADE FOR VAULT DRAIN THRU WALL SLEEVE WITH GROUT, (TYPICAL) ALUMINUM HATCH TPD-4872 BY PARK USA CAST INTO TOP 1' BUTYL RUBBER SEALANT IN JOINT R t0 z OS&Y GATE VALVE BY-PASS TEE REDUCER - (IF NEEDED) 3000 PSI CONCRETE SECTION (SHEET 1 OF 2) 12" MIN. SLOPE TO DRAIN NO. 57 STONE THICKEN SLAB TO 8" AT BLOCKING LOCATIONS, (TYP.) I W-21 CITY OF MEBANE STANDARD 3" - 8" METER ASSEMBLY WITH PRECAST METER VAULT SCALE NTS. (DATE: 7/1/21 I DRAWN BY: WDF PROVIDE (2) 2" HOLES FOR RADIO READ ANTENNAS STEPS AT 12" 0.C. NOTES: SECTION S&Y GATE VALVE METRON FARNIER METER BLOCKING, (TYPICAL) ALUMINUM HATCH TPD-4872 BY PARK USA CAST INTO TOP 1" BUTYL RUBBER SEALANT IN JOINT PRECAST CONCRETE VAULT ,/- - 1-VAULT WALLS TO BE THE MIN CONCRETE THICKNESS INDICATED, REINFORCED WITH NO. 4 REBAR ON 12" CENTERS EACH WAY, PLACED 2" FROM THE INSIDE WALL THE AMOUNT OF REINFORCING AND WALL THICKNESS MAY BE INCREASED FOR EXTRA DEPTH WALLS OR IN HEAVY TRAFFIC SITUATIONS AS REQUIRED BY THE ENGINEER. 2-SUBSTITUTE MATERIALS MAY BE USED AS APPROVED BY THE ENGINEER. 3-REINFORCED CONCRETE LID WITH TRAFFIC BEARING DOORS H-20 LOADING TO BE USED IN TRAFFIC SITUATIONS. 4-PROVIDE A THRU WALL SLEEVE AT OPENING IN CONCRETE OR CMU WALL LARGE ENOUGH FOR FLANGE OF PIPE TO PASS THRU. FILL VOID BETWEEN PIPE AND SLEEVE WITH NON SHRINK GROUT. 5-PIPE OUTSIDE VAULT TO BE M.J. WITH RETAINER GLANDS. 6-ALL CLEARANCE DIMENSIONS ARE MINIMUMS. 7-ALL JOINTS TO BE FLANGED THROUGH OUT VAULT. 8-STEPS ARE TO BE INSTALLED IN ALL VAULTS EXCEEDING 4 FEET DEEP AT A LOCATION FOR EASE OF ACCESS. LOCATE DOOR OVER STEPS. CONTRACTOR TO COORDINATE SIZE OF VAULT TO THE SIZE OF VAULT DOOR TO WORK PROPERLY. 9-CONCRETE TO BE A MINIMUM OF 3000 PSI. 10-ALL METERS MUST BE INSTALLED LEVEL. 11-ALL VALVES GREATER THAN 2" SHALL BE OS&Y VALVES. 12-ADDITIONAL BACKFLOW PREVENTION WILL BE REQUIRED ON ALL 3' - 8' METERS. 13-DISMANTLING COUPLING SHALL BE A SMITH BLAIR INC., 970 SERIES OR APPROVED EQUAL. (SHEET 2 OF 2) I W-22 CITY OF MEBANE STANDARD 3" - 8" METER ASSEMBLY WITH PRECAST METER VAULT SCALE N.T.S. !DATE 7/1/21 IDRAWN BY WDF 8 z m ZE ED S7IV130137N1 Sun° 6- 1/2" expansion joint materia 4 4 5' 10"12" 2'-11" • 4 • 4 8 CONCRETE CURB Jr GUTTER" • PLAN WITH TOP 8 • PLAN WITHOUT TOP NO 4 BAR EMMCEAM \ ' I 0 4 1. �,a tl CONCRETE BASE 3000 PSI • SECTION AA 5' 10 5' 2" 5" 8" 1-- 4"TOP OF CURB 1/2" EXPANSION JOINT MATERIAL 2' 0 16" 6" 1.5" 3.7" PARABOLIC CURVE 4 6" GENERAL NOTES* 1. ALL CURB INLETS OVER 4'-0" IN DEPTH TO BE PROVIDED WITH STEPS 12" ON CENTER. 2. CLASS A" CONCRETE 3000 PSI TO BE USED. 3. BRICK MASONRY CAN BE STANDARD CLAY BRICK, JUMBO BRICK, OR CONCRETE BRICK. 4. FOR 8'-0" IN HEIGHT OR LESS USE 8-INCH WALL. OVER 8'-0' IN HEIGHT USE 12-INCH WALL TO 6'-0" FROM TOP OF WALL AND 8-INCH WALL FOR THE REMAINING 6'-0". 5. IF REINFORCED CONCRETE PIPE IS SET IN BASE OF SLAB OF BOX USE STANDARD SPECIFICATION DRAWING ST-14. 6. MANHOLE RING AND COVER IN CONCRETE TOP SHALL CONFORM TO STANDARD SPECIFICATION DRAWING NO. ST-19. 7. REINFORCING STEEL SHALL CONFORM TO ASTM A-615 GRADE 60. SEAL END OF 4" PIP. AT COMPLETION OF ASPHALTIC BINDER .1. ' 6. CONC: CURB • I L 4 6" �I CLEAR SPAN • 1/2" EXPANSION JOINT MATERIAL 4 • 5' 0" * 4" CAST IRON SOIL PIPE OR PVC ASPHALT SURFACE STONE BASE PARABOLIC CURVE J' 8"� SECTION BB 8" MORTAR OR CONCRETE CROSSWALK PLACEMENT GUIDANCEI UNLESS OTHERWISE SPECIFIED, HI -VISIBILITY CROSSWALK MARKINGS SHOULD BE USED AT MID -BLOCK CROSSINGS, SEE DETAIL 'C' 4' MIN., SEE NOTE 5 4' MIN. TO STOP BAR HI -VISIBILITY CROSSWALK, SEE DETAIL 'C' STANDARD CROSSWALK- 0" MIN. WHITE TRANSVERSE LINES WITH 6' MIN. GAP BETWEEN THE LINES CURB & GUTTER SIDEWALK STOPBAR 4' MIN. 4' X 4' CLEAR SPACE, SEE NOTE 6 DETAIL 'A'- DUAL CURB RAMPS STOPBAR CURB & GUTTER 4' MIN. SIDEWALK 2' MIN. SEE NOTE 7 2' MIN. 4' X 4' CLEAR SPACE, SEE NOTE 6 DETAIL 'B'- SINGLE DIAGONAL CURB RAMP 24" MAX. WIDTH 24" MIN. GAP 8' MIN. WIDTH DETAIL 'C'- HI -VISIBILITY CROSSWALK GENERAL NOTES: 1- USE THE DETAILS ABOVE AND THE FOLLOWING NOTES FOR GUIDANCE IN PLACING CROSSWALK MARKINGS. REFER TO NCDOT ROADWAY STANDARD DRAWINGS, MUTCD AND ADA STANDARDS FOR ADDITIONAL GUIDANCE. 2- THE LOCATION AND TYPE OF CROSSWALK MARKINGS SHOWN ON THE ABOVE DETAILS ARE FOR REFERENCE ONLY. LOCATE CROSSWALK MARKINGS AS SHOWN ON THE PROJECT DETAIL SHEETS OR AS DIRECTED BY THE ENGINEER. THE CROSSWALK MARKING TYPE, STANDARD OR HI -VISIBILITY, SHALL BE INSTALLED AS SPECIFIED ON THE PROJECT DETAIL SHEETS OR AS DIRECTED BY THE ENGIMEER. 3- THE STANDARD CROSSWALK I8 TWO WHITE 8" MIN. TRANSVERSE LINES WITH A 6' MIN. GAP BETWEEN THE LINES. THE HI -VISIBILITY CROSSWALK IS WHITE 24" MAX. WIDE LONGITUDINAL LINES WITH 24" MIN. GAPS BETWEEN LINES, SEE DETAIL 'C'. HI -VISIBILITY CROSSWALKS SHOULD BE A MINIMUM OF 6' WIDE. CURB RAMPS SHALL BE WHOLLY CONTAINED WITHIN THE MARKINGS, EXCLUDING ANY FLARES. 4- STOP BARS SHOULD BE PLACED A 4' MIN. IN ADVANCE OF NEAREST CROSSWALK LINE. 5- SET BACK DISTANCE FROM INSIDE CROSSWALK MARKING TO NEAREST EDGE OF TRAVEL IS 4' MIN. 6- BEYOND THE BOTTOM GRADE BREAK, A CLEAR SPACE OF 4' X 4' MIN. SHALL BE PROVIDED WITHIN THE MARKINGS. 7- SINGLE DIAGONAL CURB RAMPS WITH FLARED SIDES SHALL HAVE A SEGMENT OF CURB 2' MIN. LONG LOCATED ON EACH SIDE OF THE CURB RAMP AND WITHIN THE NARKED CROSSING, SEE DETAIL 'B'. 8- CURB RAMPS SHALL BE CONSTRUCTED IN ACCORDANCE TO THE LATEST NCDOT ROADWAY STANDARD DRAWINGS. CURB RAMPS THROUGH MEDIAN ISLANDS, SINGLE RAMPS AT DUAL CROSSWALKS OR LIMITED R/W SITUATIONS, WILL BE HANDLED BY SPECIAL DETAILS. CONTACT THE CONTRACT STANDARDS AND DEVELOPMENT UNIT FOR DETAILS 0R A SPECIAL DESIGN. ROADWAY STANDARD DRAWING FOR N CD Z 1-1 hd cCC 1- Z w W 'a d PEDESTRIAN CROSSWALKS SHEET 1 OF 1 1205.07 PREFAB. ALUMINUM FENCE SECTION H I I-. CONCRET FENCE POST INSTALLATION POSTS 6' O.C. (MAX.) SLOPE SECTIONS OF FENCE TO FOLLOW GRADE AT TOP OF WALL II -III - RETAINING WALL _ -� I I - (SEE WALL DETAILS) - HORIZONTAL RAILS 3/4 " SQUARE PICKETS WITH SPACING LESS THAN 4" BETWEEN PICKETS FINISHED GRADE NOTES: 1. FENCE SHALL BE PAINTED BLACK. CONTRACTOR TO SUBMIT SAMPLES FOR APPROVAL. 2. REFER TO RETAINING WALL DETAILS INCLUDED WITH THIS SET FOR FENCE PLACEMENT AND FOOTING DEPTH. 17 2" SQUARE POST 1" X1.5" -\ RETAINING WALL DECORATIVE FENCE (TYP.) NTS 8" MIN. LOW PERMEABLE SOIL KEYSTONE CAP UNIT 111 APPROXIMATE LIMITS OF EXCAVATION (RETAINED SOIL) 4" PERFORATED PVC 11 DRAINAGE TILE KEYSTONE COMPAC III UNIT UNIT DRAINAGE FILL (3/4" CRUSHED ROCK OR STONE) GEOGRID REINF. DESIGN HEIGHT FINISHED GRADE NOTE: WHEN SITE CONDITIONS UNREINFORCED CONCRETE REQUIRE, WRAP DRAINAGE TILE IN 3/4" OR CRUSHED STONE AGGREGATE AND FILTER FABRIC WITH FOUNDATION SOID LEVELING PAD DRAINAGE COMPOSITE OR AGGREGATE BACK DRAIN SYSTEM, AS DIRECTED BY GEOTECHNICAL ENGINEER. TYPICAL REINFORCED WALL SECTION COMPAC III UNIT - 1" SETBACK D3 co jOM 'A8 NMM10I S71V130 137N1 SNnO 0) SEAL END OF 4" PIPE AT COMPLETION OF ASPhALTIC BINDER 4" CAST IRON SOIL PIPE OR PVC PLAN ASPNALT SURFACE STONE BASE H Milt EQUALLY SPACED EQUALLY SPACED 1 1/2" 4 BARS PLAIN OF TOP SLAB 3" /4 BARS If EQUALLY SPACED • SECTION S-S 1 1/2"] DIMENSIONS FOR BRICK CURB INLET DIMENSIONS OF BOX AND PIPE SLAB DIMENSION REINFORCING PIPE SFAN WIDTH WIDTH HEIGHT BARS U BARS V BARS W 5 6 NOTES: INSTALL ALL STEPS PROTRUDING 4" FROM INSIDE FACE OF STRUCTURE WALL. STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THE CONTRACTOR HAS FURNISHED THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. 1-181 STATE OF NORTH CAROLINA DEPT. OF TRANSPORTATION DIVISION OF HIGHWAYS RALEIGH, N.C. .---4t --1- _ 1" ....,.. ROADWAY STANDARD DRAWING FOR DRAINAGE STRUCTURE STEPS PLAN SIDE ELEVATION PLAN SIDE ELEVATION . r 4.1 Ti r- 1 P 1 .1-P f i gl L V-o" ..] CAST IRON CAST IRON ELEVATION ELEVATION #8 BAR GALV'D. NT 3 did. 12 LP 11/AVAWAWAWAUP Vio 1 POLYPROPYLENE PLAN PLASTIC 3,t- SIDE SIDE ELEVATION ELEVATION it" PLAN •:::: Pflf REINFORCING STEEL 1444._ 12 1 / \f1flqi- ELEVATION STEEL ROD SECTION A -A SANITARY SEWER MANHOLES. ELEVATION SHEET 1 OF 1 840.66 GS : DATE BY) cv CITY OF MEBANE COMMENTS REVISIONS ', CA CA cip CD CD G SERVICES DRAWING ALTERATION 0_1 11 wz> U LuW<L U _0: U \ LL I: 00U < _I Li :170z, opc:j2z^ccHa owiL c!"LciLjr- uzi :cf.), 1 Liu::: :Lijo' -() Ezu!' zzi CD CD TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER ui up GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE DESIGN AND ENGINEERING SERVICES CARyl State License #: P-0339 320 Executive Court • oo 4.4 Fax: (919) 732-6676 on oo oo 1-4 0 CD cn 0 0 0 0 oes PROJECT NO. 18-0156 DRAWING NAME: SHEET NO. D-2 1 TYPICAL SECTION STREETS TYPICAL SECTION OUTFALL CLASS 'B" CONCRETE COLLAR AROUND MANHOLE COVER IN PAVED AREAS ROAD SHOULDER OR PAVED STREETS 12 MIN. BASE 2-4" GRADE RINGS MAXIMUM ON ALL MANHOLES WRAP OUTSIDE JOINT WITH EXTERNAL JOINT WRAP, TYP. SEALANT BETWEEN JOINT, TYP. 3,000 P.S.I. CONCRETE 5" 1 TRACER WIRE IS REQUIRED IF PVC PIPE IS USED UNDISTURBED 17 EARTH II- 16" -n" r BOOT GROUT -3"MIN. C. f. M.H. RING AND COVER BY U.S. FOUNDARY OR EQUAL. SEE DETAIL SS-5 III-111- 5" CLASS 'B" CONCRETE �r TYPE "M" MORTAR 2 3/4" ANCHOR BOLTS (REDHEADS) 2' MIN. INSTALL TRACER WIRE BETWEEN TOP OF CONE AND MH RING. TIE TRACER WIRE OFF AT STEPS. w ER 4'-8" MAX. III 1 III III II III II -111-111=111= II-1 -1 I- 1 I III III II II III-III=I 6" 8" COPOLYMER POLYPROPYLENE M.H. STEPS ® 16" 0.C. BY M.A. INDUSTRIES, INC., PS1-PF NO. 67 STONE, COMPACTED NOTES: 1. MANHOLES ARE TO BE AS MFG. N.C. PRODUCTS OR APPROVED EQUAL. 2. GROUT ALL JOINTS FROM INSIDE. CITY OF MEBANE STANDARD STANDARD PRECAST MANHOLE SCALE: N.T.S. IL1A7E 7/1/21 I DRAwN eY WDF 4- 1/2- X 13/4" HEXHEAD, STAINLESS STEEL BOLTS AT 90° COUNTERSUNK. BOLTS TO BE TYPE 316 STAINLESS STEEL. (FOR WATERTIGHT MANHOLES) BOTTOM OF COVER 7 1/2" 3/4" OR 1/2" TOP OF COVER RING & COVER WILL BE MACHINED AND WILL CONFORM TO ASTM A48, CLASS 30B MINIMUM AVERAGE' WEIGHTS RING COVER TOTAL 1/4" 190 LBS. 120 LBS 310 LBS. 3/4" MIN. `1 1/2" 1/2"� 3 V 4 3/8" 1.-10 1/4" 4 3/8" 2'- 1/2" 2'-9I 1/4" SS-5 CITY OF MEBANE STANDARD MANHOLE RING & COVER SCALE N.T.S. 'DATE: 7/1/21 IDRAWN BY WDF PROPERTY LINE PVC HUB WITH 4" PVC CLEAN OUT CAP 4" CLEAN OUT (3'-0" ABOVE GRADE) 4" LONG SWEEP ELBOW TRACER WIRE (IF PVC PIPE IS USED) 4" - 1/8" BEND 4" P.V.C. SCH. 40 TRACER WIRE J (IF PVC PIPE IS USED) USE WIRE NUT TO CONNECT TRACER WIRES TOGETHER, TYP. PLAN TAPE TRACER WIRE TO STACK AS REQUIRED BEDDING STONE PROFILE SEWER MAIN NOTE: PLUMBER TO CONNECT TO STUB-OUT/STACK AND LOWER CLEAN -OUT CAP TO GROUND LEVEL SEWER MAIN I SS-6 CITY OF MEBANE STANDARD SEWER SERVICE CONNECTION SCALE N.T.S. I DATE: 7/1/21 'DRAWN BY.: WDF COMPACTED BACKFILL CRUSHED STONE INCLUDE BEDDING IN PIPE COST 0'-12' DEPTH =11111111=111=1111111111=111=11=111 ,,III-111-111-111. -111F CLASS "C" 4" BEDDING 12'-24' DEPTH COMPACTED BACKFILL CRUSHED STONE INCLUDE BEDDING III III III III IIIIIIII-III-III-II=II-III- I1E0111=III=III III=III III=i" IN PIPE COST CLASS "B" 1/2 0.D. 4" BEDDING COMPACTED BACKFILL CLASS "C" CONCRETE CRUSHED STONE 24' PLUS DEPTH INCLUDE BEDDING ' IIIIT1111111111111111111111111111111IpI11lilll=lllIll IP` IN PIPE COST CLASS 'A" BEDDING I SS-7 CITY OF MEBANE STANDARD SANITARY SEWER BEDDING SCALE N.T.S. IRATE 7/1/21 'DRAWN BY WDF 1' MIN. WIDTH OF EXCAVATED 1 " MIN OPENING CLASS "A" CONCRETE PAVEMENT (8" MIN. THICKNESS) 1 " DEEPER THAN EXISTING PAVEMENT TO BE SAWED 36" MINIMUM -111=11= vy 11fi TI-IT-� 1 =1.. -III-III- . . . . 111E1 11E111E11 =111 1 -III-III- . . . . . :IIIIII1 T1-IT-� 1 -III-III- -IT-III- 11E111E1 11E111E11 -III-III- =1I1-111E . . . . . . . 11=111=1 11E111E11 I I-1 11- 111=111E 111 1-1 f=-I 1=1_I =1 f- -III-III- . . . . . . . :III-111__. 11E111E111 El I -I 1 I- =111=III= III=111=1 11E111E11 -III-I I I- -I I I=1 I I- 111=111=1 11E111E11 =1 11=1 11= -III-III- . . . . . . . 111E111E1 11E111E11 -1 I I -I I I- =111-III- . . . . . . . III=111E1 1_I1111I 111111= -1I 1-111E 1 11E111E1 11=111=11 =1 11=1 11= -III-III- . . . . . . . III=III=1 11 FH I+ =1I1=1I1= III -III- . . . 111=III=1 11=111=11 =1 I I -I I I- -III -III- . . . 111E111E1 11-111=11 -III-I I I- 11=111- 111=111=1 11=III=1 P ° =III=111- -III-111E - 111=1I1=1 11=WI11 - T < -III-II1- -III-II1E ° ... :. 111 III 1 11-111=11-111-111=11 f-111-111-111-111-11-111-111= =111 111=1 1=1 I r 11=1 1=1 1=1 I rI 1=1 r 1=1 I 1 HEI111 1111 III 111 rn HI 111 III III 1111-11111IlllE 111 NOTE: WHERE THE EDGE OF THE PATCH OR SECTION OF REMOVED PAVEMENT IS LESS THAN 10' FROM A TRANSVERSE EXPANSION OR CONTRACTION JOINT OR CRACK, THE ENTIRE SECTION OF PAVEMENT SHALL BE REMOVED UP TO THE JOINT OR CRACK AND REPLACED WITH NEW CONCRETE AND ABC STONE IN ACCORDANCE WITH THE MOST CURRENT N.C.D.O.T. STANDARD SPECIFICATIONS. THE BACKFILL SHALL BE MADE IN 6" LAYERS AND SHALL BE COMPACTED TO AT LEAST 95% OF STANDARD DENSITY (AASHTO METHOD T-99). EACH LAYER MUST BE THOROUGHLY TAMPED BY A MECHANICAL TAMP BEFORE THE NEXT LAYER IS PLACED. 111=111-111 11E111E111=I =1I 1=111=111= 11E111E111=_ -I 11=111-111- III 111 IT-111=111- EXISTING PAVEMENT 3" COMPACTED STONE AS DIRECTED BY ENGINEER 12" SUBGRADE BACKFILL (SEE NOTE) UNDISTURBED SOIL PIPE STONE STABILIZATION (IF REQUIRED BY THE ENGINEER) SS-19 CITY OF MEBANE STANDARD CONCRETE DRIVEWAY REPAIR DETAIL SCALE N.T.S. DATE 7/1/21 DRAWN BY WDF jOM A8 NMI ?10I NOIIV77V1SNI 1NVb'OAH 3b+13 HYDRANT TEE W/ 6" BRANCH 3,000 PSI CONCRETE BLOCKING AMERICAN DARLING OR CLOW IF VALVE BOX IS NOT IN PAVED AREA, PROVIDE A 7-0" X 2'-O" CONCRETE COLLAR (TYP. OF ALL VALVES) CAST IRON VALVE BOX 6" GATE VALVE 6" DUCTILE IRON PIPE VARIES 18" MIN. 20" MAX. 2" 6" DUCTILE IRON PIPE SUPPORT VALVE WITH CONCRETE BLOCKING VARIES **MEGA -LUG FROM TEE THROUGH VALVE TO HYDRANT CAP RUST-OLEUM OIL BASED BRIGHT WHITE BARRELL RUST-OLEUM OIL BASED TRACTOR RED #57 WASHED STONE BY CONTRACTOR UNDISTURBED EARTH 3,000 PSI CONCRETE BLOCKING BOLTS, NUTS AND DRAIN PORTS TO BE FREE OF CONCRETE MINIMUM 6" CONCRETE PLACED UNDER BASE CMU BLOCKS MAY BE TO SUPPORT HYDRANT WHILE POURING BLOCKING 7-1 jOM 'A8 NMV210I SON38 - SM00781SfWH1 6" MIN.-\ CLASS B CONCRETE UNDISTURBED EARTH / TRENCH WIDTH i CLASS B CONCRETE i UNDISTURBED 4 EARTH PLAN - BENDS SECTION BUTTRESS DIMENSIONS PIPE SIZE 22 1/2 BENDS 45' BENDS 90° BENDS L H L H L H 8" 1'-O" 1'-0" 1'-4" 1'-2" 1'-10" 1'-6" 12" 1'-4" 1 '-4" 1 '-10" 1 '-10" 2'-8" 2'-3" NOTES: 1. DIMENSION "A" SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH THE MECHANICAL JOINT BOLTS 2. THE SHAPE OF THE BACK OF THE BUTTRESS MAY VARY PROVIDED THE CONCRETE IS AGAINST FIRM, UNDISTURDED EARTH. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SQ. FT. AND A WATER PRESSURE OF 150 P.S.I. jOM 'A8 NMVNOI S331 -)1007815(1 b'H1 L 1/2 L 1/2 L CLASS B CONCRETE /UNDISTURBED \ EARTH r- ( PLAN - TEE UNDISTURBED EARTH TRENCH WIDTH SECTION BUTTRESS DIMENSIONS B. D. L H C D 6" 1'-3" 1'-0" m 2 m m a m 8" 1'-6" 1'-4" P 12" 2'-3" 2'-0" m m B. D. = BRANCH DIAMETER 4 CLASS B CONCRETE NOTES: 1. DIMENSION "C" SHOULD BE LARGE ENOUGH TO MAKE ANGLE "A" EQUAL TO OR GREATER THAN 45'. 2. DIMENSION D" SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH EHT MECHANICAL JOINTS. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SQ. FT AND A WATER PRESSURE OF 150 P.S.I. jOM 'A8 NMVHOI rTI STD. CURB -\ COPPER SERVICE PIPE INSTALLED BY PROPERTY OWNER TO CITY SPEC. MAINTAINED BY CITY 10' NO ALTERATIONS NOR ADJUSTMENTS TO BE MADE IN THIS AREA WITHOUT APPROVAL OF THE U77LITIES ENGINEER. MBX-2 CAST IRON METER BOX W/HOLE IN PLASTIC LID FOR RADIO READ ANTENNA -FORD METER SETTER #VBHH74-44-44G W/ COMPRESSION FITTINGS ONLY. NO DUEL PURPOSE NUTS. ANGLE BALL VALVE WITH LOCKING WING -METRON FARNIER RADIO METER 0 rn COMPRESSION NUT FORD 1" BRASS CORPORATION COCK EQUAL SEE NOTE 1 1-1 METER Vgr VERTICAL INLET 4" WASHED STONE BALL VALVE McDONALD MODEL 6100T WASHED STONE MAINTAINED BY PROPERTY OWNER ALL WORK IN INSTALLED AS CODES Ffif / SLEEVE BACK FLOW PREVENTER W/ DUAL CHECK VALVE ASSE APPROVED 1" TYPE "K" COPPER MODEL 825Y FEBCO RPZ ASSEMBLY W/STRAINER AFTER SETTER - OR EQUAL THIS AREA TO BE PER PLUMBING 1" STRAINER 1" BALL VALVE 4" WASHED STONE CONCRETE PAD INSTALL THRE4DED UNIONS ABOVE CONCRETE PAD FOR REMOVAL 1" BRASS PIPE 1" BRASS ELBOW 1" MALE COMPRESSION FITTING (MCF) HOT BOX MODEL 1-18 2 POWER SUPPLY BY PROPER7Y OWNER 4 FLOW INSTALL AS PER PLUMBING CODE NOTE: 1) COMPRESSION FITTINGS ONLY. NO FLARED FITTINGS. DIRECT TAP ALLOWED ON D.I. ONLY. USE FORD DOUBLE STRAP BRASS SADDLE FOR AC AND PVC PIPES. 2) RPZ'S TO BE TESTED ANNUALLY. PROVIDE COPY OF TEST TO CITY. 73 CO ril cn co CD INSTALLED BY PROPERTY OWNER TO CITY SPEC. MAINTAINED BY CITY PIN VII' EQ. EQ 016 12" MIN. FROM TOP OF METER TO TOP OF METER BOX METRON FARNIER METER (ONLY IN GALLONS) MCDONALD 2" METER SETTER MBX-5 CAST IRON METER BOX W/ HOLE IN LID FOR RADIO READ ANTENNA BOX / COVER 12" TO MAIN IF UNDER PAVEMENT COPPER \ FLOW SEE DETAIL BRICK BELOW 2" MCF 2" DOUBLE STRAP BRONZE SADDLE (FORD STYLE 2029) WITH 2" NIPPLE FLOW 2" BRASS NIPPLE 2"0 BRASS SPOOL 1N3W3SV3 MAINTAINED BY PROPERTY OWNER ALL WORK IN THIS AREA TO BE INSTALLED AS PER PLUMBING CODE SLEEVE 2" TYPE "K" COPPER BRICK 30" MIN. SEPARATION METER BOX TO HAVE BRICK SUPPORTS WITH 4" OF WASHED STONE. 111 2'' MALE COMPRESSION FITTING (MCF) 2" STRAINER 2" BRASS PIPE BRASS ELBOW 2" DUCTILE IRON GATE VALVE 2" OPERATING NUT (200 P.S.L WATER WORKING PRESSURE) F6103 BY CLOW 2" BALL VALVES INSTALL THREADED UNIONS ABOVE CONCRETE PAD FOR REMOVAL, (1YPICAL) HOTBOX MODEL HB2S SLEEVE POWER SUPPLY BY PROPERTY OWNER 2" BRASS PIPE BRASS ELBOW INSTALL AS PER PLUMBING CODE 4" WASHED STONE 50"L X 24"W X 4"T CONCRETE PAD FEBCO RPZ BACKFLOW VALVE ASSEMBLY (825YBV) OR APPROVED EQUAL NOTE: 1) COMPRESSION FITTINGS ONLY. NO FLARED FITTINGS. 2) RPZ'S TO BE TESTED ANNUALLY. PROVIDE COPY OF TEST TO CITY. DO Do DEAD ENDS UNDISTURBED SOIL LR / HORIZONTAL BENDS \,x\ RESTRAINED LENGTHS, LR, FOR DUCTILE IRON PIPE NOMINAL PIPE SIZE INCHES HORIZONTAL BENDS VERTICAL OFFSETS DEAD ENDS 90' BEND FITTINGS 45° BEND FITTINGS 22 12' BEND FITTINGS DOWN BEND UP BEND DOWN BEND UP BEND DOWN BEND up BEND 909 45° 22 1/2' 4 18 7 4 31 18 13 7 6 3 31 6 25 10 5 44 25 18 10 9 5 44 8 32 13 6 58 32 24 13 11 6 58 12 45 19 9 81 45 34 19 16 9 81 VERTICAL UP BENDS NOTES 1. ALL JOINTS WITHIN THE SPECIFIED LENGTH, LR, MUST BR RESTRAINED. ALL LENGTHS ARE GIVEN IN FEET. 2. THE MAXIMUM TEST PRESSURE SHALL NOT EXCEED 200 PSL 3. THE MINIMUM DEPTH OF BURY SHALL BE 3' TO TOP OF PIPE. 4. RESTRAINED LENGTHS MAY BE REDUCED WHEN SUPPORTED BY ENGINEERING CALCULATIONS. 5. RESTRAINT SYSTEMS SHALL BE INSPECTED AND APPROVED PRIOR TO BACKFILLING. 6. MECHANICAL RESTRAINTS FOR PIPE L4RGER THAN 12" IN DIAMETER MUST BE DESIGNED BY A LICENSED ENGINEER AND APPROVED BY CITY ENGINEER. 011011111 LR UNDISTURBED SOIL VERTICAL DOWN BENDS APPROVED DEVICES A. RPZ REMOTE READOUT (GAL) 2. FEBCO SERIES LF866 DETECTOR WITH REMOTE READER (GAL.) 1. FEBCO LF825Y WITH REMOTE READER (GAL.) 2. WILKINS MODEL 975XL2 ADA WITH REMOTE READOUT (GAL) ABOVE GROUND ENCLOSURE "HEAT SOURCE TO BE PROVIDED BY OWNER" REDUCED PRESSURE DECTECTOR BACKFLOW * OR DOUBLE DETECTOR CHECK VALVE AS REQUIRED BY car OF MEBANE D.I.P. REQUIRED FROM METER TO BACKFLOW CONCRETE BLOCKING BRICK PIER GATE VALVE * NOTE: RPZ REQUIRED ON FIRE LINES WITH FIRE DEPARTMENT CONNECTIONS. 12" 3,000 PSI CONCRETE BASE DETECTOR METER - METRON 3/4" - GALLON REGISTER. MEGALUG ALL MJ FITTINGS. DITCH MUST REMAIN OPEN UNTIL BACKFLOW IS INSPECTED BY CITY OF MEBANE. OUTLET SIDE OF BACKFLOW CONCRETE BLOCKING NOTES 1. THE BACKFLOW DEVICE SHALL BE WITHIN 10' OF AND ON THE PROPERTY SIDE OF THE METER. ENCLOSURE SHALL NOT OBSTRUCT SITE DISTANCE AT ROAD CROSSINGS. 2. ALL BACKFLOW DEVICES SHALL BE INSTALLED ABOVE GROUND IN A HORIZONTAL POSITION UNLESS OTHERWISE PRE4PPROVED BY THE CITY OF MEBANE. 3. SHUT OFF VALVES SHALL BE RESILIENT SEAT WITH FLANGED END AND 0.S.&Y HAND WHEELS. 4. ALL INTERIOR AND EXTERIOR IRON SURFACES SHALL HAVE EPDXY COATINGS TO CONFORM TO ANSVAWWA C550 OR MANUFACTURED OF STAINLESS STEEL. 5. APPROVED ABOVE GROUND ENCLOSURES: "HOT BOX", HYDROCOWL, SMI MODEL b68-EHPZD, ENCLOSURE MUST HAVE A DRAIN 6. CONTRACTOR SHALL PROVIDE AND INSTALL ON EXTERIOR OF ABOVE GROUND ENCLOSURE AN EXTERIOR ANTENNA FOR DETECTOR METER. 7. TANDEM BACKFLOWS REQUIRED IF SERVING MULTIPLE USERS OR SERVICE CANNOT BE INTERRUPTED 8. DETECTOR METER AND BACKFLOW ASSEMBLY SHALL BE INSTALLED IN ENCLOSURE. 9. PIPE & FITTINGS BELOW GRADE TO BE M.J. WITH RETAINER GLANDS, 150 PSI MIN. WORKING PRESSURE. 10. INSTALL BACKFLOW DEVICE NEAR MAIN WATERLINE CONNECTION AT STREET RIGHT OF WAY. 11. ALL BACKFLOW DEVICES SHALL BE TESTED, INSPECTED, AND MAINTAINED BY THE OWNER. PROVIDE ANNUAL REPORTS TO CITY. CITY OF MEBANE STANDARD ABOVE GRADE BACKFLOW PREVENTER, 3" AND GREATER SCALE N.T.S. DATE 7/1121 'DRAWN BY: WDF GS DATE CITY OF MEBANE COMMENTS L. REVISIONS ' . o cip ( DoL:tj° ‘:ct u )2 Lii_LU; = n>-L UZ L JLCLj' n ,W5LI 12 ix< :17° 5: oul ;t‘ uz octu 0 0 0 TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER ui GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE NOT FOR EE DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court oo cv 4.4 Fax: (919) 732-6676 00 el en mt N 1-4 4t a) P-1 cn eN LLI CO LLJ o co 0 Lll PROJECT NO. 18-0156 DRAWING NAME: SHEET NO. 1 OH tLF vrS ION - - I SECTION Y-Y RISER -T. VARIES RISER HT. YA�IfS • MERE 90" TO 36' PIPE IS JSED WHERE q2" r0 54" WIPE LS USED DETA.j L S#€ 1WT. IG IUIETIIOD EF RISER CONSTRUCTION KRAME ORATE AND HOOK SEE SIO,NO, e90.t13 _L Tor' FI FLAT ITN SEC NC-C SECTION X-X GENERA! NOTES: USE CLASS "11" CONCRETE THROLhGHTU1- ARC1'IDF All CATCH BASINS CVFR 3'•8" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WrECH CL5NPLY }I•.TH STD. DRAWING 940.56. OPTIONAL CONSTRUCTION MONOLITHIC POUR,, 2' KEYWAY, CR aM BAIT NOELS. AT 12" CENTERS AS OIREGTCU BT THE ENGINEER. LJ$F FIRMS FQA THE QQNSTFRLJCTICN OF THE. BOTTOM 3L t.9. IP REINFORCED CONCRETE PIPE IS SET TM BOTTOM SLAB OF BOX, ADO TO SLAB AS SHOWN 03 STD- ND. $40-00. USE TYPE "E", "F" AHD "C" ORATES UNLESS 4THFRWERF INL7TCATFD- FOR B'-0" IN HEIGH1 CA LESS USE 6" YLALLS A!,'0 BOTTOM SLAB. OVER 9 D" TO 1& -O" IN HEIGHT USE 8" WA._LS AND BOTTOM SLAB. ADJUST QUANTTTTFS AQOC,H1TNI:I Y, CONSIHOCI (MLrH NFL CROWNS MAICH1NO. CHW,IFEA ALL EXPOSED CCRNERS DNAWLND NOT TO SCALE, FRAME GRATE AND HOOD SEE STU.NO. B40,00 STEPS - STtl, 1130. 511:1_130 T sTE NOTE J } TOP r -YaTro L Otitrra. liPoilli SECTION J-J WHERE 30" TO 3D" PIPE 13 USED i ( PLAN J 3 L TOP ELEVATION STEPS - STD. NO. SECTION M-M WHFRF . 7' TO 54' PIP!' F S I,4SFC1 h141. 66 5 L • I PLAN M 1 1=NGLISH STANDARD DRAWING FOR z N-1 N 0 1- CONCRETE SHPFT OF 2 840.02 SJ BARS "V" L ii 6 3" 2 PLAN OF TOP SLAB Y2 SECTION R-R N w J -ai V SECTION S-S rd F" DOWEL EXPANSION Jr3INTS 4' - O'r STD. B40.03 FRAML, ,�, ATf & H06❑ • \ • PLAN CURE Ahb GIJTt[2 WITH CATCH BASIN ON ST__P G8A3)CS TOP USE ON FIAT ELEV. GRADE& 29a RND UNDER EXPANSION JOINI EXPANSION JOINT :3'0.1 II DEPRESSED GUTTER LINE ELEVATION NORMAL CURD AND G(JTTi k ON LI(' T tiHADrS EXPANSION JOLNI TOP USE ON C1JIADES_OVFR Fay. EXPANSION JOINT 1'0''j1 I NORMAL GLITTER LINE OEPAE$SE❑ GLITTER LINE Max. ! 1 1 I1]" S. 0„ ELEVATION NORMAL CURB AND GLITTER ON STEEP 8RAD€5 MIHINM 0 <h$10101 AND OUANTITIE,O FOR CONCRETE CATCH MA$INIIIMED ON MIN. HEIIINT, H. WITH HQ RI$ER) - OIMF4STCNS CF 30A 1ANr, PIN- '•SUER 4IMC1'4$i'3{' CU,YD.3, CQNC- IN 941E DEDUCTIONS BE PIPE FIFE SPAN N1D-H WID''i SP(J MIN. F'LLUFL BARS-U RA%;-W RAPS W TQTSI L13S. OF SLAB BGTTOU LAB `31. Cr*; hoHR[47,- ID 13 .. G h: E F Ni-D. LENG11= NO. .ENGTI• Nil. LEJGT- t2" 3'-0" .2'-2' 2'-9" -- -_ .. .. 0.225 0.772 0.045 0.026 I t63 S -0" 2" 3'•0" 0-205 0.B2b O.023 0-v36 r0" 3. 0 2' 2 '1' 9" 0-235 a.RR7 0-032 0-749 24" H -Q' .2_-2" 3`.9' 0.22b 1 ,IjQ- ❑-DSO 0-0E5- .30" 3 .r•,' 2'.2' 3'-4.' a' 3" 1'.2" 4'.0"� 4 1' 5" 7 3'•9" 3 3'-9" '19 0.128 4.371 1.423 0.092 0.127 35" 8'-D" 2'-2" 8'-10" 4'.9' 1'-9" 4'-A" 4 1'-11". 3 3'-13" 3 3' V" a8 0.191 4.355 1.71.1 0.1132 0.'78 '12 3'-D" 2'-2" 3'-5' 3' 3" 1' S" 3' 2" 13 I` A" 2 2'-I I' 3 2'-11" 32 0.112 5.313 1./30 D.180 D.243 46" 3.-0: 2'-2" 5'-C.' .5. • 9' 2 0" a'-'' 4 2' 3" a 2'-11" a 2'-'I" 3s 0,149 0,352 7.05a 0.233 0,3'7 5.1" 5 3 '' 2' 2' 5' 7' 6 a" 2' 7" 3' - 2' -0' E 2 ' 11' 3 2' +1" q1 0.120 0,306 7.367 ❑.2-P7 0-301 ' RISER HIS .228 CUBIC YdRias Of soNCHL"r PEN FOOT HEIGH- Z 0 H¢(. O0co_ Cc LiJZLL 2~ZLLI U]h IyC-j 0 GO Z ,1-1 0 H 1- LJJ LLD LJ rl O 1-1 Cr) m RHEET 2 OF 2 840.02 1-181 STATE OF NORTH CAROLINA DEPT. OF TRANSPORTATION DIVISION OF HIGHWAYS RALEIGH, N.C. TOP OF FILL ! TOP OF FILL TOP OF FILL L r GROUND LINE r GROUND LINE r GROUND LINE �_ H �- H �- r H u1u u1 r a ru= rr t►a= in + iii - rrJLru�rr r� +�+ +rr a ++^ ++ T In ga ru COMPACT AFTER + ri► PIPE IS PLACED ► r & PRIOR TOS L 1+++� AL^►►►► ,_ 1r► si 11 fa �r^ rr r 1 r�► S`. �! 'r rrr or -►ram+► ►� in +SI COMPACT AFTER PIPE IS PLACED & PRIOR PLACEMENT OF �' .-_: � TYPE 2 .;_- PLACEMENTOF ••..;g. .� .;; FILL _ _ .... _ �+ GEOTEXTILE r FILL IX N►r1 rr�I11 +►♦♦�♦♦♦♦♦♦♦♦j♦♦♦♦�♦♦��♦ .♦.♦♦.♦� • •���� �4e.•� ♦♦♦•♦♦�♦♦♦♦♦♦♦♦�♦♦4♦i 1 ♦.♦..•♦:♦��♦♦"� F.♦ I.D. 8 YIN. �+►♦♦♦♦♦♦��♦1♦♦♦♦�♦�����♦♦� NOT LESS►.�..��.......�4•..A_��•.•4_46_4.�, I.D./6 MIN. 'm ►�11r= amiss i+r^ THAN 6" ►1arr1p1►S EARTH LESS THAN G" O.D. + 3 I.0.16 MINNOT " NOT LESS THAN 6 r1r 1N'►+1-►+ - ^ # F' 1. PER FOOT OF 'H' rr1r"'' r►I, �11 O.D. + 3' BUT NOT LESS THAN 12" NOR MORE THAN 24" 0.0. + 3' ROADWAY STANDARD DRAWING FOR METHOD OF PIPE INSTALLATION FLEXIBLE PIPE ROCK _ L `I NORMAL EARTH FOUNDATION ROCK FOUNDATION AS DIRECTED BY ENGR. UNSUITABLE MATERIAL FOUNDATION PIPE IN TRENCH TOP OF FILL TOP OF1FILL I TOP OFFILL L I- - y y l- - - - ' MIN. O.D. - H MIN. D.D. MIN. D. H MIN. 0.D. MI D. H MIN. O.D. y • li �.I '� r GROUND LINE r= GROUND LINTYPE 2fur £d• ,11-- GEOTEXTILEGROUND x1►Is►rl:rrr =1r1=►11� emu+ 1=111� ••:g ^►►or►l=lino limn' ; ^e1=rlrr++a.■ COMPACT AFTER g •': •� � t •• • • • -PIPE IS PLACED •; ► COMPACT AFTER s.�.����♦���r�♦�♦�♦��y�1�����♦�♦��� ~!�♦�!�♦�♦.♦.♦�♦••♦.♦.♦.♦�♦��♦�♦�. - & PRIOR TO s�+�����♦��� -•♦♦♦♦♦ ►�♦�♦�♦��y�� ����y����� - PIPE IS PLACED I.D.jB MIN. PLACEMENT OF /♦♦♦ ♦ ♦♦♦♦a♦ & PRIOR TO PLACEMENT OF FILL O.D. + 2' _ NOT LESS THAN 6" I.D./6 MIN. ►rr r►+_ 1►1-111Ezi u- rd Sil1i u1► FILL I.D./6 MIN. NOT LESS THAN 6" rr1yr11_ ►+ MIN. O.D. -=-►►IEvr IS. 1d alrl=u►r MIN. O.D. AS DIRECTED BY ENGINEER NOT LESS THAN 6 „ 0.D.+ 2 - NORMAL EARTH FOUNDATION ROCK FOUNDATION NOR BUT " PER FOOT OF 'H' NOT ORELESS THANT2 N 12" UNSUITABLE _ MATERIAL _ FOUNDATION PIPE ABOVE GROUND GENERAL NOTES: I.D. = THE MAXIMUM HORIZONTAL INSIDE DIAMETER DIMENSION. DO NOT OPERATE HEAVY EQUIPMENT OVER ANY PIPE CULVERT UNTIL THE PIPE CULVERT HAS BEEN PROPERLY BACKFILLED AND COVERED WITH AT LEAST 3 FEET OF APPROVED MATERIAL. 0.D. = THE MAXIMUM HORIZONTAL OUTSIDE DIAMETER DIMENSION. - - - - - SPRINGLINE OF PIPE H = THE FILL HEIGHT MEASURED VERTICALLY AT ANY POINT 7://;/!//1 ABOVE TANDCBKFILL ELOW MATERILINEAL CLASS III OR CLASS II, TYPE 1 ALONG THE PIPE FROM THE TOP OF THE PIPE TO THE TOP OF THE EMBANKMENT AT THAT POINT. APPROVED SUITABLE LOCAL MATERIAL. ® TAKE CARE TO FULLY COMPACT HAUNCH ZONE OF PIPE BACKFILL. rlErrrE rrlEr+1 UNDISTURBED EARTH MATERIAL -::: LOOSELY PLACED SELECT MATERIAL CLASS III OR CLASS II, TYPE 1 �::g . .. FOR PIPE BEDDING. LEAVE SECTION DIRECTLY BENEATH PIPE t�jj.#4P♦74r4e4 SELECT MATERIAL CLASS V OR VI FOR FOUNDATION CONDITIONING. ENCAPSULATE SHEET 1 OF 3 UNCOMPACTED AS PIPE SEATING AND BACKFILL WILL ►.♦.AMOVi WITH TYPE 2 GEOTEXTILE AS DIRECTED BY THE ENGINEER. ACCOMPLISH COMPACTION. 300.01 4'-0" 3 hr 44 X Y PLAN F -1 1„ 1'-11" L i GRATE SECTION X-X 31-101/2Rr 4'-O" i FRAME SECTION X-X %, m N 1. _W' m 1'2 , rg1 Y GRATE SECTION Y-Y 1" 1" LV u u t 1r-11" GRATE SECTION X-X FRAME SECTION X-X 214" r-L-1 2 Fr 11/2,r 0 FOR 3/8r' DIA. BOLT FRAME SECTION Y-Y NOTE: SEE STD. DWG. 840.25 FOR FRAME ANCHORAGE. o 1 Z0 co - 00 . 0 0 u)_ LLi 1-1H GO u_ 0 J 0000cc z_-� CL w 0 ROADWAY STANDARD DRAWING FOR AND NARROW SLOT SAG GRATES V} W 4 oc IL SHEET 1 OF 1 840.24 1-181 STATE OF NORTH CAROLINA DEPT. OF TRANSPORTATION DIVISION OF HIGHWAYS RALEIGH, N.C. TOP OF FILL / TOP OF FILL TOP OF FILL L- �� -_______ r GROUND LINE GROUND LINE GROUND LINE H H H en 1r at=in 1► 1' -at.- r11 ilia ■1= of M.r1►-- IriRrr.r1 I' R+rra,1T .- 1M11l in lira am win_ Jifr- I II I� ...- _- n2 mu IM 1u + r11 + ►a COMPACT AFTER COMPACT AFTER 1 ► �1 �► PIPE IS PLACED �1., r & PRIOR TO 5 ill ■ �► r,* 1 ►, 71� �► PIPE IS PLACED 1 & PRIOR TO �- • `1 OF �7r r T ! �"�'-'~� PLACEMENT OF GEOTEXTILE 1 g : .:: ► FILL Ill N ^►ri 1 „,.►ir r ....♦.r♦-♦-♦-♦-.-♦-♦♦'.♦;,,,, ++♦+♦♦+♦♦♦♦♦♦♦♦♦�♦♦ ♦♦.�•:•♦_♦ I.D./8 MIN. ►r T ♦v♦♦♦♦•+++•r;sa+•�♦w4.4 ��♦♦♦♦♦♦♦♦♦♦♦�♦♦♦♦�♦ ►♦♦♦i♦♦♦♦.♦ �_� 1 NOT LESS - .♦.♦.♦.♦.♦.♦� ♦.♦A ♦�•♦_♦_♦.A E.D. jB YIN. ►'►u= �1r►eui- THAN 6" r1 1rr�1►1 �rr1 nor r =rrr^ EARTH NOT LESS THAN 6" O.D. + 3 , I.0./6 MIN. NOT LESS THAN 6"L I+1i 11I 1r+�►1r^►+ ^ " , r PER FOOT OF H r 1►r r ►r 0.D. + 3' BUT NOT LESS THAN 12" NOR MORE THAN 24" O.D. + 3' ROADWAY STANDARD DRAWING FOR METHOD OF PIPE INSTALLATION RIGID PIPE ROCK _ L `1 NORMAL EARTH FOUNDATION ROCK FOUNDATION AS DIRECTED BY ENGR. UNSUITABLE MATERIAL FOUNDATION PIPE IN TRENCH TOP OF FILL TOP OF FILL / / TOP OF FILL ■ / l- - - H H H -- r GROUND LINE MIN. O.D. M~ p D. - GROUND LINE YIN. O.D. MIN. O.D. MIN. 0.D MIN. 0.D _ GROUND LINE - - - , - - - - - - ri. TYPE 2 GEOTEXTILE - -� - - - - .rr - f _ Ellsgiu=u1 -, Arl=rrr=1r1�u1- Eatxu1� ^rlr�rll=r "-g ':L►^r►�►►r�1MaJsZ11+ COMPACT AFTER '� :•' •II r �►♦•♦.�.♦.♦-♦���♦-♦'♦'�♦� -PIPE IS PLACED g.♦f 111 - .... I . D .16 MIN. & PRIOR TO ► ♦ ♦ .♦♦♦♦♦♦♦♦♦♦♦j♦♦�♦�♦AJUb-♦AA PLACEMENT OF ♦♦T�ii► ♦♦•♦j'= • ► ♦ ♦ .♦♦ ♦ ►♦♦)♦-♦-♦ ti'A �♦�♦�♦�♦�� NOT LESS THAN 6" I.D./6 MIN. ►rr lux in -=-r►1-a11Is 1d Siii=lit FILL I.D./6 MIN. Ert r11=_ a =►++ar is. 11d alr1r r►1 L.AS DIRECTED COMPACT AFTER O.D. + 2' _ NOT LESS THAN 6" MIN. O.D. MIN. Q.D. BY ENGINEER NOT LESS THAN 6" 0.D.+ 2+ ` PIPE IS PLACED & PRIOR TO PLACEMENT OF FILL NORMAL EARTH FOUNDATION -" ROCK FOUNDATION BUT NOR PER FOOT OF 'H' NOT LESS THAN 12" MORE THAN 24" UNSUITABLE MATERIAL FOUNDATION PIPE ABOVE GROUND GENERAL NOTES: I.D. = THE MAXIMUM HORIZONTAL INSIDE DIAMETER DIMENSION. DO NOT OPERATE HEAVY EQUIPMENT OVER ANY PIPE CULVERT UNTIL THE PIPE CULVERT HAS BEEN PROPERLY BACKFILLED AND COVERED WITH AT LEAST 3 FEET OF APPROVED MATERIAL. 0.D. = THE MAXIMUM HORIZONTAL OUTSIDE DIAMETER DIMENSION. - - - - - SPRINGLINE OF PIPE H ALONGILL THEHPIPETFROM THEDTOPROFCTHEYAT PIPEANY TO THENT TOP �� BELOWTSPRINGLINEIIIATERIAL CLASS III OR CLASS II, OF THE EMBANKMENT AT THAT POINT. - - APPROVED SUITABLE LOCAL MATERIAL ABOVE SPRINGLINE. - ® TAKE CARE TO FULLY COMPACT HAUNCH ZONE OF PIPE BACKFILL. r1EFIrrE r+rrr++ UNDISTURBED EARTH MATERIAL LOOSELY PLACED SELECT MATERIAL CLASS III OR CLASS II, TYPE 1 �:.g:-%•• - ..•• FOR PIPE BEDDING. LEAVE SECTION DIRECTLY BENEATH PIPE t;IVVF474W4 SELECT MATERIAL CLASS V OR VI FOR FOUNDATION CONDITIONING. ENCAPSULATE SHEET 2 OF 3 UNCOMPACTED AS PIPE SEATING AND BACKFILL WILL CA.Ant0A WITH TYPE 2 GEOTEXTILE AS DIRECTED BY THE ENGINEER. ACCOMPLISH COMPACTION. 300.01 l GS ' N N N DATE CITY OF MEBANE COMMENTS L. REVISIONS ' • G SERVICES I-P0 ��Qa�d �Q�xw(nOz0 ¢wOZo a¢Oo w x3mz 1- U w 1- U D_ 02 w w z c0 z w H U w O `a TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE co 02 cV CV X NOT FOR 1 \\\ CARG;',/, -4"S„ JJJJ11 i w CONSTRUCTION.) L N DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court 00 N N (NI N z O 0 x Fax: (919) 732-6676 U Pel uo I-4 Pei A ZO H x V Ci) u0 ICI O A /PROJECT NO. 18-0156 Q W 0 E- G Of 0 / DRAWING NAME: 1 8-01 56_D.dwg SHEET NO. J D-4 TOP OF DAM ELEV = 610.00' • d d • .a WEIR ELEV = 608.00' 22' 10' 2.0' DAM ELEV = 610.00' • • 4 • \ 4 4" DIAMETER ORIFICE WITH PLUG & 2" DRILLED HOLE. SEE SECTION ELEV = 606.50' 3" MIN. COVER OVER REBAR #4REBAR @16"O.C. PROVIDE STAINLESS STEEL PIPE CLAMPS & HARDWARE TO TIE "T" TO CONCRETE WEIR WALL. CONTRACTOR TO SPEC CLAMPS & HARDWARE AND PROVIDE TO ENGINEER FOR APPROVAL PERMANENT POOL ELEV 606.50' 18" MIN. EXCAVATED POOL — BELOW PERM. POOL 4 4 4 4 a d d a • •. 4 ELW=606.50' d a -III -III- I I IIIII •d a— a WET POND WEIR DETAIL — ELEVATION NTS TOP OF DAM ELEV = 610.00' WEIR ELEV = 608.00' 4" THICK CONCRETE WEIR WALL (3,000 MIN. PSI) 4" DIA., SCHED. 40 PVC TO EXTEND 12" INTO BMP W/ "T" CONNECTION WITH CAP AND EXTEND TO 12" BELOW PERM. POOL TO ENSURE WATER IS DRAWN DOWN FROM BELOW THE WATER SURFACE TO REDUCE TRASH/DEBRIS FROM CLOGGING THE ORIFICE. 4" PLUG w/ 2.0" DRILLED HOLE SHOULD BE INSTALLED ON END OF PIPE. OUTLET ELEV = 606.5' • 6" THICK CONC LINED SPILLWAY (3,000 MIN. PSI) ELEV = 606.50' #4REBAR @16"O.6.— TO EXTEND HORIZONTALLY k1• MINIMUM LENGTH EQUAL TO THE HEIGHT WET POND WEIR DETAIL — SECTION NTS OUTLET PROTECTION CLASS B RIP RAP OVER FILTER FABRIC • O 4 • In i I FOREBAY • / • 4 0 • 604- 603/ _/ SEGMENTAL BLOCK WALL (BY OTHERS) 100 YR STORM ELEV = 608.96' SLOPE STABILIZATION NOTE: INTERIOR & EXTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF CENTIPEDE SOD TO THE PERMANENT POOL AND THE TOE OF SLOPE 10 YR STORM ELEV = 608.62' III I 'I 10VEGETATIVE SHELF BOTTOM OF WALL (TOP OF VEGETATIVE SHELF) = 607.00' LINE TOP OF FOREBAY DAM W/ 12" D CLASS B LIGHT RIP RAP. PERMANENT POOL ELEV = 606.50' 10' VEGETATIVE SHELF (10:1 SLOPE) TOP OF VEGETATIVE SHELF = 607.00' SEGMENTAL BLOCK WALL (BY OTHERS) #4 REBAR @ 16" O.C. TO EXTEND HORIZONTALLY A MINIMUM LENGTH EQUAL TO THE HEIGHT (TYP) Oco TA Gn.33o N 12 *5 24.61' WETPO N D I SCALE: 1" = 20' TOP OF WALL (BOTTOM OF VEGETATIVE SHELF) = 606.00' BOTTOM ELEV = 603.00' —614- WET POND DETAIL—TYP. SECTION NTS S — WEIR OUTLET STRUCTURE BOTTOM OF VEGETATIV SHELF = 606.00' I III FOREBAY — 10' VEGETATED SHELF 10:1 SLOPE l GS • m N N N 4- DATE CITY OF MEBANE COMMENTS REVISIONS W> Y W z 0 U Q � t U W W 00¢OOZ:LI }UN a�p1—woo¢0'i0 }wUw~y��ww~ z z- W~zz�w a� Ri O p U Q Q O U W w Q o W a< } W W o z v W LLa<FQLLQ CJ ¢ WWI W a ZUO0. LL�I� O Z O� I W a zpz�Q�r�-(2 F j Q J W Liz LL J r �^ W so H0 � LL O Q w W O z W 0 CJ U U r r I U W U( z 0 Q O o () Z J Z � (n O J ~O W = m Z H U w 1- U w w z 0 z w 1- 0 w O TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER >- z GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE NOT /FOR ,„\\".\\\ CARGy -4"S„ z. �TNY A .S7\\ iJiiiini\o\ CONSTRUCTION.) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 /PROJECT NO. 18-0156 0 z O a_ w J w 0 0 c1) DRAWING NAME: J 18-0156_G. dwg SHEET NO. D-5 vil\Current Drawings \18-0156 G.dwg, D-6 SCM DETAILS-WETPOND II, 5/23/2022 5:03:43 PM, govinda.sed N:\2018\18-0156.010 - DRPB Hospitality LLC - Mebane Ho DAM ELEV = 621.00' :1 SLOP SLOPE STABILIZATION NOTE: INTERIOR & EXTERIOR SLOPES SHALL BE STABILIZED BY THE INSTALLATION OF CENTIPEDE SOD TO THE PERMANENT POOL AND THE TOE OF SLOPE 100 YR STORM ELEV = 620.03' 10 YR STORM ELEV = 619.61' 6 VEGETATIVE SHELF BOTTOM OF WALL (TOP OF VEGETATIVE SHELF) = 618.00' LINE TOP OF FOREBAY DAM W/ 12" D CLASS B LIGHT RIP RAP. PERMANENT POOL ELEV = 617.50' 6' VEGETATIVE SHELF (6:1 SLOPE) TOP OF VEGETATIVE SHELF = 618.00' SEGMENTAL BLOCK WALL (BY OTHERS) TOP OF WALL (BOTTOM OF VEGETATIVE SHELF) = 617.00' BOTTOM ELEV = 613.00' 3" MIN. COVER OVER REBAR #4REBAR@16"O.C. PROVIDE STAINLESS STEEL PIPE CLAMPS & HARDWARE TO TIE "T" TO CONCRETE WEIR WALL. CONTRACTOR TO SPEC CLAMPS & HARDWARE AND PROVIDE TO ENGINEER FOR APPROVAL TOP OF DAM ELEV = 621.00' PERMANENT POOL ELEV 617.50' 18" MIN. EXCAVATED POOL - BELOW PERM. POOL WET POND DETAIL-TYP. SECTION NTS TOP OF DAM ELEV = 621.00' WEIR ELEV = 619.50' 4" THICK CONCRETE WEIR WALL (3,000 MIN. PSI) 3" DIA., SCHED. 40 PVC TO EXTEND 12" INTO BMP W/ "T" CONNECTION WITH CAP AND EXTEND TO 12" BELOW PERM. POOL TO ENSURE WATER IS DRAWN DOWN FROM BELOW THE WATER SURFACE TO REDUCE TRASH/DEBRIS FROM CLOGGING THE ORIFICE. 3" PLUG w/ 1.5" DRILLED HOLE SHOULD BE INSTALLED ON END OF PIPE. OUTLET ELEV = 617.50' :1 SLOPE III, BOTTOM OF VEGETATIVE SHELF = 617.00' 1 III _ 3:1 SLOPE III— '-FOREBAY 6" THICK CONC LINED SPILLWAY (3,000 MIN. PSI) ELEV = 617.50' OUTLET PROTECTION CLASS B RIP RAP OVER FILTER FABRIC #4 REBAR @ 16" O.d. TO EXTEND HORIZONTALL /3k. MINIMUM LENGTH EQUAL TO THE HEIGHT WET POND WEIR DETAIL - SECTION NTS —I I 1 • • WEIR ELEV = 619.50' 22' 10' L-1 I 3EE 02) 616 617- 2.0' 10' WIDE TOP OF DAM= 621.00 621- -619- \Ill/ \Ill/ \Ill/ \Ill/ • 4 • • • 4 4 3" DIAMETER ORIFICE WITH PLUG & 1.5" DRILLED HOLE. SEE SECTION ELEV = 617.50' • • 4 4 •. a a - d ELQE V =617.50' U _1 I —III_ 1 1 1-1 1 11 1 1- WET POND WEIR DETAIL - ELEVATION NTS 11- • a od • 0 a • • • • • 0 #4 REBAR @ 16" O.C. TO EXTEND HORIZONTALLY A MINIMUM LENGTH EQUAL TO THE HEIGHT (TYP) 6'VEGETATED SHELF 6:1 SLOPE 621� WEIR OUTLET STRUCTURE WETPO N D II SCALE: 1" = 20' \ FE FOREBAY T. — 620\ \ \ \ A 1 0 m N CN CN DATE m o z o 0 z a m m m 0 r 1- 0 REVISIONS I`CO��Cr)CVr ENGINEERING SERVICES DRAWING ALTERATION W W OONox u�zQOOzcc} W p O w O O m W fn } � �=zzt9O< 0pOQQ Z _lui<HD‘112:- 5; W W �FdwQ�xyQ 2i - ate' w U¢ } o O m LLZFaOpcnco�=o�z�=�z0�¢FxXwZQ J W Z~ J f/) OVoL�2m 0Qw>> W OZ=c[ 0) W _ ❑ 0 < W Q w U U' z d p nZw-I)O > m z 1 / (PROJECT ENGINEER/ARCHITECT TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER / r o GS (GOVINDA.SEDHAY@SUMMITDE.COM) FIRST ISSUE DATE CI CD >< CONSTRUCTION.) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 00 b el 00 W en Z N M bA n '" 0 .y U 0 V 1-4 0-4 °>-1' c.) z 1-4 0.4 F^^�I I� M z� A CV Cr) ti CV Z W Z CO LLJ J CO CO LLI 0 J r 0 Z 0 w J_ W 0 0 co PROJECT NO. 18-0156 DRAWING NAME: 18-0156_G.dwg SHEET NO. D-6 1 EXCELSIOR WATTLE WATTLE DETAIL EDGE OF PAVEMENT MATTING BACK SLOPE ISOMETRIC VIEW 2'(MAX.)2' UPSLOPE STAKE ,-NATURAL GROUND MATTI NG 2 IN. MATTING 2' DOWNSLOPE STAKE CROSS SECTION VEE DITCH 2' UPSLOPE STAKE CROSS SECTION TRAPEZOIDAL DITCH NATURAL GROUND 2' DOWNSLOPE STAKE FLOW - SHEET NO. EC-20 ENGINEER IMPAULICS ENGINEER NOTES: USE MINIMUM 12 IN. DIAMETER EXCELSIOR WATTLE. USE 2 FT. WOODEN STAKES WITH A 2 IN. BY 2 IN. CROSS SECTION. ONLY INSTALL WATTLE(S) TO A HEIGHT IN DITCH SO FLOW WILL NOT WASH AROUND WATTLE AND SCOUR DITCH SLOPES AND AS DIRECTED. INSTALL A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE STAKES AT AN ANGLE TO WEDGE WATTLE TO BOTTOM OF DITCH. PROVIDE STAPLES MADE OF 0.125 IN. DIAMETER STEEL WIRE FORMED INTO A U SHAPE NOT LESS THAN 12" IN LENGTH. INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. INSTALL MATTING IN ACCORDANCE WITH SECTION 1631 OF THE STANDARD SPECIFICATIONS. INSET A INSET B TOP VIEW STANDARD METAL POSTS 2'-0" IN GROUND GALVINIZED HARDWARD WIRE EXTENDS TO TOP OF BOX t��I■■L, ° v�:-"r:(1'i�• Ark jyrrT���'�V• rd a �7 �► Coco(D...00. 604 0 Yet. _ #57 WASHED STONE PLACED TO A HEIGHT OF 12"-18" MIN. ABOVE TOP OF BOX STANDARD CATCH BASIN/YARD INLET PROTECTION NTS NOTES, 10' x 10' SQUARE WASHOUT BASIN 24" MIN, 1. INSTALL CONCRETE WASHOUT PKTAT LOCATION(S) SHOWN ON PLANS. 2. LINE PIT WITH IMPERVIOUS FABRIC OR POLYETHYLENE SHEET. ANCHOR FABRIC INTO GROUND OUTSIDE PIT AS SHOWN. 3. MAXIMUM WATER AND SEDIMENT DEPTH IS 12". PR MUST 8E EXCAVATED AND RE -LINED WHEN DEPTH OF SEDIMENT REACHES 12' OR COMBINED WATER/SEDIMENT DEPTH EXCEEDS 12" FOLLOWING WASHOUT OF CONCRETE TRUCK. 4. ALLOW WATER TO EVAPORATE COMPLETELY PRIOR TO EXCAVATING PIT. 5. WASHOUT PIT MAY BE LOCATED NO CLOSER THAN 50' TO DRAINS, INLETS. OR SURFACE WATERS. CONCRETE WASHOUT PIT H 24" MIN SLOPE 2:1 MAX r/ If NATURAL GROUND OR FILL / CUT SLOPES 11I-I1I-I1 I1 -111E111=111E111-111E111E111E111=111 I I I -1 11=11 I-111=111= BERM 24" MIN z_ II �1=III III- -=11=III=III=III- I I i lI I I I I � I I I I I�, I 1 1-1 1 1-1 11=1 1 11' " COMPACTED FILL 18" MIN DEPTH NATURAL GROUND OR `:::11=11 -11 FILL / CUT SLOPES '.'.::;11 1 1 111; II ,, -I - -� � �-1 I I-1 11-III-III-I I �1111111111111�11111�11111�11111i11111111111111111111111111i11111�11111;III-III=1I1' 111111-111=1 i 1=1 i I - - - BERM/DITCH MAINTENANCE: INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND AREA WITH NATURAL GROUND LEVEL AND STABILIZE APPROPRIATELY. FLOW 111- 1-' NATURAL GROUND OR FILL / CUT SLOPES I -I 1 I -I 1 I -I 1 I -I 1 I-I ,11111111111111111111111111111111. 18" MIN DEPTH 1111 11I-- --11111 DITCH O� 11=III-II -I SUFFICIENT TO DIRECT ALL SEDIMENT -LADEN STORMWATER INTO A SEDIMENT CONTROL DEVICE. MUST BE INSTALLED PRIOR TO CLEARING AND GRUBBING OF THE AREA (OR IN CONJUNCTION WITH THIS OPERATION IF SEDIMENT CONTROLS AND DIVERSIONS ARE INSTALLED AS EACH CRITICAL POINT IS REACHED). 1. DIVERSIONS SHOULD BE LOCATED TO MINIMIZE DAMAGES BY CONSTRUCTION OPERATIONS. 2. DIVERSIONS SHOULD BE SEEDED AND MULCHED IF THEY ARE TO REMAIN IN PLACE OVER 30 DAYS. 3. CHECK DEVICE AFTER EACH RAIN, BUT ONCE A WEEK REGARDLESS REPAIR AS NECESSARY. TEMPORARY DIVERSION BERM / DITCH NTS 5'SOD /GRASS FILTER STRIP NOTE: SEE WETLAND BMP DETAIL FOR LENGTH AND WIDTH 12" DEEP POOL MIN. 12" THICK SEE RIP RAP SIZE & DEPTH ON PLANS MIN. 6" \MIN. 12" FILTER FABRIC TO FULLY ENCOMPASS EXTENTS OF RIP RAP AND BE TOED -IN A MINIMUM OF 12" ON ALL SIDES. RIP RAP PLUNGE POOL NOT NOTES: A. WASHED STONE PAD TO BE 50'L X 25'W X 6"TH MINIMUM. IF THE ADJOINING ROADWAY IS WIDER THAN 25', THEN THE WASHED STONE SHALL BE AS WIDE AS THE ADJOINING ROADWAY. B. TURNING RADIUS SUFFICIENT TO ACCOMMODATE LARGE TRUCKS IS TO BE PROVIDED. C. ENTRANCE(S) SHOULD BE LOCATED TO PROVIDE FOR MAXIMUM UTILITY BY ALL CONSTRUCTION VEHICLES. D. MUST BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR DIRECT FLOW OF MUD ONTO STREETS. PERIODIC TOP DRESSING WITH STONE (2" THICK) WILL BE NECESSARY; KEEP SOME HANDY. E. ANY MATERIAL WHICH STILL MAKES IT ONTO THE ROAD MUST BE CLEANED UP IMMEDIATELY. NOTES: APPLICABLE AT ALL POINTS OF INGRESS AND EGRESS UNTIL SITE IS STABILIZED. FREQUENT CHECKS OF THE DEVICE AND TIMELY MAINTENANCE MUST BE PROVIDED. 2-3" COARSE AGGREGATE FILTER FABRIC UNDER STONE TEMPORARY STONE CONSTRUCTION ENTRANCE / EXIT NTS (is m) /AA/ © 1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: VVHEN USING CELLO -SEED DO NOT SEED PREPARED AREA. CELLO -SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2. BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE BLANKET IN A 6" (15cm) DEEP X 6" (15cm) WIDE TRENCH WITH APPROXIMATELY 12" (30cm) OF BLANKET EXTENDED BEYOND THE UP -SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30cm) PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30cm) APART ACROSS THE WIDTH OF THE BLANKET. 3. ROLL CENTER BLANKET IN DIRECTION OF WATER FLOW IN BOTTOM OF CHANNEL. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. VVHEN USING OPTIONAL DOT SYSTEM , STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4. PLACE CONSECUTIVE BLANKETS END OVER END (SHINGLE STYLE) WITH A 4"-6" (10cm-15cm) OVERLAP. USE A DOUBLE ROW OF STAPLES STAGGERED 4" (10cm) APART AND 4" (10cm) ON CENTER TO SECURE BLANKETS. 5. FULL LENGTH EDGE OF BLANKETS AT TOP OF SIDE SLOPES MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN A 6" (15cm) DEEP X 6" (15cm) WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. 6. ADJACENT BLANKETS MUST BE OVERLAPPED APPROXIMATELY 2"-5" (5cm-12.5cm) (DEPENDING ON BLANKET TYPE) AND STAPLED. TO ENSURE PROPER SEAM ALIGNMENT, PLACE THE EDGE OF THE OVERLAPPING BLANKET (BLANKET BEING INSTALLED ON TOP) EVEN WITH THE COLORED SEAM STITCH ON THE BLANKET BEING OVERLAPPED. 7. IN HIGH FLOW CHANNEL APPLICATIONS, A STAPLE CHECK SLOT IS RECOMMENDED AT 30 TO 40 FOOT 9m-12m INTERVALS. USE A DOUBLE ROW OF STAPLES STAGGERED 4" (10cm) APART AND 4" (10cm) ON CENTER OVER ENTIRE WIDTH OF THE CHANNEL. 8. THE TERMINAL END OF THE BLANKETS MUST BE ANCHORED WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN A 6" (15cm) DEEP X 6" (15cm) WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. NOTE: (10cm-15cm) (30 cm) ' I VA/ (15 cm) 5cm) © \\/\VA/ (15 cm) (10 cm) 5cm-12.5cm) A B C/ A B C CRITICAL POINTS A. OVERLAPS AND SEAMS B. PROJECTED WATER LINE C. CHANNEL BOTTOM/SIDE SLOPE VERTICES 14649 HIGHWAY 41 NORTH, EVANSVILLE, INDIANA 47725 USA 1-800-772-2040 CANADA 1-800-448-2040 wvw.nagreen.com * HORIZONTAL STAPLE SPACING SHOULD BE ALTERED IF NECESSARY TO ALLOW STAPLES TO SECURE THE CRITICAL POINTS ALONG THE CHANNEL SURFACE. **IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15 cm) MAY BE NECESSARY TO PROPERLY ANCHOR THE BLANKETS. MAINTENANCE: DURING THE ESTABLISHMENT PERIOD, INSPECT CHANNELS ONCE A VVEEK AND AFTER EVERY RAINFALL. REMOVE SIGNIFICANT SEDIMENT DEPOSITS THAT WOULD AFFECT VEGETATION GROVVTH. CHECK CHANNEL OUTLET AND PIPE OUTLETS FOR PIPING OR SCOUR HOLES, AND CHECK SIDE SLOPES FOR BANK STABILITY. IMMEDIATELY REPAIR ANY DAMAGE. AFTER GRASS IS ESTABLISHED, INSPECT THE CHANNELS AFTER EVERY HEAVY RAINFALL EVENT. REMOVE ALL SIGNIFICANT SEDIMENT ACCUMULATION, AND KEEP VEGETATION IN A HEALTHY, VIGOROUS CONDITION. NORTH AMERICAN GREEN SLOPE BLANKET NTS z (V • 0 0 8" 0 NOTES: 12 GAUGE 4"X4" OR 2"X4" WELDED WIRE HOOKED ONTO PERFORMED CHANNELS ON STEEL POSTS. (NO WOOD POSTS) ULTRAVIOLET RESISTANT (BLACK) MIRIFI FABRIC OR EQUIVALENT SECURED TO WIRE W/ METAL CLIPS OR WIRE AT 8" OFF CENTER. MAX. SEDIMENT STORAGE LEVEL. REMOVE SEDIMENT WHEN THIS LEVEL IS REACHED OR AS DIRECTED BY CONSERVATION INSPECTOR. - - III -AI=III-III-III-III111- 1= = =1 111=111=1 I I_ iuimui 111E111E111=111-1 1-ITI-I 11=111=111=1111-ITI-ITI=111=111=11 I_ III -I 11111a 11111111- II I -III-I 1-11 = =11111111I 11-- ' TRENCH, COVER W/ SOIL & TAMP BACKFILL. SHEET DRAINAGE (ONLY) NATURAL GRADE CARRY APPROX.12" OF FABRIC INTO TRENCH CARRY 6" OF WIRE INTO TRENCH. STEEL POSTS @ 8' O.C. MAX.. (NO WOOD POSTS) MAINTENANCE: INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPLY. REPLACE BURLAP EVERY 60 DAYS. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE.TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALSAND UNSTABLE SEDIMENT DEPOSITS AND BRING THE ARE TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. g' OC MAX �I so FENCE SEOTMEN-'g(O FLOW OF EPTT WATER 1) TOTAL DRAINAGE AREA FLOWING TO THE FENCE MAY NOT EXCEED 1 ACRE. 2) SILT FENCES SHOULD NOT BE USED AT PIPE OUTLETS OR IN AREAS OF CONCENTRATED FLOW (CREEKS, DITCHLINES, SWALES ETC.) TO INCREASE STORAGE CAPACITY AND PROLONG THE LIFE OF THE SILT FENCE, IT IS GENERALLY ADVISABLE TO DIG A SEDIMENT PIT IN FRONT OF YOUR SILT FENCE WHENEVER POSSIBLE. TEMPORARY SILT FENCE NTS ., STEEL POST WOVEN WIRE FARM SILT FENCE FABRIC MIN. 10 GA UNE WIRES FILL SLOPE 4" WIDE K B" DEEP TRENCH OVER SKIRT • ANCHOR SKIRT AS DIRECTED SY ENGINEER • SIDE VIEW e' MAX. VAAIABLE RS DIRECTED BY THE ENGINEER L LLL L L L 1 .aP����y TREE PROTECTI:ONARi'.A • ■ •••..� DO NOT E...es..•. •1ti►••••i►*••e Ti I•ER •-• •-•'.'.-•'••••-i -.4;:.4i4i►.4.s+�•4i4.ki�i�r`•� _. s r��ia.�+�i*i*i�►�+�i�i�irii�ii4.ar; •,,,,i' ►�■•► aa•� i r►�' F ���•■T��r�P s� ••i�`* a i!i�•:�'ri � •r�ai�rA.r ,►r r-r-tlT-rt r i ��r��rr. r �rr�r =Il-li-}I-II, II--•III--11-1f-iF"11-t-11�1IE=11-II-II-EI-1i1 Il-lf-11-1i-I[-II 2--III • FOR REPAIR OF SIT FENCE FAIWRES, USE No. 57 WASHED STONE. E= =1 SILT FENCE FABRIC INSTALLED TO SECOND WIRE FROM TOP NOTES: 1. ND ORANGE SILT FENCE PERMITTED. 2. USE SILT FENCE ONLY WHEN DRAINAGE AREA DOES NOT EXCEED 1/4 ACRE AND NEVER IN AREAS OF CONCENTRATED FLOW. 3. ORANGE, UV RESISTANT, H!GH-TENSIL STRENGTH, POLLY BARRICADE FABRIC MUST BE USED. 5. ENO OF SILT FENCE NEEDS TO BE TURNED UPHILL 6. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL 7. LETTERS TO BE 3" HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. 8. SIGNS SHALL BE PLACED AT 50• MAXIMUM INTERVALS. 9. PLACE A SIGN AT EACH END OF UNEAR TREE PROTECTION AND 50" ON CENTER THEREAFTER. 10. FOR TREE PROTECTION AREAS LESS THAN 200. IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. 11. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. 12. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. 13. ADDITIONAL SIGNS MAY BE REQUIRED BY TOWN OF HOLLY SPRINGS ENGINEERING DEPARTMENT BASED ON ACTUAL FIELD CONDITIONS. 14. PLACE A SIGN AT EACH END OF UNEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER, ORANGE, W RESISTANT, HIGH - TENSiL STRENGTH. POLY BARRICADE FABRIC [I YPICAL) FRONT VIEW 4• 4• 3- 4• TREE PROTECTION FENCE MIN. 12-1/2 GA. INTERMEDGTE WIRES GRADE TREE PROTECTION AREA 18" DO NOT ENTER WARNING SIGN DETAIL INLET Z I N -� z0 1-- _lnirL _ L:LY°-UI t�asw - -- - SyrFaPa-araa- - 25Y of - "r �s surface 9rP.9 / - - - SUPPORT ROPE TO WIRE TO PREVENT SAGGING FENCE AND FABRIC BURIED IN TRENCH 6"X6" TRENCH, BACKFILLED AND COMPACTED PLAN VIEW SUPPORT POST 24" INTRO BOTTOM OR SIDE COIR MESH OR SIMILAR, STAPLED OR TRENCHED INTO BOTTOM OR SIDE 2' Ii CROSS SECTION STEEL POST SECTION VIEW AT OPENING STAKE TO SUPPORT WIRE NOTES: 1. BAFFLE MATERIAL SHOULD BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR SILT FENCE. 2. MOST OF THE SEDIMENT WILL ACCUMULATE IN THE 1ST BAY, WHICH SHOULD BE READILY ACCESSIBLE FOR MAINTENANCE. 3. PROVIDE 3 BAFFLES (USE TWO IF LESS THAN 20 FEET IN LENGTH). PROVIDE 5 BAFFLES FOR DRAINAGE AREAS GREATER THAN 10 ACRES. 4. BAFFLE SHALL BE 700 G/M2 COIR EROSION BLANKET. 5. TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERMS 6. INSPECT BAFFLES FOR REPAIR ONCE A WEEK AND AFTER EACH RAINFALL INFLOW STRUCTURE -24" MIN TARP PROTECTION. EMERGENCY SPILLWAY BAFFLES INFLOW STRUCTURE PLAN VIEW BAFFLES (STD) 1' MIN FREEBOARD SKIMMER DEWATERING ZONE INLET SHALL BE PROTECTED (AS NEEDED) FROM EROSION WITH RIPRAP, TARP, MATTING OR EQUIVALENT. CROSS SECTION 16" MAX FLOW DEPTH 10' MINA WEIR LENGTH SECTION THRU WEIR TOP OF DAM EMERGENCY SPILLWAY ELEVATION CMP OUTLET PIPE r J TOP OF DAM L DITCH AND BURY TARP EDGE (MIN. 12") DISSIPATER PAD (-RIP RAP NOTES: 1. BASIN SHOULD BE CLEANED OUT WHEN CAPACITY REACHES AN ELEVATION REPRESENTING THAT THE BASIN IS HALF -FULL. 2. THE TARP USED TO PROTECT THE WEIR SHALL BE THE WIDTH SPECIFIED. THE LENGTH OF THE TARP SHALL BE ACCORDING TO AVAILABLE SUPPLY. IF MULTIPLE TARPS ARE TO BE USED, THEN TARPS SHALL BE OVERLAPPED AT LEAST 12". THE UPSTREAM 12" TARP SHALL OVERLAP THE DOWNSTREAM TARP. THE TARP SHALL BE 50 MIL. HEAVY DUTY SILVER TARPAULINS OR EQUIVALENT FOR U.V. RESISTANCE. 3. PROVIDE A MINIMUM OF THREE POROUS BAFFLES TO EVENLY DISTRIBUTE FLOW ACROSS THE BASIN, REDUCING TURBULENCE. 4. BAFFLE MATERIAL MUST BE SECURED AT THE BOTTOM AND SIDES USING STAPLES OR BY TRENCHING AS FOR A SILT FENCE. 5. MOST OF THE SEDIMENT WILL ACCUMULATE IN THE FIRST BAY, SO THIS SHOULD BE READILY AVAILABLE FOR MAINTENANCE. 6. DURING THE CONSTRUCTION PHASE OF THE PROJECT, PERMANENT STORMWATER RISER SHALL ONLY DEWATER FROM THE TOP OF PIPE. 7. POND SHALL NOT BE CONVERTED FOR STORMWATER USE UNTIL APPROVED BY ENVIRONMENTAL ENGINEER. WATER ENTRY UNIT WITH TRASH SCREEN ORIFICE OPENING INSIDE THE HORIZONTAL TUBE WITH A CONSTANT HYDRAULIC HEAD SCHEDULE 40 PVC PIPE FLOAT PVC VENT PIPE (BARREL OR ARM) FLEXIBLE HOSE TOP VIEW WATER ENTRY UNIT END VIEW GENERAL NOTES: 1. PROPER DESIGN MUST BE COMPLETED TO MINIMIZE PIPING AROUND DISCHARGE PIPE. 2. PROPER ORIFICE OPENING MUST BE SELECTED TO ENSURE POND DRAINS IN CORRECT AMOUNT OF TIME. MODIFICATIONS MAY BE REQUIRED IF FIELD CONDITIONS WARRANT A CHANGE. 3. EMBANKMENT MUST BE COMPACTED TO DESIGN SPECIFICATIONS. 4. EMERGENCY SPILLWAY MUST BE CORRECTLY SIZED AND EROSION PROTECTION INSTALLED. 5. EROSION PROTECTION MUST BE INSTALLED ALONG THE EMBANKMENT AND AT THE DISCHARGE END OF THE PIPE. 6. INSPECT SYSTEM REGULARLY TO ENSURE IT IS FUNCTIONING IN A CORRECT MANNER. 7. EIGHT SIZES OF SKIMMERS ARE AVAILABLE, REFER TO THE FLOW SHEET, CUT SHEET, AND INSTRUCTIONS ON WEB SITE FOR EACH SIZE. 111=11 III=1 III- _I POTENTIAL FOR PIPING CAN OCCUR. PROPER DESIGN TO MINIMIZE DISCHARGE AROUND PIPE MUST OCCUR. DISCHARGE PIPE SCHEDULE 40 EARTHEN EMBANKMENT EMERGENCY SPILLWAY SCHEDULE 40 PVC PIPE (BARREL OR ARM) FLEXIBLE HOSE I 1=1 I 1 -111E111E111E111-11 PVC VENT PIPE FLOAT L = 1.4 x DEPTH TO THE OVERFLOW MINIMUM LENGTH APPUES 11=111=1M= USE SUPPORT ROPE OR HOG WIRE TO PREVENT SAGGING STEEL POSTS 4' O.C. MATERIAL SIMILAR TO 700 G/m2 COIR EROSION BLANKET OR COIR MESH FOLDED OVER TO REDUCE PORE SIZE - MUST BE STAPLED OR TRENCHED TOP OF FABRIC SHOULD BE 6" HIGHER THAN MAIN SPILLWAY AND 2" LOWER THAN TOP OF THE DAM STEEL POSTS 4' 0.C. POROUS BAFFLES AND INSTALLATION N TS 24" MIN MATERIAL SHOULD BE EXTENDED INTO THE SIDES OF THE EXCAVATION SO THAT NO WATER CAN FLOW AROUND THE EDGES OF THE BAFFLE l GS . • } m CV CV CV d- DATE CITY OF MEBANE COMMENTS REVISIONS �COLO�MNNJ G SERVICES DRAWING ALTERATION i H U w H 2 O w w z C. z w 1- O w O , 0_ TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER J >- z GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE LL CV 0 CV 7.1 NOT FOR \\\�i1111111///// CARG, 4z CONSTRUCTION.) DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 7- U pel uo Pei A 0 0 OemN N ti N z w z CO w 0 J m w 0 /PROJECT NO. f J 0 0 Z 0 U Z 0 0�/ L.1_ w 18-0156 DRAWING NAME: 18-01 56_D.dwg 1 SKIMMER BASIN NTS SIDE VIEW (NO SCALE) MAINTAIN DEPRESSION TO MINIMIZE CHANCE OF SKIMMER BECOMING STUCK SKIMMER NTS SHEET NO. 1 NORTH AMERICAN GREEN 12" (30 cm) 1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: WHEN USING CELLO -SEED DO NOT SEED PREPARED AREA. CELLO -SEED MUST BE INSTALLED WITH PAPER SIDE DOWN. 2. BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE BLANKET IN A 6" (15cm) DEEP X 6" (15cm) WIDE TRENCH WITH APPROXIMATELY 12" (30cm) OF BLANKET EXTENDED BEYOND THE UP -SLOPE PORTION OF THE TRENCH. ANCHOR THE BLANKET WITH A ROW OF STAPLES/STAKES APPROXIMATELY 12" (30cm) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30cm) PORTION OF BLANKET BACK OVER SEED AND COMPACTED SOIL. SECURE BLANKET OVER COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30cm) APART ACROSS THE WIDTH OF THE BLANKET. 3. ROLL THE BLANKETS (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. BLANKETS WILL UNROLL WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL BLANKETS MUST BE SECURELY FASTENED TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE STAPLE PATTERN GUIDE. WHEN USING OPTIONAL DOT SYSTEM , STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 4. THE EDGES OF PARALLEL BLANKETS MUST BE STAPLED WITH APPROXIMATELY 2"-5" (5cm-12.5cm) OVERLAP DEPENDING ON BLANKET TYPE. TO ENSURE PROPER SEAM ALIGNMENT, PLACE THE EDGE OF THE OVERLAPPING BLANKET (BLANKET BEING INSTALLED ON TOP) EVEN WITH THE COLORED SEAM STITCH ON THE PREVIOUSLY INSTALLED BLANKET. 5. CONSECUTIVE BLANKETS SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE STYLE) WITH AN APPROXIMATE 3" (7.5cm) OVERLAP. STAPLE THROUGH OVERLAPPED AREA, APPROXIMATELY 12" (30cm) APART ACROSS ENTIRE BLANKET WIDTH. NOTE: *IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE OR STAKE LENGTHS GREATER THAN 6" (15cm) MAY BE NECESSARY TO PROPERLY SECURE THE BLANKETS. 14649 HIGHWAY41 NORTH, EVANSVILLE, INDIANA47725 USA 1-800-772-2040 CANADA 1-800-448-2040 www.nagreen.com TYPICAL SLOPE BLANKET INSTALLATION PERMANENT SEEDING IN NORTH CAROLINA (TABLE 6.11L) SEEDING MIXTURE SPECIES TALL FESCUE SERICEA LESPEDEZA KOBE LESPEDEZA RATE (LB/ACRE) 250 20 10 50 SEEDING NOTES 1. AFTER AUGUST 15 USE UNSCARIFIED SERICEA SEED. 2. WHERE PERIODIC MOWING IS PLANNED OR A NEAR APPEARANCE IS DESIRED, OMIT SERICEA AND INCREASE KOBE LESPEZEDA TO 40 LB/ACRE. 3. TO EXTEND SPRING SEEDING DATES INTO JUNE, ADD 15LB/ACRE HULLED BERMUDAGRASS. HOWEVER, AFTER MID-APRIL IT IS PREFERABLE TO SEED TEMPORARY COVER. NURSE PLANTS BETWEEN MAY 1 AND AUGUST 15, ADD 10 LB/ACRE GERMAN MILLET OR 15LB/ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUGUST 15 ADD 40 LB/ACRE RYE (GRAIN). SEEDING DATES FALL: LATE WINTER: BEST POSSIBLE AUGUST 25 - SEPTEMBER 15 AUGUST 20 - OCTOBER 25 FUBRUARY 15 - MARCH 21 FEBRUARY 1 - APRIL 15 FALL IS BEST FOR ALL FESCUE AND LATE WINTER FOR LESPEDEZAS. OVER SEEDING OF KOBE LESPEZEDA OVER FALL -SEEDED TALL FESCUE IS VERY EFFECTIVE. SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 4,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR ROVING OR BY CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MAY BE MOWED ONCE OR TWICE AYEAR, BUT MOWING IS NOT NECESSARY. RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. SEEDING SCHEDULE 1.) CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2.) RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3.) REMOVE ALL LOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4.) APPLY AGRICULTURAL LIME, FERTILIZER, AND UNIFORMLY AND MIX WITH SOIL (SEE BELOW*). 5.) CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 6.) SEED ON A FRESHLY PREPARED SEEDBED AND SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK 7.) MULCH IMMEDIATELY AFTER SEEDING AND 8.) INSPECT ALL SEEDED AREAS AND MAKE NECESSARY RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. STAND SHOULD BE OVER 60% DAMAGED, REESTABLISH ORIGINAL LIME, FERTILIZER AND SEEDING RATES. 9.) CONSULT CONSERVATION INSPECTOR ON MAINTENANCE AND FERTILIZATION AFTER PERMANENT COVER IS APPLY: AGRICULTURAL LIMESTONE - 2 TONS/ ACRES (3 TONS/ACRE IN CLAY SOILS) FERTILIZER - 1,000 Ibs. / ACRE-10-10-10 SUPERPHOSPHATE- 500 Ibs> / ACRE -20% ANALYSIS MLCH -2 TONS /ACRE (5000 LBS/AC FOR STEEP SLOPES) - SMALL GRAIN STRAW ANOTHER - ASPHALT EMULSION @ 300 GALS./ ACRE SEEDBED PREPARATION MAINTENANCE: NEW SEEDLINGS SHOULD BE INSPECTED FREQUENTLY AND MAINTENANCE PERFORMED AS NEEDED. IF RILLS ANG GULLIES DEVELOP, THEY MUST BE FILLED, RE -SEEDED, AND MULCHED AS SOON AS POSSIBLE. DIVERSIONS MAY BE NEEDED UNTIL NEW PLANTS TAKE HOLD. DAMAGE TO VEGETATION FROM DISEASE, INSECTS, TRAFFIC, ETC., CAN OCCUR AT ANY TIME.HERBICIDES AND REGULAR MOWING MAY BE NEEDED TO CONTROL WEEDS. DUST AND SPRAYS MAY BE NEEDED TO CONTROL INSECTS. WEEK OR DAMAGED SPOTS MUST BE RELIMED, FERTILIZED, MULCHED, AND RESEEDED AS PROMPTLY AS POSSIBLE. MAINTENANCE OF EROSION AND SEDIMENT CONTROL MEASURES MAINTAIN ALL EROSION AND SEDIMENT CONTROL MEASURES PER THE REQUIREMENTS OF THE PERMIT AND THE NORTH CAROLINA SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. AT A MINIMUM, THE FOLLOWING MAINTENANCE IS REQUIRED: 1. CONSTRUCTION ENTRANCE (a. WASH AND RE -WORK STONE AND/OR PLACE ADDITIONAL STONE AS REQUIRED PREVENTING TRACKING OF MUD ONTO THE ROADWAYS. (b. CLEAN OUT THE SEDIMENT -TRAPPING DEVICE FOR THE WASH RACK. (c. REMOVE ALL MATERIALS SPILLED, DROPPED, WASHED OR OTHERWISE TRACKED ONTO ROADWAYS OR INTO STORM SEWERS IMMEDIATELY. DO NOT USE WATER TRUCKS TO WASH THE ROADWAYS. (d. MAINTENANCE AND REPAIRS SHOULD COMPLY WITH THE REQUIREMENTS OF STANDARD AND SPECIFICATION 6.06 OF THE NORTH CAROLINA SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 2. SILT FENCE (a. INSPECT IMMEDIATELY FOLLOWING EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. (b. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. GIVE SPECIAL ATTENTION TO DAMAGE RESULTING FROM END -RUNS AND UNDERCUTTING. (c. REPLACE FABRIC AND/OR WIRE THAT IS DECOMPOSING OR IS OTHERWISE INEFFECTIVE. (d. CLEAN OUT ACCUMULATED SEDIMENT FOLLOWING EVERY STORM EVENT. DO NOT ALLOW SEDIMENT TO ACCUMULATE HIGHER THAN ONE-HALF THE HEIGHT OF THE BARRIER. (e. MAINTENANCE AND REPAIRS SHOULD COMPLY WITH THE REQUIREMENTS OF STANDARD AND SPECIFICATION 6.62 OF THE NORTH CAROLINA SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 3. SILT FENCE OUTLET (a. INSPECT SILT FENCE OUTLET FOLLOWING EVERY STORM EVENT. RE -LAY ROCK AS NECESSARY TO PREVENT CONCENTRATED FLOW FROM RUNNING ACROSS THE OUTLET PROTECTION. 4. STORM WATER OUTLET/INLET (a. INSPECT OUTLET/INLET PROTECTION FOLLOWING EVERY STORM EVENT. RE -LAY RIPRAP AS NECESSARY TO PREVENT CONCENTRATED FLOW FROM RUNNING ACROSS THE OUTLET PROTECTION. (b. MAINTENANCE AND REPAIRS SHOULD COMPLY WITH THE REQUIREMENTS OF STANDARD AND SPECIFICATION 6.51 OF THE NORTH CAROLINA SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 5. SKIMMER SEDIMENT BASIN (a. SKIMMER SEDIMENT BASINS SHOULD BE INSPECTED AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL EVENT. (b. SEDIMENT SHOULD BE REMOVED AND RESTORED TO ITS' ORIGINAL DESIGN DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE FIRST BAFFLE. (c. THE SKIMMER SHOULD BE INSPECTED FOR CLOGS AND REPAIRED APPROPRIATELY. (d. MAINTENANCE AND REPAIRS SHOULD COMPLY WITH THE REQUIREMENTS OF STANDARD AND SPECIFICATION 6.64 OF THE NORTH CAROLINA SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 6. POROUS BAFFLES (a. POROUS BAFFLES SHOULD BE INSPECTED DURING THE SKIMMER SEDIMENT BASIN INSPECTION AND REPAIRED IF THEY ARE DAMAGED AND RE -ANCHORED AS NECESSARY. (b. MAINTENANCE AND REPAIRS SHOULD COMPLY WITH THE REQUIREMENTS OF STANDARD AND SPECIFICATION 6.65 OF THE NORTH CAROLINA SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 7. TEMPORARY DIVERSION DITCH WITH MATTING (a. DIVERSION DITCH, EROSION CONTROL MATTING, AND WATTLE CHECKS SHOULD BE INSPECTED ONCE A WEEK AND AFTER EVERY RAINFALL. (b. REMOVE ALL SIGNIFICANT SEDIMENT ACCUMULATIONS WITHIN DITCH. (c. MAINTENANCE AND REPAIRS SHOULD COMPLY WITH THE REQUIREMENTS OF STANDARD AND SPECIFICATION 6.17 AND 6.30 OF THE NORTH CAROLINA SEDIMENT CONTROL PLANNING AND DESIGN MANUAL 8. WATTLE CHECKS (a. THE UPSTREAM SIDE OF THE WATTLE SHOULD BE MAINTAINED TO ALLOW THE WATER TO FLOW THROUGH, REDUCE VELOCITY, DISTRIBUTE FLOCCULANT AND ALLOW SEDIMENTATION TO OCCUR. (b. IF THE NATURAL FIBERS OF THE WATTLE BECOME TOO SATURATED WITH DEBRIS, SEDIMENT, ETC., AND REMOVAL OF THESE ITEMS IS NOT POSSIBLE, WATTLES SHOULD BE REPLACED. (c. STAKES SHOULD BE USED TO ANCHOR THE WATTLE ADEQUATELY TO THE GROUND TO PREVENT SCOURING AND WASHOUT DURING STORM EVENTS. (d. THE EXCELSIOR PAD BENEATH THE WATTLES IS CRITICAL TO THE PROPER FUNCTIONING OF THE WATTLES. 9. NAG - SC150 MATTING (a. REPAIR EROSION AND/OR UNDERMINING AT THE TOP OF THE SLOPE. (b. REPAIR UNDERMINING BENEATH MATTING. PULL BACK THE MATTING, FILL AND COMPACT ERODED AREA, RESEED AND THEN SECURE MATTING FIRMLY. (c. REPOSITION OR REPLACE MATTING THAT HAS MOVED ALONG THE SLOPE OR CHANNEL AND SECURE FIRMLY. REPLACE DAMAGED MATTING. EROSION CONTROL & MAINTENANCE PLAN NOTES: 1. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE STANDARDS, SPECIFICATIONS AND DETAILS OF THE LATEST EDITION OF THE NC EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. THE APPLICANT HAS THE RESPONSIBILITY TO CONTACT, VERIFY AND ADHERE TO ALL NCDEQ SPECIFICATIONS AND CHECKLIST REQUIREMENTS OF THE STATE, WHICH CAN BE REVIEWED AT THE NCDEQ WEBSITE. HTTPS://DEQ. NC. GOV/ABOUT/DIVISIONS/ ENERGY-MINERAL-LAND-RESOURCES/EROSION-SEDIMENT-CONTROL/ FORMS 2. RETAIN FLOATABLE WIND BLOWN MATERIALS ON SITE BY STORING ALL TRASH AND BUILDING MATERIAL WASTE IN ENCLOSURES UNTIL DISPOSAL AT OFF -SITE FACILITIES. CHECK ADJACENT AREAS DAILY AND PICK UP CONSTRUCTION WASTE MATERIALS AND DEBRIS THAT HAVE BLOWN OR WASHED OFF SITE. 3. PERMANENTLY STABILIZE ALL SURFACE AREAS WITHIN AND ADJACENT TO THIS SITE THAT ARE DISTURBED BY VEHICLES, GRADING AND OTHER CONSTRUCTION FOR THE PROPOSED FACILITY. STABILIZATION IS OBTAINED WHEN THE DISTURBED SURFACE IS COVERED WITH STRUCTURES, PAVING AND OR PERENNIAL VEGETATION HAVING A UNIFORM COVERAGE DENSITY OF AT LEAST 70%. STABILIZATION OF ALL DISTURBED AREAS IS REQUIRED BEFORE TERMINATION OF MAINTENANCE AND REMOVAL OF EROSION CONTROL MEASURES. 4. CONTRACTOR SHALL INSPECT SEDIMENT CONTROL MEASURES AT LEAST ONCE EVERY 7 DAYS AND WITHIN 24 HOURS AFTER A STORM EVENT OF 1" OR GREATER. DAMAGED MEASURES THAT PROVE TO BE INEFFECTIVE SHALL BE REPLACED WITH MORE EFFECTIVE MEASURES OR ADDITIONAL MEASURES WITHIN SEVEN DAYS. REPEATED FAILURE OF A CONTROL MEASURE REQUIRES INSTALLATION OF A MORE SUITABLE DEVICE TO PREVENT DISCHARGED OF SEDIMENT FROM THE CONSTRUCTION SITE. 5. INSTALLATION OF ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED BY THE EROSION CONTROL INSPECTOR. CONTRACTOR TO VERIFY REQUIREMENTS PRIOR TO BEGINNING ANY WORK ON PROJECT SITE. 6. CARE SHALL BE TAKEN TO MINIMIZE THE ENCROACHMENT OF SEDIMENT INTO ALL STORM DRAIN APPURTENANCES, PUBLIC STREETS, AND ONTO PRIVATE PROPERTY UNTIL IMPERVIOUS MATERIAL (ROAD/PARKING AREA SURFACE) IS APPLIED OR UNTIL PROPOSED LANDSCAPE HAS BEEN ESTABLISHED. 7. ALL AREAS NOT SHOWN AS PAVEMENT OR BUILDING UNDER FINAL CONSTRUCTION SHALL BE TEMPORARILY AND PERMANENTLY SEEDED AS REQUIRED. 8. ALL GRASS SLOPES WHICH EXCEED 3:1 (H:V) AND/OR ARE ADJACENT TO EXISTING JURISDICTIONAL WETLANDS SHALL UTILIZE NORTH AMERICAN GREEN (NAG) CONSTRUCTION PRODUCTS TURF REINFORCEMENT MATS SC150 OR APPROVED EQUAL UNLESS OTHERWISE SPECIFIED ON PLANS. MATS SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND STANDARDS. CONTRACTOR SHALL COORDINATE INSTALLATION INSPECTION WITH MANUFACTURER. DAM EMBANKMENT CONSTRUCTION STANDARDS: 1. CONTROLLED FILL, AS SPECIFIED BY THE GEOTECHNICAL ENGINEER, IN THE DAM EMBANKMENT SHALL BE PLACED IN 6-INCH LOOSE LAYERS (3-INCH LOOSE LAYERS WITHIN 3-FEET OF EITHER SIDE OF THE PRINCIPAL STRUCTURE) AND SHALL BE COMPACTED TO A DENSITY OF NO LESS THAN 95% OF THE STANDARD PROCTOR MAXIMUM DENSITY AT A MOISTURE CONTENT OF + OR - TWO PERCENTAGE POINTS OF THE OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM D698. 2. ALL VISIBLE ORGANIC DEBRIS SUCH AS ROOTS AND LIMBS SHALL BE REMOVED FROM THE FILL MATERIAL PRIOR TO COMPACTION TO THE REQUIRED DENSITY. SOILS WITH ORGANIC MATTER CONTENT EXCEEDING 5% BY WEIGHT SHALL NOT BE USED. STONES GREATER THAN 3-INCH (IN ANY DIRECTION) SHALL BE REMOVED FROM THE FILL PRIOR TO COMPACTION. 3. FILL MATERIAL PLACED AT DENSITIES LOWER THAN SPECIFIED MINIMUM DENSITIES OR AT MOISTURE CONTENTS OUTSIDE THE SPECIFIED RANGES OR OTHERWISE NOT CONFORMING TO SPECIFIED REQUIREMENTS SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE MATERIALS. 4. ANY FILL LAYER THAT IS SMOOTH DRUM ROLLED TO REDUCE MOISTURE PENETRATION DURING A STORM EVENT SHALL BE PROPERLY SCARIFIED PRIOR TO THE PLACEMENT OF THE NEXT SOIL LIFT. 5. SURFACE WATER AND STREAM FLOW SHALL BE CONTINUOUSLY CONTROLLED THROUGHOUT CONSTRUCTION AND THE PLACEMENT OF CONTROLLED FILL. 6. FOUNDATION AREAS MAY REQUIRE UNDERCUTTING OF COMPRESSIBLE AND/OR UNSUITABLE SOILS IN ADDITION TO THAT INDICATED ON THE PLANS. ALL SUCH UNDERCUTTING SHALL BE PERFORMED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER AND SHALL BE MONITORED AND DOCUMENTED. IN NO CASE SHALL THERE BE AN ATTEMPT TO STABILIZE ANY PORTIONS OF THE FOUNDATION SOILS WITH CRUSHED STONE. 7. TREATMENT OF SEEPAGE AREAS, SUBGRADE PREPARATION, FOUNDATION DEWATERING AND ROCK FOUNDATION PREPARATION (I.E., TREATMENT WITH SLUSH GROUTING, DENTAL CONCRETE, ETC.) MAY BE REQUIRED AT THE DISCRETION OF THE GEOTECHNICAL ENGINEER. ALL SUCH ACTIVITIES SHALL BE CLOSELY MONITORED AND DOCUMENTED BY THE GEOTECHNICAL ENGINEER. 8. FILL ADJACENT TO THE PRINCIPAL SPILLWAY SHALL BE PLACED SO THAT LIFTS ARE AT THE SAME LEVEL ON BOTH SIDES OF THE STRUCTURES. 9. EARTHWORK COMPACTION WITHIN 3-FEET OF ANY STRUCTURES SHALL BE ACCOMPLISHED BY MEANS OF HAND TAMPERS, MANUALLY DIRECTED POWER TAMPERS OR PLATE COMPACTORS OR MINIATURE SELF-PROPELLED ROLLERS. 10. COMPACTION BY MEANS OF DROP WEIGHTS FROM A CRANE OR HOIST SHALL NOT BE PERMITTED. 11. HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO PASS OVER CAST -IN -PLACE STRUCTURES UNTIL ADEQUATE CURING TIME HAS ELAPSED. 12. TO RE-ESTABLISH VEGETATION AFTER CONSTRUCTION, A 2 TO 3 INCH LAYER OF TOPSOIL SHALL BE PLACED ON THE DISTURBED EMBANKMENT SURFACE AND THE AREA SEEDED AND SODDED OR HYDROSEEDED. CONSTRUCTION ENTRANCE NOTES: 1. CONSTRUCTION ENTRANCE SHALL BE 25' MINIMUM WIDTH AND 50' MINIMUM LENGTH AND 6" MINIMUM THICKNESS OF STONE (3"-4") COARSE AGGREGATE WITH GEOTEXTILE UNDERLINER. REFER TO THE LOCAL GOVERNMENT OR STATE FOR ANY ADDITIONAL REQUIREMENTS. 2. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH 3"-4" STONE, AS CONDITIONS DEMAND, AND REPAIR AND/OR CLEAN OUT OF ANY STRUCTURE USED TO TRAP SEDIMENT. ALL MATERIALS SPILLED, DROPPED, WASHED, OR TRACKED FROM VEHICLES OR SITE ONTO ROADWAYS OR INTO STORM DRAINS MUST BE REMOVED IMMEDIATELY. 3. WHEELS MUST BE CLEANED TO REMOVE MUD PRIOR TO ENTRANCE ONTO PUBLIC RIGHT-OF-WAY. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT TRAP OR SEDIMENT BASIN LOCATED PER THE LOCAL GOVERNMENT OR STATE REQUIREMENTS. 4. MAINTAIN CONSTRUCTION ENTRANCE THROUGHOUT ALL PHASES OF CONSTRUCTION. WHEN SITE IS READY FOR FINAL INSTALLATION OF PAVEMENT SECTION AS NOTED ON THE APPROVED PLANS, CONTACT THE EROSION CONTROL INSPECTOR FOR APPROVAL PRIOR TO REMOVING THE CONSTRUCTION ENTRANCE. DECOMMISSIONING A SEDIMENT BASIN: 1. CALL E&C INSPECTOR FOR ON -SITE DETERMINATION/MEETING WHEN REQUESTING TO DECOMMISSION/PHASE OUT A TEMPORARY SEDIMENT BASIN. 2. DETERMINATION CAN ONLY BE MADE BY THE LOCAL PROGRAM EROSION CONTROL SPECIALIST AND/OR HIS OR HER SUPERVISOR. 3. ONCE IT HAS BEEN AGREED THAT THE TEMPORARY SEDIMENT BASIN CAN COME OUT IT MUST BE MARKED AND INITIALED BY THE INSPECTOR ON THE APPROVED SET OF EROSION CONTROL PLANS. 4. INSTALL SILT FENCE OR OTHER TEMPORARY EROSION CONTROL MEASURES AS NEEDED PRIOR TO THE REMOVAL OF THE BASIN. 5. IF SEDIMENT BASIN HAS WATER IN IT, THE WATER MUST BE PUMPED OUT FROM THE SURFACE INTO A FILTER BAG ON A LEVEL AREA FREE OF DEBRIS OR ANOTHER APPROVED METHOD AT NON -EROSIVE PROPERTIES. 6. REMOVE SKIMMER AND PLUG ANY HOLES IN THE RISER (IF APPLICABLE), REMOVE ALL BAFFLE MATERIALS. 7. IF THERE IS A LOT OF SEDIMENT/SILT IN THE BOTTOM OF THE BASIN AND MUST BE HAULED OFF, MIX WITH DRY MATERIAL OR SET ASIDE TO DRY THEN HAUL OFF. 8. FILL OR CONVERT BASIN AS TO THE APPROVED ELEVATION OR PRODUCT ON THE APPROVED PLANS. 9. AFTER FINAL GRADING HAS BEEN COMPLETED AREA MUST BE STABILIZED WITH LIME, SEED, FERTILIZER, STRAW AND TACK. 9.1. SEEDING MUST BE DONE WITHIN 7 DAYS OF GRADING ON SLOPES STEEPER THAN 3:1 AND 12 DAYS FOR ALL OTHER. STABILIZATION TIMEFRAMES Site Area Description Stabilization Timeframe Exceptions Perimeter dikes, swales, ditches and slopes 7 days None High Quality Water (HQW) Zones 7 days None Slopes steeper than 3:1 7 days If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed Slopes 3:1 or flatter 14 days 7 days for slopes greater than 50' in length All other areas with slopes flatter than 4:1 14 days None, except for perimeters and HQW Zones SEEDING NOTES 1. TILL ALL AREAS THAT ARE TO BE SEEDED TO A 6" DEPTH. REMOVE ALL LOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS, LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 2. APPLY AGRICULTURAL LIME & FERTILIZER. UNIFORMLY MIX WITH SOIL (SEE NOTE BELOW*). 3. SEED FRESHLY PREPARED SEEDBED SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK . 4. MULCH IMMEDIATELY AFTER SEEDING. 5. INSPECT ALL SEEDED AREAS AND PERFORM NECESSARY RESEEDING WITHIN THE SAME PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 60% DAMAGED, REESTABLISH ORIGINAL LIME, FERTILIZER AND SEEDING RATES. 6. CONTINUE MAINTENANCE AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. APPLY: AGRICULTURAL LIMESTONE - 2 TONS/ ACRES (3 TONS/ ACRE IN CLAY SOILS) FERTILIZER - 1,000 lbs. / ACRE-10-10-10 SUPERPHOSPHATE- 500 Ibs> / ACRE -20% ANALYSIS MLCH -2 TONS / ACRE (5000 LBS/AC FOR STEEP SLOPES) - SMALL GRAIN STRAW ANOTHER - ASPHALT EMULSION @ 300 GALS./ ACRE SEEDBED PREPARATION MAINTENANCE: NEW SEEDLINGS SHOULD BE INSPECTED FREQUENTLY AND MAINTENANCE PERFORMED AS NEEDED. IF RILLS ANG GULLIES DEVELOP, THEY MUST BE FILLED, RE -SEEDED, AND MULCHED AS SOON AS POSSIBLE. DIVERSIONS MAY BE NEEDED UNTIL NEW PLANTS TAKE HOLD. DAMAGE TO VEGETATION FROM DISEASE, INSECTS, TRAFFIC, ETC., CAN OCCUR AT ANY TIME.HERBICIDES AND REGULAR MOWING MAY BE NEEDED TO CONTROL WEEDS. DUST AND SPRAYS MAY BE NEEDED TO CONTROL INSECTS. WEEK OR DAMAGED SPOTS MUST BE RELIMED, FERTILIZED, MULCHED, AND RESEEDED AS PROMPTLY AS POSSIBLE. LATE WINTER & EARLY SPRING SUMMER FALL LATE WINTER & EARLY SPRING SUMMER FALL TEMPORARY SEEDING OF SITE SEEDING MIXTURE SPECIES RATE (LB/ACRE) RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 50 GERMAN MILLET 40 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IN THE PIEDMONT AND MOUNTAINS, A SMALL -STEMMED SUNDAGRASS RYE (GRAIN) IS NOT TO EXTEND BEYOND JUNE. MAY BE SUBSTITUED AT A RATE OF 50 LB/ACRE. SEEDING DATES: 120 MOUNTAINS - ABOVE 2500 ft: FEB. 15 - MAY 15 BELOW 2500 ft: FEB. 1 - MAY 1 PIEDMONT - JAN. 1 - MAY 1 COASTAL PLAIN - DEC. 1 - APR. 15 MOUNTAINS - MAY 15 - AUG. 15 PIEDMONT - MAY 1 - AUG. 15 COASTAL PLAIN - APR. 15 - AUG. 15 MOUNTAINS - AUG. 15 - DEC. 15 COASTAL PLAIN AND PIEDMONT - AUG. 15 - DEC. 30 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LBS/ACRE 10-10-10 FERTILIZER MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, FERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. PERMANENT SEEDING OF SLOPES SEEDING MIXTURE SPECIES TALL FESCUE SERICEA LESPEDEZA KOBE LESPEDEZA RATE (LB/ACRE) 250 20 10 50 SEEDING NOTES 1. AFTER AUGUST 15 USE UNSCARIFIED SERICEA SEED. 2. WHERE PERIODIC MOWING IS PLANNED OR A NEAR APPEARANCE IS DESIRED, OMIT SERICEA AND INCREASE KOBE LESPEZEDA TO 40 LB/ACRE. 3. TO EXTEND SPRING SEEDING DATES INTO JUNE, ADD 15LB/ACRE HULLED BERMUDAGRASS. HOWEVER, AFTER MID-APRIL IT IS PREFERABLE TO SEED TEMPORARY COVER. NURSE PLANTS BETWEEN MAY 1 AND AUGUST 15, ADD 10 LB/ACRE GERMAN MILLET OR 15LB/ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUGUST 15 ADD 40 LB/ACRE RYE (GRAIN). SEEDING DATES FALL: LATE WINTER: BEST POSSIBLE AUGUST 25 - SEPTEMBER 15 AUGUST 20 - OCTOBER 25 FUBRUARY 15 - MARCH 21 FEBRUARY 1 - APRIL 15 FALL IS BEST FOR ALL FESCUE AND LATE WINTER FOR LESPEDEZAS. OVER SEEDING OF KOBE LESPEZEDA OVER FALL -SEEDED TALL FESCUE IS VERY EFFECTIVE. SOIL AMENDMENTS APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 4,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE MULCH. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING OR ROVING OR BY CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MAY BE MOWED ONCE OR TWICE A YEAR, BUT MOWING IS NOT NECESSARY. RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. l GS BY) N N N DATE CITY OF MEBANE COMMENTS REVISIONS I`CDLOd"MNNJ G SERVICES z DRAWING ALTERATION TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER J ISSUE DATE (n u- NOT FOR vo• ON, A �\��. /11111111�� CONSTRUCTION J DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 7- f J 0 0 Z 0 U Z 0 0 W / PROJECT NO. 18-0156 DRAWING NAME: 18-0156_D. dwg SHEET NO. J D-8 GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCGO1 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCGO1 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Stabilize within this Site Area Description many calendar Timeframe variations days after ceasing land disturbance (a) Perimeter dikes, swales, ditches, and perimeter slopes 7 None (b) High Quality Water 7 None (HQW) Zones (c) Slopes steeper than 3:1 7 If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 (d) Slopes 3:1 to 4:1 14 -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed (e) Areas with slopes -7 days for perimeter dikes, swales, ditches, perimeter slopes and HQW Zones flatter than 4:1 14 -10 days for Falls Lake Watershed unless there is zero slope Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. GROUND STABILIZATION SPECIFICATION will not dislodge the soil. Use one of the Stabilize techniques the ground sufficiently so that rain in the table below: Temporary Stabilization Permanent Stabilization • Temporary grass seed covered with straw or other mulches and tackifiers • Hydroseeding • Rolled erosion control products with or without temporary grass seed • Appropriately applied straw or other mulch • Plastic sheeting • Permanent grass seed covered with straw or other mulches and tackifiers • Geotextile fabrics such as permanent soil reinforcement matting • Hydroseeding • Shrubs or other permanent plantings covered with mulch • Uniform and evenly distributed ground cover sufficient to restrain erosion • Structural methods such as concrete, asphalt or retaining walls • Rolled erosion control products with grass seed POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite. 5. Store flocculants in leak -proof containers that are kept under storm -resistant cover or surrounded by secondary containment structures. EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8. Dispose waste off -site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. 11111..A \V d CONCRETE WASHOUT oh -A SANDBAGS (TYP.) OR STAPLES SILT FENCE CLEARLY MARKED SIGNAGE NOTING DEVICE (18"X24" MIN.) PLAN 1:1 SIDE SLOPE (TY P.) ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER 10 MIL PLASTIC SANDBAGS (TYP.) LINING OR STAPLES SECTION A -A NOTES: 1. ACTUAL LOCATION DETERMINED IN FIELD 10' HIGH MIN COHESIVE & LOiB SOIL BIER�TION A A n A / <O O� \VV/> <0> <0> <0 0^0 0 /VVVVI\ _B V 2. THE CONCRETE VVASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY. 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WTH SIGNAGE NOTING DEVICE. BELOW GRADE WASHOUT STRUCTURE NOT TO SCALE CONCRETE VVASHOUT SANDBAGS (TYP.) OR STAPLES CLEARLY MARKED SIGNAGE NOTING DEVICE (18"X24" MIN.) PLAN /9- •*;ww;wk$:. 10 MIL PLASTIC LINING 1:1 SIDE SLOPE (TYP.) SECTION B-B SANDBAGS (TYP.) OR STAPLES HIGH COHESIVE & LOW FILTRATION SOIL BERM NOTES: 1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE VVASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75 % OF THE STRUCTURES CAPACITY TO PROVIDE ADEQUATE HOLDING CAPACITY WTH A MINIMUM 12 INCHES OF FREEBOARD. 3.CONCRETE VVASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WTH SIGNAGE NOTING DEVICE. ABOVE GRADE WASHOUT STRUCTURE NOT TO SCALE CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. NCGO1 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19 r GS BY) N N N DATE CITY OF MEBANE COMMENTS REVISIONS f` Cfl Ln CO CV N- TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER r GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE u- 1 C1 0 X r NOT FOR 4 "llllllll�� CONSTRUCTION J DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 r (PROJECT NO. 18-0156 CV CD CO ti CV U z w z CO w 2 0 J m Cn w 0 i w 0 Z Q z w (7 0 U Z DRAWING NAME: J 1 8-01 56_D.dwg SHEET NO. D-9A SELF -INSPECTION, SECTION A: SELF -INSPECTION PART III RECORDKEEPING AND REPORTING normal business hours in accordance with the table site conditions would cause the safety of the inspection may be delayed until the next business day on In addition, when a storm event of equal to or of normal business hours, the self -inspection shall be of the next business day. Any time when inspections Inspection Record. Self below. personnel which greater performed were -inspections are required during When adverse weather or to be in jeopardy, the inspection it is safe to perform the inspection. than 1.0 inch occurs outside upon the commencement delayed shall be noted in the Inspect Frequency (during normal business hours) Inspection records must include: (1) Rain gauge maintained in good working order Daily Daily rainfall amounts. If no daily rain gauge observations are made during weekend or holiday periods, and no individual -day rainfall information is available, record the cumulative rain measurement for those un- attended days (and this will determine if a site inspection is needed). Days on which no rainfall occurred shall be recorded as "zero." The permittee may use another rain -monitoring device approved by the Division. (2) E&SC Measures At least once per 7 calendar days and within 24 hours of a rain event > 1.0 inch in 24 hours 1. Identification of the measures inspected, 2. Date and time of the inspection, 3. Name of the person performing the inspection, 4. Indication of whether the measures were operating properly, 5. Description of maintenance needs for the measure, 6. Description, evidence, and date of corrective actions taken. (3) Stormwater discharge outfalls (SDOs) At least once per 7 calendar days and within 24 hours of a rain event > 1.0 inch in 24 hours 1. Identification of the discharge outfalls inspected, 2. Date and time of the inspection, 3. Name of the person performing the inspection, 4. Evidence of indicators of stormwater pollution such as oil sheen, floating or suspended solids or discoloration, 5. Indication of visible sediment leaving the site, 6. Description, evidence, and date of corrective actions taken. (4) Perimeter of site At least once per 7 calendar days and within 24 hours of a rain event > 1.0 inch in 24 hours If visible sedimentation is found outside site limits, then a record of the following shall be made: 1. Actions taken to clean up or stabilize the sediment that has left the site limits, 2. Description, evidence, and date of corrective actions taken, and 3. An explanation as to the actions taken to control future releases. (5) Streams or wetlands onsite or offsite (where accessible) At least once per 7 calendar days and within 24 hours of a rain event > 1.0 inch in 24 hours If the stream or wetland has increased visible sedimentation or a stream has visible increased turbidity from the construction activity, then a record of the following shall be made: 1. Description, evidence and date of corrective actions taken, and 2. Records of the required reports to the appropriate Division Regional Office per Part III, Section C, Item (2)(a) of this permit. (6) Ground stabilization measures After each phase of grading 1. The phase of grading (installation of perimeter E&SC measures, clearing and grubbing, installation of storm drainage facilities, completion of all land -disturbing activity, construction or redevelopment, permanent ground cover). 2. Documentation that the required ground stabilization measures have been provided within the required timeframe or an assurance that they will be provided as soon as possible. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. SELF -INSPECTION, RECORDKEEPING SECTION B: RECORDKEEPING PART III AND REPORTING deviation shall be kept on the site. The throughout the coverage under this permit. plan shall be kept on site and available for hours. 1. 2. 3. E&SC Plan Documentation The approved E&SC plan as well as any approved approved E&SC plan must be kept up-to-date The following items pertaining to the E&SC inspection at all times during normal business Item to Document Documentation Requirements (a) Each E&SC measure has been installed and does not significantly deviate from the locations, dimensions and relative elevations shown on the approved E&SC plan. Initial and date each E&SC measure on a copy of the approved E&SC plan or complete, date and sign an inspection report that lists each E&SC measure shown on the approved E&SC plan. This documentation is required upon the initial installation of the E&SC measures or if the E&SC measures are modified after initial installation. (b) A phase of grading has been completed. Initial and date a copy of the approved E&SC plan or complete, date and sign an inspection report to indicate completion of the construction phase. (c) Ground cover is located and installed in accordance with the approved E&SC plan. Initial and date a copy of the approved E&SC plan or complete, date and sign an inspection report to indicate compliance with approved ground cover specifications. (d) The maintenance and repair requirements for all E&SC measures have been performed. Complete, date and sign an inspection report. (e) Corrective actions have been taken to E&SC measures. Initial and date a copy of the approved E&SC plan or complete, date and sign an inspection report to indicate the completion of the corrective action. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above, the following items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides a site specific exemption based on unique site conditions that make this requirement not practical: (a) This General Permit as well as the Certificate of Coverage, after it is received. (b) Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically -available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard -copy records. Documentation to be Retained for Three Years All data used to complete the e-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non -surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a) The E&SC plan authority has been provided with documentation of the non -surface withdrawal and the specific time periods or conditions in which it will occur. The non -surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b) The non -surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c) Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. 2. Occurrences that Must be Reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: • They are 25 gallons or more, • They are less than 25 gallons but cannot be cleaned up within 24 hours, • They cause sheen on surface waters (regardless of volume), or • They are within 100 feet of surface waters (regardless of volume). (c) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (d) Anticipated bypasses and unanticipated bypasses. (e) Noncompliance with the conditions of this permit that may endanger health or the environment. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at (800) 858-0368. Occurrence Reporting Timeframes (After Discovery) and Other Requirements (a) Visible sediment deposition in a stream or wetland • Within 24 hours, an oral or electronic notification. • Within 7 calendar days, a report that contains a description of the sediment and actions taken to address the cause of the deposition. Division staff may waive the requirement for a written report on a case -by -case basis. • If the stream is named on the NC 303(d) list as impaired for sediment - related causes, the permittee may be required to perform additional monitoring, inspections or apply more stringent practices if staff determine that additional requirements are needed to assure compliance with the federal or state impaired -waters conditions. (b) Oil spills and release of hazardous substances per Item 1(b)-(c) above • Within 24 hours, an oral or electronic notification. The notification shall include information about the date, time, nature, volume and location of the spill or release. (c) Anticipated bypasses [40 CFR 122.41(m)(3)] • A report at least ten days before the date of the bypass, if possible. The report shall include an evaluation of the anticipated quality and effect of the bypass. (d) Unanticipated bypasses [40 CFR 122.41(m)(3)] • Within 24 hours, an oral or electronic notification. • Within 7 calendar days, a report that includes an evaluation of the quality and effect of the bypass. (e) Noncompliance with the conditions of this permit that may endanger health or the environment[40 CFR 122.41(1)(7)] • Within 24 hours, an oral or electronic notification. • Within 7 calendar days, a report that contains a description of the noncompliance, and its causes; the period of noncompliance, including exact dates and times, and if the noncompliance has not been corrected, the anticipated time noncompliance is expected to continue; and steps taken or planned to reduce, eliminate, and prevent reoccurrence of the noncompliance. [40 CFR 122.41(1)(6). • Division staff may waive the requirement for a written report on a case -by -case basis. NCGO1 SELF-1NSPECTI0N, REC0RDKEEPING AND REPORTING EFFECTIVE: 04/01/19 r GS BY) N N N DATE CITY OF MEBANE COMMENTS REVISIONS f` Cfl Ln C D N N- r r 1- U w (79 x U w w Z z w 1- U w 3 TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER r GS (GOVINDA.SEDHAY@SUMMITDE.COM) ISSUE DATE u- 1 r NOT FOR r % \ \ ipo,,vim, A 5\\,, CONSTRUCTION} DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court 00 N N U N 0 0 x Fax: (919) 732-6676 r (PROJECT NO. 18-0156 N 0 ti N U z w z CO w 2 d J m w 0 i co 0 z z w (7 0 U z DRAWING NAME: 18-0156_D. dwg SHEET NO. J D-9B vil\Current Drawings \18-0156 D.dwg, D-10 TEMP SEDIMENT BASIN DETAILS, 5/23/2022 4:49:20 PM, govinda.sed N:\2018\18-0156.010 - DRPB Hospitality LLC - Mebane Ho C SILT FENCE DENOTES LIMITS OF DISTURBANCE U7 0 618 u_ cn 0 TOP OF DAM =610.0' 617 616 47 LF 6" PVC INV. DOWN= 605.80' POROUS BAFFLES (TYP) OP-3 2'Lx1.5'Wx12"D CLASS A FINE RIP RAP / TEMPORARY SKIMMER BASIN #1 1"=20' 10.0' CREST OF ha- SPILLWAY=608.0' TOP OF DAM =610.0' \��\/\1 StOpF 2. , GEOTEXTILE LINER/MEMBRANE PER NCDENR REQUIREMENTS SKIMMER BASIN EMERGENCY SPILLWAY NOT TO SCALE 10' WIDE EROSION CONTROL - CLASS B RIP RAP 100 YR. / EMERGENCY SPILLWAY; ELEV.=608.00' SS TEMP. DIVERSION DITCH STRAW WATTLES (TYP.) OP-1 3'Lx2.25'Wx12"D CLASS A FINE RIP RAP 2.5" DIA. SKIMMER W/2.2" DIA. ORIFICE TO REST ON STONE PAD WITH ROPE ATTACHED TO FREE IT SHOULD IT BECOME STUCK DRPBS HOSPITALITY- LOWES BLVD EROSION CONTROL - PHASEI TSB #1 DRAINAGE AREA ac.: 4.58 Q25 cfs (CIA): 12.44 BASIN INFORMATION REQUIRED PROVIDED @ SPILLWAY SURFACE AREA (sf): 5,412 8,926.00 VOLUME (cf): 7,884 14,613.25 DEPTH (ft): 2 2.00 WEIR WIDTH (ft): NA 10 TOP BANK ELEV (ft): NA 610 BOTTOM TRAP ELEV (ft): NA 606 WEIR ELEV (ft): NA 608 DESIGN STORM ELEV (ft): NA 608.37 SKIMMER SIZE (in): 2.5 2.50 ORIFACE SIZE (diameter - in): 2.2 2.2 Basin Dewatering Time, days 3 3 DRPBS HOSPITALITY- LOWES BLVD EROSION CONTROL - PHASE II TSB #1 DRAINAGE AREA ac.: _ 4.06 Q25 cfs (CIA): 26.78 BASIN INFORMATION REQUIRED PROVIDED @ SPILLWAY SURFACE AREA (sf): 11,650 8,926.00 VOLUME (cf): 7,128 14,613.25 DEPTH (ft): 2 2 WEIR WIDTH (ft): NA 10 TOP BANK ELEV (ft): NA 610 BOTTOM TRAP ELEV (ft): NA 606 WEIR ELEV (ft): NA 608 DESIGN STORM ELEV (ft): NA 608.37 SKIMMER SIZE (in): 2.5 2.50 ORIFACE SIZE (diameter - in): 2.2 2.2 Basin Dewatering Time, days 3 3 OP-2 3'Lx2.25'Wx12"D C ASS A FINE RIP RAP (SFO TEMP. DIVERSION DITCH STRAW WATTLES (TYP.) u_ 0 10' WIDE SPILLWAY STABILIZE PER NCDEQ SPECIFICATION USING SOIL STABILIZATION GEOTEXTILE. SEE EC DETAILS. \III/ \III/ \III/ EXISTING POND CONCRETE WASH PIT POROUS BAFFLES (TYP) OP-3 2'Lx1.5'Wx12"D CLASS A FINE RIP RAP DRPBS HOSPITALITY- LOWES BLVD EROSION CONTROL -PHASE I TSB #2 DRAINAGE AREA ac.: 1.17 Q25 cfs (CIA): 3.18 BASIN INFORMATION REQUIRED PROVIDED SPILLWAY' SURFACE AREA (sf): 1,383 7,969.00 VOLUME (cf): 2,106 12,596.75 DEPTH (ft): 2 2 WEIR WIDTH (ft): NA 10 TOP BANK ELEV (ft): NA 621 BOTTOM TRAP ELEV (ft): NA 617 WEIR ELEV (ft): NA 619 DESIGN STORM ELEV (ft): NA 619.37 SKIMMER SIZE (in): 2.5 2.50 ORIFACE SIZE (diameter - in): 2.1 2.1 Basin Dewatering Time, days 3 3 DRPBS HOSPITALITY- LOWES BLVD EROSION CONTROL - PHASE II TSB #2 DRAINAGE AREA ac.: 2.28 Q25 cfs (CIA): 15.04 BASIN INFORMATION REQUIRED PROVIDED SPILLWAY' SURFACE AREA (sf): 6,542 7,969.00 VOLUME (cf): 4,104 12,596.75 DEPTH (ft): 2 2 WEIR WIDTH (ft): NA 10 TOP BANK ELEV (ft): NA 621 BOTTOM TRAP ELEV (ft): NA 617 WEIR ELEV (ft): NA 619 DESIGN STORM ELEV (ft): NA 619.37 SKIMMER SIZE (in): 2.5 2.50 ORIFACE SIZE (diameter - in): 2.1 2.1 Basin Dewatering Time, days 3 3 2.5" DIA. SKIMMER W/2.1" DIA. ORIFICE TO REST ON STONE PAD WITH ROPE ATTACHED TO FREE IT SHOULD IT BECOME STUCK 3:1 SLOPE 621 73 LF 6" PVC INV. DOWN= 617.60' (LD/SF TEMPORARY SKIMMER BASIN #2 1"=20' TOP OF DAM =621' 10.0' CREST OF SPILLWAY=619.0' \ CONSTRUCTION ENTRANCE/EXIT \ 6:1 SLOPE \ \ TOP OF DAM =621.0' \ i\\ \/ 2.0' SLOP \//\ jj\\/ j\ j GEOTEXTILE LINER/MEMBRANE PER NCDENR REQUIREMENTS /\/\\\\\ j\\\\\/\\//� SKIMMER BASIN EMERGENCY SPILLWAY NOT TO SCALE GS m N N N DATE CITY OF MEBANE COMMENTS REVISIONS Nf)C\J J) ENGINEERING SERVICES DRAWING ALTERATION W w Oo�czw=Fx W p pZ O U 0 Z m LL z } U� U :z> ���UW fn}� WQ�w= z� al -lc p a s a, OOU¢QH(n�Nw WWOL: �FaaWa�IWQa w W J w w¢ Q} O m I g009jO°a°pcnoii LL p�=o�z�=�o z c��zQpHxX L. z z Q W Z~ J N p ¢Vo��L=Qa�a 0QUw O0wO6=c[ >LZZ�p W ~O�cn O w _ o ¢ � � w Q L. U U' Z O ¢ 0 0 cn2ZizQCO°Igo Z w ~ i i Z H U w U E2 w w z c� z w H U W O TAS (TIM.SMITH@SUMMITDE.COM) PROJECT MANAGER GS (GOVINDA.SEDHAY@SUMMITDE.COM) FIRST ISSUE DATE NOT 4...c FOR \\\, .. .. . 1 .. .. ////// \�N CAR0// ,,....,., ,.... , : is,... , , ,- .. °HY A •S \\ cA\''S '•///iiiiilii� o CONSTRUCTION.i L IA DESIGN AND ENGINEERING SERVICES State License #: P-0339 320 Executive Court Fax: (919) 732-6676 1 PROJECT NO. 18-0156 DRAWING NAME: 1 8-01 56_D.dwg SHEET NO. D-10 ATTACHMENT 6: DWR PRE -FILING MEETING REQUEST FORM DWR Pre -Filing Meeting Request Form NORTH CAROLINA Environmental Qualify Contact Name* Contact Email Address* Project Owner* Project Name* Project County* Owner Address: * David Cooper dcooper@vhb.com DRPBS Hospitality LLC Lowes Blvd Mebane NC Alamance Street Address 5772 New Castle Lane Address Line 2 City State / Province / Region Bettendorf IA Postal / Zip Code Country 52722 USA Is this a transportation project?* Yes No Type(s) of approval sought from the DWR: 401 Water Quality Certification - 401 Water Quality Certification - Regular Express Individual Permit Modification Shoreline Stabilization Does this project have an existing project ID#?* Yes No Do you know the name of the staff member you would like to request a meeting with? Meeting was declined by Sue Homewood per e-mail on 6/12/2018 Please give a brief project description below and include location information.* The project proposes to construct hotels and office/retail space on a parcel (Alamance Co. Parcel ID 160533, GPIN # 9804937529) at the end of Lowes Blvd in Mebane, NC. The parcel is located adjacent to and south of Hwy. 40/85, between exits 152 and 153. The parcel is currently wooded. Streams and a pond on and adjacent to the site are subject to the Jordan Lake riparian buffer rules. All streams on or adjacent to the site and shown on either the USGS quad or soil survey are considered subject. Riparian buffers will be avoided to the extent practicable. Buffer avoidance has been discussed with Summit Design Engineers (Summit) and the site plan has been modified to move a roadway out of the riparian buffer. At this time, I anticipate only grading and revegetation with grass in Zone 2 to be the only activities within the buffer. We have also discussed diffuse flow, and the site will install riprap dissipator pads at pipes which outlet outside of the buffer, as well as a grassed swale in another area. No stream or pond impacts are proposed. One small jurisdictional wetland will be impacted by the construction. If you have any questions or would like any additional information, please do not hesitate to reach out to me at dcooper@vhb.com. By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: • This form completes the requirement of the Pre -Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. • I understand by signing this form that I cannot submit my application until 30 calendar days after this pre -filing meeting request. • I also understand that DWR is not required to respond or grant the meeting request. Your project's thirty -day clock started upon receipt of this application. You will receive notification regarding meeting location and time if a meeting is necessary. You will receive notification when the thirty -day clock has expired, and you can submit an application. Signature* Submittal Date 9/21/2021