SUBJECT: Compliance Evaluation Inspection
Tyson Hays Hatchery
Other Non -Discharge Wastewater System
Permit No. WQ0020793
Wilkes County
Dear Mr. Parsons:
On June 14, 2022, Division of Water Resources staff Caitlin Caudle completed a
compliance evaluation inspection. James Brown, ORC, Scott Hedrick, and Brianne
Holloway were present during the entire inspection. A review of records, treatment
facilities, and monitoring wells was completed. This review reflected compliance with the
subject permit.
Please refer to the enclosed inspection report for additional comments and observations.
If you have any questions please contact me or Caitlin Caudle at the letterhead address
or phone number, or by email at lon.snider@ncdenr.gov or caitlin.caudle@ncdenr.gov.
Sincerely,
1- DocuSiiggned by:by�
L- l . 5,..aGf
"- 145B49E225C94EA...
Lon T. Snider, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ-WSRO
Enc: Inspection Report
Cc: James Brown, ORC (electronic copy)
Scott Hedrick, Hatchery Supervisor (electronic copy)
Wilkes County Environmental Health (electronic copy)
Laserfiche File WQ0020793
WSRO Electronic Files
GDE
NORTH C
AROLINA '
omm m�� ep..of o�.iXks.
North Carolina Department of Environmental Quality I Division of Water Resources
Winston-Salem Regional Office 1450 W. Hanes Mill Rd, Suite 300 I Winston-Salem, North Carolina 27105
336.776.9800
Compliance Inspection Report
Permit: WQ0020793
SOC:
County: Wilkes
Region: Winston-Salem
Effective: 03/02/20 Expiration: 07/31/26
Effective: Expiration:
Owner : Tyson Farms Inc
Facility: Tyson Farms - Hays Hatchery WWTF
3649 Airport Rd
Hays NC 28635
Contact Person: Kevin Taylor Title: Complex Manager
Directions to Facility:
From Winston Salem, take 421N to Red,white,blue road, to 268 west, then right on airport road.
miles down the road.
System Classifications: WW1,
Primary ORC: Certification:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 06/14/2022
Primary Inspector: Caitlin Caudle
Secondary Inspector(s):
Entry Time 09:58AM Exit Time: 11:30AM
Reason for Inspection: Routine
Permit Inspection Type: Other Non -Discharge Wastewater
Facility Status: Compliant
Question Areas:
❑ Not Compliant
▪ Treatment Flow Measurement -Effluent
▪ Treatment Flow Measurement -Water
Use Records
▪ End Use -Infiltration
▪ Wells
(See attachment summary)
Phone: 336-651-2871
The facility is on the left about 2
Phone:
Phone: 336-776-9699
Inspection Type: Compliance Evaluation
▪ Treatment Flow Measurement -Influent
▪ Treatment
In Treatment Flow Measurement
▪ Miscellaneous Questions
▪ Treatment Barscreen
II Standby Power
Page 1 of 4
Permit: WQ0020793 Owner - Facility:Tyson Farms Inc
Inspection Date: 06/14/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Inspection Summary:
On June 14, 2022, Division of Water Resources staff Caitlin Caudle completed a compliance evaluation inspection. James
Brown, ORC, Scott Hedrick, and Brianne Holloway were present during the entire inspection. A review of records, treatment
facilities, and monitoring wells was completed. This review reflected compliance with the subject permit.
Other observations:
• Three signs are present stating access to the infiltration pond is prohibited. Two signs were repaired from the last
inspection, but one was not. The sign was repaired while Staff was on site.
• The only meter that is part of the treatment train is the flow meter. There is a water meter on site.
• The embankments of the infiltration pond are grassed and mowed. All embankments looked good.
• A sludge survey is completed yearly, and no residuals have been removed from the pond. The screen boxes are cleaned
daily at the end of production.
• Three screen boxes are present at the facility. One is below a load out tank for solid wastes, and the two others are
behind the plant. These two screen boxes collect process water from the plant. See site map for additional information.
• The March 2022 monitoring report was submitted on 4/2/2022 but has not been provided to WSRO. Staff recommended
that Mr. Brown resubmit the report.
• A chart is used to record daily flow and a totalizer is present. The charts are changed daily, and the totalizer recorded
daily. Influent into the infiltration pond is measured.
• All effluent gravity flows to the infiltration pond. Generators are present that can run all electrical components of the
system (aerators, totalizer, and flow meter).
• pH is done in house. Mr. Brown collects effluent samples and well samples. Statesville analytical is used.
• Historic exceedances of NH3 are present in MW2.
• The flowmeter was calibrated on 2/23/2022.
• A defoaming agent has been used in the past but the pump controlling the addition of the agent to the egg was process
is broken. It will be fixed within the next few weeks. Staff have no concerns about this as no foam was present in the
infiltration pond.
• Two aerators are present.
• MW1 had a broken hinge. This was repaired the day of inspection. Phots were provided after the hinge was repaired.
• The well plates of MW1 — MW3 were not appropriately marked by the well installers. Previous DWR staff allowed that
other labels could be applied to the well casings with all necessary information. The current labels had faded, and Staff
recommended that they be replaced within the next few years. Photos were provided of new labels that will be installed on
the well casings.
• MW1 and MW2 are at the review boundary and MW3 and MW4 are at the compliance boundary.
• The current permittee is incorrect. All future correspondence should be directed to Mr. Marty Parsons
(marty.parsons@tyson.com).
Page 2 of 4
Permit: WQ0020793 Owner - Facility:Tyson Farms Inc
Inspection Date: 06/14/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Type
Reuse (Quality)
Lagoon Spray, LR
Single Family Spray, LR
Activated Sludge Spray, LR
Activated Sludge Spray, HR
Activated Sludge Drip, LR
Recycle/Reuse
Single Family Drip
Infiltration System
Treatment
Are Treatment facilities consistent with those outlined in the current permit?
Do all treatment units appear to be operational? (if no, note below.)
Comment: A third bar screen is present.
Treatment Flow Measurement -Influent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment:
Treatment Flow Measurement -Water Use Records
Is water use metered?
Are the daily average values properly calculated?
Comment:
Treatment Flow Measurement -Effluent
Is flowmeter calibrated annually?
Is flowmeter operating properly?
Does flowmeter monitor continuously?
Does flowmeter record flow?
Does flowmeter appear to monitor accurately?
Comment:
Standby Power
Is automatically activated standby power available?
Yes No NA NE
Yes No NA NE
❑ • ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
❑ ❑ • ❑
Yes No NA NE
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
Yes No NA NE
• ❑ ❑ ❑
Page 3 of 4
Permit: WQ0020793 Owner - Facility:Tyson Farms Inc
Inspection Date: 06/14/2022 Inspection Type : Compliance Evaluation
Reason for Visit: Routine
Is generator tested weekly by interrupting primary power source?
Is generator operable?
Does generator have adequate fuel?
Comment:
Treatment Barscreen
Is it free of excessive debris?
Is disposal of screenings in compliance?
Are the bars spaced properly?
Is the unit in good condition?
Comment:
End Use -Infiltration
# Is the application High Rate or Low Rate?
Are buffers maintained?
Are any supply wells within the CB?
Are any supply wells within 250' of the CB?
Is municipal water available in the area?
Are GW monitoring wells required?
Are GW monitoring wells located properly w/ respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
Is a usable green area maintained?
Is the disposal site acceptable?
Is the distribution equipment acceptable?
Is the disposal site free of ponding?
Is the disposal site free of breakout?
Are the disposal sites free of solids, algae, etc.?
Do the records show that the fields are properly maintained?
Are the disposal sites free of vegetation?
Do any surface water features appear to be adversely impacted by GW discharge?
No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.?
Comment: No evidence of groundwater impacts.
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑