Loading...
HomeMy WebLinkAboutNCG030293_Monitoring Report_20220408SHIELD ENCINEERING March 31, 2022 Ilk Alex Helms CIRCOR Pumps North America LLC �'oo�d� o� T 1710 Airport Road �s apti� c Monroe, North Carolina 28110 H Subject: Stormwater Sampling — March 2022 '� o Certificate of Coverage No. NCG030293 CIRCOR Pumping Technologies — Monroe, NC Shield Project No. 1150109-19 Dear Mr. Helms: Shield Engineering, Inc. (Shield) successfully collected a monthly stormwater sample for Stormwater Discharge Outfall (SDO) #004 at the CIRCOR Pumps North America LLC — Monroe facility on March 16, 2022. The pH was measured at 6.1 at SDO #004 and the total event precipitation was 0.34 inches. In addition to the collection of samples, Shield performed Qualitative Monitoring at SDO #004. Shield has prepared the Stormwater Discharge Monitoring Report (DMR) using the results of analyses from the commercial laboratory that the CIRCOR facility has contracted with, and the field values indicated above. The sampling results from the March 16`h event show that SDO #004 has met benchmark values for this sampling event. CIRCOR remains in Tier Three for Copper at SDO #004. Shield greatly appreciates the opportunity to provide environmental services to CIRCOR. If you have any questions in reference to this document or require further information, please feel free to contact the undersigned at (704) 394-6913. Respectfully, SHIELD ENGINEERING, INC. Magdaline Tzannis Senior Project Manager q.Greene Senior Engineer Attachments: DMR, QMR, Analytical Report — March 2022 Robert L. GriffmOPE President/CEO 4301 Taggart Creek Road www.shielden�ineeiing.com Telephone 704.394.6913 Charlotte, NC 28208 License No. F-0856 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0293 Person Collecting Samples: Magdalene Tzannis /Shield Engineering Inc. Facility Name: Circor Pumping Technologies Laboratory Name: Pace Analytical Facility County: Union Laboratory Cert. No.: 329 Discharge during this period: ✓ Yes No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes ✓ No If so, which Tier (I, ll, or III)? III A copy of this DM has b e uploaded electronically via httgs://eddcs.deg.nc.gbv/Forms/SW DMR [ Yes No Date Uploaded: Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall004 Outfall005 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date. Sample Collected MM/DD/YYYY 3/16/2022 46529 24-Hour Rainfall in inches 0.34 C0530 TSS in mg/L (100 or 50*) 12.4 pH in standard units (6.0-9.0 FW, 00400 6.8-8.5 SW) 6.1 Copper, total recoverable in mg/L 01119 0.010 FW, 0.0058 SW) 0.0080 Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) <0.010 Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) 0.036 Chemical Oxygen Demand (COD) in 00340 m /L (120) <20 00552 Non -Polar Oil & Grease in mg/L (15) <5.1 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): SDO #004 has met all benchmark values for this sampling event. SDO #005 is on quarterly sampling and was sampled in 2/22. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my Inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee or Delegated Authorized Individual 9 yJl 1;11X. coV k Email Address 7/ a Date 71) -6a/- 11F�-5� Phone Number SHIELD ENGINEERING March 31, 2022 Alex Helms CIRCOR Pumps North America LLC o 4; 0 1710 Airport Road ° G'o �y Monroe, North Carolina 28110IM Subject: Stormwater Sampling — March 2022 Certificate of Coverage No. NCG030293 CIRCOR Pumping Technologies — Monroe, NC Shield Project No. 1150109-19 Dear Mr. Helms: Shield Engineering, Inc. (Shield) successfully collected a monthly stormwater sample for Stormwater Discharge Outfall (SDO) #004 at the CIRCOR Pumps North America LLC — Monroe facility on March 16, 2022. The pH was measured at 6.1 at SDO #004 and the total event precipitation was 0.34 inches. In addition to the collection of samples, Shield performed Qualitative Monitoring at SDO #004. Shield has prepared the Stormwater Discharge Monitoring Report (DMR) using the results of analyses from the commercial laboratory that the CIRCOR facility has contracted with, and the field values indicated above. The sampling results from the March 161' event show that SDO #004 has met benchmark values for this sampling event. CIRCOR remains in Tier Three for Copper at SDO #004. Shield greatly appreciates the opportunity to provide environmental services to CIRCOR. If you have any questions in reference to this document or require further information, please feel free to contact the undersigned at (704) 394-6913. Respectfully, SHIELD ENGINEERING, INC. Magdaline Tzannis Senior Project Manager Melin Greene Senior Engineer Attachments: DMR, QMR, Analytical Report — March 2022 Robert L. Griffin, PE President/CEO 4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913 Charlotte, NC 28208 License No. F-0856 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0293 Person Collecting Samples: Magdaline Tzannis /Shield Engineering Inc. Facility Name: Circor Pumping Technologies Laboratory Name: Pace Analytical Facility County: Union Laboratory Cert. No.: 329 Discharge during this period: ✓ Yes 11 No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes ✓ No If so, which Tier (I, II, or III)? III uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR [Dyes No A copy of this DM has 7762Z„2;� Date Uploaded: Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall004 Outfall005 Outfall Outfall Outfall Code N/A Receiving Stream Class C C N/A Date Sample Collected MM/DD/YYYY 3/16/2022 46529 24-Hour Rainfall in inches 0.34 C0530 TSS in mg/L (100 or 50*) 12.4 pH in standard units (6.0-9.0 FW, 00400 6.8-8.5 SW) 6.1 01119 Copper, total recoverable in mg/L 0.0080 (0.010 FW, 0.0058 SW) 01051 Lead, total recoverable in mg/ L <0.010 9% o0 � r, (0.075 FW, 0.22 SW) Zinc, total recoverable in mg/ L (0.126 'cam 01094 FW, 0.095 SW) 0.036 Chemical Oxygen Demand (COD) in 00340 m /L (120) <20 00552 Non -Polar Oil & Grease in mg/L (15) <5.1 * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): SDO #004 has met all benchmark values for this sampling event. SDO #005 is on quarterly sampling and was sampled in 2/22. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." I Signature of Permittee or Delegated Authorized Individual S�e-p�ati. { �Iv��Y C9 .Gi'rc.ud'.CoV"\ Email Address Date Phone Number