Loading...
HomeMy WebLinkAboutWM0501484_Application_20220524DocuSign Envelope ID: 6AAC3162-4DAB-46C8-BB13-F8A13i i 2 JMENTAL QUALITY - DIVISION OF WATER RESOURCES IYVR 1 1-1l VFIRV LIIYPI L/rF1R I IYICIY 1 .jr CIY vIRVI APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: 5/18/2022 2. County: Wake FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE 3. What type of well are you applying for? (monitoring or recovery): Temporary Monitoring Wells to be Abandoned After Sampling 4. Applicant: Geosyntec Consultants of NC P.C. as agent of The Halle Companies Telephone: 919-870-0576 Applicant's Mailing Address: 2501 Blue Ridge Road, Suite 430, Raleigh, NC 27607 Applicant's Email Address (if available): 5. Contact Person (if different than Applicant): Ryan Gabelman Telephone: 513-600-4585 Contact Person's Mailing Address: 2501 Blue Ridge Road, Suite 430, Raleigh, NC 27607 Contact Person's Email Address (if available): rabelman©geosyntec.com 6. Property Owner (if different than Applicant): Wal-Mart Real Estate Business Trust Telephone: Property Owner's Mailing Address: PO Box 8050 Bentonville, AR, 72716-8050 Property Owner's Email Address (if available): 7. Property Physical Address (Including PIN Number) 4401 Poole Rd, Raleigh, NC 27610, PIN 1733047524 City Raleigh County NC Zip Code 27610 8. Reason for Well(s): Environmental Site Assessment (ex: non -discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: Undeveloped Property (ex: non -discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or incident no(s). No 11. Type of contaminants being monitored or recovered (ex: organics, nutrients, heavy metals, etc.): Wells will be sampled to evaluate potential presence of Volatile Organic Compounds (VOCs) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? No. Existing Monitoring or Recovery Well Construction Permit No(s).: WM0501468 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): Possible LUST — 254 feet south of the Site 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? No. If yes, give distance(s): 15. Well Contractor: AmeriProbe, LLC — John Allen (Driller Certification No.: 4196-B Well Contractor Address: PO Box 135, Huntersville, NC 28070 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons c. Screen intervals g. Well head completion details d. Sand/gravel pack intervals DocuSign Envelope ID: 6AAC3162-4DAB-46C8-BB13-F8A1302DB072 cued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated 5. How will the well(s) be secured? Locking material: 5 expansion plug 3. Number of wells to be constructed in bedrock: 0 4. Total Number of wells to be constructed: 5 (add answers from 2 and 3) 6. Estimated beginning construction date: 6/6/2022 7. Estimated construction completion date: 6/8/2022 ADDITIONAL INFORMATION As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant hereby agrees that the proposed well(s) will be constructed in accordance with approved specifications and conditions of this Well Construction Permit as regulated under the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Digitally signetl by Ericp' { phapter 2C) and accepts full responsibility for compliance with these rules D N'. cnEric Riflcin, cU Eric Rifkin Halle Companies, ou=Assistant Vice emeaitleni mail=eriFkin©hallecom panies.com Date'. 2022. 05.23 14'.51'. 50-04'00' Signature of Applicant or *Agent Eric Rifkin Printed name of Applicant or *Agent Assistant Vice President Title of Applicant or *Agent * If signing as Agent, attach authorization agreement stating that you have the authority to act as the Agent. If the property is owned by someone other than the applicant, the property owner hereby consents to allow the applicant to construct wells as outlined in this Well Construction Permit application and that it shall be the responsibility of the applicant to ensure that the DDOM`L- nform to the Well Construction Standards (Title 15A of the North Carolina Administrative Code, Subchapter 2C). �lInG1 ktArt1Llgl, Walmart Real Estate Gina Meredith SignatureSignaturr glIsTiglty Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources' Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 �L It�l e."441 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 rx /44fi. fir Iriti%gton i GW-22M GW-22M (Rev. 5/11) DocuSign Envelope ID: 6AAC3162-4DAB-46C8-BB13-F8A1302DB072 Legend • Former Surface Water Sampling Leaking Underground Storage Tank Surface Water Direction Stream Surface Water Feature Proposed Temporary Monitoring Well Location Culvert Wetlands (unclassified) United States Wetland Inventory (wetland type) Freshwater Forested/Shrub Wetland Freshwater Pond Riverine Approximate Parcel Boundary Parcel Boundary Upgradiant' Notes: 1. Leeking underground storage tanks based on ERIS Figure. 2. Stream, culvert, and wetlands (unclassified) locations based on Figure 1 Surface Water Sample Location, S&ME dated 21 January 2020. 3. Surface water creek based on field observations December 2021. 4. United States (U.S.) wetland inventory data layer obtained from U.S. Fish and Wildlife Service Wetlands Mapper website (last modified 1 December 2021, North Carolina geodatabase). 5. Parcel boundaries obtained from Wake County North Carolina Open data site (5 January 2022, https://data.wakegov.com/). 6. 2020 World Imagery Source: Esri, Maxar, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GIS User Community. 0 200 Feet Trademark,Drive Proposed Temporary Monitoring Well Location Poole Road Multifamily Development Raleigh, North Carolina Geosyntec° consultants Geosyntec Consultants of NC, P.C. NG License No.: C-3500 and (', 295 Raleigh, NC May 2022 Figure 1 Path: (Titusville-01\DATA) T:\OGIS\GN8486_PooleRd\MXDs\SiteVicinity_wetlands.mxd 10 January 2022. Last Edited by: mhensley DocuSign Envelope ID: 6AAC3162-4DAB-46C8-BB13-F8A1302DB072 GROUND SURFACE 1" SCH 40 PVC RISER u- 7' BGS 9' BGS 10 FT. 1" SCH 40 PVC SCREEN (0.01" SLOT SIZE) n• END CAP TD=20' BGS LOCKING COMPRESSION CAP 7' GROUT TO SURFACE 2' BENTONITE SEAL 11' 20/30 SAND FILTER PACK NOTE: Total depth may be modified based on field conditions. BGS - below ground surface Grout will only be used if converted to a permanent monitoring well NOT TO SCALE MONITORING WELL CONSTRUCTION DETAILS Geosyntec Figure consultants Geosyntec Consultants of NC, P.C. 2 GN8486 May 2022