HomeMy WebLinkAboutWQ0015487_Permit Application Review Comments_19980730DIVISION OF WATER QUALITY GROUNDWATER SECTION July 30, 1998 MOOR C�Jt7s�i11I �1 To: Kim Colson Through: Bob Cheek pb L From: David Goodrich Subject: Powell Industries 336,000 GPD Washwater Recycle System Haywood County W00015487/GW98092 (Randy Kepler: DEM SERG Review Engineer) IN MUG - 41998 GROUNDWATER S--ION ,'ILLE RhG10NAt OFFICE The Groundwater Section is in receipt of the subject application to permit a 336,000 GPD washwater recycle system at the Powell Industries log yard in Haywood County (see Figures 1 and 2). The system will include a 360,000 gallon capacity recirculation pond which will be used to store and recirculate used washwater. Thepurpose of this system is to use conventional, pressure -animated sprinklers to wash logs which will.. be used ina wood chipping operation. It is the understanding of the Groundwater Section that the material being removed from the logs by the washwater will consist of soil particles with a typical size of 0.05 to 0.06 millimeters. These soil particles will be suspended in the water which will be directed back to the recirculation pond. It is also the understanding of the Groundwater Section that no chemicals or other foreign substances will be added to the wash water, that no chemical substances will be applied to the logs prior to the washing process, nor will the logs be otherwise exposed to environments which could chemically compromise the nature of the tree bark, or the soil which is to be washed off. The permit application materials in the submittal package did not indicate the installation of a liner around the inside of the 360,000 gallon recirculation pond. It is therefore possible that this pond may have hydraulic contact with the shallow ground water environment. Based on these understandings, the Groundwater Section recommends issuance of the permit with the following conditions: 1. Any groundwater quality monitoring, as deemed necessary by the Division, shall be provided. r r 2. The COMPLIANCE BOUNDARY for the disposal system is specified by regulations in 15A NCAC 2L, Groundwater Classifications and Standards. The Compliance Boundary is for the disposal system individually permitted after December 31, 1983 is established at either (1) 250 feet from the waste disposal area, or (2) 50 feet within the property boundary, whichever is closest to the waste disposal area. An exceedance of Groundwater Quality Standards at or beyond the Compliance Boundary is subject to immediate remediation action in addition to the penalty provisions applicable under General Statute 143-215.6A(a)(1). In accordance with 15A NCAC 2L, a REVIEW BOUNDARY is established around the disposal systems midway between the Compliance Boundary and the perimeter of the waste disposal area. Any exceedance of standards at the Review Boundary shall require remediation action on the part of the pemuttee. If there are any questions please let me know. cc: Don Link Permit Files --POWELLIN-- ' j f N SCALE IN FEET 0 2,000 4,000 r J 0 35' 5/T€ ,cep 1 T 4 1. FIGURE 1 POWELL INDUSTRIES cra 336,000 GPD RECYCLE SYSTEM ' ao ��. HAYWOOD COUNTY WQ0015487/GW98092 :� /:. SITE LOCATION MAP C II_� - � --i'l1!�l�-�V" • �A`�1�1i I7A ' 6za 3A ,23A 7 411 / f Wong / Fora �AIJZ) , o 35.2A- / 1 2A Tc 4649`�✓ J �` J�V / 62 LOA 4133 9', 9- i 31 HAYWOOD COUNTY 1 in = 316.60 feet Farce!: 8609-72-6324 4 b Date: 06J05J98 pFIGURE 2 POWELL INDUSTRIES 336,000 GPD RECYCLE SYSTEM HAYWOOD COUNTY LAND RECORDS WQ0015487/GW98092 GEOGRAPHIC INFORMATION SITE DETAIL MAP