Loading...
HomeMy WebLinkAboutNC0020338_Modification_20220603DocuSign Envelope ID: 0FF5975E-476C-422F-AF33-9F7010C269DE Permit NC0020338 Part I A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS (2.5 MGD) [15A NCAC 02B .0400 et seq., 02B .0500 et seq.] Grade III Biological Water Pollution Control System [15A NCAC 08G .0302] During the period beginning on the effective date of this permit and lasting until expiration, the Permittee is authorized to discharge up to 2.5 MGD treated wastewater through Outfall 001. Such discharges shall be limited and monitored' by the Permittee as specified below: Effluent Characteristics Parameter Code Discharge Limitations Monitoring Requirements Monthly Average Weekly Average Daily Maximum Measurement Frequency Sample Type Sample Location 2 Flow 50050 2.5 MGD Continuous Recording I or E BOD5 (20°C) 3 [Summer] C0310 16.0 mg/L 24.0 mg/L 3/Week Composite I, E BOD5 (20°C) 3 [Winter] C0310 30.0 mg/L 45.0 mg/L 3/Week Composite I, E Total Suspended Solids 3 C0530 30.0 mg/L 45.0 mg/L 3/Week Composite I, E NH3 as N [Summer] C0610 2.0 mg/L 6.0 mg/L 3/Week Composite E NH3 as N [Winter] C0610 4.0 mg/L 12.0 mg/L 3/Week Composite E Dissolved Oxygen 00300 Daily Average not less than 5.0 mg/L 3/Week Grab E, U, D pH 00400 Between 6.0 and 9.0 standard units 3/Week Grab E Total Residual Chlorine 4 50060 28 µg/L 3/Week Grab E Temperature (°C) 00010 Monitor and Report Daily Grab E Temperature (°C) 00010 Monitor and Report 3/Week Grab U, D Fecal Coliform 31616 (geometric mean) 200/100m1 400/100m1 3/Week Grab E, U, D Oil and Grease 00556 Monitor and Report Quarterly Grab E Conductivity (µmhos/cm) 00094 Monitor and Report 3/Week Grab E, U, D Total Nitrogen 5 (mg/L) C0600 Monitor and Report Weekly Composite E Total Phosphorus (mg/L) C0665 Monitor and Report Weekly Composite E Total Copper 6 01042 34.5 ug/L 46.6 ug/L Monthly Composite E Total Silver (ug/L) 01077 Monitor and Report Quarterly Composite E Total Zinc (ug/L) 01092 Monitor and Report Quarterly Composite E Tot Hardness [as CaCO3] 00900 Monitor and Report Quarterly Composite E Total Hardness [as CaCO3] 00900 (mg/L) Monitor and Report Quarterly Grab U 8 Chronic Toxicity 9 TGP3B Monitor and Report Quarterly Composite E Effluent Pollutant Scan NC01 Monitor and report Footnote 10 E Footnotes: 1. The permittee shall submit discharge monitoring reports electronically using the NC DWR's eDMR application system [see A. (6)] . 2. Sample locations: I — Influent; E — Effluent; U — Upstream at the Old US-421 crossing; D — Downstream at the NCSR 1510 crossing and at the NCSR 1146 crossing. Upstream and downstream samples shall be grab samples collected 3/Week during the months of June, July, August, and Sep &I;yonce per week during Page 3 of 11 kattd, Ik b C464531431644FE for Richard E. Rogers. Jr, Director Date: June 3, 2022 DocuSign Envelope ID: 0FF5975E-476C-422F-AF33-9F7010C269DE Permit NC0020338 the other months of the year. As a participant in the Yadkin -Pee Dee River Basin Association, the instream monitoring requirements for dissolved oxygen, temperature, fecal coliform and conductivity are waived. Should your membership in the association be terminated, you shall notify the Division and begin instream sampling immediately. 3. The monthly average effluent BOD5 and Total Suspended Solids concentrations shall not exceed 15% of the respective influent value (85% removal). 4. Monitoring only if effluent is chlorinated. The Division shall consider all effluent TRC values reported below 50 µg/L to be in compliance with the permit. However, the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified), even if these values fall below 50 lag/L. 5. TN = TKN + NO3-N + NO2-N where TN is Total Nitrogen, TKN is Total Kjeldahl Nitrogen, and NO3-N + NO2-N are Nitrate and Nitrite Nitrogen, respectively. 6. A 5-year schedule of compliance has been added to the permit [See A. (5) Schedule of Compliance for total copper]. 7. Effluent Total Hardness sampling shall be conducted in conjunction with effluent metals for the pretreatment program (Cadmium, copper, lead, nickel, silver, and zinc). 8. The permittee shall sample instream hardness upstream of the facility's discharge. The sample shall be representative of the hardness in the receiving stream. If the permittee is a member of a monitoring coalition program, sampling for instream hardness may be waived as long as the monitoring coalition agrees to sample hardness at the nearest upstream location, at a minimum frequency of quarterly, and the permittee has obtained approval from DWR-NPDES Permitting Unit that the upstream station being monitored by the Coalition is representative of the receiving stream for this discharge. The permittee is responsible for submitting instream hardness test results with its permit renewal application package. If Coalition membership is cancelled or the Coalition terminates instream hardness sampling at the approved station, the permittee will immediately notify the Division and resume sampling for instream hardness upstream of its discharge. 9. Chronic Toxicity (Ceriodaphnia) limit at 50% with testing in January, April, July and October [see A. (2)]. 10. The permittee shall perform three effluent pollutant scans during the term of this permit [See A. (3)]. [Summer] = April 1- October 31 [Winter] = November 1- March 31 There shall be no discharge of floating solids or visible foam in other than trace amounts. Page 4 of 11 �DocuSigned by: !Wawa kbtAkledih `—f.4645'114'111i44FF for Richard E. Rogers. Jr, Director Date: June 3, 2022 DocuSign Envelope ID: 0FF5975E-476C-422F-AF33-9F7010C269DE Permit NC0020338 submit DMRs electronically using the internet. The eDMR system may be accessed at: https://deq.nc.gov/about/divisions/water-resources/edmr. NC DEQ / Division of Water Resources / Water Quality Permitting Section ATTENTION: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 If a permittee is unable to use the eDMR system due to a demonstrated hardship or due to the facility being physically located in an area where less than 10 percent of the households have broadband access, then a temporary waiver from the NPDES electronic reporting requirements may be granted and discharge monitoring data may be submitted on paper DMR forms (MR 1, 1.1, 2, 3) or alternative forms approved by the Director. Duplicate signed copies shall be submitted to the mailing address above. See "How to Request a Waiver from Electronic Reporting" section below. Regardless of the submission method, the first DMR is due on the last day of the month following the issuance of the permit or in the case of a new facility, on the last day of the month following the commencement of discharge. Starting on December 21, 2025, the permittee must electronically report the following compliance monitoring data and reports, when applicable: • Sewer Overflow/Bypass Event Reports; • Pretreatment Program Annual Reports; and • Clean Water Act (CWA) Section 316(b) Annual Reports. The permittee may seek an electronic reporting waiver from the Division (see "How to Request a Waiver from Electronic Reporting" section below). 2. Electronic Submissions In accordance with 40 CFR 122.41(1)(9), the permittee must identify the initial recipient at the time of each electronic submission. The permittee should use the EPA's website resources to identify the initial recipient for the electronic submission. Initial recipient of electronic NPDES information from NPDES-regulated facilities means the entity (EPA or the state authorized by EPA to implement the NPDES program) that is the designated entity for receiving electronic NPDES data [see 40 CFR 127.2(b)]. EPA plans to establish a website that will also link to the appropriate electronic reporting tool for each type of electronic submission and for each state. Instructions on how to access and use the appropriate electronic reporting tool will be available as well. Information on EPA's NPDES Electronic Reporting Rule is found at: http s://www.federalregister.gov/documents/2015/ 10/22/2015 -24954/national-pollutant-discharge-elimination- system-npde s-electronic-reporting-rule . Electronic submissions must start by the dates listed in the "Reporting Requirements" section above. -DocuSigned by: Page 9 of 11 kiduld `— C464531431644 F E.. for Richard E. Rogers. Jr, Director Date: June 3, 2022