Loading...
HomeMy WebLinkAboutNCG030004_Monitoirng Report_20210930RECEIVED NCDEQDivision ofEnergy, Mineral and Land Resources SFp 3 o 7071 Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMRI Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG030004 Person Collecting Samples: Michael Kilpatrick Facility Name: Duff -Norton Laboratory Name: Pace Analytical Facility County: Mecklenburg Laboratory Cert. No.:329 Discharge during this period: O Yes No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? Yes No If so, which Tier (I, II, or III)? A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR QYes No Date Uploaded:09/15/2021 Analytical Monitoring Requirements for Outfalls with Industrial Activities— Benchmarks in (Red) Parameter Parameter Outfall 002 Outfall 003 Outfall 004 Outfall Outfall Code N/A Receiving Stream Class C C C N/A Date Sample Collected MM/DD/YYYY 08/16/2021 08/16/2021 08/16/2021 46529 24-Hour Rainfall in inches 0.2 0.2 0.2 C0530 TSSin mg/L(100or5o*) <2.5 mg/L <2.5 mg/L <2.5 mg/L 00400 pH in standard units (6.0-9.0 FW, 6.3 6.5 6.8 6.8-8.5 SW) 01119 Copper, total recoverable in mg/L <0 010 mg/L <0.010 mg/L <0.010 mg/L (0.010 FW, 0.0058 SW) 01051 Lead, total recoverable in mg/ L <0.010 mg/L <0.010 mglL <0.010 mg/L (0.075 FW, 0.22 SW) 01094 Zinc, total recoverable in mg/ L (0.126 <0.020 mg/L <0.020 mglL <0.020 mg/L FW, 0.095 SW) 1 00340 Chemical Oxygen Demand (COD) in <20 mg/L <20 mg/L <20 mg/L mg/L(120) 00552 Non -Polar Oil & Grease in mg/L (15) <5.0 mg/L <5.0 mg/L 15.1 mg/L * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary NurseryAreas (PNA) have a benchmark T55 limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L FW (Freshwater)SW (Saltwater) Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee o�D�Iegated Authorized john.mulvey@cmworks.com U Email Address 09/15/2021 Date 704-609-2214 Phone Number