HomeMy WebLinkAboutWQ0043471_Application (FTSE)_20220511DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 06-21 & SUPPORTING DOCUMENTATION Application NumberMQW 1 941 / (to be completed by DWR) All items must be completed or the application will be returned APPLICANT INFORMATION: I. Applicant's name: Franklin County Public Utilities (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State/County D Municipal 3. Signature authority's name. Christopher Doherty per 15A NCAC 02T ,0106113) Title: Public_l `tilities Director 4. Applicant's mailing address: 1630 US 1 Highway City: Youngsville State: NC Zip: 27549-_ 5. Applicant's contact information: Phone number: (919) 556-6177 Email Address: cdoherty@franklincountync.us ❑ Other NC Dept of Environmental Quality MAY 11 2022 Raleigh Regional Office II. PROJECT INFORMATION:37 l_ Project name; Maple Ridge ,-./1001111'- 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: , For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Franklin 4. Approximate Coordinates (Decimal Degrees): Latitude: 37.075423Q Longitude:-78.4309I2Q 5. Parcel ID (if applicable): 029208 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Tyler E. Probst License Number: 051536 Firm: McAdams Mailing address: 2905 Meridian Pkwy City: Durham State: NC Zip: 27713- Phone number: (919) 361-5000 Email Address: probstta mcadamsco.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Franklin County Wastewater Treatment Plant Permit Number: NC 0069311 Owner Name: Franklin County Public Utilities V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. Permit Number(s): WQ 2_ Downstream (Receiving) Sewer Information: 10 inch l7 Gravity ® Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00I79 Owner Name(s): Franklin County Public Utilities FORM: FTA 06-21 Page 1 of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑ No ®NIA 2. if the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreemem (FORN.11 DE\' I been attached? ❑ Yes ❑ No ® NA 3. If the Applicant is a Home/Property Owners' Association, has an HOAFPOA Operational Agreement (FORM: HOA1 and supplementary documentation as required by I5A NCAC 02T.01 15(c) been attached? ❑ Yes ❑ No ®N?A 4. Origin of wastewater: (check all that apply): Residential (Individually Owned) ❑ Retail (stores, centers, malls) ® Residential (Leased) ❑ Retail with food preparationfservice ❑ School / preschool / day care ❑ Medical . dental / veterinary facilities ❑ Food and drink facilities ['Church ❑ Businesses / offices / factories ❑ Nursing Home ❑ Car Wash ❑ Hotel andlor Motels ❑ Swimming Pool/Clubhouse ❑ Swimming PoollFilter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic % Commercial % Industrial (See 1 5A NCAC 02T .0I 03i 201) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .01 I4i fi? ❑ Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(t)) Daily Design Flow ".° No. of Units Flow Single Family (3 BR)* 250 gal/day 5! 12,750 GPD Townhome * 250 gal/day 86 21,500 GPD Single Family (4 BR)* 334 gal/day 33 11,022 GPD gal/ GPD gal/ GPD *Per Franklin County Utility Allocation gal/ GPD Total 45,272 GPD a See I SA NCAC 02T _01141bk id), { ell 11 and le 1 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per I5A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC .2'r.01 I4] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project; GPD (per 15A NC AC .01 I4.) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station.'Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: __.. _ Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sellers): 1. Summarize gravity sewer to be permitted Size (inches) Length (feet) Material 8 1,145 SDR 35 PVC 8 840 SDR 26 PVC 8 3,561 C900 DR 18 PVC 8 128 401 Protect° DIP ➢ Section II & ili of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable)— 02T .0305 & MDC (Puntp-Stations,'Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Maple Ridge Pump Station by LKC Engineering under separate application. 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station: millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): _ gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.1.b. ❑ Grinder Pump D Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAc LT .(13105(19( I): D Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - I5A NCAC 02T.0305(h)(1)(B)1 ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 IX. SETBACKS & SEPARATIONS (02B .0200 & 15A NCAC 02T .0305(f)): Does the project comply with all separationslaltematives found in 15A NCAC 02T:0305{f) & lgl? 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* ❑ Yes ❑ No Separation Required Storm sewers and other utilities not listed below (vertical) 2Water mains (vertical - water over sewer preferred, including in benched trenches) 2Water mains (horizontal) 18 inches 18 inches I0 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) **Any other stream, Iake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. Any building foundation (horizontal) 50 feet 10 feet 5 feet Any basement (horizontal) Top slope of embankment or cuts of 2 feet or more vertical height Drainage systems and interceptor drains Any swimming pools Final earth grade (vertical) 10 feet 10 feet ➢ If noncompliance with 02T.0305(ft or 10. see Section X.1 of this application *I 5A NCAC 0?,T.0305(g) contains alternatives where separations in 02T.0?05 II cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC.Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A ➢ If no, please refer to 1 5A NCAC 18C.0906(t) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ NIA ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ See the Division's drf1 separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Tar Pamlico ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 028 .0200? ® Yes ❑ No ➢ This includes Trout Buffered Streams per 15A NCAC 2B.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits D Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.00105, cj(6j, directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" ❑ Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Puma Stalioni an4 Force Mains (latest versiottl, and the Gravity Sewer Minimum Design Criteria I la esi version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requirinE a variance approval may be subject to loneer review times. For projects requirinE two or more variances or where the variance is determined by the Division to be a sienificant portion of the project, the full technical review is required. 2. Professional Engineer's Certification: 1, Tyler E. Probst, PE , attest that this application for Maple Ridge (Professional Engineer's name from Application Item 111 1) (Project Name from Application Item 11.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity ' etiv r l latest. versk nl, and the Minimum Design Criteria for the Fast -Track Permitting of Purnp Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: +osittouspflij*,I ,`�N CAROB'•,*''. :`,,_0.�FtS6.ILJ. dived 71eby �- ProFist - ate: CS1 112.0 0 i,, 09: -0410' 1%SI C �',�`- .' ../ 3. Applicant's Certification per I5A NCAC 02T .0106(b): Christopher Doherty I, , attest that this application for Maple Ridge , (Signature Authority Name from Application Item 13 ) (Project Name from Application Item 111) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes I43-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 05-09-2022 FORM: FTA 06-21 Page 5 of 5 t1�1 MCADAMS LETTER OF TRANSMITTAL Date: May 9, 2022 HAND DELIVER To: NCDEQ Raleigh Regional Office 3800 Barrett Drive Re: Maple Ridge Sewer Permit Application Raleigh, North Carolina 27609 Job #: 2020110384 I am sending you the following items: ❑ Drawings ❑ Specifications ❑ Plans ❑ Letter ® Submittal LI Prints ❑ Statement of Qualifications ❑ Other QUANTITY UNIT DESCRIPTION 2 Copies FTSA Application NC Dept 1 Check $480.00 to NCDEQ of Environmental Qualit 2 Copies USGS tope Map Y 2 Copies Aerial Site Map Transmitted as checked below: ® For approval O For your use ❑ As requested ® For review + comment ❑ Other O Other Raleigh Regional Office Narrative: Please find the attached FTA for the onsite gravity sewer system for Maple Ridge. The project includes a total of 84 single family homes and 86 townhomes for a total estimated sewer flow of 45,272 gallons per day. There is a proposed public pump station and offsite force main that LKC Engineering has designed and gained approval for from Franklin County Utilities and they will submit as a separate permit application. Copy to: Signature: wpA.Ad Brad Rhinehalt, PE / ak Sr. Project Manager, Residential creating experiences through experience 2905 Meridian Parkway, Durham, NC 27713 / 919, 361. 5000 111 MCADAMS The John 8 McAdams Company nc 2905 Merid an Parkway Durham, NC27713 phone 919.361 5000 lax 919.361. 2269 license number: C 0293. C 187 wy.w mcadamsco corn MAPLE RIDGE USGS TOPO MAP CEDAR CREEK ROAD FRANKLIN COUNTY, NORTH CAROLINA PLAN INFORMATION PROJECT NO. GHK-2020110384 FILENAME USGS-MAP CHECKED BY TEP DRAWN BY SJB SCALE 1"=1000' DATE 08.10.2021