Loading...
HomeMy WebLinkAboutNC0026271_Compliance Evaluation Inspection_20220526ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS. JR. arrrctor Mr. David Odom, Town Manager Town of Taylorsville 344 Minnigan Lane Taylorsville, NC 28681 Dear Mr. Odom: NORTH 'CAROLINA Ern, irwimerrt f Quality May 26, 2022 Subject: Compliance Evaluation Inspection Taylorsville WWTP NPDES Permit No. NC0026271 Alexander County Enclosed is a copy of the Compliance Evaluation Inspection report for the inspection conducted at the subject facility on May 25, 2022, by Ori Tuvia and Michael Meilinger. The cooperation of Brian Eades during the site visit was much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of the enclosed report. Facility staff should investigate the reason that the above ground clarifier, which was recently cleaned, appeared to have a large amount of debris since the facility is equipped with both a bar screen and grit removal. It is recommended that the debris will be removed and the clarifier be observed in order to determine the source of the debris. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori.tuvia@ncdenr.gov. Cc: NPDES, MRO Files (Laserfiche) Sincerely, �DocuSigned by: Ai1.4ti H P-a. "-F161FB69A2D84A3... fo r W. Corey Basinger Regional Supervisor Mooresville Regional Office Division of Water Resources North Carolina Drpartrncnt of Environmental Quality I Division of War Resources MooresvillcktgionakOffice 1610East Center Avenue, Smote 301 I Mooresville, North.Carotlna 28115 704.663.16911 United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code 1 IN I 2 21IIIIII L NPDES yr/mo/day Inspection 3 I NC0026271 111 121 22/05/25 117 Type 18 i i IIIIIIIIIII Inspector Fac Type 19 I S I 201 IIIIIIIIIIIIIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 67I1.0 I 70I4 I 71IN I 72 I N I 731 I 74 751 I I 1 I I I I I I 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES Hermit Number) Taylorsville WWTP Minnigan Ln Taylorsville NC 28681 Entry Time/Date 09:30AM 22/05/25 Permit Effective Date 20/07/01 Exit Time/Date 12:OOPM 22/05/25 Permit Expiration Date 25/03/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Steve Brian Eades/ORC/828-632-5280/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted David Odom,67 Main Ave Dr Taylorsville NC 28681/Town Manager/828-632-2218/8286327964 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) Michael J Meilinger� Ori A Tuvia of Inspector(s) Agency/Office/Phone and Fax Numbers Date 5/26/2022 c—DocuSigned by: DWR/MRO WQ/704-235-2183/ �(- DWR/MRO WQ/704-663-1699/ `— BB057A2DE017498... Signature of ManiFrrggnist Andrew Pitney "A` viewer Agency/Office/Phone and Fax Numbers Date A H P4tIN5/26/2022 R/MRO WQ/704-663-1699 Ext.2180/ F161FB69A2D84A3... EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 NPDES yr/mo/day 31 NC0026271 111 121 22/05/25 I17 Inspection Type 18 [j 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# 2 Permit: NC0026271 Inspection Date: 05/25/2022 Owner - Facility: Taylorsville WWTP Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? • ❑ El El # Are there any special conditions for the permit? El • El El Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: The current permit expires on March 31, 2025 Record Keeping Are records kept and maintained as required by the permit? Is all required information readily available, complete and current? Are all records maintained for 3 years (lab. reg. required 5 years)? Are analytical results consistent with data reported on DMRs? Is the chain -of -custody complete? Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? Has the facility submitted its annual compliance report to users and DWQ? (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ▪ El El El Comment: The permittee's records were organized and well maintained, and records requested during the inspection were readily available. DMRs, COCs, calibration logs, ORC visitation logs and process control data were reviewed for the period December 2021 through April 2022. Page# 3 Permit: NC0026271 Inspection Date: 05/25/2022 Owner - Facility: Taylorsville WWTP Inspection Type: Compliance Evaluation Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ Comment: On -site analyses (pH and TRC) are performed under field laboratory certification #5062 (Town of Taylorsville). Water Tech Labs, Inc. (Certification #50) performs all remaining permit -required effluent analyses. The field instrumentation used on site appeared to be properly calibrated and documented; daily calibration/verification data is entered in the ORC log book. The field instrumentation is calibrated annually by Water Tech labs, Inc Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ Effluent Sampling Yes No NA NE Is composite sampling flow proportional? • ❑ ❑ ❑ Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? • ❑ ❑ ❑ Is the tubing clean? • ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 • El ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑ representative)? Comment: The effluent composite sampler was set for 200 mL and was collecting over 300 mL per aliquot when at the time of the inspection, the sampler should be calibrated. Operations & Maintenance Yes No NA NE Page# 4 Permit: NC0026271 Inspection Date: 05/25/2022 Owner - Facility: Taylorsville WWTP Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: At the time of the inspection the facility appeared to be properly operated and well maintained. The facility is equipped with a SCADA system and dissolved oxygen and pH PLC controllers are installed in the aeration basins for process control. Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? • ❑ ❑ ❑ Is the wet well free of excessive grease? • ❑ ❑ ❑ Are all pumps present? • ❑ ❑ ❑ Are all pumps operable? • ❑ ❑ ❑ Are float controls operable? ❑ ❑ ❑ • Is SCADA telemetry available and operational? • ❑ ❑ ❑ Is audible and visual alarm available and operational? ❑ ❑ ❑ • Comment: Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Grit Removal Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor? # Is disposal of grit in compliance? Yes No NA NE • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE Page# 5 Permit: NC0026271 Inspection Date: 05/25/2022 Owner - Facility: Taylorsville WWTP Inspection Type: Compliance Evaluation Grit Removal Yes No NA NE Comment: Flow Measurement - Influent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: The flow meter is calibrated/verified once per year. Yes No NA NE ❑ • ❑ ❑ • ❑ ❑ ❑ Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? • ❑ ❑ ❑ Are surface aerators and mixers operational? • El ❑ ❑ Are the diffusers operational? • ❑ ❑ ❑ Is the foam the proper color for the treatment process? • ❑ El El Does the foam cover less than 25% of the basin's surface? • El El El Is the DO level acceptable? • El ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/I) ■ El El El Comment: one of the two basins was out for maintenance at the time of the inspection Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • El El El Is the site free of excessive buildup of solids in center well of circular clarifier? • El El El Are weirs level? • El El El Is the site free of weir blockage? • ❑ ❑ ❑ Is the site free of evidence of short-circuiting? • ❑ ❑ ❑ Is scum removal adequate? El • ❑ ❑ Is the site free of excessive floating sludge? • El El El Is the drive unit operational? • ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? ■ ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? • El ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) • El El El Page# 6 Permit: NC0026271 Inspection Date: 05/25/2022 Owner - Facility: Taylorsville WWTP Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Comment: one of the two clarifiers was out for maintenance at the time of the inspection. at the time of the inspection the above ground clarifier, that was recently cleaned, appeared to have large amount of debris, facility staff should clear the floating debris and see if it comes back. Disinfection -Gas Yes No NA NE Are cylinders secured adequately? • ❑ ❑ ❑ Are cylinders protected from direct sunlight? • ❑ ❑ ❑ Is there adequate reserve supply of disinfectant? ■ ❑ ❑ ❑ Is the level of chlorine residual acceptable? • ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? • ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? • ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. ❑ • ❑ ❑ 7782-50-5)? If yes, then is there a Risk Management Plan on site? ❑ ❑ • ❑ If yes, then what is the EPA twelve digit ID Number? (1000- - ) If yes, then when was the RMP last updated? Comment: The chlorination and dechlorination systems are serviced by Piedmont Chlorinator Sales and Service, Inc De -chlorination Yes No NA NE Type of system ? Gas Is the feed ratio proportional to chlorine amount (1 to 1)? El El • ❑ Is storage appropriate for cylinders? • ❑ ❑ ❑ # Is de -chlorination substance stored away from chlorine containers? • ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ • ❑ Comment: Sulfer dioxide is used for disinfection Are tablet de -chlorinators operational? ❑ ❑ • ❑ Number of tubes in use? Comment: Aerobic Digester Yes No NA NE Is the capacity adequate? • ❑ ❑ ❑ Is the mixing adequate? ❑ ❑ ❑ • Is the site free of excessive foaming in the tank? • ❑ ❑ ❑ Page# 7 Permit: NC0026271 Inspection Date: 05/25/2022 Owner - Facility: Taylorsville WWTP Inspection Type: Compliance Evaluation Aerobic Digester # Is the odor acceptable? # Is tankage available for properly waste sludge? Comment: Residuals are land applied by Southern Soil under permit WQ0006906. Yes No NA NE • ❑ OE Chemical Feed Yes No NA NE Is containment adequate? • ❑ ❑ ❑ Is storage adequate? • ❑ ❑ ❑ Are backup pumps available? ❑ ❑ ❑ • Is the site free of excessive leaking? • ❑ ❑ ❑ Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: The flow meter is calibrated/verified once per year. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE El El El ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 8 Permit: NC0026271 Inspection Date: 05/25/2022 Owner - Facility: Taylorsville WWTP Inspection Type: Compliance Evaluation Standby Power Yes No NA NE Comment: The generator is auto cycled once per week and placed under load a few times per year. The generator is serviced annually and was last serviced by Carolina CAT Page# 9