HomeMy WebLinkAboutNCG551164_Inspection_20220527DocuSign Envelope ID: ODEFC72B-A825-4D57-BC5E-1DC8ADB894CA
ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RICHARD E. ROGERS, JR.
Director
NORTH CAROLINA
Environmental Quality
May 27, 2022
Charles Michael Poole
226 Hocutt Road
Durham, NC 27703
Certified Mail # 7020 3160 0000 4115 3586 Return Receipt Requested
Subject: NOTICE OF VIOLATION & INTENT TO ASSESS
CIVIL PENALTY
Tracking Number: NOV-2022-PC-0281
Compliance Evaluation Inspection
General NPDES Permit NCG550000
Certificate of Coverage NCG551164
Facility: 226 Hocutt Road // Durham County
Dear Mr. Poole:
This letter serves as a Notice of Violation (NOV) of General NPDES Permit No. NCG550000,
Certificate of Coverage No. NCG551305, and North Carolina GS § 143-215.1(a). The following
deficiencies have been previously noted in prior inspection reports and were again noted during
this inspection: Failure to provide proof of septic pumping records (noted in 2017); failure to
provide effluent sampling results (noted in 2008, 2014, and 2017); no chlorine tablets were
observed in the chlorinator and/or the permittee did not have the proper chlorine tablets (noted in
2008, 2014, and 2017). Within 30-days receipt of this letter, please submit a written response to
this office indicating the actions you will take or have taken to comply with or resolve these
issues and the issues noted on the following pages.
On April 28, 2022, Alys Hannum from the Raleigh Regional Office visited your single-family
residence wastewater treatment system to evaluate compliance with the subject General National
Pollution Discharge Elimination System (NPDES) Permit. Your assistance during the inspection
was greatly appreciated.
Our records indicate the treatment system consists of a septic tank, sub -surface sand filter, tablet
chlorinator with chlorine contact chamber, discharge pipe and a rip -rap apron for post aeration.
General NPDES Permit NCG550000 and Certificate of Coverage (COC) NCG551164 authorize
the discharge of domestic wastewater from your treatment system to receiving waters designated
as an unnamed tributary to Little Lick Creek in the Neuse River Basin, in accordance with the
effluent limits and monitoring requirements established within the General Permit. The following
conditions were noted at your facility:
NORTH CAROLINA
Department of Environmental Quality
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: ODEFC72B-A825-4D57-BC5E-1DC8ADB894CA
Charles M. Poole, NCG551164
May 23, 2022
Page 2 of 3
• Pumping the septic tank: You are required to inspect the septic tank at least yearly to
determine if solids must be removed or if other maintenance is necessary. Septic tanks
should be pumped out every five years or when the solids level is found to be more than
1/3 of the liquid depth in the septic tank compartment, whichever is greater. A pumping
company can check the status periodically and determine when pumping is required. The
General NPDES Permit requires the permittee to retain records associated with sewage
disposal activities for a period of at least 5 years.
Within 30-days of receiving this letter, please send a copy of the most recent
receipt/invoice to this office showing the date the septic tank was last checked and/or
pumped out.
• Chlorine tablets in the chlorinator: You are reminded that it is required that chlorine
tablets be maintained in the chlorinator to ensure proper disinfection of the discharged
wastewater. Chlorine tablets provide effective disinfection and prevent/limit harmful
bacteria from discharging to the environment. The product label for these tablets must
indicate the tablets are approved for wastewater use and not for swimming pools. Part 1,
Section D (1) of General NPDES Permit NCG550000 requires the permittee to inspect
the tablet chlorinator weekly to ensure there is an adequate supply of tablets for
continuous and proper operation. Section D (4) requires the permittee to maintain all
system components in good operating order.
The inspector did not observe any chlorine tablets in the chlorinator, and your bucket of
chlorine tablets was expired. Please ensure the correct type of tablets are used and
maintained in the chlorinator as required by the General NPDES Permit.
• Analyzing the effluent: Part 1. C., Effluent Limitations and Monitoring Requirements,
within General Permit NCG550000 requires a permittee to sample and analyze the
effluent leaving his/her treatment system prior to discharge annually. Parameters to be
sampled and analyzed include Flow, BOD (Biochemical Oxygen Demand), Total
Suspended Solids, Fecal Coliform and Total Residual Chlorine.
Within 30-days of receiving this letter, please inform this office if you have monitored
your effluent discharge within the last 12 months and provide a copy of the lab results if
you have. If you have not monitored your effluent, then please collect a representative
sample of the effluent, have it analyzed by a certified commercial laboratory and submit
the results to this office within 90 days. If, during this time, you are unable to collect a
representative sample of the effluent discharge due to insufficient flow from the
discharge pipe, then update this office with that information and continue to monitor the
discharge and if conditions for sampling become favorable, then arrange to collect a
sample. Failure to monitor the effluent discharge as required is a violation of NPDES
General Permit NCG550000.
GD_E
NORTH CAROLINA
Department of Environmental Quality
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: ODEFC72B-A825-4D57-BC5E-1DC8ADB894CA
Charles M. Poole, NCG551164
May 23, 2022
Page 3 of 3
• Discharge outlet location. The permittee is required to conduct a visual review of the
outfall location at least twice each year (one at the time of sampling) to ensure that no
visible solids or other obvious evidence of system malfunctioning is observed. Any
visible signs of a malfunctioning system shall be documented and steps taken to correct
the problem.
The end of discharge pipe was not visible nor accessible the day of the inspection. To
comply with the general permit monitoring requirements, you need to be able to sample
and analyze the effluent from your SFR system through the discharge pipe. Please take
the necessary steps to ensure the discharge outlet is visible and accessible. Maintaining
the area will allow you to monitor the discharge and to collect effluent samples as
required by the subject permit.
Division records indicate the required annual fee ($60 per year) due December 2, 2021, for the
period ending November 30, 2022, has been paid. There are no overdue fees for the subject
COC.
Within 30-days receipt of this letter, please submit a written response to this office indicating
the actions you will take or have taken to comply with or resolve the issues noted above.
If you have questions or comments about this inspection or the requirements to take corrective
action, please contact Alys Hannum at alys.hannum@ncdenr.gov, or by phone at 919-791-4255.
Sincerely,
Docu Signed by:
[yatiu-ssa, f. 41444A,uc,(,
B2916E6AB32144F...
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s): EPA Water Compliance Inspection Report
cc: RRO/SWP Files
Laserfiche
dD_E
NORTH CAROLINA
Department of Environmental Quality
North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 13800 Barrett Drive I Raleigh, North Carolina 27609
919.791.4200
DocuSign Envelope ID: ODEFC72B-A825-4D57-BC5E-1DC8ADB894CA
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction
1 IN
21IIIIII
Code
I 2 IL
NPDES yr/mo/day Inspection
I 3 I NCG551164 111 121 22/04/28 117
Type
1810I
IIIIIIIIIII
Inspector Fac Type
19I S I 2011
IIIIIIIIIII IIIIIII I IIIIII
P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
671 I 70I2 I 711 1 72 I N I 73I 1 74 71
I I
I I I I I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES oermit Number)
226 Hocutt Road
226 Hocutt Rd
Durham NC 27703
Entry Time/Date
02:OOPM 22/04/28
Permit Effective Date
21/12/28
Exit Time/Date
02:30PM 22/04/28
Permit Expiration Date
25/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Charles Michael Poole,226 Hocutt Rd Durham NC 27703//919-598-0234/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Operations & Maintenar Self -Monitoring Progran
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Alys K Hannum
of Inspector(s) Agency/Office/Phone and Fax Numbers Date
c- DocuSigned by:
DWR/RRO WQ/919-791-4255/ 5/23/2022
"-4C22170C5AA04F3...
Signature
of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
IDocuSigned by:
ou,SSa f. hautd,l, 5/24/2022
m35vEPA Form t e9-94) Previous editions are obsolete.
Page# 1
DocuSign Envelope ID: ODEFC72B-A825-4D57-BC5E-1DC8ADB894CA
NPDES yr/mo/day
31 NCG551164 111 121 22/04/28
I17
Inspection Type
18LI
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
DocuSign Envelope ID: ODEFC72B-A825-4D57-BC5E-1DC8ADB894CA
Permit: NCG551164
Inspection Date: 04/28/2022
Owner -Facility: 226 Hocutt Road
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ � ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Septic Tank
(If pumps are used) Is an audible and visual alarm operational?
Is septic tank pumped on a schedule?
Are pumps or syphons operating properly?
Are high and low water alarms operating properly?
Yes No NA NE
❑ ❑ • ❑
• ❑ ❑ ❑
❑ ❑ • ❑
Comment: Resident has not provided proof of recent pumping. This issue was also noted on the
inspection report in 2017.
Sand Filters (Low rate)
(If pumps are used) Is an audible and visible alarm Present and operational?
Is the distribution box level and watertight?
Is sand filter free of ponding?
Is the sand filter effluent re -circulated at a valid ratio?
# Is the sand filter surface free of algae or excessive vegetation?
# Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1)
Comment:
Yes No NA NE
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
• ❑ ❑ ❑
Disinfection -Tablet Yes No NA NE
Are tablet chlorinators operational? • ❑ ❑ ❑
Are the tablets the proper size and type? ❑ • ❑ ❑
Number of tubes in use? 2
Is the level of chlorine residual acceptable? ❑ ❑ ❑ •
Is the contact chamber free of growth, or sludge buildup? • ❑ ❑ ❑
Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ •
Comment: Chlorine tablets were expired. The resident did not have chlorine tablets in the
chlorinator during the inspections in 2008, 2014, and 2017.
Effluent Sampling
Is composite sampling flow proportional?
•
Yes No NA NE
❑ ❑ ❑
Page# 3
DocuSign Envelope ID: ODEFC72B-A825-4D57-BC5E-1DC8ADB894CA
Permit: NCG551164
Inspection Date: 04/28/2022
Owner -Facility: 226 Hocutt Road
Inspection Type: Compliance Evaluation
Effluent Sampling Yes No NA NE
Is sample collected below all treatment units? • ❑ ❑ ❑
Is proper volume collected? El • El El
Is the tubing clean? ❑ El • El
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ • ❑
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type ❑ • ❑ ❑
representative)?
Comment: Resident has not provided lab results. This issue was also noted on the inspection
reports in 2008, 2014, and 2017. No sampling results exist in our file.
Page# 4