HomeMy WebLinkAboutNCG030039_Monitoring Report_20211222DAIMLER
Colin Buchanan
Sr. Environmental Engineer
Daimler Trucks
P.O. Box 399
Cleveland, NC 27013
43 704.645.5353
December 2011, 2021
Division of Water Resources (DWR)
610 East Center Avenue
Suite 301
Mooresville, North Carolina 28115
To whom it may concern:
Please find enclosed stormwater sampling results for Stormwater Discharge Outfalls #001 and
#002 for the Cleveland facility in the month of November 2021. There was no qualifying event
for the month of November 2021.
Should you have any questions, please contact me at 704-645-5353 or
colin.buchanan@daimler.com.
Sincerely,
Daimler Trucks, LLC
Colin Buchanan
Sr. Environmental Engineer
Enclosures
SHIELD
ENGINEERING
December 2, 2021
Mr. Colin Buchanan
Daimler Trucks of North America, LLC
11550 Statesville Boulevard
Cleveland, NC 27013
G^
Subject: Monthly Sampling — November 2021
NPDES General Permit No. NCG030000/CoC No. NCG030039
Daimler Trucks of North America, LLC
11550 Statesville Boulevard, Cleveland, North Carolina
Shield Project No. 1140111-09
Dear Mr. Buchanan:
There were no qualifying rainfall events for the month of November 2021 as defined by General Permit
No. NCG030000. As a result, no monthly stormwater samples were collected for Stormwater Discharge
Outfalls (SDO) #001 and SDO #002 at the Daimler Trucks — Cleveland Facility in November. According
to rainfall data' collected for the month, three rain events or group events occurred on November 4',
November 111 , and November 22nd, producing 0.05 inches, 0.23 inches, and 0.11 inches of rain,
respectively. However, each of these events took place after normal business hours, within 72 hours of the
last rain event, or did not produce enough rainfall to collect a sample. Shield will continue to monitor daily
weather conditions and attempt coordination of appropriate staff and resources to facilitate adequate sample
collection. A partially completed Discharge Monitoring Report form is attached to this cover letter for
signature of the appropriate authorized permittee and submittal to the State.
Daimler's Cleveland facility has exited Tier Three at SDO #001 for Copper and will be monitored on a
quarterly basis. The facility remains in Tier Three of the NPDES General Permit No. NCG030000 at SDO
#002 for Copper and Zinc. Shield greatly appreciates the opportunity to provide environmental services to
Daimler Trucks of North America. if you have any questions in reference to this document or require further
information, please feel free to contact undersigned at (704) 394-6913.
Respectfully,
SHIE D ENGINEERING, INC.
Magdalene zannes
Senior Project Manager
Mel da
Seni E gineer
Attachment: Discharge Monitoring Report — November 2021
1 Rainfall data collected from onsite rain gauge by DTNA-Cleveland.
obert L. Griffin,
President/CEO
4301 Taggart Creek Road www.shieldengineering.com Telephone 704.394.6913
Charlotte, NC 28208 License No. F-0856
1;�
NCDEQ Division of Energy, Mineral and Land Resources
Stormwater Discharge Monitoring Report (DMR) Form for NCG030000
Metal Fabrication
Click here for instructions
Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DI1i(R`f?iYload%rm within
30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the aouroariate DWLR Regional Office.
Certificate of Coverage No. NCG03 0039
Person Collecting Samples: NA
Facility Name: Daimler Trucks - Cleveland, NC
Laboratory Name: NA
Facility County: Rowan
Laboratory Cert. No.: NA
Discharge during this period:
LjYes
+
No (if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions this sample Period for any benchmark exceedances7 D Yes + No
If so, which Tier (I, 11, or III)?
A copy of this DMR has been uploaded electronically via https•//edocs deg.nc.goy/Forms/SW-DMR Dyes DNo
Date Uploaded: i2 zv 2ns 1
Analvtiral Monitoring Reouirements for Outfalls with Industrial Activities — Benchmarks in (Red)
Parameter
Parameter
Outfall001
Outfall002
Outfall
Outfall
Outfall
Code
N/A
Receiving Stream Class
C
C
N/A
Date Sample Collected MM/DD/YYYY
NOE
NOE
46529
24-Hour Rainfall in inches
C0530
TSS in mg/L (100 or 50•)
pH in standard units (6.0-9.0 FW,
00400
6.8-8.5 SW)
Copper, total recoverable in mg/L
01119
(0.010 FW, 0.0059 SW)
Lead, total recoverable in mg/ L
01051
(0.075 FIN, 0.22 SW)
Zinc, total recoverable in mg/ L(0.126
01094
FW, 0.095 SW)
Chemical Oxygen Demand (COD) in
00340
mg/L(120)
00552
Non -Polar Oil & Grease in mg/L(15)
` Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas IrNAI
have a benchmark TS5 limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L
FW (Freshwater) SW (Saltwater)
Notes (optional): NOE during this period.
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in
accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my
Inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information
submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting
false information, including the possibility of fines and imprisonment for knowing violations."
or Delegated Authorized Individual
Email Address
/ Z/70�702
Date
:�y4 - bv5- Sr oe
Phone Number