Loading...
HomeMy WebLinkAboutWI0501094_Notification of Intent (NOI) – GW Remediation_20220614NC Department of Environmental Quality — Division of Water Resources (DWR) NOTIFICATION OF INTENT (NOI) TO CONSTRUCT OR OPERATE INJECTION WELLS The following are `permitted by rule" and do not require an individual permit when constructed in accordance with the rules of15A NCAC 02C.0200 (NOTE: This form must be received at least 14 DAYS prior to infection) AQUIFER TEST WELLS (15A NCAC 02C .0220) These wells are used to inject uncontaminated fluid into an aquifer to determine aquifer hydraulic characteristics. IN SITU REMEDIATION (15A NCAC 02C .0225) or TRACER WELLS (15A NCAC 02C .0229): 1) Passive Injection Systems - In -well delivery systems to diffuse injectants into the subsurface. Examples include ORC socks, iSOC systems, and other gas infusion methods (Note: Injection Event Records (IER) do not need to be submitted for replacement of each sock used in ORC systems). 2) Small -Scale Injection Operations — Injection wells located within a land surface area not to exceed 10,000 square feet for the purpose of soil or groundwater remediation or tracer tests. An individual permit shall be required for test or treatment areas exceeding 10,000 square feet. 3) Pilot Tests - Preliminary studies conducted for the purpose of evaluating the technical feasibility of a remediation strategy in order to develop a full scale remediation plan for future implementation, and where the surface area of the injection zone wells is located within an area that does not exceed five percent of the land surface above the known extent of groundwater contamination. An individual permit shall be required to conduct more than one pilot test on any separate groundwater contaminant plume. 4) Air Injection Wells - Used to inject ambient air to enhance in -situ treatment of soil or groundwater. 5) In -Situ Thermal Wells (IST) — Used to `heat' contaminated groundwater to enhance remediation. Print Clearly or Type Information. Illegible Submittals Will Be Returned as Incomplete. DATE: May 20 , 2022 PERMIT NO. (to be filled in by DWR) NOTE- If this NOI is being submitted as notification of a modification of a previously issued NOI for this site (e.g., different injection wells, plume, additives, etc.) and still meets the deemed permitted by rule criteria, provide the previously assigned permit tracking number and any needed relevant information to assess and approve injection: A. B. Permit No. WI0501070 Issued Date: March 9, 2021 WELL TYPE TO BE CONSTRUCTED OR OPERATED (1) Air Injection Well Complete sections B through F, J, M (2) Aquifer Test Well Complete sections B through F, J, M (3) Passive Injection System Complete sections B through F, H-M (4) Small -Scale Injection Operation Complete sections B through M (5) X Pilot Test Complete sections B through M (6) Tracer Injection Well Complete sections B through M (7) In -Situ Thermal (IST) Well Complete sections B through M STATUS OF WELL OWNER: Business/Organization Deemed Permitted GW Remediation NOI Rev. 2-17-2020 Page 1 C. WELL OWNER(S) — State name of Business/Agency, and Name and Title of person delegated authority to sign on behalf of the business or agency: Name(s): Eaton Corporation: Jeffrey P. Allen Mailing Address: Mail Code 4S, 1000 Eaton Blvd City: Cleveland State: OH Zip Code: 44122 County: Cuyahoga Day Tele No.: 440-523-4777 Cell No.: EMAIL Address: JeffPAllen@Eaton.com Fax No.: D. PROPERTY OWNER(S) (if different than well owner/applicant) Name and Title: Same as the well owner Company Name Mailing Address: City: State: Zip Code: County: Day Tele No.: Cell No.. EMAIL Address: Fax No.. E. PROJECT CONTACT (Typically Environmental Consulting/Engineering Firm) Name and Title: Bilgen Yuncu, Project Manager Company Name Draper Aden Associates (DAA) Mailing Address: 114 Edinburgh South Drive Suite 200 City: Cary State: NC Zip Code: 27513 County: Wake Day Tele No.: 919-582-7267 Cell No.: EMAIL Address: byuncu@daa.com Fax No.: F. PHYSICAL LOCATION OF WELL SITE (1) Facility Name & Address: Eaton Corporation 2564 Durham Road City: Roxboro County: Person Zip Code: 27573 (2) Geographic Coordinates: Latitude**: 36 ° 21 ' 34 " or Longitude**: 78 ° 59 ' 11.24 " or Reference Datum: Accuracy: Method of Collection: Google Maps **FOR AIR INJECTION AND AQUIFER TEST WELLS ONLY: A FACILITY SITE MAP WITH PROPERTY BOUNDARIES MAY BE SUBMITTED IN LIEU OF GEOGRAPHIC COORDINATES. G. TREATMENT AREA ° ° Land surface area of contaminant plume: 810,000 square feet Land surface area of inj. well network: 1,500 square feet (< 10,000 ft2 for small-scale injections) Percent of contaminant plume area to be treated: <5% (must be < 5% of plume for pilot test injections) Deemed Permitted GW Remediation NOI Rev. 2-17-2020 Page 2 H. INJECTION ZONE MAPS — Attach the following to the notification. (1) Contaminant plume map(s) with isoconcentration lines that show the horizontal extent of the contaminant plume in soil and groundwater, existing and proposed monitoring wells, and existing and proposed injection wells; and (2) Cross-section(s) to the known or projected depth of contamination that show the horizontal and vertical extent of the contaminant plume in soil and groundwater, changes in lithology, existing and proposed monitoring wells, and existing and proposed injection wells. (3) Potentiometric surface map(s) indicating the rate and direction of groundwater movement, plus existing and proposed wells. DESCRIPTION OF PROPOSED INJECTION ACTIVITIES AT THE SITE — Provide a brief narrative regarding the cause of the contamination, and purpose, scope, goals of the proposed injection activity: DAA will inject EOS Pro (emulsified vegetable oil) and BAC-9 (bioaugmentation culture) supplied by EOS Remediation, LLC to stimulate reductive dechlorination of PCE and associated daughter products in deep aquifer source zone. Two wells will be installed in partially weathered bedrock (PWR)/competent bedrock. Each well will be intended to be screened from 30 to 40 ft bls to inject in the PWR/bedrock zone. However, the screened interval of the proposed two wells will be adjusted based on site geology. The estimated total volume of amendments and dilution water is about 1,590 gallons and chase water is 1,900 gallons. The target flow rate at each point is between 0.5 and 1 gallon per minute (gpm) which was estimated from previous injection activities (i.e., field -observed injection rates and subsequent performance monitoring). Amendment will be injected in up to two injection locations for a total flow rate between 0.5 and 1 gpm resulting in an estimated injection duration of about six days. J. WELL CONSTRUCTION DATA (1) No. of injection wells: 2 Proposed Existing (provide NC Well Construction Record (GW-1) for each well) (2) Appx. injection depths (BLS): — 35 ft bls for proposed wells (3) For Proposed wells or Existing wells not having GW-ls, provide well construction details for each injection well in a diagram or table format. A single diagram or line in a table can be used for multiple wells with the same construction details. Well construction details shall include the following (indicate if construction is proposed or as -built): (a) Well type as permanent, Geoprobe/DPT, or subsurface distribution infiltration gallery (b) Depth below land surface of casing, each grout type and depth, screen, and sand pack (c) Well contractor name and certification number Well ID Installation Date PVC Riser (Casing) (ft bls) PVC Screen Interval (ft bls) Grout (ft bls) Bentonite (ft bls) Sand Pack (ft bls) Well Type Well Contractor IW-27B and IW-28B Proposed 0 - 30 30-40 0-23 23-28 28-40 Peiinanent TBD Deemed Permitted GW Remediation NOI Rev. 2-17-2020 Page 3 K. INJECTION SUMMARY NOTE: Only injectants approved by the epidemiology section of the NC Division of Public Health, Department of Health and Human Services can be injected. Approved injectants can be found online at http ://deq.nc.gov/about/divisions/water-resources/water-resources-permits/wastewater-branch/ground-water- protection/ground-water-approved-injectants. All other substances must be reviewed by the DHHS prior to use. Contact the UIC Program for more info if you wish to get approval for a different additive. However, please note it may take 3 months or longer. If no injectants are to be used use N/A. Injectant: EOS PRO Total Amt. to be injected (gal)/event: 265 Injectant: BAC-9 Total Amt. to be injected (gal)/event: 1 Injectant: Water Total Amt. to be injected (gal)/event: 3,225 Injectant: Total Amt. to be injected (gal)/event: Injectant: Total Amt. to be injected (gal)/event: Total Amt. to be injected (gaVevent): 3,491 No. of separate injection events:1 Total Amt. to be injected (gal): 3,491 Source of Water (if applicable): Hydrant on site L. MONITORING PLAN — Describe below or in separate attachment a monitoring plan to be used to determine if violations of groundwater quality standards specified in Subchapter 02L result from the injection activity. Baseline sampling will be conducted after two injection wells are installed and developed, prior to the injections. Each newly installed injection well pair will be sampled for Volatile Organic Compounds (VOCs). One monitoring well (MW-52D) near the injection area will also be sampled for VOCs, total organic carbon (TOC), sulfate, nitrate, total and dissolved iron and manganese, alkalinity, methane/ethane/ethene (MEE) and molecular biological tools (MBTs) . Approximately three months following the injection test, monitoring well MW-52D will be sampled for VOCs, TOC, sulfate, nitrate, total and dissolved iron and manganese, alkalinity, MEE and MBTs. One newly installed injection well will also be sampled for VOCs. Prior to sampling, water levels will be gauged at each of the wells. The wells selected for sampling will then be purged with a peristaltic pump and one -time -use new tubing using low -flow purging and sample collection procedures. During well purging, the water quality indicator parameters pH, temperature, dissolved oxygen (DO), oxidation-reduction potential (ORP), conductivity, and turbidity will be measured at three to five-minute intervals until these parameters stabilize within specific ranges. Following purging, groundwater samples will be collected and submitted to a North Carolina certified laboratory for VOCs by EPA8260D, TOC by SM 5310B, alkalinity by SM 2320B, nitrate by HACH 10206, sulfate by EPA 9056A, total and dissolved iron and manganese by EPA 6010D, and MEE by RSK 175 and to Microbial Insights, Inc. in Knoxville, TN for MBTs by CENSUS analyses. Deemed Permitted GW Remediation NOI Rev. 2-17-2020 Page 4 M. SIGNATURE OF APPLICANT AND PROPERTY OWNER Well Owner/Applicant: "I hereby cert, under penalty of law, that I am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties, including the possibility of fines and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related appurtenances in accordance with the 15A NCAC 02CO200 Rules." f cant Jeffrey Allen, Environmental, Health, Safety and Security Manager Print or Type Full Name and Title Property Owne (if the property is not owned by the Well Owner/Applicant): "As owner of the property on which the injection well(s) are to be constructed and operated, I hereby consent to allow the applicant to construct each injection well as outlined in this application and agree that it shall be the responsibility of the applicant to ensure that the injection well(s) conform to the Well Construction Standards (15,4 NCAC 02C . 0200). " "Owner" means any person who holds the fee or other property rights in the well being constructed. A well is real property and its construction on land shall be deemed to vest ownership in the land owner, in the absence of contrary agreement in writing. Same as the applicant Signature* of Property Owner (if different from applicant) Print or Type Full Name and Title *An access agreement between the applicant and property owner may be submitted in lieu of a signature on this form. Please send 1 (one) hard color copy of this NOI along with a copy on an attached CD or Flash Drive at least two (2) weeks prior to injection to: DWR — UIC Program 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone: (919) 707-9000 Deemed Permitted GW Remediation NOI Rev. 2-17-2020 Page 5 O O O O CC0 wCD CD D O Z � O 0 w 0 a_ a mr 0 m w w w z m w 0 a_ a N 0 N w 0 ASP H p\LT MW-11 M W— 45D IW 13 • GP—'2 IW-22B • I -19 IW-23A /IW-23B IW-4 IW_21 B ^ IW-1 IW-24B• • W BH—$w-1 D 1 I W-3y5 •1 '-�• BH—I� P� 1 GPiv6�• IW-1 GP-11 +GP — MW=5 • IW-16 W-12 •IW18 0 •Iw 6 IW 11 IW-10 w l > GP-7 • CONCRETE 1 15- 53 • TW-1,5 W 46 D IW-26B IW-25 GP-9 w MW-5 wTW-14 IO Z O O G�8 RECOVERY TRENCH TOOL ROOM TRANSFORMERS IW-20 M W— 47D M W— 47S THREE RIVERS ROOM GP-19 TRUCK SCALE (IN) GP-14 TRUCK EATO\ FACILITY [-` /-, A 1 I — LEGEND • SHALLOW MONITORING WELL LOCATION DEEP MONITORING WELL LOCATION O RECOVERY WELL LOCATION • TEMPORARY WELL LOCATION SITE BOUNDARY FENCE, CHAIN LINK WOODED AREA • 0 SAPROLITE/PWR INJECTION WELL LOCATION BEDROCK INJECTION WELL LOCATION (APPROXI MATE) PROPOSED BEDROCK INJECTION WELL LOCATION (APPROXIMATE) 70 140 SCALE IN FEET a Draper Aden Associates Engineering • Surveying • Environmental Services 114 Edinburgh South Drive, Suite 200 Cary, NC 27511 919-873-1060 Fax: 919-873-1074 www.daa.coin NC Finn License # C-0861 • Richmond, VA • Blacksburg, VA • Charlottesville, VA • Hampton Roads, VA • Fayetteville, NC • Northern Virginia • Virginia Beach, VA NOTES: 1) SITE PLAN BASED ON PLAT OF SURVEY COMPLETED BY HAMLETT-JENNINGS AND ASSOCIATES, DATED NOVEMBER 2010. EATON CORPORATION 2564 DURHAM ROAD ROXBORO, NORTH CAROLINA PROPOSED INJECTION PLAN FIGURE: 1 T:\Env-NC\CAD Files\Project Files\Eaton Corporation\Eaton Roxboro\Current Drawings\2022 Pilot ,dy.dwc O O O O O CC 0 w CO co N D O Z � O U w O a_ a >- mr 0 m w 0 U w 0 O 03 w z z 0 w O a_ a MW-42 WOODED 49.13 ACRES W-41 W-32 MW-21RD —40 WOODED WOODED w-22s 12,23,3 iiw23s iwa w-2as• • BH-842 1.3 BH—I GP�Q� • r ° TW- 4,1 AW- �N`10 A wz-S o-.11GP-9 GP-1 GP- MW-51 GP-18 I 14 W-1 GP-2 RW-4 • MW-39 MW-43A MW-438 4. TOOL ROOM .TRANSFORMERS 20 G¢8 1 RECOVERY TRENCH MW-2A B MW-47D MW-47S GP- U W-48D MW-3 B MW-38 MW-37D RW-1 rn p MW—SS#MW—SDMW— WOODED CONCRETE PARKING THREE RIVERS ROOM 5 TRUCK �`•` SCALE 0_10TRU SCALE (OUT) EATON FACILITY J 1W-51D ¢GP-13 A INTENORTH RCEPTOR 47-� GP-4 GP-5 ¢ PIT MW-49D MW-5°S011 SOD �� ASPHALT PARKING ASPHALT RW-2 MW-23* MW-31D RV/-5 ,MW-36 MW-315 NW-33SoMW-33D MW-34, ASPHALT L 20' SANITARY SEWER EASEMENT 4 0 TO ROXBORO - (Log sn) avoa rivHana « rivHana of LEGEND • SHALLOW MONITORING WELL LOCATION • DEEP MONITORING WELL LOCATION O RECOVERY WELL LOCATION • TEMPORARY WELL LOCATION EXISTING SSD SUMP APPROXIMATE SSD TRENCH LOCATION SITE BOUNDARY • SAPROLITE / PWR INJECTION WELL LOCATION BEDROCK INJECTION WELL LOCATION (APPROXIMATE) PROPOSED BEDROCK INJECTION WELL LOCATION (APPROXIMATE) • — G— UNDERGROUND GAS LINE — PH— UNDERGROUND PHONE LINE — E— UNDERGROUND ELECTRIC LINE STORM WATER SYSTEM FENCE, CHAIN LINK WOODED AREA A - A' CROSS SECTION LINE 0 200 400 SCALE IN FEET a Draper Aden Associates Engineering • Surveying • Environmental Services 114 Edinburgh South Drive, Suite 200 Cary, NC 27511 919-873-1060 Fax: 919-873-1074 www.rlaa.com NC Firm License # C-0861 • Richmond, VA • Blacksburg, VA • Charlottesville, VA • Hampton Roads, VA • Fayetteville, NC • Northern Virginia • Virginia Beach, VA NOTES: 1) SITE PLAN BASED ON PLAT OF SURVEY COMPLETED BY HAMLETT-JENNINGS AND ASSOCIATES, DATED NOVEMBER 2010. EATON CORPORATION 2564 DURHAM ROAD ROXBORO, NORTH CAROLINA CROSS SECTION INDEX FIGURE: 2 T:\Env-NC\CAD Files\Project Files\Eaton Corporation\Eaton Roxboro\Current Drawings\2022 Pilot ,dy.dwc O 0 0 CC0 w CD CD D O Z � O w 0 a_ a mm 0 w 0 w w w z z m 0 w 0 a_ a a 0 a N 0 w N L LEGEND A WEST 670 — 660 — 650 — 640 — 630 — 620 — 610 — 600 — 590 — 580 — 570 B-B' 0 tf) N V co W EATON PLANT SC � II SLT 646.1 —L i26---------------- TD=12.5' -- /•---__---�----FSfi3—s MVB 1 / i 1 1 PCE= 0.82 Fp=35.0' • MVB TD=40.0' ---------------- I I I I II I I PCE= 63,300 TD=30.0' co 0 LC) Lf) TD=10.0' PCE= 7.6 TD=30.0' PCE= 1.8 01/ MVB A' EAST — 670 — 660 — 650 — 640 — 630 — 620 — 610 — 600 — 590 — 580 SC = SILTY CLAY, MOSTLY FILL MATERIAL. MAY INCLUDE SOME IN -SITU CLAYEY COIL. SLT = (SAPROLITE) - SANDY AND CLAYEY SILT WITH WEATHERED ROCK FRAGMENTS AND IRON AND MANGANESE OXIDE PRECIPITATION ALONG FRACTURES. PWR = (SAPROLITE) - PARTIALLY WEATHERED BEDROCK. WEATHERED TO SANDY -CLAYEY SILT ALONG NUMEROUS FRACTURES AND SOFT ENOUGH TO PENETRATE WITH AN AUGER. MVB = METAVOLCANIC BEDROCK, FOLIATED FELSIC METAVOLCANICS Y 613.44 BEDROCK WELL WATER LEVEL DECEMBER 20201 INTERBEDDED WITH HIGHLY SLICEOUS, FLOW -BANDED APPROXIMATE WATER TABLE BEDROCK METAVOLCANICS. ------ LITHOLOGY FOR MW-45D, MW-51 D, AND MW-52D BASED ON DRILLERS = WELL SCREEN LOGS ONLY. V 622.30 SAPROLITE WELL WATER LEVEL DECEMBER 2021 TETRACHLOROETHENE (PCE) CONCENTRATION IN PCE= 29.70 MICROGRAMS PER LITER (ug/L) DECEMBER 2021 570 ESTIMATED EXTENT OF PCE IN GROUNDWATER (ug/L) PCE NCAC 2L STANDARD - 0.7 ug/L EXISTING INJECTION POINT(S) PROJECTED ONTO CROSS SECTION WITH TOTAL DEPTHS PROPOSED INJECTION POINT(S) PROJECTED ONTO CROSS SECTION WITH TOTAL DEPTHS a Draper Aden Associates Engineering • Surveying • Environmental Services 114 Edinburgh South Drive, Suite 200 Cary, NC 27511 919-873-1060 Fax: 919-873-1074 www.daa.coin NC Finn License # C-0861 • Richmond, VA • Blacksburg, VA • Charlottesville, VA • Hampton Roads, VA • Fayetteville, NC • Northern Virginia • Virginia Beach, VA NOTES: HORIZONTAL SCALE: 1" = 150' VERTICAL SCALE: 1" = 15' VERTICAL EXAGGERATION = 10 SITE PLAN BASED ON PLAT OF SURVEY COMPLETED BY HAMLETT-JENNINGS AND ASSOCIATES, DATED NOVEMBER 2010. EATON CORPORATION 2564 DURHAM ROAD ROXBORO, NORTH CAROLINA CROSS SECTION A - A' FIGURE: 3 T:\Env-NC\CAD Files\Project Files\Eaton Corporation\Eaton Roxboro\Current Drawings\2022 Pilot ,dy.dwc 0 N N w 0 TO ROXBORO + LEGEND SHALLOW MONITORING WELL LOCATION DEEP MONITORING WELL LOCATION 18f RECOVERY WELL LOCATION ▪ TEMPORARY WELL LOCATION 642.73 NG 0 PROPOSED BEDROCK INJECTION WELL LOCATION (APPROXIMATE) SITE BOUNDARY FENCE, CHAIN LINK WOODED AREA GROUNDWATER CONTOUR (ESTIMATED) GROUNDWATER ELEVATION (FEET ABOVE MEAN SEA LEVEL) GROUNDWATER FLOW DIRECTION (ESTI MATED) NOT GAUGED 250 500 SCALE IN FEET a Draper Aden Associates r7 Engineering • Surveying • Environmental Services 114 Edinburgh South Drive, Suite 200 Cary, NC 27511 919-873-1060 Fax: 919-873-1074 www.daa.com NC Firm License # C-0861 • Richmond, VA • Blacksburg, VA • Charlottesville, VA • Hampton Roads, VA • Fayetteville, NC • Northern Virginia • Virginia Beach, VA NOTES: 1) SITE PLAN BASED ON PLAT OF SURVEY COMPLETED BY HAMLETT-JENNINGS AND ASSOCIATES, DATED NOVEMBER 2010. EATON CORPORATION 2564 DURHAM ROAD ROXBORO, NORTH CAROLINA SHALLOW GROUNDWATER POTENTIOMETRIC SURFACE MAP DECEMBER 2021 FIGURE: 4 T:\Env-NC\CAD Files\Project Files\Eaton Corporation\Eaton Roxboro\Current Drawings\2022 Pilot ,dy.dwc O O O O O CC 0 w 0] (O N D O Z � O 0 w O a_ a CC I— � w 0 >- mr 0 m w O w 0 U 40 w Z m 0 w O a_ a 13 ACRES Nw-11$i 62 GP- EO 1 +ern, BH-S aBN NW-47S 64735 NW 475 EATON FACIU OP-14 SCALE TRUCK (OUT) CouT) �N6-518 +1i-13 NORTH INTERCEPTOR GP Q pT 3, ASPHALT PPARKINGeoe TO ROXBORO + LEGEND SHALLOW MONITORING WELL LOCATION • DEEP MONITORING WELL LOCATION 18f RECOVERY WELL LOCATION ▪ TEMPORARY WELL LOCATION PROPOSED BEDROCK INJECTION WELL LOCATION (APPROXIMATE) SITE BOUNDARY FENCE, CHAIN LINK WOODED AREA �— GROUNDWATER CONTOUR (ESTIMATED) 622.70 0 GROUNDWATER ELEVATION (FEET ABOVE MEAN SEA LEVEL) GROUNDWATER FLOW DIRECTION (ESTI MATED) 250 500 SCALE IN FEET a Draper Aden Associates r7 Engineering • Surveying • Environmental Services 114 Edinburgh South Drive, Suite 200 Cary, NC 27511 919-873-1060 Fax: 919-873-1074 www.daa.com NC Firm License # C-0861 • Richmond, VA • Blacksburg, VA • Charlottesville, VA • Hampton Roads, VA • Fayetteville, NC • Northern Virginia • Virginia Beach, VA NOTES: 1) SITE PLAN BASED ON PLAT OF SURVEY COMPLETED BY HAMLETT-JENNINGS AND ASSOCIATES, DATED NOVEMBER 2010. EATON CORPORATION 2564 DURHAM ROAD ROXBORO, NORTH CAROLINA DEEP GROUNDWATER POTENTIOMETRIC SURFACE MAP DECEMBER 2021 FIGURE: 5 T:\Env-NC\CAD Files\Project Files\Eaton Corporation\Eaton Roxboro\Current Drawings\2022 Pilot ,dy.dwc to CC I— W Y W EATON FACILITY w z z m 0 w O Lr a TO ROXBORO + LEGEND SHALLOW MONITORING WELL LOCATION DEEP MONITORING WELL LOCATION RECOVERY WELL LOCATION TEMPORARY WELL LOCATION PROPOSED BEDROCK INJECTION WELL LOCATION (APPROXIMATE) SITE BOUNDARY FENCE, CHAIN LINK WOODED AREA 247 J <0.16 0 ESTIMATED LATERAL EXTENT OF TETRACHLOROETHENE (PCE) IN GROUNDWATER (0.7 fag/L) (DASHED WHERE INFERED) PCE CONCENTRATIONS SHOWN IN MICROGRAMS PER LITER ( fag/L) ESTIMATED CONCENTRATION CONSTITUENT NOT DETECTED ABOVE LABORATORY REPORTING LIMIT 250 500 SCALE IN FEET a Draper Aden Associates Engineering • Surveying • Environmental Services 114 Edinburgh South Drive, Suite 200 Cary, NC 27511 919-873-1060 Fax: 919-873-1074 www.daa.coin NC Finn License # C-0861 • Richmond, VA • Blacksburg, VA • Charlottesville, VA • Hampton Roads, VA • Fayetteville, NC • Northern Virginia • Virginia Beach, VA NOTES: 1) SITE PLAN BASED ON PLAT OF SURVEY COMPLETED BY HAMLETT—JENNINGS AND ASSOCIATES, DATED NOVEMBER 2010. 2) DATA FROM SAMPLES COLLECTED DECEMBER 2020. 3) DATA FROM RECOVERY WELLS NOT USED. 4) TETRACHLOROETHENE NCAC 2L STANDARD — 0.7 pg/L. EATON CORPORATION 2564 DURHAM ROAD ROXBORO, NORTH CAROLINA PCE ISOCONCENTRATION MAP SHALLOW ZONE DECEMBER 2021 FIGURE: 6 T:\Env-NC\CAD Files\Project Files\Eaton Corporation\Eaton Roxboro\Current Drawings\2022 Pilot Study.dwg O O O O 0 CC0 w O m co N D O Z 0 O W 0 a_ 0) CC I— W Y u_ 0 W z z m W 0 a_ 040 49.13 ACRES 35 -ri 0.7 GP-2 a48 <040 ATE PARING TOOL ROOM ERS THREE ROOM EATON FACILITY GPI NORiH /•� ���GP-5 INTERCEPTOR PIT //7 / // RW-3 MW-3S /7/�p 1,000 30 MW- b'Wy� 62 9 RW-2 ... MW-44C I <040 / MW-23e / <040' �Wr_/ MW-31 4$71qp MW-31S MW-33S0MW-33O SOUTH 2 ASPHALT PARKING • 20' SANITARY SEWER EASEMENT MW-34, TO ROXBORO + LEGEND SHALLOW MONITORING WELL LOCATION DEEP MONITORING WELL LOCATION 18f RECOVERY WELL LOCATION ▪ TEMPORARY WELL LOCATION PROPOSED BEDROCK INJECTION WELL • LOCATION (APPROXIMATE) SITE BOUNDARY FENCE, CHAIN LINK WOODED AREA ESTIMATED LATERAL EXTENT OF TETRACHLOROETHENE (PCE) IN GROUNDWATER (0.7 fag/L) (DASHED WHERE INFERED) 475 MICROGRAMS PER LITER ( pg/L) J ESTIMATED CONCENTRATION <0.16 CONSTITUENT NOT DETECTED ABOVE 0 PCE CONCENTRATIONS SHOWN IN LABORATORY REPORTING LIMIT 250 500 SCALE IN FEET a Draper Aden Associates Engineering • Surveying • Environmental Services 114 Edinburgh South Drive, Suite 200 Cary, NC 27511 919-873-1060 Fax: 919-873-1074 www.daa.com NC Finn License # C-0861 • Richmond, VA • Blacksburg, VA • Charlottesville, VA • Hampton Roads, VA • Fayetteville, NC • Northern Virginia • Virginia Beach, VA NOTES: 1) SITE PLAN BASED ON PLAT OF SURVEY COMPLETED BY HAMLETT—JENNINGS AND ASSOCIATES, DATED NOVEMBER 2010. 2) DATA FROM SAMPLES COLLECTED DECEMBER 2020. 3) DATA FROM RECOVERY WELLS NOT USED. 4) TETRACHLOROETHENE NCAC 2L STANDARD — 0.7 pg/L. EATON CORPORATION 2564 DURHAM ROAD ROXBORO, NORTH CAROLINA PCE ISOCONCENTRATION MAP DEEP ZONE DECEMBER 2021 FIGURE: 7 T:\Env-NC\CAD Files\Project Files\Eaton Corporation\Eaton Roxboro\Current Drawings\2022 Pilot Study.dwg EOS PRO EOS Remediation, LLC SAFETY DATA SHEET Section 1: Identification Product Name: Chemical Description: Manufacturer: EOS Pro Mixture; vegetable oil emulsion EOS Remediation PO Box 14266 Research Triangle Park NC 27709 (P): 919-873-2204 www.eosremediation.com Recommended Use: Groundwater bioremediation (environmental applications) Restricted Use: Not for human consumption. 24-Hour Emergency Contact: ChemTel: United States (P): 800-255-3924 ChemTel: International (P): 813-248-0585 Section 2: Hazard(s) Identification Hazard Classification: Signal Word: Hazard Statement(s): Pictograms: Precautionary Statement(s): Irritant (skin and eye) Warning Potential eye and skin irritant. Not for human consumption. Do not store near excessive heat or oxidizers. Avoid contact with eyes and skin. Wear protective gloves and eye protection. Section 3: Composition/Information on Ingredients Common Name(s) Soybean Oil CAS NO. % by Weight Food Grade Emulsifiers Trade Secret1,2 8001-22-7 60 Soluble Substrates (glycerol) Trade Secret1,2 Water 111-03-5 10 56-81-5 4 7732-18-5 26 1—The precise composition of this product is proprietary information. A more complete disclosure will be provided to a physician in the event of a medical emergency. 2 — The soluble substrates and emulsifiers are generally recognized as safe for food contact. EOS Remediation, LLC EOS PRO SAFETY DATA SHEET Section 4: First -Aid Measures Routes of Exposure Inhalation Eye Contact Skin Contact Ingestion Emergency First -Aid Procedures Remove to fresh air. Flush with water for 15 minutes; if irritation persists see a physician. Wash with mild soap and water. Product is non -toxic. If nausea occurs, induce vomiting and seek medical attention. Section 5: Fire -Fighting Measures Extinguishing Media: CO2, foam, dry chemical Note: Water, fog and foam may cause frothing and spattering. Special Fire Fighting Procedures: Wear self-contained breathing apparatus and chemical resistant clothing. Use water spray to cool fire exposed containers. Fire Hazard(s): Burning will cause oxides of carbon. Section 6: Accidental Release Measures Personal Precautions: Emergency Procedures: Methods & Materials used for Containment: Cleanup Procedures: Avoid contact with eyes and skin. Do not consume. N/A Compatible granular absorbent Spread compatible granular absorbent over spill area and sweep using broom and pan; dispose in appropriate receptacle. Clean area with water. Section 7: Handling and Storage Safe Handling & Storage: Other Precautions: Do not store near excessive heat or oxidizers. Consumption of food and beverages should be prevented in work area where product is being used. After handling product, always wash hands and face thoroughly with soap and water before eating, drinking, or smoking. Section 8: Exposure Controls/Personal Protection Exposure Limits OSHA PEL: NE ACGIH TLV: NE NIOSH REL: NE Personal Protective Measures Respiratory Protection: Not normally required. P95 respirator if aerosols might be generated. Hand Protection: Protective gloves are recommended Eye Protection: Recommended Engineering Measures: Local exhaust ventilation if aerosols are generated Hygiene Measures: Wash promptly with soap & water if skin becomes irritated from contact. Other Protection: Wear appropriate clothing to prevent skin contact. EOS Remediation, LLC 2 EOS PRO SAFETY DATA SHEET Section 9: Physical and Chemical Properties Appearance: White Liquid Explosive Limits: NE Odor: Vegetable Oil Vapor Pressure: NE Odor Threshold: NE Vapor Density: Heavier than air pH: 6.0-7.0 (su) Relative Density: 0.96-0.98 Melting Point/Freezing Point: Liquid at room temperature Solubility: Dispersible Boiling Point: 212°F (100°C) Partition coefficient: NE Flash Point: >300°F (149°C) Auto -ignition Temperature: NE Evaporation Rate: NE Decomposition Temperature: N/A Flammability (solid, gas): NE Viscosity: 500-1500 cP NE — Not Established Section 10: Stability and Reactivity Stability: Incompatibility: Stable Strong acids and oxidizers Hazardous Decomposition Products: Thermal decomposition may produce oxides of carbon Hazardous Reactions/Polymerization: Will not occur Conditions to Avoid: None known Section 11: Toxicological Information Likely Routes of Exposure: Ingestion, dermal and eye contact Signs and Symptoms of Exposure: None known Health Hazards Acute: Potential eye and skin irritant Chronic: None known Carcinogenicity NTP: No IARC: OSHA: No No Section 12: Ecological Information (non -mandatory) There is no data on the ecotoxicity of this product. Section 13: Disposal Considerations (non -mandatory) Waste Disposal Methods: Dispose of according to Federal and local regulations for non -hazardous waste. Recycle, if practical. EOS Remediation, LLC 3 EOS PRO SAFETY DATA SHEET Section 14: Transport Information (non -mandatory) The product is not covered by international regulation on the transport of dangerous goods. No transport warning required. Section 15: Regulatory Information (non -mandatory) N/A Section 16: Other Information Date of Preparation: 29 May 2014 Last Modified Date: 27 June 2019 The information contained herein is based on available data and is believed to be correct. However, EOS Remediation, LLC makes no warranty, expressed or implied, regarding the accuracy of this data or the results to be obtained thereof. This information and product are furnished on the condition that the person receiving them shall make his/her own determination as to the suitability of the product for his/her particular purpose. EOS Remediation, LLC 4 E S EOS Remediation, LLC BAC-9 SAFETY DATA SHEET Section 1: Identification Product Name: BAC-9 aka SDC-9 Chemical Description: Manufacturer: Non -toxic, naturally occurring, non-pathogenic, non -genetically altered anaerobic microbes in a water -based medium Aptim 17 Princess Road Lawrenceville, NJ 08648 609-895-5340 Recommended Use: Groundwater bioremediation (environmental applications) Restricted Use: Not for human consumption. 24-Hour Emergency Contact: CHEMTREC (P): 800-424-9300 Section 2: Hazard(s) Identification Hazard Classification: Signal Word: Hazard Statement(s): Irritant (skin and eye) Warning Potential eye and skin irritant in hypersensitive humans. Pictograms: Precautionary Statement(s): Not for human consumption. Avoid contact with eyes and skin. Wear protective gloves and eye protection. Section 3: Composition/Information on Ingredients Common Name(s) Microbial consortium in water (comprised of microorganism of the genera Dehalococcoides) CAS NO. N/A by Weight 100 Section 4: First -Aid Measures Routes of Exposure Inhalation Eye Contact Skin Contact Ingestion Emergency First -Aid Procedures Get medical attention if allergic symptoms develop. Flush eyes with plenty of water for at least 15 minutes.. Get medical attention if irritation occurs. N/A Thoroughly rinse mouth with water. Do not induce vomiting unless directed to do so by medical personnel. Get immediate medical attention. Section 5: Fire -Fighting Measures Extinguishing Media: I CO2, foam, dry chemical EOS Remediation, LLC BAC-9 Special Fire Fighting Procedures: Fire Hazard(s): None None SAFETY DATA SHEET Section 6: Accidental Release Measures Personal Precautions: Emergency Procedures: Avoid contact with skin or eyes. N/A Methods & Materials used for Containment: Cleanup Procedures: Compatible granular absorbent Spread compatible granular absorbent over spill area and sweep using broom and pan; dispose in appropriate receptacle. Clean area with water. Section 7: Handling and Storage Safe Handling & Storage: Other Precautions: Use personal protective equipment recommended in Section 8. Keep containers tightly closed in a cool, well -ventilated area. The DHC microbial consortium can be supplied in stainless steel kegs designed for maximum working pressure of 130 psi and equipped with pressure relief valves. The kegs are pressurized with Nitrogen up 15 psi. Do not exceed pressure of 15 psi during transfer of DHC microbial consortium from kegs. Do not open keg if content of the keg is under pressure. BAC-9 may be stored for up to 3 weeks at a temperature range of 2-4°C without aeration. Avoid freezing. Section 8: Exposure Controls/Personal Protection Exposure Limits OSHA PEL: NE ACGIH TLV: NE NIOSH REL: NE Personal Protective Measures Respiratory Protection: Not normally required. N95 respirator if aerosols might be generated. Hand Protection: Protective gloves are recommended. Eye Protection: Recommended. An eyewash station in the work area is recommended. Engineering Measures: Local exhaust ventilation if aerosols are generated Hygiene Measures: Wash promptly with soap & water following skin contact. Other Protection: Wear appropriate clothing to prevent skin contact. EOS Remediation, LLC 2 BAC-9 SAFETY DATA SHEET Section 9: Physical and Chemical Properties Appearance: Light greenish murky liquid Explosive Limits: N/A Odor: Musty Vapor Pressure: 24 mm Hg Odor Threshold: N/A Vapor Density: N/A pH: 6.0-8.0 Relative Density: 0.9-1.1 Melting Point/Freezing Point: 0°C Solubility: Soluble Boiling Point: 100°C Partition coefficient: NE Flash Point: N/A Auto -ignition Temperature: N/A Evaporation Rate: 0.9-1.1 Decomposition Temperature: N/A Flammability (solid, gas): N/A Viscosity: NE Section 10: Stability and Reactivity Stability: Incompatibility: Stable Water -reactive materials Hazardous Decomposition Products: None Hazardous Reactions/Polymerization: None Conditions to Avoid: None Section 11: Toxicological Information Routes of Exposure: Ingestion, Eye Contact Signs and Symptoms of Exposure: Ingestion of large quantities may result in abdominal discomfort including nausea, vomiting, cramps, diarrhea, and fever. Skin may become irritated upon prolonged contact. Hypersensitive individuals may experience allergic reactions. May cause eye irritation unless immediately rinsed. Health Hazards Acute: Irritation of the skin or eyes. Ingestion may result in abdominal discomfort. Chronic: None Carcinogenicity NTP: No IARC: No OSHA: No Section 12: Ecological Information (non -mandatory) Ecotoxicity: this material will degrade in the environment EOS Remediation, LLC 3 BAC-9 SAFETY DATA SHEET Section 13: Disposal Considerations (non -mandatory) Waste Disposal Methods: Dispose of according to Federal and local regulations for non -hazardous waste. Recycle, if practical. Section 14: Transport Information (non -mandatory) The product is not covered by international regulation on the transport of dangerous goods. No transport warning required. Section 15: Regulatory Information (non -mandatory) N/A Section 16: Other Information Date of Preparation: Last Modified Date: 15 August 2014 12 August 2019 The information contained herein is based on available data and is believed to be correct. However, EOS Remediation, LLC makes no warranty, expressed or implied, regarding the accuracy of this data or the results to be obtained thereof. This information and product are furnished on the condition that the person receiving them shall make his/her own determination as to the suitability of the product for his/her particular purpose. EOS Remediation, LLC 4