HomeMy WebLinkAboutGW1-2022-05428_Well Construction - GW1_20220426 220 Old Dairy Road
CATLIN Wilmington, NC 28405
Engineers and Scientists (910)452-5861
www.CatlinUSA.com
April 26, 2022
North Carolina Department of Environmental Quality
Division of Water Quality
Information Processing
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
Re: North Carolina Well Construction
NCDEQ-Annie Bowling Property
13109 N. Roxboro St.
Rougemont, North Carolina 27572
CATLIN Project No.: 221053
Incident No.: 17965
To Whom it May Concern,
CATLIN Engineers and Scientists (CATLIN) recently constructed three (3) monitoring
wells at the above referenced site. Attached to this letter are the completed North
Carolina Well Construction Records with associated Attachments for the site in
Rougemont, North Carolina.
If you have any questions or require additional information, please feel free to contact
us at (910) 726-1027.
Sincerely,
Benjamin J. Ashba P.G. Corey D. Futral, CWC
Project Manager Project Geologist
Enclosures
Well Construction Records, Well Logs, and Site Map
ENVIRONMENTAL CIVIL GEOTECHNICAL
Wilmington, NC I Raleigh, NC Washington, NC I Atlanta, GA I Charleston, SC
WELL CONSTRUCTION RECORD For InternalU, ONLY:
This form can be used for single or multiple wells
1.Well Contractor Information:
14.WATER ZONES
D.T. CHALMERS, JR. FROM I TO DESCRIPTION
Well Contractor Name ft ft
4146A ft ft
NC Well Contractor Certification Number 1S.INNER CASING OR TUBING(geothermal closed-loo
FROM TO DIAMETER THICKNESS MATERLll.
CATLIN Engineers and Scientists 0 ft. 5 ft. 2 irt.I Sch.40 1 PVC
Company Name 16.OUTER CASING for multi-cased wells OR LINER if applicable
FROM TO DIAMETER THICKNESS MATERIAL
2.Well Construction Permit#: NSA ft. ft. ;n.
List all applicable well permits(i.e.County,State, Variance,Injection,etc)
ft ft. in.
3.Well Use(check well use): 17.SCREEN
Water Supply Well: FROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL
❑Agricultural ❑Municipal/Public 5 fr. 20 ft. 2 in. SIOt.010 Sch.40 PVC
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ft. fr. in.
❑Industrial/Commercial ❑Residential Water Supply(shared) 18.GROUT
FROM TO MATERIAL EMPLACEMENT MET1IOD&AMOUNT
❑Irrigation 0 ft. 0.5 It. Portland Cement Surface Pour
Non-Water Supply Well:
®Monitoring ❑Recovery 0.5 ft. 4 It. Bent.Pellets Surface Pour
Injection Well: rt. rt.
❑Aquifer Recharge ❑Groundwater Rcmcdiation 19.SAND/GRAVEL PACK if a licable
❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO I MATERIAL EMPLACEMENTMETHOD
❑Aquifer Test ❑StonnwaterDrainage 4 ft. 20;0 Medium Sand Torpedo Said
❑Experimental Technology ❑Subsidence Control ft. ft.
20.DRILLING LOG attach additional sheets if necessar
❑Geothermal(Closed Loop) ❑Tracer FROM TO DESCRIPTION color,hardness soil/rock rmc,grain size,etc.
❑Geothermnal(Heating/Cooling Return) ❑Other(explain under#21 Remarks) ft. ft.
4.Date Well(s)Completed: 04/07/22 Well ID#: MW-01 ft. ft. -
ft. ft.
5a.Well Location:
ft ft
NCDEQ-Annie Bowling Property NA
Facility/Owner Name Facility ID#(if applicable)
ft.
13109 N. ROXBORO ST., ROUGEMONT,NC 27572
ft. IT
Physical Address,City,and Zip
21.REMARKS
WAKE NA
County Parcel Identification No.(PIN)
5b.Latitude and Longitude in degrees/minutes/seconds or decimal degrees: 22.Certification:
(ifwell field,one lat/longis sufficient)
36.220238 N -78.927265 w C 4125/2022
Signature of Certified Well Contractor Date
6.Is(are)the well(s): ®Permanent or ❑Temporary By signing this form,I hereby certify that the well(s)was(were)constructed in accordance with
15ANCAC 02C.0100 or 15ANCAC 02C.0200 Well Construction Standards and that a copy of
7.Is this a repair to an existing well: ❑Yes or ®No this record has been provided to the well owner.
If this is a repair,fill out known well construction information and explain the nature of
the repair under#21 remarks section or on the back of this form. 23.Site diagram or additional well details:
You may use the back of this page to pro-ride additional well site details or well
8.Number of wells constructed: construction details. You may also attach additional pages ifnecessary.
For multiple injection or non-water supply wells ONLYwith the same construction,you
can submit one form. SUBMITTAL INSTRUCTIONS
9.Total well depth below land surface: 20.0 (ft.) 24a.For All Wells: Submit this form within 30 days of completion of well
For multiple wells list all depths in different(example-3@200'and 2@1009 construction to the following:
10.Static water level below top of casing: 5.4 (ft.) Division of Water Resources,Information Processing Unit,
Ifwater level is above casing,use"+" 1617 Mail Service Center,Raleigh,NC 2 7 699-1 61 7
11.Borehole diameter: 8.25 (in.) 24b.For Injection Wells ONLY: In addition to sending the form to the
address in 24a above,also submit a copy of this form within 30 days of
12.Well construction method: HSA completion ofwell construction to the following:
(i.e.auger,rotanv,cable,directpush,etc.)
Division of Water Resources,Underground Injection Control Program,
FOR WATER SUPPLY WELLS ONLY: 1636 Mail Service Center,Raleigh,NC 27699-1636
13a.Yield(gpm) Method of test: 24c.For Water Svuuly&Injection Wells:
Also submit one copy of this form within 30 days of completion of well
13b.Disinfection type: Amount: construction to the comity health department of the county where constructed.
Adapted from Form GW-1 North Carolina Department of Environment and Natural Resources-Division of Water Resources Revised 2-22-2016
CATLIN
WELL LOG Engineers and Scientists
zzlos3 SHEET 1 OF 1
PROJECT NO.: 221053 STATE: NC COUNTY: WAKE LOCATION: ROUGEMONT
PROJECT: ANNIE BOWLING PROPERTY LOGGED BY: OLIVIA DAYNES WELL ID:
DRILLER: D.T. CHALMERS, JR. MW-01
NORTHING: 2021456 EASTING: 899082 CREW: PATRICK MCCAIN
SYSTEM: NCSP NAD 83 USft BORING LOCATION: Northern portion of parcel in front of building T.O.C.ELEV.: 100.00
DRILL MACHINE: CME 45B TRACK METHOD: HSA 0 HOUR DTW: 6.3 TOTAL DEPTH: 20.0
START DATE: 4/7/22 END DATE: 4/7/22 24 HOUR DTW: 5.4 WELL DEPTH: 20.0
DEPTH BLOW COUNT OVA LAB o a SOIL AND ROCK WELL
0.5ft 0.5ft 0.5ft 0.5ft (PPM) s G DEPTH DESCRIPTION ELEVATION DETAIL
0.0 LAND SURFACE 100.0 0.0
0.0 (FILL)-Silty FILL 0.0 — 0.5
6
3 6 NM D 1.0 99.0
s (ML)-Red and yellow,SILT
Tr.sand from 15-20'BLS and slight HCO
a
in
N
4.0
5.0 s.o
z
3 MW-01
10.0
2
4 5 NM M
a
oa
o�
L
N N
LL
— 15.0
6
— $ 8 N M Sat.
12
20.0 20.o so.o zo.o 20.0
BORING TERMINATED AT ELEVATION 80.0 ft in SILT
with tr.sand
EjPortland Cement EM Bentonite Pellets E1#2 Medium Sand
WELL CONSTRUCTION RECORD For Internal Use ONLY:
This form can be used for single or multiple wells
1.Well Contractor Information:
14.WATER ZONES
D.T. CHALMERS, JR. FROM I TO DESCRIPTION
Well Contractor Name ft ft
4146A ft ft
NC Well Contractor Certification Number IS.INNER CASING OR TUBING(geothermal closed-loo
FROM TO DIAMETER T1llCKNESS MATERIAL
CATLIN Engineers and Scientists 0 ft. 5 ft. 2 in.I Sch.40 1 PVC
Company Name 16.OUTER CASING for multi-cased wells OR LINER if applicable
FROM TO DIAMETER TIUCKNESS MATERIAL
2.Well Construction Permit#: NSA ft. �. ;n.
List all applicable well permits 6.e.County,State, Variance,Injection,etc)
ft. ft. in.
3.Well Use(check well use): 17.SCREEN
Water Supply Well: FROM TO DIAMETER SLOT SIZE TIRCKNESS MATERIAL
❑Agricultural ❑Municipal/Public 5 fr. 20 ft. 2 in. SIOt.010 Sch.40 PVC
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ff fr. in.
❑Industrial/Commercial ❑Residential Water Supply(shared) 18.GROUT
FROM TO MATERIAL EMPLACEMENT MET1IOD&AMOUNT
❑Irrigation 0 ft. 1 It. Portland Cement Surface Pour
Non-Water Supply Well:
®Monitoring ❑Recovery 1 ft. 2 It. Bent.Pellets Surface Pour
Injection Well: rt. rt.
❑Aquifer Recharge ❑Groundwater Rcmcdiation 19.SAND/GRAVEL PACK if a licable
❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO I MATERIAL EMPLACEMENTMETHOD
❑Aquifer Test ❑StonnwaterDrainage 2 f. 20;0 Medium Sand Torpedo Said
❑Experimental Technology ❑Subsidence Control ft ft.
20.DRILLING LOG attach additional sheets if necessar
❑Geothermal(Closed Loop) ❑Tracer FROM TO DESCRIPTION"color,hardness soil/rock rype,grainsizc,etc.
❑Geothermal(Heating/Cooling Return) ❑Other(explain under 421 Remarks) ft. ft.
4.Date Well(s)Completed: 04/07/22 Well ID#: MW-02 fr. fr.
ft. ft.
5a.Well Location:
ft ft.
NCDEQ-Annie Bowling Property NA
ft.
Facility/Owner Name Facility ID#(if applicable)
ft.
13109 N. ROXBORO ST., ROUGEMONT,NC 27572
ft. IT
Physical Address,City,and Zip
21.REMARKS
WAKE NA
County Parcel Identification No.(PIN)
5b.Latitude and Longitude in degrees/minutes/seconds or decimal degrees: 22.Certification:
(ifwell field,one lat/longis sufficient)
36.220187 N -78.927243 w C 4125/2022
Signature of Certified Well Contractor Date
6.Is(are)the well(s): ®Permanent or ❑Temporary By signing this form,I hereby certify that the welf(s)was(were)constructed in accordance with
15ANCAC 02C.0100 or 15ANCAC 02C.0200 Well Construction Standards and that a copy of
7.Is this a repair to an existing well: ❑Yes or ®No this record has been provided to the well owner.
If this is a repair,fill out known well construction information and explain the nature of
the repair under#21 remarks section or on the back of this form. 23.Site diagram or additional well details:
You may use the back of this page to pro-ride additional well site details or well
8.Number of wells constructed: 1 construction details. You may also attach additional pages ifnccessary.
For multiple injection or non-wader supply wells ONLYwith the same construction,you
can submit one form. SUBMITTAL INSTRUCTIONS
9.Total well depth below land surface: 20.0 (ft.) 24a.For All Wells: Submit this form within 30 days of completion of well
For multiple wells list all depths in different(example-3@200'and 2@7009 construction to the following:
10.Static water level below top of casing: 5.67 (ft,) Division of Water Resources,Information Processing Unit,
Ifwate-level is above casing use"+" 1617 Mail Service Center,Raleigh,NC 27699-1617
11.Borehole diameter: 8•25 (in.) 24b.For Injection Wells ONLY: In addition to sending the form to the
address in 24a above,also submit a copy of this form within 30 days of
12.Well construction method: HSA completion ofwell construction to the following:
(i.e.auger,rotary,cable,direct push,etc)
Division of Water Resources,Underground Injection Control Program,
FOR WATER SUPPLY WELLS ONLY: 1636 Mail Service Center,Raleigh,NC 27699-1636
13a.Yield(gpm) Method of test: 24c.For Water Svuuly&Injection Wells:
Also submit one copy of this form within 30 days of completion of well
13b.Disinfection type: Amount: construction to the county health department of the county where constructed.
Adapted from Form GW-1 North Carolina Department of Environment and Natural Resources-Division of Water Resources Revised 2-22-2016
CATLIN
WELL LOG Engineers and Scientists
zztoss SHEET 1 OF 1
PROJECT NO.: 221053 STATE: NC COUNTY: WAKE LOCATION: ROUGEMONT
PROJECT: ANNIE BOWLING PROPERTY LOGGED BY: OLIVIA DAYNES WELL ID:
DRILLER: D.T. CHALMERS, JR. MW-02
NORTHING: 2021463 EASTING: 899063 CREW: PATRICK MCCAIN
SYSTEM: NCSP NAD 83 USft BORING LOCATION: Southern portion of parcel in front of building T.O.C.ELEV.: 100.40
DRILL MACHINE: CME 45B TRACK METHOD: HSA 0 HOUR DTW: 5.5 TOTAL DEPTH: 20.0
START DATE: 4/7/22 END DATE: 4/7/22 24 HOUR DTW: 5.7 WELL DEPTH: 20.0
DEPTH BLOW COUNT OVA LAB o a SOIL AND ROCK WELL
0.5ft 0.5ft 0.5ft 0.5ft (PPM) s G DEPTH DESCRIPTION ELEVATION DETAIL
0.0 LAND SURFACE 100.4 0.0
(FILL)-Silty FILL 0.0 —
1.0 99.4 — 1.0
(ML)-Red to yellow SILT
Black streaks form 10-12'BLS > 2.0
Lt.brown from 15-20'BLS a
0
Un
N
5.0
of
oa
o�
U L
N N
LL
20.0 20.0 80.4 20.0 20.0
BORING TERMINATED AT ELEVATION 80.4 ft in SILT
EjPortland Cement EM Bentonite Pellets E1#2 Medium Sand
WELL CONSTRUCTION RECORD For InternalU, ONLY:
This form can be used for single or multiple wells
1.Well Contractor Information:
14.WATER ZONES
D.T. CHALMERS, JR. FROM I TO DESCRIPTION
Well Contractor Name ft ft
4146A ft ft
NC Well Contractor Certification Number 1S.INNER CASING OR TUBING(geothermal closed-loo
FROM TO DIAMETER THICKNESS MATERLll.
CATLIN Engineers and Scientists 0 ft. 5 ft. 2 irt.I Sch.40 1 PVC
Company Name 16.OUTER CASING for multi-cased wells OR LINER if applicable
FROM TO DIAMETER THICKNESS MATERIAL
2.Well Construction Permit#: NSA ft. ft. ;n.
List all applicable well permits(i.e.County,State, Variance,Injection,etc)
ft ft. in.
3.Well Use(check well use): 17.SCREEN
Water Supply Well: FROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL
❑Agricultural ❑Municipal/Public 5 fr. 20 ft. 2 in. SIOt.010 Sch.40 PVC
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) ft. fr. in.
❑Industrial/Commercial ❑Residential Water Supply(shared) 18.GROUT
FROM TO MATERIAL EMPLACEMENT MET1IOD&AMOUNT
❑Irrigation 0 ft. 0.5 It. Portland Cement Surface Pour
Non-Water Supply Well:
®Monitoring ❑Recovery 0.5 ft. 4 It. Bent.Pellets Surface Pour
Injection Well: rt. rt.
❑Aquifer Recharge ❑Groundwater Rcmcdiation 19.SAND/GRAVEL PACK if a licable
❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO I MATERIAL EMPLACEMENTMETHOD
❑Aquifer Test ❑StonnwaterDrainage 4 ft. 20;0 Medium Sand Torpedo Said
❑Experimental Technology ❑Subsidence Control ft. ft.
20.DRILLING LOG attach additional sheets if necessar
❑Geothermal(Closed Loop) ❑Tracer FROM TO DESCRIPTION color,hardness soil/rock rmc,grain size,etc.
❑Geothermnal(Heating/Cooling Return) ❑Other(explain under#21 Remarks) ft. ft.
4.Date Well(s)Completed: 04/08/22 Well ID#: MW-03 ft. ft. -
ft. ft.
5a.Well Location:
ft ft
NCDEQ-Annie Bowling Property NA
ft.
Facility/Owner Name Facility ID#(if applicable)
ft.
13109 N. ROXBORO ST., ROUGEMONT,NC 27572
ft. IT
Physical Address,City,and Zip
21.REMARKS
WAKE NA
County Parcel Identification No.(PIN)
5b.Latitude and Longitude in degrees/minutes/seconds or decimal degrees: 22.Certification:
(ifwell field,one lat/longis sufficient)
36.220135 N -78.927507 W C -� 4125/2022
Signature of Certified Well Contractor Date
6.Is(are)the well(s): ®Permanent or ❑Temporary By signing this form,I hereby certify that the well(s)was(were)constructed in accordance with
15ANCAC 02C.0100 or 15ANCAC 02C.0200 Well Construction Standards and that a copy of
7.Is this a repair to an existing well: ❑Yes or ®No this record has been provided to the well owner.
If this is a repair,fill out known well construction information and explain the nature of
the repair under#21 remarks section or on the back of this form. 23.Site diagram or additional well details:
You may use the back of this page to pro-ride additional well site details or well
8.Number of wells constructed: 1 construction details. You may also attach additional pages ifnecessary.
For multiple injection or non-water supply wells ONLYwith the same construction,you
can submit one form. SUBMITTAL INSTRUCTIONS
9.Total well depth below land surface: 20.0 (ft.) 24a.For All Wells: Submit this form within 30 days of completion of well
For multiple wells list all depths in different(example-3@200'and 2@1009 construction to the following:
10.Static water level below top of casing: 14.86 (ft.) Division of Water Resources,Information Processing Unit,
Ifwater level is above casing,use"+" 1617 Mail Service Center,Raleigh,NC 2 7 699-1 61 7
11.Borehole diameter: 8•25 (in.) 24b.For Injection Wells ONLY: In addition to sending the form to the
address in 24a above,also submit a copy of this form within 30 days of
12.Well construction method: HSA completion ofwell construction to the following:
(i.e.auger,rotanv,cable,directpush,etc.)
Division of Water Resources,Underground Injection Control Program,
FOR WATER SUPPLY WELLS ONLY: 1636 Mail Service Center,Raleigh,NC 27699-1636
13a.Yield(gpm) Method of test: 24c.For Water Svuuly&Injection Wells:
Also submit one copy of this form within 30 days of completion of well
13b.Disinfection type: Amount: construction to the comity health department of the county where constructed.
Adapted from Form GW-1 North Carolina Department of Environment and Natural Resources-Division of Water Resources Revised 2-22-2016
CATLIN
WELL LOG Engineers and Scientists
zztoss SHEET 1 OF 1
PROJECT NO.: 221053 STATE: NC COUNTY: WAKE LOCATION: ROUGEMONT
PROJECT: ANNIE BOWLING PROPERTY LOGGED BY: OLIVIA DAYNES WELL ID:
DRILLER: D.T. CHALMERS, JR. MW-03
NORTHING: 2021385 EASTING: 899044 CREW: PATRICK MCCAIN
SYSTEM: NCSP NAD 83 USft BORING LOCATION: Behind bulling in grassy area T.O.C.ELEV.: 101.65
DRILL MACHINE: CME 45B TRACK METHOD: HSA 0 HOUR DTW: 14.9 TOTAL DEPTH: 20.0
START DATE: 4/8/22 END DATE: 4/8/22 24 HOUR DTW: NM WELL DEPTH: 20.0
DEPTH BLOW COUNT OVA LAB o a SOIL AND ROCK WELL
0.5ft 0.5ft 0.5ft 0.5ft (ppm) s G DEPTH DESCRIPTION ELEVATION DETAIL
0.0 LAND SURFACE 101.7 0.0
(FILL)-Silty FILL 0'0 — 0.5
1.0 100.7
(ML)-Red and yellow,SILT
Orange from 10-12'BLS
Black streaks form 16-20'BLS a
Un
N
4.0
5.0
of
oa
o�
L
N N
LL
20.0 20.0 81.7 20.0 20.0
BORING TERMINATED AT ELEVATION 81.7 ft in SILT
EjPortland Cement 0Bentonite Pellets E1#2 Medium Sand
N N
s�
0
�0
0
�a
IP - l
M W-01
O
M W-02
& ® MW-03
LEGEND
® Monitoring Well
(Type II)
Approximate Location
LJ of Former UST Basin
Parcel Boundary
Source: Esri,Maxar, GeoE�re, Earthstar G�eogr phics, E /A bu DS,
USDA, USGS,AeroGRID, IGN,and the.GI- U er Comm ni
NOTE:Well and tank locations were obtained from previous
reports prepared by other consultants and are approximate. 30 15 0 30 60
Feet
PROJECT TITLE
FORMER ANNIE FIGURE
C1310ATLIN BOWLING PROPERTY SITE MAP
9 US HWY 501
Engineers and Scientists ROUGEMONT, NC
INCIDENT NO. I JOB NO. DATE SCALE DRAWN BY/CHECKED BY
17956 221053 APR 2022 AS SHOWN KMC/SJO