Loading...
HomeMy WebLinkAboutNCG030085_Monitoring Report_20211228DAIMLER November 10, 2021 NCDEQ- Division of Water Resources 610 East Center Avenue Suite 301 Mooresville, North Carolina 28115 To whom it may concern: Sean Quarry Sr. Environmental Engineer Daimler Trucks 1800 North Main Street Mount Holly, NC 28120 704.822.7034 Phone RECEIVED/NCDEO/DWR DEC 2 S 2UZ1 WOROS MO©RESVILLE REGIONAL OFFICE Please find the enclosed November Stormwater Discharge Outfall (SDO) #001 and #002 form for the Daimler Trucks NA, LLC - Mount Holly Truck Manufacturing Plant (TMP). The stormwater samples were collected on November 4, 2021. Results from this sampling event show an exceedance of the following parameter(s) at or above the corresponding benchmark: • SDO #001 (11-04-2021) - COD - 220 mg/L (Benchmark 120 mg/L) • SDO #001 (11-04-2021) - Zinc - 0.230 mg/L (Benchmark 0.126 mg/L) Daimler remains in Tier 3 for Zinc and enters Tier 2 for C.O.D. at SDO #001. The Facility remains in Tier 3 for Zinc and Copper at SDO #002. Shield will continue to perform monthly sampling per Tier requirements until instructed to decrease sampling frequency by Daimler. Action Plans were accepted on October 26, 2021 and DTNA continues to make efforts to completion of these line items. Should you have any questions, please contact me at 704-822-7034 or sean.quarry@daimler.com. Sincerely, Daimler Trucks NA, LLC Sean Quarry Sr. Environmental Engineer Enclosures - DTNA signed DMR forms (2 copies) SHIELD ENGINEERING December 1, 2021 Mr. Sean Quarry Daimler Trucks North America, LLC 1800 North Main Street Mount Holly, NC 28120 Subject: Monthly Sampling — November 2021 NPDES General Permit No. NCGO30000 Daimler Trucks of North America LLC - Mount Holly, North Carolina Shield Project No.1140109-08 Dear Mr. Quarry: Shield Engineering, Inc. (Shield) successfully collected monthly stormwater samples for Stormwater Discharge Outfalls (SDO) #001 and #002 at the Mount Holly facility for the month of November 2021. During the November 4'h sampling event, Shield's field measurements of pH were 7.8 and 7.3, at SDO #001 and SDO #002, respectively. The analytical results of the stormwater samples collected during the qualifying storm event are attached to this cover letter. In addition, the Qualitative Monitoring Report (QMR) forms and the partially completed Discharge Monitoring Report (DMR) form are attached to this cover letter. The Qualitative Monitoring Reports note the presence of an intermittent sulfur -like odor at SDO ##001. Analytical results from the sampling event show an exceedance of C.O.D. and Zinc at SDO #001. The laboratory report notes that the TSS samples for both SDOs "were analyzed outside of analytical holding time for TSS due to laboratory error". Shield has contacted the laboratory and requested that your facility not be charged for these analyses. Daimler remains in Tier 3 for Zinc and enters Tier 2 for C.O.D. at SDO #001. The Facility remains in Tier 3 for Zinc and Copper at SDO # 002. Shield will continue to perform monthly sampling per Tier 3 requirements until instructed to decrease sampling frequency by Daimler. Shield greatly appreciates the opportunity to provide environmental services to Daimler Trucks, North America. If you have any questions in reference to this document or require further information, please feel free to contact either of the undersigned at (704) 394-6913. Respectfully, SHIELD ENGINEERING, INC. Magdaline Tzannis Senior Project Manager eli d M. Greene, EIT Senior Engineer Attachment: Discharge Monitoring Report — November 2021 I Robert L. Griffin, PE President/CEO 4301 Taggart Creek Road www.shieldeneineerina.com Telephone 704.394.6913 Charlotte, NC 28208 License No. F-0856 WCE1VED/NC0EO/DWR NCDEQ Division of Energy, Mineral and Land Resources , . r D'c� t S Z0�1 Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication WOROS Click here for instructions M60RESVILLE REGIONAL OFFICE Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMUR Regional Office. Certificate of Coverage No. NCG03 0085 Person Collecting Samples: Magdalene Tzennis Facility Name: Daimler Trucks - Mount Holly Laboratory Name: Pace Analytical Facility County: Gaston Laboratory Cert. No.: 329 Discharge during this period: + Yes No (fjno, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes No If so, which Tier (I, II, or III)? 11, III A copy of this DMR has bgen uploaded electronically via httas://edocs.deg.nc.gov/Forms/SW-DMR Ves No Date Uploaded: (�fic�I t- Analytical Monitoring Requirements for Outfalls with Industrial Activities -Benchmarks in (Red) Parameter Parameter Gutfall 001 Outfall 002 Outfall Outfall Outfall Code N/A Receiving Stream Class WS-IV; CA WS-IV; CA N/A Date Sample Collected MM/DD/YYYY 11/4/2021 11/4/2021 46529 24-Hour Rainfall in Inches 0.15 0.15 C0530 TSS in mg/L(100 or 50•) 26 26 pH in standard units (6.0-9.0 FW, D0400 6.8-8.5 SW) 7.8 7.3 Copper, total recoverable in mg/L 01119 (0.010 FW, 0.00S8 SW 0.004 0.0035 Lead, total recoverable in mg/ L 01051 (0.075 FW, 0.22 SW 0.00078 0.00054 Zinc, total recoverable in mg/ L (0.126 01094 F W, 0.095 SW) 0.230 0.082 Chemica(Oxygen Demand (COD) in 00340 mg/L(120 220 <20 00552 Non -Polar Oil & Grease in mg/L (15) 3.0 2.2 Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): COD and Zinc exceeded at SDO 001. Lab analyzed TSS samples from SDO 001 & SDO 002 outside of anatytical holding time. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision In accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge nd belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false infonnatiQ�ding thepossib�f fines and Imprisonment for knowing violations." Signature of Pt)rfnittee or Delegated Authorized Individual Grn . 2� �ds 4,t, N L✓u /� i. r� Email Address 70 V-d-z 2 -?o u v Phone Number SHIELD ENGINEERING December 1, 2021 Mr. Sean Quarry Daimler Trucks North America, LLC 1800 North Main Street Mount Holly, NC 28120 Subject: Monthly Sampling — November 2021 NPDES General Permit No. NCG030000 Daimler Trucks of North America LLC - Mount Holly, North Carolina Shield Project No.1140109-08 Dear Mr. Quarry: Shield Engineering, Inc. (Shield) successfully collected monthly stormwater samples for Stormwater Discharge Outfalls (SDO) #001 and #002 at the Mount Holly facility for the month of November 2021. During the November 4s' sampling event, Shield's field measurements of pH were 7.8 and 7.3, at SDO #001 and SDO #002, respectively. The analytical results of the stormwater samples collected during the qualifying storm event are attached to this cover letter. In addition, the Qualitative Monitoring Report (QMR) forms and the partially completed Discharge Monitoring Report (DMR) form are attached to this cover letter. The Qualitative Monitoring Reports note the presence of an intermittent sulfur -like odor at SDO #001. Analytical results from the sampling event show an exceedance of C.O.D. and Zinc at SDO #001. The laboratory report notes that the TSS samples for both SDOs "were analyzed outside of analytical holding time for TSS due to laboratory error". Shield has contacted the laboratory and requested that your facility not be charged for these analyses. Daimler remains in Tier 3 for Zinc and enters Tier 2 for C.O.D. at SDO #001. The Facility remains in Tier 3 for Zinc and Copper at SDO # 002. Shield will continue to perform monthly sampling per Tier 3 requirements until instructed to decrease sampling frequency by Daimler. Shield greatly appreciates the opportunity to provide environmental services to Daimler Trucks, North America. If you have any questions in reference to this document or require further information, please feel free to contact either of the undersigned at (704) 394-6913. Respectfully, SHIELD ENGINEERING, INC. Magdaline Taannis Senior Project Manager eli d M. Greene, EIT Senior Engineer Attachment: Discharge Monitoring Report — November 2021 4301 Taggart Creek Road Charlotte, NC 28208 �I Robert L. Griffin, PE President/CEO www.shieldenftineerina.com Telephone 704.394.6913 License No. F-0856 NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitorin¢ Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the aporopriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0085 Person Collecting Samples: Magdaline Tzannis Facility Name: Daimler Trucks - Mount Holly Laboratory Name: Pace Analytical Facility County: Gaston Laboratory Cert. No.: 329 Discharge during this period: + Yes No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? + Yes No If so, which Tier (I, 11, or III)? II, III A copy of this DMR has b en u loaded electronically via httos,//edocs deg nc gov/Forms/SW-DMR es No Date Uploaded: ('1� ( L Analytical Monitoring Requirements for Outfalls with Industrial Activities —Benchmarks in (Red) Parameter Parameter Outfall 001 Outfall 002 Outfall Outfall Outfall Code N/A Receiving Stream Class WS-IV; CA WS-IV; CA N/A Date Sample Collected MM/DD/YYYY 11/4/2021 11/4/2021 46529 24-Hour Rainfall in inches 0.15 0.15 C0530 TSS in mg/L(200 or 50') 26 26 00400 pH in standard units (6.0-9.0 FW, 7.8 7.3 6.8-8.5 SW) Copper, total recoverable in mg/L 01119 (0.010 FW, 0.0058 SW) 0.004 0.0035 Lead, total recoverable In mg/ L 01051 (0.075 FIN, 0.22 SW 0.00078 0.00054 Zinc, total recoverable in mg/ L(0.126 01094 FIN, 0.095 SW) 0.230 0.062 Chemical Oxygen Demand (COD) in 00340 mg/L(120 220 420 0055Z Non -Polar Oil & Grease in mg/L (15) 3.0 2.2 ' Outfalls to Outstanding Resource Waters (011i High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L All other water classifications have a benchmark of 100 mg/L FW (Freshwater) SW (Saltwater) Notes (optional): COD and Zinc exceeded at SOO 001. Lab analyzed TSS samples from SOO 001 & SDO 002 outside of analytical holding time. "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision In accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the Information submitted is, to best of my knowledge and belief, true, accurate, and complete. I am aware that there are signifcant penalties for submitting false inform ncluding the possib" of fines and imprisonment for knowing violations." /�/ Slenature of ermittee or Deleeated prized Individual Datel�JL—E-`--i— l_cl"7, rc CC,./?c,. g01q I, k,.,-., 7u-, 0Z7-7,),.a1 Email Address + Phone Number