Loading...
HomeMy WebLinkAboutNCC222157_Site Plan or Location Map_20220616I- � I I �-BAYtDSON HOUSING COAL PROPOSED PEDESTRIAN SCALE LIGHTING SEE DETAIL 8/C-805, INSTALLATION IN003-231-23 PER DUKE ENERGY AND TOWN OF DAVIDSON STANDARDS. DB.20779, PG.18: SEE C-700` FOR STREET LIGHT REQUIREMENTS. \ 1 PROPOSED PAVEMENT MARKING DENOTING THE START OF ON -STREET PARKING. PROPOSED PARKING SIGN, SEE DETAIL 11 /C-805. 0 8+15.73 8+00 7+00 6+00 �• +- S+nn A 1 1 / 1 1 1\m 1\M 1 PROPOSED FUTURE STREET CONNECTION SIGNAGE, SEE DETAIL 9/C-805. r PROPOSED FUTURE STREET \ CONNECTION SIGNAGE, \ SEE DETAIL 9/C-805. 1 1 \ 1 \ 1 PROPOSED PROPERTY BOUNDARY $k101 _ _ 003-205-27 003-205-26 86,34226_ PG.637 DB.NA 1 STAKING AND MATERIALS NOTES 1. ALL DIMENSIONS ARE TO BACK OF CURB, FACE OF BUILDING, OR CENTERLINE UNLESS OTHERWISE NOTED. 2. RADIUS DIMENSIONS ARE TAKEN TO THE BACK OF CURB. 3. ALL DIMENSIONS ARE AT 90 DEGREES UNLESS OTHERWISE NOTED. 4. PARKING STALL DIMENSIONS ARE 18.0' (TO FACE OF CURB) X 9.0' WIDE UNLESS OTHERWISE NOTED. PARALLEL PARKING SPACES ARE 22' X 7.5' (TO FACE OF CURB) UNLESS OTHERWISE NOTED. 5. ALL BACK OF CURB RADII AT ROADWAY INTERSECTIONS SHALL BE 20-FEET UNLESS OTHERWISE NOTED. 6. REFER TO ARCHITECTURAL PLANS FOR ACTUAL BUILDING DIMENSIONS. 7. ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS SHALL BE CALLED TO THE ATTENTION OF THE OWNER AND ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 8. THE CONTRACTOR SHALL CONTACT ALL OWNERS OF UTILITIES, EASEMENTS, AND RIGHTS -OF -WAY, PUBLIC AND PRIVATE, PRIOR TO WORKING IN THESE AREAS. 9. ALL ASPHALT PAVING SHALL CONFORM TO THE APPLICABLE PROVISIONS OF THE NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES, LATEST EDITION. 10. CONTRACTOR SHALL FURNISH AND INSTALL ALL PAVEMENT MARKINGS AS SHOWN ON THE PLANS. 11. ALL SIGNS, PAVEMENT MARKINGS, AND OTHER TRAFFIC CONTROL DEVICES SHALL CONFORM TO THE LATEST EDITION OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). 12. ALL PARKING STALL STRIPING SHALL BE 4-INCH WHITE LINES, UNLESS OTHERWISE NOTED. 13. STOP SIGNS SHALL BE R1-1, 30%30". 14. SIGHT TRIANGLES SHOWN ARE THE MINIMUM REQUIRED. 15. NO DEMOLITION LANDFILLS ALLOWED ON SITE. 16. CURB AND GUTTER VARIES AT CATCH BASIN LOCATION. SEE DETAIL 4/C-801 FOR CATCH BASIN PLACEMENT AND CURB TRANSITIONS. 17. ALL SIDEWALKS LOCATED IN THE RIGHT-OF-WAY TO BE 5' WIDE WITH THE EXCEPTION OF JETTON STREET AND CATAWBA AVENUE IN WHICH THE PROPOSED SIDEWALKS ARE 6' WIDE. HOWEVER, THE PROPOSED SIDEWALK EXTENSION ON THE SOUTH SIDE OF CATAWBA AVENUE IS 5' WIDE TO MATCH THE EXISTING SIDEWALK. 18. ALL OPEN SPACES, PATHS, AND PARK SPACES (INCLUDING PARK FEATURES) SHALL BE PUBLICLY -ACCESSIBLE AND PRIVATELY MAINTAINED. PAVEMENT REPAIR NOTES 1. CONTRACTOR SHALL PERFORM THE FOLLOWING REPAIR WORK AT THE EXISTING ASPHALT SURFACES: 1.a. SAW -CUT AND REMOVE AREAS OF STRUCTURALLY -DEFICIENT PAVEMENT. RE -COMPACT SUB -GRADE AND INSTALL FULL DEPTH ASPHALT PATCH (MIN. 2" S9.56) 1.b. CLEAN ALL LONGITUDINAL AND TRANSVERSE CRACKS GREATER THAN )'" WIDE AND LESS THAN 1" WIDE AND FILL WITH A HOT POUR RUBBER ASPHALT JOINT SEALER MEETING NCDOT SPECIFICATIONS. 1.c. CLEAN AND FILL ALL CRACKS GREATER THAN 1" WIDE WITH A HOT, DENSE -GRADED, ASPHALT PATCH. 1.d. CLEAN ALL SURFACES AND APPLY TWO COATS OF A COAL -TAR EMULSION SEAL COAT AT A MINIMUM RATE OF 0.2 GALLONS/S.Y. I PROPOSED RIGHT-OF-WAY LINE ,� VJ I CHURCHIVIDSON PRES LEIGH IHUTHER TYLER M HELFRICH DANIEL C BARR I Q3-205-24 l 003-205-42 003-205-41 I KATHRYN L C BARR 'D�. NA I i DB.32263, PG.301 DB.32210, PG.223 I D6.33317, PG.7n - \ � it DEVELOPMENT SUMMARY PROJECT NAME: HOKE TOWNHOMES OWNER/APPLICANT: TAYLOR MORRISON HOMES 11405 N COMMUNITY HOUSE RD SUITE 150, CHARLOTTE, NC 28277 JURISDICTION: TOWN OF DAVIDSON MECKLENBURG COUNTY, NC PLANNING AREAS + PARCEL IDs: LAKESHORE (LK): 00321103, 00321112, 00324301, 00324306 VILLAGE INFILL (V): 00324303, 00324304, 00324305 EXISTING USE: LUMBER YARD/SINGLE FAMILY RESIDENTIAL PROPOSED USE: RESIDENTIAL TOWNHOME BUILDING TYPE SITE ACREAGE: 5.546 ACt 4.878 AC f (LK) 0.668 ACt (VI) TYPICAL LOT SIZE: 21'x52.25' TOTAL UNITS: 81 AFFORDABLE HOUSING UNITSt 8 BUILDING SETBACKS: LAKESHORE (LK) FRONT: 5' MIN, 10' MAX SIDE: 5' MIN, 10' MAX REAR: 5' MIN, NA MAX VILLAGE INFILL (VI) 5' MIN, 10' MAX FRONT: SIDE: 10' MIN, NA MAX REAR: 5' MIN, NA MAX BUILDING SEPARATION: 10' MIN. BASED ON 5' SIDE YARD PARKING: FORMAL ON-STREET- JETTON STREET: 14 SPACES CATAWBA AVENUE: 14 SPACES 28 SPACES INFORMAL ON -STREET*: PARK DRIVE: 11 SPACES HAMILTON STREET, 3 SPACES 14 SPACES *THE NUMBER OF INFORMAL ON -STREET PARKING SPACES IS APPROXIMATED. OPEN SPACE: - LAKESHORE REQUIRED: t0.24 AC (5%) - LAKESHORE PROVIDED: f1.24 AC (25%) - VILLAGE INFILL REQUIRED: t0.07 AC (107.) - VILLAGE INFILL PROVIDED: t0.67 AC (100%) TOTAL OVERALL: f1.91 AC (34%) PARK SPACE: - LAKESHORE REQUIRED: t0.05 AC (5% OF OPEN SPACE) - LAKESHORE PROVIDED: f1.24 AC (257.) - VILLAGE INFILL REQUIRED: t0.03 AC (5% OF OPEN SPACE) - VILLAGE INFILL PROVIDED: f0.67 AC (1007.) TOTAL OVERALL: t1.91 (34%) WATERSHED: LAKE NORMAN CRITICAL AREA: MAXIMUM 50% BUILT -UPON AREA. 51.7% (MINOR VARIANCE GRANTED BY BOARD OF ADJUSTMENT- RULING FILED WITH THE TOWN OF DAVIDSON PLANNING DIRECTOR 3/19/2021) CATAWBA NEIGHBORHOOD GENERAL ROW: 31.5' FROM CENTERLINE JETTON NEIGHBORHOOD GENERAL ROW: 31.5' FROM CENTERLINE PARK DRIVE NEIGHBORHOOD YIELD ROW: 52' HAMILTON STREET NEIGHBORHOOD YIELD ROW: 35' ALLEY ROW: 20' ESTIMATED CONSTRUCTION START DATE: NOV 2021 ESTIMATED CONSTRUCTION COMPLETION: NOV 2024 NOTES: 1. AFFORDABLE HOUSING: 8 AFFORDABLE HOUSING UNITS TO BE DISPERSED THROUGHOUT THE SITE. FOR MORE INFORMATION REFERENCE THE AFFORDABLE HOUSING PLAN APPROVED BY THE DAVIDSON BOARD OF COMMISSIONERS APRIL 27, 2021. DEED RESTRICTIONS: 1. PARKING IN THE ALLEYS IS PROHIBITED. 2. ALLOWANCE OF ANY ADDITIONAL IMPERVIOUS AREA WITHIN THE LOTS BEYOND WHAT IS APPROVED IN THE PERMITTED PLAT PLANS IS PROHIBITED. PROPOSED CATS/CMS BUS SHELTER. IMPROVEMENTS TO JETTON STREET -ONLY APPLY TO SITE'S FRONTAGE. - -PROPOSED PARK SIGN, TYP. FINAL LOCATION AND DESIGN TO BE COORDINATED WITH THE TOWN OF DAVIDSON PLANNING DEPARTMENT. 0+00 I i _U C) / KARA L SUTER W / 003-243-02 C) Z / )B.33157, PG.299 x (n I / I I �X I I i m �\ M I I ' I � I I I 1 •� Y RELOCATED POWER POLE LOCATIONS ARE APPROXIMATE. :,. CONTRACTOR TO ;:• COORDINATE WITH DUKE ENERGY FOR FINAL LOCATIONS. IMPROVEMENTS TO CATAWBA AVENUE ONLY APPLY TO SITE'S FRONTAGE. I JAM GLE DR, RELOCATED STOP SIGN/ ySTREET SIGN. I LT 0+00 KEVIN P C-09ME R 1- ROSS F ATHE TON ' \ - MARY C CONNERY MELISSA ATHER�ON \ TIMOTHY S PRATT \ ERIKA A PRATT CLA�(M HOOP - 003-205-22 DB.31356, PG.443 - ' \ 003 205-21 \ 'IDB.31673, PG.94 \ \ 003-205-20 �9 SHANN N L HOOPER 003 05-19 D6\32-424, PG.815 DB.3321 , PG.195 IMPERVIOUS CALCULATIONS TOTAL PROJECT BOUNDARY AREA: t5.35 AC (t232,930 SF) EXISTING IMPERVIOUS: 80.7% (f185,959 SF, f4.27 AC) ALLOWABLE BUA1: 51.7% PROPOSED ONSITE IMPERVIOUS PER PLAN 2: (51.2% ±119,410 SF, t2.74 AC) BUILDING 68,344 SF (29.3%) STREET 24,485 SF (10.5%) DRIVEWAY 13,759 SF (5.9%) SIDEWALK 12,484 SF (5.4%) FUTURE ALLEY4 338 SF (0.1%) PROPOSED OFFSITE IMPERVIOUS5: ±26,583 SF (f0.61 AC) 1 PROJECT PROPOSES 51.2% (MINOR VARIANCE GRANTED BY BOARD OF ADJUSTMENT- RULING FILED WITH THE TOWN OF DAVIDSON PLANNING DIRECTOR 3/19/2021). REMAINING ALLOWABLE BUILT -UPON AREA TO BE UTILIZED IN PARK/OPEN SPACE DESIGN. LANDSCAPE RTAP TO BE SUBMITTED PRIOR TO FINAL PLAT APPROVAL. 2 PER CHAPTER 17.7.1.2.0 OF THE TOWN OF DAVIDSON PLANNING ORDINANCE WATERSHED PROTECTION OVERLAY DISTRICT, ATTACHED HOME DEVELOPMENTS ARE REQUIRED TO RESERVE 150 SQ. FT OF IMPERVIOUS AREA PER LOT TO ALLOW FOR FUTURE IMPERVIOUS INSTALLED BY THE HOMEOWNER/OCCUPANT. BASED ON THE LOT SIZE PROPOSED WITHIN THIS DEVELOPMENT, THE ATTACHED TOWNHOME LOTS DO NOT SUPPORT ADDITIONAL BUILT -UPON AREA BEYOND WHAT IS CURRENTLY SHOWN ON THE PLANS IN A WAY THAT WOULD BE IN KEEPING WITH THIS RULE. IN ORDER TO MEET THIS FUTURE RESERVED BUA (BUILT -UPON AREA) REQUIREMENT THE DEVELOPER PROPOSES TO RECORD A DEED RESTRICTION AND HOA COVENANT ON THE PROPERTY THAT ELIMINATES THE ALLOWANCE OF ANY ADDITIONAL IMPERVIOUS AREA WITHIN THE LOTS BEYOND WHAT IS APPROVED IN THE PERMITTED PLAT PLANS. 3 STREET BUA INCLUDES ALLEY BUA. 4 FUTURE ALLEY ACCOUNTS FOR THE ADDITIONAL BUA ASSOCIATED WITH THE EXTENSION OF THE WESTERN ALLEYS SHOULD THE ADJACENT PROPERTY DEVELOP. 5 OFFSITE IMPERVIOUS INCLUDES PROPOSED IMPROVEMENTS ALONG JETTON STREET, CATAWBA STREET, AND HAMILTON STREET. r� Sire �2 O �CqTA� C1 VICINITY MAP 1T = 500, SURVEY ISSUE DATE AUGUST 27, 2018. PROVIDED BY R.B. PHARR & ASSOCIATES, P.A. 420 HAWTHORNE LANE, CHARLOTTE, NC 28204 (704) 376-2186 LEGEND SYMBOL DETAIL PROPOSED SIDEWALK 9/C-802 PROPOSED BOARDWALK -/- PROPOSED MULCH PATHWAYS -/- PEDESTRIAN ACCESS EASEMENT -/- `'' PROPOSED ACCESSIBLE RAMP 3/C-803 :;.':.. •..�::::':;.• PROPOSED DIRECTIONAL 2/C-803 " ACCESSIBLE RAMP S_ PROPOSED STOP SIGN -/- PROPOSED PARKING SIGN 11,12/C-805 9/C-806 PROPOSED STREET SIGN 8,12/C-800 ® PROPOSED PARK SIGN 10/C-804 ............... LIGHT DUTY CONCRETE -/- PROPOSED 2'-0" CURB & GUTTER 6/C-802 NATIONAL REGISTER HISTORIC DISTRICT -/- PEDESTRIAN STREET LIGHTING 8/C-805 ;;5 � G7 1. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND ENSURING THAT ALL EXISTING UTILITIES ARE LOCATED PRIOR TO CONSTRUCTION. 2. CONTRACTOR IS RESPONSIBLE FOR PLACING BARRICADES, USING FLAG MEN, ETC., AS NECESSARY TO ENSURE THE SAFETY OF THE PUBLIC. 3. ALL PAVEMENT CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED ACCORDING TO THE STANDARDS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION, OR LOCAL JURISDICTION, WHICHEVER IS MORE STRINGENT. 4. SHORING SHALL BE IN ACCORDANCE WITH OSHA TRENCHING STANDARDS, 29 CFR, PART 1926, SUBPART P, OR AS AMENDED. ColeJenest & Stone Shaping the Environment Realizing the Possibilities Land Planning Landscape Architecture Civil Engineering Urban Design 200 South Tryon Street, Suite 1400 Charlotte, North Carolina 28202 p+ 704 376 1555 f+ 704 376 7851 url+ www.colejeneststone.com TAYLOR MORRISON HOMES 11405 N COMMUNITY HOUSE ROAD SUITE 150, CHARLOTTE, NC 28277 HOKE TOWNHOMES 351 JETTON STREET DAVIDSON, NC 28036 OVERALL DIMENSION CONTROL PLAN Project No. 4654 Issued 05/10/2021 Revised ,%1��pN & MFiL.� u ..•Rp OR.q SEAL m F-1409 C-596 TyCAR��� •CA ti E L �• 038668 n►��`�05/10/21 N SCALE: 1 "=30' 0 15' 30' 60' Cm200 The drawings, the project manual and the design shown theron are instruments of ColeJenest & Stone, P.A.. The reproduction or unauthorized use of the documents without consent of ColeJenest & Stone, P.A. is prohibited. ColeJenest & Stone, P.A. 2020