Loading...
HomeMy WebLinkAboutNCG060422_Tier Two Response Report to MRO_20220221Georgoulias, Bethany From: Dina Kolker <Dina.Kolker@bsigroup.com> Sent: Friday, June 3, 2022 11:42 AM To: Khan, Zahid Cc: Lee Fankhauser; Ashley Taylor; EMILY AFFLITTO; Sarah Zagurski; jmsmills@amazon.com; Stevens, James; Georgoulias, Bethany; Carson, Brittany Subject: [External] Amazon.com Services LLC — CTL6 Tier Two Stormwater Monitoring Two Consecutive Benchmark Exceedances Attachments: 1019340 Amazon CLT6 SW Q2 Tier Two Response 060222.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Dear Zahid, Please see the attached Tier Two response report prepared for Amazon.com Services LLC — CTL6 facility due to two consecutive exceedances. The facility submitted the report due to two consecutive pH exceedances in accordance with Table 4, Section E-6 of North Carolina's General Permit NCG060000. Please do not hesitate to contact me should you have questions or require additional information regarding the above - outlined Benchmark Value exceedance or Tier One Response/Action plan. Thank you, Dina Kolker EHS Associate Consultant T:646-578-0204 Dina. KolkerObsigroup.com bs't* * Inspiring trust for a more resilient world. BSI EHS Services and Solutions, 1187 Main Avenue, Suite 213, Clifton, NJ 07011 bsigroup.com/ehs I LinkedIn We support the UN Sustainable Development Goals, so please consider the environment before printing this email LEGAL NOTICE: Unless expressly stated otherwise, this message is confidential and may be privileged. It is intended for the addressee(s) only. Access to this E-mail by anyone else is unauthorized. If you are not an addressee, any disclosure or copying the contents of this E-mail or any action taken (or not taken) in on it is unauthorized and may be unlawful. If you are not an addressee, please inform the sender immediately. Please consider the environment before printing this emaill Visit the BSI website at www.bsi2rouo.com This email may contain confidential information and/or copyright material. This email is intended for the use of the addressee only. Any unauthorised use may be unlawful. If you receive this email by mistake, please advise the sender immediately by using the reply facility in your email software. The British Standards Institution is incorporated by Royal Charter. This email has been scanned for all known viruses. bs'1*0' June 2, 2022 North Carolina Department of Environmental Quality Morresville Regional Office 610 East Center Avenue, Suite 301 Morrisville, North Carolina 28115 In Transmitted via Electronic Mail Zahid.khan@ncdenr.gov Re: Tier Two Stormwater Monitoring Two Consecutive Benchmark Exceedances Amazon.com Services LLC — CTL6 12220 Carolina Logistics Drive Pineville, North Carolina 281 134 Certificate of Coverage #: NCG060422 Dear Sir or Madam: BSI Consulting (BSI) performed a stormwater monitoring event on May 23, 2022 at the Amazon.com Services LLC — CTL6 facility located at 12220 Carolina Logistics Drive in Pineville, North Carolina (the facility) in accordance with their approved Certificate of Coverage #:NCG060422. Per the facility's Stormwater Pollution Prevention Plan (SWPPP), stormwater samples were collected from two locations (Sampling Point 01 and Sampling Point 02) and analyzed for total suspended solids (TSS), chemical oxygen demand (COD), and pH. North Carolina's Benchmark Values for these analytes are 100 milligrams per liter (mg/L), 120 mg/L, and 6.0 — 9.0 standard units (S.U.), respectively. The sample locations and designations are shown within the Drainage Area Site Map for the facility that has been included as an attachment to this response letter. While the results of the TSS and COD analyses for the sampling points did not result in a Benchmark Value exceedance, pH was reported above North Carolina's Benchmark Value of 9.0 S.U. at each of the two sampling points. The pH value for Sample Point 01 was 9.39 S.U. and the pH value for Sample Point 02 was 10.09 S.U. BSI Project No. 1019340 Amazon CLT6 SW Q2 Tier Two Response 060222 North Carolina Department of Environmental Quality, Morresville Regional Office Page 2 Photos Sample Point 01 Field pH Sample Point 02 Field pH The facility has implemented the following responses as a result of the pH exceedances in accordance with Table 4, Section E-6 of North Carolina's General Permit NCG060000: • The exceedance and sampling date will be recorded within the facility's SWPPP. • The North Carolina Department of Environmental Quality, Division of Energy, Mineral, and Land Resource's Regional Office will receive the transmission of this letter (via email), a copy of which will be recorded within the facility's SWPPP. • An inspection of the site was completed on May 23, 2022 to, in part, identify any potential sources of stormwater impacts from the facility. • The site inspection did not identify an obvious source of the elevated pH recorded at the site. There is no record of the use of materials or spills that could increase the pH of the stormwater. • In the previous inspection completed on February 4, 2022, elevated pH was recorded and triggered a Tier One Response. The selected action plan outlined in the Tier 1 Response was implemented and there was no salt for de-icing purposes on the site during the May 23, 2022 inspection. Please do not hesitate to contact me should you have questions or require additional information regarding the above outlined Benchmark Value exceedance or Tier Two Response/Action plan. Regards, Reviewed by: Dina 9foffieA Ree JanPhmme�t Dina Kolker Lee Fankhauser EHS Associate Consultant Senior Consultant Dina.Kolker@bsigroup.com T: 646.578.0204 Attachments Attachment 1: Drainage Area Site Map BSI Project No. 1019340 Amazon CLT6 SW Q2 Tier Two Response 060222 North Carolina Department of Environmental Quality, Morresville Regional Office Attachment I Attachment I Drainage Area Site Map BSI Project No. 1019340 Amazon CLT6 SW Q2 Tier Two Response 060222 ay awai cnane ro Employee rri ' -� Parking Area Drainage Area1 • f/ I IL 4' Hydrogen Fuel Station Aw Employee p Parking Area �` �• 7 + �. b Fee 7 Feet so,�,« wcs ,saa w.n M.r�mr a�.amr�son.r. ...... 7,01 -oil loll i-,•! A ' - .� � /+arrrwn Sa1,sb�rYi+G Rrt MooresWlle - SheIM �Fv�n� ananbu.q 1 - 1 Scrubber - Dump ! —`�•••iq,' Legend ■ � ® Outfall ❑ Stormwater Drain �^ i "•► Yard Inlet � Stormwater Inlet Employee A Hydrogen AST Parking Area 0 Generator (Diesel) Transformer Trash Compactor r # Sampling Point Manhole Stormwater Outlet Stormwater Underground Piping Sampling Surface Water Flow Direction Point01 / Mobile Washing Area Mobile Maintenance Area Mobile Fueling Area Q Fire Pump Room (Diesel) Q Drainage Area i ® Detention Basin Building ® Impervious Area j / ■ 6W Amazon Leased Boundary j k mpling „1int 02 Ste,■ Site Boundary �- Notes: _ 1. Amazon Leased Boundary is 54.15 Acres Imo. �/ •�� • Employee 2. Impervious Area is 41.74 Acres Lg /Fi ure 2 4 Parking Area Drainage Area Site Map r ��'�.`�,.,• i' Site CLT6 12220 Carolina Logistics Drive Outfall 001 Pineville, North Carolina 28134 �„i .: �� ,r•a� Mecklenburg County •1�' Environmental AesourceµWWnageme�nt