Loading...
HomeMy WebLinkAboutNCG030166_Monitoring Report_202109275 Permit and Facility Information: nsa ,c Rease enter the perms nur ber and other details for lhs upload. m d IMPORTANT: Until the eDMR system is implemented for DEMLR Stormwater Program permits, an original sign¢ 0 hardcopy of the DMR MUST be mailed to the address in your permit, in addition to this electronic upload. * nrt Fields marked with a red asterisk are required. Permit Number* Enter 00Ccr Individual Femit Rirrber(NOT General Remit nuriter with all Us) NCG030166 Mst begn with KS a N G Facility Name:* Timken Company - Lincolnton Bearing Plant County:* Lincoln After uploading here, the original signed hardcopy must be mailed to: DEQ Mooresville Regional Office Attn: DEMLR Stormwater Program 610 East Center Avenue Suite 301 Mooresville, NC 28115 Further contact details at https:lldeq.nc.gov/contact/regional-offices/mooresville Monitoring Period Information: Monitoring Period `nhatsthe YEARof thesanpledate(s)? Year:* 2021 Multiple DMRs from sampling periods within the same year can be uploaded together, but please upload different years with a new submittal form. Also, copies of the lab results and qualitative (visual) monitoring should NOT be submitted unless specifically requested by DEQ staff Only upload the completed and signed DMR forms. DMR Upload* flick the upload button a drag and drop files here to attach docunent. Timken Lincolnton NCG030166 Stormwater DMR 36.52KB 3Q2021.pdf Only FCFS are accepted. Comments: This DMR submittal is for the 3rd Quarter 2021 rain stormwater sampling event * p By checking the box and signing box below, I certify that: • I have given true, accurate, and complete information on this form; • I agree that submission of this Data Monitoring Report (DMR) upload form is a "transaction" subject to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act'); • I agree to conduct this transaction by electronic means pursuant to Chapter 66, Article 40 of the NC General Statutes (the "Uniform Electronic Transactions Act"); • 1 understand that an electronic signature on this upload form has the same legal effect and can be enforced in the IZOVK/60 *:alep arvXgJv� *:ajnleu6lg b99Z-96L-bOL *:jagwnN auogd woo'ua�wlj uewpeq,Ruew *:ssaJPPV HM3 wul sq WoWns wsad p auq4 uewlleH'VLUeW *:aweNllnd wlo; peoldn iJINd slyl lwgns pue u61s Rpeolualoele of puslul l o 4NV :amleu6ls uaµ1.m a se Rev, ewes NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0166 Person Collecting Samples: Brice Fox Facility Name: Timken Co. Lincolnton Bearing Plant Laboratory Name: Pace Analytical Facility County: Lincoln Laboratory Cert. No.: 5342 Discharge during this period: v Yes No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes No If so, which Tier (I, II, or III)? A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR QYes No Date Uploaded: 09/14/2021 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall001 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class WS-IV N/A Date Sample Collected MM/DD/YYYY 08/1512021 46529 24-Hour Rainfall in inches 3/16" C0530 TSS in mg/L (100 or 50*) < 2.5mg/1 00400 PH in standard units (6.0 —9.0 FW, 6.2 6.8-8.5 SW) Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) < 0.005mg/l Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW) <0.005mg/I Zinc, total recoverable in mg/ L (0.126 01094 FW, 0.095 SW) < 0 010mg/I Chemical Oxygen Demand (COD) in 00340 mg/L (120) < 25.0mg/l 00552 Non -Polar Oil & Grease in mg/L (15) < 5.0mg/I * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 200 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including thepoysibilityof fines and imprisonment for knowing violations." 09/14/2021 Signature of PerAttee or Delegated Authorized Individual Date marty.haliman@timken.com Email Address 704-736-2854 Phone Number