Loading...
HomeMy WebLinkAboutNC0079057_Inspection_20220607ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director Josh O'Brien Town of Manteo PO Box 246 Manteo, NC 27954-0246 NORTH CAROLINA Environmental Quality June 07, 2022 SUBJECT: Toxicity Compliance Inspection Report Manteo WWTP NPDES WW Permit No. NC0079057 Dare County Dear Mr. O'Brien: The North Carolina Division of Water Resources conducted a Toxicity Compliance inspection of the Manteo WWTP on 5/24/2022. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0079057. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". If you should have any questions, please do not hesitate to contact me with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481 or via email at robert.e.bullock@ncdenr.gov. Cc: Laserfiche Sincerely, Robbie Bullock, Environmental Program Consultant Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ North Carolina Department of ErvIronmental Quality I Dlvlslon of Waler Resources Washington Regional Office 1 943 Washington Square Mall I Washington, North Carolina 27889 252.946.6481 United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 IN I 2 IL I 3 I NC0079057 111 121 22/05/24 117 Type 181 R I IIIIIIIIIII Inspector Fac Type 191 S I 201 . I 21IIIIII IIIIIIIIIIIIIIIIII I IIIIII P6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 I 7° I3 I 711D 1 72 I N I 73I I 74 71 I I 1 I I I I I I 180 l Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Manteo WWTP 710 Bowsertown Rd Manteo NC 27954 Entry Time/Date 10:OOAM 22/05/24 Permit Effective Date 19/07/01 Exit Time/Date 11:30AM 22/05/24 Permit Expiration Date 23/12/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Joshua J O'Brien/ORC/252-473-3513/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Nathan Pharr,PO Box 246 Manteo NC 279540246//252-305-3491/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenar Records/Reports Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Robert E Bullock DWR/WARO WQ/252-948-3843/ 6/7/2022 ,e6,A aueee, Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 31 NPDES yr/mo/day N C0079057 I11 121 22/05/24 17 Inspection Type 18 LB] 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The review period for this inspection was October 2020 through March 2022. No Notices were issued over the review period. March 2022 DMR was spot checked for accuracy with no discrepancies found. An Acute 24-hour Pimephales promelas pass -fail toxicity test was taken during the inspection. The result of this test was Pass. The facility is judged to be Compliant with the Toxicity Compliance Inspection. Page# 2 Permit: NC0079057 Inspection Date: 05/24/2022 Owner - Facility: Manteo WWTP Inspection Type: Bioassay Compliance Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ME application? Is the facility as described in the permit? • ❑ El El # Are there any special conditions for the permit? • ❑ ❑ ❑ Is access to the plant site restricted to the general public? • ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑ Comment: The current permit is effective until December 31, 2023. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable MEI ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The facility appeared to be well maintained and operated. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • ❑ ❑ ❑ Is all required information readily available, complete and current? • ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? • El El El Are analytical results consistent with data reported on DMRs? • El El El Is the chain -of -custody complete? • ❑ El El Dates, times and location of sampling El Name of individual performing the sampling El Results of analysis and calibration ❑ Dates of analysis El Name of person performing analyses El Transported COCs El Are DMRs complete: do they include all permit parameters? • El El El Has the facility submitted its annual compliance report to users and DWQ? • ❑ El El (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified El El • El operator on each shift? Is the ORC visitation log available and current? • El El El Is the ORC certified at grade equal to or higher than the facility classification? • El El El Is the backup operator certified at one grade less or greater than the facility • El El El classification? Page# 3 Permit: NC0079057 Inspection Date: 05/24/2022 Owner - Facility: Manteo WWTP Inspection Type: Bioassay Compliance Record Keeping Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Josh O'Brien is the ORC with Edward Hanusik as the Backup ORC. Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: On the day of inspection the mechanical bar screen was in operation. Screenings are disposed of in the landfill Grit Removal Type of grit removal a.Manual b.Mechanical Is the grit free of excessive organic matter? Is the grit free of excessive odor? # Is disposal of grit in compliance? Comment: Grit is disposed of in the landfill Influent Sampling # Is composite sampling flow proportional? Is sample collected above side streams? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is sampling performed according to the permit? Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ❑ • ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 4 Permit: NC0079057 Inspection Date: 05/24/2022 Owner - Facility: Manteo WWTP Inspection Type: Bioassay Compliance Influent Sampling Comment: Sampler is on constant time and constant volume. The sampler temperature was 5 degrees on the day of inspection Yes No NA NE Oxidation Ditches Yes No NA NE Are the aerators operational? • ❑ ❑ ❑ Are the aerators free of excessive solids build up? • ❑ ❑ ❑ # Is the foam the proper color for the treatment process? • ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? • ❑ ❑ ❑ Is the DO level acceptable? • ❑ ❑ ❑ Are settleometer results acceptable (> 30 minutes)? ❑ ❑ ❑ • Is the DO level acceptable?(1.0 to 3.0 mg/I) • ❑ ❑ ❑ Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) ❑ ❑ El • Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ■ ❑ ❑ ❑ Are weirs level? • ❑ El ❑ Is the site free of weir blockage? • El El El Is the site free of evidence of short-circuiting? • ❑ ❑ ❑ Is scum removal adequate? • El El El Is the site free of excessive floating sludge? • El El ❑ Is the drive unit operational? • El El El Is the return rate acceptable (low turbulence)? • ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? ■ El El El Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) El El El • Comment: Aerobic Digester Is the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? Yes No NA NE ▪ El El El • ❑ ❑ ❑ Page# 5 Permit: NC0079057 Inspection Date: 05/24/2022 Owner - Facility: Manteo WWTP Inspection Type: Bioassay Compliance Aerobic Digester # Is tankage available for properly waste sludge? Comment: On the day of inspection the air was off to allow the sludge to settle Yes No NA NE • ❑ ❑ ❑ Filtration (High Rate Tertiary) Yes No NA NE Type of operation: Down flow Is the filter media present? • ❑ El El Is the filter surface free of clogging? ■ El El El Is the filter free of growth? • ❑ ❑ ❑ Is the air scour operational? ❑ ❑ ❑ • Is the scouring acceptable? ❑ ❑ El • Is the clear well free of excessive solids and filter media? ■ ❑ ❑ ❑ Comment: Disinfection -Liquid Is there adequate reserve supply of disinfectant? (Sodium Hypochlorite) Is pump feed system operational? Is bulk storage tank containment area adequate? (free of leaks/open drains) Is the level of chlorine residual acceptable? Is the contact chamber free of growth, or sludge buildup? Is there chlorine residual prior to de -chlorination? Comment: Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ De -chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount (1 to 1)? • ❑ ❑ ❑ Is storage appropriate for cylinders? ❑ ❑ • ❑ # Is de -chlorination substance stored away from chlorine containers? • ❑ ❑ ❑ Are the tablets the proper size and type? El El • El Comment: Sodium Bisulfite is used for dechlor Are tablet de -chlorinators operational? El El • El Number of tubes in use? Comment: Page# 6 Permit: NC0079057 Inspection Date: 05/24/2022 Owner - Facility: Manteo WWTP Inspection Type: Bioassay Compliance Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: The effluent flow meter was calibrated on October 8, 2021 by Delta Systems Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ • ❑ ❑ Is sample collected below all treatment units? • ❑ ❑ ❑ Is proper volume collected? • ❑ ❑ ❑ Is the tubing clean? • ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 • ❑ ❑ ❑ degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type • ❑ ❑ ❑ representative)? Comment: The effluent sampler is on constant time and constant volume. A 600 ml sample is taken every hour over 24 hours. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: No adverse conditions were visible from the shore on the day of inspection Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Page# 7